Table of Contents accumet

Similar documents
UltraBasic Benchtop ph Meter Operation Manual

User Manual. Thermo Scientific Orion VERSA STAR

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

ph 200 ph-/redox-/temperature Meter Operating instructions

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

ExStik TM ph Waterproof Meters

Operating Instructions

4-Channel Thermometer / Datalogger

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Model 4510 Conductivity/TDS Meter Operating Manual

Instruction Manual Temp 4/5/6 Temperature Meter Series

User's Guide. Integrating Sound Level Datalogger. Model Introduction

USEPA Electrode Method Method 8156

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Manual Ranging MultiMeter

Portable Waterproof ph/dissolved Oxygen Meter

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Ground Resistance Clamp On Tester

RS DIGITAL THERMOMETER

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Milwaukee USER MANUAL

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

How To Program An Autodialer

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Pro1030 USER MANUAL. English

AutoRanging Digital MultiMeter

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Pavement Quality Indicator Model 300 Operator s Handbook

Instruction Manual DO 110. Hand-held Dissolved Oxygen Meter with RS 232C. 68X Rev. 0-11/05. Technology Made Easy...

Multi-Range Programmable DC Power Supplies 9115 Series

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

COASTAL AMUSEMENTS INC.

Userʼs Manual. 7 Color LCD TV & Monitor V7000

3. Enter the first five digits of desired frequency ( for MHz).

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

CAD-05 Kit GSM Auto Dialer. Owner s Manual

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

User Guide. Temperature and Humidity Datalogger. Model 42280

AR200. Refractometer User s Guide. Page 1

Operating manual. ph/cond 3400i. Tref25 nlf C TP CAL. ph/conductivity measuring instrument. ba75687e01 01/2007

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

TC-9102 Series Surface Mount Temperature Controllers

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Approach S3 Owner s Manual

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

SenTix 950 SenTix 980

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

Care and use guide. Contents. a handy solution made easy. page

OPERATIONS MANUAL. ba76143e04 09/ MultiLab DIGITAL METER FOR IDS SENSORS

Instruction Manual. For file reference, please record the following data:

Hand-held thermometer Model CTH7000

10 Multimeter. Users Manual

DC Electronic Loads 8500 series

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

AIRMoN, ph and Conductivity Field Measurement

Lab 1: The Digital Oscilloscope

ph Measurement and Control

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

Fluke 89-IV & 189 Event Logging

7 FUNCTION DIGITAL MULTIMETER

YSI Model 5000 YSI Model Dissolved Oxygen Temperature. Operations Manual

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Ground Resistance Clamp-On Tester

Troubleshooting and Diagnostics

Measuring the Conductivity of Pure Water Using USP<645>

Appendix C. Vernier Tutorial

EZ DUPE DVD/CD Duplicator

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

1. SAFETY INFORMATION

Dash 18X / Dash 18 Data Acquisition Recorder

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Thermistor Thermometer MODEL NO

LT-82 Stationary IR Transmitter

PPM Users Manual Signature Software

S100. GSM House Alarm System.

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

GSM Door Phone System

Wahl C50 Calibrator FEATURES

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Operation Manual For NDJ-8S Digital Rotary Viscometer

BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:

HP ProDisplay P19A LED Backlit Monitor. User Guide

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Wireless Data Logger Monitoring Systems

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Compact ph Measuring Instruments

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

CyberScan 6000 Series. Bench Meters. ph ph FET ORP Ion Conductivity TDS Salinity Resistivity Dissolved Oxygen BOD (OUR,SOUR)

Transcription:

AR50 USER Manual

Table of Contents accumet Introduction 4 Unpacking the Meter 5 Specifications 6 Getting Started Connectors Attaching ph and ISE electrodes Attaching Conductivity Probes 8 10 12 Using the Meter Touch Screen Operation Choosing a Channel Button Functions 14 16 18 Setup Operations System Setup ph Setup mv Setup Ion Setup Conductivity Setup 20 46 82 90 104 ph Operations Standardization Measurement 122 124 128 mv Operations Absolute mv Measurement Relative mv Measurement 130 131 131 2

accumet Table of Contents Ion Operations 132 Direct Reading with Standards Direct Reading with Blank Offset Incremental Methods Known Addition Measurement Known Subtraction Measurement Analate Addition Measurement Analate Subtraction Measurement 134 137 140 142 146 148 150 Conductivity Operations Standardization Measurement 154 158 Cleaning 160 Trouble Shooting 161 Warranty 162 Compliance 163 Appendix Determining Isopotential Points Experimentally Data Management Factory Default Settings ph Theory ISE Theory Conductivity Theory 164 165 166 167 169 174 178 Replacement Parts 183 3

Introduction accumet Thank you for selecting a Fisher Scientific accumet ph meter. This manual describes the operation of the accumet AR50 meter. The state-of-the-art meter that you have purchased is easy to operate and will guide you through the various functions by displaying easy to understand prompts. This operating manual should answer any questions that might arise in operating your meter; however, do not hesitate to call our Fisher Lab Equipment Technical Support Hotline at 1-800/943-2006 or 412/490-6260, if you need any assistance. This meter is designed to provide all the information necessary to guide you through the process of measuring ph, mv, ion concentration, or conductivity with a series of prompts on the screen. The accumet Research AR50 provides microprocessor precision in a compact benchtop design that is easy to use. One touch screen controls all procedures, letting you: Measure ph, absolute mv, relative mv, ion concentration or conductivity. Select one of three sets of standard buffer groups. Implement automatic buffer recognition. Standardize with up to five standard or custom buffers. Customize your display screen and operating parameters. Assign operator and sample identification numbers. Specify ion selective electrode type. Store 250 data points in the meter s memory or transfer data to a computer or printer. Access extensive online help with just a touch of a button. It all adds up to rapid, completely automatic, intuitive operation. 4

accumet Unpacking the Meter The following is a listing of what you should have received with your new accumet AR50 ph/mv/ion/conductivity meter. Meter with kit includes meter power supply electrode arm support bracket electrode arm electrode (13-620-285) ATC probe (13-620-19) manual and literature * Note that this meter does not include a conductivity cell. Meter only includes meter power supply electrode arm support bracket manual and literature If any of these items are missing, please contact the Fisher Products Group Electrochemistry Operation by dialing 412/490-6267. Accessory Conductivity Probes and Ion Selective Electrodes are available and can be ordered by calling Fisher Customer Service at 800/766-7000. 2-cell Conductivity Probes: Cell Constant Optimal Conductivity Range Glass Body Epoxy Body 0.1 0.5 to 200 µs/cm 13-620-156 13-620-161 1.0 0.01 to 2 ms/cm 13-620-155 13-620-160 10.0 1 to 200 ms/cm 13-620-157 13-620-162 4-cell Conductivity Probes: Cell Constant Optimal Conductivity Range Glass Body Epoxy Body 1.0 0.01 to 20 µs/cm 13-620-163 13-620-165 10.0 1 to 200 ms/cm 13-620-164 13-620-166 5

Specifications accumet Display screen size measurement display height temp/etc. display height menu options help screens configurable display keypad controls 640x480 digit LCD 4 1/2 x 6 3/4 1/4 extensive extensive yes context specific touchscreen Memory internal diagnostics programmable data storage programmable data output print interval programmable alarm 250 data pts yes store on stable, time, manual output on stable, time, manual 1 to 9,999 sec yes ph Mode range resolution relative accuracy automatic buffer recognition manual buffer recognition calibration points auto lock FET -2.000 to 20.000 0.1/0.01/0.001 ± 0.002 yes yes 5 yes yes mv Mode range resolution accuracy ± 1800.0 0.1 ± 0.1 Ion Mode range resolution relative accuracy calibration points incremental methods 1x10-6 to 9.99x10 10 0.1/0.01/0.001 ± 0.17n% 5 KA, KS, AA, AS 6

accumet Specifications Conductivity Mode cell constants range conductivity resistivity salinity accuracy 0.1, 1.0, 10 0 to 3x10 5 µs/cm 30 ohm.cm to 100 megohm.cm 2 to 42 ppt 0.5% Temperature Mode range resolution accuracy -5.0 to +105.0 C 0.1 C ± 0.2 C General inputs/outputs electrical requirements output from PSU line voltage tolerance input impedance meter size meter weight 2BNC, 2Pin, 2ATC, 2-pin cond. RS232, DIN (for FET and 4 cell cond.) 115 V/60 Hz, 230 V/50 Hz 12VDC, 500mA ± 10% >10 12 ohms 5.5 x 7.5 x 3.25 1.86 lb. Operating Conditions operating temperature operation humidity maximum operating altitude installation category Pollution category degree 5-45 C 5-80 % noncondensing 2000m II 2 7

Getting Started CONNECTORS accumet 1 Review the layout and arrangement of the rear connector panel. Conductivity Cells AccuFET ph electrode Automatic Temperature Compensation (ATC) Power Reference pin jack Computer/Printer BNC input connector POWER RS-232 Conductivity FET ATC 1 Ref 1 Input 1 2-cell Conductivity ACT 2 Ref 2 Input 2 4-cell 8

accumet CONNECTORS Getting Started 2 Connect the electrode arm to the base. electrode arm support To connect RS-232, see Data Management on page 166. 3 Connect the power cable to the rear connector panel power jack and to a power source. POWER 9

Getting Started ph and ION SPECIFIC ELECTRODES accumet This meter allows you to use two types of ph electrodes: the conventional glass ph electrode and the AccuFET field effect transistor (FET) ph electrode. If both types of ph electrodes are connected, the meter will read the AccuFET electrode. This meter also allows you to use ion specific electrodes. If both a conventional electrode and an AccuFET electrode are connected to the meter, do not put them in a solution together because you will get inaccurate measurements. 1 Carefully remove the protective cover from the end of the electrode. Before first using your glass ph electrode, or whenever the electrode is dry, soak it 2-4 hours in an electrode storage solution, ph 4 Buffer, or KCl solution. Before using your ion specific electrode, consult the manufacturer s instructions for electrode preparation. 2 Remove the shorting cap on BNC connector. Connect the combination ph electrode by plugging it into the BNC input connector (twisting to lock in place). If a combination electrode isn t used, connect the indicating ph electrode into the BNC input connector. Plug the reference electrode into the reference pin jack. Also, install the ATC probe into the ATC jack. Note: Be sure to connect all probes to the appropriate channel connectors (for example: Input 1, Ref 1, and ATC 1). Do not discard the BNC shorting cap. Option: Connect the optional AccuFET electrode by plugging it into the FET jack on the back meter panel. Allow the AccuFET to warm up five minutes before use. Connect ion specific electrodes in the same manner as ph electrodes. 10

accumet ph and ION SPECIFIC ELECTRODES Getting Started 3 Rinse and blot-dry (don't wipe) electrodes between each measurement. Rinse electrodes with distilled or deionized water, or a portion of the next solution to be measured. Proper electrode care is fundamental to obtaining reliable ph measurements. Improper care of the electrode may cause the meter reading to drift, respond slowly, or produce erroneous readings. For this reason, the electrode should always be conditioned and used in accordance with manufacturer s instructions. 4 Between measurements, store conventional ph electrodes in electrode storage solution, ph 4 buffer, or KCl solution. Always leave the filling hole of liquid filled combination electrodes open. Refill when the level of solution gets below the manufacturer s recommended level. Store ion specific electrodes according to electrode manufacturer s recommendations. 11

Getting Started CONDUCTIVITY PROBES accumet This meter also allows you to use two types of conductivity cells: the 2-cell conductivity cell with dual pin connector and the 4-cell conductivity cell with DIN connector. The 2-cell conductivity probe works in channel 1 and the 4-cell conductivity cell works in channel 2. 1 Carefully remove the protective cover from the end of the conductivity cell. Before using your conductivity cell, soak it for 5 to 10 minutes in distilled or deionized water. 2 Connect the 2-cell conductivity cell to the 2-cell jack. Install the ATC probe in the ATC-1 jack. OR Connect the 4-cell conductivity cell to the 4-cell jack. The 4-cell accumet conductivity cells have built in ATC probes. Therefore, there is no need to install a separate ATC probe. 12

accumet CONDUCTIVITY PROBES Getting Started 3 Rinse and blot-dry (don't wipe) probe between each measurement. Rinse probe with distilled or deionized water, or a portion of the next solution to be measured. 4 Between measurements, store conductivity probes dry. 13

Using the Meter accumet TOUCH SCREEN OPERATION Standby screen Fisher Scientific 11:11am Touch anywhere to resume 14

accumet TOUCH SCREEN OPERATION Using the Meter The new accumet Research benchtop ph meters operate with a state-of-the-art touch screen. The touch screen makes this the easiest meter on the market to operate and care for. When the meter is first plugged in, the STANDBY screen will appear. Touch anywhere on this screen to access the functions of the meter. The buttons on the right side of the screen control all of the functions of the meter. A light touch on the screen is all that you need to access the various functions. Once you touch a button you will get an audible tone; the screen will not change until you lift your finger. This design prevents rapid uncontrolled scrolling through the various function screens. Function buttons and options change from screen to screen. Easy to understand prompts guide you through the operation of the meter in the selected mode. If you are ever in doubt about what to do, just touch help on the bottom right corner of the screen for detailed information about that screen. The touch screen is made of a durable polyester material that is chemically resistant. Maintenance is simple with this meter. To clean the screen you just need to wipe it with a damp cloth and dry it with a clean dry towel. For additional information, see cleaning and troubleshooting sections of the manual (pages 160-161). 15

Using the Meter accumet CHOOSING A CHANNEL Main screen Channel screen Fisher Scientific ph Fisher Scientific 1 accumet AR50 mv accumet AR50 2 Ion dual Select from the options to the right Cond Select your desired measurement channel setup stdby September 17, 1997 11:11am channel September 17, 1997 11:11 am help Dual screen Measure ph ID# auto buffer auto read us/cm channel 1 9.295 00000 ATC 26.2 C ON slope 000.0% ON mv 0000.0 BUFFERS Last std: Sep 17 @ 10:17 am September 17, 1997 11:11 am channel 2 0.010 1 2 print stdby ID# Cell K STND 00000 ATC 26.2 C Ref 25 C 1.00/cm Co 0.00%/ C Last std: Sep 17 @ 10:10 am help 16

accumet CHOOSING A CHANNEL Using the Meter The accumet Research AR50 is a Multi-channel ph meter. With this meter you can switch from channel 1 to channel 2. You can also view both channels at the same time by accessing the dual channel mode. If you set the meter to view both channels, you cannot change the parameters without choosing the screen that you want to modify. The setup parameters for each screen are setup independently of one another. Choosing a Channel 1 Touch anywhere on the Standby screen. OR Touch channel on the main screen. THEN 2 Touch 1, 2 or dual to access the channel that you want to view. To access System Setup from the Standby screen 1 Touch anywhere on the Standby screen. If you are in any measure mode, touch mode until you access the main screen. 2 Touch 1 or 2 on the channel screen to access either channel. 3 Touch setup. 4 Touch system on the Setup screen. 17

Using the Meter BUTTON FUNCTIONS accumet The touch screen of your accumet Research ph meter has buttons along the right side of the screen that are common to many of the screens. The following indicates the function of these common buttons. stdby channel mode enter save This is the standby button and it allows you to access the standby mode. When in standby, the meter will not take measurements. It is in a state of rest. When you touch stdby the meter will return to the standby screen which says Fisher Scientific and displays the time. This button allows you to access the channel screen to choose what channel you want to view. This button appears only on multichannel meters such as the accumet AR25 and AR50. This button also allows you to move from the main mode screen to the channel screen to access the standby mode. The mode button allows you to switch between the various operations of the meter. These operations, depending upon which meter you have, include four measuring modes (ph, mv, ion, conductivity) as well as a setup mode. The enter button allows you to accept any changes that you have made on setup screens or accept values that you have input with keypads. When touched, enter will save the changes and return you to the previous screen. The save button allows you to save multiple changes you have made on one screen as a group. It functions like the enter button does for individual changes. exit help close The exit button allows you to leave the screen you are currently viewing and return to the previous screen without making any changes. The help button allows you to access helpful information on any screen. When you touch the help button, information about the current screen appears. This information will include step-by-step instructions for operating the meter from the current screen and possible applications information for that screen. The close key appears on the bottom of all help screens and allows you to exit the help screen and return to the previous screen. more The more button appears on the help screens and allows you to advance to the next help screen for additional information. back The back button appears on the help screens and allows you to move back to a previous help screen. 18

accumet BUTTON FUNCTIONS Using the Meter std This button accesses the standardization screen from the various measure modes and initiates standardization of the meter once the standardization screen is accessed. meas This button is the measure button and directs the meter to measure your sample when in the Auto Read function of the ph or Ion modes. setup print This button will access the setup screens for the measuring mode that you are currently using. It can also be used to access the system setup screen that allows you to set parameters that are not related to measurements such as the time and the date. The print button will send information to the output device that you have connected to your accumet meter. The output device can be a printer, data logger or a computer. In addition to this, touching the print button will also send data to the data storage center of the meter if a sample ID# has been assigned to your sample. The arrow keys on the screen move the cursor up and down in order to highlight parameters that you would like to review or edit. edit clear BS The edit button appears on the setup screens. After you have highlighted a parameter that you would like to change, the edit button allows you to access the available options for that parameter. The clear button allows you to remove a setup parameter or standard buffer value from the meter s memory that may have been entered at a previous time or by a previous user that is no longer of value to you. Touching the clear button erases the value so you may enter a new one. It can also erase a parameter that you may have entered erroneously. The BS button is a backspace button. It appears on keypad screens and it allows you to back up and delete a character entered in error. delete The delete button appears on the View Stored Data screens. This button allows you to erase the data from the memory of the meter. prev next The prev button appears on the Data Screens when the data stored in the meter s memory has been accessed. It allows you to scroll through data points sorted and stored prior to the current data point displayed. The next button appears on the Data Screens when the data stored in the meter s memory has been accessed. It allows you to scroll through data points sorted and stored after the current data point displayed. 19