1 Ground workers handbook Foundations and Substructures
2 Introduction The Ground Workers Handbook gives guidance to site managers and site staff on any particular issues on your site for traditional forms of construction. Rafts, piles, ground beams and suspended reinforced concrete floors are not covered by this guide. For these types of construction, a structural engineer should be consulted. Ground and site conditions can vary significantly and although this guide gives examples of the most commonly occurring issues, LABC New Home Warranty recommend early contact with our surveyors to help give guidance on how to avoid particular circumstances on your site. Please refer to the LABC New Home Warranty Technical Manual for the Functional Requirements, Principal Performance Standards / Requirements for the design and construction of Housing units using LABC New Home Warranty. Please note: there are Statutory variations to the information shown in this publication in respect to: England and Wales: The Building Regulations 2000 (as amended) and Approved Documents. Please refer to your LABC New Home Warranty Site Audit Surveyor for further advice. Your LABC New Home Warranty Site Audit Surveyor contact is: 1
3 ContentS Key to successful foundation construction 3 Soils 5 Foundation depths 6 Japanese knotweed 7 Trees and hedges 8 Heave precaution 10 Setting out 12 Foundation Excavations Foundation dimensions 13 Stepped foundations 14 Filled ground hazards 15 Water and debris in trenches 16 Surge from adjacent foundations / structures / drains 17 Construction joints 18 Plastic shuttering 19 Substructure Setting out of walls 20 Sloping sites 21 Drainage and services entries 22 Oversite fill below ground bearing floor constructions 25 Prevention of heave under ground bearing floor slabs 27 Damp proof membranes 28 Ground bearing concrete floor slab 31 Suspended floor constructions 32 Horizontal damp proof courses 34 Level access requirements 35 Radon and gas barriers 39 Notes 40 2
4 Key to Successful Foundation Construction Site investigations must be undertaken to reveal the likely ground conditions of a site. These findings assist the Architect and Engineer to design the most appropriate foundation for the building. To avoid damage to the building, the foundation design will have to take account of: Soil types. Clay soils and the potential for movement caused by shrinkage and swelling is a particular problem near trees (1) and also preventing damage due to frost or prolonged periods of hot weather. (2) Movement due to the presence of made ground or consolidation of poor ground. (3) Movement due to nearby excavations. (4) Erosion of the soil particles due to water in the ground e.g. leaking drains. (5) Underlying strata e.g. thin bands of sandstone with weak mudstone under. (6) 3
5 Case Study: Movement due to nearby trees Trees were removed at the time of development, including a row of conifers 6m away from the elevation shown. Other unspecified tree(s) were also removed from within the building footprint. Re-hydration of the clay is now occurring, causing heave movement. A site and ground investigation is required for warranty purposes to identify any geotechnical or contamination hazards present on or adjacent to the site that might adversely affect the housing unit. The investigations will also alert the design team to: Past use of the site. Instability of sloping ground. Mining subsidence. Chemical attack on the foundation concrete. Contamination hazards. Methane and landfill gases. Radon. 4
6 Soils Natural soils encountered usually fall into one of the following categories: Fine grained cohesive soils, (clay and plastic silts) Changes in the moisture content of cohesive soils commonly occurs as a result of seasonal changes in the weather or from the influence of existing or removed trees. This can result in shrinkage or heave in the ground. If foundations are not deep enough or anti-heave measures are not adopted, movement of the foundations and floor slabs may take place. Course grained granular soils (sand, gravel, and non-plastic silts) Granular soils usually provide a good founding medium and in their dense state can accommodate heavy foundation loads from large structures. However, problems can arise when they are encountered in a loose condition or where high groundwater levels are present. In these cases a structural engineer should be consulted. Rock (chalks, sandstone, shale and other natural bedrock) Rock strata can provide a good founding medium and may accommodate very high foundation loads. However, hazards may exist and a thorough site investigation should be undertaken to identify these in advance. Such hazards include: Natural or man-made cavities. e.g. mine workings. Thin layers or crusts of rock strata may be overlaying a weaker ground. Note: where proposed building works are to be founded on chalk, a structural engineer must be consulted to fully investigate the ground conditions, in particular for susceptibility to dissolve into solution by groundwater with the resultant voids. It is also common to encounter more than one soil type. Soils can vary both across the site and also with depth. Such circumstances will require special foundation measures to be taken and a structural engineers design should be used. 5
7 Foundation Depths The required depth of the foundations can be influenced by a number of factors. However, in general terms, the minimum depths should be the greatest of the following criteria: The depth to the selected bearing stratum. In clays which are subject to seasonal moisture movement, not less than 1.0m in depth (see also BS 5837). In clays and in close proximity to trees and shrubs (see sections on Soils and Tress and Hedges). In sands, chalk and other frost susceptible soil, a depth below the zone of frost action and not less than 450mm (on exposed sites subject to long periods of frost, an increase in depth will be required). For internal load bearing walls, foundations must be provided to the same depth as the external walls. For minimum widths of strip foundations refer to Building Regulations. Not all natural soils lend themselves to conventional spread foundations. Also, spread foundations may not be the most cost effective solution. Other foundation methods may be appropriate and should be determined by an Engineer. These may take the form of one of the following: Pile and ground beam. Pad and ground beam. Rafts. Vibratory ground improvement. Engineered Fill. On Brownfield sites, natural soils are often concealed beneath man-made ground or ground that has been reworked. Care therefore needs to be taken to ensure that the level of the natural soils (i.e. virgin strata) is correctly identified for foundation purposes. Man-made ground may also pose a risk from contamination. 6
8 Japanese Knotweed Reproduced by kind permission of the Environment Agency Detection of Japanese Knotweed must be undertaken before any site clearance is undertaken on a new development (or an existing site subject to refurbishment). Japanese Knotweed forms in dense clumps up to three metres in height. It has large, oval green leaves and a stem that is hollow and similar to bamboo. This plant can grow as much as 2cm per day and will grow in any type of soil, no matter how poor. Clusters of cream flowers develop towards the end of August. The plant is hazardous to building works and due to the depth and virulence of the roots, has the potential to cause structural damage. All Developers should seek specialist advice before attempting to remove the vegetation. For further information refer to: Environment Agency publication The Knotweed Code of Practice on 7
9 Trees and Hedges Regardless of whether the trees, hedges or large shrubs are within the site boundary or on adjacent land, if they are young or mature in age or have been recently removed; it is likely that they can have an influence on clay soils about the new building. Trees extract moisture via the root systems from depths typically greater than 1.5m and potentially to 5m. Where buildings are to be constructed on clay soils, within the influence zone of the trees (or removed trees) piled and beam foundations are recommended. However deepened trench fill foundation may be used subject to careful design which takes account of the swelling of the soil. A structural engineer should be engaged to provide a specification for foundation depths based on the tree varieties and the soil types. This may influence your choice of foundation design. Consideration must also be made for: Underlying clay soils existing below a sand / gravel soil dig level. Potential effect on buildings from new tree planting on site. Location of former trees and shrubs. To establish the correct depth of foundations, the following documents should be referred to: BSEN :2004 Geotechnical design. General rules / BS 8004: Code of practice for foundations. BS 8103: 1995 Part 1 Code of practice for stability, site investigation, foundations and ground floor slabs for housing. BS 5837; Code of practice for trees in relation to construction. BRE Digests; 240, 241, 251 and
10 Case Study: It is not just trees that require careful consideration near the building works; hedgerows particularly confers, can have an adverse effect on the ground adjacent to the building works. Case Study: Tree roots found in the bottom of the trench indicate the excavations are not deep enough to avoid the potential for causing movement and subsequent damage to the building. 9
11 Heave Precautions Deep trench fill foundations in clay soils within the zone influence of trees will require protection from vertical and lateral clay movement on the sides of the foundations, substructure walls and under the ground floor construction - even if the trees have been removed. Compressible materials or void formers should be correctly placed to absorb the swelling of the clays. only products with third party accreditation should be used. The thickness of the vertical compressible material T must be sufficient to absorb the expected swelling of the soil (to be determined by the Structural Engineer). The sides of the foundation must be vertical and not battered at an angle. Floors; where clay soil movement is likely, a suspended ground floor construction should be used with a void formed under (Note: The depth of void must not be less than 150mm to accommodate the heave potential of the soil, seek advice of a Structural Engineer). Note: Polystyrene sheet should not be used under a cast in situ concrete floor as it may transmit the swelling pressures to damage the floor. 10
12 The compressible material must be positioned and held in place on the vertical inside face of the foundation starting 500mm above the bottom of the trench and for the full length of the affected foundation. A Polythene slip membrane is recommended to the vertical outside face of the foundation to reduce uplift forces caused by swelling soil. Case Study: Heave precautions to the inside face of the foundations should have been incorporated prior to concreting. 11
13 Setting Out Excavations must be kept straight and level. Check that the designed thicknesses of leaves of walls and correct cavity width will be provided. The substructure will be constructed centrally on the foundations. Check diagonals and all structural measurements carefully. Check latest plans for correct specs and planning approvals for any conditions attached relating to positioning of buildings. This includes; finished floor levels, ground levels and correct construction of entrance ramps and driveways. Also positions in relation to tree preservation orders. 12
14 Foundation Excavations Foundation Dimensions Concrete Strip Foundation Wall to be central on foundation. Minimum thickness of foundation concrete (T) to be (P) or 150mm which ever is greater. Foundations must be widened at piers and chimneys to maintain a projection dimension (P). Foundation width (FW) to be not less than the recommendations in the Building Regulations approved Document. Unless structurally designed, where concrete is cast directly against the earth, any reinforcement used must have at least 75mm nominal cover. The trench bottom of each foundation length must be horizontal (and to each stepped length). The face of each step where provided, must be vertical. 13
15 Stepped strip Foundation Minimum overlap L = 2 x S or = thickness of foundation or = 300mm which ever is the greater S must not be greater than T Stepped Trench fill Foundation Minimum overlap L = 2 x S or = 1 metre which ever is the greater D to be 500mm minimum 14
16 Filled ground Hazards Case Study: Seemingly good virgin sites (same site as previous picture) can have hidden pockets of fill / ash pits /soak ways. The foundation excavations must be stepped down to at least 300mm below the invert of the fill on all lengths of trench likely to be effected. Case Study: Evidence is available to be seen in the sides of an excavation to alert the presence of filled ground and drains. This excavation had to be deepened by a further 1.2m due to an existing drain below. 15
17 Water and Debris in Trenches Case Study: Any water and loose material collecting in the trench bottom must be removed. Sumps should be formed (not located at returns) and the water pumped away from the excavation area. Immediately prior to concreting, the trench base must be scraped to remove any softened clay / slurry to ensure the concrete is placed on firm as dug material. This is particularly important where the mechanical excavator with a toothed bucket has been used. standing water between the grooves in the trench bottom can potentially soften the clay. If the trench bottom has been left for some time and has dried out and / or cracking appearing in the clay, the trench should also be bottomed up by excavating the trench width by a further mm depending on the conditions. Where a trench has been left open for a considerable length of time an engineer s advice should be sought before continuing with the construction works. 16
18 Surge from adjacent foundations, structures and drains Where a foundation adjoins an adjacent foundation or service trench, the layout shown in the detail below should be followed (unless specialist engineering advice is taken). Foundation adjoining a trench The zone of loading below the new foundations should not fall within the excavation area of the lower trench. Where A is less than 1m, the lower trench must be back filled with concrete up to the lowest level of the adjacent higher trench. Case Study: Particular care must be taken with new works on a sloping site where excavations for adjacent plots could be undermined or at risk particularly if strip foundations rather than trench fill methods are being adopted. Precautions must also be taken when constructing new works adjacent to existing buildings where for example a cellar may exist. 17
19 Construction joints The following methods may be considered for strip and trench fill foundations only. Any other arrangement should be engineer designed. Strip Foundation The reinforcing bars should be at least 1 metre long projecting 500mm either side of the shutter. Typically 2 no, T16 or T20 bars used. Trench Foundation The reinforcing bars should be at least 1 metre long projecting 500mm either side of the shutter. Typically; 2 no; T16 or T20 bars used for every 150mm depth of concrete. Notes: The concrete pour should ensure a consistent depth of concrete (150mm minimum). 18
20 Construction or day joints should always be avoided where possible. If however a construction joint is to be formed, it should be positioned and constructed along the line of excavation, not near a return. Ideally, corrugated shutter boarding should be used. Any remaining lengths of foundation should not be excavated, or the formation should be blinded with concrete to prevent it from softening. Plastic Shuttering When using plastic shuttering for ground beams, care must be taken to ensure the shuttering is properly supported by the backfill material prior to the pour of concrete. The shuttering must be kept straight to ensure the correct depth of cover to the reinforcement will be achieved. 19
21 Substructure Setting out of walls The Foundations must be the correct width to accommodate the walls centrally. The concrete foundation must be level. The diagonals must be checked before constructing the substructure walls. Masonry should be set out to achieve correct cavity widths. Initial cavity widths may require increasing to allow for timber frame sheathing panel projections (Timber framed superstructures). Brickwork set to the edge of the foundation trench or corbelled in order to rectify cavity widths must be avoided. 20
22 Sloping Sites Depth of infill on sloping sites A sloping site may require steps in the floor levels of the housing unit and terracing of the external ground levels. As a consequence, the depth of fill material below the floor could exceed 600mm and require a suspended floor to be constructed. Thickness of walls below DPC level on sloping sites As a result of the slope of the ground, the substructure walls may also act as retaining walls. A structural design must be provided: a) to assess the compressive strength of the masonry below DPC level, and b) if the retained height of the wall H exceeds the following; Clear cavity: H should be less than or equal to 1m and less than 4 x (T1 + T2) and wall ties must be provided Note: If the cavity wall is filled with lean mix up to the retained height level H. H should be less than or equal to 1m and less than or equal to 4 x total thickness of the wall (T). 21
23 Drainage and Service Entries Drains and services passing through the external (and internal walls) must be protected from damage by the use of lintels or rocker pipes. Case Study: Excessive lengths of openings formed must be avoided. 22
24 Reinforced Concrete Lintels should be used over the opening on each structural leaf with a minimum 150mm end bearing. Do not use metal lintels below the ground level. A minimum 50mm space around pipes should be provided. Lintel Opening Openings should be sealed with a suitable board (for underground use) both sides to prevent vermin access. Rocker Pipe Construction 600mm Max 600mm max mm Max 150mm max 150mm Max 150mm 600mm max max mm Max 23
25 Where drains are built into the wall construction, flexible joints (rocker pipes) must be provided as shown. Case Study: Plastic drains must have equal provision for movement and must not be built in solid. Case Study: Inspection chambers should not be sited so close to substructure walls that lintels and large voids are created in order to bridge the chamber construction. Note: the horizontal DPC was also found to bridge the cavity without a suitable cavity tray installed 24
26 Oversite fill below ground bearing floor constructions Topsoil and organic matter (including roots) must be removed and the resulting underlying layer must be level and provide a consistent bearing surface. The ground floor slab must be constructed on a minimum 150mm of inert well graded fill material, such as crushed stone or other suitable fill, blinded with fine material. The fill material should be compacted in layers not greater than 225mm thick and should not contain any pieces that will not pass through a 75mm diameter ring. Where the total depth of any infill under the slab (including the foundation trench area) exceeds 600mm, a suspended floor construction must be provided. Fill material should be free from harmful toxic substances and be of a type of material that will not result in expansion of the hardcore that would cause distress to walls and or the floor structure. Fill material should be certified by a competent laboratory as to their fitness for purpose. They should be chemically analysed to check if they contain any contaminants (e.g. pyrite). Where sulphates are present in the ground, the concrete mix must be able to resist sulphate attack and a suitable protecting layer of 1200gauge polythene provided. Case Study: Topsoil and vegetation must be removed from the area forming the floor footprint. 25
27 The maximum individual layer thickness of filled material should not exceed 225mm and be properly compacted. Maximum total depth of the filled material layers, should not exceed 600mm under the slab and the foundation trench areas. Concealed chambers, manholes or soft localised pockets of fill under slab areas should be removed. a suspended floor may be required. Case Study: Uncontrolled and excessive areas of fill. A suspended floor construction is the only solution in this situation. 26
28 Prevention of Heave under ground bearing floor slabs There are four potential areas of concern; 1) Where ground recovers due to removal of load e.g. substantial excavations of soil to create basements (commonly called removal of overburden). 2) Swelling of Clays (including movement caused by trees). 3) Frost heave. 4) Chemical reaction e.g. Sulphates or pyrites in infill material. 1) Overburden: occurs in both granular and cohesive soils. A structurally designed foundation is recommended e.g. piles, to allow the soil to swell without effecting support to the building and provide a suspended floor construction with a void under. 2) Swelling of Clays: where preventative measures are deemed necessary for the foundation design, a suspended floor construction is recommended with a void formed under. 3) Frost Heave: mainly occurs on very exposed sites. ensure foundations are dug to at least the minimum depths described in the Foundation Depths section of this book and avoid leaving the reduced levels exposed for long periods during freezing weather prior to construction of floor areas. 4) Chemical reaction: avoid Sulphate attack on concrete from potential contaminants in the soil or back fill material. Appropriate testing must be carried out on suspected soils and imported fills. Shale, brick rubble with attached plaster must not be used. Fill material must also be checked for containing pyrites. The concrete used in the foundations and floor should be an appropriate mix to resist sulphate attack. 27
29 Damp Proof Membranes Ensure the hardcore infill is well compacted and is covered with sand blinding to provide even support for the insulation / DPM. Membranes to be not less than 1200 gauge. The thickness may have to be increased if a Radon or other gas barrier is required. Additional provisions for laps / service pipe penetrations also apply. DPM sheets must be overlapped by min 150mm. it is recommended, that all laps in DPM are taped or sealed. Where the DPM is sited below the concrete slab it should also be below any insulation level if that insulation material is not resistant to ground contaminants. The DPM must be turned up at slab edge and be lapped under the DPC for the full thickness of the inner leaf to form a continuous barrier. Where ground floors and walls fall below the external ground level (e.g. stepped layouts on sloping site, semi or full basements), normal DPM s will not be adequate. A third party approved tanking system should be used and the design should follow recommendations in BS
30 Service Pipe entries through ground floor constructions Ensure the DPM is properly installed around pipe area and all joints sealed. Cut the main membrane tightly around the service pipe. Form additional seals with off cut squares of membrane in the form of a collar or top hat. This should be lapped and sealed to the main membrane with adhesive jointing tape (Proprietary top hat sleeves are available for this purpose). Note: Where Radon Barriers are required, additional measures will be necessary. 29
31 Case Study: The edges of the DPM, insulation and DPC must be protected with a temporary timber board (or other durable material) during construction to prevent damage when tamping or power floating the floor slab or from general construction traffic (especially at door openings). Ensure that the correct perimeter insulation is in place and that sufficient overlap of DPM is provided to lap under the DPC for the full thickness of the inner leaf to form a continuous barrier. 30
32 Ground Bearing Concrete Floor Slabs The appropriate mix for concrete slabs should meet BS EN / BS 8500 standards. Ensure a DPM is provided and lapped to the DPC. Note: where insulation slabs are sited below the concrete slab: They are supported off a compacted sand blinded base. Insulation slabs must be butted together to avoid sections of concrete cold bridging against the ground - and avoid potential cracking occurring in the floor above. Ensure the perimeter insulation is in place and taken up to screed level (if provided). Unreinforced concrete ground bearing slabs must not be less than 100mm thickness. Unbonded screeds; minimum thickness 65mm see BS :2003. Case Study: Inadequate thickness of concrete will lead to cracking. 31
33 Suspended floor constructions Where designed and third party approved precast concrete beam and concrete block construction is proposed: It is preferable (to prevent water ponding) to raise the ground level below the floor ( Solum ) to match that of the external ground levels (assume level site) and position the beams and blocks above DPC level. There must be at least 50mm space between the underside of the floor beams and the ground level below. The beams must be placed onto a DPC at the bearings. Ensure 90mm minimum bearings of the beams and blocks onto supporting walls. Ensure the cavity fill material is 225mm below the lowest DPC level. The upper surface of the beam and blocks are grouted with a 1:6 cement sand mix. Ventilation at two opposite walls must be provided to the floor void with a recommended provision of 1500mm2/m run. Beam and Block Construction below DPC level 32
34 Where the ground level below the floor is below external ground level and not effectively drained; A DPM must be provided above the beam and block and linked to the wall DPC. Provide a blinded Solum laid to a fall to an external elevation wall with appropriate vermin proof piping through the wall to a land drainage system externally. Beams ready to be set out to correct spacing s on top of DPC. Telescopic Ventilators in position ready for outer leaf to be built. 33
35 Horizontal Damp proof courses The DPC must be positioned not less than 150mm above the finished ground level (including paviours). The top of the lean mix cavity fill material must be at least 225mm below the lowest DPC level. The DPC must be laid on a mortar bed in a continuous length for the full width of the leaf (including an external render finish unless a bell mouth stop provided). The DPC must not bridge the cavity (unless forming part of a cavity tray). The DPM must lap under the DPC for the full thickness of the leaf. Case Study: Where a damp proof membrane (and / or gas barrier) is to be sited above the floor construction, but not laid until the superstructure is completed or the floor screed installed, it is appropriate to install a 450mm wide DPC lapped onto the inner leaf prior to the walls being constructed. This allows a lapped and taped installation with the DPM at a later date. In the photo, the inner leaf DPC is not the full width of the block. 34
36 Level Access Requirements Ramp and Landing area The construction of the access landings and ramps must not compromise the DPC in the walls See Building Regulations for disabled ramp design and landing dimensions. Ramps should not exceed 1:12 gradient. Where the outside ground levels slope towards the property, an effective gulley system should be provided to prevent flooding, e.g. in front of garage doors. Case Study: Measures to drain surface water from access door landings are required: The landing should be laid to a 1 in 60 fall away from the door. The drainage channel should discharge to an outfall, e.g. storm water drain system or a suitable soak away. 35
37 Level Threshold Construction Case Study: Poor detailing of the floor slab construction at the door threshold position has resulted in a potential cold bridging issue (Note, there is also a lack of a correct horizontal DPC blue bricks should not be used as the sole means of preventing damp). Case Study: Threshold constructions must have adequate DPC s and thermal breaks to avoid cold bridging. 36
38 External Wall Level Threshold Solutions Ground bearing concrete floor construction, timber door sill. Suspended ground floor beam and block, pre cast concrete sill. 37
39 Sill and Lower Threshold Requirements Note: where timber sills are installed, to prevent deterioration of the timber due to the risk of moisture ingress, a drained and vented void must be provided immediately in front of the sill (at least 125mm invert). The following dimensions should be observed to ensure an almost level threshold but provide reduced risk of moisture ingress. Proprietary drainage channels must be connected to a suitable outfall (storm drainage system or soak away if ground conditions permit). Please refer to current Building Regulations for guidance in respect of; damp proofing, thermal bridging, sub floor ventilation and further disabled access requirements. (reference to Accessible thresholds in new housing is made in Approved document M). 38
40 Radon and Gas Barriers Only third party accredited materials must be used. Additional measures to extract the gases from the substructure such as sumps and associated pipework should be provided. All joints must be correctly lapped, following the manufacturers instructions (gaffer tape is not acceptable). Service entries require special attention. Detailing at cavity wall bridges must ensure membranes are carefully supported. Case Study: Gas barrier where exposed must be protected from damage. 39
41 Notes: 40
42 Notes: 41
43 Notes: 42
44 Haymarket Court Hinson Street Birkenhead Wirral CH41 5BX T F E enquiries@labcnhw.co.uk W MD Insurance Services Ltd. is the Scheme Administrator for the LABC New Home Warranty. MD Insurance Services Ltd. is authorised and regulated by the Financial Services Authority. MD Insurance Services Ltd. is registered in England No: : m :1 0 10mm
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
More informationCavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
More informationImproving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
More informationSoils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationGuide to working on Public Sewers
Guide to working on Public Sewers affected by Building Works Introduction Severn Trent Water Ltd requires the work to be done in order to protect the public sewer and minimise the risk of us having to
More informationCHAPTER 2 QUANTITY TAKE-OFF
CHAPTER 2 QUANTITY TAKEOFF The quantity takeoff is an important part of the cost estimate. It must be as accurate as possible and should be based on all available engineering and design data. Use of appropriate
More informationResidential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
More informationStandards Committee T echnical Technical Conference
Standards Committee Technical Conference Agenda Overview of claims costs Years 0 2 claims and resolutions Years 3 10 claims What are we commonly seeing now? An example of what we might see in future? Summary
More informationThe better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
More informationDomestic Extensions. Monmouthshire County Council. Building control guidance document
Monmouthshire County Council Building control guidance document Domestic Extensions Building Regulations 2010 (with 2013 amendments) For use in Wales May 2013 Edition Guidance produced for Monmouthshire
More informationRESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use
More informationINTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
More informationInvestigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps
Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure
More informationFoundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
More informationEXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS
NMP 1.4 EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS Index Purpose... 2 Application... 2 Referral Agency... 2 Associated Requirements... 2 Referenced Standards...2 Definitions...
More informationSimplifying design and construction. Alan Tovey, Director The Basement Information Centre
Simplifying design and construction Alan Tovey, Director The Basement Information Centre Simplifying design and construction Grades of construction Construction options Design and waterproofing issues
More informationChapter 5.4. Waterproofing of basements and other below ground structures
Chapter Waterproofing of basements and other below ground structures Waterproofing of basements and other below ground structures CONTENTS SCOPE DESIGN Clause Page D1 Design standards D1 2 D2 Statutory
More informationUniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection
Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008 Foundation Heave Protection The safe, sure way to provide foundation protection Clayshield is the proven solution to protecting foundations against
More informationCHAPTER 6: SUBSTRUCTURE
CHAPTER 6: SUBSTRUCTURE Technical Manual V7: TS-011a-7.00-180814 CHAPTER 6: SUBSTRUCTURE CONTENTS 6.1 BASEMENTS 6.2 WALLS BELOW GROUND 6.3 DAMP PROOFING 6.4 GROUND FLOORS 89 CHAPTER 6 FUNCTIONAL REQUIREMENTS
More informationChapter 2 Basis of design and materials
Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural
More informationHOUSE BUILDING DIGEST
HOUSE BUILDING DIGEST (Construction Specifications-Foundations) Creating Enabling Environment for Affordable Housing for All This is an attempt by BMTPC to provide useful but often ignored information
More informationTECHNICAL MANUAL. New Homes
TECHNICAL MANUAL New Homes V2 Contents Part 1...5 Introduction and statutory requirements...5 General introduction, layout and use of the manual....5 Functional Requirements...6 Compliance with Building
More informationContents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
More informationWhat you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
More informationDesigned and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
More informationHouse building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors
W42_Stand_Extra_32 15/3/05 9:17 am Page 2 NHBC s technical newsletter April 2005 Issue 32 This edition includes: 2 House building is changing fast NHBC unveils new Standards Chapters on curtain walling
More informationDESIGNERS GUIDE TO DOMESTIC CONSERVATORIES
WBCA 403 DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES A guide to assist those intending to install or who are involved in installing conservatories. Includes information about: conservatory and component
More informationCW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS
December 2014 CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications...
More informationRochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture
Rochdale Building Control Guide Approved Document C Site preparation and resistance to contaminants and moisture Dampness is often misdiagnosed within buildings, the approved document deals with prevention
More informationSECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
More informationCITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT
Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide
More informationChapter 9 Remedial Measures
[This is an annotated version of a chapter from the US Army Corps of Engineers book, Foundations in Expansive Soils. This book is in the public domain. This document is consists of an abbreviated and annotated
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationSECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
More informationResidential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
More informationLighthouse Engineering, L.L.C.
Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: Office@LighthouseEng.com Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering
More informationSikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
More informationA guide to preventing structural damage
A guide to preventing structural damage Home owners guide to planning landscaping and maintenance of foundations Structural damage can result from movement in clay soils caused by varying moisture conditions
More informationARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057. Lecturer: Jim Cahill
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057 Lecturer: Jim Cahill 29 th November 2011 TABLE OF CONTENTS SUMMARY 1 MAIN BODY SECTION
More informationThe Guide To Waterproofing An Existing Basement
The Guide To Waterproofing An Existing Basement John Newton & Company is the leading independent supplier of basement waterproofing and damp proofing solutions in the UK. Newton System 500 is a maintainable
More informationR E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
More informationSchool Construction Authority Architecture & Engineering
SCOPING GUIDELINES 1.0 GENERAL GUIDELINES 2.0 BUILDING ENVELOPE SCOPING GUIDELINES 3.0 CATEGORIES AND COMPONENTS: The Flood Elimination/Below Grade Capital Category may include some or all of the following
More informationBUTE Department of Construction Management and Technology
BUTE Department of Construction Management and Technology 02.10.2012 Definition 1: Foundation: The structure, that transmits the load of the building to the soil Definition 2: Load bearing soil (strata):
More informationThe Effects of Trees On Buildings And Their Characteristics - Part 2
TECHNICAL NOTE NO. 3 TREES AND THEIR EFFECTS PART 2 Part 1 discussed tree and soil characteristics. This Part 2 will provide examples of the effects of trees on buildings with some guidance on defects
More informationPrepare a drainage system layout and specification notes for a low- rise building.
STUDENT MATERIALS Prepare a drainage system layout and specification notes for a low- Outcome 1 - rise building. In this outcome you will study the technology of below and above ground drainage systems.
More informationWET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.
WET/DAMP BASEMENTS PROBLEM. IS THIS BASEMENT LEAKING OR COULD WE HAVE ANOTHER PROBLEM? Water line arching up on wall in corners of basement. Water collecting on concrete floor starting in corners. ANSWER:
More information201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE
STRUCTURAL INSPECTION REPORT DRAFT 201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE TOWN OF PRESCOTT Date: November 2013 GENIVAR No.: 131-20617-00 2611 Queensview Drive, Suite 300, Ottawa,
More informationSiting and settlement: The most important way to protect shelter from floods is to build in a place that is unlikely to be flooded.
Siting and settlement: The most important way to protect shelter from floods is to build in a place that is unlikely to be flooded. Key Messages Shelters and settlements should be sited above the highest
More informationBasement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
More informationIntroduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References
Introduction General This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will
More informationHow To Prevent Water From Getting In A Building
ISSUE 1 Basement conversions Japanese Knotweed Weep holes in rendered cavity walls Level thresholds Canopy Flashings & Weathering Details Lightning protection systems To promote high standards of construction
More information9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES Hunter Underground Systems 9.01 General 9.02 Surface water Drainage 9.03 Groundwater Drainage 9.04 Dispersal of Septic Tank Effluent 9.01 The use of
More informationWhat is QuickBase? Traditional foundations (left) compared with QuickBase (right)
QuickBase is an innovative new foundation and floor system for conservatories and lightweight structures which was launched in prototype form at last year s Interbuild exhibition, where it was hailed as
More informationThe Manitoba Water Services Board SECTION 022180 Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11
Page 1 of 11 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the excavation of trenches (or excavation of tunnels); the supply and placing of bedding and backfill materials;
More informationSTEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.
STEP-BY-STEP construction guide Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. Welcome to our CONSERVATORY AND SUNROOM CONSTRUCTION GUIDE What is the specification
More informationSECTION 31 20 00 EARTH MOVING
SECTION 31 20 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for excavating, filling, and grading for earthwork at Parking Structure, new exit stair and as required to
More informationThe minimum reinforcement for the stem wall is the placement of:
PolySteel creates an ideal insulated stem wall for concrete slabs that can make this part of your project easier and faster, in addition to making your finished project more energy-efficient. Figures 3.20
More informationSafe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
More informationElevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
More informationEAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
More information6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
More informationBUILDING OVER OR NEAR WATER & SEWER MAINS POLICY
MURRAY SHIRE COUNCIL BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY ADOPTED: 1 May 2012 1 BUILDING OVER OR NEAR WATER AND SEWER MAINS POLICY CONTENTS 1. Objective... 2 2. Requirements for Building Near
More informationBasement Waterproofing in Existing Buildings
A S S O C I A T I O N Basement Waterproofing in Existing Buildings A guide to protecting your home Follow us on Twitter Find us on Facebook www.property-care.org A basic understanding of Basement Waterproofing
More informationConcrete Waterproofing Systems. Integral Protection. www.tritonsystems.co.uk
Concrete Waterproofing Systems Integral Protection n Type B Integral Protection in accordance with BS 8102 (2009) n Unique chemical admix for waterproofing and protection of concrete n A complete and permanent
More informationImproving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.
Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
More informationSubcontractors Typical Sample - Groundworks Priced Bill of Quantities. Labour & Plant Groundworks. Ref Description Quantity Units Rate Sub Total
Subcontractors Typical Sample - Groundworks Priced Bill of Quantities Labour & Plant Groundworks Ref Description Quantity Units Rate Sub Total Excavating trenches; to receive pipes not exceeding 200 nominal
More informationSPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)
Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks
More information1. Safety. 2. The Lining Contractor. DEPARTMENT OF AGRICULTURE, AND FOOD Farm Development Service November 2002 S126
DEPARTMENT OF AGRICULTURE, AND FOOD Farm Development Service November 2002 S126 MINIMUM SPECIFICATION FOR GEOMEMBRANE-LINED SLURRY/EFFLUENT STORES, AND ANCILLARY WORKS This is a minimum specification.
More informationEXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
More informationHIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
More informationServices Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
More information0331 Brick and block construction
0331 BRICK AND BLOCK CONSTRUCTION This worksection has been written for Class 1 and 10a buildings that fully conform to the scope of AS 4773.1. If the works include isolated structures, (totally separate
More informationMUNICODE SERVICES LTD.
The Preserved Wood Foundation Guide MUNICODE SERVICES LTD. Prepared by MuniCode Services Ltd. Outline and Restrictions of this Guide The following information required for the construction of Preserved
More informationbout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions
A bout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions CE 28 b Ground slopes towards window well No granular fill or connection to footing drain Ground floor
More informationDimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05
Dimensional and Structural Data for Elliptical Pipes 21/09/05 Page 1 of 15 1. Foreword This document details a method for the structural design of Stanton Bonna Elliptical pipes for the common conditions
More informationSPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
More informationInstallation PowerPoint for Grasscrete Formers
Installation PowerPoint for Grasscrete Formers 1 This document describes the two single-use tools utilized to create the Grasscrete product. The original Former is a vacuum formed light gauge plastic mold
More informationStormwater/Wetland Pond Construction Inspection Checklist
: Construction Inspection ChecklistsTools Stormwater/Wetland Pond Construction Inspection Checklist Project: Location: Site Status: Date: Time: Inspector: SATISFACTORY/ UNSATISFACTORY COMMENTS Pre-Construction/Materials
More informationAttachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits
Attachment G-1: Pit Latrine Diagram Fig E.1a: Pit Latrine Fig E.1b: Plan View of Twin Pits Fig E.1c: Section of a water-sealed pan Fig E.1d: 3D view of Overflow Pipe Fig E.1e: 2D view of Overflow Pipe
More informationSeptember 2007. September 2013. Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. info @ akt-uk.com www.akt-uk.
Consulting Structural and Civil Engineers 100 St John Street London EC1M 4EH T +44 (0) 20 7250 7777 F +44 (0) 20 7250 7555 info @ akt-uk.com www.akt-uk.com 3290 A031234 The 196-222 Joseph Kings Bloggs
More informationCold Weather Concrete Practices
Cold Weather Concrete Practices The Information below is an outline of common practice for residential foundation placement and winter construction utilize Edmonton and surrounding Area. Conditions in
More informationRenovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
More informationSTEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope
FOUNDATIONS STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION Build a Better Home Details are critical when constructing a sound building foundation that will withstand water and control dampness.
More informationFOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
More informationHanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
More informationExtra. Technical. November 2014 Issue 16 NHBC STANDARDS GUIDANCE AND GOOD PRACTICE. In this issue:
Technical Extra November 2014 Issue 16 In this issue: NHBC STANDARDS Introducing Chapter 5.4 Waterproofing of basements and other below ground structures page 3 GUIDANCE AND GOOD PRACTICE The basement
More informationMetropolitan Builders Association Masonry & Concrete Standard
Metropolitan Builders Association Masonry & Concrete Standard Background Masonry and concrete work in residential construction often provides the base structure upon which the house is built or as a veneer.
More informationSection 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS
TABLE OF CONTENTS 2.18 CONCRETE AND/OR CORRUGATED STEEL STORM SEWER... 1 2.18.1 GENERAL... 1 2.18.2 MATERIALS... 1 2.18.2.1 Storm Sewer Pipe... 1 2.18.2.2 Cement Mortar... 1 2.18.2.3 Granular Materials...
More informationSTRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
More informationDAMAGE TO FOUNDATIONS FROM EXPANSIVE SOILS
DAMAGE TO FOUNDATIONS FROM EXPANSIVE SOILS J. David Rogers, Robert Olshansky, and Robert B. Rogers Expansive soils in many parts of the United States pose a significant hazard to foundations for light
More informationState of Connecticut Department of Public Health RADON PROGRAM
State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon
More informationWATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
More information-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION
-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION -Unit number- 4420798 -Unit title- CONSTRUCTION TECHNOLOGY 2: SUBSTRUCTURE AND REMEDIAL WORKS -Superclass category-
More informationInterior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
More information90 Brighton Road, Surbiton, Surrey
90 Brighton Road, Surbiton, Surrey Civil and Structural Engineering Basement Feasibility Report Mixed Use Scheme 108802-REP-002 March 2015 Contents 1. Executive Summary... 3 2. Site Description and Constraints...
More informationTECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
More informationWATERPROOFING SikaProof -A TECHNOLOGY
SikaProof -A TECHNOLOGY content What is SikaProof -A? 6 How does it work? 8 Where can it be used? 0 What are the advantages of SikaProof -A? 2 How should it be installed? SikaProof -A system components
More informationEmergency Spillways (Sediment basins)
Emergency Spillways (Sediment basins) DRAINAGE CONTROL TECHNIQUE Low Gradient Velocity Control Short-Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1] [1]
More information