Spec Setter Safety Switches

Similar documents
Safety Switches. Section 4.

Heavy Duty Safety Switches

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Square D Safety Switches

Section 4. Safety Switches.

Cutler-Hammer January 1999

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

GHN424NW HHN426N HUN361AW

Scepter PVC Molded Junction Boxes

Plugs and Receptacles

MCC Ratings. Voltage Rating

Bolted contact switches. Pringle switches

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

ASCO SERIES 185 Power Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

EDS / EFS Series Control Stations

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Rugged & Reliable Power Connections

1 SAFETY & DISCONNECT SWITCHES

JIC CONTINUOUS HINGE BOXES

Secondary Unit Substations

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Scepter PVC Molded Junction Boxes

Application Guide Selection of Type Enclosures

Electrical Service Guidelines

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Power Outlet Panels. Product Guide

Type 1, 3, & 3R Enclosures

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

NEMA Enclosure Types

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

EDS / EFS Series Control Stations

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

8146/5 Series Breaker Panelboards

Cable/Conduit Conversion

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

SPEEDFAX TM 2011 Disconnect Switches Contents

Advantages of a Company Switch vs. a Safety Switch Receptacle Combination:

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

RAY-MAX Integrated Solar Power Strip

Selection and Application Guide Type VBII. safety

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Generator DoCKInG StatIonS

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Mini Power-Zone Unit Substation

Distribution Dry Type Transformers

Temporary Power Outlet Panels

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

GE Power Controls. MiniFORM Switchboards

Explosion-Proof Electric Unit Heaters

Mechanical Pushbutton Locks Keyless Convenience

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

GUE, GUB Junction Boxes

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Table of Contents. IV. Interior Doors. 1. Product Training 2. Bilco Quote/Order Checklist

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Single Phase Soft Starter

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

FLB Series Circuit Breakers and Enclosures

Electrical Code Regulation

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Catalog January. Heavy industrial power applications Motor contactors and starters

TRANSFORMER DICTIONARY

This section applies to the design and installation of transformers.

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Solar Power Solutions

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

LED High Bay Light 100W

Distribution Boards & Consumer Units

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

Diesel Engine Driven Generators Page 1 of 6

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014)

Equipment. Metering. Metering Equipment 1. Contents

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

Transcription:

GE Electrical Distribution Spec Setter Safety Switches We help you get the job done right! imagination at work

General Electric s Spec Setter safety switches are available for all your disconnect needs, no matter what the application. GE offers a wide variety of general duty switches for residential and light commercial purposes, while our extensive line of heavy duty switches is best suited for commercial and industrial applications. For the toughest industrial environments like cement foundries, steel mills and processing plants mill duty switches are available. We also offer a variety of double throw switches for emergency generators. No matter what the application, we ve got you covered with a rugged, reliable and easy-to-install Spec Setter safety switch. When it comes to getting the job done right, you can count on GE!

GE Safety Switches at a Glance NEMA Type Type 0 A 60 A 00 A 00 A 00 A 600 A 800 A 00 A Enclosure General Duty Pole (Non-Fusible) 0Vac Heavy Duty Pole (Fusible & Non-Fusible) 600Vdc Pole (Fusible & Non-Fusible) 600Vac Pole (Non-Fusible) 0Vac & 600Vac Double-Throw Pole (Fusible) 0Vac Pole (Fusible) 600Vac General Duty Pole (Non-Fusible) 0Vac Heavy Duty Pole (Fusible & Non-Fusible) 600Vdc Pole (Fusible) 600Vac Pole (Non-Fusible) 600Vac R Pole (Fusible) 600Vac Pole (Non-Fusible) Double-Throw 0/0Vac Pole (Non-Fusible) 0Vac Pole (Fusible) 0Vac Pole (Non-Fusible) 600Vac Heavy Duty Pole (Fusible & Non-Fusible) 600Vdc Pole (Fusible) 600Vac /X Pole (Non-Fusible) 600Vac & Pole (Fusible) 0Vdc Mill Duty Pole (Fusible & Non-Fusible) 600Vdc Pole (Fusible & Non-Fusible) 600Vac 5/ Heavy Duty Pole (Fusible & Non-Fusible) 600Vdc Pole (Fusible) 600Vac (also available in R) Pole (Non-Fusible) 600Vac Mill Duty & Pole (Fusible) 0Vdc Pole (Fusible & Non-Fusible) 600Vdc Pole (Fusible & Non-Fusible) 600Vac Safety Switch Nomenclature TH N 6 J DC Switch Fusing Number Number Maximum Ampere Enclosure Other Type of Wires of Poles Voltage Rating Type Features Rating TG = General Duty N = Non-Fusible = wire system = Poles = 0 Vac = 0 amps (Blank) = NEMA Type B = Bottom Feed TH = Heavy Duty (blank) = Fusible = wire system = Poles 6 = 600 Vac = 60 amps J = NEMA 5/ CL = Copper Lugs = wire system 6 = 6 Poles = 00 amps M = NEMA (MILL DUTY) DC = 600 Vdc Rated = 00 amps R = NEMA Type R F = Vertically Hinged Door 5 = 00 amps SS = NEMA /X (0SS) W = Viewing Window 6 = 600 amps SS6 = NEMA /X (6SS) Nomenclature provided for interpreting product numbers only.

General Duty Safety Switches GE s Type TG general duty safety switches are designed for residential and light commercial applications where duty is not severe. They are available in 0-600 amps, 0 Vac, 50 Vdc maximum in both fusible and non-fusible units, and in NEMA Type (indoor) and Type R (outdoor) enclosures. The UL Listed short-circuit rating is 0,000 rms symmetrical amps as standard. When Class R fuses and fuse kits are installed, 0-00 amp switches have a UL Listed short circuit rating of 00,000 rms symmetrical amps. GE s general duty safety switches are UL Listed as service entrance equipment when installed in accordance with the National Electrical Code. All GE general duty safety switches are UL Listed and CSA certified (UL98 Enclosed Switches/CSA-C. No. -0) and meet NEMA Enclosed Safety Switch Standard KS-00. 6 9 7 5 8 Best suited for residential and light commercial applications. Available in indoor (Type ) and outdoor (Type R) enclosures. Highly visible ON/OFF label takes the guesswork out of safety and gives a clean, modern appearance. Bright red handle is easy to see, easy to grip. Direct-drive, quick-make, quick-break mechanism snaps the contacts open and closed, providing positive ON/OFF indication while prolonging switch life. 5 Wide, unobstructed gutter and removable interior make wire pulling and lug connections quick and easy. 6 Three-point mounting pattern speeds installation and simplifies ganging in close quarters. 7 Plated stationary and movable contacts deliver reliability and long life. 8 Galvanized steel enclosure offers superior rust protection in outdoor applications. There s also a durable polyester powder-coat finish. 9 Plated blades provide visible confirmation of contact position.

Heavy Duty Safety Switches GE s Type TH heavy duty safety switches are designed for commercial and industrial applications where safety, high performance and continuity of service are essential. Heavy duty switches are available in 0-00 amps, 600 Vac, 600 Vdc maximum, fusible and non-fusible units, and in NEMA Type (indoor), Type R (outdoor), Type /X (water and dust-tight, corrosion resistant), and Type 5/ (drip and dust-tight) enclosures. When used with Class R or J fuses, 0-600 amp switches have a UL Listed short-circuit rating of 00,000 rms symmetrical amps. Switches rated 800-00 amps use Class L fuses and have a UL Listed short circuit rating of 00,000 rms symmetrical amps. GE s heavy duty safety switches are UL Listed as service entrance equipment when installed in accordance with the National Electrical Code. All GE heavy duty safety switches are UL Listed and CSA certified (UL98 Enclosed Switches/CSA-C. No. -0), meet Federal Specification WS-865C for heavy duty switches and meet NEMA Enclosed Safety Switch Standard KS-00. 6 7 8 9 5 0 Best suited for commercial and industrial applications. Highly visible ON/OFF label takes the guesswork out of safety and gives a clean, modern appearance. Bright red donut handle, molded from rugged SE Noryl thermoplastic, is easy to see, easy to grip and ideal for hook stick operation. It accepts three padlocks in OFF position. Coin-proof, defeatable dual interlocks meet all safety inspection requirements. 5 Wide, unobstructed gutter and removable interior make wire pulling and lug connections quick and easy. 6 Three-point mounting pattern speeds installation and simplifies ganging in close quarters. 7 Exclusive SE Noryl thermoplastic arc shield helps provide maximum UL Listed horsepower ratings while guarding against accidental contact with live parts. 8 Accessories, such as auxiliary switch kits, are UL Listed for quick and easy field installation (or they may be factory installed). 9 Plated blades provide visible confirmation of contact position. 0 Direct-drive, quick-make, quick-break mechanism snaps the contacts open and closed, providing positive ON/OFF indication while prolonging switch life. Spring-reinforced fuse clips assure reliable contact for cool operation. Suitable for Class H, K, J or R fuses. Cu-Al lugs are 60/75 C rated to permit greater wire selection. Galvanized steel enclosure offers superior rust protection in outdoor applications. There s also a durable polyester powder-coat finish.

Mill Duty Safety Switches GE s mill duty safety switches are designed specifically for the rugged conditions found in steel mills, cement foundries and other process-related environments. Mill duty switches are available in 0-600 amps, 600 Vac, 600 Vdc maximum, fusible and non-fusible units, and in NEMA Type /X (water and dust-tight, corrosion resistant) and Type (drip and dust-tight) enclosures. Horsepower ratings are to UL Listed maximums; published I t ratings are available. Short circuit ratings are UL Listed to 00,000 rms symmetrical amps when Class J or R fuses are installed. All GE mill duty safety switches are UL Listed and CSA certified (UL98 Enclosed Switches/CSA-C. No. -0), meet Federal Specification WS-865C for heavy duty switches and meet NEMA Enclosed Safety Switch Standard KS-00. 5 8 6 7 Best suited for rugged environmental conditions such as mills and foundries. Bright red donut handle molded from rugged SE Noryl thermoplastic is easy to see, easy to grip and ideal for hook stick operation. It accepts three padlocks in OFF position. Manual interlock defeat lever permits contact inspection when switch is OFF. Standard NEMA enclosure protects interior from dust, lint, fibers, coolants, metal filings and other non-corrosive contaminants. Stainless steel NEMA /X enclosure additionally shields interior from hose directed water, splashing and falling liquids. Interlocks on all enclosure covers assure gasket compression before switch can be turned ON. 5 Efficient space-saving enclosures, three-point mounting, unobstructed side wiring gutter, easily removable cover and interior. 6 Spring-reinforced fuse clips assure reliable contact for cool operation. Suitable for Class H, K, J or R fuses. 7 Equipment ground lugs provided. Lugs approved for both copper and aluminum wire; 60/75 C rated tang lugs are field convertible to compression (crimp) connectors. 8 Highly visible ON/OFF label takes the guesswork out of safety and gives a clean, modern appearance.

Double-Throw Safety Switches Bright red donut handle molded from rugged SE Noryl thermoplastic is easy to see, easy to grip and ideal for hook stick operation. Highly visible ON/OFF label takes the guesswork out of safety and gives a clean, modern appearance. Three position (ON-OFF-ON) handle is lockable. Lockable cover latch and defeatable interlock meet all safety inspection requirements. GE s Type TC and TDT double-throw safety switches are designed for applications where safety, high performance and continuity of service are essential. Double-throw switches are available in 0-600 amps, 600 Vac, 50 Vdc maximum in fusible and non-fusible construction, and in NEMA Type (indoor) and Type R (outdoor) enclosures. GE s double-throw safety switches are UL Listed as service entrance equipment when installed in accordance with the National Electrical Code. All GE double-throw safety switches are UL Listed (UL98 Enclosed Switches) and meet NEMA Enclosed Safety Switch Standard KS-00 for type HD 0-00 amps and type GD 00-600 amps. Emergency Power Transfer Switches 6 A wide range of interchangeable rain-tight conduit hubs are available. Code-gauge steel box is fitted with a drip-shield for protection against rain; resists corrosion, rust and chipping. Plated copper current-carrying parts prevent oxidation to assure low-resistance contact and cool operation. Mounting holes permit quick, easy installation. 5 Bonding strap can be used to ground neutral for service entrance applications. 6 Ample wiring space provided within compact enclosure. 7 Positive make and break is provided by fiber loop straps between knife blade contacts and one-piece operating yoke. 8 Provision for handle locking in ON or OFF position protects against accidental contact with live parts. 9 Concentric knockouts are conveniently located, easy to remove. 0 Galvanized steel enclosure, offers superior rust protection in outdoor applications. There s also a durable polyester powder-coat finish. 8 7 9 0 5 GE s Type TC emergency power transfer switches are specifically designed to permit the connection of power from a standby generator or other emergency source of electricity and are ideally suited for outdoor applications in rural dwellings and farm buildings. Emergency power transfer switches are non fusible and are available in 00-00 amps for 0/0V three-wire systems and in 00 amps for 0V four-wire systems and in NEMA Type R (outdoor) enclosures. The side operated handle can be locked in either the ON or OFF position. Type TC emergency power transfer switches are UL Listed (UL98 Enclosed Switches) and are suitable for use as service entrance equipment when installed in accordance with the National Electrical Code.

Enclosure Types NEMA enclosures are suitable for indoor use, primarily to provide protection against contact with the enclosed equipment and where unusual service environments do not exist. NEMA R enclosures are intended for outdoor use to provide a degree of protection against falling rain, sleet and external enclosure ice formation. NEMA /X enclosures are intended for indoor or outdoor use to provide a degree of protection against windblown dust and rain, and splashing or hose-directed water and external enclosure ice formation. Additionally, these enclosures meet X requirements by providing a degree of protection against corrosion. NEMA 5/ enclosures are intended for indoor use primarily to provide a degree of protection against settling airborne and circulating dust, falling dirt and dripping, non-corrosive liquids. Accessories GE safety switches provide a full line of factory and field installable accessories to meet your special requirements. Equipment Ground Kits: available for 0-600 amp safety switches Neutral Kits: available for 0-00 amp safety switches (insulated, groundable and bondable) Crimp Type Connector: available for 0-600 amp safety switches Viewing Window: available for select 0-00 amp heavy duty safety switches, NEMA Types /X and 5/ Auxiliary Contact Kits: available in both single pole double-throw and double pole double-throw (listed for field installation) Class J Fuse Conversion Kits: available for 600 amp safety switches Class R Fuse Kits: available for 0-600 amp safety switches Raintight Aluminum Hubs: available up to " conduit diameter Special Purpose GE Safety Switches GE provides the following special purpose safety switches to satisfy a variety of unique applications: Six-Pole Switches: available in 0-00 amps, 600 Vac, 50 Vdc maximum, fusible or non-fusible, NEMA Type enclosure. Interlocked Receptacle Switches: available in 60 amps, 600 Vac, fusible or non-fusible, NEMA Type enclosure. Plug-Fuse Switches: available in one and two-pole designs, 0 amps, 0 Vac maximum, NEMA Type enclosure. Air Conditioner Disconnects: available in 0-60 amps, fusible or non-fusible, NEMA Type R enclosure (steel or thermoplastic available). Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. GE Woodford Avenue, Plainville, CT 0606 www.geelectrical.com 009 General Electric Company imagination at work GEA-A (0/09)