Challenging Skew: Higgins Road Steel I-Girder Bridge over I-90 OTEC 2015 - October 27, 2015 Session 26



Similar documents
Overhang Bracket Loading. Deck Issues: Design Perspective

APPENDIX H DESIGN CRITERIA FOR NCHRP PROJECT NEW BRIDGE DESIGNS

Engineering for Stability in Bridge Construction: A New Manual and Training Course by FHWA/NHI

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

Quality and the Bridge Engineer

Safe & Sound Bridge Terminology

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

IH-635 MANAGED LANES PROJECT, SEG. 3.2

US 51 Ohio River Bridge Engineering and Environmental Study

Index Series Prestressed Florida-I Beams (Rev. 07/12)

FEBRUARY 2014 LRFD BRIDGE DESIGN 4-1

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Steel joists and joist girders are

REPAIR AND RETROFIT OF BRIDGES DAMAGED BY THE 2010 CHILE MAULE EARTHQUAKE

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

Introduction to LRFD, Loads and Loads Distribution

Long-term serviceability of the structure Minimal maintenance requirements Economical construction Improved aesthetics and safety considerations

ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE ABSTRACT

Reinforced Concrete Slab Design Using the Empirical Method

METHOD OF STATEMENT FOR STATIC LOADING TEST

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

AASHTOWare Bridge Design and Rating Training. STL8 Single Span Steel 3D Example (BrDR 6.6)

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Rehabilitation of the Red Bank Road Bridge over Hoover Reservoir. Presented By: Doug Stachler, P.E.

BRIDGE RESTORATION AND LANDSLIDE CORRECTION USING STRUCTURAL PIER AND GRADE BEAM

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Outline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.

Handling, Erection and Bracing of Wood Trusses

Pro-Lift Steel Pile Foundation Repair

Joist. Reinforcement. Draft 12/7/02

Residential Deck Safety, Construction, and Repair

Optimum proportions for the design of suspension bridge

High Strain Dynamic Load Testing of Drilled Shafts

Structural Performance of Highway Bridges under Given Foundation Settlements

3.1 Historical Considerations

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

NUMERICAL ANALYSIS OF A HORIZONTALLY CURVED BRIDGE MODEL

Quality Control and Quality Assurance Guide

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

CONSTRUCTION OF THE HOOVER DAM BYPASS BRIDGE Updated 29 May 2009

Informational Workshop Public Meeting Kanawha Falls Bridge Project

Analysis of the Response Under Live Loads of Two New Cable Stayed Bridges Built in Mexico

Forensic engineering of a bored pile wall

Step 11 Static Load Testing

Page & Turnbull imagining change in historic environments through design, research, and technology

Detailing of Reinforcment in Concrete Structures

Canadian Standards Association

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

INSTALLATION. General. Important Note. Design. Transport

Investigation of the November 2, 2013 collapse of concrete beams at Fort Lauderdale-Hollywood Airport runway project

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

TECHNICAL USER MANUAL for STANDARD HALF THROUGH UNDERBRIDGES Z TYPE

Virginia Approach Spans

Code of Standard Practice for Timber Frame Structures

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Table of Contents. July

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

1,045 m length of the Deh Cho Bridge

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

Truss. are both simple and A Matsuo Example continuous trusses. The

Value Engineering vs. Alternate Designs in Bridge Bidding

U.S. Department of Labor Occupational Safety and Health Administration Directorate of Construction. April 2015

PART 1 GENERAL 1.1 SECTION INCLUDES

REPAIR AND STRENGTHENING OF HISTORICAL CONCRETE BRIDGE OVER VENTA RIVER IN LATVIA

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

Analysis of the Interstate 10 Twin Bridge s Collapse During Hurricane Katrina

POST AND FRAME STRUCTURES (Pole Barns)

INTRODUCTION TO BEAMS

Chapter 7 Substructure Design General Substructure Considerations Foundation Design Process

This manual was produced using ComponentOne Doc-To-Help.

STEEL TABLE OF CONTENTS CHAPTER 11

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

Session 5D: Benefits of Live Load Testing and Finite Element Modeling in Rating Bridges

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

Preliminary steel concrete composite bridge design charts for Eurocodes

STRUCTURAL FORENSIC INVESTIGATION REPORT

Technical Analysis and High-End Structural Design

Prestressed Concrete I-Beam and TxGirder Haunch Design Guide

Numerical Analysis of the Moving Formwork Bracket Stress during Construction of a Curved Continuous Box Girder Bridge with Variable Width

Designed and Engineered to Perform

LOAD TESTING OF SOME NEW BRIDGES IN LATVIA

Evaluation of Appropriate Maintenance, Repair and Rehabilitation Methods for Iowa Bridges

SECTION 7 Engineered Buildings Field Investigation

REHABILITATION PACKAGE 1-a

DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT

LOAD TESTING FOR BRIDGE RATING: DEAN S MILL OVER HANNACROIS CREEK

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

The Design and Construction of the Chitose Bridge

~iffiui ~ Bridge Condition Survey. Inspection Date: 21 May 2003 District: San Angelo County: Tom Green Highway:

Steel Bridge Design Handbook

The Collapse of Building 7 by Arthur Scheuerman December 8, 06

New approaches in Eurocode 3 efficient global structural design

ARCH 331 Structural Glossary S2014abn. Structural Glossary

Transcription:

2014 HDR Architecture, 2014 2014 HDR, HDR, Inc., all all rights reserved.

Challenging Skew: Higgins Road Steel I-Girder Bridge over I-90 OTEC 2015 - October 27, 2015 Session 26 Brandon Chavel, PhD, P.E., Lance Peterman, P.E., S.E. 2014 HDR, all rights reserved.

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Detailing and Fit o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Project Location Hoffman Estates, IL 30 miles NW of Chicago Twin bridges span over I-90 I-90 reconstructed and widened Heavily traveled corridor o (118,000 vehicles per day) I-90

Project Overview Existing Bridges I957 I978 -WB 5 simple spans: 471 ft total length -WB 60 deep plate girders -WB fracture critical substructure -WB no skew counterfort wall abut -EB 3 continuous spans: 503 ft total length -EB 81 deep plate girders -EB skewed counterfort wall abut

Project Overview New Bridges Two 280 ft continuous spans: 560 ft total length 49-3 wide deck to carry three lanes 70º skew all supports Six plate girder cross section Webs are 9-6 deep X-type intermediate cross frames Full depth diaphragm along skew at abutments Full depth diaphragm normal to girders at pier 8 deck

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Behavior of Skewed Structures Girder differential deflection causes cross-section lateral deflections and twist Non skewed diaphragms o Diaphragm Loads o Flange Lateral Bending

Behavior of Skewed Structures Transverse load paths through cross frames Nuisance Stiffness Effects Lateral reactions develop at the bearings

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Framing Plan Opposite direction of rotation between span 1 and 2 G1 G6 G1 G6 SPAN 1 LOOKING TOWARDS ABUT 2 SPAN 2 LOOKING TOWARDS ABUT 2

Framing Plan Selectively remove cross frames near the pier o Nuisance stiffness, reduce transverse load paths Use full depth diaphragms at interior pier location o Attract load at two distinct locations Use staggered cross frame pattern at skewed ends o Eliminate the transverse load paths

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

3D Finite Element Analysis Properly model girder torsional stiffness and warping stiffness Can account for load shifting between girders Explicitly model all cross frame members and full-depth diaphragms Live load influence surface analysis 2D grid analysis inaccurate results: o Cross frame forces o Girder displacements o Ref: NCHRP Report 725

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Steel Details Full-depth end diaphragm (length ~ 23.5 ft) o Too long for a K-type cross frame Auxiliary stiffeners (back-up stiffeners)

End Diaphragm Full depth diaphragm connected to bent stiffener plate Bolted jacking stiffener installed after end diaphragm due to conflict Bolted Jacking Stiffener

Full Depth Diaphragm at Pier Detail to avoid interference with fixed bearing at skewed pier

Lateral Bracing Prevent stability problems during construction o Increases global buckling strength of the initial twin girder systems during steel erection Prevent excessive deflections due to wind loading during construction before deck is placed Placed at the top flange level near neutral axis to limit participation in resisting live load Bolted directly to flange Not full-length Span 5

Fit Condition Severe skew leads to: o Out of plumb webs after dead load is applied o Excessive bearing rotation o Try to control this rotation via detailing AASHTO Article 6.7.2 o Fit condition to be specified in the contract documents Span 5

Fit Condition NSBA publication: Skewed and Curved Steel I-Girder Fit Describes fit and customary practices, 3 choices: o No load fit (NLF) o Steel dead load fit (SDLF) o Total dead load fit (TDLF) Provides recommendations o Straight square bridges: Any o Straight skewed bridges: SDLF or TDLF o Curved bridges (up to ~ 250 span): SDLF, then NLF Span 5

Detailing and Fit For SDLF and TDLF the crossframes are forced into place and the girders are twisted out of plumb during the erection Steel Dead Load Fit (SDLF) chosen o Disc bearing accommodates rotations Concrete dead load Live load o Erection simpler & faster than TDLF o Limited construction windows Span 5

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Bearing Design Fixed Bearing Guided Expansion Bearing Non Guided Expansion Bearing

Fixed Bearing Design Large horizontal reactions from skew Horizontal reactions increase with distance from centerline of bridge

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Deck Placement Analysis Girder camber is dependent on the sequence of the deck placement Differences in deflection o Single monolithic deck pour deck placement sequence Verify deck stresses resulting from pour sequence will not result in cracking

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Conceptual Erection Sequence

Conceptual Erection Sequence Analysis Use LARSA 3D FEM to check: o Temporary Support Structure Placement maintain three I-90 lanes in each direction o Hold Crane Placement o Girder Stresses, Deflections, Reactions (no uplift) Potential issues: o Reduced Girder buckling capacity o Loading is less than in the final condition, but the girder capacity is also less

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Pier Design 130 long Severe skew and fixed bearing condition led to high lateral forces in opposite directions Segmented pier: o Better accommodate internal thermal force demands o Reduce torsion in pier cap Circular columns directly under girders to effectively carry vertical reaction

Pier Cap

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Shop Fit-Up

Abutments Stub abutments on battered piles behind soldier pile wall Soldier pile wall to limit span lengths o 600 foot long soldier pile walls parallel to I-90 o Minimized structure excavation in tight space Avoid conflicts with existing piles

Pier Cap Detailing Bar Terminator Anchorage Reinforcement

Steel Erection

Deck Placement Issue: o Difference between paver maximum skew and bridge skew o Steel framing potential twist in an unintended manner Solution: o Place concrete along bridge skew ahead of paver skew and use retarder to delay set

Deck Placement Deck overhang brackets for 9-6 deep plate girder

Swivel Type Modular Expansion Joint Multi-directional movement capability Detail girders and end diaphragms to accommodate joint Special closure pour at joints o To minimize movement due to dead load effects (racking) o To reduce shrinkage effects Span 5

Presentation Outline Project Overview Design o Behavior of Skewed Structures o Framing Plan o 3D Finite Element Analysis o Steel Details and Fit Condition o Bearing Design o Deck Placement Analysis o Conceptual Erection Sequence o Pier Design Construction Summary

Summary Consider 3D FE analysis for severely skewed supports Recognize alternative load paths at severely skewed supports Be cognizant of high lateral forces at fixed bearings of a skewed support Specify fit condition for the girders and cross frames Provide feasible erection scheme for complex projects Place deck concrete along skew

Acknowledgments Client: Illinois Tollway General Contractor: Dunnet Bay Construction Steel Fabricator: Industrial Steel Construction Steel Erector: Danny s Construction

QUESTIONS