GHN424NW HHN426N HUN361AW

Size: px
Start display at page:

Download "GHN424NW HHN426N HUN361AW"

Transcription

1 General Description GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the development and manufacturing processes, switches have performed successfully in tests witnessed by Underwriters Laboratories. These tests include those for general purpose safety switches and those designed for more specialized purposes where applicable. Handle Lock-Off Heavy duty, H series safety switches have a provision to lock the handle in the OFF position with a maximum of three padlocks. Doors may be locked closed with a padlock. General duty, G series switches may be locked in the OFF position with one padlock. There is also a padlock feature for locking the door. General and Heavy Duty Switches Feature a Time Proven Design A fast, long lasting switch design with a clean, continuous contact. That s the switching system that gives you on-going reliability. The concept is simple: split the arc to shorten the break distance. Uncomplicated mechanics and common sense design assure reliable performance time after time. All switches through 1200A feature visible blade contruction. Load Break Ratings All Murray safety switches are UL Listed for load break applications. Included in this process is a series of repeated make and break tests of the switch contacts while carrying the full rated nameplate current and rated voltage. Horsepower Ratings Where permitted, all Murray safety switches are UL horsepower Listed. The switch ratings are determined by tests that have been performed successfully in the UL overload test series, including repeated make and break tests of the stalled motor current of the motor for which it is being rated. Some switches have two or more ratings for a particular voltage and current, and additional ratings if designed for multi-pole applications. Depending on the switch and its application, various ratings may be assigned. All switches list the ratings on the inside of the cover or the door. The ampere rating and maximum AC voltage rating are always shown on the nameplate on the front of the switch. Fault Current Performance Murray Heavy Duty safety switches have successfully passed UL high level fault current tests. This means the risk of mechanical and thermal damage due to high level short circuit currents is minimized due to the reliable switch design. Suitability tests for service with Class H, R, J, L, and T fuses have been conducted on heavy duty safety switches. Representative switches, with test fuses connected in series with each switch, were subjected to let-throughs in excess of the capacities of the largest fuses acceptable by the switches. To pass the test, the switch must remain operable after being closed into a high amp available short circuit current. The test fuse is sized so that higher levels of let-through current and energy will be reached than would ever occur during normal usage in the field. Murray General Duty safety switches have been tested to allow installation on circuits capable of delivering 100,000 AIC of fault current at 240V AC max. with Class R fuses and also with both Class J and T fuses in A ratings. Fuse Interchangeability General Duty Switches, Prefix G,* will accept the following UL class fuses: Class H Class K Class R Requires class R fuse kit to maintain UL listing. Class J A field convertible. Class T with proper adapter kit ( A). *Except 0 amp plug style switches. Heavy Duty Switches, Prefix H, will accept the following UL class fuses: Class H Class K Class R Requires class R fuse kit to maintain UL listing. Class J All 0 200A, 600V and A, 240V switches field convertible. Class L 800 and 1200A switches only. Class T A switches with proper adapter kit. Gutter Space G and H series safety switch gutter dimensions conform to 2008 NEC Article #12.6(A). Top and bottom gutters conform to Table #12.6(B). MURRAY -9

2 Technical Information MURRAY General Duty Switches; Prefix G General duty switches are available in indoor TYPE 1 and outdoor TYPE R enclosures. Enclosures can be locked closed and operating handles can be locked off. Series G switches have a quick-make, quick-break mechanism. Fusible switches are available in 1 pole S/N, 2 pole S/N and pole S/N configurations. Non-fusible switches are available in pole configurations. General duty switches are limited to 240V AC, 200 max. rating. All 0 Amp compact fusible and non-fusible G prefix switches are rated 10,000 Amp maximum withstand. All Amp GF and GU prefix switches are suitable for use on systems capable of delivering not more than 100,000 RMS symmetrical of fault current with Class R fuses and the appropriate adapter kit installed. These Amp G prefix switches may also be used on systems capable of delivering not more than 100,000 RMS symmetrical of fault current with T fuses and the appropriate adapter kit installed. In addition, general duty switches may also be used with J fuses on systems not capable of delivering more than 100,000 RMS symmetrical amperes of fault current. General duty switches are UL Listed for use as service equipment and are horsepower rated for use with motor loads. General duty enclosed switches are used for light duty applications where loading and switching operations are not excessive. Heavy Duty Switches, Single Throw; Prefix H Heavy duty switches are available in indoor TYPE 1, outdoor TYPE R, Watertight Type 4/4X, and industrial TYPE 12 enclosures. Dual cover interlocks are provided, such that the door cannot be opened with the switch ON and the switch cannot be turned ON with the door open. A defeat mechanism allows servicing by authorized personnel. Handles may be locked OFF with up to padlocks, and doors may be padlocked closed. Mechanism is TEASE-PROOF quick-make, quick-break. Fusible switches are available in 2 pole S/N, pole and pole S/N. Non-fusible switches are available in pole. Suitable for use on systems capable of delivering not more than 200,000 RMS symmetrical amperes of fault current when Class J or R fuses are installed except the 800 and 1200A switches, which are suitable for use on circuits capable of delivering not more than 200,000 RMS symmetrical amperes of fault current when Class L fuses are installed A switches with Class T fuses and field adapter kit 200,000 RMS symmetrical rated. Heavy duty switches are dual horsepower rated and are listed by UL for use as service entrance equipment. Heavy duty switches are intended for applications where rugged construction, reliable performance, continuity of service and ease of maintenance are required. Protector-Lock Switches; Prefix H The Murray Protector-Lock switch is designed to eliminate shock hazard due to disconnecting heavy duty portable electrical equipment under load. When the switch is in the ON position, the safety bar blocks the self-contained receptacle and prevents insertion or removal of the plug. When the switch is OFF, the bar retracts, allowing insertion or removal of the plug. Protector-Lock switches consist of a heavy duty, 0 or 60 Amp, 600V AC, pole fusible or non-fusible enclosed switch, and either Crouse-Hinds or Arrow Hart Industrial receptacles. Applications include industrial plants where portable conveyors and welders are used, and truck terminals where on-board refrigeration units require stand-by power. Double Throw Switches; Prefix HD Double throw switches are available in TYPE 1 and TYPE R enclosures. Covers are dual interlocked with the operating mechanism such that the cover cannot be opened when the switch is in either ON position, and the switch handle cannot be moved to either ON position if the cover is open. Handle may be padlocked in the OFF position. Switching action is quick-make, quick-break in both ON positions. They are available in Amp ratings, 240V AC, fusible and non-fusible, two and three pole. Double throw switches are usually applied as transfer switches to switch a load from one power source to another, but can be field converted to switch one power source between two loads. Switching mechanism is located on line side of fuses allowing for a safer fuse replacement. All are suitable for use as service equipment. Industry and Government Specifications Murray enclosed switches meet or exceed the latest revision of the following specifications: Industry NEMA Standard #KS UL-Standard #98 U.S. Government HD single throw, prefix H : Standard #WS-865c type HD HD double throw, prefix HD : Standard #WS865c type NDD GD Amp, prefix G : Standard #WS 865c type ND ; except where interlock is required. GD 0 Amp, prefix G : Standard #WS-865c type ND ; except where interlock is required. Arrow Hart and Crouse-Hinds are registered trademarks of Cooper Industries, Inc. Protector-Lock is a registered trademark of Siemens Energy & Automation Inc. -40 Product Category GDSM and HDSM

3 General Duty Compact 10,000 Amp Withstand Plug Fuse Type 1 & Type R GU221 GP21N General Duty Compact Fuse Type Indoor TYPE 1 Accessories and Lug Data See pages -48 and -49. Dimensions See pages -50, -51 and -52. Knockout Drawings See page -5. Std. Pkg. Outdoor TYPE R Std. Pkg. Hub Figure 1 Figure 2 Figure Figure 4 Horsepower Rating Single Phase Three Phase 120V AC 240V AC 240V AC Std Max a Std Max a Std Max a 0 AMP FUSIBLE 1 POLE 2 WIRE S/N 120V AC (INSULATED GROUNDABLE NEUTRAL) Fig-1 Plug GP211N AMP FUSIBLE 2 POLE WIRE S/N 240V AC (INSULATED GROUNDABLE NEUTRAL) Fig-2 Plug GP21N GP21NW ECHA Fig- None GU GU221AW ECHA 2 60 AMP NON-FUSIBLE 2 POLE 240V AC SPECIAL APPLICATION SWITCH Fig-4 None GU222AW b 10 Hubs Conduit Size (Inches) 4 ECHA ECHA ECHA (Std. Pkg. 1) MURRAY General Duty Stand-by Power Panel This unique device provides an economical means to transfer from normal to an alternate source of power. It contains two 100A, 2-pole circuit breakers interlocked in a double throw configuration and supplies both overload and short circuit protection (10,000 AIC max.). The external handle is padlockable in the OFF position. Outdoor TYPE Std. Pkg. Wgt. Lbs. 100A 2 POLE WIRE S/N 120/240V AC OUTDOOR TYPE R d Hub DUL1NW c ECHS N a Starting current of motors above standard horsepower rating may require use of time delay fuses. b Bottom cable entry & exit only. c Suitable for service entrance application. Neutral factory installed. UL1008 listed as a non-automatic transfer switch under file #E1500. Suitable for use as Transfer Equipment on optional stand-by systems as defined by Article 702 of the NEC. d Wire ranges (75 C Cu/Al) Line, load & neutral (1) #14-1 Service ground (1) #14-4 e Discount Schedule HDSM. Product Category GDSM -41

4 General Duty Amp, 10,000 & 100,000 Amp Withstand Cartridge Fuse Type 1 & Type R GUN22 GHN21N GHN42NW MURRAY Switch Selection with Class H Fuse Holders (Convertible to Class R ) a Indoor TYPE 1 Std. Pkg. Outdoor TYPE R Std. Pkg. FUSIBLE 2 POLE WIRE S/N 240V AC (INSULATED GROUNDABLE NEUTRAL) c de Hub Horsepower Rating Single Phase Three Phase 240V AC 240V AC 250V DC Std Max Std Max Std Fig-1 0 GHN21N c GHN21NW c ECHA GHN22N c GHN22NW c ECHS GHN2N c GHN2NW c ECHS GHN24N c GHN24NW c ECHS FUSIBLE POLE 4 WIRE S/N 240V AC (INSULATED GROUNDABLE NEUTRAL) e Fig-2 0 GHN421N GHN421NW ECHA GHN422N GHN422NW ECHS GHN42N GHN42NW ECHS GHN424N GHN424NW ECHS NON-FUSIBLE POLE 240V AC (SEE PREVIOUS PAGE FOR 2 POLE, 0 AMPS; USE POLE FOR 2 POLE APPLICATION FOR AMPS) Fig- 0 GUN GUN21AW ECHA GUN GUN22AW ECHS GUN GUN2AW ECHS GUN GUN24AW ECHS Accessories and Lug Data See pages -48 and -49. Dimensions See pages -50, -51 and -52. Knockout Drawings See page -5 and -54. Figure 1 Figure 2 Figure a G Series switches are UL Listed for use on circuits capable of delivering up to 100,000 RMS symmetrical fault currents, provided Class R or T fuses and appropriate rejection or adapter kits are installed. T-fuses can only be used on Amp A switches can also be used with Class J fuses. b Starting current of motors above standard horsepower rating may require use of time delay fuses. c These switches are UL Listed for application on grounded B systems. dsuitable for -pole motor loads. ehas service entrance label, neutral factory installed. -42 Product Category HDSM

5 Heavy Duty 240V AC, 10,000 & 200,000 Amp Withstand Cartridge Fuse Type 1 & Type R HHN422N HHN2NW HHN421NW Switch Selection with Class H Fuse Holders (Convertible to Class J, R or T ) a Indoor TYPE 1 Std. Pkg. Outdoor TYPE R Std. Pkg. FUSIBLE 2 POLE WIRE S/N 240V AC (INSULATED GROUNDABLE NEUTRAL) de h Hub Horsepower Rating Single Phase Three Phase 240V AC 240V AC 250V DC Std Max Std Max Std Fig-1 0 HHN21N HHN21NW ECHS HHN22N HHN22NW ECHS HHN2N HHN2NW ECHS HHN24N HHN24NW ECHS HLN27N bf HLN28N bf FUSIBLE POLE 4 WIRE S/N 240V AC (INSULATED GROUNDABLE NEUTRAL) e h Fig-2 0 HHN421N HHN421NW ECHS HHN422N HHN422NW ECHS HHN42N HHN42NW ECHS HHN424N HHN424NW ECHS HLN427N bf HLN427NW bf ECHV g HLN428N bf HLN428NW bf ECHV g MURRAY Accessories and Lug Data See pages -48 and -49. Dimensions See pages -51 and -52. Knockout Drawings See pages -5 and -54. Figure 1 Figure 2 a Switches through 1200 listed by Underwriters Laboratories for use on circuits delivering up to 200,000 RMS symmetrical fault current, provided class R, J, L, or T fuses are used. Rejection kits must be installed for R fuse application. T fuse adapter kit required for T fuse application. See Accessory Page. J fuses can only be used on A ratings. T fuses can only be used on A ratings. b Factory set for use with class L fuses. c Starting current of motors above standard horsepower rating may require use of time delay fuses. dsuitable for -pole motor loads. e Suitable for service entrance application. Neutral factory-installed. f Supplied without knockouts. g 800A and larger Type R switches have no provisions for mounting hubs. Drill or punch hole in the field to accommodate hub size desired. h Also rated 250V DC Product Category HDSM -4

6 Heavy Duty 600v AC, 10,000 & 200,000 Amp Withstand Cartridge Fuse Type 1 & Type R HHN61AW HHN64 Plus Neutral HN64M MURRAY Switch Selection with Class H Fuse Holders (Convertible to Class J, R or T ) a Indoor TYPE 1 Outdoor TYPE R (Std. Pkg. 1) (Std. Pkg. 1) Hub Horsepower Rating 480V AC 1Ø 480V AC Ø 600V AC 1Ø 600V AC Ø Std Max Std Max Std Max Std Max FUSIBLE POLE 600V AC (NO NEUTRAL) ef Fig-1 0 HHN HHN61AW ECHS HHN HHN62AW ECHS HHN HHN6AW ECHS HHN HHN64AW ECHS HLN67 b HLN67AW b ECHV g HLN68 b 8.00 HLN68AW b ECHV g FUSIBLE POLE 4 WIRE S/N 480Y / 277V AC (INSULATED GROUNDABLE NEUTRAL) f Fig-2 0 c HHN461NW ECHS c HHN462NW ECHS NON-FUSIBLE POLE 600V AC (USE FOR 2 POLE) efi Fig- 0 HUN HUN61AW 1.00 ECHS HUN HUN62AW ECHS HUN HUN6AW ECHS HUN HUN64AW ECHS V DC 600V DC Accessories and Lug Data See pages -48 and -49. Dimensions See pages -51 and -52. Knockout Drawings See pages -5 and -54. Figure 1 Figure 2 Figure a Switches through 1200 listed by Underwriters Laboratories for use on circuits delivering up to 200,000 RMS symmetrical fault current, provided class R, J, L, or T fuses are used. Rejection kits must be installed for R fuse applications. b Class L fuse provision. Single fuse per pole. Supplied without knockouts. c Order pole switch from chart above, and neutral from accessory page. d Starting current of motors above standard horsepower rating may require use of time delay fuses. e For service equipment or applications requiring a solid neutral, order neutral kit as an accessory, page -8. f A switches are also rated 600V DC when 2 poles are connected in series. g 800A and larger Type R switches have no provisions for mounting hubs. Drill or punch hole in the field to accommodate hub size desired. i Non-fusible switches also have the following max. HP ratings. 1Ø 240V AC Ø 240V AC Product Category HDSM

7 Heavy Duty 600V AC, 10,000 & 200,000 Amp Withstand Cartridge Fuse Industrial Type 12 & 4X HUN61AJ Accessories and Lug Data See pages -48 and -49. Dimensions See pages -51 and -52. Figure 1 Figure 2 Switch Selection With Class H Fuse Holders (Convertible To Class J, R or T ) a Industrial Type 12 (Std. Pkg. 1) FUSIBLE POLE 600V AC (NO NEUTRAL) cf Horsepower Rating 480V AC Ø 600V AC Ø Std Max Std Max 250V DC 600V DC Fig-1 0 HHN61AJ HHN62AJ HHN6AJ HHN64AJ NON-FUSIBLE POLE 600V AC (USE FOR 2 POLE) cef Fig-2 0 HUN61AJ HUN62AJ HUN6AJ HUN64AJ Type 4X Stainless Steel (Std. Pkg. 1) FUSIBLE POLE 240V AC (NO NEUTRAL) cd Horsepower Rating 480V AC Ø 600V AC Ø Std Max Std Max 250V DC 600V DC Fig-1 0 HHN21AS e e 5 60 HHN22AS e e 10 FUSIBLE POLE 600V AC (NO NEUTRAL) cf Fig-1 0 HHN61AS HHN62AS HHN6AS HHN64AS NON-FUSIBLE POLE 600V AC (NO NEUTRAL) cdef Fig-2 0 HUN61AS HUN62AS HUN6AS HUN64AS MURRAY a Switches through 200 listed by Underwriters Laboratories for use on circuits delivering up to 200,000 RMS symmetrical fault current, provided class J, R or T fuses are used. Rejection kits must be installed for R fuse applications. b Starting current of motors above standard horsepower rating may require use of time delay fuses. For service equipment or applications requiring a solid neutral, order neutral kit as an accessory, page -8. Use pole switch for 2 pole applications. 240V Ø HP ratings are as follows: HP Max. HP Max. HP Std Fusible Non-Fusible A switches are also rated 600V DC when 2 poles are connected in series. Product Category HDSM -45

8 VBII Type Double Throw Switches Type 1 & Type R HNC264M HDHN22 HDUN6AW MURRAY Double Throw Switches a Indoor TYPE 1 Outdoor TYPE R Wgt. Lbs. Hub Horsepower Rating NON-FUSIBLE 2 POLE 240V AC Fig-1 0 HDUN HDUN HDUN HDUN HDUN224AW ECHS NON-FUSIBLE POLE 240V AC Fig-2 0 HDUN HDUN HDUN HDUN2AW ECHS HDUN HDUN24AW ECHS FUSIBLE POLE 240V AC Fig- 0 HDHN HDHN21AW 9.00 ECHS HDHN HDHN22AW ECHS HDHN HDHN2AW ECHS HDHN NON-FUSIBLE POLE 600V AC Fig-2 0 HDUN HDUN61AW 5.00 ECHS HDUN HDUN62AW 7.00 ECHS HDUN HDUN6AW 8.00 ECHS HDUN HDUN64AW ECHS Ø Std 1Ø Max Ø Std Ø Max 250V DC Neutral Kits For use with Double Throw Switches Switch 0 HNC612M HN26M 200 HNC264M Figure 1 Figure 2 Figure Fuse Capabilities of Fusible Switches Amp Rating Fuse Type H R T J 0 & 60 A Std Yes (kit) No No 100 & 200A Std Yes (kit) Yes (kit) Yes 5 Double Throw Switches Lug Data Switch Amp Range of Cables Per Terminal Cu and/or Al Wire Range 0 1 pc. Cu or Al #14 to # pc. Cu or Al #14 to # pc. Cu or Al #14 to #1/ pc. Cu or Al #6 to 250 kcmil 1 Rated 10,000 AIC with Class H or 200,000 AIC when used with or protected by Class R, J or T fuses. Fuse rating must not exceed switch ampere rating A and larger double throw switches do not have a hub provision. Typical wiring diagrams for amp switches are shown. 4 HP ratings at 480V. 5 Move load side base. 6 General Duty Double Throw Switches are also available in 100 and 200A ratings. Contact sales for additional info. 7 A 100A 2P General Duty Stand-by Power Panel is also available on page Product Category HDSM

9 Protector-Lock Switches HHN62CJ Protector-Lock Switches With Arrow Hart Power Lock Receptacles Industrial Enclosure Switch Recept (Std. Pkg. 1) Use Plug # b FUSIBLE, POLE 600V AC SWITCH Fig HHN61KJ AX10S 20415S 60 0 HHN62KJ a AX10S 20415S HHN62LJ S Figure 1 Figure 2 Protector-Lock Switches With Crouse-Hinds Receptacles Industrial Type 12 Switch Recept (Std. Pkg. 1) Use Plug # b FUSIBLE, POLE 600V AC SWITCH (STYLE 2 RECEPTACLE, 4 WIRE, ONE WIRE GROUNDED) Fig HHN62CJ 0.00 APJ6485 NON-FUSIBLE, POLE 600V AC SWITCH (STYLE 2 RECEPTACLE, 4 WIRE, ONE WIRE GROUNDED) Fig HUN62CJ APJ6485 MURRAY Accessories and Lug Data See pages -48 and -49. Dimensions See pages -51 and -52. anot UL listed. bsee Accessories page -49 for plug selection. Arrow Hart, Power Lock, & Crouse-Hinds are registered trademarks of Cooper Industries, Inc. Protector-Lock is a registered trademark of Siemens Energy & Automation, Inc. Product Category HDSM -47

10 Accessories HN612M HT6M HR612M MURRAY HA16124M HA26124M Neutral Kits a Standard Neutral Kits can be field installed in General and Heavy Duty Switches. Switch Ampere Rating Kit 0 GD W410190M 0 HD, 60 GD HN612M 60, 100 HD, 100 GD HN62M 200 HN64M 800 & 1200 VBII HN678M Class T Fuse Adapter Kits c All 200A General Duty and A Heavy Duty Switches are field convertible to accept Class T fuses. HT2M d HT6M HT24M d HT64M HX27TF Description 100A, 240V Kit 100A, 600V Kit 200A, 240V Kit 200A, 600V Kit 800A, 240V Kit Class R Fuse Clip Kits b GSRK21M HR21M HR612M HR62M HR6M HR64M Description 0A, 240V Kit (GD only) 0A, 240V Kit (HD only) 0A, 600V Kit/60A, 240V Kit 60A, 600V Kit 100A Kit 200A Kit HX67TF 800A, 600V Kit HX28TF 1200A, 240V Kit Equipment Ground Kits Equipment Ground Lug Kits are available for all General Duty, Heavy Duty and Double Throw Switches. They are field installable in Type 1 and Type R Switches and are factory installed as standard in Type 4/4X and Type 12 Switches. Switch Ampere Rating of Terminals Wire Range Per Terminal (Cu/Al) 0A GD GSGK60M 2 #14-8 AWG GD HG6124M 2 #14-4 AWG HD HG6124M 2 #14-4 AWG HG678M 8 #6 AWG-250 Kcmil Class J Fuse All A General Duty and 600V 0-200A Heavy Duty Switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. a All neutral kits are provided with a grounding lug and also contain a bonding provision. b One kit per switch required for General and Heavy Duty switches. Two kits required per Doubble Throw Switch. c(1) kit per pole required. 100 and 200A Double Throw switches are also convertible from H to T fuses by using (6) kits per switch. -48 Product Category HDSM

11 Accessories & Lug Data Type VBII R Hubs a (60 600A GD A HD) Conduit Size (Inches) Compact & 0A GD Switch Hubs Conduit Size (Inches) Closure Plates Std. Pkg. Ship. Wgt. (Std. Pkg.) 4 ECHA ECHA ECHA Rating ECHS000 f ECHV A HVHRA d A For Use on Switches Rated 4 ECHS A HD, AGD 1 ECHS A HD, AGD ECHS A HD, AGD ECHS A HD, AGD 2 ECHS A HD, AGD ECHS A HD, AGD ECHV A ce ECHV A ce 1 2 ECHV A ce 4 ECHV A ce (Std. Pkg. 1) Plugs for Protector-Lock Switches b General & Heavy Duty Switches Lug Data 0-100A Switches are suitable for use with 60 or 75 C wire A are suitable for use with 75 C rated wire. Wire Ranges (Line, Load and Standard Neutral) Switch Ampere Rating Auxiliary Contacts g Auxiliary Contacts are available only for Heavy Duty and Double Throw Switches. The auxiliary contacts are available in 1 normally open and 1 normally closed or 2 normally open and 2 normally closed configurations. All auxiliary contacts make after and break before the main switch contacts. Switch Ampere Rating Wire Range with Wire-Bending Space Per NEC Table 7-6 Aux. Switch Kit Ampere Rating 125V AC 250V AC (Std. Pkg. 1) Rating Description APJ A, 600V AC High impact strength, copper-free aluminum. Accepts diameter cord. AX10S.80 0A, 600V AC Armored steel with cord grip. Accepts diameter cord. Lug Range 0 GD #14-8 AWG (Cu/Al) h #14-8 AWG (Cu/Al) h 0 #12-6 AWG (Al) or #14-6 AWG (Cu) #14-2 AWG (Cu/Al) 60 #12- AWG (Al) or #14- AWG (Cu) #14-2 AWG (Cu/Al) 100 #14-1/0 AWG (Cu/Al) #14-1/0 AWG (Cu/Al) 200 #6 AWG-00 Kcmil (Cu/Al) #6 AWG-00 Kcmil (Cu/Al) 800 () /0 AWG-750 Kcmil (Cu/Al) Line and Load or () 1/0 AWG-750 Kcmil (Cu/Al) Line and Load or (6) /0 AWG-250 Kcmil (Cu/Al) (6) 1/0 AWG-600 Kcmil (Cu/Al) neutral (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral 1200 (4) /0 AWG-750 Kcmil (Cu/Al) or (4) 1/0 AWG-750 Kcmil (Cu/Al) Line and Load (4) 1/0 AWG-600 Kcmil (Cu/Al) neutral (4) 1/0 AWG-600 Kcmil (Cu/Al) neutral 28V DC Kit Horsepower Rating 125V AC 250V AC 28V DC Max. Max. Max. Max. Max. Max. With 1 NO & 1 NC Isolated Contacts HA16124M /2 / HA165678M /2 /4 With 2 NO & 2 NC Isolated Contacts HA26124M /2 / HA265678M /2 /4 MURRAY a Also for double throw switches. Not for use on compact switches. bnet Price. No discount. 800A and larger Type R switches have no provisions for mounting hubs. Drill or punch hole in the field to accommodate hub size desired. HV to HR adapter plate. Order ECHR series hub separately. For gasket kit for HV type hub order catalog number HVGKM. f A GD, 0-200A HD g Two auxiliary contacts required per double throw switch. h Connector will accept up to #6; conductors on line side and retain UL listing. Also applies to 0 compact switches. i Max. wire size for height reduced switches is 500 kcmil (Cu/Al). Product Category MURR and HDSM -49

12 A A A A A Dimensions Compact Switches, General Duty Switches E G E G B or C B or C B or C D E Type 1 or R 0A GD F G D Type 1 or R A GD, 0-200A Type VBII F D Type 4/4X or A Type VBII F MURRAY E G E G B or C B or C D Type 1 or R A Type VBII F D Type 4/4X or A Type VBII F Safety Switch Dimensions b Height Width Depth With With With With Box Door Rain Shed Box Handle Box Handle Knockout A B C D E F G Diagram a GHN21N S1 GHN21NW S GHN22N S6 GHN22NW S8 GHN2N S10 GHN2NW S11 GHN24N S12 GHN24NW S1 GHN25N S14 GHN25NH S14 GHN25NW S15 GHN25NWH S15 GHN26N S14 GHN26NH S14 GHN26NW S15 GHN26NWH S15 GHN421N S2 GHN421NW S4 GHN422N S6 GHN422NW S8 GHN42N S10 GHN42NW S11 GHN424N S12 GHN424NW S1 GHN425N S14 GHN425NH S14 GHN425NW S15 GHN425NWH S15 GHN426N S14 GHN426NH S14 GHN426NW S15 GHN426NWH S15 GP211N S2 GP21N S1 GP21NW S GU S1 a Knocks not provided on Type 4/4X and 12 or in 800 & 1200A Switches. -50 b Accurate to ± 1 8".

13 Dimensions General & Heavy Duty Switches Safety Switch Dimensions b Height d Width Depth With With With With Box Door Rain Shed Box Handle Box Handle Knockout A B C D E F G Diagram a GU221AW S5 GU222AW S5 GUN S2 GUN21AW S4 GUN S7 GUN22AW S9 GUN S10 GUN2AW S11 GUN S12 GUN24AW S1 HHN21AS HHN21N S6 HHN21NW S8 HHN22AS HHN22N S16 HHN22NW S17 HHN2N S10 HHN2NW S11 HHN24N S12 HHN24NW S1 HHN S6 HHN61AJ HHN61AS HHN61AW S8 HHN S16 HHN62AJ HHN62AW S17 HHN62AS HHN62CJ c HHN61KJ c HHN62KJ c HHN62LJ c HHN S10 HHN6AJ HHN6AS HHN6AW S11 HHN S12 HHN64AJ HHN64AS HHN64AW S1 HHN421N S6 HHN421NW S8 HHN422N S16 HHN422NW S17 HHN42N S10 HHN42NW S11 HHN424N S12 HHN424NW S1 HHN461NW S8 HHN462NW S17 HLN27N HLN28N HLN HLN67AW MURRAY a Knocks not provided on Type 4/4X and 12 or in 800 & 1200A Switches. b Accurate to ± 1 8". cdimensions are for switch less receptacle and mounting feet. ddimensions are less mounting feet on Type 12 and 4X switches. -51

14 MURRAY Dimensions General & Heavy Duty Switches, Protector-Lock Switches, Double Throw Switches Safety Switch Dimensions cd Height Width Depth With With With With Box Door Rain Shed Box Handle Box Handle Knockout A B C D E F G Diagram a HLN HLN68AW HLN427N HLN427NW HLN428N HLN428NW HUN S7 HUN61AJ HUN61AW S9 HUN61AS HUN S16 HUN62AJ HUN62AW S17 HUN62AS HUN62CJ b HUN S10 HUN6AJ HUN6AS HUN6AW S11 HUN S12 HUN64AJ HUN64AS HUN64AW S1 E VBII Design Double Throw Dimensions (Inches) 5 Enclosure Mounting A B C D E F (0-600A Type 1 & R) 5 HDUN221, HDUN21, HDUN61, HDUN61AW HDHN21, HDHN21AW HDUN222, HDUN22, HDUN62, HDUN62AW HDHN22, HDHN22AW D.5 A HDUN22, HDUN2, HDUN2AW, C L HDUN6, HDUN6AW HDHN2, HDHN2AW HDUN224, HDUN24, HDUN224AW HDUN24AW, HDUN64, HDUN64AW HDHN (6) F Dia. mounting holes (0-200A) (4) F Dia. mounting holes ( A) E E C B a Knockouts not provided on Type 4/4X and 12 or on 800 & 1200A switches. b Dimensions are for switch-less receptacle & mounting feet. c Accurate to ± 1 8". d For dimensions in millimeters, multiply inches by Drip hood not shown but supplied on Type R enclosures. (6) (6) F F Dia. Dia. mounting holes holes (0-200A) (4) (4) F F Dia. Dia. mounting holes holes (6) ( A) ( A) F Dia. mounting holes (0-200A) (4) F Dia. mounting holes ( A) -52 D C L D C L This mounting hole omitted on 0-100A Non-Fusible switches A A C

15 Knockout Drawings S1 S2 S Removable plate covering HA Type Hub opening (Max Conduit) S4 S1 4 K.O.'s for Conduit in. 7 K.O.'s for Conduit in. S4 Embossed.25 in. mounting holes (4 places) Removable plate covering HA Type Hub opening (Max Conduit) Embossed.25 in. mounting holes ( places) 2 K.O.'s for Conduit in. 4 K.O.'s for Conduit in. S5 S2 S5 Embossed.25 in. mounting holes (4 places) 2 K.O.'s for Conduit in. 10 K.O.'s for Conduit in. Embossed.25 in. mounting holes ( places) 2 K.O.'s for Conduit in. K.O.'s for Conduit in. S6 10 K.O.'s For Conduit 0.50, 0.75, 1 in. S6 S dia. K.O's Embossed.25 in. mounting holes ( places) 2 K.O.'s for Conduit in. K.O.'s for Conduit in. 4 K.O.'s for Conduit 0.75, 1 in. MURRAY S7 8 K.O.'s for Conduit 0.50, 0.75, 1 in. 4 K.O.'s for Conduit 0.75, 1 in. S8 Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S7 S dia. K.O's 2 K.O.'s for Conduit 0.75, 1 in. 5 K.O.'s for Conduit 0.50, 0.75, 1 in dia. K.O. -5

16 Knockout Drawings S9 Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S10 S11 Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S10 S9 S dia. K.O. MURRAY S12 2 K.O.'s for Conduit 0.75, 1 in. 5 K.O.'s for Conduit 0.50, 0.75, 1 in dia. K.O. S1 Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) 4 K.O.'s for Conduit 0.75, 1, 1.25, 1.50 in. 10 K.O.'s for Conduit 1, 1.25, 1.50, 2 in dia. K.O. S14 2 K.O.'s for Conduit 0.75, 1, 1.25, 1.50 in dia. K.O dia. K.O. 5 K.O.'s for Conduit 1, 1.25, 1.50, 2 in. S12 S14 S dia. K.O dia. K.O. 14 K.O.'s for Conduit 1.25, 1.50, 2.00, 2.50 in. 1, 0.25, dia. K.O 7 K.O.'s for Conduit 1.25, 1.50, 2.00, 2.50 in dia K.O. 8 K.O.'s for Conduit 2.00, 2.50,.00,.50 in , 0.75 dia. K.O.'s S15 S15 S16 S16 S17 Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S dia. K.O. 4 K.O.'s for Conduit 2.00, 2.50,.00,.50 in , 0.75 dia. K.O.'s 14 K.O.'s for Conduit 0.50, 0.75, 1, 1.25 in dia. K.O dia. K.O. 7 K.O.'s for Conduit 0.50, 0.75, 1, 1.25 in dia. K.O. -54

Selection and Application Guide Type VBII. safety

Selection and Application Guide Type VBII. safety Selection and Application Guide Type VBII safety You Asked for It. Murray Listened. Contents Features 4 Genral Duty Plug Fuse Type 5 General Duty Switches Features 6 General Duty Types 7 Heavy Duty Switches

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches Features 15 3 2 20 9 11 16 17 1 18 6 19 13 5 SAFETY 8 1 12 7 1. Quick-make, quick-break operating mechanism that ensures positive operation. 2. Visible blade, double-break switching action. 3. Arc chutes

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Cutler-Hammer January 1999

Cutler-Hammer January 1999 Cutler-Hammer General Description Description Safety switches have a number of applications from service entrance to branch circuit protection. They are also horsepower rated for use as motor circuit switches.

More information

1 SAFETY & DISCONNECT SWITCHES

1 SAFETY & DISCONNECT SWITCHES POWER PRODUCT Safety & Disconnect es Contents - Safety es Air Conditioning Disconnects - Safety Guide Form Specifications - Feature Comparison -6 Enclosure Types -7 ing System -8 General Duty Safety es

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

Plugs and Receptacles

Plugs and Receptacles Plugs and Receptacles Industrial Heavy Duty Interlocked Application and Selection Applications: Where extra protection is a requirement; interlocked units provide dead front receptacles; connection cannot

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

Safety Switches. Section 4. www.geindustrial.com

Safety Switches. Section 4. www.geindustrial.com For more information on these products, order publications from Section 27. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG...4-5 Heavy Duty, Type TH...4-7 Mill Duty, Type TH...4-14

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

Square D Safety Switches

Square D Safety Switches Square D Safety Switches Power isolation solutions for daily activities and emergencies TM Make the most of your energy SM Square D Safety Switches Setting the standard for perfomance, quality, and reliability

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects

Safety Switches DE2. Selection Guide. General Information. General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Selection Guide Contents Descriptions Page General Information Features and Benefits 2-3 Product Illustrations General Duty, Light Duty Safety Switches & Air Conditioning Disconnects Heavy Duty Safety

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

GUE, GUB Junction Boxes

GUE, GUB Junction Boxes E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

TSn SERIES Surge Protective Device

TSn SERIES Surge Protective Device Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 Sales@Systems.us Fax 804.355.8900 Page: 2 of 8 Quick

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1312-1313.qxp 12/16/2013 7:04 PM Page 1312 Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Features: Arktite circuit breaking plugs and receptacles are

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12 Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

CONDUCTOR SHORT-CIRCUIT PROTECTION

CONDUCTOR SHORT-CIRCUIT PROTECTION CONDUCTOR SHORT-CIRCUIT PROTECTION Introduction: This paper analyzes the protection of wire from fault currents. It gives the specifier the necessary information regarding the short-circuit current rating

More information

Low Voltage Fuses For Motor Protection

Low Voltage Fuses For Motor Protection Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.

More information

Mini Power-Zone Unit Substation

Mini Power-Zone Unit Substation Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Guidelines on the Short Circuit Current Rating for Industrial Control Panels usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A

More information

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper Low Voltage Disconnect Switches NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper Scope This document is intended to discuss the functional requirements for the disconnecting

More information

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC ELECTRICAL SERVICE REQUIREMENTS ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC TABLE OF CONTENTS TITLE SECTION NO. List of Approved Electric Utility Service Equipment Requirements Committee

More information

ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01)

ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01) ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01) Rule 28-900 Standby Generator Installations Due to the increasing number of standby generator installations being established to maintain continuity

More information

Cable/Conduit Conversion

Cable/Conduit Conversion Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Buck - Boost Transformers

Buck - Boost Transformers Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single

More information

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 PL Series Load Centers Features and Product Offering -4-5 PL Series

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront

More information

Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained

Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained Overhead Meters TABLE OF CONTENTS D D Consumer Service Pole for Mobile Home Park Temporary Service -wire Single Phase D. Overhead Meter Installation - Single Phase D. Connection Diagram - Single Phase

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility CenterPoint Energy (Reliant & HL&P).............................

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent

More information

FLB Series Circuit Breakers and Enclosures

FLB Series Circuit Breakers and Enclosures FLB Series Circuit Breakers and s Applications: FLB circuit breakers and enclosures are used: F service entrance, feeder branch circuit protection f lighting, heating, appliance and mot circuits In areas

More information

Continuous Power... Continuous Protection

Continuous Power... Continuous Protection Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1 Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

Requirements for Electrical Installations

Requirements for Electrical Installations ARTICLE 110 Requirements for Electrical Installations INTRODUCTION TO ARTICLE 110 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS Article 110 sets the stage for how you ll implement the rest of the NEC. This

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

ETZGAR CONVEYOR COMPANY Controls Section v12.05

ETZGAR CONVEYOR COMPANY Controls Section v12.05 Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal

More information

End of Life: 1494V Variable-depth Disconnect Switch (30 100 A) End of Life: 1494C Cable-operated. Product Lifecycle

End of Life: 1494V Variable-depth Disconnect Switch (30 100 A) End of Life: 1494C Cable-operated. Product Lifecycle Migration Solutions 1494V Rod-operated and 1494C Cable-operated Disconnect Switches to 1494U Universal Disconnect Switch 1494U Universal Visible-Blade Disconnect Switch Features and Benefits Users who

More information

For Models #6-5001, #6-7501, #10-7501 & #10-12K1

For Models #6-5001, #6-7501, #10-7501 & #10-12K1 EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Pyrotenax SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Contents Introduction This section provides an overview of general circuit design considerations and installation guidelines for a Pyrotenax System

More information

Power Outlet Panels. Product Guide

Power Outlet Panels. Product Guide Product Guide Construction and Recreational Vehicle (RV) Power Outlet Panels Vehicle Power (RV) Power Outlet Panels Power Outlet Panels Construction and RV Power Outlet Panels Product Description...1 Application

More information

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general

More information

Electrical Code Regulation

Electrical Code Regulation Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county

More information

Section 10 Electric Switchboards: 0 Through 600 Volts

Section 10 Electric Switchboards: 0 Through 600 Volts Section 10 Electric Switchboards: 0 Through 600 Volts 10.1. Scope This section provides specific dimensions and details for service and meter equipment that is assembled by the manufacturer in freestanding,

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content

More information

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MICRONOR automation components Product MICRONOR MR221 and MR222 series Heavy Duty Geared Limit Switches are for use in the most demanding industrial

More information

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015 Hubbell Industrial Controls, Inc. Class 58 Drum Controller Catalog & Price List November 205, Replaces Jan 205 Class 58 Drum Controllers start, stop and change the speed and/or rotating direction of reversible

More information

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information