Heinemann GJ1P Series Circuit Breakers

Similar documents
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Circuit Breakers. NRC Series. NRC Series

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

8146/5 Series Breaker Panelboards

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

4 Posiflow Proportional Solenoid Valves

Pressure Switch for gas and air

Reliable on land or sea. UL 1500 Ignition proof. ABYC compliant. High interrupt capacity. Mechanical Products Company

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

AZ420 MINIATURE GENERAL PURPOSE RELAY

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

General Purpose Relays Types K, R, N, and C

Bolted contact switches. Pringle switches

P70, P72, and P170 Series Controls for Dual Pressure Applications

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Secondary Unit Substations

Phone: Fax: Web: info@clrwtr.com

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Power Supplies 3. SDN-P DIN Rail Series

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Tmax MCCBs. Molded case circuit breakers. Tmax

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Mini USB and USB 2.0-IP67 Connector System

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

CONEC SnapLock. 1 Introduction

Cross-beam scanning system to detect slim objects. 100 mm in

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Centro-Matic Automatic Lubrication Systems System Controls

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Solid-State Timer H3G

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Model Number Structure

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Applications. Remote Display Mounting Kits

Rotary Disconnect Switch Specifications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

R.C.C.B. s two-pole LEXIC

PSR The compact range Description

SECTION VARIABLE FREQUENCY DRIVES

HERZ-Thermal Actuators

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

How To Test A Power Distribution Unit

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Mini Power-Zone Unit Substation

Model Number Structure

Vario-Series Accessories

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

Distribution Dry Type Transformers

Miniature Circuit Breakers and Supplementary Protectors

Agilent 4339B/4349B High Resistance Meters

Circuit Breakers. Next Generation of Protection Capabilities

PS6500 Storage Arrays Rack Mount Instructions

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Safety technique. Emergency stop module BO 5988 safemaster

Three Channel Optical Incremental Encoder Modules Technical Data

SPST-NO SPDT DPST-NO DPDT

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

LOW-VOLTAGE CURRENT TRANSFORMERS

EGSTON Standard E2xFxWx 12W

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Manual motor starter MS116

BETA Protecting SITOR Semiconductor Fuses

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

RM4TG20 three-phase network control relay RM4-T - range V

1.44 kw Programmable DC Power Supplies XLN Series

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

AmphenolR. Now you're connected!

A99B Series Temperature Sensors

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Description. Dimensions. Features. precision works better

Plug-in relays Mini ISO relays

Bulletin 1489 Circuit Breakers. Selection Guide

GAE953 Electrical Alarm Unit 19" with Indicator

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Transcription:

Heinemann GJ1P Series Circuit Breakers

HEINEMANN CIRCUIT BREAKERS TABLE OF CONTENTS Page Description..............2 Specifications............2 Approvals...............2 Time Delay Characteristics...3 Dimensions............4-5 How to Order...........6-7 Additional Products.........8 GJ1P Series Circuit Breakers (100-1200 Amperes DC) DESCRIPTION Optional Low-Voltage Shunt for Current Metering Eaton Corporation s Cutler- Hammer series of Heinemann GJ1P breakers offer high quality circuit protection for DC applications from 100 to 1200 Amperes. Their precisely tailored time delays and ability to interrupt high currents makes them ideally suited for critical applications. On overloads exceeding 1000 1400% of rating, there is no intentional time delay and the breaker interrupts currents of as much as 25,000 A at 65V DC. An optional shunt (25 or 50 millivolt full scale) permits metering of current. Since the shunt output is low voltage, light-gauge wiring can be used from shunt to meter. Indication may be displayed in percent, watts, safe/danger or other dial calibrations. In addition, the busbar is available in two versions: Standard Size and Reduced Size. Contact your Eaton Sales Representative for more information. Precision Current Equalization (PCE) Circuit Breakers GJ1P breakers rated 250 to 1200 A are built in parallel construction. Conventional parallel pole breakers can experience uneven current distribution because of variations in internal resistances. This condition can result in nuisance tripping since the higher current in one parallel branch has the same effect as an overload on the sensing element in that branch. Proprietary Precision Current Equalization (PCE) circuit breakers, on the other hand, allow for differences in internal resistances by automatically distributing the current equally through the parallel current sensing elements, minimizing the danger of nuisance tripping. The UL listed series GJ1P (UL489) models are available in a choice of fast, medium or slow response times to accurately match load conditions. They can be ordered in series trip, mid-trip and switch only constructions and are available front- or backmounted, front- or backconnected, with optional auxiliary switches for signaling. HYDRAULIC-MAGNETIC BENEFITS The magnetic/hydraulic load-sensing and time delay mechanisms used in GJ1P breakers are insensitive to changes in ambient or enclosure temperature. Therefore, GJ1P circuit breakers are suited for service conditions encountered in telecommunications, transportation, air conditioning and other outdoor or heatloaded equipment. SPECIFICATIONS Standard Current Ratings: 100, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 A. Standard Maximum Voltages: 160V DC up to 700A 65V DC from 701 to 1200A Breakers will be labeled with standard maximum (UL) voltage unless otherwise specified. Special Current Ratings: Any integral rating between 100 and 1200 A DC. Consult factory for ordering information and metering shunt restrictions. Interrupting Capacities: UL Listed: 10,000 A @ 160V DC 25,000 A @ 65V DC Non-UL: 14,000 A @ 160V DC. Operating Temperature Range: -40 C to +85 C. Approximate Weight: 1-pole (100-225A) 1.13kg (2.5lbs) 2-pole (250-400A) 2.27kg (5lbs) 3-pole (450-700A) 3.40kg (7.5lbs) 4-pole (701-800A) 4.54kg (10lbs) 5-pole (801-1000A) 5.67kg (12.5lbs) 6-pole (1001-1200A) 6.80kg (15lbs) Weight may vary based on shunt and busbar. APPROVALS UL Listing: GJ1P breakers are UL listed per UL489. For CSA certification, consult application engineering. 2 Heinemann is a registered trademark of the Eaton Corporation, Commercial Controls Business Unit.

TIME DELAY CHARACTERISTICS Time delay, in all models, is inversely proportional to the magnitude of the overload, adjusting automatically to limit transient power to the load. On overloads exceeding 1,000 1,400%, the circuit breaker trips without any deliberately imposed delay. Curve 1. Standard time delay is furnished unless another optional delay is specified. It is the preferred characteristic for use where the load is composed of both resistive and inductive components. Curve 2. Medium time delay is for general use in mixed (inductive and resistive) circuits where the breaker rating is matched to the current carrying capacity of the mains. Curve 3. Short time delay permits a very brief delay period before tripping. Curve P. Non-time delay breakers are available for applications which cannot tolerate even brief transient overloads. These breakers have no time delay mechanism other than that imposed by the coil self-inductance and the inertia of the mechanism. Tripping specifications The time delay curves depict breaker response time vs. percent of rated load with no preloading. The function is plotted at an ambient temperature of 77 F (25 C) with the breaker in a vertical or wall-mounted position. Series GJ1P circuit breakers will carry 100% of rated load continuously. Both time delay and non-time delay breakers may trip between 101% and 125% of rated load, and must trip at 125% and above. INSTANT DELAY DC CURVE P DC CURVES 10,000 10,000 1000 1000 Trip Time Seconds 100 10 1.1 Trip Time Seconds 100 10 1.1 Curve 1 Curve 2 Curve 3.01.01.001 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 Current Percent of Ampere Rating 150.001 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 Current Percent of Ampere Rating 150 PERCENT OF RATED CURRENT VS. TRIP DELAY AT 25ºC % (sec) Delay 100% 125% 200% 400% 600% 800% 1000% Delay Max. 1 no trip 1100 150 20 6 1.7.065 Delay Min. 1 no trip 110 22 4 1.1.01.008 Delay Max. 2 no trip 110 15 3.8.28.055 Delay Min. 2 no trip 12 2.5.5.18.01.008 Delay Max. 3 no trip 10.8.19.08.047.038 Delay Min. 3 no trip.44.13.03.015.01.008 3

HEINEMANN CIRCUIT BREAKERS GJ1P Series Circuit Breakers DIMENSIONS APPROXIMATE IN MM (INCHES) DIMENSIONS Dimensions are given here only as a preliminary guide to specifying. Final engineering drawings should be made from the latest Heinemann drawings. Contact Customer Service Center. STANDARD FRONT-CONNECTED CONSTRUCTION Tolerance: ±0.79 (0.031) except where noted. For metric threads, contact Customer Service Center. Width dimensions are as follows: 100 225 38.1 (1.5) 250 400 A 76.2 (3.0) 450 700 A 114.3 (4.5) 701 800A 142.4 (6.0) 801 1000A 190.5 (7.5) 1001 1200A 228.6 (9.0) Panel Mounting Hole Distance for #10-32 LINE 250 400 See Optional Terminal Configuration 37.69 (1.484) 41.27 (1.625) Wire Range #6 to 250 MCM 74.59 (2.938) 76.20 (3.000) 5.53 (0.219) D Type Terminals as Shown 100 22 A 41.27 (1.625) 36.49 (1.437) Wire Range #6 to 250 MCM 0.99 (0.390) 6.35 ± 0.38 (0.250 ± 0.156) 6.35 ± 0.38 (0.250 ± 0.156) 42.84 (1.687) 71.42 (2.812) 263.52 (10.375) 29.36 (1.156) 58.67 (2.313) 28 ±5 32 ±5 7.14 (0.281) ON OFF 4.74 (0.188) 180.97 (7.125) 78.56 (3.094) 59.13 (2.328) 41.27 (1.625) Aux. Terminals, Male Type Molex 02-09-2101, Model 1190-T (See Illustrations for Combinations) Shunt Terminals, Female Type Molex 02-09-1101, Model 1189-T #10-32 Inserts (4 Places) 41.27 (1.625) LOAD 5.53 (0.218) 59.91 (2.359) 75.38 (2.968) Optional Terminal Configurations 32.13 (1.266) 46.40 (1.828) 22.22 (0.875) 28.95 (1.141) 7.92 (0.312) 60.32 (2.375) 225.43 (8.875) Center to Center Fastener Mounted This Side of Bus Plate, Terminals are Back-Connected and Unit is Panel-Mounted. Fastener Mounted This Side of Bus Plate,Terminals are Front-Connected and Unit is Rear-Mounted. 3/8-16UNC -2B (4 per Unit) 4

DIMENSIONS APPROXIMATE IN MM (INCHES) FRONT MOUNTING PANEL AND SUPPORT BRACKET C L C L C L 115.08 (4.531) (3-Pole) C B A 5.94 (0.234) Ref. 71.42 (2.912) 5.15 (0.203) Typ. Dia. 38.1 76.98 (3.031) (1-Pole) 38.1 A B C C L C L C L 3 Pole 2 Pole (2-Pole) 38.88 (1.531) 1 Pole 19.43 (0.765) 59.13 (2.328) 65.02 (2.562) 31.75 (1.250) Min. 41.65 (1.641) Max. 106.75 (4.203) Typ. 7.51 (0.297) 5.15 (0.203) Dia. Typ. 78.96 (3.109) Min. Typ. 7.51 (0.297) 7.51 (0.297) Holes Required When Breaker Is Front-Mounted Mounting kits containing clips, brackets and necessary hardware and instructions are available (consult factory). 009-18234 100 225 A 1.5 (1-pole wide) 009-18235 250 400 A 3 (2-pole wide) 009-18232 450 700 A 4.5 (3-pole wide) For 701-1200A devices, contact your Eaton Sales Representative for mounting kit part numbers. 22.23 (0.875) Min. 321.31 (12.65) Max. 29.36 (1.156) 16.66 (0.656) Typ. 29.36 (1.156) 100 225 A Ratings 48.41 (1.906) 48.41 (1.906) 226 400 A Ratings 67.46 (2.656) 67.46 (2.656) 401 700 150 A Ratings NOTE: Standard size busbar is shown above. For the reduced size busbar, contact your Eaton Sales Representative for mounting dimensions. BACK MOUNTING CIRCUIT BREAKER See Step (2) See Step (5) Back mounting circuit breaker mounting instructions 1. Position circuit breaker to support brackets. 2. Place mounting bracket in recess on front top portion of circuit breaker. 3. Install four (4) #10-32 by 3-1/4" long screws through holes in mounting bracket and support structure. 4. Install lock washer and nut on each of the screws and tighten. 5. Place mounting bracket on front lower portion of circuit breaker. 6. Install two (2) #10-32 by 5/8" screws through holes in mounting bracket and support structure. 7. Repeat step 4. 5

HEINEMANN CIRCUIT BREAKERS GJ1P Series Circuit Breakers HOW TO ORDER Series GJ1P To determine your Complete Catalog Number, you must start with appropriate Series Prefix and add the appropriate Code Letters and/or Numbers as in the example below: Add each appropriate Number or Letter Series Prefix Terminal Location Internal Circuit Metering Shunt GJ1P B 3- P SELECTION TABLE Series Prefix Terminal Location Internal Circuit Metering Shunt Location Code Internal Circuit Code Description Shunt Code Switch (No Coil) 0- GJ1P Back Front B H Series Trip w/spdt Aux. Switch Series Trip Series Trip and Mid-Trip 2-3- 98- No Shunts Metering Shunt Metering Shunt 25mV 50mV P M N Series Trip, Mid-Trip and SPST Alarm Switch 99-1 Multi-pole construction Consult factory. An auxiliary switch, if supplied, will be located in the right pole space. If the auxiliary switch is supplied in a breaker which has a metering shunt, it will be single-pole single throw (SPST). The single-pole double throw (SPDT) auxiliary switch can be supplied only in a breaker without a metering shunt. 2 Cannot be used on breaker containing metering shunt. 3 Only for breakers rated in excess of 250 A. Breakers up to 250 A without metering shunt are available as standard GJ1 type breakers. Please consult Series GJ catalog. 6

Complete Catalog Number: GJ1PB3-PEDU0700-02 Terminal Configuration US/European Approval Standard Current Ratings 1 Trip Curves1 E DU 0700-02 Terminals Market Standard Current Ratings1 Trip Curve1 Description Code Standard Code Ampere Curve Code Solderless Connector Bus Bar Connection D E UL-489 DU 0 1200 (Add 0 before amp rating if less than 1000A. Example: 0700) 1 2 3 P -01-02 -03-0P 4 Add 0 before amp rating if less than 1000. For example: a 700A rating would be designated as 0700. The width of the breaker is determined by the current rating: 100 225 A 1.5 (1-pole wide) 250 400 A 3 (2-pole wide) 450 700 A 4.5 (3-pole wide) 701 800A 6 (4-pole wide) 801 1000A 7.5 (5-pole wide) 1001 1200A 9 (6-pole wide) 5 See page 3 for time delay characteristics and trip curve information. 7

For the Widest Selection of Circuit Protection, from 0.01 to 1200 Amperes, Look to Eaton. CIRCUIT BREAKER SELECTION GUIDE 100'000 A 10'000 A 1'000 A 100 A 10 A 1 A KD1 PS1 JS AM/R C GH GJ GJ1P Ampere Rating (A) Interrupting Capacity (A) Eaton Corporation Cutler-Hammer Group Commercial Controls Group 4201 N. 27th Street Milwaukee, WI 53216 Americas Customer Service Phone: (800) 962-0820; Phone: (414) 449-6207 Fax: (414) 449-6118 Eaton SA Commercial Controls Group CH-1345 Le Lieu, Switzerland Tel: + 41 21 841 9211; Fax: + 41 21 841 9200 Europe and Far East Customer Service Tel: + 41 21 841 9211; Fax: + 41 21 841 9200 Eaton Corporation Commercial Controls Group 4201 N. 27th Street Milwaukee, WI 53216 Customer Service Center Phone: (800)962-0820 or (414) 449-6207 Fax: (414)449-6760 www.commercialcontrols.eaton.com Commercial Controls 2001 Eaton Corporation All Rights Reserved Printed in USA Form No. BR5401SE0002A / CSS 65322 June 2001