CCTV XPPOS POS/ATM INTERFACE INTEGRATION MANUAL XPPOS. User Guide. Contents. 2006-09 Edition



Similar documents
GV-Data Capture V3 Series User's Manual

POS Integration. Prepared by: Binh Nguyen

You can search the event by POS and you can also add the Time Search condition to narrow the search range. By

Metadata Plugins Access Control, License Plate Recognition and Point of Sale Solutions

INTRODUCTION FEATURES OF THE ICM

VRX Company Inc. Application Note: DacEasy Point of Sale setup for Pole Display

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Follow these steps to prepare the module and evaluation board for testing.

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

T3 Mux M13 Multiplexer

Sollae Systems Co., LTD. ezvsp ver 1.4a

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

CMP-102U. Quick Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide

Configuring the Beckhoff BK9000 Network Parameters

Schneider OS-Loader usage via Ethernet or USB.

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

Knowledge Base POS/C31A Troubleshooting

Configuring the Switch with the CLI-Based Setup Program

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. First Choice For Security Professionals

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

DSA-1000 / PRT-1000 Device Server / Thermal Printer

MS830 / MS833 Barcode Reader v1.0 9-December-2014

Point-Of-Sale (POS) Application

BuTeL Software - Scanner Over Ip - RemoteServer software July

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

Driver Pant 8 and antenna switcher Ant 8. User manual

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

LBNP RS-232/485/422 serial device server. User manual

Connecting the DG-102S VoIP Gateway to your network

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.

Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

NPort. Copyright 2008 Moxa Inc. Released on July 15, 2008

Step-by-Step Tutorial For Using LinkSprite UART- WIFI Module Model LS_UART_WIFI

SCS3205/4805 Quick Start Guide

Voice Over Internet Protocol (VoIP) Configuration

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Application/Connection Examples

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

EZ-View Network Communications Guide

LS-101 LAN to Serial Device server. User s Manual

C24-CAMANL Video Server/Encoder

Introduction: Implementation of the MVI56-MCM module for modbus communications:

Bits per Second Data Bits Parity Stop Bits Flow Control None 1 None

USR-TCP232-T Hard Version: V2.0 Doc Version: V

Table of Contents. Creating a VC1000 Network... 3

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

PLC training panel (Twido version)

Long Range Ethernet Extender

IP Surveillance TroubleShooting Guide Version: 0.9 Release:

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Quick Start Guide. Hybrid DVR DS-9000 Series Hybrid DVR DS-7600 Series Hybrid DVR. NVR DS-9600 Series NVR

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

isco Connecting Routers Back to Back Through the AUX P

How to use Citect (SCADA) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

USB to RS-422/485 Serial Adapter

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

FINS Gateway For OMRON PLCs

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

Signature Center Getting Started Guide

Serial Over IP Ethernet Device Server

Prestige 650R-31/33 Read Me First

CONFIGURATION OF SATO LAN and WiFi INTERFACES

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

1. MOXA NPort Express TCP/IP to RS-232 server

ReadMe File. Installing the Unified Messaging Application for

Bluetooth to Serial Adapter

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

ezvsp User's Manual ( Version 2.1d ) Sollae Systems Co., Ltd.

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

Load Balancing ContentKeeper With RadWare

1 Axis camera configuration IP configuration Setting up date and time Installing an IPS Analytics Application...

Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions

s!nus-elektrotechnikai bt. Industrial IT & Automation

SecureLinx Spider Duo Quick Start Guide

Transcription:

CCTV XPPOS POS/ATM INTERFACE INTEGRATION MANUAL 2006-09 Edition Contents 1. Introduction... 2 1.1 Features... 2 2. Direct POS To Connection... 2 2.1 System Connection... 2 2.2 Connection Diagram... 2 2.3 Program Setup... 2 3. POS To Connection Through... 3 3.1 Overview of... 3 3.1.1 DIP Switch Selection... 3 3.2 System Connection Through... 4 3.2.1 DB9 Input Connection... 3.2.2 DB25 Input Connection... 3.2.3 RS485 Output Connection... 4 4 4 3.2.4 RJ45() Output Connection... 5 3.3 Assigning IP Address to... 3.4 POS Configuration From Program... 3.4.1 Serial Output From... 3.4.2 RJ45 () Output From... 5 6 7 7 4. POS To Connection Through TCP/IP 5. POS Transaction Data Search... 8... 8 XPPOS User Guide

Introduction A POS system may be integrated to system through direct serial connection or using H/W. Through the integration, you can investigate a transaction with transaction data overlaying on a video image, by either live viewing or playing back. 1.1 FEATURES - Viewing transaction text data overlayed on live and playback images - Transaction data stored on database file - Transaction data can be searched by the terms specified with corresponding video image - Supports up to 16 POS systems (using ) - Adjustable text and viewing area size 2. Direct POS To Connection 2.1 System Connection When the physical distance between POS system and is short (less than 10m(32ft)), serial connection (RS232) can be used. 2.2 Connection Diagram Connect cross-wired serial cable (DB9) from POS system to directly. Cross wired Serial (DB9) Less than 10m (32ft) 2.3 Program Setup Run the Program. Go to Control Setup and check on POS Enable and press Setting. Then check on "Serial". Set Module to the name available from the list or "General" if not from POS Setup. And set Serial properties (Baud Rate, etc) corresponding to the currently connected.

3. POS To Connection Through 3.1 Overview of When the distance between and is longer than 10m (32ft) or more than 2 s are connected, the H/W can be utilized Front view: RS232 Female From POS (DB9) Parallel Male From POS (DB25) RS485 To RS232 Female To (DB9) RS232 Male To Printer Parallel Female To Printer (DB25) Rear View: RJ-45 Connection DIP Switch For Serial or Parallel Input and Baud Rate See Next Section 3.1.1 DIP Switch Selection Input Type Selection (depending on the output type from POS) DC5V Power Adapter Connection Serial Input: Parallel Input: Baud Rate Selection: (depending on the Baud Rate which POS has) Baud Rate 1 2 3 4 2400bps OFF OFF OFF OFF 4800bps OFF OFF OFF ON 9600bps OFF OFF ON OFF 19200bps OFF OFF ON ON 38400bps OFF ON OFF OFF 57600bps OFF ON OFF ON

3.2 System Connection Through 3.2.1 DB9 Input Connection Physical distance between POS and should be less than 10m (32ft). Serial (DB9) Serial (DB9) COM 1 Serial (DB9) Serial (DB9) COM 2 3.2.2 DB25 Input Connection Physical distance between POS and should be less than 10m (32ft). Parallel (DB25) Serial (DB9) COM 1 Parallel (DB25) Serial (DB9) COM 2 3.2.3 RS485 Output Connection For distances greater than 10m (32ft). RS232 Input RS485 Output RS232 Or USB RS485-to-RS232 or to-usb Convertor

3.2.4 RJ45() Output Connection For distances greater than 10m (32ft) or up to 16 s connection over TCP/IP network Serial or Parallel Serial or Parallel NETWORK HUB Serial or Parallel Up to 16 POS NOTE: IP address must be assigned the. Please refer to the next section. 3.3 Assigning IP Address to When RJ45() output method is used to, IP address must be assigned over TCP/IP network. Plug in the to network and run POSConverter.exe from CD-Rom provided or from C:\DVSS4\POSConfig and IP configuration tool runs as shown below. Ì

Search Run Search and MAC Addresses of all POS converters connected to will be listed on Module List. POS Network Setting Enter internal IP address (e.g 192.168.100.1), Subnet, and Gateway. Set Port to default 5000. Network Setting Enter IP address of. Set Port to default 5000. POS Serial Setting Set Baud to 57600, DataBit to 8, Parity and Flow to None. Delimiter: Time, Size, Character Enter 0 in Time and Size and type 0A (hexadecimal) in Character. Operation mode: TCP server, TCP client Select TCP client and Startup to connect to. Setting After configuration is done, press Setting to apply the changes. 3.4 POS Configuration From Program Run program. Go to Control Setup and check on POS Enable and press Setting.

3.4.1 Serial Output From Communication Type Select Serial POS Setup - POS Device / Mapping Camera : POS1 connects to Cam1, POS2 to Cam2etc - Module : set to the name available from the list or "General" if not - Duration : text display time on live video image Display Setting - Show : check on to view text on live video image - Font Setting : set font color, size and weight of the text displayed - Text Area : set text viewing area in live camera view A Term Of Saving DB Set the period to keep transaction data in DB. Default 7 days. Serial - Set POS Port to the current COM port connecting to. - Set Baud Rate, Data Bit, Parity Bit and Stop Bit to the same value the POS has 3.4.2 RJ45 () Output From Communication Type Select TCP/IP POS Setup - POS Device / Mapping Camera : POS1 connects to Cam1, POS2 to Cam2. - Module : set to the name available from the list or "General" if not - Duration : text display time on live video image Display Setting - Show : check on to view text on live video image - Font Setting : set font color, size and weight of the text displayed - Text Area : set text viewing area in live camera view A Term Of Saving DB Set the period to keep transaction data in DB. Default 7 days. TCP/IP Enter the IP address of (refer to 3.3 Assigning IP Address to )

4. POS To Connection Through TCP/IP If the has the capability of sending transaction data through TCP/IP to the specified IP address of (normally PC-based ), TCP/IP connection method can be used without. NETWORK HUB Up to 16 POS As this integration job may require more customizing depending on the capability of POS, please contact your local distributor to get more technical information. 5. POS Transaction Data Search Run POS Search from Search Mode of Program to search from transaction data DB. Terms for Search Video Image View Search Result Playback Control