APPENDIX / ANHANG / ANNEXE



Similar documents
APPENDIX / ANHANG / ANNEXE ALPHA ALTERNATOR DIMENSIONS, INSTALLATION DRAWINGS AND CHARACTERISTICS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Contractors Guide Central Inverter System Installation

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

Inductive sensor NI10-M18-Y1X-H1141

Charge Regulator SCR 12 Marine

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Mass Charger Alarm Interface GMDSS - Global Maritime Distress & Safety System

Digital input modules

Absolute Rotary Encoder E6CP

How To Power A Schen

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Hand-held thermometer Model CTH7000

Manual. Solar Fountain Mobile Phone Charger

id led 4" square housing FL44

D.C. Motors. Products and specifications subject to change without notice.

+ Incremental interface

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

STRATO LED Drivers 70W, Single output

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Pressure transmitter For general industrial applications Model A-10

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Installation & User Manual Radio Remote rev1.0.3

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Three-phase monitoring relay CM-PFE

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

CompactLogix Power Supplies Specifications

Description. Dimensions. Features. precision works better

Line-Mounted Valves L Series

Power Supplies 3. SDN-P DIN Rail Series

Color Mark Sensor with Red or Green LED E3S-VS

Phone: Fax: Web: info@clrwtr.com

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Analog signal converters CC-E I/I Current / current isolators

Cross-beam scanning system to detect slim objects. 100 mm in

Capacitive Prox E2K-X

Manual. Simrad StructureScan LSS-1 Sonar Module. English

HM-W536 Install Guide

ST Series POWER SUPPLIES USER INSTRUCTIONS

Floodlight Range Installation Guide

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

80 Series - Modular timers 16 A. Features

Air damper actuators

SYSTEM 4C. C R H Electronics Design

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

BB800 Off-Grid Solar System

DCS Input/Output Relay Card Series

Residential Gateway (RG) Battery Backup

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Original instructions Tina 3A/Aps Adaptor unit

Preset Counter signo 721

D. PARAMETER SPECIFICATION Measured Variable: Displacement

Copyrights 2010 Victron Energy B.V. All Rights Reserved

StructureScan HD Module. Installation Guide ENGLISH

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Givare NC-SRS 280 och 880

Tina 2A/B Adaptor unit

Redundancy Module QUINT-DIODE/40

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Instruction Manual Differential Pressure Transmitter

Coils - Connectors. Coils Connectors. Summary. RE / /10 Replaces: RE / Description

Digital Pressure Measuring Instrument MDR480

DS 600. A contact free flux gate based current measurement sensor 600A rms

DC POWER SUPPLY ALIMENTATION C.C.

Adjustment functions for both span and shift have been incorporated

is then retained absolutely without interruption.

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

SYSTEM DESCRIPTION Termination Boards

Voltage Regulator SPAU 341 C. Product Guide

Stroom voor elke toepassing

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

EGSTON Standard E2xFxWx 12W

47000 SERIES - ELECTRONIC TRANSFORMERS

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

MIC-WKT and MIC-WKT-IR

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Toroidal Conductivity Sensor

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Waveguide Access Point WGA631. Product Guide

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Transcription:

APPENDIX / ANHANG / ANNEXE ALPHA ALTERNATOR DIMENSIONS, INSTALLATION DRAWINGS AND CHARACTERISTICS MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com 10000003207/02

CONTENTS: 10000003207/02 1 DIMENSIONS... 3 1.1 Dimensions Alpha alternator model 12/90... 3 1.2 Dimensions Alpha alternator models 12/130, 24/75 and 24/110... 4 1.3 Dimensions Alpha alternator model 24/150... 5 1.4 Dimensions Alpha Pro II regulator... 6 2 INSTALLATION DRAWINGS... 7 2.1 Alpha Alternator model 12/90... 7 2.2 Alpha Alternator models 12/130, 24/75 and 24/110... 8 2.3 Alpha Alternator model 24/150... 9 2.4 Standard Bosch alternator... 10 2.5 Instruction for modification of standard Bosch alternators... 11 2.6 Installation examples for Alpha alternator model 12/90... 12 2.7 Installation examples for Alpha alternator models 12/130, 24/75 and 24/110... 14 3 CHARACTERISTICS... 15 3.1 Charge current versus RPM... 15 4 ORDERING INFORMATION... 16 4.1 Accessoires... 16 4.2 Spare parts... 16 5 EC DECLARATION OF CONFORMITY... 17 2 January 2013 / APPENDIX Alpha alternator - Alpha Pro II regulator / EN

1 DIMENSIONS 1.1 DIMENSIONS ALPHA ALTERNATOR MODEL 12/90 W TERMINAL Figure A-1: dimensions Alpha alternator model 12/90 (enclosure A) EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 3

1.2 DIMENSIONS ALPHA ALTERNATOR MODELS 12/130, 24/75 AND 24/110 PULLEY HUB DETAIL 2.14-2.26 [.084-.089] 4.02-4.06 [.158-.160] 22.24-22.26 [.8755-.8765] 170 [6.7] R=97 [3.8] 12.9 [.508] WIRING DIAGRAM A/C TERMINAL STATOR NEGATIVE OUTPUT 29.2 [1.15] 13.1 [.516] FIELD RECOMMENDED PULLEY HUB LENGTH NOMINAL DIAMETER IS 89 [3.5] 108 [4.25] 250 [9.83] 38.4-39.3 [1.51-1.55] 108 [4.25] 17.0-17.5 [.67-.69] 11.0-11.4 [.43-.45] POSITIVE OUTPUT 29.8-31.2 [1.17-1.23] BLU BLU 36 82.4 [3.25] 14.0-14.4 [.55-.57] 240 [9.45] 100.5-102.7 [3.96-4.05] 33.9 [1.34] POSITIVE OUTPUT M8 THREAD MOUNTING TORQUE 11.3-12.8 Nm [110-110 InLbs] 113 [4.46] 56.6 [2.23] 33 [1.30] NEGATIVE OUTPUT M6 THREAD MOUNTING TORQUE 7.9-9.0 Nm [75-80 InLbs] 5.1 [.20] 15.3-18.3 [.60-.72] 53.3 [2.10] AC TERMINAL FIELD CONNECTOR 20.1 [.79] SLIDABLE BUSHING 12.9 [.508] DIMENSIONS IN MM [INCH] 56.6 [2.23] Figure A-2: dimensions Alpha alternator models 12/130, 24/75, 24/110 and 24/150 (enclosure B) 4 January 2013 / APPENDIX Alpha alternator - Alpha Pro II regulator / EN

1.3 DIMENSIONS ALPHA ALTERNATOR MODEL 24/150 211.8 ±0.5 108 22.68 178.8 ± 0.75 41.2 82.55 Ø 13.0 ± 0.2 R = 15.2 WIRING DIAGRAM STATOR NEGATIVE OUTPUT POSITIVE OUTPUT 123.2 3 x THROUGH HOLE Ø 13.3 5/8-18 UNF-2A THREAD 241 ±0.73 Ø 166.1 Ø 92.0 Ø 89.0 GREEN RED FIELD CONNECTION STATOR TERMINAL 14.2 18.5 ± 0.75 57.3 28.5 17.3 56.5 2.3 83.8 ± 1 166.6 ± 1.2 14.2 33.5 102.6 ± 1 137.7 ± 1.2 4 2.2 Ø 22.25 29.2 PULLEY HUB DETAIL FIELD CONNECTOR 12.7 ± 0.5 20.3 STATOR TERMINAL M5 THREAD MOUNTING TORQUE 2.3-2.8 Nm [20-25 InLbs] 95.8-100.3 ADJUSTMENT FOR MOUNTING BRACKET DIMENSIONS IN MM NEGATIVE OUTPUT M6 THREAD MOUNTING TORQUE 7.9-9.0 Nm [70-80 InLbs] POSITIVE OUTPUT M8 THREAD MOUNTING TORQUE 11.3-12.8 Nm [110-110 InLbs] Figure A-3: dimensions Alpha alternator model 24/150 (enclosure C) EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 5

1.4 DIMENSIONS ALPHA PRO II REGULATOR 95,0 [3.74] 89,8 [3.53] 86,7 [3.41] 109 [4.30] 29,5 [1.16] Figure A-5: dimensions of the Alpha Pro II regulator (all models) 6 January 2013 / APPENDIX Alpha alternator - Alpha Pro II regulator / EN

2 INSTALLATION DRAWINGS 2.1 ALPHA ALTERNATOR MODEL 12/90 ALTERNATOR ALPHA PRO II REGULATOR 8 3 6 W White Yellow Brown Red Blue Black Oil pressure switch 4 1 2 S1 10A 2A 7 5 * + - Temperature sensor Igni on relay BATTERIES * Model Recommended fuse Recommended wire size < 3m 3 5m Figure A-6: Installation drawing Alpha alternator model 12/90 EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 7

2.2 ALPHA ALTERNATOR MODELS 12/130, 24/75 AND 24/110 ALPHA ALTERNATOR ALPHA PRO II REGULATOR 2 8 3 W 6 White Yellow Brown Red Blue Black Oil pressure switch 1 4 5 10A 2A 7 Igni on relay Temperature sensor Figure A-7: Installation drawing Alpha alternator models 12/130, 24/75 and 24/110 8 January 2013 / APPENDIX Alpha alternator - Alpha Pro II regulator / EN

2.3 ALPHA ALTERNATOR MODEL 24/150 ALTERNATOR ALPHA PRO II REGULATOR 3 8 6 6 White Yellow Brown Red Blue Black Oil pressure switch 4 1 10A 2A 5 * 7 Igni on relay Temperature sensor Figure A-8: Installation drawing Alpha alternator model 24/150 EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 9

2.4 STANDARD BOSCH ALTERNATOR ALTERNATOR ALPHA PRO II REGULATOR 8 2 3 6 White Red Blue Black Oil pressure switch Yellow Brown 4 1 10A 5 * 2A 7 Igni on relay Temperature sensor Figure A-9: Installation drawing standard Bosch alternator 10 January 2013 / APPENDIX Alpha alternator - Alpha Pro II regulator / EN

2.5 INSTRUCTION FOR MODIFICATION OF STANDARD BOSCH ALTERNATORS Typical rear view of a Bosch alternator Typische Rückansicht einer Bosch-Lichtmaschine Standaard achteraanzicht van een Bosch dynamo. Vue arrière de l'alternateur Bosch Remove the by-pass on the back side of the brush holder between ground and D Verbinding aan de achterzijde van de borstelhouder tussen massa en D verwijderen By-Pass an der Rückseite des Bürstenhalters zwischen Masse und D entfernen Retirer le conduit à l'arrière du support porte-balais entre la terre et la borne D Warning: Remove connection between D and housing with standard Bosch brushholders. After reinstallation of the brush holder, check with a multimeter if D has no connection between the alternating housing and D Waarschuwing: verbinding tussen D en behuizing bij standaard Bosch-borstelhouders verwijderen. Na herinstallatie van de borstelhouder met een multimeter controleren of D niet in verbinding staat met de behuizing van de dynamo en B.. Warnhinweis: Verbindung zwischen D- und Gehäuse bei Standard-Bosch-Bürstenhaltern entfernen. Nach der erneuten Installation des Bürstenhalters mit einem Universalinstrument messen, ob D keine Verbindung zwischen dem Lichtmaschinengehäuse und B hat. Attention: retirer la connexion entre D et le boîtier à l'aide du porte-balais standard. Vérifier (après avoir réinstallé le support porte-balais) avec un multimètre que D n'a pas de connexion entre le boîtier de l'alternateur et B Figure A-10: standard Bosch alternator (not applicable for Mastervolt alternators) EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 11

2.6 INSTALLATION EXAMPLES FOR ALPHA ALTERNATOR MODEL 12/90 ALPHA PRO II REGULATOR Black Blue Red Yellow Brown White Temp_sense Black Blue Red Brown Figure A-11: This drawing shows the installation of the Alpha alternator 12/90 in combination with a battery isolator to charge two battery banks simultaneously 12 January 2013 / APPENDIX Alpha alternator - Alpha Pro II regulator / EN

ALPHA PRO II REGULATOR YELLOW BRUIN WHITE BLACK BLUE RED ALPHA ALTERNATOR BLUE Figure A-12: Here the installation of the Alpha alternator 12/90 in combination with a Mastervolt DC distribution system is shown. The Mastervolt DC distribution systems are easy-to-install installation kits for central connection of the DC-sources (such as the alternator and the battery charger), the batteries and the DC loads (such as the inverter, the anchor winch or the bowthruster). These DC-distribution systems are standard pre-wired for connection of a battery monitor. See www.mastervolt.com for details. EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 13

2.7 INSTALLATION EXAMPLES FOR ALPHA ALTERNATOR MODELS 12/130, 24/75 AND 24/110 ALPHA PRO II REGULATOR Yellow Brown White BLACK BLUE RED Temp_sense BLUE Figure A-13: This drawing shows the installation of the Alpha alternator models 12/130, 24/75 and 24/110 in combination with a battery isolator to charge two battery banks simultaneously. 14 January 2013 / APPENDIX Alpha alternator - Alpha Pro II regulator / EN

3 CHARACTERISTICS 3.1 CHARGE CURRENT VERSUS RPM 12VDC alternators Amp RPM 24VDC alternators Amp RPM Output power is measured in combination with Alpha Pro II regulator at nominal voltage (25 C) Figure A-15: Characteristics for Mastervolt alternators: charge current versus RPM EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 15

4 ORDERING INFORMATION 4.1 ACCESSOIRES Part number Description 83007021 Battery isolator BI 702 for two battery banks. For alternators up to 70 Amps, 83007030 Battery isolator BI 703 for three battery banks. For alternators up to 70 Amps, 83012021 Battery isolator BI 1202 for two battery banks. For alternators up to 120 Amps, 83012031 Battery isolator BI 1203 for three battery banks. For alternators up to 120 Amps, 83116025 Battery Mate 1602-IG, low voltage drop battery isolator for two battery banks. For alternators up to 160 Amps 83116035 Battery Mate 1603-IG, low voltage drop battery isolator for three battery banks. For alternators up to 160 Amps 6384010000 Industrial DC fuse 100A DIN 00 6384012500 Industrial DC fuse 125A DIN 00 6384016000 Industrial DC fuse 160A DIN 00 6384510000 Industrial DC fuse 100A DIN 1 6384512500 Industrial DC fuse 125A DIN 1 6384516000 Industrial DC fuse 160A DIN 1 6384520000 Industrial DC fuse 200A DIN 1 6381001000 Fuse base DIN 0 (max. 160A) 6381002000 Fuse base DIN 1 (max. 250A) Mastervolt can offer a wide range of products for your electrical installation, including battery chargers, AGM- and Gel batteries, DC-switches, battery monitoring panels and DC distribution kits See our website www.mastervolt.com for an extensive overview of all our products 4.2 SPARE PARTS These parts are for after-sales applications only: Part number Description 45512000 Alpha Pro II regulator for alternators models 12/90 and 12/130, 24/75, 24/110, 24/150, Bosch 12V and 24V alternators 41500500 Battery temperature sensor 48400110 Brush holder for alternator models 12/90 12/130, 24/75 and 24/110 48400150 Brush holder for alternator model 24/150 48400010 Pulley for two belts, for alternators model 12/90 48400020 Pulley for two belts, for alternators models 12/130, 24/75and 24/110 16 January 2013 / APPENDIX Alpha alternator - Alpha Pro II regulator / EN

5 EC DECLARATION OF CONFORMITY We, Manufacturer Mastervolt Address Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Declare under our sole responsibility that Product : Alpha Pro II Is in conformity with the provisions of the following EC directives: 2006/95/EC (Safety directive); the following harmonized standards have been applied: EN 60950-1:2001+ A11:2004 (LVD) 2004/108/EC (EMC directive); the following harmonized standards have been applied: EN 61000-6-3: 2007 Emission standard for residential, commercial and light-industrial environments EN 61000-6-2: 2005 Immunity for industrial environments EN 61000-4-2 Electrostatic discharge immunity test EN 61000-4-4 Electrical fast transient/ burst immunity test 2011/65/EU (RoHs Directive) Amsterdam, 18/12/2012 Mastervolt international B.V. Daan Hobbelen, Product development manager Marine & Mobile EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 17

EN / APPENDIX Alpha alternator - Alpha Pro II regulator / January 2013 19

Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel : + 31-20-3422100 Fax : + 31-20-6971006 Email : info@mastervolt.com www.mastervolt.com