MAIN DISTRIBUTOR. There are also approved specialist distributors throughout the UK. APPROVALS



Similar documents
Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

Chapter 2 Basis of design and materials

Design Manual to BS8110

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Formwork for Concrete

DESIGNING STRUCTURES IN EXPANSIVE CLAY

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

symptoms of a faulty foundation

Pipeline design. concrete for life

FORM DESIGN. easy to work with, and generally available.

Understanding BS EN 771-3: Aggregate concrete masonry units

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

6 RETROFITTING POST & PIER HOUSES

HOUSE BUILDING DIGEST

Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

EXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL

Fire and Concrete Structures

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

High Strain Dynamic Load Testing of Drilled Shafts

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

King Post Wall Information

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Designed and Engineered to Perform

CE 366 SETTLEMENT (Problems & Solutions)

Cold Weather Concrete Practices

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Domestic Extensions. Monmouthshire County Council. Building control guidance document

Lighthouse Engineering, L.L.C.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

What is QuickBase? Traditional foundations (left) compared with QuickBase (right)

Design and Construction of Cantilevered Reinforced Concrete Structures

POST AND FRAME STRUCTURES (Pole Barns)

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS

Chapter 9 Remedial Measures

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

CONTENTS. Page KERBS ETHEKWINI PRODUCTS ETHEKWINI PRODUCTS WATER CHANNELS WATER CHANNELS / GRILL BLOCKS / CHANNEL DRAIN COVERS

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

How To Retaining Wall Guide

DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT

HOW TO DESIGN CONCRETE STRUCTURES Foundations

METHOD OF STATEMENT FOR STATIC LOADING TEST

SECTION EARTH MOVING

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

PDHonline Course S151A (1 PDH) Steel Sheet Piling. Instructor: Matthew Stuart, PE, SE. PDH Online PDH Center

Module 7 (Lecture 24 to 28) RETAINING WALLS

Foundations and Substructures

90 Brighton Road, Surbiton, Surrey

SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS

Aluminium systems profile selection

Soils, Foundations & Moisture Control

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

ATLAS RESISTANCE Pier Foundation Systems

GOOD NEWS BUT NOT ALWAYS

Post and Beam Construction

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

DAMAGE TO FOUNDATIONS FROM EXPANSIVE SOILS

Geotechnical Building Works (GBW) Submission Requirements

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

SECTION SHEETING, SHORING AND BRACING

Proposed Minimum Subterranean Termite Treatment Standards

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

J. & W. LOWRY LIMITED. This case study has been prepared for J & W Lowry Limited By Thomas Elliott Foster

Wisconsin Building Products Evaluation

Light compaction LT rammer

CHAPTER 6 CONSTRUCTION TYPES

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Wastewater Capital Projects Management Standard Construction Specification

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Hanson Building Products. precast basement solutions

SECTION SUPPORT OF EXCAVATION

Removable Aluminium posts

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

GUIDELINE FOR HAND HELD SHEAR VANE TEST

Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS

CHAPTER 2 QUANTITY TAKE-OFF

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Breakaway Walls

Page & Turnbull imagining change in historic environments through design, research, and technology

Transcription:

Section Clay Heave Protection is an EPS compressible-fill material which can be used to prevent potential problems in foundations due to moisture movement in soils which contain a large proportion of mineral particles below 0.002mm ( clay heave ). The material can be used as permanent shuttering for cast in-situ reinforced concrete, reducing pressure on ground beams in piled foundations, and on the sides of trench fills. Negligible compression during concrete casting With a normal ground-beam depth up to 600mm, the initial compression of the material during casting can be disregarded. Cost -effective provides a rapid, cost-effective solution to clay-heave problems, and no specialised trades or equipment are required. Permanent is rot-proof and durable and will withstand the conditions encountered below ground. It will not degrade in the presence of high levels of ground water or precipitation. Easy to handle is manufactured from expanded polystyrene (EPS), and is lightweight and easy to handle. The use of satisfies the recommendations of the Building Research Establishment (BRE), and the National House Building Council (NHBC) in using compressible materials to relieve clay-heave pressure. Table 7. Thickness of to comply with NHBC requirements Soil heave Underside of ground beam: Against side of foundations and beams: potential NHBC void equivalent VR NHBC void equivalent VR dimension (mm) (mm) dimension (mm) (mm) High 50 250 35 75 Medium 00 75 25 50 Low 50 00 0 0 MAIN DISTRIBUTOR is available through: Cordek Limited, Spring Copse Business Park, Slinfold, West Sussex RH3 0SZ Tel: 0403 799600 Fax: 0403 7978 There are also approved specialist distributors throughout the UK. APPROVALS There are no specific requirements in the Building Regulations for the use of compressible-fill materials. However, there is a general requirement (Regulation A2) which states that buildings shall be constructed so that ground movement caused by swelling, (or) shrinkage...of the subsoil... will not impair the stability of any part of the building. has been assessed by the British Board of Agrément according to Regulation A2, and found to reduce the effects of the expansion of clay soils which might impair the stability of a building. It has been approved for use under ground beams and against the sides of deep-trench fill foundations; Certificate number 90/2543. The NHBC Standards, Chapter 4.2, building near trees, states that low-density compressible polystyrene is a suitable proprietary material to alleviate ground pressures on foundations in shrinkable soils. GRADE is a special low-density expanded polystyrene. It is coloured pink for ease of identification. DIMENSIONS Standard size, 200 x 2400mm, and 600 x 2400mm. Thickness, 50, 75, 00, 50 and 200mm. Additional widths (eg, 400, 450 and 500mm) are also available. SHAPE Boards are normally rectangular and of uniform thickness, but special shapes are available to order including circular sections to fit around pile caps, and tapered boards. ACCESSORIES Spacing blocks to ensure correct cover to steel reinforcement must be of a type and quantity to prevent penetration into the surface of the ; the imposed pressure on the should not exceed 5kN/m 2. 54

Clay Heave Protection Figure 39. Protection of piled ground beam Reinforced beam Section Pile cut around pile cap 55

Section Clay Heave Protection FIRE When properly installed, the EPS is fully protected by the concrete beam or foundations and will have no adverse effect on the fire performance of the structure. MECHANICAL PROPERTIES The expansion of clay soil is a long-term phenomenon and it is necessary for the compressible fill to react in the same timescale. achieves this by creep deformation, reducing the induced pressures to safe levels. This value includes an allowance for instantaneous deflection of the due to the wet concrete load. NHBC requirements In order to comply with the NHBC requirements for building near trees, the thickness of shown in Table 7 should be provided on the underside of ground beams or against foundations or beams which are likely to be subject to soil heave. The design of beams, foundations and associated details should be in accordance with the requirements of the NHBC as set out in the relevant Standards. When designing ground beams which will support the weight of the building, care should be taken in areas of low load, for example under patio doors, to prevent excessive local deflection of the beam. must not be used under ground-floor slabs. is not designed for use DESIGN In order for Vencel Resil to provide advice on the appropriate thickness of for a given situation, the following information is required: directly below in-situ or suspended ground-floor slabs. Graph. compression curve. Maximum expected ground movement (H, mm). 2. Acceptable upthrust on the ground- beam foundation (P, kn/m 2 ) as used in the concrete design, or... 3. Maximum acceptable lateral thrust on the trench-fill foundation (W, kn/m 2 ); this value should not normally exceed 40kN/m 2. Transmitted Pressure (P or W) kn/m 2 40 30 20 0 The required thickness of can be calculated by reference to Graph. as follows: 0 0 20 30 40 50 % Compressive Strain C (%). Read-off the value for percentage compressive strain (C, %) given by the maximum load, P or W. 2. Calculate the required thickness of material by the equation T = 00 x H/C +0. thickness Compressed thickness at load P or W Specified thickness T (mm) T= 00H+0 C Predicted maximum clay heave H (mm) Compressive Strain C (%) 56

Clay Heave Protection Figure 40. Protection of deep trench fill Deep trench fill foundation below zone of movement Section (to maximum 2m depth) 500mm toe 57

Section Clay Heave Protection Loads exerted by wet concrete for 600mm-deep ground beams will result in negligible compression of the. For trench-fill applications, the concrete pour pressure should be limited to 36kN/m 2 to ensure that excessive initial compression does not occur; if necessary, this can be done by reducing the rate of pouring the concrete. The should be laid in the bottom of the trench, ensuring that the full width of the trench is lined and that the boards are butted tightly together. Where concrete piles protrude into the trench, the boards should be neatly cut to fit, or factory-cut sections should be employed. sides to ensure the correct depth of concrete cover is obtained to the steel reinforcement ; see ACCESSORIES, above. Alternatively, the vertical boards may be positioned after the ground beam has been cast. See Figure 42. INSTALLATION Piled ground beams The trench should be excavated as normal but taking account of the thickness of to be used. The bottom of the trench should be flat and even, and if necessary, be blinded with granular fill or concrete. The appropriate side of the ground beam, normally the inside face of an external wall, should be lined with, ensuring that the material is fully supported to the required depth. The must be adequately supported and restrained to prevent movement during concrete placement. Spacer blocks may be required at the Vertical faces of trench fill Care should be taken that the foundation bottom is below the zone of movement. The appropriate side of the excavation, normally the inside face, should be lined with, ensuring that the material is fully-supported to the required depth. Figure 4. Installing for piled ground beams Temporary support (removed as concrete is laid) The NHBC requirements state that a 500mm-deep concrete toe, the same thickness as the compressible fill, should be created below the boards. Any internal support must be provided in the form of struts and spreader plates. must be adequately restrained to prevent uplift during concrete placement. In flint or boulder clay soils, plywood sheeting may be required to provide external support to the. Concrete fixings Small pieces of must be securely fixed prior to pouring. See Figure 4. 58

Clay Heave Protection Section Figure 42. Deep trench fill. 2. Deep trench fill foundation below zone of movement 3. 500mm deep concrete toe 2 3 Figure 43. Piled ground beam. 2. Piled ground beam 3. Pile 3 2 59 0