Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current 4 A current 3 A limited Class 2 per UL 1310 and NEC article 725 (selectable) current 3 A limited Class 2 per UL 1310 and NEC article 725 (selectable) Dual output IP 20 current 4/4 A (switchable) Combination output IP 20 1 x DC 24 V / 1 x DC 30 V current 5/4 A (switchable) 1 x DC 24 V / 1 x DC 30 V current 7 A Rated input voltage AC 120/130 V with integrated earth-fault detection current 2.4 A 1 unit Unit 3RX9 307-0AA00 1 3RX9 307-1AA00 1 4FD5 183-0AB40-1A 1 4FD5 183-0AB30-1A 1 3RX9 305-1AA00 1 3RX9 306-1AA00 1 6EP1 354-1AL01 1 1 6EP1 354-1AL01 16/126 Discount Code: AS-Interface
current 2.4 A current 4 A current 3.3 A 3RX9 307-0AA0 3RX9 307-1AA0 4FD5 213-0AA10-1A Rated input voltage in V AC 115/230 (selectable) AC 115/230 AC 230/400 (repositionable) Input Single-phase AC Single-phase AC Single- and two-phase AC Range selection by changeover switch by plug 1 Voltage range in V AC 195... 253 / 102... 132 AC 197... 430 Overvoltage strength EN 61 000-4-1 Mains buffering in ms at I e Rated > 20 > 20 at 230 V; > 60 at 400 V Mains frequency rated value I range in Hz 50/60/47... 63 Built-in input fuse in A T 2 T 5 (not accessible) T 3 (not accessible) Recommended m.c.b (IEC 898) from 16 characteristic C in mains supply circuit Rated voltage U a Rated in V DC 30 Total tolerance in V DC 29.5... 31.6 (0... 10 khz, AS-i+/AS-i-) (10... 500 khz, AS-i+/AS-i-) Rated current value I a Rated in A 2.4 (power boost: 2.8) 4 (power boost: 4.5) DC 3.3 (power boost: DC 4) Efficiency at U a Rated, I a Rated in % approx. 85 Power loss at U a Rated, I a Rated in W approx. 10 approx. 18 approx. 15 Overvoltage protection of outputs no Current limitation in A > 2.8 > 4.5 > 5 Primary/secondary isolation SELV to EN 60 950 SELV to EN 60 950 SELV to EN 60 950 (in preparation) class (EN 60 950/IEC 950) I Protection IP 20 Approvals CE, UL, ship building CE, UL, CSA (in preparation) CE, UL (in preparation) Emitted interference EN 50 081-1 Ambient temperature range in C 25... +55 45... +55 Transport and storage temperature range in C 25... +60 45... +80 Humidity class max. 80% rel. humidity Input connection Cage Clamp connection (0.8... 2.5 mm 2 ) connection AS-Interface + Cage Clamp connection (0.8... 2.5 mm 2 ) connection AS-Interface - Cage Clamp connection (0.8... 2.5 mm 2 ) connection shield S Cage Clamp connection (0.8... 2.5 mm 2 ) connection Ground Cage Clamp terminals (0.8... 2.5 mm 2 ) Dimensions (W x H x D) in mm 46 110 136 75 135 107 75 135 103 Weight in kg approx. 0.8 1 1.15 Mounting Snap-on mounting onto standard rail DIN EN 50 022-35 x 7.5 mm Mounting onto standard mounting rail 16/127
Dual output IP 20 2 DC 30 V Combination output IP 20 1 DC 24 V / 1 DC 30 V 3RX9 305-1AA00 current in A 4/4 5/4 Input voltage in V Input Range selection AC 115/230 (selectable) Single-phase AC by changeover switch Input voltage range in V AC 195... 253 / 102... 132 Overvoltage strength EN 61 000-4-1 Mains buffering in ms at I e Rated > 20 Mains frequency rated value I range in Hz 50/60/47... 63 Built-in input fuse in A T 5 (not accessible) 3RX9 306-1AA00 Rated voltage U a Rated in V 2 x DC 30 DC 30/DC 24 Total tolerance DC 29.5... 31.6 DC 29.5... 31.6/DC 24 ± 2 % (0... 10 khz, AS-Interface+/AS-Interface-) (10... 500 khz, AS-Interface+/AS-Interface-) Rated current value I a Rated in A 2x4 4/5 Efficiency at U a Rated, I a Rated in % approx. 85 Power loss at U a Rated, I a Rated in W approx. 36 Overvoltage protection of outputs no Current limitation in A > 4 (power boost 4.5) > 4/> 5 (power boost 4.5 / 5.5) Primary/secondary isolation SELV to EN 60 950 SELV to EN 60 950 (in preparation) class (EN 60 950/IEC 950) 1 Protection IP 20 Approvals CE, UL, CSA CE, UL, CSA (in preparation) Emitted interference EN 50 081-1 Ambient temperature range in C 45... +55 Transport and storage temperature range in C 45... +60 Humidity class max. 80% rel. humidity Input connection Cage Clamp connection (0.8... 2.5 mm 2 ) connection AS-Interface + Cage Clamp connection (0.8... 2.5 mm 2 ) connection AS-Interface - Cage Clamp connection (0.8... 2.5 mm 2 ) connection shield S Cage Clamp connection (0.8... 2.5 mm 2 ) Dimensions (W x H x D) in mm 150 x 135 x 107 Weight in kg approx. 2 Mounting Snap-on mounting onto standard rail DIN EN 50 022-35 x 7.5 mm 16/128
with integrated earth-fault detection 6EP1 354-1A01 current in A 7 2.4 Rated input voltage in V AC 120... 230 AC 115/230 Input Range selection by variable range input by changeover switch Voltage range in V AC 93... 264 / DC 110... 350 AC 195... 253 / 102... 132 Overvoltage strength VDE 0160 Limiting curve W2 EN 61 000-4-1 Mains buffering in ms at I e Rated < 20 at 93/187 V > 20 Mains frequency rated value I range in Hz 0/50/60/47... 63 Built-in input fuse in A T 6.3 (not accessible) T 2 Recommended circuit-breakers (IEC 898) in A 16 with Characteristic C or 8 with Characteristic B Rated voltage U a Rated in V DC 30 Total tolerance DC 29.5... 31.6 (0... 10 khz, AS-Interface+/AS-Interface-) (10... 500 khz, AS-Interface+/AS-Interface-) Rated current value I a Rated in A 7 2.4 (power boost: 2.8) Efficiency at U a Rated, I a Rated in % > 85 Power loss at U a Rated, I a Rated in W < 37 10 Overvoltage protection of outputs no Current limitation in A from approx. 7.4 > 2.8 Stabilized current characteristic approx. 7.4 A Primary/secondary isolation SELV to EN 60 950 class (EN 60 950/IEC 950) Class I to IEC 536 1 Protection IP 20 to EN 60 529 IP 20 Approvals CE, UL/cUL CE, UL, CSA (in preparation) Emitted interference EN 50 081-1, EN 55 022 Cl. B EN 50 081-1 Ambient temperature range in C 0... +55 25... +55 Transport and storage temperature range in C 25... +85 25... +60 Humidity class F to DIN 40 040 max. 80% rel. humidity Input connection 1 terminal each for 0.5... 2.5 mm 2 Cage Clamp connection (0.5... 2.5 mm 2 ) connection AS-Interface + 3 terminals for 0.5... 2.5 mm 2 Cage Clamp connection (0.5... 2.5 mm 2 ) connection AS-Interface - 3 terminals for 0.5... 2.5 mm 2 Cage Clamp connection (0.5... 2.5 mm 2 ) connection shield S 2 terminals for 0.5... 2.5 mm 2 Cage Clamp connection (0.5... 2.5 mm 2 ) Dimensions (W x H x D) in mm 200 125 135 92 110 136 Weight in kg 1.8 1.1 Mounting for snap-on mounting onto standard rail Snap-on mounting onto standard rail DIN EN 50 022-35 15 mm and S7 rail DIN EN 50 022-35 x 7.5 mm Additional function Integrated 3RK1 408-8KE00-0AA2 earth fault detection module and isolation of the AS-Interface voltage with corresponding circuit 16/129
135 135 Actuator-Sensor-Interface Dimension drawings 3RX9 307-0AA00 3RX9 307-1AA00 107 75 g_nsa_xx_00121b 3RX9 305-1AA00, 3RX9 306-1AA00 107 150 g_nsa_xx_00122b g_nsa_de_00123b 6EP1 354-1AL01 g_nsa_de_00124b 16/130