Comparison of NEMA and IEC schematic diagrams



Similar documents
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Electrical Symbols and Line Diagrams

EET272 Worksheet Week 8

Low Voltage Fuses For Motor Protection

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Industrial Automation Commonly-Used Terms

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Programming A PLC. Standard Instructions

ETZGAR CONVEYOR COMPANY Controls Section v12.05

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Building an Auto-Start Rotary Three Phase Converter. by: Matt Isserstedt

TERMINAL MARKINGS AND INTERNAL WIRING DIAGRAMS SINGLE PHASE AND POLYPHASE MOTORS MEETING NEMA STANDARDS

Sentron Series Circuit Breakers

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

Catalog January. Heavy industrial power applications Motor contactors and starters

Bolted contact switches. Pringle switches

AC motor control circuits

SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Reverse-feed applications for circuit breakers

E-Series protective relay family

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

SECTION VARIABLE FREQUENCY DRIVES

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

Fundamentals of Power

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

NATIONAL CERTIFICATE (VOCATIONAL)

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Eaton s E-Series protective relay family

Rotary Phase Converters

Circuit Breakers. Next Generation of Protection Capabilities

SURGE PROTECTIVE DEVICES

How To Test A Power Switch On A Power Supply

Cable/Conduit Conversion

How To Protect A Motor From Overcurrent

How To Understand The Electrical Power Supply Of A Power Supply System

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Reversing starter circuit for single phase induction motors Updated 1 st September 2008

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

101 BASICS SERIES LEARNING MODULE 19: STARTERS AND CONTACTORS. Cutler-Hammer

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Reducing sizes of control power transformers and power supplies with Eaton s XT IEC motor control

3PH2 or 3PHE 3 Phase Control Board

Creating Relay Logic Diagrams

Name: Air Conditioning, Heating and Refrigeration ( )

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

Contactor and Starter Ratings

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

MOTOR PROTECTION AGAINST SINGLE-PHASING

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Motor Protection Voltage Unbalance and Single-Phasing

EDS / EFS Series Control Stations

Speed Control Relays SX2

Installation Manual Version 7.3 IMPORTANT:

EET272 Worksheet Week 9

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

All about Motors. Page. Motor protection 8-3. Notes on engineering Circuit documents Power supply Control circuit supply 8-24

AutoCAD Electrical Symbol Libraries

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

ESP PANELS TM & SYSTEM COMPONENTS. Instruction and connection manual

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Test Code: 8094 / Version 1

Motor Circuit Protection Tables

Unit 33 Three-Phase Motors

Magnetic Starter - 30A, 120/240V Coils

Occupational Profile: Electrical & Electronics Engineering Technician

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

First Year (Electrical & Electronics Engineering)

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

PowerFlex 700 and 700H Packaged Drives. Technical Data

How To Choose A Transformer

OPITO APPROVED STANDARD

Short Circuit Current Calculations

Schematic Model Family Electrical P C 01

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Applications. Remote Display Mounting Kits

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Fusible Disconnect Switch

Contactors Low Voltage

Engineering innovation

Energy in Electrical Systems. Overview

What is a multimeter?

UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL

stard network diagram symbols

CHECK LIST OF SITE INSPECTION ON LV ELECTRICAL INSTALLATION (Basic Information to be filled by Consultant)

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Transcription:

Cross-Reference MZ081001EN Comparison of NEMA and IEC schematic diagrams General With the increasing emphasis on globalization, many industries are now looking to all parts of the world to produce, market, and sell their products. Electrical manufacturers are no exception. Since the electrical standards adopted by various nations may vary, the markings and symbols used to describe electrical control products vary as well. Whether it is a complex control system on a machine tool or a simple across-the-line motor starter, the need to recognize and understand these symbols becomes more important. It is possible that products from all parts of the world are being used in any one facility. The purpose of this document is to provide a simple cross reference of common schematic/wiring diagram symbols used throughout various parts of the world. The following tables describe the device and show the symbol by area of usage.

Cross-Reference MZ081001EN Comparison of NEMA and Capacitor Circuit breaker Magnetic only Thermal-magnetic Coil Basic contacts Normally closed Normally open Time delay contacts Normally closed, time closed Normally closed, time open Normally open, time closed Normally open, time open Disconnect switch Non-fused Fused Fuse 2

Comparison of NEMA and Cross-Reference MZ081001EN Earth (ground) Induction motor Single-phase Three-phase Indicating lights Standard Push-to-test Insert color code inside symbol Insert color code next to symbol Meters Insert color code inside symbol Overload relays Thermal element Insert function code inside symbol Insert function code next to symbol Magnetic element Pushbuttons Illuminated Momentary (N.C.) Momentary (N.O.) Mushroom head (N.C.) Mushroom head (N.O.) Resistor 3

Cross-Reference MZ081001EN Comparison of NEMA and Switches Float (N.C.) Float (N.O.) Flow (N.C.) Flow (N.O.) Foot (N.C.) Foot (N.O.) Limit (N.C.) Limit (N.O.) Selector switch Two-position Three-position 4

Comparison of NEMA and Cross-Reference MZ081001EN Switches Pressure (N.C.) Pressure (N.O.) Temperature (N.C.) Temperature (N.O.) Transformer Current Voltage 5

Cross-Reference MZ081001EN Comparison of NEMA and Common Schematic Diagrams: Across the Line Non-Reversing Starters with Start Stop Pushbuttons Power circuit Control circuit Common Schematic Diagrams: Across the Line Non-Reversing Starters with Hand Off Auto Selector Switch Power circuit starter Control circuit starter 6

Comparison of NEMA and Cross-Reference MZ081001EN Common Schematic Diagrams: Across the Line Reversing Starters with Forward Reverse Stop Pushbuttons Power circuit reversing starter Control circuit reversing starter Common Schematic Diagrams: Combination Starter with Fused Disconnect Switch and Start Stop Pushbuttons Power circuit 7

Cross-Reference MZ081001EN Comparison of NEMA and Common Schematic Diagrams: Combination Starter with Fused Disconnect Switch and Start Stop Pushbuttons Control circuit Common Schematic Diagrams: Manual Starter Power circuit Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2013 Eaton All Rights Reserved Printed in USA Publication No. MZ081001EN / Z14526 November 2013 Eaton is a registered trademark. All other trademarks are property of their respective owners.