Installation Guide - Alarm Module T941AM8



Similar documents
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Combi B Alarm box. Mounting instructions

Modular I/O System Analog and Digital Interface Modules

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

T0118 T2118 T3118. Instruction Manual

3M Wrist Strap and Footwear Tester 740. User s Guide

IO-DIM6 6-Channel, Digital to Analogue Converters

PROXIMITY CARD READERS C-10, C-20, C60, C70

Assembly and User Guide

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

3 740 Wrist strap + shoe tester

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Digital Keypad Use s Manual

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Kit Watt Audio Amplifier

IO-RM3 3-Stage Relay Module

SECURITY SYSTEM ADP-CAN

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

SYSTEM DESCRIPTION Termination Boards

SYSTEM 4C. C R H Electronics Design

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

BUILDING INSTRUCTIONS

Total solder points: 167 Difficulty level: beginner advanced DMX CONTROLLED RELAY K8072 ILLUSTRATED ASSEMBLY MANUAL

PCS0100en Persy Control Services B.V. Netherlands

EMBEDDED ACCESS CONTROL Hardware Installation Guide

7-SEGMENT DIGITAL CLOCK

HMI display Installation Guide

8 Channel Status Input Panel model SIP-8

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

COMPALARM AP GENERAL MAIN FEATURES

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

BMD16N-SD. version 1.2

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

SYSTEM 45. C R H Electronics Design

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Contents. Document information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

ECEN 1400, Introduction to Analog and Digital Electronics

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

is then retained absolutely without interruption.

OPT SERIAL TO FIBER OPTIC CONVERTER

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

WD-AMX Water Detection Controllers

UniPi technical documentation REV 1.1

TC-9102 Series Surface Mount Temperature Controllers

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Installation Manual for D0700 ISDN Analogue Converter

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Manual for Fire Suppression & Methane Detection System

Automatic Telephone Dialer TD-101(W)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

TrueAlarm Fire Alarm Systems

Install the DeviceNet Module using the following procedure:

AUTODIALLER / QUICKDIALLER - SA132

Color Mark Sensor with Red or Green LED E3S-VS

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

ZC-24DO CANopen I/O Module: 24 Digital Outputs

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

INSTALLATION INSTRUCTIONS

USB to RS-422/485 Serial Adapter

Praesideo PRS-CSM / PRS-CSRM / PRS-CSKPM Digital Public Address and Emergency Sound System

Advantium 2 Plus Alarm

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

K8025 VIDEO PATTERN GENERATOR. Check the picture quality of your monitor or TV, ideal for adjustment or troubleshooting.

NetworX Series. NX-216E Zone Expander Module Installation and Startup

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.

NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Speed Control Relays SX2

User manual Compact Web PLC WP240 series IEC-line

Model SETR-50 and SETR-51 Trim Tab Control

Installation instructions for Series NRX INCOM communications adapter module

Shunt lock function 3066

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Model 201 Wiegand Touchpad Reader Installation Guide

OZW30. Central Unit SYNERGYR

Single Channel Loop Detector

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Contractors Guide Central Inverter System Installation

GLOLAB Universal Telephone Hold

General Purpose Relays Accessories. Accessories Miniature Relay PT

Troubleshooting and Diagnostics

ACS-30-EU-EMDR-10-MOD

step 1 Unpack the lunchbox And check whether you have got all the components~ If you have questions please contact us at: info@unitunlikely.

SECTION 3A (Rev.F) SECTION CONTENTS. Download from Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...

Transcription:

Alarm Module T9AM Installation Guide - Alarm Module T9AM T9AM has physical inputs for connection to external alarm devices. Inputs are galvanically isolated, have transient protection, and can be programmed for making or breaking contacts. There are an additional 5 logical inputs that can only be activated by programmed parameters. A FLASH PROM in T9AM enables remote programming of the program and parameters. T9AM is used in telecourier 900, teleprotect 900, and CTS 900. T9AM is not intended for connection to public telephone networks.. General As a complement to this installation guide, see also the System Installation document for the respective system : telecourier 900, doc. no. TD 907GB, teleprotect 900, doc. no. TD 907GB, or CTS 900, doc. no. TD 90795GB. 5,5,5 Dimensions (H x W x D) 75 x 0 x 0 mm 9 9 75 Supply voltage:,5 Vdc ± 0% Current 50 ma max consumption: + 00 ma max for all inputs. For selection of input connection see point 9. Delivery includes: T9AM Modular bus cabling If T9AM is to be used in a system with speech, speech module T9SM must be mounted on the PC board. Installation Guide TD 90GB for T9SM should be included in the delivery Tools etc., required: Screw driver Screws for installation Soldering iron 5 0 Note: To facilitate service after the unit is installed, we recommend a free space of about 50 mm above and 50 mm below the unit.. Installation The alarm module should be placed in a dry environment with a temperature range of 0 to +0ºC. The alarm module can be connected together with other units in the 900 system, either via modular system bus cabling or via twisted-pairs (point ). To replace the PC board, see point. The second drawing at left shows dimensions for installing the alarm module. Use a screwdriver or similar to release the cover by applying a light pressure to the two snap catches () and remove the cover (). 995 0

Alarm Module T9AM. Screw Connectors etc. for Installation SWO SW0 LEDO LEDO J0, J0: Modular bus cabling for connection of A, B, D, and SP bus. J0: Supply voltage and connection of A or B bus. J0: System fault. S0 ICO J05: External acknowledgement input. S05 ICO J0: Connector for speech module 9SM. J07: Alarm inputs. S S0 J0: Alarm inputs 5. IC0 J09: Supply voltage for alarm inputs and external acknowledgement input. For galvanic isolation an external power supply is required (always used in CTS 900). J0 J0 LED0 RE0 LED0 S S0 J05 S0, S0: Jumpers for selection of A or B bus. S0: Not used. S0, S05, Jumper points that must be soldered together S0: to enable use of software program S90AM. See point. S0-S: Jumpers for selecting type of alarm inputs, i.e. make/ break or ring signal, or for external power supply (e.g. nurse call). SW0: Address selector switch. J0 S0 S0 J0 J0 SW0: Switch, must always be set to OFF. SW0: is used for test SW0: is used to generate test pagings. J0 J09 J07 LED0 Function indicator for green, red, or orange indication LED0: Sum alarm indicator PC board LED0 Indicators for alarm inputs LED0: IC0: Flash PROM, program memory. Installation Together With Other 900 Units. Remove upper and lower covers. The lower rectangular pieces are used to fasten units to each other ().. Fasten the unit with three screws, see the illustration on page. 995 0

Alarm Module T9AM 5. Addressing Select the proper address by setting address selector switch SW0 (see the document System Installation, under "Addressing"). The address must not be 00 nor the same as any other 900 unit address.. Use pliers to break off a suitable section.. Run the wiring out through the partition. Wiring can be run three ways from the alarm module: Remove the rectangular pieces and run the cabling out through the side (). OFF ON SW0 R0 R0 S0 S0 Break off sections at short side of case and run the cabling downwards (). Run the cabling through the round holes at the bottom of the case () Secure the wiring with cable straps.. Selection of A or B Bus A bus is normally used (always used in CTS 900). To use B bus: remove the 0 ohm resistors R0, R0 from the PC board and solder together jumper points S0 and S0. (See drawing above.) 7. Wiring Runs The plastic partition (shaded in the drawing) is scored to facilitate breaking at convenient intervals.. Connecting Supply Voltage and Buses. Supply voltage is connected to screw and of screw connector J0. (See the document System Installation, under Supply Voltage ).. Connect modular bus cabling to J0 and J0 ( in drawing at below left), and/ or A or B bus to J0 screw 5 and (dwg below and in drawing at left). Use only A bus in CTS 900! NOTE: The data lines are polarised. Use only twisted-pairs for two-wire connections! 5 Supply voltage in Supply voltage out A or B bus J0 +V GND 5 BUS BUS 995 0

Alarm Module T9AM 9a. Connecting Alarm Inputs for Voltage-Free Make/Break left jumper right jumper. Connect twisted-pairs to alarm inputs that are to be used: J07 for inputs and J0 for 5. S S. Connect supply voltage to J09. This can be taken from J0- and -. However, for galvanic isolation an external power supply must be connected to J09 (always used in CTS 900). S S0 S09 S0 S07 Alarm input Alarm input Alarm input Alarm input Alarm input 5 Alarm input Alarm input 7 Alarm input J07 J0 5 7 5 7 ALARM INPUT ALARM INPUT ALARM INPUT ALARM INPUT ALARM INPUT 5 ALARM INPUT ALARM INPUT 7 ALARM INPUT S0 Jumpers S0-S: S0-S with jumpers inserted for voltage-free make/break with common power supply. S07 with jumper inserted for voltage-free make/ break with individual external power supply. S0 with jumpers removed for ring signals. 9b. Connecting Alarm Inputs for Ring Signals. Connect twisted-pairs to alarm inputs that are to be used: J07 for inputs and J0 for 5. Supply voltage J09 EXTERNAL VDC + EXTERNAL VDC. Check that jumpers S0 S are not inserted for the corresponding alarm inputs ( ) that are used (see dwg. above). For an alarm input used for ring signals both left and right jumpers must be removed.. Check that jumpers S0 S are inserted for the corresponding alarm inputs ( ) that are used (see dwg below). For voltage-free make/break of an alarm input with common external power supply both left and right jumper must be inserted (i.e. in position - and -). For voltage-free make/break of an alarm input with individual external power supply (e.g. nurse call) the corresponding jumper must be in position -. Alarm detection requires a current of at least 0, ma. Max voltage on make/break alarm inputs is V. 0. Acknowledgement Input Connection. Connect twisted-pair to ACKN, screw and on connector J05, (unpolarized).. Connect supply voltage to J09. (See dwg at left above). This can be taken from J0- and -. However, for galvanic isolation an external power supply must be connected to J09. Acknowledge input J05 ACKN. TEST ACKN. 995 0

Alarm Module T9AM. System Error Indication (not used in CTS 900) System fault relay RE0 has two parallel contacts that can be connected for make or break function. System fault System fault J0 COM NO SYSTEM ERROR NC COM 5 NO SYSTEM ERROR NC For system fault loop connect the twisted-pair to J0: screw and for make contact screw and for break contact For system fault loop connect the twisted-pair to J0: screw and 5 for make contact screw and for break contact. Installation Test Procedure. Check that switch SW0 is set to OFF.. Energize the 900 system. Function indicator LED0 on the alarm module should light red for about second and then go over to a flashing orange. If it continues to indicate with a steady red check that supply voltage is,5 Vdc ± 0%. Flashing red indicates a program fault. Function indicator. Jumpering for Software Program S90AM To enable use of software program S90AM remove 0 ohm resistors R0, R05 and R (not R), and solder together jumper points S0, S05, and S. In this case, an EPROM can be used as program memory IC0 instead of the FLASH memory. Software program S90AM also affects the function of LED0 (orange indication is replaced by green).. If the alarm module is connected to a central, the indicator should show a steady green indication within 90 seconds. If the indicator continues to blink orange, check: polarity connections on alarm module Alarm module is properly addressed S0 R0 S05 R05 IC05 IC0 If everything seems to be OK but the function indicator still blinks, the fault is probably located outside the alarm module: Check the other 900 units according to the document System Installation, or contact your dealer. IC5 IC0 IC0 R IC S R. Replace the cover. When all other units are installed, perform the system test described in the System Installation document for the respective system: telecourier 900, doc. no. TD 907GB, teleprotect 900, doc. no. TD 907GB, or CTS 900, doc. no. TD 90795GB. 995 0 5

Alarm Module T9AM. PC Board Replacement. Deenergize the unit.. Remove the cover.. Lift off the screw connectors from the PC board.. Press the four holding clips to release the PC board (). The heat sink is mounted on the PC board and is replaced simultaneously. 5. Install the new PC board in the case and make sure the board clicks into position.. Set all switches and jumpers as they were on the original circuit board and replace the screw connectors. 7. Check installation according to point Installation Test Procedure. 995 0