LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly
|
|
|
- Lucas Lynch
- 10 years ago
- Views:
Transcription
1 Overview Safety instructions 1 Power supply Operating Instructions Description, device design, dimension drawing 2 Mounting/disassembly 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals, EMC 7 Ambient conditions 8 Applications 9 5 V / 3 A 6EP1311-1SH03 5 V / 6.3 A 6EP1311-1SH13 12 V / 1.9 A 6EP1321-1SH03 12 V / 4.5 A 6EP1322-1SH03 15 V / 1.9 A 6EP1351-1SH03 15 V / 4 A 6EP1352-1SH03 24 V / 1.3 A 6EP1331-1SH03 24 V / 2.5 A 6EP1332-1SH43 24 V / 4 A 6EP1332-1SH52 Environment 10 Service and support C98130-A7560-A
2 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach NÜRNBERG GERMANY C98130-A7560-A P 05/2013 Technical data subject to change Copyright Siemens AG All rights reserved
3 Overview are powerful power supplies which - thanks to their flat stepped profile - are extremely flexible for use in a host of applications (for example, in installation distribution boards). The 12 V and 24 V versions are ideal as power supplies for the LOGO! logic modules. The key benefits of the product include: Flat LOGO! mechanical design Wide-range input for voltages from 85 to 264 VAC and operation with DC voltage Adjustable output voltage Green LED for "Output voltage OK" Ambient temperature -20 C C (derating from +55 C) Constant current under overload conditions for reliable connection of difficult loads When you turn on the power supply, a power reserve of 1.5 times rated current is available for typ. 200 ms Export benefits thanks to global certifications Operating Instructions, , C98130-A7560-A
4 Overview Ordering data The following device options are available: stabilized power supply Type Input 85 to 264 VAC 110 to 300 VDC Output 5 VDC / 3 A Input 85 to 264 VAC 110 to 300 VDC Output 5 VDC / 6.3 A Input 85 to 264 VAC 110 to 300 VDC Output 12 VDC / 1.9 A Input 85 to 264 VAC 110 to 300 VDC Output 12 VDC / 4.5 A Input 85 to 264 VAC 110 to 300 VDC Output 15 VDC / 1.9 A Input 85 to 264 VAC 110 to 300 VDC Output 15 VDC / 4 A Input 85 to 264 VAC 110 to 300 VDC Output 24 VDC / 1.3 A Input 85 to 264 VAC 110 to 300 VDC Output 24 VDC / 2.5 A Input 85 to 264 VAC 110 to 300 VDC Output 24 VDC / 4 A Order number 6EP1311-1SH03 6EP1311-1SH13 6EP1321-1SH03 6EP1322-1SH03 6EP1351-1SH03 6EP1352-1SH03 6EP1331-1SH03 6EP1332-1SH43 6EP1332-1SH52 4 Operating Instructions, , C98130-A7560-A
5 Table of contents Overview Safety instructions Description, device design, dimension drawing Device description Connections and terminal designation Potentiometer Status displays and signaling Block diagram Dimensions and weight Mounting/disassembly Mounting position, mounting clearances Standard mounting position Other mounting positions Installation Line-side connection Output-side connection Technical data Input Output Efficiency and power loss Closed-loop control Protection and monitoring MTBF Mechanical system Accessories Dimension drawing Safety, approvals, EMC Safety Test voltage Certifications EMC...44 Operating Instructions, , C98130-A7560-A
6 Table of contents 8 Ambient conditions Applications Parallel connection to increase power rating Parallel connection for redundancy Series connection for increased voltage Protection against short-time voltage dips Environment Service and support Operating Instructions, , C98130-A7560-A
7 Safety instructions 1 WARNING Correct handling of the devices When operating electrical devices, it is inevitable that certain components will carry dangerous voltages. Therefore, failure to handle the units properly can result in death or serious physical injury as well as extensive property damage. Only appropriately qualified personnel may work on or in the vicinity of this equipment. Perfect, safe, and reliable operation of this equipment is dependent on proper transportation, storage, installation and mounting. Before installation or maintenance work can begin, the system's main switch must be switched off and measures taken to prevent it being switched on again. If this instruction is not observed, touching live parts can result in death or serious injury. Operating Instructions, , C98130-A7560-A
8 Safety instructions 8 Operating Instructions, , C98130-A7560-A
9 Description, device design, dimension drawing Device description are primary switched-mode power supplies for connection to a 1-phase AC system or to DC systems. An electronically regulated DC voltage that can be set via a potentiometer is available at the output of the device. The output of the device is isolated, no-load proof and short-circuit proof. The LED display indicates the operating status Line input DC output Potentiometer Indicator light (output voltage OK) Lug for unlocking with a screwdriver Natural convection Clearance above/below Figure 2-1 Design (example of 6EP1311-1SH13) Operating Instructions, , C98130-A7560-A
10 Description, device design, dimension drawing 2.2 Connections and terminal designation 2.2 Connections and terminal designation The line input terminals 1 can be used to establish the connection to supply voltage. The output terminals 2 are used to connect to the loads to be supplied (see also Section Installation (Page 23)). Connections and terminal designations 1 line input L1, N 2 Output + 2 Output One screw terminal each Two screw terminals Two screw terminals Figure 2-2 Terminal data 10 Operating Instructions, , C98130-A7560-A
11 Description, device design, dimension drawing 2.3 Potentiometer 2.3 Potentiometer The potentiometer 3 on the front of the device is used to set the output voltage. The output voltage is set to the rated value at the factory and can be set within certain limits; for example, to compensate voltage drops across long supply lines to the connected load. Figure 2-3 Potentiometer (example of 6EP1311-1SH13) Type Factory setting Setting range 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) 5 V V 12 V V 15 V V 24 V V NOTICE Thermal overload possible When adjusting the output voltage to > 24 V / > 15 V / > 12 V or > 5 V, the output current must be derated by 4%/V. Note Actuation of the potentiometer is allowed only by means of an insulated screwdriver. For notes on actuating the potentiometer (screwdriver, torque), see Figure 2-2 Terminal data (Page 10). Operating Instructions, , C98130-A7560-A
12 Description, device design, dimension drawing 2.4 Status displays and signaling 2.4 Status displays and signaling 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Status display Green LED for output voltage OK Figure 2-4 Operational displays and signals (example of 6EP1311-1SH13) Signaling 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) LED 4 lights up green LED 4 off Normal operation, output voltage present Output voltage not present 12 Operating Instructions, , C98130-A7560-A
13 Description, device design, dimension drawing 2.5 Block diagram 2.5 Block diagram Figure 2-5 Block diagram Operating Instructions, , C98130-A7560-A
14 Description, device design, dimension drawing 2.6 Dimensions and weight 2.6 Dimensions and weight 54 57,5 52,6 27,5 90 Figure 2-6 Dimension drawing 6EP1311-1SH03, 6EP1321-1SH03, 6EP1351-1SH03, 6EP1331-1SH03 57, ,6 27,4 90 Figure 2-7 Dimension drawing 6EP1311-1SH13, 6EP1322-1SH03, 6EP1352-1SH03, 6EP1332-1SH43 14 Operating Instructions, , C98130-A7560-A
15 Description, device design, dimension drawing 2.6 Dimensions and weight 57, ,6 27,5 90 Figure 2-8 Dimension drawing 6EP1332-1SH52 Dimensions (W H D) in mm 6EP1311-1SH03 (5 V / 3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Weight Approx kg Approx kg Approx kg Operating Instructions, , C98130-A7560-A
16 Description, device design, dimension drawing 2.6 Dimensions and weight 16 Operating Instructions, , C98130-A7560-A
17 Mounting/disassembly 3 WARNING Installing the device in a housing or a control cabinet The power supplies are built-in units. They must be installed in a casing or control cabinet to which only qualified personnel have access. The devices can be mounted in a control cabinet on standard mounting rails according to EN x7,5/15. Mounting To mount the device, position it with the mounting rail guideway at the upper edge of the DIN rail and press down to lock it into place. If this is too difficult, press slider 1 at the same time, as described for "Disassembly". Disassembly To remove, pull up the slider 1 using a screwdriver 2 and disengage the device at the bottom edge of the DIN rail. Then you can remove the device from the upper edge of the DIN rail. Figure 3-1 Disassembly (example of 6EP1311-1SH13) Operating Instructions, , C98130-A7560-A
18 Mounting/disassembly WARNING Use in hazardous zones If the device is to be used in a hazardous zone (Ex II 3G Ex na IIC T3) it must be installed in a distributor box with degree of protection IP54 or higher. 18 Operating Instructions, , C98130-A7560-A
19 Mounting position, mounting clearances Standard mounting position The device is mounted on standard mounting rails according to EN x7,5/15. The device must be mounted vertically in such a way that the input terminals and the output terminals are at the top to ensure correct cooling. A clearance of at least 20 mm should be maintained above and below the device. No space is required at the side Figure 4-1 Output current in the standard mounting position Figure Mounting height derating For details, see Section Ambient conditions (Page 45) Operating Instructions, , C98130-A7560-A
20 Mounting position, mounting clearances 4.2 Other mounting positions 4.2 Other mounting positions For mounting positions that deviate from the standard mounting position, derating factors (reduction of the output power or the permissible ambient temperature) must be observed in accordance with the following diagrams. Note In the case of mounting postilions that deviate from the standard mounting position, reduced mechanical resistance of the devices against vibration and shock must be expected. Particularly when installing on a vertically fastened standard mounting rail, additional measures may be required, e.g. to prevent the device from slipping on the standard mounting rail Figure 4-3 Mounting position (1) Figure 4-4 Mounting position (2) 20 Operating Instructions, , C98130-A7560-A
21 Mounting position, mounting clearances 4.2 Other mounting positions Figure 4-5 Mounting position (3) Figure 4-6 Mounting position (4) Operating Instructions, , C98130-A7560-A
22 Mounting position, mounting clearances 4.2 Other mounting positions 22 Operating Instructions, , C98130-A7560-A
23 Installation 5 WARNING Hazard due to electric shock Before installation or maintenance work can begin, the system's main switch must be switched off and measures taken to prevent it being switched on again. If this instruction is not observed, touching live parts can result in death or serious injury. 5.1 Line-side connection The power supplies are power packs according. to safety class II (without protective conductor or equivalent without PE). are designed for connection to a 1-phase AC supply network (TN or TT system according to VDE 0100 T 300 / IEC 364-3) with rated voltage 1-phase VAC, 50/60 Hz or to a power supply with VDC. Figure 5-1 Line connection The line supply is connected using terminal L1 and N (see Figure 5-1 Line connection (Page 23)), and must be implemented according to IEC and EN A protective device (miniature circuit-breaker or circuit-breaker) and a disconnection unit for the power supply must be provided. A ground-fault circuit interrupter must not be used as the only protective measure against indirect contact; this applies to the entire supply system that is protected by the residual current operated circuit-breaker. Operating Instructions, , C98130-A7560-A
24 Installation 5.1 Line-side connection Note For operation on a direct voltage network (DC), the plus pole (+) must be connected to L1 and the minus pole ( ) to N. Protection 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Recommended line-side protection Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Miniature circuit-breaker (IEC 898): Characteristic B as of 16 A or characteristic C as of 10 A Other country-specific regulations may have to be observed when installing the device. 24 Operating Instructions, , C98130-A7560-A
25 Installation 5.2 Output-side connection 5.2 Output-side connection The power supplies provide an isolated (= non-grounded) SELV (Safety Extra Low Voltage) output voltage at the output. The output of the power supplies is no-load, overload and short-circuit proof. If an overload occurs, the electronic current limiting function limits the output current to a maximum value (see Section Technical data (Page 27)). Figure 5-2 Connection of the output voltage (example of 6EP1311-1SH13) The output voltage is connected via the + and - terminals at the output of the power supply (see Figure 5-2 Connection of the output voltage (example of 6EP1311-1SH13) (Page 25)). Make sure that the output cables are dimensioned correctly for the maximum output current rms value and fused accordingly. Note When using in conjunction with devices of the protection class I (with protective conductor), a connection must be established between "-" and "PE" with at least 1.5 mm². Operating Instructions, , C98130-A7560-A
26 Installation 5.2 Output-side connection 26 Operating Instructions, , C98130-A7560-A
27 Technical data 6 Note For an AC input voltage, the technical data is applicable for rated input voltage, rated load and +25 C ambient temperature (if nothing else is specified). 6.1 Input 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) Input 1-phase AC or DC Rated voltage V Ue rated / for AC Voltage range / for AC V Input voltage / for DC V Wide-range input Yes Overvoltage 2.3 x Ue rated, 1.3 ms resistance Mains buffering at 40 ms 40 ms 40 ms 40 ms 40 ms Ia rated, min. Mains buffering at Ue = 187 V Rated line frequency 50/60 Hz Line frequency range Hz Input current / at rated 0.36 A 0.71 A 0.53 A 1.13 A 0.63 A value of input voltage 120 V Input current / at rated 0.22 A 0.37 A 3 A 0.61 A 0.33 A value of input voltage 230 V Switch-on current 26 A 50 A 25 A 55 A 25 A limitation (+ 25 C), max. I²t, max. 0.8 A² s 3 A² s 0.8 A² s 3 A² s 0.8 A² s Built-in line-side fuse Internal Protection in the line Recommended miniature circuit-breaker Characteristic B as of 16 A or characteristic C as of 10 A feeder cable (IEC 898) Operating Instructions, , C98130-A7560-A
28 Technical data 6.1 Input 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Input 1-phase AC or DC Rated voltage V Ue rated / for AC Voltage range / for AC V Input voltage / for DC V Wide-range input Yes Overvoltage resistance 2.3 x Ue rated, 1.3 ms Mains buffering at 40 ms 40 ms 40 ms 40 ms Ia rated, min. Mains buffering at Ue = 187 V Rated line frequency 50/60 Hz Line frequency range Hz Input current / at rated 1.24 A 0.7 A 1.22 A 1.95 A value of input voltage 120 V Input current / at rated 0.68 A 0.35 A 0.66 A 0.97 A value of input voltage 230 V Switch-on current 55 A 25 A 46 A 30 A limitation (+ 25 C), max. I²t, max. 3 A² s 0.8 A² s 3 A² s 2.5 A² s Built-in line-side fuse Internal Protection in the line Recommended miniature circuit-breaker Characteristic B as of 16 A or characteristic C as of 10 A feeder cable (IEC 898) Figure 6-1 Mains buffering 28 Operating Instructions, , C98130-A7560-A
29 Technical data 6.2 Output 6.2 Output 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) Output Regulated, isolated DC voltage Rated voltage value 5 V 5 V 12 V 12 V 15 V Ua rated DC Total tolerance, static 3% 3% 3% 3% 3% ± Static line regulation, 0.2% 0.1% 0.1% 0.1% 0.1% approx. Static load regulation, 1.5% 2% 1.5% 1.5% 1.5% approx. Residual ripple peakpeak, 100 mv 100 mv 200 mv 200 mv 200 mv max. Residual ripple peakpeak, 10 mv 15 mv 10 mv 10 mv 10 mv typ. Spikes peak-peak, 100 mv 100 mv 300 mv 300 mv 300 mv max. (bandwidth, approx. 20 MHz) Spikes peak-peak, typ. 20 mv 70 mv 20 mv 70 mv 30 mv (bandwidth, approx. 20 MHz) Setting range V V V V V Product function / Yes output voltage can be adjusted Output voltage setting Using a potentiometer Status display Green LED for output voltage OK Response when No overshoot of Ua (soft start) switching on/off Starting delay, max. 0.5 s 0.5 s 0.5 s 0.5 s 0.5 s Voltage rise, typ. 20 ms 10 ms 10 ms 10 ms 15 ms Rated current Ia rated 3 A 6.3 A 1.9 A 4.5 A 1.9 A Current range 0 3 A A A A A Remark 3 A to +55 C, 2.1 A to +70 C 6.3 A to +55 C, 4.4 A to +70 C 1.9 A to +55 C, 1.3 A to +70 C 4.5 A to +55 C, 3.1 A to +70 C 1.9 A to +55 C, 1.3 A to +70 C Output active power / 15 W 30 W 23 W 50 W 23 W typical Can be connected in parallel to increase the power rating Yes Operating Instructions, , C98130-A7560-A
30 Technical data 6.2 Output Number of devices that can be connected in parallel to increase the power rating, units 6EP1311-1SH03 (5 V / 3 A) 2 6EP1311-1SH13 (5 V / 6.3 A) Output characteristic See Figure 6-3 Output characteristic (Page 31) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Output Regulated, isolated DC voltage Rated voltage value 15 V 24 V 24 V 24 V Ua rated DC Total tolerance, static 3% 3% 3% 3% ± Static line regulation, 0.1% 0.1% 0.1% 0.1% approx. Static load regulation, 1.5% 1.5% 1.5% 1.5% approx. Residual ripple peakpeak, 200 mv 200 mv 200 mv 200 mv max. Residual ripple peakpeak, 10 mv 10 mv 10 mv 30 mv typ. Spikes peak-peak, 300 mv 300 mv 300 mv 300 mv max. (bandwidth, approx. 20 MHz) Spikes peak-peak, typ. 70 mv 20 mv 50 mv 60 mv (bandwidth, approx. 20 MHz) Setting range V V V V Product function / Yes output voltage can be adjusted Output voltage setting Using a potentiometer Status display Green LED for output voltage OK Response when No overshoot of Ua (soft start) switching on/off Starting delay, max. 0.5 s 0.5 s 0.5 s 0.5 s Voltage rise, typ. 15 ms 15 ms 10 ms 15 ms Rated current Ia rated 4 A 1.3 A 2.5 A 4 A Current range 0 4 A A A 0 4 A Remark 4 A to +55 C, 2.8 A to +70 C 1.3 A to +55 C, 0.9 A to +70 C 2.5 A to +55 C, 1.7 A to +70 C 4 A to +55 C, 2.8 A to +70 C Output active power / typical 50 W 30 W 60 W 96 W 30 Operating Instructions, , C98130-A7560-A
31 Technical data 6.2 Output Can be connected in parallel to increase the power rating Number of devices that can be connected in parallel to increase the power rating, units 6EP1352-1SH03 (15 V / 4 A) Yes 2 6EP1331-1SH03 (24 V / 1.3 A) Output characteristic See Figure 6-3 Output characteristic (Page 31) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Figure 6-2 Startup delay/voltage rise Figure 6-3 Output characteristic The device supplies a constant output voltage until the current limit is reached. In the event of an overload, the output current and the output voltage are reduced. The device does not switch off. Operating Instructions, , C98130-A7560-A
32 Technical data 6.3 Efficiency and power loss 6.3 Efficiency and power loss Efficiency at Ua rated, Ia rated, approx. Power loss at Ua rated, Ia rated, approx. 6EP1311-1SH03 6EP1311-1SH13 6EP1321-1SH03 6EP1322-1SH03 6EP1351-1SH03 (5 V / 3 A) (5 V / 6.3 A) (12 V / 1.9 A) (12 V / 4.5 A) (15 V / 1.9 A) 77% 83% 80% 85% 81% 4 W 6 W 5 W 10 W 7 W Efficiency at Ua rated, Ia rated, approx. Power loss at Ua rated, Ia rated, approx. 6EP1352-1SH03 6EP1331-1SH03 6EP1332-1SH43 6EP1332-1SH52 (15 V / 4 A) (24 V / 1.3 A) (24 V / 2.5 A) (24 V / 4 A) 85% 85% 88% 89% 11 W 6 W 8 W 12 W Figure 6-4 Efficiency 6EP1311-1SH03 32 Operating Instructions, , C98130-A7560-A
33 Technical data 6.3 Efficiency and power loss Figure 6-5 Efficiency 6EP1311-1SH Figure 6-6 Efficiency 6EP1321-1SH Figure 6-7 Efficiency 6EP1322-1SH03 Operating Instructions, , C98130-A7560-A
34 Technical data 6.3 Efficiency and power loss Figure 6-8 Efficiency 6EP1351-1SH Figure 6-9 Efficiency 6EP1352-1SH Figure 6-10 Efficiency 6EP1331-1SH03 34 Operating Instructions, , C98130-A7560-A
35 Technical data 6.3 Efficiency and power loss Figure 6-11 Efficiency 6EP1332-1SH Figure 6-12 Efficiency 6EP1332-1SH52 Operating Instructions, , C98130-A7560-A
36 Technical data 6.4 Closed-loop control 6.4 Closed-loop control Dyn. mains compensation (Ue rated ±15%) Dyn. load compensation (Ia: 10/90/10%), Ua ± typ. Load step regulation time 10 to 90%, typ. Load step regulation time 90 to 10%, typ. 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 0.2% 0.2% 0.2% 0.2% 0.2% 3% 3% 3% 4% 2.8% 2 ms 2 ms 1 ms 1 ms 1 ms 2 ms 2 ms 1 ms 1 ms 1 ms Dyn. mains compensation (Ue rated ±15%) Dyn. load compensation (Ia: 10/90/10%), Ua ± typ. Load step regulation time 10 to 90%, typ. Load step regulation time 90 to 10%, typ. 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) 0.2% 0.2% 0.2% 0.2% 3% 1% 2% 1.5% 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms 36 Operating Instructions, , C98130-A7560-A
37 Technical data 6.5 Protection and monitoring 6.5 Protection and monitoring Output overvoltage protection 6EP1311-1SH03 6EP1311-1SH13 (5 V / 3 A) (5 V / 6.3 A) Yes, according to EN EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) Current limitation, typ. 3.8 A 8.2 A 2.8 A 5.8 A 2.7 A Property of the Yes output/short-circuit proof Short-circuit protection Constant current characteristic Continuous shortcircuit current / rms value / maximum 5 A 10 A 3.6 A 7 A 3.6 A 6EP1351-1SH03 (15 V / 1.9 A) Output overvoltage protection 6EP1352-1SH03 6EP1331-1SH03 (15 V / 4 A) (24 V / 1.3 A) Yes, according to EN EP1332-1SH43 (24 V / 2.5 A) Current limitation, typ. 5.7 A 1.7 A 3.3 A 5.2 A Property of the Yes output/short-circuit proof Short-circuit protection Constant current characteristic Continuous shortcircuit current / rms value / maximum 7 A 2.4 A 4.8 A 7.9 A 6EP1332-1SH52 (24 V / 4 A) 6.6 MTBF 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Mean Time Between Failures According to SN29500 > h at 40 C, rated load, 24-h operation Operating Instructions, , C98130-A7560-A
38 Technical data 6.7 Mechanical system 6.7 Mechanical system 6EP1311-1SH03 (5 V / 3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1331-1SH03 (24 V / 1.3 A) screw-type terminal 6EP1311-1SH13 (5 V / 6.3 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1332-1SH43 (24 V / 2.5 A) Connection system Connections / line supply L, N: 1 screw terminal each for (2.5) mm² solid (finely stranded) Connections / output +, -: 2 screw terminals each for (2.5) mm² solid (finely stranded) Connections / auxiliary - contacts Width of the housing 54 mm 72 mm 90 mm Height of the housing 90 mm 90 mm 90 mm Depth of the housing 52.6 mm 52.6 mm 52.6 mm Installation width 54 mm 72 mm 90 mm Mounting height 130 mm 130 mm 130 mm Weight, approx kg 0.25 kg 0.34 kg Product feature of the Yes housing / housing that can be lined up next to one another Type of mounting / panel mounting Type of mounting / rail mounting Type of mounting / S7-300 rail mounting Mounting No Yes No Can be snapped onto standard EN x7,5/15 mounting rails 6EP1332-1SH52 (24 V / 4 A) 6.8 Accessories No accessories. 38 Operating Instructions, , C98130-A7560-A
39 Technical data 6.9 Dimension drawing 6.9 Dimension drawing See Section Dimensions and weight (Page 14) CAD data that can be downloaded from the Internet: 6EP1311-1SH03 ( 6EP1311-1SH13 ( 6EP1322-1SH03 ( 6EP1321-1SH03 ( 6EP1351-1SH03 ( 6EP1352-1SH03 ( 6EP1331-1SH03 ( 6EP1332-1SH43 ( 6EP1332-1SH52 ( Operating Instructions, , C98130-A7560-A
40 Technical data 6.9 Dimension drawing 40 Operating Instructions, , C98130-A7560-A
41 Safety, approvals, EMC Safety 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Primary/secondary galvanic isolation Yes Galvanic isolation SELV output voltage Ua according to EN and EN Protection class Class II (without protective conductor) Degree of protection (EN 60529) IP20 Test voltage See Table 7-1 Test voltage (Page 42) Operating Instructions, , C98130-A7560-A
42 Safety, approvals, EMC 7.2 Test voltage 7.2 Test voltage Figure 7-1 Test voltage diagram Only the manufacturer can perform the type test and production test; users can also perform the field test. Preconditions for performing the field test: Test (A) Connect the input terminals to one another Connect the output terminals to one another Table 7-1 Test voltage Type test Production test Field test Test time Prim sec (A) 60 s 4200 VDC 60 s 3000 VAC 1 s 2200 VDC 1 s 1500 VAC 1 s 2200 VDC 1 s 1500 VAC Remark: Tripping current for DC measurement: 0 ma Tripping current for AC measurement: <100 ma 42 Operating Instructions, , C98130-A7560-A
43 Safety, approvals, EMC 7.3 Certifications 7.3 Certifications Certifications 6EP1311-1SH03 (5 V / 3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1332-1SH52 (24 V / 4 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) CE marking Yes (2004/108/EG and 2006/95/EG) UL/cUL approval culus-listed (UL 508, CSA C22.2 No.107.1), File E curus-recognized (UL60950, CSA C22.2 No ) File E culus-listed (UL 508, CSA C22.2 No.107.1), File E curus-recognized (UL60950, CSA C22.2 No ) File E NEC class2 (UL 1310) FM Class I, Div. 2, Groups ABCD; T4 CB scheme IEC Explosion protection ATEX II 3G Ex na IIC T3 ANSI/ISA SEMI F47 compliance V IEC Marine approval Germanischer Lloyd (GL) 6EP1352-1SH52: Cert. No.: HH All other types: Cert. No.: HH ABS, DNV, LRS, BV Operating Instructions, , C98130-A7560-A
44 Safety, approvals, EMC 7.4 EMC 7.4 EMC 6EP1311-1SH03 (5 V / 3 A) 6EP1332-1SH52 (24 V / 4 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) Generic standards EN Immunity for industrial environments EN Emission for residential areas Electrostatic discharges EN kv contact, 8 kv air 6 kv contact, 8 kv air Electromagnetic fields EN MHz 10 V/m MHz 3 V/m MHz 1 V/m MHz 10 V/m MHz 3 V/m MHz 1 V/m High-speed transient disturbance variables (burst) EN kv on line connections 2 kv at DC output 4 kv on line connections 2 kv at DC output Power surges EN kv symmetrical on line connections 4 kv asymmetrical on line connections 500 V symmetrical/asymmetrical on DC output cables 2 kv symmetrical on line connections 4 kv asymmetrical on line connections 500 V symmetrical/asymmetrical on DC output cables High-frequency fields EN V; MHz 10 V; MHz Voltage dips EN % for 20 ms 60% for 200 ms 30% for 500 ms 100% for 20 ms 60% for 200 ms 30% for 500 ms Voltage interruptions EN % for 5000 ms 100% for 5000 ms Emitted interference EN Class B Class B Line harmonics limitation Not applicable EN Operating Instructions, , C98130-A7560-A
45 Ambient conditions 8 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Ambient temperature C with natural convection Tested according to: EN cold EN dry heat EN humid heat, constant EN temperature change Transport and storage temperature C Tests (packed for shipping) according to: EN cold EN dry heat EN humid heat, cyclic Humidity class Mechanical stressing in operation Climate class 3K3 according to EN 60721, without condensation Tested according to: EN vibration, test Fc 7 mm deflection in the range 5-9 Hz 2 g acceleration in the range Hz EN shock, test Ea Acceleration 150 m/s 2, test duration 11 ms Operating Instructions, , C98130-A7560-A
46 Ambient conditions 6EP1311-1SH03 (5 V / 3 A) 6EP1311-1SH13 (5 V / 6.3 A) 6EP1321-1SH03 (12 V / 1.9 A) 6EP1322-1SH03 (12 V / 4.5 A) 6EP1351-1SH03 (15 V / 1.9 A) 6EP1352-1SH03 (15 V / 4 A) 6EP1331-1SH03 (24 V / 1.3 A) 6EP1332-1SH43 (24 V / 2.5 A) 6EP1332-1SH52 (24 V / 4 A) Damaging gases Tested according to: EN Sulfur dioxide: 10 cm 3 /m 3, 4 days EN Hydrogen sulfide: 1 cm 3 /m 3, 4 days Atmospheric pressure Operation: hpa ( m) For operation at altitudes of 2000 m up to 6000 m above sea level: output must be derated by -7.5% / 1000 m or the ambient temperature must be reduced by 5 K / 1000 m see Figure 4-2 Mounting height derating (Page 19) Overvoltage category: III up to 2000 m (EN 50178) II from 2000 m up to 6000 m (EN 50178) Storage: hpa ( m) 46 Operating Instructions, , C98130-A7560-A
47 Applications Parallel connection to increase power rating To enhance performance, two power supplies of the same type can be galvanically connected in parallel. The following must be observed: The cables connected to each power supply at terminals "+" and "-" must have identical lengths and the same cable cross-sections (or the same impedance) up to a common external network junction (terminal strip) if possible. The parallel-switched power supplies must be switched on simultaneously with a common switch in the mains supply line (e.g. with the main switch available in control cabinets). The output voltages measured in no-load operation for the power supplies that are not yet connected in parallel should not deviate more than a maximum of 0.2%. This usually corresponds to the factory setting. If the output voltage is changed, you should connect the "-" terminals and then, in no-load operation, measure the voltage difference between the "+" terminals that have not yet been connected. The voltage difference should not exceed 0.2%. + - Figure 9-1 Parallel connection, correct and incorrect Operating Instructions, , C98130-A7560-A
48 Applications 9.1 Parallel connection to increase power rating NOTICE Protective circuit for the parallel connection of more than two power supplies For connection of more than two power supplies in parallel, additional measures must be taken to prevent high backward feeding currents in the event of a secondary device fault. For this purpose, a suitable protective circuit (e.g. decoupling diode or DC-conform circuit-breaker) must be installed between each "+" terminal of the power supply and the common connection point. 48 Operating Instructions, , C98130-A7560-A
49 Applications 9.2 Parallel connection for redundancy 9.2 Parallel connection for redundancy The parallel switching of several power supplies of the same type for redundancy is required when the demands for reliability of the supply are particularly high. If a component in the redundant supply fails, the power supply for the loads must be fully accommodated by the remaining component. It is therefore important when dimensioning the system to make sure that n+1 redundant switched power supplies can handle the total power requirement of the remaining n power supplies. To prevent loading of the remaining power supplies in the event of a secondary-side error when one power supply fails, the respective "+" terminals of the power supplies must be decoupled via diodes. Note For a high reliability of the supply, it is recommended that the redundant switched power supplies are fused separately on the line-side and, if possible, be connected to different power supply networks. Figure 9-2 Parallel connection for redundancy Operating Instructions, , C98130-A7560-A
50 Applications 9.3 Series connection for increased voltage 9.3 Series connection for increased voltage To achieve a higher output voltage, two power supplies of the same type can be connected in series. In this case, connect the "-" terminal of the first power supply to the "+" terminal of the second power supply. The "+" terminal of the first power supply and the "-" terminal of the second power supply are routed to the load. Depending on grounding point of the secondary output voltage, voltages of +2 UA, ±UA or - 2 UAcan be implemented. In the case of asymmetric load distribution, it is not possible to ensure correct functionality. WARNING SELV is not guaranteed in the case of a fault When connecting two power supplies in series, the continuous, permissible SELV voltage of a maximum of 60 VDC according to EN cannot be guaranteed in the case of a fault. Figure 9-3 Series connection 9.4 Protection against short-time voltage dips During a drop in the primary-side supply voltage, the power supplies still maintain the output voltage over a short millisecond period (see Section Technical data (Page 27)). 50 Operating Instructions, , C98130-A7560-A
51 Environment 10 The device is in conformance with RoHS. As a rule, only non-silicon precipitating materials are used. Disposal guidelines Packaging and packaging aids can and should always be recycled. The product itself may not be disposed of as domestic refuse. Operating Instructions, , C98130-A7560-A
52 Environment 52 Operating Instructions, , C98130-A7560-A
53 Service and support 11 Technical support Technical support for all IA/DT products can be accessed through the following communication channels: Phone: + 49 (0) (mailto:[email protected]) Internet: Online support request form ( Technical documentation on the Internet Operating instructions and manuals for SITOP are available in the Internet: Operating instructions/manuals ( SITOP power supply homepage General news about our power supplies is available in the Internet at the SITOP homepage: SITOP ( Information material SITOP information can be downloaded from the Internet: Information and download center ( CAx data 2D/3D data and circuit diagram macros can be downloaded from the Internet: Siemens image database ( Request all CAx data via the CAx download manager: CAx shopping cart ( SITOP Selection Tool Simply and quickly select the optimum the power supply or DC-UPS: SITOP Selection Tool ( Online catalog and ordering system The online catalog and the online ordering system are available through the Industry Mall homepage: Industry Mall ( Operating Instructions, , C98130-A7560-A
54 Service and support Contact persons If you have any questions regarding the use of our products, then contact the Siemens contact person in your regional Siemens sales office. You can find these addresses as follows: On the Internet ( In Catalog CA Operating Instructions, , C98130-A7560-A
LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2
Overview Description, device design, dimension drawing 1 Power supply Operating Instructions Mounting/Disassembly 2 Mounting position, installation clearances 3 Installation 4 Applications 5 Technical
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
PHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA
Highlights & Features Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed Designed for Class I Div. 2
CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA
Highlights & Features Universal AC input voltage Power will not de-rate for the entire input voltage range Power Boost of 150% for 3 seconds Full corrosion resistant aluminium chassis SEMI F47 certified
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.
SITOP power supply Technical data SITOP Power Supply Answers for industry. Selection table SITOP power supplies Input voltage Output current modular smart LOGO!Power Special design, SIMATIC design Others
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
APD336.221/.421 3 Outputs 19" DC/DC Converter, 50 Watt
APD336.221/.421 3 Outputs 19" DC/DC Converter, 50 Watt High efficiency: 79% (@ 48V) DCin wide range: 9...36V or 18...72V DC 8 HP plug in width H15 standard pinout Active inrush current suppression Voltage
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
7 - Phaseo power supplies and transformers
/0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10
ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Power Supplies 3. SDN-C Compact DIN Rail Series
Power Supplies 3 SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
S-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules
SIMATIC S7-300 and M7-300 Programmable Controllers Module Specifications Reference manual This manual is part of the following documentation packages with order nos: S7 300 Programmable Controller: 6ES7
Industrial Power Supplies
TSP-Series Innovative and Powerful Features! Rugged metal case for harsh industrial environments Shock and vibration proof Worlwide Safety approval package. ATEX certification tested in accordance to IECEX
ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000
Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level
SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01
SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal
SITOP UPS1600 / UPS1100. SITOP power supply SITOP UPS1600 / UPS1100. Overview. Safety information. Description, device design, dimension drawing 2
Overview Safety information 1 SITOP power supply Operating Instructions Description, device design, dimension drawing 2 Engineering 3 Mounting/removal 4 Mounting position, mounting clearances 5 Installation
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
USB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address