ork etail System Specific iring Diagrams January 2012 Using Honeywell hermostats
Index for Low Voltage iring Affinity Units utdoor Indoor System Description Page ZH 2 Stage HP AV or MV Variable Speed Air Handler - Honeywell VP 8000 D1 ZH 2 Stage HP AV or MV Variable Speed Air Handler - Honeywell VP 9000 D2 ZH 2 Stage HP P9 95% Modulating VS as Furnace - Honeywell VP 8000 D3 ZH 2 Stage HP P9 95% Modulating VS as Furnace - Honeywell VP 9000 D4 ZH 2 Stage HP M9X or 8X 95% & 80% 1 Stage Multi-ap as Furnace H VP 8000 D5 ZH 2 Stage HP M9X & 8X 95% & 80% 1 Stage Multi-ap as Furnace H VP 9000 D6 ZF 1.5-4 on 1 Stage HP AV or MV Variable Speed Air Handler Honeywell VP 8000 D7 ZF 1.5-4 on 1 Stage HP AV or MV Variable Speed Air Handler Honeywell VP 9000 D8 ZF 1.5-4 on 1 Stage HP AHE Variable Speed Air Handler X13 Motor Honeywell VP 8000 D9 ZF 1.5-4 on 1 Stage HP MX Variable Speed Air Handler X13 Motor Honeywell VP 8000 D10 ZF 1.5-4 on 1 Stage HP M9V or 8V 95% & 80% 2 Stage Variable Speed as Furnace H VP 8000 D11 ZF 5-on 2 Stage HP AV or MV Variable Speed Air Handler Honeywell VP 8000 D12 ZF 5-on 2 Stage HP AV or MV Variable Speed Air Handler Honeywell VP 9000 D13 ZF 5-on 2 Stage HP AHE Variable Speed Air Handler X13 Motor Honeywell VP 8000 D14 ZF 5-on 2 Stage HP MX Variable Speed Air Handler X13 Motor Honeywell VP 8000 D15 ZF 5 on 2 Stage HP M9V or 8V 95% & 80% 2 Stage Variable Speed as Furnace H VP 8000 D16 ZF 1.5-4 on 1 Stage HP M9X or 8X 95% & 80%Single Stage X13 as Furnace H VP 8000 D17 ZF 1.5-4 on 1 Stage HP M9X & 8X 95% & 80% Single Stage X13 as Furnace H VP 9000 D18 ZF 5- on 2 Stage HP M9X or 8X 95% & 80%Single Stage X13 as Furnace H VP 8000 D19 ZF 5 on 2 Stage HP M9X & 8X 95% & 80% Single Stage X13 as Furnace H VP 9000 D20 ZF 1.5-4 on 1 Stage HP 9S or 8S 95% & 80% 1 Stage Multi-ap as Furnace H FP 5000 D21 ZF 1.5-4 on 1 Stage HP 9S or 8S 95% & 80% 1Stage Multi-ap as Furnace H VP 8000 D22 ZH 2 Stage A AV or MV Variable Speed Air Handler Honeywell VP8000 D23 ZH 2 Stage A AV or MV Variable Speed Air Handler Honeywell VP9000 D24 ZH 2 Stage A P9 95% Modulating Variable Speed as Furnace H VP8000 D25 ZH 2 Stage A P9 95% Modulating Variable Speed as Furnace H VP9000 D26 ZH 2 Stage A M9V or 8V 95% & 80% 2 Stage Variable Speed as Furnace H VP 8000 D27 ZH 2 Stage A M9V or 8V 95% & 80% 2 Stage Variable Speed as Furnace H VP 9000 D28 ZH 2 Stage A M9X or 8X 95% & 80%Single Stage X13 as Furnace H VP 8000 D29 ZH 2 Stage A 9S or 8S 95% & 80%Single Stage X13 as Furnace H VP 8000 D30 ZF 1 Stage A AV or MV Variable Speed Air Handler Honeywell VP 8000 D31 ZF 1 Stage A AV or MV Variable Speed Air Handler Honeywell VP 9000 D32 ZF 1 Stage A AHE Variable Speed Air Handler X13 Motor Honeywell VP 8000 D33 ZF 1 Stage A MX Variable Speed Air Handler X13 Motor Honeywell VP 8000 D34 ZF 1 Stage A M9V or 8V 95% & 80% 2 Stage Variable Speed as Furnace H VP 8000 D35 ZF 1 Stage A M9V or 8V 95% & 80% 2 Stage Variable Speed as Furnace H VP 9000 D36 ZF 1 Stage A M9X or 8X 95% & 80% 1Stage Multi-ap as Furnace H VP 8000 D37 ZF 1 Stage A 9S or 8S 95% & 80% 1Stage Multi-ap as Furnace H VP 8000 D38 ZF 1 Stage A 9S or 8S 95% & 80% 1 Stage Multi-ap as Furnace H VP 9000 D39 HNEL ZNIN NLS o be determined
Index for Low Voltage iring LX Units HJF 1.5-4 on 1 Stage HP AHE Variable Speed Air Handler X13 Motor Honeywell VP 8000 D40 HJF 1.5-4 on 1 Stage HP MX Variable Speed Air Handler X13 Motor Honeywell VP 8000 D41 HJF 1.5-4 on 1 Stage HP M9V or 8V 95% & 80% 2 Stage Variable Speed as Furnace H VP 8000 D42 HJF 1.5-4 on 1 Stage HP M9X or 8X 95% & 80% 1 Stage Multi-ap as Furnace H VP 8000 D43 HJF 5 on 2 Stage HP M9V or 8V 95% & 80% 2 Stage Variable Speed as Furnace H VP 8000 D44 HJF 5 on 2 Stage HP M9X or 8X 95% & 80% 1 Stage Multi-ap as Furnace H VP 8000 D45 HJD 1 Stage HP AHE Variable Speed Air Handler X13 Motor Honeywell VP 8000 D46 HJD 1 Stage HP MX Variable Speed Air Handler X13 Motor Honeywell VP 8000 D47 HJD 1 Stage HP M9X or 8X 95% & 80% 1 Stage Multi-ap as Furnace H VP 8000 D48 HJ 1 Stage HP 9S or 8S 95% & 80% 1 Stage Multi-ap as Furnace H VP 8000 D49 JF 1 Stage A M9X or 8X 95% & 80% 1 Stage Multi-ap as Furnace H VP 8000 D50 JD 1 Stage A M9X or 8X 95% & 80% 1 Stage Multi-ap as Furnace H VP 8000 D51 A Brief Description of Low Voltage erminals used on ork units. - Hot side of 24 volt transformer - ommon side of 24 volt transformer - ooling or heating call on single stage units - 1st stage cooling or heating call - 2nd stage cooling or heating call / - Used to get full indoor unit FM - Heating call on single stage furnaces - Energize the reversing valve to get cooling - Energize the blower 1-1st stage heating call 2-2nd stage heating call ut - Used to energize the indoor cfm to high speed 1 ut - utput to energize 1st stage heat when in defrost 2 ut - utput to energize 2nd stage heat when in defrost 1/66 - Used to energize 1st stage heat when in defrost BS & BS - erminals on the defrost control to connect bonnet sensor in the duel fuel mode Hum - Humidistat input DHUM - Used to slow the indoor blower in high humidity applications Lo omp - Used on modulating furnaces when there is a single stage thermostat for cooling Hi omp - Used on modulating furnaces when there is a single stage thermostat for cooling
iring Diagram ZH AV MV 2-SAE HEA PUMP SINLE PIEE VAIABLE SPEED AI HANDLE PIEE VAIABLE SPEED AI HANDLE H8321U1006 VAIABLE SPEED AI HANDLE HEA PUMP NL ptional BLU/ Aux H L ptional PU ED BS HUM BS Indoor/utdoor ptional Sensor BLU / U 2 2 U E 1 BN 1 U N NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat 0170 = 12 (ells the stat its operating 3 heat and 2 cool stages) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 1
iring Diagrams ZH 2-SAE HEA PUMP AV SINLE PIEE VAIABLE SPEED AI HANDLE MV PIEE VAIABLE SPEED AI HANDLE HNEL 9000 IAQ HEMSA H E M S A IAQ 9000 VAIABLE SPEED HEA PUMP H94211002 AI HANDLE NL 1 2 3 BLU/ AUX H L PU ED BS H HUM BS / BLU U 2 2 U Aux 2 1 BN 1 U N NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat #172, HANE 2 (tells stat the system in a Heat Pump) #174, HANE 2 (tells stat number of cooling stages) #176, HANE 3 (tells stat number of heating stages) #200, HANE 0 (tells stat back up heat is electric) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 2
iring Diagrams ZH P9 2-SAE HEA PUMP 95% MDULAIN VAIABLE SPEED AS FUNAE H8321U1006 VAIABLE SPEED AS FUNAE HEA PUMP NL ptional BLU/ Aux H L ptional PU ED Lo omp BS HI omp BS Indoor/utdoor ptional Sensor BLU / U Dhum 2 U E BN 1 U N IND A- IL * * PINAL BNNE SENS NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat 0170 = 12 (ells the stat system is 3 heat stages and 2 cool stages 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers J19 Zone ontrol= /N(optional) J22 Heat Pump = ES Set Blower Speeds as equired for Proper FM. J9 = ool, J16 = Adj, J15 = Delay ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default F Fuel = N BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 3
H E M S A IAQ 9000 H94211002 1 2 3 ork System iring Diagrams ZH 2-SAE HEA PUMP P9 95% MDULAIN VAIABLE SPEED AS FUNAE Honeywell 9000 IAQ hermostat VAIABLE SPEED AS FUNAE HEA PUMP NL ptional BLU/ Aux H L ptional PU ED Lo omp BS HI omp BS / BLU U Dhum 2 U E BN 1 U N IND A-IL * * PINAL BNNE SENS NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat #172, HANE 2 (tells stat the system in a Heat Pump) #174, HANE 2 (tells stat number of cooling stages) #176, HANE 3 (tells stat number of heating stages) #200, HANE 1 (tells stat back up heat is electric) #210, HANE 1 (tells stat external fossil fuel kit) ritical Installation Set up on Furnace Jumpers J9=Zone ontrol = /N (optional) J22=Heat Pump = ES Set Blower Speeds as equired for Proper FM. J9 = ool, J16 = Adj, J15 = Delay ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default F Fuel = N BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 4
iring Diagrams ZH M9X M8X 2-SAE HEA PUMP as Furnace as Furnace H8321U1006 M9X as Furnace HEA PUMP NL BLU/ AUX H PU - ptional L ED BS Indoor/utdoor ptional Sensor BLU / U 2 U E BN 1 U N BS IND A-IL * PINAL BNNE SENS NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat 0170 = 12 (ells the stat system is 3 heat stages and 2 cool stages 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers P4 Jumper = Blower ff Delay P7 Jumper = Fan Speed ontionus Fan Set motor speeds as required for proper air flow ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 5
iring Disgrams ZH 2-SAE HEA PUMP M9X as Furnace M8X as Furnace HNEL 9000 IAQ HEMSA H E M S A IAQ 9000 H94211002 1 2 3 BLU/ AUX H PU - ptional L ED H M9X as Furnace / HEA PUMP NL U 2 U Aux 2 BN 1 U N NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. BLU BS BS IND A-IL Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat #172, HANE 2 (tells stat the system in a Heat Pump) #174, HANE 2 (tells stat number of cooling stages) #176, HANE 3 (tells stat number of heating stages) #200, HANE 1 (tells stat back up heat is fossil fuel) #210, HANE 1 (tells stat fossil fuel is controlled external) ritical Installation Set up for Furnace Jumpers P4 Jumper = Blower ff Delay P7 Jumper = Fan Speed ontionus Fan Set motor speeds as required for proper air flow ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 6
iring Diagrams ZF AV MV 1-SAE HEA PUMP - 1.5-4 on SINLE PIEE VAIABLE SPEED AI HANDLE PIEE VAIABLE SPEED AI HANDLE H8321U1006 VAIABLE SPEED AI HANDLE HEA PUMP NL ptional Aux H L ptional PU ED BS HUM BS Indoor/utdoor ptional Sensor BLU / U 2 2 U E 1 BN 1 U N NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat 0170 = 7 (tells the stat it's operating at 2 heat and 1 cool stage as a heat pump) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 7
iring Diagrams ZF!-SAE HEA PUMP 1.5-4 on AV SINLE PIEE VAIABLE SPEED AI HANDLE MV PIEE VAIABLE SPEED AI HANDLE HNEL 9000 IAQ HEMSA H E M S A IAQ 9000 VAIABLE SPEED HEA PUMP H94211002 AI HANDLE NL 1 2 3 BLU/ AUX H L PU ED BS H HUM BS / BLU U 2 2 U Aux 2 1 BN 1 U N NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat #172, HANE 2 (tells stat the system in a Heat Pump) #174, HANE 1 (tells stat number of cooling stages) #176, HANE 2 (tells stat number of heating stages) #200, HANE 0 (tells stat back up heat is electric) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 8
iring Diagrams ZF AHE 1-SAE HEA PUMP - 1.5-4 on SINLE PIEE X13 AI HANDLE H8321U1006 X13 MULI -AP AI HANDLE HEA PUMP NL ptional Aux H L ptional PU ED BS Indoor/utdoor ptional Sensor BS U 2 2 U E 1 BN 1 U N ritical Installation Set up on hermostat 0170 = 7 (tells the stat it's operating at 2 heat and 1 cool stage as a heat pump) ritical Installation Set up for Air Handler Jumpers Set Blower Speeds as equired for Proper FM Note: 2 only required if 13 K and above. ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = FF Lock = N/FF (ptional as a consumer choice) BP (balance point) = 35º is factory setting, but can be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 9
iring Diagrams ZF MX 1-SAE HEA PUMP - 1.5-4 on PIEE X13 AI HANDLE H8321U1006 X13 MULI -AP AI HANDLE HEA PUMP NL ptional / Aux H L ptional PU ED BS Indoor/utdoor ptional Sensor HUM BS U 2 2 U E 1 BN 1 U N ritical Installation Set up on hermostat 0170 = 7 (tells the stat it's operating at 2 heat and 1 cool stage as a heat pump) 0180 = 1 (Fan is controlled by thermostat) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = FF Lock = N/FF (ptional as a consumer choice) BP (balance point) = 35º is factory setting, but can be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 10
iring Diagrams ZF M9V M8V 1-SAE HEA PUMP - 1.5-4 on 95% 2 Stage Variable Speed as Furnace 80% 2 Stage Vairable Speedas Furnace Variable Speed HEA PUMP AS FUNAE NL H8321U1006 ptional BLU/ Aux H L ptional XL PU ED BS BS Indoor/utdoor ptional Sensor BLU / U 2 2 U E BN 1 U N IND A-IL * * PINAL BNNE SENS NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat 0170 = 7 (ells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers Heat Pump = Set Blower Speeds as equired for Proper FM. Heat, ool, Delay, Adjust Set Staging Jumper for 10,15,or 20 minutes ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default F Fuel = N BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 11
iring Diagrams ZF AV MV 2-SAE HEA PUMP 5 N NL SINLE PIEE VAIABLE SPEED AI HANDLE PIEE VAIABLE SPEED AI HANDLE H8321U1006 VAIABLE SPEED AI HANDLE HEA PUMP NL ptional BLU/ Aux H L ptional PU ED BS HUM BS Indoor/utdoor ptional Sensor BLU / U 2 2 U E 1 BN 1 U N NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat 0170 = 12 (ells the stat its operating 3 heat and 2 cool stages) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 12
iring Diagrams ZF 2-SAE HEA PUMP 5 N NL AV SINLE PIEE VAIABLE SPEED AI HANDLE MV PIEE VAIABLE SPEED AI HANDLE HNEL 9000 IAQ HEMSA H E M S A IAQ 9000 VAIABLE SPEED HEA PUMP H94211002 AI HANDLE NL 1 2 3 BLU/ AUX H L PU ED BS H HUM BS / BLU U 2 2 U Aux 2 1 BN 1 U N NES: If 10-wires between the Air Handler and the Heat Pump is not possible 1 and 2 can be combined at the AH with a jumper eliminating 2 out and staged electric heat. can be eliminated as the fault codes can be retrived from the board. Please call for more detailed instructions if the number of wires is an issue. ritical Installation Set up on hermostat #172, HANE 2 (tells stat the system in a Heat Pump) #174, HANE 2 (tells stat number of cooling stages) #176, HANE 3 (tells stat number of heating stages) #200, HANE 0 (tells stat back up heat is electric) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 13
iring Diagrams ZF AHE 2-SAE HEA PUMP - 5 on nly SINLE PIEE X13 AI HANDLE H8321U1006 X13 MULI -AP AI HANDLE HEA PUMP NL ptional Aux H L ptional PU ED BS BS Indoor/utdoor ptional Sensor o Motor Speed U 2 2 U E 1 BN 1 U N ritical Installation Set up on hermostat 0170 = 12 (tells the stat it's operating at 3 heat and 2 cool stage as a heat pump) ritical Installation Set up for Air Handler Jumpers Set Blower Speeds as equired for Proper FM Note: 2 only required if 13 K and above. ut must be connected to the X13 motor Speed to deliver 400cfm per ton. ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = FF Lock = N/FF (ptional as a consumer choice) BP (balance point) = 35º is factory setting, but can be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 14
iring Diagrams ZF MX 1-SAE HEA PUMP - 5 on nly PIEE X13 AI HANDLE H8321U1006 X13 MULI -AP AI HANDLE HEA PUMP NL ptional BLU/ / Aux H L ptional PU ED BS Indoor/utdoor ptional Sensor HUM BS U 2 2 U E 1 BN 1 U N ritical Installation Set up on hermostat 0170 = 12 (tells the stat it's operating at 3 heat and 2 cool stage as a heat pump) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = FF Lock = N/FF (ptional as a consumer choice) BP (balance point) = 35º is factory setting, but can be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 15
iring Diagrams ZF M9V M8V 2-SAE HEA PUMP - 5 on nly 95% 2 Stage Variable Speed as Furnace 80% 2 Stage Vairable Speedas Furnace Variable Speed HEA PUMP AS FUNAE NL H8321U1006 ptional / Aux H L ptional XL PU ED BS Indoor/utdoor ptional Sensor Dhum BS U 2 2 U E 1 BN 1 U IND A-IL * * PINAL BNNE SENS ritical Installation Set up on hermostat 0170 = 12 (ells the stat iis operating at 3 heat and 2 cool stage as a heat pump) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers Heat Pump = Set Blower Speeds as equired for Proper FM. Heat, ool, Delay, Adjust Set Staging Jumper for 10,15,or 20 minutes ritical Installation Set up for Heat Pump Jumpers F Fuel (Fossil Fuel) = N (Factory Default is off, however it MUS be changed to N) BP (balance point) = 35º is factory setting, but should be set to job specific temperature ompressor Delay = hange to on for delay when going into and out of defrost D 16
iring Diagrams ZF M9X M8X 1-SAE HEA PUMP 1.5-4 on as Furnace as Furnace H8321U1006 M9X as Furnace HEA PUMP NL / AUX H PU - ptional L ED Indoor/utdoor ptional Sensor BS BS U 2 U E BN 1 U N IND A-IL * PINAL BNNE SENS ritical Installation Set up on hermostat 0170 = 7 (ells the stat system is 2 heat stages and 1 cool stages 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers P4 Jumper = Blower ff Delay P7 Jumper = Fan Speed ontionus Fan Set motor speeds as required for proper air flow ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 17
iring Diagrams ZF 1-SAE HEA PUMP 1.5-4 on M9X as Furnace M8X as Furnace HNEL 9000 IAQ HEMSA H E M S A IAQ 9000 H94211002 M9X as Furnace HEA PUMP NL 1 2 3 / AUX H PU - ptional L ED BS H BS U 2 U Aux 2 BN 1 U N IND A-IL ritical Installation Set up on hermostat #172, HANE 2 (tells stat the system in a Heat Pump) #174, HANE 1 (tells stat number of cooling stages) #176, HANE 2 (tells stat number of heating stages) #200, HANE 1 (tells stat back up heat is fossil fuel) #210, HANE 1 (tells stat fossil fuel is controlled external) ritical Installation Set up for Furnace Jumpers P4 Jumper = Blower ff Delay P7 Jumper = Fan Speed ontionus Fan Set motor speeds as required for proper air flow ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 18
iring Diagrams ZF M9X M8X 2-SAE HEA PUMP 5 - on nly as Furnace as Furnace H8321U1006 M9X as Furnace HEA PUMP NL / AUX H PU - ptional L ED Indoor/utdoor ptional Sensor BLU/ 2 U E BN 1 U N BS BS U IND A-IL * PINAL BNNE SENS ritical Installation Set up on hermostat 0170 = 12 (ells the stat system is 3 heat stages and 2 cool stages 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers P4 Jumper = Blower ff Delay P7 Jumper = Fan Speed ontionus Fan Set motor speeds as required for proper air flow ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 19
iring Diagram ZF 2-SAE HEA PUMP 5 - on nly M9X as Furnace M8X as Furnace HNEL 9000 IAQ HEMSA H E M S A IAQ 9000 H94211002 M9X as Furnace HEA PUMP NL 1 2 3 BLU/ / AUX H PU - ptional L ED BS H BS U 2 U Aux 2 BN 1 U N IND A-IL ritical Installation Set up on hermostat #172, HANE 2 (tells stat the system in a Heat Pump) #174, HANE 2 (tells stat number of cooling stages) #176, HANE 3 (tells stat number of heating stages) #200, HANE 1 (tells stat back up heat is fossil fuel) #210, HANE 1 (tells stat fossil fuel is controlled external) ritical Installation Set up for Furnace Jumpers P4 Jumper = Blower ff Delay P7 Jumper = Fan Speed ontionus Fan Set motor speeds as required for proper air flow ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (optional) Lock = N/FF (ptional) Switch Point = 35º is Factory Default BP (balance point) = 35º is factory setting, but should be set to job specific temperature L (Low emperature ut ut) = N is factory Setting, this does not have to move unless required ompressor Delay = hange to on for delay when going into and out of defrost D 20
iring Diagrams ZF 1-SAE HEA PUMP - 1.5-4 on 9S 90% MULI-AP AS FUNAE 8S 80% MULI-AP AS FUNAE Focus Pro 5000 SINLE SPEED MULI-AP HEA PUMP H5220D1003 AS FUNAE NL ptional / AUX H L ptional PU ED BS BS U 2 U E BN 1 U IND A-IL * * PINAL BNNE SENS * PINAL BNNE SENS ritical Installation Set up on hermostat 1 = 5 (ells the stat 2 heat stages and 1 cool stage) 6 = 5-80% Furnace 3-90% or Better (ells stat furnace efficiency for cycle rates) 8 = 5-80% Furnace 3-90% or Better (ells stat furnace efficiency for Emergency cycle rates) ritical Installation Set up on Furnace Jumpers Set Blower Speeds as equired for Proper FM ritical Installation Set up for Heat Pump Jumpers F Fuel (Fossil Fuel) = N (Factory Default is off, however it MUS be changed to N) BP (balance point) = 35º is factory setting, but should be set to job specific temperature ompressor Delay = hange to on for delay when going into and out of defrost D 21
iring Diagram ZF 1-SAE HEA PUMP - 1.5-4 on 9S 95% Single Stage PS as Furnace 8S 80% Single Stage PS as Furnace Milti Speed HEA PUMP H8321U1006 AS FUNAE NL ptional / Aux H L ptional PU ED BS Indoor/utdoor ptional Sensor DHUM BS Lo omp U Hi omp 2 U E BN 1 U N IND A-IL * * PINAL BNNE SENS ritical Installation Set up on hermostat 0170 = 7 (ells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers Set Blower Speeds as equired for Proper FM ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (Factory Default is FF, however we recommend it be changed to N) Lock = N/FF (Factory Default is FF, however we recommend it be changed to N) Switch Point = 35º is Factory Default, change if needed F Fuel (Fossil Fuel) = N (Factory Default is off, however it MUS be changed to N) BP (balance point) = 35º is factory setting, but should be set to job specific temperature D 22
iring Diagrams ZH AV MV 2-SAE AI NDIINE SINLE PIEE VAIABLE SPEED AHU PIEE VAIABLE SPEED AHU H8321U1006 VAIABLE SPEED AI HANDLE 2 SAE A/ NL ptional / BLU/ 1 2 2 ED Indoor/utdoor ptional Sensor HUM ritical Installation Set up on hermostat 0170 = 8 (tells stat 2 heat stages and 2 cooling stages) 0180= 1 (tells stat system is using electric furnace) 0240= 9 ( tells stat 1st stage heating cycle rate) 0250= 9 (tells stat 2nd stage heating cycle rate) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat P6 Jumper = Heat Pump Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Air onditioning Jumpers Lock = N/FF (ptional) D 23
iring Diagrams ZH AV MV 2-SAE AI NDIINE SINLE PIEE VAIABLE SPEED AHU PIEE VAIABLE SPEED AHU H E M S A IAQ 9000 VAIABLE SPEED 2 SAE A/ H94211002 AI HANDLE NL 1 2 3 ptional / BLU/ AUX 1 L ED H HUM AUX2 2 ritical Installation Set up on hermostat 0172 = 1 (tells stat onventional System) 0174= 2 (tells stat number of cooling stages) 0176= 2 ( tells stat # of heating stages) 0180= 2 (tells stat equipment controls fan) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Air onditioning Jumpers Lock = N/FF (ptional) D 24
iring Diagram ZH P9 2-SAE AI NDIINE 95% MDULAIN VAIABLE SPEED AS FUNAE H8321U1006 MDULAIN AS FUNAE 2 SAE A/ NL ptional / BLU/ 2 ED Lo omp Indoor/utdoor ptional Sensor HI omp Dhum N ritical Installation Set up on hermostat 0170 = 10 (tells stat 1 heat stage and 2 cooling stages) 0240= 3 (tells stat 1st stage heaing cycle rate) ritical Installation Set Up on Furnace 1. If zoning is applied, set the "Zone ontrol" jumper to ES which eliminates the UN 2 cycle of the furnace which normally begins when the call from the thermostat ends. 2. Set Blower Speeds as equired for Proper FM D 25
iring Diagram ZH P9 2-SAE AI NDIINE 95% MDULAIN VAIABLE SPEED AS FUNAE H E M S A IAQ 9000 MDULAIN 2 SAE A/ H94211002 AS FUNAE NL 1 2 3 ptional / BLU/ 2 ED Lo omp Indoor/utdoor ptional Sensor HI omp Dhum N ritical Installation Set up on hermostat 0172 = 1 (tells stat onventional System) 0174= 2 (tells stat number of cooling stages) 0176= 1 ( tells stat # of heating stages) 0180= 0 (tells stat equipment controls fan) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM. J9 = ool, J16 = Adj, J15 = Delay D 26
iring Diagrams ZH M9V M8V 2-SAE AI NDIINE 95% 2 Stage Variable Speed as Furnace 80% 2 Stage Vairable Speed as Furnace H8321U1006 2 Stage AS FUNAE 2 SAE A/ NL ptional / BLU/ 1 2 2 ED Indoor/utdoor ptional Sensor Dhum N ritical Installation Set up on hermostat 0170 = 8 (tells stat 2 heat stage and 2 cooling stages) 0240= 3-90% Furnace 5-80% Furnace (tells stat 1st stage heaing cycle rate) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM D 27
iring Diagrams ZH M9V M8V 2-SAE AI NDIINE 95% 2 Stage Variable Speed as Furnace 80% 2 Stage Vairable Speed as Furnace H E M S A IAQ 9000 2 Stage 2 SAE A/ H94211002 AS FUNAE NL 1 2 3 ptional / BLU/ 1 2 2 ED Indoor/utdoor ptional Sensor Dhum N ritical Installation Set up on hermostat 0172 = 1 (tells stat onventional System) 0174= 2 (tells stat number of cooling stages) 0176= 2 ( tells stat # of heating stages) 0180= 0 (tells stat equipment controls fan) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM D 28
iring Diagram ZH M9X M8X 2-SAE AI NDIINE 95% Single Stage X13 as Furnace 80% Single Stage X13 as Furnace H8321U1006 Single Stage AS FUNAE 2 SAE A/ NL ptional / BLU/ 2 ED Indoor/utdoor ptional Sensor N ritical Installation Set up on hermostat 0170 = 10 (tells stat 1 heat stage and 2 cooling stages) 0240= 3-90% Furnace 5-80% Furnace (tells stat 1st stage heaing cycle rate) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM D 29
iring Diagram ZH 2-SAE AI NDIINE - -410a 9S 90% SINLE SAE MULI-AP AS FUNAE 8S 80% SINLE SAE MULI-AP AS FUNAE IL FUNAES - VEIF IH AUAL FUNAE MANUFAUE'S IIN DIAAM Focus Pro 5000 5110D1006 SINLE SPEED MULI-AP AS/IL FUNAE A NL ptional / ED H ritical Installation Set up on hermostat Parameter 5 = 5 for 80% Furnace or 3 for 90% or Better (tells stat cycle rate) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM D 30
iring Diagrams ZF AV MV 1-SAE AI NDIINE - -410a SINLE PIEE VAIABLE SPEED AI HANDLE PIEE VAIABLE SPEED AI HANDLE H8321U1006 VAIABLE SPEED AI NDIINE NL AI HANDLE ptional 2 / 1 2 HUM N ritical Installation Set up on hermostat 0170 = 9 (tells stat 2 heat stage and 1 cooling stages) 0240= 9 (tells stat 1st stage heaing cycle rate) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. ritical Installation Set up for Heat Pump Jumpers Lock = N/FF (ptional) D 31
s iring Diagrams ZF AV MV 1-SAE AI NDIINE - -410a SINLE PIEE VAIABLE SPEED AI HANDLE PIEE VAIABLE SPEED AI HANDLE H E M S A IAQ 9000 H94211002 1 2 3 VAIABLE SPEED AI HANDLE ptional / 1 2 2 HUM AI NDIINE NL N ritical Installation Set up on hermostat 0172 = 1 (tells stat onventional System) 0174= 1 (tells stat number of cooling stages) 0176= 2 ( tells stat # of heating stages) 0180= 2 (tells stat equipment controls fan) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat Set Blower Speeds as equired for Proper FM. P9 = Heat,P10 = Delay,P8 = ool,p11 = Adj. D 32
iring Diagrams ZF AHE 1-SAE AI NDIINE SINLE PIEE X13 AI HANDLE H8321U1006 X13 MULI -AP AI HANDLE AI NDIINE NL ptional 2 Indoor/utdoor ptional Sensor N 2 1 ritical Installation Set up on hermostat 0170 = 9 (tells the stat it's operating at 2 heat and 1 cool stage onventional) ritical Installation Set up for Air Handler Jumpers Set Blower Speeds as equired for Proper FM Note: 2 only required if 13 K and above. D 33
iring Diagrams ZF MX 1-SAE AI NDIINEE PIEE X13 AI HANDLE H8321U1006 X13 MULI -AP AI HANDLE AI NDIINE NL ptional / 2 1 Indoor/utdoor ptional Sensor N HUM 2 1 ritical Installation Set up on hermostat 0170 = 9 (tells the stat it's operating at 2 heat and 1 cool stage onventional) ritical Installation Set up for Air Handler Jumpers P5 Jumper = Heat Set Blower Speeds as equired for Proper FM D 34
iring Diagram ZF M9V M8V 1-SAE AI NDIINEE 95% 2 Stage Variable Speed as Furnace 80% 2 Stage Vairable Speedas Furnace Variable Speed AI NDIINE AS FUNAE NL H8321U1006 ptional / L 2 1 Indoor/utdoor ptional Sensor N 2 ritical Installation Set up on hermostat 0170 = 9 (ells the stat iis operating at 2 heat and 1 cool onventional) 0240= 3-90% Furnace 5-80% Furnace (tells stat 1st stage heaing cycle rate) ritical Installation Set up on Furnace Jumpers Set Blower Speeds as equired for Proper FM. Heat, ool, Delay, Adjust D 35
iring Diagrams ZF M9V M8V 1-SAE AI NDIINEE 95% 2 Stage Variable Speed as Furnace 80% 2 Stage Vairable Speedas Furnace H E M S A IAQ 9000 Variable Speed AI NDIINE AS FUNAE NL H94211002 1 2 3 ptional / Aux L Indoor/utdoor ptional Sensor 2 2 1 N ritical Installation Set up on hermostat 0172 = 1 (tells stat onventional System) 0174= 1 (tells stat number of cooling stages) 0176= 2 ( tells stat # of heating stages) 0180= 0 (tells stat equipment controls fan) ritical Installation Set up on Furnace Jumpers Set Blower Speeds as equired for Proper FM. Heat, ool, Delay, Adjust D 36
iring Diagrams ZF M9X M8X 1-SAE AI NDIINE 95% Single Stage X13 as Furnace 80% Single Stage X13 as Furnace H8321U1006 Single Stage AS FUNAE 2 SAE A/ NL ptional / 2 ED Indoor/utdoor ptional Sensor N ritical Installation Set up on hermostat 0170 = 1 (tells stat 1 heat stage and 1 cooling stages) 0240= 3-90% Furnace 5-80% Furnace (tells stat 1st stage heaing cycle rate) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM D 37
iring Diagrams ZF 1-SAE AI NDIINE - -410a 9S 90% SINLE SAE MULI-AP AS FUNAE 8S 80% SINLE SAE MULI-AP AS FUNAE IL FUNAES - VEIF IH AUAL FUNAE MANUFAUE'S IIN DIAAM H8321U1006 SINLE SPEED MULI-AP AS/IL FUNAE A NL ptional / L 2 1 ED H ritical Installation Set up on hermostat 0170 = 9 (ells the stat iis operating at 2 heat and 1 cool onventional) 0240= 3-90% Furnace 5-80% Furnace (tells stat 1st stage heaing cycle rate) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM D 38
iring Diagrams ZF 1-SAE AI NDIINE - -410a 9S 90% SINLE SAE MULI-AP AS FUNAE 8S 80% SINLE SAE MULI-AP AS FUNAE IL FUNAES - VEIF IH AUAL FUNAE MANUFAUE'S IIN DIAAM H E M S A IAQ 9000 H94211002 1 2 3 ptional SINLE SPEED MULI-AP AS/IL FUNAE / A NL L ED 2 1 H ritical Installation Set up on hermostat 0172 = 1 (tells stat onventional System) 0174= 1 (tells stat number of cooling stages) 0176= 1 ( tells stat # of heating stages) 0180= 0 (tells stat equipment controls fan) ritical Installation Set up on Furnace Jumpers Set Blower Speeds as equired for Proper FM D 39
ork Syste iring Diagrams HJF AHE 1-SAE HEA PUMP - 1.5-4 on SINLE PIEE X13 AI HANDLE H8321U1006 X13 MULI -AP AI HANDLE HEA PUMP NL ptional Aux H L ptional PU ED Indoor/utdoor ptional Sensor 2 E 1 BN 1/66 N ritical Installation Set up on hermostat 0170 = 7 (tells the stat it's operating at 2 heat and 1 cool stage as a heat pump) ritical Installation Set up for Air Handler Jumpers Set Blower Speeds as equired for Proper FM Note: 2 only required if 13 K and above. ritical Installation Set up for Heat Pump Jumpers Defrost urve = Position 2 D 40
iring Diagrams HJF 1-SAE HEA PUMP - -410a 1.5-4 ons MX Air Handler with X13 Motor HEA PUMP H8321U1006 MX NL ptional / Aux H L ptional XL PU ED Blue utdoorsensor ptional 1 1/66 E N 2 Hum ritical Installation Set up on hermostat 0170 = 7 (ells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0180 = 1 ( Fan is controlled by thermostst) Note: utdoor sensor cable must be separate from the thermostat cable. ritical Installation Set up on Air Handler Set Blower Speeds as equired for Proper FM Heat Enable = es if Electric Heater is installed Hunidistat = Set to yes if Humidistat is present Heat Pump = es ritical Installation Set up for Heat Pump Jumpers Defrost urve Position 2 D 41
iring Diagrams HJF 1-SAE HEA PUMP - -410a 1.5-4 ons M9V 96% 2 SAE AS FUNAE M8V 80% 2 SAE AS FUNAE HEA PUMP H8321U1006 AS FUNAE NL ptional / Aux 1 H 1/66 L ptional XL PU ED utdoorsensor equired # 7089U 2 E N ritical Installation Set up on hermostat 0170 = 7 (ells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 0 (ells stat fossil fuel kit is internal) 0270 = 3 (For 90% Furnace or 5 For 80%) 0340 = 2 (utdoor Sensor ontrol) 0350 = 35 ( Balance Point for Lock ut ange 15 to 45 Degrees) Note: utdoor sensor cable must be separate from the thermostat cable. ritical Installation Set up on Furnace Jumpers ontionus Fan Speed set as equired Set Blower Speeds as equired for Proper FM Fan ff Delay Set as equired High Heat Delay can be set for 10,15,or 20 minutes. Heat Pump = es ritical Installation Set up for Heat Pump Jumpers Defrost urve Position 2 D 42
iring Diagrams HJF 1-SAE HEA PUMP - -410a 1.5-4 ons M9X 95% SINLE SAE AS FUNAE M8X 80% SINLE SAE AS FUNAE HEA PUMP H8321U1006 AS FUNAE NL ptional / Aux H 1/66 L ptional PU ED utdoorsensor equired # 7089U E N ritical Installation Set up on hermostat 0170 = 7 (ells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 0 (ells stat fossil fuel kit is internal) 0270 = 3 (For 90% Furnace or 5 For 80%) 0340 = 2 (utdoor Sensor ontrol) 0350 = 35 ( Balance Point for Lock ut ange 15 to 45 Degrees) Note: utdoor sensor cable must be separate from the thermostat cable. ritical Installation Set up on Furnace Jumpers ontionus Fan Spped set as equired Set Blower Speeds as equired for Proper FM Fan ff Delay Set as equired ritical Installation Set up for Heat Pump Jumpers Defrost urve Position 2 D 43
iring Diagrams HJF 2-SAE HEA PUMP - -410a 5 ons nly M9V 96% 2 SAE AS FUNAE M8V 80% 2 SAE AS FUNAE Vision Pro 8000 HEA PUMP AS FUNAE NL H8321U1006 ptional Blu/el Aux H L ptional PU ED BS Blu BS / U 2 2 U E 1 BN 1 U IND A-IL * * PINAL BNNE SENS * PINAL BNNE SENS ritical Installation Set up on hermostat 0170 = 7 (tells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers ontionus Fan Spped set as equired Set Blower Speeds as equired for Proper FM Fan ff Delay Set as equired High Heat Delay can be set for 10,15,20 minutes. Heat Pump = es ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (Factory Default is FF, but it must be turned N for this application) Lock = N/FF (Factory Default is FF, however we recommend it be changed to N) Switch Point = 35º is Factory Default, change if needed F Fuel (Fossil Fuel) = N (Factory Default is off, however it MUS be changed to N) BP (balance point) = 35º is factory setting, but should be set to job specific temperature D 44
iring Diagrams HJF 2-SAE HEA PUMP - -410a 5 ons nly M9X 95% SINLE SAE AS FUNAE M8X 80% SINLE SAE AS FUNAE Vision Pro 8000 HEA PUMP AS FUNAE NL H8321U1006 ptional Blu/el Aux H L ptional PU ED BS BS Indoor/utdoor optional sensor Blu / U 2 U E BN 1 U IND A-IL * * PINAL BNNE SENS * PINAL BNNE SENS ritical Installation Set up on hermostat 0170 = 7 (tells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 1 (ells stat fossil fuel kit is external) ritical Installation Set up on Furnace Jumpers ontionus Fan Spped set as equired Set Blower Speeds as equired for Proper FM Fan ff Delay Set as equired ritical Installation Set up for Heat Pump Jumpers Hot Heat Pump = N/FF (Factory Default is FF, But it must be turned on for this application) Lock = N/FF (Factory Default is FF) Switch Point = 35º is Factory Default, change if needed F Fuel (Fossil Fuel) = N (Factory Default is off, however it MUS be changed to N) BP (balance point) = 35º is factory setting, but should be set to job specific temperature D 45
iring Diagrams HJD 1-SAE HEA PUMP - AHE SINLE PIEE X13 AI HANDLE H8321U1006 X13 MULI -AP AI HANDLE HEA PUMP NL ptional Aux H L ptional PU ED Indoor/utdoor ptional Sensor 2 E 1 BN 1/66 N ritical Installation Set up on hermostat 0170 = 7 (tells the stat it's operating at 2 heat and 1 cool stage as a heat pump) ritical Installation Set up for Air Handler Jumpers Set Blower Speeds as equired for Proper FM Note: 2 only required if 13 K and above. ritical Installation Set up for Heat Pump Jumpers Defrost ime 30,60,90 Minutes D 46
iring Diagrams HJD 1-SAE HEA PUMP - -410a 1.5-4 ons MX Air Handler with X13 Motor HEA PUMP H8321U1006 AHX NL ptional / Aux H L ptional XL PU ED Blue utdoorsensor ptional 1 1/66 E N 2 Hum ritical Installation Set up on hermostat 0170 = 7 (ells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0180 = 1 ( Fan is controlled by thermostst) Note: utdoor sensor cable must be separate from the thermostat cable. ritical Installation Set up on Air Handler Set Blower Speeds as equired for Proper FM Heat Enable = es if Electric Heater is installed Hunidistat = Set to yes if Humidistat is present Heat Pump = es ritical Installation Set up for Heat Pump Jumpers Defrost ime 30,60,90 Minutes D 47
iring Diagrams HJD 1-SAE HEA PUMP - -410a 1.5-5 ons M9X 95% SINLE SAE AS FUNAE M8X 80% SINLE SAE AS FUNAE HEA PUMP H8321U1006 AS FUNAE NL ptional / Aux H 1/66 L ptional PU ED utdoorsensor equired # 7089U E N ritical Installation Set up on hermostat 0170 = 7 (ells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 0 (ells stat fossil fuel kit is internal) 0270 = 3 (For 90% Furnace or 5 For 80%) 0340 = 2 (utdoor Sensor ontrol) 0350 = 35 ( Balance Point for Lock ut ange 15 to 45 Degrees) Note: utdoor sensor cable must be separate from the thermostat cable. ritical Installation Set up on Furnace Jumpers ontionus Fan Spped set as equired Set Blower Speeds as equired for Proper FM Fan ff Delay Set as equired ritical Installation Set up for Heat Pump Jumpers Defrost ime 30,60,90 Minutes D 48
iring Diagrams HJ 1-SAE HEA PUMP - -410a 1.5-5 ons 9S 95% SINLE SAE AS FUNAE 8S 80% SINLE SAE AS FUNAE HEA PUMP H8321U1006 AS FUNAE NL ptional Aux H 1/66 L ptional PU ED utdoorsensor equired # 7089U E N ritical Installation Set up on hermostat 0170 = 7 (ells the stat iis operating at 2 heat and 1 cool stage as a heat pump) 0190 = 0 ( eversing Valve in Normal Heat Mode) 0200 = 1 (ells stat back up is fossil fuel) 0210 = 0 (ells stat fossil fuel kit is internal) 0270 = 3 (For 90% Furnace or 5 For 80%) 0340 = 2 (utdoor Sensor ontrol) 0350 = 35 ( Balance Point for Lock ut ange 15 to 45 Degrees) Note: utdoor sensor cable must be separate from the thermostat cable. ritical Installation Set up on Furnace Jumpers ontionus Fan Spped set as equired Set Blower Speeds as equired for Proper FM Fan ff Delay Set as equired ritical Installation Set up for Heat Pump Jumpers Defrost ime 30,60,90 Minutes D49
iring Diagrams JF M9X M8X 1-SAE AI NDIINE 95% Single Stage X13 as Furnace 80% Single Stage X13 as Furnace H8321U1006 Single Stage AS FUNAE 2 SAE A/ NL ptional / 2 Indoor/utdoor ptional Sensor N ritical Installation Set up on hermostat 0170 = 1 (tells stat 1 heat stage and 1 cooling stages) 0240= 3-90% Furnace 5-80% Furnace (tells stat 1st stage heaing cycle rate) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM D50
iring Diagrams JD M9X M8X 1-SAE AI NDIINE 95% Single Stage X13 as Furnace 80% Single Stage X13 as Furnace H8321U1006 Single Stage AS FUNAE 2 SAE A/ NL ptional / 2 Indoor/utdoor ptional Sensor N ritical Installation Set up on hermostat 0170 = 1 (tells stat 1 heat stage and 1 cooling stages) 0240= 3-90% Furnace 5-80% Furnace (tells stat 1st stage heaing cycle rate) ritical Installation Set Up on Furnace Set Blower Speeds as equired for Proper FM D 51