Operating Instructions
|
|
|
- Melinda Reed
- 9 years ago
- Views:
Transcription
1 Operating Instructions FiveEasyPlus ph meter FEP20
2
3 Contents Contents 1. Introduction 3 2. Safety measures 3 3. Installation Installing the electrode arm (optional for FEP20) 4 4. Operating the FiveEasyPlus Display and key controls Calibration Buffer groups Selecting a predefined buffer group Performing a 1- or 2-point calibration Performing a 3-point calibration Sample measurement Performing a ph measurement Performing a mv / Redox measurement Temperature measurement Manual temperature compensation Using the memory Storing a reading Recalling from memory Clearing the memory Print-out Connection and configuration Print-out following measurement Print-out following calibration Printing from memory Self-diagnosis Error message Maintenance Meter maintenance Electrode maintenance Disposal Accessories Specifications Appendix Buffer tables Error Limits 16 METTLER TOLEDO FiveEasyPlus 1
4 2 METTLER TOLEDO FiveEasyPlus
5 1. Introduction Introduction / Safety measures Thank you for purchasing this high quality METTLER TOLEDO meter. Ease of use, reliable results and ergonomic design these are our goals for products. The Five meters have an excellent price/performance ratio and many useful accessories (e.g. electrode clip and wrist strap for the portable meter) are already included in the standard delivery of the instruments. Other accessories such as electrodes, solutions, an electrode arm for the bench meter or a carry bag for the portable meter are of course also available from METTLER TOLEDO. You will find much helpful functionality in these meters. A few of many exiting features are: - Automatic endpoint format which freezes the measurement automatically when the value is stable; - four predefined buffer groups to select from; - automatic buffer recognition which allows you to calibrate with your buffers in any order; 2. Safety measures Measures for your protection - Never work in an environment subject to explosion hazards! The housing of the instrument is not gas tight (explosion hazard due to spark formation, corrosion caused by the ingress of gases). - When using chemicals and solvents, comply with the instructions of the producer and the general lab safety rules! Measures for operational safety - Do not unscrew the two halves of the housing! - Dry off any liquid spills immediately! The instrument is not watertight! - Exclude the following environmental influences: powerful vibrations, direct sunlight, atmospheric humidity greater than 80%, corrosive gases present, temperatures below 5 C and above 40 C, powerful electric or magnetic fields! METTLER TOLEDO FiveEasyPlus 3
6 Installation 3. Installation Carefully unpack the meter. Keep the calibration certificate in a safe place. Insert the right adapter clip into the power adapter slot: PUSH 3.1 Installing the electrode arm (optional for FEP20) The electrode arm can be fastened to FiveEasyPlus on the left or the right side. 1. Remove the electrode stand rubber cover on that side of the bench meter where you prefer the stand. Keep the cover in a safe place; 2. Insert the electrode stand firmly into the opening as shown; 3. Fix the opening of the arm upon the stand from above, adjust it to a moderate height. 4 METTLER TOLEDO FiveEasyPlus
7 Operating the ph meter 4. Operating the FiveEasyPlus 4.1 Display and key controls 1 Electrode condition (For electrode maintenance see section 5.2) Slope: % Slope: % Slope: % and offset: ± (0-15) mv or offset: ± (15-35) mv or offset: ± (>35) mv Electrode is in Electrode needs Electrode is defective good condition cleaning 2 Calibration icon - calibration in progress 3 Measurement icon - measurement or calibration is running 4 Setup icon - instrument is in the setup mode 5 ph/mv reading or slope in calibration process 6 Auto / Manual temperature compensation (see section 4.4) 7 Endpoint stability / Auto endpoint 8 Temperature during measurement or offset in calibration process 9 Calibration point / Buffer group number / Memory number / Error index METTLER TOLEDO FiveEasyPlus 5
8 Operating the ph meter Keys for FEP20 Press & release Press & hold for 3 seconds - Start or endpoint measurement - Confirm setting, store entered value - Turn auto endpoint on / off, - Start calibration - Review the latest calibration data - Meter on - Back to measurement screen - Meter off - Store current reading to memory - Increase value during setting - Scroll up through the memory - Switch between ph and mv measuring modes - Decrease value during setting - Scroll down through the memory - Start self-diagnosis - Recall stored data - Print current data set of stored data - Enter Setup mode 4.2 Calibration Buffer groups The FiveEasyPlus ph meter allow you to perform 1, 2- or 3- point calibrations. After selecting your calibration buffer group from one of the three predefined buffer groups in the meter, the buffers are automatically recognized and displayed during calibration (auto buffer recognition). The four predefined groups are: B (at 25 C) B (at 25 C) B (at 25 C) B (at 25 C) Tables (B1...B4) for automatic temperature compensation are programmed in the meter for each buffer group (see also Appendix) Selecting a predefined buffer group Press and hold the key until the setup icon appears on the display and the MTC temperature blinks. Press Read to ignore the current temperature unit blinks press to ignore again. When the current buffer group blinks, the buffers belonging to this buffer group appear alternating on the display. Use or to select another buffer group and press to confirm your selection. The meter will exit automatically to the measurement screen. 6 METTLER TOLEDO FiveEasyPlus
9 4.2.3 Performing a 1- or 2-point calibration Operating the ph meter Place the electrode in a calibration buffer and press. The calibration icon and the measurement icon appear on the display. The meter endpoints according to the preselected endpoint mode after the signal has stabilized or after pressing. The relevant buffer value is displayed and stored; the measurement icon disappears from the display. To perform a 2-point calibration rinse the electrode with deionized water, place the electrode in the next calibration buffer and repeat the step above. To finish the calibration and return to the sample measurement, press. The offset value and the slope are then shown on the display for 3 seconds. To reject the calibration, press before the meter returns automatically after 3 seconds to the measurement screen. Note: With the 1-point calibration only the offset is adjusted. If the sensor was previously calibrated with muti-point calibration the previously stored slope will remain. Otherwise theoretical slope ( mv / ph) will be used Performing a 3-point calibration Step 1: Perform the first and second calibration steps as described above in "Performing a 1- or 2-point calibration". Step 2: Rinse the electrode with deionized water. Step 3: Place the electrode in the next calibration buffer and press. The measurement icon appears. The meter endpoints according to the preselected endpoint mode after the signal has stabilized or after pressing. The relevant buffer value is displayed and stored; the measurement icon disappears from the display. The offset value and the slope are then shown on the display for 3 seconds. To reject the calibration, press before the meter returns automatically after 3 seconds to the measurement screen. Note: The use of a temperature sensor or an electrode with a built-in temperature sensor is recommended. If you use the MTC mode, you should enter the correct temperature value and keep all buffer and sample solutions at the set temperature. To ensure the most accurate ph readings, you should perform a calibration once a day. 4.3 Sample measurement Performing a ph measurement Place the electrode in the sample and press to start the measurement: the measurement icon appears on the display and the decimal point blinks. The display shows the ph value of the sample. The automatic endpoint is the default setting of the meter. When the signal has stabilized, the display freezes automatically, appears and the measurement icon disappears. By pressing and holding, you can switch between the auto and manual endpoint modes. To manually endpoint a measurement, press : the display freezes and appears. Stability criterion for ph and mv measurement The signal of the sensor input may not change by more than 0.15 mv in 6 seconds. METTLER TOLEDO FiveEasyPlus 7
10 Operating the ph meter Performing a mv / Redox measurement To switch to mv mode, press. To perform a mv measurement, follow the same procedure as for ph measurement. (For Redox measurements, connect a Redox sensor first.) 4.4 Temperature measurement For better accuracy, we recommend the use of either a built-in or a separate temperature probe. If a temperature probe is used, and the sample temperature are displayed. Note: The meter accepts an NTC 30 kω temperature sensor Manual temperature compensation If the meter does not detect a temperature probe, it automatically switches to the manual temperature compensation mode and MTC appears. To set the MTC temperature and the temperature unit, press and hold until the setup icon appears on the display and the MTC temperature blinks. Use or to increase or decrease the value to the temperature of your sample. Press to confirm the setting. The meter proceeds automatically to the temperature unit setting. Press to leave the setup without changing the temperature unit or use or to select between C (Celsius) or F (Fahrenheit). Press to confirm the setting. The meter proceeds automatically to the calibration setting; press Exit to leave to setup. The default setting is 25 C. 4.5 Using the memory Storing a reading FiveEasyPlus FEP20 ph meter can store up to 99 endpointed results. Press when the measurement has endpointed. indicates that one result has been stored. If you press when is displayed, indicates the memory is full. To store further data you will have to clear the memory (see below) Recalling from memory Press and hold RCL to recall the stored values from memory when the current measurement has endpointed. Press or to scroll through the stored results. to indicates which result is being displayed. Press to exit Clearing the memory Continue pressing or to scroll through the stored results until appears. Then press Read, CLr blinks. Press Read again to confirm the deletion or press to return to the measurement mode without deleting the data. 8 METTLER TOLEDO FiveEasyPlus
11 Operating the ph meter 4.6 Print-out Connection and configuration A printer can be connected to the RS-232 interface of FEP20. The use of the RS-P25, RS-P26 or RS- P28 printer is recommended, because they recognize the FEP20 and adjust the correct parameters automatically. In case a different printer is used, the following parameters need to be set: Baud rate: Data bit: Parity bit: Stop bit: 1200 bps 8 bit None 1 bit Print-out following measurement If a printer is connected to the FEP20, a print-out is automatically generated after each endpointed measurement or calibration. The format for the print-out following a ph measurement is: EP, Value, Unit, Temp. AE 4.01pH 25.0ºC MTC The details for the second line are: AE 4.01pH 25.0ºC MTC ---- ATC or MTC Temperature value ph value AE for Auto-End-Point, ME for Manual-End-Point The format for the print-out following a mv measurement is: EP, Value, Unit, Temp. AE 930mV 25.0ºC MTC The print-out in case of an error message is: EP, Value, Unit, Temp. Error Print-out following calibration The print-out for a 2-point calibration is: Buffer1 4.01pH mv1 178mV Temp ºC Buffer2 7.00pH mv2-0mv Temp ºC Slope 101% Offset -0mV ATC/MTC MTC METTLER TOLEDO FiveEasyPlus 9
12 Operating the ph meter The print-out for a 3-point calibration is: Buffer1 4.01pH mv1 178mV Temp ºC Buffer2 7.00pH mv2-0mv Temp ºC Buffer3 9.21pH mv3-130mv Temp ºC Slope 100% Offset -0mV ATC/MTC ATC Printing from memory When scrolling through the memory (see 4.6.2) you can print the entry that is currently viewed by pressing and holding the key for 2 s. The printout format is following: Recall 01: EP, Value, Unit, Temp. ME 4.01pH 35.6ºC ATC 4.7 Self-diagnosis Press and hold and simultaneously until the meter displays the full screen. Each icon blinks one after the other. This way you may check whether all icons are correctly shown. The next step is to check that the keys are functioning correctly. This requires user interaction. When blinks, five icons are displayed. Press the five keys in any order. Each time you press a key an icon disappears from the screen, continue to press the other keys until all the icons have disappeared. When the self-diagnosis has been completed successfully, error message appears (see section 4.8). appears. If self-diagnosis fails, Note: You have to finish pressing all five keys within two minutes, otherwise have to repeat the procedure. appears and you will 10 METTLER TOLEDO FiveEasyPlus
13 Operating the ph meter 4.8 Error message Error 0 Memory access error Reset to factory settings Error 1 Self-diagnosis failed Repeat the self-diagnosis procedure and make sure that you finish pressing all five keys within two minutes. Error 2 Measured values out of range Make sure that the electrode wetting cap has been removed and the electrode is properly connected and placed in the sample solution. If no electrode is connected, put the shorting plug in the socket. Error 3 Measured buffer temperature out of range ( C) Keep the buffer temperature within the range for calibration Error 4 Offset out of range Make sure you have the correct buffer and that it is fresh. Clean or replace the electrode. Error 5 Slope out of range Make sure you have the correct buffer and that it is fresh. Clean or replace the electrode. Error 6 Error 9 Meter cannot recognize the buffer The current data set has already been stored once Make sure you have the correct buffer and that it is fresh. Check that the buffer has not been used more than once during the calibration. A measurement can only be stored once. Perform a new measurement to store a new data set. METTLER TOLEDO FiveEasyPlus 11
14 Maintenance 5. Maintenance 5.1 Meter maintenance Never unscrew the two halves of the housing! The Five series instruments do not require any maintenance other than occasional wipe with a damp cloth. The housing is made of acrylonitrile butadiene styrene/polycarbonate (ABS/PC). This material is attacked by some organic solvents, such as toluene, xylene and methyl ethyl ketone (MEK). Any spillage should be immediately wiped off. 5.2 Electrode maintenance Make sure the electrode is filled with electrolyte solution if applicable. For maximum accuracy, any filling solution that may have "crept" and encrusted the outside of the electrode should be removed with deionized water. Always store the electrode according to the manufacturer s instructions and do not allow it to dry out. If the electrode slope falls rapidly, or if the response becomes sluggish, the following procedures may help. Try one of the following, depending the samples usually measured. 1. For fat or oil build-up, degrease the membrane with cotton wool soaked in either acetone or a soap solution. 2. If the sensor membrane has dried out, soak the tip of the electrode in 0.1 M HCl overnight. 3. If a protein build-up has occurred in the diaphragm, remove deposits by soaking the electrode in an HCl /pepsin solution ( ). 4. If a silver sulfide contamination has occurred, remove deposits by soaking the electrode in a solution of thiourea ( ). After treatment a new calibration should be performed. Note: Cleaning and filling solutions should be handled with the same care as that given to toxic or corrosive substances. 5.3 Disposal In conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environment protection. 12 METTLER TOLEDO FiveEasyPlus
15 Accessories 6. Accessories Item Order No. Power supply Electrode arm Rubber covers (for electrode arm hole) Shorting plug BNC ph 4.01 buffer sachets, 30 x 20 ml ph 4.01 buffer solution, 6 x 250 ml ph 7.00 buffer sachets, 30 x 20 ml ph 7.00 buffer solution, 6 x 250 ml ph 9.21 buffer sachets, 30 x 20 ml ph 9.21 buffer solution, 6 x 250 ml ph buffer sachets, 30 x 20 ml ph buffer solution, 6 x 250 ml Rainbow (box of each, 10 x 20 ml, 4.01/7.00/9.21) Rainbow (box of each, 10 x 20 ml, 4.01/7.00/10.01) LE407, combination ph sensor, plastic, gel electrolyte LE408, combination ph sensor, plastic, liquid electrolyte, refillable LE409, combination ph sensor, glass, refillable LE420, special ph sensor with PTFE junction, refillable LE427, spear tip design, low maintenance LE438, 3-in-1 ph sensor, plastic, ATC LE501, Redox-sensor, glass LE510, Redox-sensor, plastic ATC probe, temperature sensor HCl/Pepsin solution(removes protein contamination), 1 x 250 ml Thiourea solution (remove silver sulfide contamination), 1 x 250 ml Reactivation solution for ph electrodes, 1 x 25 ml METTLER TOLEDO FiveEasyPlus 13
16 Specifications 7. Specifications FiveEasyPlus ph meter FEP20 Measurement range ph mv 0 C to 100 C Resolution 0.01 ph 1 mv 0.1 C Limits of error ± 0.01 ph ± 1 mv ± 0.5 C ph calibration Up to 3 points Isopotential point ph 7.00 Calibration buffer 4 predefined groups Number of memory 99 Power requirements 9 V DC, 0.4 W ± 10% For use with CSA certified (or equivalent approved) power source, which must have a limited circuit output. Size/weight 200 x 175 x 52 mm / 0.6 kg Display Liquid crystal ph input BNC, impedance > 10e+12 Ω T input Cinch, NTC 30 kω Reference input 2mm banana socket IP rating For indoor use only Ambient conditions Temperature: C Relative humidity: 5 %...80 % (non-condensing) Height: up to 2000 m Installation category: II Pollution degree: 2 Materials Housing: ABS/PC reinforced Window: Membrane Keypad: Membrane 14 METTLER TOLEDO FiveEasyPlus
17 Appendix 8. Appendix 8.1 Buffer tables FiveEasyPlus ph meter automatically corrects for the temperature dependence of the buffer ph using the values given in the tables. Buffer group 1 (ref.25 C) MT US Buffer group 2 (ref.25 C) MT Europe Buffer group 3 (ref. 25 C) JJG 119 Chinese Buffer group 4 (ref. 25 C) JIS Z 8802 Japanese METTLER TOLEDO FiveEasyPlus 15
18 Appendix 8.2 Error Limits Message Description Range not accepted Err 2 Measured values out of range ph: < 0.00 or > mv: < or > 1999 Err 3 Buffer temperature out of range T[ C] < 5 or > 40 Err 4 Offset out of range Eref1-Eb > 60mV Err 5 Slope out of range Eref1-Eb > 60mV Err 6 Wrong buffer ΔEref1 < 10mV 16 METTLER TOLEDO FiveEasyPlus
19
20 Quality certificate. Development, production and testing according to ISO9001. Environmental management system according to ISO Worldwide service. Our extensive service network is among the best in the world and ensures maximum availability and service life of your product. On the Internet. You will quickly find lots of essential information about our products, our services, and our company at * * Subject to technical changes and to the availability of the accessories supplied with the instruments. Mettler-Toledo AG A Printed in China 1111 Mettler-Toledo AG, Analytical, Sonnenbergstrasse 74, CH-8603 Schwerzenbach, Tel , Fax , Internet:
Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso
Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso SevenEasy Conductivity Italiano Español Français Deutsch English Contents Contents Page 1. Introduction...
SenTix 950 SenTix 980
SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009 SenTix The latest version of the present operating manual can be found on the
MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL
MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL 430 350/REV A/10-03 MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL CONTENTS Introduction 1 Specification 2 Installation 3 Displays 3-4
ph 200 ph-/redox-/temperature Meter Operating instructions
ph 200 ph-/redox-/temperature Meter Operating instructions 2 Table of Contents Page 1. Scope of delivery...4 2. System description...4 3. Connections...5 4. Display...7 5. Keypad...7 6. Start up...8 7.
UltraBasic Benchtop ph Meter Operation Manual
UltraBasic Benchtop Meter Operation Manual UB-5 Denver Instrument Measuring 4 4 7 10 Meter 22.2 C 4.06 UltraBasic 902388.1 Rev. A UltraBasic Meter Quick Reference 1. Connect a AC adapter to the power connection.
Nitrogen, Ammonia. Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table
Nitrogen, Ammonia DOC316.53.01234 Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N Scope and application: For wastewater 2. Ammonia ISE 1 Adapted from the Standard Methods for the Examination
Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE
Sodium DOC316.53.01240 Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Scope and application: For drinking water and process water. Test preparation Instrument-specific information This procedure
USEPA Electrode Method Method 8156
ph DOC316.53.01245 USEPA Electrode Method Method 8156 Scope and application: For drinking water 1, wastewater 2 and process water. 1 Based on Standard Method 4500-H+B, ASTM Method D1293-95 and USEPA Method
Compact ph Measuring Instruments
testo 205, 206, 230 Compact ph Measuring Instruments With innovative probe engineering ph C The new ph measuring instruments with innovative probe engineering Measurement of the ph value plays an important
Model 4510 Conductivity/TDS Meter Operating Manual
Model 4510 Conductivity/TDS Meter Operating Manual SAFETY Please read this information carefully prior to installing or using this equipment. 1. The unit described in this manual is designed to be operated
ExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
Resolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or
Instruction Manual Temp 4/5/6 Temperature Meter Series
Instruction Manual Temp 4/5/6 Temperature Meter Series 68X243607 Technology Made Easy... Rev. 2 01/03-1 - Preface This instruction manual serves to explain the use of the Temp 4/5/6 temperature meter.
OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:
BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending
User Guide ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens Patent Pending Getting Started Remove the cap from the bottom of the ExStik TM to expose the electrode bulb and reference
Portable Waterproof ph/dissolved Oxygen Meter
Notes Write down the name and information of your OKTON distributor here. OPERTING INSTRUTIONS OKTON 35632-Series Portable Waterproof /Dissolved Oxygen Meter WTERPROOF REDY MES % T /Dissolved Oxygen/ /
Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor
Oxygen, Dissolved DOC316.53.01241 Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor Scope and application: For water, wastewater and process
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
ph Measurement and Control
ph Measurement and Control Tech Tip #14 1997 I. The Need for ph II. ph System Requirements III. ph Electrode Conditioning Procedures IV. How the electrode works V. Identifying the Electrode Components
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of
Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of the blood 7 Procedure to test glucose 7 Procedure to
Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01
Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery
Dissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
ph-meter 1140 and ph-meter 1140-X Instruction manual
ph-meter 1140 and ph-meter 1140-X Instruction manual Mettler-Toledo GmbH Process, Postfach, 8902 Urdorf, Switzerland Phone: +41 (1) 736 22 11 Telefax: +41 (1) 736 26 36 Warranty Defects occurring within
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
Care and use guide. Contents. page
Care and use guide Contents page Features Bluelab Combo Meter Introduction Preparing for use Calibration Changing nutrient and temperature display units 6 Measuring hydroponic elements 7 Battery replacement
Temperature Humidity Meter
971 Temperature Humidity Meter Users Manual PN 2441047 September 2005 Rev.1, 5/06 2005-2006 Fluke Corporation, All rights reserved. Printed in Taiwan All product names are trademarks of their respective
RS DIGITAL THERMOMETER
RS DIGITAL THERMOMETER 1319A INSTRUCTION MANUAL C F MX MN AVG TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION... 1 2. SPECIFICATIONS... 1 3. NAME OF PARTS AND POSITIONS... 3 4. OPERATION INSTRUCTIONS... 5
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
Instruction Manual DO 110. Hand-held Dissolved Oxygen Meter with RS 232C. 68X361305 Rev. 0-11/05. Technology Made Easy...
Instruction Manual DO 110 Hand-held Dissolved Oxygen Meter with RS 232C Technology Made Easy... 68X361305 Rev. 0-11/05 Preface This manual serves to explain the use of the hand-held series meters. The
Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer
User Manual Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer MODEL 42515 Introduction Congratulations on your purchase of the Model 42515 IR Thermometer. The Model 42515 IR thermometer
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
Milwaukee USER MANUAL
Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the
Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements
Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.
Instruction Sheet PN 51A-397/rev.F January 2011 Model 397 ph Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS MODEL 397 PERFORMANCE
USER GUIDE. LED Light Meter. Model LT45
USER GUIDE LED Light Meter Model LT45 Introduction Congratulations on your purchase of the Extech LT45 LED Light Meter that measures light from LED lamps in addition to fluorescent, metal halide, high
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
Operating manual. ph 3110. ph meter. ba75791e02 11/2008
AR Operating manual ph 3110 ph 6 9 9 2 2 4 8 C TP ph meter ph 3110 Accuracy when going to press The use of advanced technology and the high quality standard of our instruments are the result of a continuous
User's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN
User's Guide Digital Psychrometer Model RH390 MAX MIN F C WBT Dew Point Introduction Congratulations on your purchase of the Extech RH390 Digital Psychrometer. This device measures Humidity, Air Temperature,
Thermocouple Thermometer Models
Technology Made Easy... Thermocouple Thermometer Models 60010-00 (Type J) 60010-10 (Type K) 60010-20 (Type T) 68X309905 Rev 1 04/04 TABLE OF CONTENTS 1. INTRODUCTION 4 2. SAFETY PRECAUTIONS 6 3. SPECIFICATIONS
AIRMoN, ph and Conductivity Field Measurement
AIRMoN, ph and Conductivity Field Measurement Items needed: Sample to be measured (sample volume 50 ml) Field Observer Form (FOF) for the sample to be measured conductance cell ph vials, 4 conductivity
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
User Guide. Temperature and Humidity Datalogger. Model 42280
User Guide Temperature and Humidity Datalogger Model 42280 Introduction Congratulations on your purchase of the Extech 42280 Thermometer and Relative Humidity Datalogger. The 42280 is a wall-mount, tripod
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
Care and use guide. Contents. a handy solution made easy. www.getbluelab.com. page
Care and use guide Contents page Features Quick guide Before use To operate Important - ph pen probe care 4 Cleaning 5 Battery replacement 5 Hydration 6 Calibration 6 Error messages 7 Troubleshooting guide
Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph 7310. ph meter
Operating manual ph 7310 ph 7310P Printermodul ph 7310P ph 7310 ph meter ba75929e02 10/2011 ph 7310 Copyright Weilheim 2011, WTW GmbH Reproduction in whole - or even in part - is prohibited without the
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS
MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL
MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL 970 350/REV A/10-03 MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL CONTENTS Introduction 1 Specification 1 Installation 2 Displays 2-3 Controls 4 Preparation
PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN 2011. In Use Date: 2/1/2011 Discontinued Date:
PROCEDURE COVERSHEET Procedure Title: ph (Urine, Body Fluid, Platelet Samples) Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN 2011 Laboratory Director: TED KURTZ, MD (PARNASSUS & CHINA
Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen
Laboratory Electrochemistry Products ph Conductivity Dissolved Oxygen Spoilt for choice Small footprint Adjustable viewing angle Wall mountable New style electrode holder Contents page Overview................................3
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
62 Max/62 Max + Infrared Thermometer
Infrared Thermometer Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measurement of the infrared energy radiated from the target
Care and use guide. Contents. a handy solution made easy. www.getbluelab.com. page
Care and use guide Contents page Features 2 Quick guide 2 To operate 3 Cleaning 4 Battery replacement 4 Calibration 5 Error messages 5 Troubleshooting guide 6 Technical specifications 6 Information about
Instruction Manual HI 96801 Refractometer for Sucrose Measurements
Instruction Manual HI 96801 Refractometer for Sucrose Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information
SevenGo Duo. Quick and Reliable Measurements for Results at your Fingertips. SevenGo Duo Portables SevenGo Duo SevenGo Duo pro
SevenGo Duo SevenGo Duo Portables SevenGo Duo SevenGo Duo pro ph / ORP Conductivity Ion Concentration Dissolved Oxygen Quick and Reliable Measurements for Results at your Fingertips Introduction The SevenGo
NI USB-5681 RF Power Meter Specifications
NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Model UT201/202: OPERATING MANUAL. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness
Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene
Weighing terminals The stainless steel weighing terminals of the 4 Series: IND429, IND439 and IND449 The optimal solution for demanding applications in the food, pharmaceutical and chemical industries.
Thermistor Thermometer MODEL NO. 93210-00
Thermistor Thermometer MODEL NO. 93210-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail:
User s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
digital fever alert ear thermometer suitable from birth instruction manual
digital fever alert ear thermometer suitable from birth instruction manual digital fever alert ear thermometer instruction manual Please read these instructions carefully before using the thermometer and
Integrating Sound Level Meter and Datalogger
USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,
REDOX AND REFERENCE ELECTRODE USER MANUAL
REDOX AND REFERENCE ELECTRODE USER MANUAL 3 Redox and reference electrode manual Copyright 2012 Unisense A/S Version October 2012 REDOX AND REFERENCE ELECTRODE MANUAL UNISENSE A/S TABLE OF CONTENTS WARRANTY
Refer to page 6 to page 19 for detailed instructions.
CODE:GZ0000297065 Refer to page 6 to page 19 for detailed instructions. Preface This manual describes the operation of the COMPACT CONDUCTIVITY METER, B-771. Be sure to read this manual before using the
Instruction Manual HI 9146. Portable Waterproof Microprocessor Dissolved Oxygen Meter
Instruction Manual HI 9146 Portable Waterproof Microprocessor Dissolved Oxygen Meter w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction
HIH-4000 Series Humidity Sensors
HIH-4000 Series Humidity Sensors DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input to a controller or
ph and Acidity in Tomato Sauce
ph and Acidity in Tomato Sauce DOC316.52.93100 Endpoint potentiometric titration Scope and application: Tomato sauce 1. Introduction This working procedure refers to the determination of titratable acidity
Body Fat Scale Instructions for use
Body Fat Scale Instructions for use The scale is specially designed to test your body weight, body fat, hydration, muscle and bone percentages and to help you keep a close eye on the daily changes of your
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Model UT713 OPERATING MANUAL
Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC
User Manual. Thermo Scientific Orion VERSA STAR
User Manual Thermo Scientific Orion VERSA STAR Advanced Electrochemistry Benchtop Meter 68X006501 Revision A April 2014 Contents Chapter 1 Meter Introduction... 6 Meter Overview... 6 Packing List... 7
DISSOLVED OXYGEN PROBE
51970-88 DISSOLVED OXYGEN PROBE Introduction This instruction sheet provides information on the Hach Dissolved Oxygen Probe for use with the sension 6 Dissolved Oxygen Meter. The Dissolved Oxygen Probe
Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...
Instruction Manual ph 5+ ph/ C ph 6+ ph/ C/mV Ion 6+ ph/ C/mV/Ion Technology Made Easy... 68X243633 Rev 1-1 3/2011 Part of Thermo Fisher Scientific Preface This instruction manual serves to explain the
OxyGuard. Dissolved Oxygen Probe
OxyGuard Dissolved Oxygen Probe Standard type USER MANUAL D02 Standard Probe manual gb 0903 CONTENTS 1. DESCRIPTION 1.1 The OxyGuard Probe... 1 1.3 Which kind of transmitter can be used with the OxyGuard
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
INSTRUCTION MANUAL. Handy Polaris
INSTRUCTION MANUAL Handy Polaris **This page is left blank** Table of Contents 1 General...4 2 Setup...5 2.1 Calibrate...5 2.2 Set Salinity...5 2.3 User Interface...5 2.3.1 Language...5 2.3.2 Temperature
BW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
CappController Pipette Controller. Operation Manual Version: 1.2. www.capp.dk
CappController Pipette Controller Operation Manual Version: 1.2 www.capp.dk skal vises her. Table of Content 1. Safety Precautions... 1 2. General Description... 2 3. Getting Started... 4 3.1. Recharging
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Operating manual. ph 7110. ph meter
Operating manual ph 7110 ph meter ba75925e02 12/2011 ph 7110 Copyright Weilheim 2011, WTW GmbH Reproduction in whole - or even in part - is prohibited without the express written permission of WTW GmbH,
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
Nokia Bluetooth Headset BH-102. Issue 1
Nokia Bluetooth Headset BH-102 1 2 3 4 45 46 7 8 10 119 Issue 1 DECLARATION OF CONFORMITY Hereby, NOKIA CORPORATION declares that this HS-107W product is in compliance with the essential requirements and
Bluelab Soil ph Meter Instruction Manual
Instruction Manual www.getbluelab.com Table of Contents 1.0 Information about measuring the ph of soils/media. 2 2.0 Introduction to Bluelab Soil ph Meter 4 3.0 Preparing the Bluelab Soil ph Meter for
Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.
Instructions: Part I. Charge the Power Bank Method 1 Charge the Power Bank via Computer USB Terminal. Connect the provided USB power cable to the micro- USB plug connector tip (the tip marked "M10"). Step
GSM Temperature Alerter. User Manual. Manual version 1.0
GSM Temperature Alerter User Manual Manual version 1.0 This brochure suits for 19-0415 model. 19-0415 GSM Temperature Alerter USER MANUAL 19-0415 GSM Temperature Alerter Thank you for purchasing the 19-0415.
Pro1030 USER MANUAL. English
Pro1030 USER MANUAL English Contents Warranty...i Introduction...1 Item #605182 Rev A, January 2013 For the latest version of this manual, visit ysi.com 2013 YSI Incorporated. The YSI logo is a registered
Technical Note Series
Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment
ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0
ACID-BASE TITRATION LAB PH 2.PALM INTRODUCTION Acids and bases represent a major class of chemical substances. We encounter them every day as we eat, clean our homes and ourselves, and perform many other
ph 300 and 310 Portable Waterproof ph/mv/ C Meter
Notes Write down the name and information of your OKTON distributor here. OPERTING INSTRUTIONS OKTON 35618-Series 300 and 310 Portable Waterproof /mv/ Meter REDY MES WTERPROOF T /mv/ Data Meter 300 Series
Action Camcorder Rollei Youngstar USER MANUAL
Action Camcorder Rollei Youngstar USER MANUAL Mounting Accessories 1 Functions This user's manual has referred to the latest information we had when this user s manual was made. The screen display and