F irestone Polyiso I nsulation



Similar documents
Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

COMMERCIAL BUILDING APPLICATIONS

CHAPTER 7: Building Systems ROOFING SYSTEMS

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE

Proven roofing SyStemS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

PIMA Technical Bulletin #115. The High R Roof: Guidelines for Energy-Efficient Roofing and Re-Roofing. What is a High R Roof?

Polyiso Insulation. Tapered Polyiso Insulation

Polyiso Insulation. Insulation Pieces Square Feet Square Feet Square Feet Thickness Per Bundle Per Bundle Per Bundle Per Truckload

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

also in this issue Automatic Doors for the People Calculating Roof Insulation R-values Waterproofing and Concrete Balconies

Polyiso Insulation. Tapered Polyiso Insulation

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

For every building that matters

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE

Roof Insulation Building. Energy. Environment friendly e-library

Low-slope reroofing guidelines

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Building Owners Guide to a Duro-Last System!

Roofing Systems. New Applications / Re-Roofing / Maintenance

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Tapered Polyiso Roof Insulation & Gemini Products

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

TARRANT COUNTY DETAIL STANDARDS

Continuous Insulation Using Polyiso Wall Sheathing

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

metal Duil~ing manufacturers Association

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fiberglas, Exterior Wall Thermal Insulation

Firestone Warranty Program

FOAMULAR XPS Roof Insulation FOR COMMERCIAL BUILDINGS

THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

Peel & Seal Self-Stick Roofing Solutions

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Achieving Maximum Roof Performance at the Lowest Installed Cost With Invinsa Roof Board

Firestone SBS Modified Bitumen Roofing System Design and Application Guide

Specifying SPF Roofing Systems

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Underwriters Laboratories Testing Information

Prices Effective April 1, 2016

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association

EPDM. Roofing systems

CARLISLE S. c a r l i s l e - s y n t e c. c o m

FOAMULAR Tapered Roofi ng Products Extruded Polystyrene (XPS) Rigid Foam Insulation

ANSI/SPRI WD-1 Wind Design Standard Practice for Roofing Assemblies. Table of Contents. 1.0 Introduction Methodology...2

EXPANDED POLYSTYRENE FOR. ResidentialBuilding Applications

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

Meeting the Fire Code with Continuous Foam Plastic Insulation

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

SCIENCE. SERVICE. SOLUTIONS. ROOF GARDEN. CCW Green Roof Systems By Columbia Green Technologies

CHICAGO ROOFING CONTRACTORS ASSOCIATION

CRS Sales & Marketing

ROXUL TOPROCK DD & MONOBOARD. Roofing Insulation for Commercial Construction. ROXUL TOPROCK DD and MONOBOARD

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

What makes DECRA Roofing Systems unique?

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Laboratory Report P Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C

Jm Tpo systems Single Ply Roofing

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

MASTERFORMAT SPECIFICATION

Georgia State University. Urban Life Building Roof Replacement

Roof Restoration System. For building owners, property management firms and facility managers. seamless possibilities

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

Proper roof slope and drainage are important to prevent excessive water accumulation

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, RBA Project No

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

Gridstone Gypsum Ceiling Panels

Roofing Retrofits: Focus on Sustainability

SECTION PLAYGROUND SURFACING TILES

How To Compare Roofing Material

PVC ROOFING SYSTEMS BUILDING SOLUTIONS A SINGLE SOURCE FOR SINGLE-PLY ROOFING

Table of Contents. To access data on JM Roofing Systems, visit our Web site at

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

JM s Commitment to Meeting Your Single Ply Roofing Needs. JM PVC with DuPont Elvaloy KEE (Ketone Ethylene Ester) Single Ply Systems

Firestone RubberGard The EPDM reference

Landscaping products and amenities /

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

Get Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money

How To Replace A Roofing System In Florida

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012

3 Single-Coated Foam Tapes

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Materials and Colors

UL Online Certifications Directory

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In


Transcription:

F irestone Polyiso I nsulation EnERgy EffiC i E n C y. P OWERf U l P ERf ORMAn CE. SignifiCAnt S A vings. FIRESTONE ISO 95+ GL FLAT INSUL ATION FIRESTONE ISO 95+ GL TAPERED INSUL ATION RESISTA POLISO INSUL ATION BOARD FIRESTONE I SOGARD HD COVER BOARD FIRESTONE HAILGARD COMPOSITE BOARD

THE P R O D UCT OF CHOICE FOR LONG-TERM P ERFORMANCE Firestone Polyiso Insulation WHAT IS POLISO INSULATION? Polyisocyanurate (polyiso) is a closed-cell, rigid foam insulation board made with recycled content that is widely used in commercial roofing. WH POLISO INSULATION? Polyiso insulation is the best choice as a cost-effective, energy efficient and environmentally responsible insulation product. A true environmental winner, polyiso is a good choice for Leadership in Energy and Environmental Design (LEED ) credits. POLISO S UNIQUE B E N E FITS INCL U DE Highest R-value per inch Outstanding installed cost advantages Proven fire resistance Responsible impact on the environment through energy savings Preferred insurance ratings Superior strength Moisture resistance Building code approvals Better for the Environment Firestone polyiso insulation products consist of a closed-cell polyiso foam core that is HCFC-free and has no Ozone Depletion Potential (Zero-ODP). All Firestone polyiso products comply with the United States Environmental Protection Agency and the Montreal Protocol requirements. Energy and Atmosphere Credits EA Pre-requisite 2: Minimum Energy Performance EA Credit 1: Optimize Energy Performance (1 19 points) LEED BENEFITS Material & Resources Credits MR Credit 2: Construction Waste Management (1 2 points) MR Credit 3: Material Re-Use (1 2 points) MR Credit 4: Recycled Content (1 2 points) MR Credit 5: Regional Material (1 2 points) Firestone Building Products belongs to the Polyisocyanurate Insulation Manufacturers Association and has certified LTTR-value products verified by the Quality Mark cm Program.

Polyiso for Lower Heating Costs & Tax Incentives The Energy Policy Act of 2005 provides tax deductions for owners of commercial buildings that exceed ASHRAE 90.1. Because polyiso insulation has the greatest energy efficiency performance of any building insulation on the market, it can help building owners meet and exceed the requirements to earn these tax benefits. Why Firestone Polyiso Insulation? When installing a new roofing system, insulation can account for more than half of your investment. That s why using insulation from a manufacturer you trust is so important. Installing Firestone polyiso insulation as a part of a Firestone Total Roofing System provides a single source of quality, materials and warranty responsibility. Firestone Building Products is the only North American manufacturer to produce a complete line of roofing systems including insulation, EPDM, TPO, Modified Bitumen (APP and SBS), Built-up, and Metal roofing, plus standard and custom accessories. With Firestone, you get one source with everything needed for any roof design. The R-value of our Insulation Can Optimize our Energy Savings in Any Zone Commercial Roof Insulation Recommendations Zones 1 3 PIMA Recommended R-value R-20 Zones 4 6 PIMA Recommended R-value R-25 Zones 7 and 8 PIMA Recommended R-value R-30 All of Alaska in Zone 7 except for the following Boroughs in Zone 8: Bethel, Dellingham, Fairbanks N. Star Northwest Arctic, Southeast Fairbanks Wade Hampton, ukon-koyukuk Zone 1 Includes: Hawaii, Guam Puerto Rico, Virgin Islands

F i r e s t o n e I S O 9 5 + G L I n s u l a t i o n BECAUSE IT S HIGHL ENERG EFFICIENT WITH THE HIGHEST R-VALUE RATINGS PER INCH, THE USE OF ISO 95+ GL IN A FIRESTONE ROOFING SSTEM PROVIDES A COST EFFECTIVE SOLUTION FOR TODA S ROOF DESIGN CHALLENGES AND IS PREFERRED FOR AN AND EVER ROOFING SSTEM. THE HIGHEST THERMAL RATINGS. THE HIGHEST VERSATILIT. This versatile insulation is especially suited for FM approved and UL classified direct-to-deck applications/assemblies without an additional thermal barrier in most installations. ISO 95+ GL polyiso insulation boards have a glass reinforced facer on both sides of the foam core and can be attached with hot asphalt or low rise foam adhesive to various substrates, or mechanically fastened with Firestone fasteners and plates. PHSICAL PROPERTIES PROPERT TEST METHOD TPICAL VALUE Density ASTM D 1622 2 pcf Compressive Strength* ASTM D 1621 20 psi Dimensional Stability ASTM D 2126 2% max. Moisture Vapor Transmission ASTM E 96 <1.0 perm Water Absorption ASTM C 209 <1.0% volume Service Temperature 100 F to +250 F * For requirements greater than 20 PSI, phone Firestone s Estimating Services Department at 800-428-4442.

THERMAL PROPERTIES NOMINAL NOMINAL LTTR* MAIMUM MAIMUM THICKNESS THICKNESS FLUTE SPAN FLUTE SPAN IN MM IN MM 1.00 25.4 6.0 2.625 66.70 1.25 31.7 7.5 3.675 93.35 1.50 38.1 9.0 4.375 111.10 1.75 44.5 10.5 4.375 111.10 2.00 50.8 12.1 4.375 111.10 2.30 58.4 14.0 4.375 111.10 2.50 63.5 15.3 4.375 111.10 2.80 71.1 17.2 4.375 111.10 3.00 76.2 18.5 4.375 111.10 3.25 82.6 20.1 4.375 111.10 3.50 88.9 21.7 4.375 111.10 3.75 95.3 23.4 4.375 111.10 4.00 101.6 25.0 4.500 114.30 * Note: Long Term Thermal Resistance (LTTR) values have been determined in accordance with CAN/ULC S770. Product Availability Board sizes of 4' x 4' and 4' x 8' and in thicknesses of 1.0 to 4.0. Other sizes and thicknesses may be special ordered. Minimum order quantities may apply.

" " " " F i r e s t o n e I S O 9 5 + G L T a p e r e d I n s u l a t i o n WHEN A SUBSTRATE SLOPE WILL NOT PERMIT EFFICIENT DRAINAGE, FIRESTONE TAPERED ISO 95+ GL POLISO INSULATION PROVIDES AN EFFECTIVE AND ECONOMICAL SOLUTION. PROPERL INSTALLED TAPERED ISO 95+ GL CAN ETEND THE LIFE OF THE ROOF ASSEMBL B ELIMINATING PROBLEMS ASSOCIATED WITH PONDED WATER. TAPERED INSULATION EPERTISE AND PRODUCT SUPPORT Firestone is committed to providing accurate and timely tapered take-offs that encompass all critical elements affecting proper drainage. The Firestone Tapered Network, a free service, uses the latest technology to offer architects, consultants, general contractors, distributors and roofing contractors a complete and accurate tapered insulation system for any project. Working closely with the customer, Firestone s Tapered Network team will generate a proprietary CAD drawing that clearly identifies the proper placement of tapered insulation on the roof, including the location of crickets, drains and other elements critical to proper drainage. 2 * 1 * 1" FILL 2.5" 2.25" 2" 1B* 1A * 1.75" 1.5" 1.25" 1" 2 * 1 * TPICAL SECTION 1/16"/FT. SLOPE N.T.S. 1B * 1A * 0.75" 0.5" C 2" FIL L 4.5" B 4" A 2" FIL L 3.5" AA C TPICAL SECTION 1/8"/FT. SLOPE N.T.S. 3" 2.5" B 2" A 1.5" AA 1" KK* 3 FIL L JJ* 5" 4.25" MM* TPICAL SECTION 3/16"/FT. SLOPE* N.T.S. 0.5" 3.5" LL* 2.75" KK* JJ* 2" 1.25" 0.5" I * 7" H 3 FIL L 3 FI L TPICAL SECTION 1/4"/FT. SLOPE N.T.S. 6" G 5" I * 4" H 3" G Z * 2" 3 F I L 3 " F I L 1" 6.5 " 5.5" Z * TPICAL SECTION 1/4"/FT. SLOPE N.T.S. 4.5" 3.5" 2.5" 1.5" 0.5" 2 " F I L Q Q 4.5" TPICAL SECTION 1/2"/FT. SLOPE N.T.S. 2.5" 0.5" Contact your local Firestone Sales Representative for additional information.

TAPERED INSULATION PLAN +6 +6 +4 +4 +2 +2 R R R R R R R R +2 +2 +4 +4 These CAD capabilities +6 +6 +8 +8 +6 +6 +6 +6 +4 +4 R +2 +2 +2 +4 +4 +2 +4 +4 +2 +2 R R R R +4 +4 +4 +2 +4 R enable the Estimating Services Department to generate customized drawings tailored to the unique requirements of the R R installation, minimizing the +2 labor and material costs of the finished installation. Contact Firestone s Estimating Services Department for a project quotation or layout guidance. For site assistance or contractor support, contact Firestone s Tapered Project Management Team. Call: 1-800-428-4442 E-mail: estimatingservicesdept@firestonebp.com. Product Availability Board sizes of both 4' x 4' and 4' x 8' (special order), at standard slopes of 1 16, 1 8, 1 4 and 1 2 Boards with slopes of 3 16 and 3 8 may be special-ordered. Board thickness ranges from 0.5 to 4.0 maximum in one layer.

R e s i s t a Pol y i s o I n s u l a t i o n B o a r d WHEN CONSIDERING INSULATION, ORGANIC FACED MATERIAL IS A POPULAR CHOICE. BUT FIRESTONE HAS INNOVATED THE NEW RESISTA POLISO INSULATION BOARD AN ECONOMICAL NEW CHOICE THAT PROVIDES COMPARABLE OR BETTER FIRE, WIND AND ENVIRONMENTAL PROTECTION. THE BEST POLISO INSULATION BOARD JUST GOT BETTER. Firestone's Resista is rewriting the specs on what you think you know about polyisocyanurate insulation. Resista is a smart choice to add an enhanced degree of resistance to any roofing system, standing out in three critical areas: Thermal Resistance Fire Resistance Mold Resistance Resista can also help contribute to overall LEED certification due to its thermal efficiency, recycled content and zero ozone depletion. FIRE RESISTANCE Resista is the only 1 polyisocyanruate insulation board with a UL Class A rating for fire resistance when used over combustible decks and is compatible with single-ply and modified bitumen roofing systems. Competitors may require up to 3.1 of insulation to achieve comparable ratings. UL ROOF ASSEMBLIES AND FIRE RATINGS UL ROOF DECK INSULATION MEMBRANE RATING SLOPE TPE Class A Max. ½ :12 Combustible Min. 1 Resista UltraPly TPO Mechanically Attached or Fully Adhered Class A Max. 1 :12 Non-Combustible Min. 1 Resista UltraPly TPO Mechanically Attached or Fully Adhered Class B Max 2 :12 Combustible Min. 1 Resista UltraPly TPO Mechanically Attached or Fully Adhered Class A Max ½ :12 Non-Combustible Min. 1 Resista FR EPDM, MA, EcoWhite & LS-FR Fully Adhered or Mechanically Attached Class A Max. 2½ :12 Non-Combustible Min. 1 Resista Max FR Fully Adhered or Mechanically Attached Class A Max ½ :12 Combustible Min. 1 Resista Standard EPDM FR EPDM, MA, EcoWhite & LS-FR Fully Adhered or Mechanically Attached Class A Max. ¼ :12 Non-Combustible Min. 1 Resista SBS or APP Torch or Cold Adhesively Applied Class A Unlimited Combustible Min. 1 Resista UNA-CLAD Warranted metal roofing systems * This chart is a brief synopsis of approvals utilizing Firestone Resista insulation board. Please refer to the Technical Database at www.firestonebpco.com for specific requirements and additional approvals.

MOLD RESISTANCE Resista meets ASTM D3273 standards for mold resistance. It is double coated on both sides with a unique non-organic facer material, providing it with exceptional mold inhibiting properties. BENEFITS Environmentally friendly (contains no hydrochlorofluorocarbons) Mold-resistant per ASTM D3273 Recognized by the GREENGUARD Environmental Institute as highly resistant to mold growth based on independent testing using GREENGUARD test method GGTM.P040 for microbial resistance. Offers more roofing system choices Provides valuable energy savings Helps sustain the environment Enhanced FM codes utilizing reduced fastening with Resista Polyiso and ISOGARD HD Board LEED credits for energy optimizations/material resources UL Class A over combustible decks May reduce installation time and labor costs Easy manipulation and placement Product Availability Flat Board sizes of 4' x 4'and 4' x 8' Tapered Board sizes of 4' x 4' and 4' x 8' Slopes ranging 1 16 per foot (.5%) to 1 2 per foot (4%)

F i r e s t o n e I S O G A R D H D C o v e r B o a r d Added protection for any roof. A HIGH-DENSIT COVER BOARD, ISOGARD HD COVER BOARD COMBINES IMPACT RESISTANCE, MOLD RESISTANCE, ENERG SAVINGS AND EASE OF INSTALLATION IN A SINGLE, DURABLE PRODUCT. AND BECAUSE IT S LIGHTWEIGHT AND EAS TO CUT AND INSTALL, ISOGARD HD COVER BOARD CAN OFFER SAVINGS FROM REDUCED TRANSPORTATION COSTS, LABOR AND MATERIAL DURING APPLICATION. PLUS, IT PROVIDES THE HIGHEST THERMAL PERFORMANCE OF AN ½" INSULATION COVER BOARD PRODUCT ON THE MARKET. A WINNER IN WIND UPLIFT PERFORMANCE Excellent wind uplift performance means Firestone ISOGARD HD requires fewer fasteners than other comparable products. In terms of energy efficiency, easy handling and other important advantages, Firestone ISOGARD HD is the clear winner. REDUCE COSTS B ACHIEVING DESIRED R-VALUE WITH ISOGARD HD Suppose a design specification for a new warehouse calls for an R-value of 20 with a cover board. The following example demonstrates why ISOGARD HD is a better value: SSTEM 1 SSTEM 2 2 layers of 1.5 ISO = 18.0 R-value vs. 2 layers of 1.75 ISO = 21.0 R-value ½ HD Board = 2.5 R-Value vs. 1 4 gypsum =.28 Total R-value = 20.5 vs. Total R-value = 21.28 Utilizing the Firestone HD Cover Board helps reduce the thickness of the initial layers of insulation and thereby reduces the costs of the project.

Fasteners per 4' x 8' Sheet 12 1 2 Firestone ISOGARD HD Fastener Density for 1-90 Rating Fully Adhered Systems 12 1 4 Glass Mat Faced Gypsum Primed 15 1 4 Glass Mat Faced Gypsum 16 1 4 Glass Faced Polyisocyanurate 16 1 4 Cellulosic Wood Fiber Resistance (R) hr sqft F/BTU 2.5 1 2 Firestone ISOGARD HD R-Value per Thickness 1.32 1 2 Cellulosic Wood Fiber 1.0 1 4 Glass Faced PolyIso.28 1 4 Glass Mat Faced Gypsum Product Availability Board sizes of 4' x 4' and 4' x 8'. Weight of 12 lbs. per 1 16 4' x 8' sheets. Wind uplift performance I-90 (at 12 fasteners per 4' x 8' board).

F i r e s t o n e H a i l G a r d C o m p o s i t e B o a r d Added protection for any roof. HAILGARD IS AN INSULATION PANEL CONSISTING OF A POLISO FOAM CORE LAMINATED TO A 7/16 ORIENTED STRAND BOARD (OSB) ON ONE SIDE, AND A BLACK GLASS REINFORCED MAT FACER ON THE OTHER SIDE. THIS NAILABLE OSB SURFACE MAKES HAILGARD SUITABLE FOR USE WITH EPDM, TPO, MODIFIED BITUMEN AND METAL ROOFING SSTEMS. HailGard provides excellent thermal performance and is a suitable substrate over structural decks on low and steep roofing systems. Plus, it can be used as a component of a Firestone Platinum system to achieve a 30-year Platinum-PHW Warranty, protecting against accidental puncture, hail up to two inches in diameter and 100 mph winds.

THERMAL PROPERTIES NOMINAL NOMINAL LTTR* WEIGHT THICKNESS THICKNESS IN MM lb/sq ft 1.5 12.7 6.6 1.60 2.0 50.8 9.6 1.69 2.5 63.5 12.7 1.77 3.0 76.2 15.9 1.85 3.5 88.9 19.1 1.93 4.0 101.6 22.3 2.02 * Long-term thermal resistance (LTTR) values have been determined in accordance with CAN/ULC S770.

PLANT LOCATIONS Firestone insulations are manufactured in eight plants located throughout North America: Jacksonville, FL Florence, K Bristol, CT Corsicana, T Salt Lake City, UT oungwood, PA DeForest, WI PA C KAGING & SAF E T Firestone ISO 95+ GL Flat and Tapered insulation is wrapped during product packaging with Firestone TuffWrap. Wrapping the product makes it easier and safer to work with for those who ship the product and for those who install it. It s another example of our commitment to safety before, during and after our products are installed. CAUTIONS & LIM ITATIONS Firestone insulation products are non-structural, non-load-bearing materials. The finished roof assembly should be protected from excessive roof traffic with proper walkway materials. Firestone s insulation products have been designed and engineered for use in commercial and industrial roofing applications. The manufacturer makes no claim as to their performance or suitability in residential applications. WARNING Polyiso foam will burn if exposed to a flame of sufficient heat and intensity. Firestone ISO 95+ GL polyiso insulation and Tapered ISO 95+ insulation should not be used in exposed or inadequately protected applications. Polyiso insulation must be installed in accordance with the manufacturer s recommendations. LIM ITED WARRANT Firestone warrants its insulation products sold to customers to be free of manufacturing defects and to meet Firestone s physical specifications. Under this limited warranty, any product that is proven to be defective when applied in accordance with Firestone s written instructions and in applications recommended by Firestone as suitable for this product would be replaced with like product (material only) at no charge. This is the buyer s sole and exclusive remedy. All claims concerning product defects must be made in writing within twelve (12) months of shipment. The absence of such claims in writing during this period will constitute a waiver of all claims with respect to such product. This limited warranty shall be IN LIEU OF any other warranty, express or implied, and including but not limited to any implied warranty of MERCHANTABILIT or fitness for a particular purpose. Firestone shall not be liable for any consequential or incidental damages.

THE F I RESTONE DIFFERENCE One Source. Many Choices. SERvICE, STATE-OF-THE-ART PRODUCTS, EPERTISE THESE ARE JUST A FEW REASONS WH CONTRACTORS, BUILDING OWNERS, ARCHITECTS AND SPECIFIERS HAVE TRUSTED FIRESTONE BUILDING PRODUCTS FOR THEIR ROOFING NEEDS. SINCE THE FIRST FIRESTONE BUILDING PRODUCTS WERE INSTALLED IN 1980, FIRESTONE ROOFING SSTEMS HAVE CONSISTENTL DELIVERED THE TWO CRITICAL NEEDS ALL BUILDING OWNERS DEMAND: OUTSTANDING DURABILIT AND LOW LIFE-CCLE COST. TRUST FIRESTONE TO BRING OU THE DEPTH OF RESOURCES TO ENSURE THE RIGHT SSTEM FOR OUR NEEDS, WHETHER FOR ONE BUILDING OR MAN. A TRUE SINGLE SOURCE FOR ALL OUR ROOFING NEEDS MANUFA CTUR ING 19 facilities throughout North America PRO D UCTS Offers EPDM, TPO, APP/SBS modified bitumen roofing systems, metal roofing systems and a full line of accessories QUALIT CONTR O L ISO 9001/ISO 14001 certifications E PERTISE Installation experts and product support, plus a wide-ranging network of contractors, distributors and field sales representatives STA BIL IT A N D INNOVATION More than 100 years of success in rubber polymer technology RESOUR C E S Part of Bridgestone/Firestone, the world s largest tire and rubber company offering a broad depth of raw materials availability for your convenience R&D COMMITMENT Annually invests millions of dollars in research and development G REEN FOCUSED Plays a global role in protecting the environment by focusing on recyclability, reflectivity, conservation and sustainability including the elimination of PvC membrane.

F I RESTONE ROOFING S STEMS A Full Line of Products Designed to Perform and Endure FIRESTONE RUBBERGARD EPDM The most popular material for both new and reroof low-slope roofing applications. RubberGard EPDM provides outstanding durability and low life-cycle cost, along with design versatility and ease of installation. FIRESTONE ULTRAPL TPO White reflective surfaced UltraPly TPO conforms to the EPA s ENERG STAR requirements. UltraPly or ReflexEON TPO provide enhanced puncture, tear and abrasion resistance, as well as outstanding resistance to degradation from Ultraviolet (UV) radiation, ozone and chemical exposure. FIRESTONE APP AND SBS MODIFIED BITUMEN APP and SBS Modified Bitumen asphalt-based systems are available with smooth or granule surfaces. The diverse Firestone asphalt product line offers flexibility in roof design for specifiers and building owners. FIRESTONE UNA-CLAD METAL For steep slopes, Firestone offers metal roofing systems for both new construction and reroofing applications. In addition, Firestone offers multiple roof edge and coping systems for low-slope applications. A variety of metals, profiles and colors are available to meet inventive architectural needs.

Code Compliance Firestone polyiso insulations bear a variety of code body compliances noted below: Factory Mutual (FM) approved for Class 1 insulated steel deck construction. (Tested to FM 4450 standard) Foamed plastic for built-up roof covering classified by Underwriters Laboratories, Inc. (UL), as to an external fire exposure only (per UL-790) Foamed plastic classified by UL as roof deck construction material with resistance to internal fire exposure for use in Construction Nos. 120 and 123 (tested to UL 1256) UL Design numbers: P225, P230, P232, P259, P302, P508, P510, P514, P519, P701, P710, P 713, P717, P718, P719, P720, P722, P723, P727, P728, P729, P730, P732, P741, P801, P814, P815, P818, P819, P824, P828 Federal Specifications: HH-I-1972/ Gen. and HH-I-1972/2 ASTM C-1289 Based on current UL and FM test data, Firestone ISO 95+ GL complies with the IBC when installed in accordance with UL and/or FM requirements. Firestone ISO 95+ GL insulation also meets Metro-Dade 03-0123.03 and Canadian standards CGSB-15.26-M86. National Research Council of Canada (NRC) Evaluation Listing CCMC 13274-L.

Firestone Building Products 250 West 96th St., Indianapolis, IN 46260 Corporate Office: 1-800-428-4442 317-575-7000 Firestone Building Products Canada 2835 Argentia Rd., Unit #2 Mississauga, ON L5N 8G6 1-888-292-6265 905-363-3150 Fax: 877-666-3022 International Offices: Firestone Building Products Europe Ikaroslaan 75-1930 Zaventem, Brussels, Belgium +32 2 7114450 Fax: +32 2 7212718 www.firestonebpco.com Firestone Building Products Latin America 8200 NW 52nd Terrace, Suite #107 Miami, FL 33166 305-471-0117 Fax: 305-471-0377 Note: This brochure is meant only to highlight Firestone s products and specifications. Information is subject to change without notice. ALL products and specifications are listed in approximate weights and measurements. For complete product and detail information, please refer to the Technical Manual. Firestone takes responsibility for furnishing quality materials which meet Firestone s published product specifications. As neither Firestone itself nor its representatives practice architecture, Firestone offers no opinion on, and expressly disclaims any responsibility for, the soundness of any structure on which its products may be applied. If questions arise as to the soundness of a structure or its ability to support a planned installation properly, the owner should obtain opinions of competent structural engineers before proceeding. Firestone accepts no liability for any structural failure or for resultant damages, and no Firestone representative is authorized to vary this disclaimer. HPG Uses 100% Green Power. www.hardingpoorman.com Printed on Recycled Paper MANUFACTURED WITH 100% WIND ENERG 2011 Firestone Building Products Printed in U.S.A. Item #1234 12/11 (replaces 9/10)-01