Instruction Manual. For file reference, please record the following data:
|
|
|
- Jonathan Crawford
- 9 years ago
- Views:
Transcription
1 Instruction Manual Series B9 and C9 Electronic Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your LMI Series B9 and C9 Metering Pump or Accessory, please include complete Model Number and Serial Number of your unit. 201 Ivyland Road Ivyland, PA EL: (215) FA: (215) Replaces same of Rev. B 11/ C 6/10
2 Contents 1.0 Introduction Unpacking Features How to Interpret the Model Number Pre-Installation/Installation Instructions Accessories Keypad/Display Description and Function LCD Screen Start/Stop Up/Down Mode Key Operation Pump Start/Stop Speed Priming Pressure Level Control Keypad Lock Low Level Switch External Control Modes Programming the Pulse Divide Value Programming the Pulse Multiply Value Programming the ma Response Programming Points 1 and 2 (SPM) Programming Points 1 and 2 (SPH) Advanced Features and the Setup Menu Accessing the Setup Menu Menu Items Batch Accumulate Computer Communication Automatic Voltage Compensation Flow Monitoring Input Signal Pulse Width (Debounce) Integral Blowdown Appendix A: Input/Output Descriptions Appendix B: Summary of Error Messages
3 1.0 Introduction he Series B9 and C9 electronic metering pumps offer an extensive range of features, including microprocessor control for accurate and flexible automation in response to instrument signals. he microprocessor design employs a customized liquid crystal display (LCD) and tactile response keypad. he state-of-the-art surface mount electronics are fully encapsulated to ensure protection in its working environment. All external inputs and outputs are opto-isolated from the microprocessor. his manual supplement describes programming and operation. It also describes details of the pumps external inputs and outputs and how they are connected. For complete details on Installation, Maintenance and roubleshooting, please refer to Electronic Metering Pumps Manual (P/N 1615). Figure 1: LMI Series A9 Electronic Metering Pump 3
4 2.0 Unpacking Please reference Section 2.0 Unpacking Check List found in the instruction manual Electronic Metering Pumps 1615.R. 4
5 3.0 Features Stroke frequency adjustment from 0 SPH (strokes per hour) to 100 SPM (strokes per minute) Internal (manual) or external mode select Flexible slope adjustable response to ma input signals Divide or multiply (batch) incoming pulses (1 to 999) Batch accumulate option Integral blowdown controller feature Keypad locking Low-level shutoff with alarm output Programmable flow monitoring with alarm output (with FM Digi-Pulse ) 6-level pressure control Continuous non-volatile memory (EEPROM)--no battery required Remote ON/OFF control Pulse (pacing) output Automatic line voltage compensation and over voltage protection Programmable menu for optional features/parameters Serial communication interface option for computer control (LiquiComm ) 5
6 4.0 How to Interpret the Model Number he silver data plate (located on the front of the pump) tells you how your pump is configured. Figure 3a : Data Plate Included on the data plate is the model number of the pump. Each number in the model number represents the following in Figure 3b. A S A9- Series or Model Liquid End Output Codes Cord & Voltage Codes 1 = 120 V US plug 2 = 240 V US plug 3 = 230 V DIN plug 5 = 240 V UK plug 6 = 250 V Aust/ NZ plug 7 = 230 V Swiss plug Figure 3b : Part Number Representation 6
7 5.0 Pre-Installation and Installation Instructions Specific precautions should be taken when working with all LMI metering pumps. Please read Section 3.0 in the Electronic Metering Pumps manual (P/N 1615) for pre-installation instructions. For complete installation instructions, see Section 4.0 in the same manual. 7
8 6.0 Accessories DIGI-PULSE LEVEL SWICH Low Level Input Flow Monitor Input 8 Pin Connector 4 Pin Connector Figure 4: External Input and Output Connections For specific descriptions of pump inputs and outputs, see Appendix A in the rear of this manual. 6.1 MilliAmp Input Cable (P/N 33807) Each pump includes a 2-conductor cable assembly which connects to the 8-pin connector. It is available for pacing in response to a 0 to 20 ma (4-20 ma) instrument signal only. Figure 5: 2-Conductor Cable (P/N 33807) PIN WIRE SIGNAL 3 White ma (+) Input 4 Black ma (-) Input able 1: Pin Out able - milliamp Input Cable 8
9 6.2 Optional 4-Pin Cable (P/N 33796) he optional 4-pin external cable is used for connecting incoming pulse or pacing signals such as those triggered by a manual switch, reed switch, opto-coupler or by NPN or PNP transistors. he remote ON/OFF input is also accessed through the standard 4-pin connector. Figure 6: 4-Pin Cable (P/N 33796) PIN WIRE SIGNAL 1 White +15V Output 2 Black Pacing input 3 Green +15V Ground 4 Red Remote ON/OFF & Computer Input able 2: Pin Out able - 4-Pin Cable (P/N 33796) 9
10 6.3 Optional 8-Pin Cable ( P/N 33738) he optional 8-pin external cable assembly can be used to control stroke frequency in response to a 0 to 20 ma or 4 to 20 ma instrument signal. It provides an input for flow monitoring. his cable assembly also provides output signals for pacing (pulse output), alarm (general) and computer alarm. If a 0 to 20 or 4 to 20 ma signal is the only signal functioning, it is suggested that you use the Milliamp Input Cable, which is discussed on page 8. Figure 7: 8-Pin Cable (P/N 33738) PIN WIRE SIGNAL 1 Red +15V Output 2 Black +15V Ground 3 Violet or 4-20 ma (+) Input 4 Green or 4-20 ma (-) Input 5 Orange Pulse Output 6 Yellow Alarm Output 7 Brown Flow Input 8 Blue Computer Alarm Output & Computer Output able 3: Pin Out able - 8-Pin Cable (P/N 33738) 10
11 S R O K E S R O K E MICROPROCESSOR DOSING PUMP Optional Hall Effect Cable (P/N 33833) An optional cable assembly is available for pacing your pump directly from an LMI Flowmeter fitted with a Hall Effect sensor. his cable connects to the Flowmeter as shown in Figure 8 (there is no need for a Programmable Divider; its function is built into the pump). LMI pump MICROPROCESSOR DOSING PUMP LMI Flowmeter P/N Figure 8: Optional Hall Effect Cable (P/N 33833) 6.5 LiquiComm Computer Interface Package he optional LiquiComm package may be used to control and monitor up to 32 pumps from a computer over a serial RS485 interface as shown in Figure 9. Please contact LMI for further details. Series A9 Pump Interface Box Figure 9: LiquiComm Computer Interface 11
12 7.0 Keypad/Display: Description and Function MICROPROCESSOR DOSING PUMP ma E : IN FLOW P12 I N S R O K E MODE E SOP SAR HOLD O PRIME Acton, MA U.S.A. 50/60 HZ 230V MODEL SERIAL MA/L/H OUPU.7 AMP A S MA/BAR 3.79 PRESS 7.6 Figure 10: A9 Keypad 7.1 LCD Screen he LCD screen is the window in which all values and menu choices are displayed (see Figure 11). MILLIAMP MODE INDICAOR EERNAL/INERNAL MODE INDICAORS PULSE MULIPLY/DIVIDE MODE INDICAORS ma E IN FLOW P12 : SPEED (Pulse min/hr) FLOW MONIOR FUNCION INDICAOR PUMP SYMBOL (when pump is on) POIN 1 AND POIN 2 MILLIAMP RESPONSE INDICAORS Figure 11: Liquid Crystal Display 12
13 7.2 Start/Stop SOP SAR he SOP (Start/Stop) key turns the pump on or off. If the pump SAR is not running, pressing this key will cause the pump to start running. he symbol appears on the display while the pump is running. Each time the pump strokes, the symbol clears. If the pump is running, pressing the the pump. he SAR pump as described on page 15. SOP (Start/Stop) key will stop SAR SOP (Start/Stop) key is also used to prime the 7.3 Up and Down Key Use the (Up) and (Down) keys when: changing the stroke frequency; altering the pressure level; activating and deactivating the keypad lock; programming the divide and multiply values and milliamp response; accessing the setup menu; and changing certain parameters included in the setup menu. All of these functions are covered in greater detail later in this supplement. 7.4 Mode Key I N MODE E MODE Use the I E N (Mode) key when: changing to or from external or internal mode; accessing the pressure level; activating and deactivating the keypad lock; and accessing specific advanced features in the setup menu. 13
14 8.0 Operation of the Series A9, B9, and C9 hese pumps feature EEPROM nonvolatile memory. he pump will always power up in the last used mode. When shipped from the factory the pump will power up in the Internal (manual) mode, with the pump OFF and a speed setting of 100 SPM. If the power to the pump is cut less than 15 seconds after the last programmed values have been set, the latest changes will NO be stored in nonvolatile memory. Allow at least 15 seconds before disconnecting from power to ensure that the latest changes are stored. 8.1 Pump Start/Stop Press the SOP (Start/Stop) key to start or stop the pump. When the SAR pump is OFF, the LCD screen will alternate between IN and IN every 16 seconds. When you start the pump, the symbol appears on the LCD the symbol disappears. Press the to stop the pump. IN. Each time the pump strokes, SOP (Start/Stop) key again SAR IN signifies that the pump is in the Internal (Manual) mode. 14
15 8.2 Speed he speed may be changed with the pump ON or OFF. o increase or decrease the speed, press or hold the (Up) or (Down) key. he range runs from 0 SPH to 100 SPM. While normally the speed will be set in SPM, if settings of SPH are desired, hold the (Down) key until the display reads 0, then continue to hold it for an additional three (3) seconds. he display will then show H60, which is 60 SPH. he speed can be further reduced to 0 SPH with the (Down) key. For example: IN IN +3 sec IN 8.3 Priming he priming function allows a fixed-time prime period of one (1) minute and enables priming of the pump in either Internal or External control modes. he priming function overrides the need for an external signal to cause the pump to stroke while in the External mode. Press and hold the (Start/Stop) key SOP for three SAR (3) seconds. he pump will start running at a speed of 60 SPM. If desired, alter the speed as noted above. he pump will stop one (1) minute from the time the SOP (Start/Stop) key was last pressed, or SAR you can stop the pump by pressing the SOP (Start/Stop) key again. SAR he display alternates between the pump speed and. Flow Monitoring (see page 26) is inactive in the Prime mode. 15
16 8.4 Pressure Level Control he maximum pressure rating of your pump can be adjusted to reduce pulsation shock in your discharge line. he pumps have a 6- point pressure control scale. he minimum setting is 0 and the MODE maximum is 5. o access the pressure setting, press the I E N (Mode) key and (Up) key at the same time and hold for two (2) seconds. he current pressure setting may be altered using the (Up) or (Down) keys. he pressure may be changed with the pump ON or OFF and in either Internal or External mode. 8.5 Keypad Lock he pump has two (2) lock modes to prevent casual tampering. he small LOC de-activates all key functions except SOP (Start/ SAR MODE Stop) and Prime. o activate this LOC mode, press the I E N (Mode) key and (Down) key at the same time and hold for two (2) seconds. he LCD will read for five (5) seconds and then return to the previous display. his display re-appears when any key except the SOP (Start/Stop) key is pressed. SAR he large LOC disables all keypad entries, including Start/Stop. Activate this by pressing the Mode, Down, and Up keys at the same time and holding for two (2) seconds. he LCD will read for five (5) seconds and then return to the previous display. his display re-appears whenever any key is pressed. 16
17 MODE o de-activate either lock mode, press the I E N (Mode) key and (Down) key at the same time, and hold for two (2) seconds. he or will disappear. 8.6 Low-Level Switch (P/N or 29190E) When the Low-Level Switch is fitted to the pump and a fault condition exists, the E1 error code will flash on the LCD screen IN. For more information on the Low-Level Switch, see the Low- Level Switch Assembly information sheet (P/N 1368) and page 30 of this supplement. When a fault condition exists, the pump is stopped and the alarm and computer alarm lines are activated to allow remote monitoring. After clearing the fault (by filling the tank), the pump will automatically restart. 9.0 External Control Modes o access the pulse divide, pulse multiply or milliamp response, the pump must be changed from Internal (manual) mode to External mode. o do this, first be sure the pump is stopped. Press the I N MODE E (Mode) key and hold it for three (3) seconds. he LCD screen displays the last External mode that was programmed. If this is the first time the pump has been put in the External mode, the factory default will be displayed on the LCD screen. he factory default mode is External Pulse Divide with a divide value of one (1) E :. he display will alternate between SPM and OFF. 17
18 External Mode Select: Pulse Divide, Pulse Multiply, and ma Response Any of three external modes may be selected when the pump is MODE stopped by pressing and holding the I E N (Mode) key and SOP (Start/Stop) key for five (5) seconds, then releasing. As noted above, the default is Pulse Divide. Pressing and releasing these E keys brings you to the Pulse Multiply mode. In this mode, the LCD screen alternates between the pulse multiply value and OFF. Pressing and releasing these keys one more time brings you ma E to the third external mode, ma response. In this mode the LCD screen alternates between SPM and the ma value. SAR Summary of External Mode Select I N MODE + E SOP SAR For 5 Seconds : E I N MODE + E SOP SAR For 5 Seconds ma E I N MODE + E SOP SAR For 5 Seconds E 9.1 Programming the Pulse Divide Value he divide value is altered by using the ( Up) and (Down) keys. o do this, the pump must be in the External Divide mode and be OFF. he valid range for the divide value runs from 1 to 999. With the pump running in the Divide mode, the speed in SPM is calculated based on the rate of incoming pulses and the divide E value, and displayed on the LCD screen :. 18
19 If the calculated speed is less than one (1) SPM, the LCD screen will display 0 SPM. If the calculated speed is GREAER HAN 100 SPM, the E3 error code will be displayed periodically until the fault condition is corrected E :. his error does NO activate the alarm outputs or stop the pump. 9.2 Programming the Pulse Multiply (Batch) Value he multiply value is altered by using the (Up) and (Down) keys to change the value. he pump must be OFF and in the External Multiply mode. Like the divide value, the valid range for the multiply value runs from 0 to 999 pulses. When the pump is ON, a single external pulse will initiate a batch of pump strokes. he number of remaining pulses are displayed on the LCD screen E. When 0 is reached, the display resets to the multiply value. he pump is now ready for another pulse input. If a pulse is received before the countdown to 0 is complete, the E4 error code is displayed, and the pump batch count resets to the programmed multiply value. he batch countdown then continues from its programmed value. As the countdown continues, the E4 E error code will be displayed intermittently until the fault is corrected. he strokes that remained from the first batch are NO accounted for. o clear the fault display, the pump must be stopped and restarted. o allow true flow proportioning, the speed in the Multiply mode is equal to the speed set in the Internal (manual) mode. hat is, if the Internal mode speed is set at 60 SPM, in the External Multiply mode the pump counts down at 60 SPM. 19
20 Batch Accumulate he Batch Accumulate function allows you to opt to have any extra input pulses received in the multiply mode accumulate up to a maximum batch of 999. If Batch Accumulate is enabled and a pulse is received during the countdown, the programmed multiply value will be added to the current displayed value. Pulses causing the maximum batch of 999 to be exceeded will result in an E4 error message. When Batch Accumulate is enabled, the LCD screen alternates between the current multiply E value and ACC. he Batch Accumulate function is activated in the Setup Menu (see Advanced Features and Setup Menu on page 25). 9.3 Programming the ma Response he pump accepts a 0-20 ma or 4-20 ma signal directly. he response to this signal is fully programmable. In the ma mode, the pump speed is determined by the programmed response curve, as defined by points P1 and P2. he factory default set values for P1 and P2 are (4 ma, 0 SPM) and (20 ma, 100 SPM) respectively. his is illustrated in Figure 12. While in the ma mode, the pump speed ma pump is running. ma E and the ma value are displayed alternately every four (4) seconds while the 9.4 Programming Points 1 and 2 (SPM) o program points P1 and P2, first ensure the pump is in the ma mode and OFF. If you wish to program the response in SPM, 20
21 switch to the internal mode. he speed must be set to a SPM value IN. Return to the External ma mode. ma P1 P1 and ma P2 P2 100 P2. SPM P ma 20 Figure 12 Press either the (Up) or (Down) key. he LCD screen will display. After five (5) seconds, the display will show the ma value for P1 ma. his value may be altered using the P1 (Up) or (Down) key within five (5) seconds (i.e. ). Five (5) seconds following the last key press, the stroke rate for P1 will be displayed. his value may be altered within five P1 (5) seconds using the Up or Down key (i.e. ). Five (5) seconds after the last key press, the ma value for P2 is ma displayed. Edit as described in the above paragraph (i.e. P2 ma ). Likewise, five (5) seconds after the last key press the P2 stroke rate for P2 is displayed. Edit as described above (i.e. ). 21
22 he above examples would result in the inverse control profile shown in Figure SPM 10. P1 P ma Less than 0.5 ma SPM=0 Figure 13. If the ma input goes below the value programmed for P1 or above the P2 value, the response will plateau, as indicated by the dotted lines above. he valid input range is from 0.5 to 21 ma. Below 0.5 ma, the pump will be off. Above 21 ma, the E5 error code will be displayed intermittently. 9.5 Programming Points 1 and 2 (SPH) If you wish to program the response in strokes per hour, start by being in the External ma mode. Next, switch to the Internal mode. If the Internal setting is in strokes per minute, change to strokes per hour by holding the (Down) key until the display reads 0 SPM. Continue to hold it for another three (3) seconds. he display will now read SPH IN. Set the speed to any SPH value (the actual setting has no bearing on ma response). Return to the External ma mode. 22
23 In the External ma mode, pressing the (Down) key or (Up) key will change the display to. After five (5) seconds, the display will show the ma value for P1. his value may ma P1 be altered by using the (Up) key or (Down) key within five (5) seconds (i.e. ). Five (5) seconds following the last key press, the stroke rate for P1 will be displayed. his value may be altered within five (5) seconds using the (Up) or (Down) key (i.e. ). Five (5) seconds after the last key press, the ma value for P2 will ma ma be displayed. Edit as described above (i.e. ). P2 P2 Likewise, five (5) seconds after the last keypress, the stroke rate for P2 is displayed and may be altered as above (i.e. ). P2 he above example would result in the inverse control profile shown in Figure SPM 10. P ma Less than 0.5 ma SPM=0. P2 Figure 14 he valid input range is from 0.5 to 21 ma. Below 0.5 ma, the pump will be off. Above 21 ma, the E5 error code will be displayed intermittently. When programming strokes per hour, the maximum rate is 60. P1 and P2 must BOH BE SPM or BOH BE SPH. 23
24 10.0 Advanced Features and the Setup Menu Advanced features such as Batch Accumulate, Computer Interfacing, Automatic Voltage Compensation, Flow Monitoring and Integral Blowdown may be selected and altered in the Setup Menu of the Series A9, B9, and C9. he following configuration chart describes each menu item, its description, and available settings. Menu Description/ Item Function Setting Notes Software Revision Read Only 1 Batch Accumulate 0 = Disable Applies to External Multiply mode 1 = Enable 2 Computer 0 = Disable Allows computer interface to be Communication 1 = Enable established with LiquComm software. Remote Start/Stop and Computer Alarm lines are used in communication. 3 Automatic Voltage 0 = Disable Becomes active two (2) minutes after Compensation 1 = Enable power up. 4 Flow Monitoring 0 = Disable Used in conjunction with FM = Enable Digi-Pulse Flow Monitors. Flow displayed and flashes with each pulse from FM Flow Monitoring 1 to 255 Sets the number of missing pulses before Pulse Detection alarm output is activated. Menu item Pulse Detection Setting number is not included with LCD display. his setting is displayed irrespective of Menu Item 4 setting. 6 Input Pulse Width 0-15 Allows pulse widths of 1 to 60 msec to be set. Setting of 0 gives a debounce time of approximately 1 msec. 7 Integral Blowdown 0 =Disable Allows Activation of the integral blowdown 1 =Enable feature. 8 Integral Blowdown 0 to 255 Set solenoid ON time in seconds. Solenoid ON ime (Seconds) 9 Integral Blowdown 0 to 255 Set pump ON time in seconds. Pump ON ime (Seconds) Note: Allow 15 seconds after programming before disconnecting from power to ensure latest changes are stored in nonvolatile memory. 24
25 10.1 Accessing the Setup Menu o access the Setup Menu, ensure that the pump is OFF and in the Internal mode. Using the (Up) key, bring the stroke rate to 100 SPM. At this point, keep the (Up) key pressed for five (5) seconds. he LCD screen then displays the current software revision, indicating that you have entered the Setup Menu mode. Press the I N MODE (Mode) key to scroll through the Menu Items. Use E the (Up) or (Down) key to enable or disable menu functions and program values. o exit the Menu mode, press the SOP (Start/Stop) key. Or, if no SAR keys are pressed for 13 seconds, the display reverts to IN Menu Items Menu Item 1: Batch Accumulate Enable/Disable Batch Accumulate may be enabled (1) or disabled (0). Use the (Up) or (Down) key to change the selection Menu Item 2: Computer Communication Press the Mode key to get to Menu Item 2, Computer Communication. Setting the value to one (1) enables computer communication using the LiquiComm Interface Box and Software. 25
26 When Computer Communication is enabled, the Remote Start/ Stop and Computer Alarm lines are deactivated and used for the computer communication link Menu Item 3: Automatic Voltage Compensation Menu Item 3 enables (1) or disables (0) automatic voltage compensation. his unique feature allows a constant power level to be delivered to the EPU of the pump, even when the voltage of the external power source is fluctuating. his results in smooth pump output in spite of fluctuating voltage and prevents overheating. Automatic voltage compensation becomes active two minutes after power up Menu Items 4 and 5: Flow Monitoring his feature is used in conjunction with the LMI Series FM Digi-Pulse Flow Monitor (refer to Digi-Pulse Flow Monitor Instructions P/N 1708). his device is designed to monitor the output flow from a pump. It may be set to deliver a pulse signal output for each successful pump stroke registered. If the flow stops or lessens, the pulse outputs will cease. With the FM connected to the flow monitor input, the presence or lack of pulses can be detected (see Figure 15). FM Digi-Pulse FM Flow Monitor Digi-Pulse Flow Monitor Series A9 Pump Figure 15 26
27 MODE Press the I E N (Mode) key a fourth time and then the (Up) or (Down) key to allow flow monitoring to be enabled (1) or disabled (0). When flow monitoring is enabled, Flow is MODE displayed on the LCD screen. Again, pressing the I E N (Mode) key displays the number of missing pulses to be detected. his may be set to any value from 1 to 255. he factory default is 8. A setting of 1 is the most sensitive, a setting of 255 the least sensitive. For example, if the setting is 5, and five (5) strokes of the pump occur without any pulse being received from the FM-200-9, the LCD screen will display an E2 error code. he pump will stop, and the alarm outputs will be activated (i.e. IN FLOW ). Pressing the SOP (Start/Stop) key clears the error. SAR he word Flow blinks every time the A9, B9, or C9 receives a signal from the Digi-Pulse. his serves as an aid in setting up the Digi-Pulse itself Menu Item 6: Input Signal Pulse Width (Debounce) Menu Item 6 determines the debounce period (pulse width) to be applied to incoming pulse (pacing) signals. he default value is 15, which corresponds to a debounce value of 60 msec. Each unit corresponds to approximately 4 msec. his means that in order to be recognized, an input signal must be at least 60 msec in duration. his setting may need to be reduced from its maximum setting for high frequency input pulse signals such as those from a Hall Effect flowmeter. 27
28 Menu Items 7, 8 and 9 Activate the Integral Blowdown Feature hese Menu Items will require additional accessories and customer supplied components. For complete details please refer to A9, B9 and C9 with Integral Blowdown (P/N 1753). his Integral Blowdown feature provides cooling tower control from your LMI microprocessor pump when used in conjunction with a pulse output type flowmeter (batch mode) or 4-20 ma signal (milliamp mode). hese signals can then be input into the pump to provide activation of both the pump and a customer supplied solenoid valve. LMI s Relay Pack, Model RP-100A, must be ordered separately to provide power to the customer supplied solenoid. A. Batch Mode Programming Menu Menu Item 1 Batch Accumulate: Select 0 = (Disable) or 1= (Enable) Menu Item 7 Integral Blowdown: Select 1 = (Enable) Menu Item 8 Solenoid ON time: Select 0 to 255 (Seconds) Select IN mode and set the manual strokes per minute. Select E (multiply) mode (batch mode) and program stroke count. On receipt of a pulse from the flowmeter, the pump strokes the programmed number of pulses. he batch value (multiply [] value) and manual SPM determines the length of time the pump will be on. 28
29 On receipt of a pulse from the flowmeter, the solenoid valve is opened. he solenoid remains open for the length of time programmed in Menu Item 8. If another flowmeter pulse is received before the above is completed the solenoid ON time is extended by the time programmed in Menu Item 8. B. Milliamp Mode Programming Menu Menu Item 7 Integral Blowdown: Select 1 = (Enable) Menu Item 8 Solenoid ON time: Select 0 to 255 (seconds) Menu Item 9 Pump ON time: Select 0 to 255 (seconds) Select E ma mode (milliamp mode) and program the ma response (Point 1 and Point 2). he pump strokes at a rate determined by the ma input signal for the length of time determined by Menu Item 9. he solenoid remains open for the length of time programmed in Menu Item 8 of the menu. he cycle time for this operation is determined by the longer of solenoid ON time or the pump ON time. 29
30 Appendix A: Input/Output Description 4-Pin Connector Pacing (Pulse) Input / Opto-isolated Input Methods of riggering Series A9, B9, and C9 Pumps Reference: 4-Pin Cable (P/N 33796) Switch Pin 1 White Pin 2 Black NPN ransistor + - Pin 1 Pin 2 White Black PNP ransistor + - Pin 1 Pin 2 White Black Opto Isolator + - Pin 1 Pin 2 White Black Switch or transistor must be capable of switching 2 ma at 15 VDC. When in the Divide mode, the switch must close then open to trigger. Minimum time in low impedance state (i.e. switch closed) is 60 msec by default. Setup Menu Item 6 sets this value in multiples of 4 msec. Example: Default = 4 x 15 = 60 msec 30
31 Remote On/Off (Opto-isolated Input) Switching this line to ground starts the pump. Releasing this line, stops the pump. he SOP (Start/Stop) key will always override the SAR Remote Start/Stop. Reference: 4-Pin Cable (P/N 33796) Switch Closed = Start Pumping Switch Open = Stop Pumping Pin 4 Red Remote ON/OFF Pin 3 Green Ground Switch must be capable of switching 2 ma at +15 VDC. Minimum time in low impedance state (i.e. Switch closed) is approximately one (1) second. Low-Level Input (P/N and 29190E) Opening the float switch (i.e. breaking the line from ground) stops the pump and activates the alarm output. Float Switch Closed - Pump Running Float Switch Open - Pump Stopped - Alarm Activated Switch must be capable of switching 2 ma at +15 VDC. Minimum time in low impedance state (i.e. switch closed) is approximately 1 second. (For use with LMI Float Switches [P/N and E]. For further information, please refer to instructions included with the switches and to page 17 of this supplement.) 31
32 8-Pin Connector Analog 0-20 ma Input +0 to 20 ma White -0 to 20 ma Black +0 to 20 ma Violet - 0 to 20 ma Green his is reverse polarity protected with a 22 Ohm impedance, a resolution or 0.1 ma and an accuracy of +/- 0.2 ma typically. Flow Input (Opto-isolated Input) (See also Flow Monitoring on page 26) If an FM is used, use the Digi-Pulse phone jack. If some other device is used, this function can be accessed as shown below. Reference: 8-Pin Cable (P/N 33738) Pin 7 Brown Flow Input Pin 2 Black Ground Switch must closed for approximately three (3) msec and then open for the input to be accepted (i.e. switch to ground, then release). Switch must be capable of switching 2 ma at +15 VDC. 15V Output he +15V Output (pin 1 Red) is regulated and capable of delivering 30 ma current. 32
33 Alarm Output his is an opto-isolated open collector Darlington pair capable of switching 25 ma at +24 VDC to within 1V of ground typically. Reference: 8-Pin Cable (P/N 33738) Pin 6 Yellow GND Pin 2 Black he output pair turns ON when an alarm condition occurs (i.e. low level or missing pulse) and remains ON until the alarm condition is cleared. Application: Relay Switching +15V Pin 1 Red Alarm Output Pin 6 Yellow Load GND Pin 2 Black Computer Alarm Output his is an opto isolated, open collector output capable of switching 2 ma at +24 VDC to within 0.4V of ground typically. Reference: 8-Pin Cable (P/N 33738) Pin 8 Blue GND Pin 2 Black 33
34 his output tracks the alarm output (i.e. the conditions for activating and de-activating this output are the same as for the alarm output). his output may be used to directly switch small loads such as computer inputs and low current LEDs. It may also be used to initiate switching of larger loads if suitable buffer circuitry is provided. Application: Low Current LED Switching +15V Pin 1 Red 10K Ohms Pin 8 Blue GND Pin 2 Black *Low Current LED 1.0 ma = 10 mcd his is an opto-isolated, open collector output capable of switching 2 ma at +24 VDC to within 0.4V of ground typically. Pacing Output (Opto-isolated Output) Reference: 8-Pin Cable (P/N 33738) Pin 5 Orange GND Pin 2 Black he output transistor turns ON at the start of a stroke and remains ON for approximately 100 msec. 34
35 Appendix B: Summary of Error Messages E1 E2 IN IN FLOW E3 is caused by a Low-Level fault with a Low-Level Switch connected to the pump. he pump is stopped and the alarm outputs are activated. his operates in all Internal and External modes. he pump automatically restarts when the fault is cleared. indicates that the pump has lost prime (or the flow had reduced) when an FM200-9 is connected and Flow Monitoring is enabled. Again, the pump is stopped and output alarms activated. Restart the pump when the fault is cleared. E : is displayed in the External mode if the stroke rate E4 E5 E E FLOW P12 exceeds 100 SPM. he pump is NO stopped and NO alarm outputs are activated with this fault. o stop E3 flashing, clear the fault condition, then stop and restart the pump. is displayed in the External (Batch) mode in two situations: 1) If Batch Accumulate is disabled and a pulse signal is received while the pump is counting down. he pump is not stopped, and the alarms are not activated. o clear the E4 message, the pump must be stopped and restarted. 2) If Batch Accumulate is enabled and the cumulative batch value exceeds 999, E4 will be displayed. he E4 message can only be cleared if the pump is stopped and restarted. is displayed in the ma External mode if the ma input value exceeds 21.0 ma, whether the pump is running or stopped. Again, the alarms are NO activated. Once the ma signal goes below 21.0 ma, the E5 error message is cleared. 35
36 201 Ivyland Road Ivyland, PA EL: (215) FA: (215) LMI Milton Roy - All Rights Reserved Printed 36 in USA Specifications subject to change without notice. Digi-Pulse, LiquiComm are trademarks of Liquid Metronics, Inc.
INSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
REGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 FUSION CULTURE TABLE OF CONTENTS There s no point doing something if no one notices. We ve always believed the way to make things happen is by getting
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
Excellence through Versatility
Metering Pumps Excellence through Versatility Liquid Metronics Incorporated has been providing quality products and service to the water treatment industry worldwide for over 25 years. Leading the way
e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL
Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal
BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000
Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product
ALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL
Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL User s Guide Version 1.0 07/01/2009 Michael Stevens & Partners Ltd. has made
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.
BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER Installation, Operation, and Maintenance Instructions Manual No. M06-512 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY BROOKFIELD
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
e-ask electronic Access Security Keyless-entry
e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
How To Control A Car Alarm On A Car With A Remote Control System
MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock
Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.
Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current
1R / 4-BUTTON SERIES
Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Applied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
Car Alarm Series 2 B 2 Buttons
Car Alarm Series 2 B 2 Buttons G22 SE (External - Shock Sensor) Version 3 Software 67 Plus www.geniuscaralarm.com 21 CAR ALARM GENIUS Series 2B 2 Buttons - G22 Se (External Shock Sensor) Module controlled
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
PUSH BUTTON START INSTALLATION MANUAL
PUSH BUTTON START INSTALLATION MANUAL ALTHOUGH THIS PRODUCT HAS BEEN THOROUGHLY TESTED KPIERSON TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR ANY DAMAGE THAT MAY RESULT BY THE INSTALLATION OF THIS PRODUCT.
LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: [email protected] url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE
AL.1 AUTO SECURITY SYSTEM INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device
INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS
3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
G3 Series PROFIBUS DP Technical Manual
G3 Series PROFIBUS DP Technical 3835063 A - Table of Contents PAGE About PROFIBUS-DP...3 Overview...3 G3 PROFIBUS-DP Features...3 Cabling and Drop Line Lengths (as defined by PROFIBUS specification)...3
VEHICLE SECURITY SYSTEM G25/G20
VEHICLE SECURITY SYSTEM G25/G20 Limited Lifetime Warranty This vehicle security system is warranted to the original purchaser, to be free from defects in material and workmanship. The manufacturer will
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Automatic Telephone Dialer TD-101(W)
Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure
CAS MEDICAL SYSTEMS, INC. 510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure using the 2301Multi-Function Tester 44 East Industrial Road Branford, CT 06405 USA [email protected]
FAQ s on Siemens Magmeters
FAQ s on Siemens Magmeters 1. The cables for the coils and electrodes for the magmeters look the same. Does it matter which cable is used for coils and which one is used for the electrodes? Both cables
K9 Heat Alarm Owners Manual HA-1520
K9 Heat Alarm Owners Manual HA-1520 Your K9 Heat Alarm is a state of the art product designed and developed by ACEK9.COM a division of Radiotronics, Inc. It is a unique blend of positive features taken
INSTRUCTION MANUAL OVERVIEW. ---------- Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.
INSTRUCTION MANUAL ---------- Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series. OVERVIEW The digital Remote Meter displays system operating
PRO PLM Installation Instructions
PRO PLM Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Pocket DAB & FM Radio with Speaker
Pocket DAB & FM Radio with Speaker P MODEL: GDPRDAB USER MANUAL 1 Welcome 2 Your DAB Digital Radio 2.1 In The Box 2.2 Front View 2.3 Rear View 3 Quick Setup 3.1 Power On and Autoscan 3.2 Changing DAB Stations
BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT 194-722
HEWITT INDUSTRIES 5492 BOLSA AVE. HUNTINGTON BEACH, CA 92649 PH. (714) 891-9300 FAX. (714) 897-7632 WEBSITE: www.hewittindustries.com E-MAIL: [email protected] BACK PRESSURE MONITOR Operator Display
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
ADEMCO LYNXR-I Security Systems
K14117 3/06 Rev. A ADEMCO LYNXR-I Security Systems Quick Start Guide UL LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA)
Ordering Part Numbers:
TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)
Application: Heat quantity measurement This function calculates the heat quantity received and sent with liquid (water) in cooling and heating. Two 4-20mA inputs are available for temperature measurements.
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH
Mobile Satellite Solutions A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL SEARCH STOW Ver. 1 June 2012 WARNING Make all electrical and coax connections from the controller
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
EMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
NX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
VARIO PROX CARD READER INSTALLATION MANUAL
VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
CYMAQ Marking System AS200 + DS7050 N-14
CYMAQ Marking System AS200 + DS7050 N-14 Serial Number: 13716 CYMAQ www.cymaq.com INDEX 1. PRESENTATION AND GENERAL POINTS 1.1. General Points 1.2. Identification plate 2. MACHINE CHARACTERISTICS 2.1.
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS
BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS WG2 Dimensions: LxHXW: 26 x 14.5 x 29.5 cm INTERNAL Alarm Terminals EXTERNAL Alarm Terminals WG2 Control Unit WaterGuard
[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]
FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K Applicable Firmware Version: 1 ) 113-08501-100 or later (for U5) 2 ) 113-08502-030 or later
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
Model AM2. Installation Guide
Model AM2 Installation Guide NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may result
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification
Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Assembly 025A0215 600A0942 Rev. A May 14, 2012 025A0215 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
2004 Directed Electronics, Inc. Vista, CA N426V 07-04
350HV Installation Guide NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may result
magnetronic GmbH Kreuzhofstr. 10 81476 München Tel.: 089/7553670 Fax: 089/7556059 Email: [email protected] Battery control system DCC 6000
magnetronic GmbH Kreuzhofstr. 10 81476 München Tel.: 089/7553670 Fax: 089/7556059 Email: [email protected] Battery control system DCC 6000 Description and Operating Instructions Dear customer, You
PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator
3.635.5275.251 IM-P486-19 CH Issue 2 PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator Installation, Start-up and Operation Manual 1. Safety information 2. General product information 3.
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
Programming Logic controllers
Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0
SVC400P/SVC800P 4/8 Camera Live Tracking Vehicle DVR Installation Manual Version 1.0 1. MAIN FEATURES... 2 2. PRODUCT OVERVIEW... 2 3. DIMENSIONS... 4 4. PACKAGE CONTENTS... 5 5. MOUNTING AND ENVORNMENTAL
omega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box
omega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box 1 3/29/2010 Rev.0 DOC-OMEGABB9MAN 2 Introduction FMA1600-MDB Multi-Drop Box Operating Bulletin The FMA1600-MDB Multi-Drop Box
Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers
Technical Note Freedom/Fleet Power 512-0084-01-01 Rev 1 Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Overview This document is a guide for troubleshooting inverters, battery chargers,
Model SETR-50 and SETR-51 Trim Tab Control
Model SETR-50 and SETR-51 Trim Tab Control Pictured above is the SETR-50 with black switches on a gray background. The SETR-51 is identical except for the color, wherein it has black switches on a black
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
CONTROL SWITCHER User s Manual (Preliminary)
CONTROL SWITCHER User s Manual (Preliminary) www.voodoolab.com Copyright 2010 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. Voodoo Lab, Control Switcher,
Sierra S-Series Smart Interface Software User Manual
Sierra S-Series Smart Interface Software User Manual Part Number IM-SIP 08/99 Revision B 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com
User and installation manual
User and installation manual aquaero 5 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of April 2011 ENGLISH: PAGE 1 DEUTSCH: SEITE 13
OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder
P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It
DOSISYS. Hands Free Reader LDM 210 - LDM 220. User Manual 127356A
DOSISYS LDM 210 - LDM 220 Hands Free Reader User Manual 127356A Publication, translation and reproduction total or partial of this document is strictly forbidden without authorization MGP Instruments
G-100/200 Operation & Installation
G-100/200 Operation & Installation 2 Contents 7 Installation 15 Getting Started 16 GPS Mode Setup 18 Wheel Sensor Mode Setup 20 Fuel Calibration 23 Basic Operation 24 Telemetery Screen 27 Entering a Distance