How To Make A Power Plant Work Safely



Similar documents
EARTHING AND BONDING AT SECONDARY SUBSTATIONS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

STREETLIGHT SYSTEM GROUNDING AND BONDING

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Section Grounding and Bonding for Communications

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

TC Grounding and Bonding for Telecommunications Systems

5.2. Overview. The better method to install solderless compression connectors on power cable

CATHODIC PROTECTION SYSTEM DESIGN

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

800 Communications Circuits

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

TABLE OF CONTENT

TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

Chapter 9. Bonding and Grounding

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

A. Shop Drawing submittals shall include, but not be limited to, the following:

CDGRD-10. Grounding. Solutions For Comm/Data Applications

1. Division-16 Basic Materials and Methods sections apply to work of this section.

Grounding & Bonding Why it is done And How to Install Properly

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

GE Power Controls. MiniFORM Switchboards

Electrical Grounding. Appendix C

RAY-MAX Integrated Solar Power Strip

Session 14 Cable Support Systems

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

Minimum Standards for Data/Voice Infrastructure in New Building Construction

Raceway and Boxes for Electrical Systems Page 1 of 7

GUIDELINES TO INSTALL, OPERATE AND MAINTAIN HT CAPACITORS & IT S ASSOCIATED EQUIPMENT

SECTION PIPE HANGERS AND SUPPORTS

Understanding Shielded Cable

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

SECTION 22 LIGHTNING PROTECTION SYSTEM

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

This presentation to be used in conjunction with:

Checklist Testing and inspection without interconnection

David Brender Copper Development Association Inc. Miramar, March 8, 2013

TARIFF CODE and updates standard

Lightning Protection Introduction

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

CODE OF PRACTICE FOR EARTHING AND BONDING SYSTEM FOR SIGNALLING EQUIPMENTS SPECIFICATION NO. RDSO/SPN/197/2008 SIGNAL DIRECTORATE

GUIDELINES HAS/PDC/DESIGN DIVISION TITLE

Boiler Plan II Table of Contents

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Power Window/Power Lock Installation. To begin with you will need all the parts listed below:

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

MRI RF SHIELDING DESIGN

Video Camera Installation Guide

Standard Buccaneer - Ethernet

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

400 Series - Mini USB Buccaneer

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

1. Electrical Equipment A) Transformer

Welding. Module

ELECTRICAL INSPECTION BULLETIN (Effective )

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

LIEBERT VNSA Installation Sheet

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Mechanical Services Standard Specification Compressed Air Systems. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

1. Division 26 Section "Underground Ducts and Utility Structures" for ground test wells. 2. Division 26 Section Electrical General Requirements.

Dissimilar Metal Corrosion

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

ELECTRICAL SAFETY Information Bulletin

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

Title: Grounding and Bonding Rev-01

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Unified requirements for systems with voltages above 1 kv up to 15 kv

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

The Quality Connection. BETAflam Fire Resistant Safety Cables

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

AC and DC Drive System Installation Information

INSTALL/REMOVAL INSTRUCTIONS: WINDOW LIFT MOTOR

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Mini USB and USB 2.0-IP67 Connector System

SECTION DRY-TYPE TRANSFORMERS

MGB Chrome Bumper Conversion

FREQUENTLY ASKED QUESTIONS

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Transcription:

QCS Section 21 Part 22 Earthing and Bonding Page 1 22. EARTHING AND BONDING...2 22.1 GENERAL...2 22.1.1 Scope 2 22.1.2 References 2 22.1.3 Quality Assurance 2 22.1.4 Submittals 2 22.2 PRODUCTS...2 22.2.1 Materials 2 22.3 INSTALLATION...3 22.3.1 Installation 3 22.3.2 Testing 5

QCS Section 21 Part 22 Earthing and Bonding Page 2 22. EARTHING AND BONDING 22.1 GENERAL 22.1.1 Scope 1 This Part specifies the requirements for earthing and bonding. 2 Related Parts and Sections are as follows: This Section Part 1 General Provisions for Electrical Installations Part 2 HV and MV Factory Built Assemblies (FBA s) Part 6 Cables and Small Wiring Part 7 Conduit Part 8 Trunking Part 9 Cable Trays 22.1.2 References BS 7430 Code of practice for earthing 22.1.3 Quality Assurance 1 Design Criteria: the earthing system shall be in accordance with MEW Rules and Regulations. 22.1.4 Submittals 1 Shop Drawing and product data per Part 1. 22.2 PRODUCTS 22.2.1 Materials 1 Generally: submit full technical details and conductor size calculations of each type of cable or wire proposed submit exact route of each cable or wire proposed. products used in the earthing system shall be copper or an approved copper alloy, unless otherwise specified, and specifically manufactured for the purpose. 2 Earth Continuity Conductors: 3 Main Earth Loops: 4 Rod Electrodes: sizes shall be as specified by MEW, unless otherwise indicated, but in no case shall size be less than half that of the associated phase conductors insulation shall be of the same material as insulation in associated sub-circuits. 25 x 3 mm tinned copper tape, unless otherwise indicated. shall be the earth rod electrode type, unless impracticable to drive deep into the particular soil earth rod electrodes: 16 mm diameter steel core copper jacketed type, comprising a high strength steel alloy core with a molten welded copper covering to be 3.6 m long, in 1.2 m sections coupled by strong bronze couplers.

QCS Section 21 Part 22 Earthing and Bonding Page 3 5 Plant Electrodes 6 Earth Connectors: to be either: (i) copper; or (ii) cast iron where artificial treatment of soil is necessary because of high soil resistivity. connection of rod electrodes: shall be bolted type. 7 Removable Earth Links: to comprise a bolted copper link fixed on porcelain insulators and complete with studs, nuts and washers to take the earth tape and a bolted lug adequately sized for the final connection of the earth electrode. 8 Bolts, Washers And Nuts In Bolted Connections: 9 Earth Pit Cover 22.3 INSTALLATION 22.3.1 Installation 1 Circuit Wiring 2 Main Earth Loops (d) high copper alloy or silicone bronze. Ferrous hardware is not acceptable. shall be of heavy duty cast iron cover shall have a recessed lifting hook shall have a brass plate, engraved Electrical Earth Below. shall have a green/yellow coloured insulated earth continuity cable connecting the earth bus or earth terminal in switchboards, switchgears, motor control centres and panel boards to the motor, equipment, outlet and other device by earthing lugs. All hand rails and other metal works within 2 m of a potentially live metal surface shall be earthed. fix in mechanical equipment rooms and other areas indicated on the drawings, in convenient locations, allowing two return paths to earth fix copper tape to structure with copper or brass saddles and/or screws. Make tees and straight joints by riveting and seating make branch connections between main loop and major equipment, such as switchboards, switchgears, motor control centres and large motors, with copper tape of same size as main loop tape make other branch connections to equipment with copper conductors of size not less than half that of the relative phase conductor. 3 Removable Earth Links fix in every main earth lead to enable the electrode system to be disconnected for testing install in an accessible position, above ground as close as possible to the earth electrode. 4 Exposed Earth Cables 5 Bolted Connections: install and locate in a manner to provide maximum mechanical protection, utilising ceiling corners, suspended ceiling and webs of beams as much as possible.

QCS Section 21 Part 22 Earthing and Bonding Page 4 multiple bolt type where bare copper is bolted in connections contact surfaces shall be silver electroplated. 6 Brazed Connections: where earthing terminal connections are to be brazed to equipment, thoroughly clean metal prior to brazing and repaint impaired surfaces to prevent corrosion. 7 Connections Between Dissimilar Metals: 8 Equipment Earthing: protect by: (i) painting with a moisture resistant bituminous paint or compound, or (ii) wrapping with protective tape to exclude moisture. connect all non-current carrying metallic parts of the electrical/mechanical installation to the earthing system non-current carrying metallic parts of the electrical installation include: (i) metal conduit, cable armour, raceways, outlet boxes, cabinets, and the like (ii) exposed metal parts of apparatus (iii) enclosures, doors, grills, barriers and the like protecting or shielding electrical equipment from direct access series earthing of one piece of equipment to another is not acceptable. Each item shall be individually connected to earth system 9 Fire Fighting Equipment: 10 Motors Earthing: earth on a separate ring system. connect the motor terminal box to the relative earth loop. The terminal must be mechanically connected to the frame or, where this is not feasible extend the earthing conductor through an insulated bushed opening in the connection box and connect to the frame. 11 Main Switchboards, Switchgears and Motor Control Centres Earthing: connect the special earthing lug or busbars inside the cabinet to the main earth copper tape. connect all parts of the switchboards, switchgears and motor control centres other than live parts, to the earth bar in the board in an approved manner. 12 Distribution Boards Earthing: connect an earthing conductor from the main distribution earth busbar to an earth connector welded to the cabinet and earthing bushings on the incoming and outgoing feeder conduits. 13 Bus-Duct Feeders Earthing: connect the green/yellow coded earth busbar directly to the earth bus-bar in main switchboard with earth copper tape 14 Cable Armour Earthing: 15 Earth Rod Electrodes: Connect steel armour to the earthing system. drive extensible rods of the same diameter into the ground, either manually or by power driven hammer, to a suitable depth to obtain low resistivity in the particular soil

QCS Section 21 Part 22 Earthing and Bonding Page 5 bolt earth connectors to the top of the rods, in sufficient number to make connection with all incoming cables. 16 Earth Plate Electrodes: 17 Earth Pit: 22.3.2 Testing use where: (i) Ground resistivity is low but increases with depth; (ii) It is not possible to go deep into soil. protect terminations against corrosion. provide concrete/pvc pit complete with removable heavy gauge cast iron cover with recessed lifting hook, at the head of the earth rod, to protect the rod and allow access to connections for testing. 1 Testing earthing systems shall be done by the earth megger test. 2 The resistance of any point in the earth continuity system to the main earth electrode shall not exceed 1 ohm, unless approved otherwise by MEW. 3 Install additional earth electrodes if these figures are not met. END OF PART