Probe Needle Wear and Contact Resistance



Similar documents
Low and Stable Contact Resistance With Reduced Cleaning......A Paradigm Shift

Comprehensive Approach to Control Contact Resistance Instability and Improve First Pass Yield of Bumped Devices

Vertical Probe Alternative for Cantilever Pad Probing

Wafer Placement Repeatibility and Robot Speed Improvements for Bonded Wafer Pairs Used in 3D Integration

Lapping and Polishing Basics

TechCut 4 Precision Low Speed Saw

1.Introduction. Introduction. Most of slides come from Semiconductor Manufacturing Technology by Michael Quirk and Julian Serda.

Right Angle Grinder USA MADE FLAP DISCS

3.8 HSP (High Solids Polyurethane)

Choosing a Stencil. By William E. Coleman, Ph.D. and Michael R. Burgess

Tableting Punch Performance Can Be Improved With Precision Coatings

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

Screen Melts. Introduction. Selecting Screen Material. Prefire Before Using. Spalling. Kiln Shelf

FABRICATION 2011 SERVICES TECHNOLOGIES CAPABILITIES INDUSTRY

RC Scrub R. High Performance Test Socket Systems for Micro Lead Frame Packages

Dynamic & Proto Circuits Inc. Corporate Presentation

Card electrical characteristic, Parallelism & Reliability. Jung Keun Park Willtechnology

Wafer Level Testing Challenges for Flip Chip and Wafer Level Packages

COATED CARBIDE. TiN. Al 2 O 3

Evaluating Surface Roughness of Si Following Selected Lapping and Polishing Processes

Chip-on-board Technology

How to Pre-empt a Significant Profit Drain: Nozzle Wear

General Guidelines for Building Aluminum Production Injection Molds

Directory chapter 04

SURFACE TREATMENT BOND TEST

Good Boards = Results

Automotive Electronics Council Component Technical Committee

Actual vs. Programmed Overtravel for Advanced Probe Cards

SURFACE MOUNT CERMET TRIMMERS (SINGLE TURN) Rotor. Wiper. Cover. Pin S T - 2 T A Ω ( )

WOOD WEAR TESTING USING TRIBOMETER

Sheet Resistance = R (L/W) = R N L

Connectivity in a Wireless World. Cables Connectors A Special Supplement to

C3 Coating: Solution for IC Testing (Reduction of Solder Migration)

Plastic Injection Molds

INTERTECH EDM Technology To cut PCD Materials. Presented by. Eric Ostini Product Manager +GF+ Agie Charmilles Group

The "DAVID" Steam Engine By Alan Marconett Hobbit Engineering

Laser sintering of greens compacts of MoSi 2

Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth

Understanding the Wire EDM Process

Advantages of Precision Resistance Networks for use in Sensitive Applications

Why Plastic Flows Better in Aluminum Injection Molds

Automated Contact Resistance Tester CR-2601

8-bit Atmel Microcontrollers. Application Note. Atmel AVR211: Wafer Level Chip Scale Packages

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

Lecture 030 DSM CMOS Technology (3/24/10) Page 030-1

HOT BAR REFLOW SOLDERING FUNDAMENTALS. A high quality Selective Soldering Technology

Advanced Technologies and Equipment for 3D-Packaging

NANO INDENTERS FROM MICRO STAR TECHNOLOGIES

Technical Info Sheet. Ionic contamination testing in a no-clean soldering process. Scope

CIRCUITS AND SYSTEMS- Assembly and Printed Circuit Board (PCB) Package Mohammad S. Sharawi ASSEMBLY AND PRINTED CIRCUIT BOARD (PCB) PACKAGE

MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.

This paper describes Digital Equipment Corporation Semiconductor Division s

Aeroflex Solutions for Stacked Memory Packaging Increasing Density while Decreasing Area

Mounting Instructions for SP4 Power Modules

Advanced VLSI Design CMOS Processing Technology

Flex Circuit Design and Manufacture.

3D Printed Injection Molding Tool ("PIMT") Guide. Objet Ltd.

LEADER IN CUTTING TECHNOLOGY

SEGMENTED WOODTURNING

Winbond W2E512/W27E257 EEPROM

Dry Film Photoresist & Material Solutions for 3D/TSV

Selective Soldering Defects and How to Prevent Them

Die casting Figure M2.3.1

CASE STUDY: SCREEN PRINTING SOLUTIONS FOR SMALL DIE & PRECISION ALIGNMENT CHALLENGES

8.0. The most complete image analysis solution CLEMEX VISION PE. Intelligent systems designed for multiple or complex applications

Customer Service Note Lead Frame Package User Guidelines

Cutting Tool Materials

Solutions without Boundaries. PCB Surface Finishes. Todd Henninger, C.I.D. Sr. Field Applications Engineer Midwest Region

Evaluation of New Probe Technology on SnAg and Copper Bumps

FEATURES AND BENEFITS OF DIFFERENT PLATINUM ALLOYS. Kris Vaithinathan and Richard Lanam Engelhard Corporation

Development of High-Speed High-Precision Cooling Plate

Phosphoric Acid Anodized Aluminum Honeycomb

Saw Tooth Design and Tipping Materials

Coating Technology: Evaporation Vs Sputtering

Injection moulding and modelling on a micro scale

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Compliant Terminal Technology Summary Test Report

Flanged and Butt-= Weld Type

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

University of Portland School of Engineering LABORATORY OUTLINE: TENSILE TESTING OF STEEL & ALUMINUM ALLOYS (ASTM E8)

CHAPTER 5. OVERVIEW OF THE MANUFACTURING PROCESS

Chapter 4 and 5 solutions

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

CHAPTER 6 WEAR TESTING MEASUREMENT

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: Solon Road FAX:

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Silicon-On-Glass MEMS. Design. Handbook

Technical Data Sheet February 2014

Molded. By July. A chip scale. and Omega. Guidelines. layer on the silicon chip. of mold. aluminum or. Bottom view. Rev. 1.

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Hand Soldering Basics

New Methods of Testing PCB Traces Capacity and Fusing

, Yong-Min Kwon 1 ) , Ho-Young Son 1 ) , Jeong-Tak Moon 2 ) Byung-Wook Jeong 2 ) , Kyung-In Kang 2 )

Failure Analysis (FA) Introduction

A. Work on this project shall consist of, but is not limited to, the following:

OLUTIONS. ROCTEC Composite Carbide ABRASIVE WATERJET NOZZLES

h e l p s y o u C O N T R O L

Transcription:

Probe Needle Wear and Contact Resistance Jerry J. Broz, Ph.D. Research and Development Advanced Probing Systems, Inc. Boulder, Colorado Reynaldo M. Rincon Probe Coordinator Texas Instruments, Inc. Dallas, Texas 1

Participants SEMATECH Probes PTAB Probe Needles Advanced Probing Systems, Inc. Probe Cards CerProbe Corporation JEM America Micro-Probe, Inc. Probe Technology Corporation Wentworth Laboratories Testing Facilities Applied Precision, Inc. (John Strom, Kenneth Sokol, Bryce Ekstrom) Sandia National Laboratories (David Monroe, Scot Swanson) 2

No Benchmarking Research Objectives Probe card construction was specified for this study Overall performance between cards WAS NOT compared Quantify abrasive cleaning effects Probe tip wear due to burnishing Appropriate cleaning procedures Evaluate probe needle wear behavior Room and elevated temperature touchdown testing Appropriate probe needle metal system 3

Research Focus SEMATECH 1997 Development Roadmap Room temperature (hot chuck at 30 o C) Elevated temperature (hot chuck at 85 o C) Practice for probe card cleaning 3-µm grit burnishing pad (hot chuck at 30 o C) Practices used for 70 µm pitch probe cards Tungsten and tungsten-rhenium probe materials 0.005 and 0.007 diameter probe needles Three-tiered epoxy ring probe cards For this presentation only Tier 1 behavior will be discussed 4

Testing Environments Abrasive cleaning Room temperature(30 o C) High temperature (85 o C) Low forcing current (50 ma) Probe Needles Focus on Primary Probe Needle Properties Material Probe and probe tip diameter Etch length 5

Probe Card Consistent Secondary Probe Needle Variables Balanced contact force Overtravel Beam angle Tip angle Etc. 6

Probe Needle Specifications Isolinear Probe Needles Known probe tip geometry Tip diameter and length mathematically related Probe Needle 5-mil Diameter Etch Length (inch) 0.070 0.080 0.090 Etch Rate (deg) 4.1 3.6 3.2 Finish Tungsten (W): Matte Tungsten-Rhenium (WRe): Polish 7-mil Diameter 0.090 0.100 0.110 4.5 4.0 3.6 Tungsten (W): Matte Tungsten-Rhenium (WRe): Polish 7

Probe Card Specifications Board Style: HP 4062, 4" PCB Probe Depth: 150 mils Test Temperature: 25 o to 85 o C Ring Material: Ceramic Tip Diameter: 1.2 ± 0.1 mils Overdrive: 3 mils Tip Shape: Flat Planarity: ± 0.5 mils Tip Angle:. 103 ± 3 deg. Alignment: ± 0.5 mils Beam Angle: 10 deg. Leakage: 100 na Pad Material: Aluminum Contact Resistance 1.5 to 2.0 Ω Fanout: 0 ± 3 deg. Gram Force: 2 grams/mil BCF: ± 20% 8

60-Pin Configuration 1800 1600 Tungsten 5-mil diameter 1400 Y - Location (µm) 1200 1000 800 600 Tungsten 7-mil diameter TIER 1 TIER 2 TIER 3 Tungsten-Rhenium 7-mil diameter 400 200 Tungsten-Rhenium 5-mil diameter 0 0 200 400 600 800 1000 1200 1400 1600 1800 X - Location (µm) 9

Probe Card 10

Abrasive Testing Test Wafers 6-inch scrap metallized wafer 3-µm abrasive pad, i.e. the pink stuff Touchdown Testing 8-inch metallized wafer manufactured by SEMATECH Titanium-nitride substrate 1-µm thick Aluminum layer 11

Stepping Pattern 12

Test Equipment ElectroGlas-4080 Tester with Hot Chuck Burnishing pad touchdown testing Metallized wafer touchdown testing at 30 o C and 85 o C HP4062 Parametric 48-Channel Analyzer On-line contact resistance measurements Applied Precision PRVX 2 -Probe Card Analyzer Probe tip diameter Contact resistance Balanced contact force 13

Touchdown Test Flow 3-µm Abrasive Pad 3.0-mil overtravel, linear mode, double-touchdown mode PRVX 2 metrology performed after 0, 7.5K, and 15K touchdowns Contact resistance Tip diameter Metallized Wafer at 30 o and 85 o C 3.0 mil overdrive, double-touchdown mode (8 touchdowns/second) Contact resistance measurements every 5K touchdowns PRVX 2 metrology performed after 0, 250K, and 500K touchdowns Contact resistance Tip diameter 14

3-µm Abrasive Pad 15

3-µm Abrasive Pad Tungsten vs. Tungsten-Rhenium Abrasive particles are considerably harder than both probe materials No significant differences between materials in amount of tip length removed 5-mil vs. 7-mil Diameter Probe Needles Amount of tip length removed from the 5-mil probes was greater than that of the 7-mil probes Contact Resistance Measurements Baseline ( as delivered ) and post-touchdown C RES values were higher than expected Cleaning was performed and C RES values were considerably reduced Contamination on probe tip surface - tungsten-oxide? other residue? 16

3-µm Abrasive Pad Approximate Wear Rates Changes in tip geometry occur with each touchdown Wear rate = f(overtravel, scrub length, BCF, etch length, contact materials) Conservative first approximation of abrasive wear rates Estimated amount of material removed 0 to 7.5K Estimated amount of material removed 0 to 15K 5-mil diameter 38 Å per touchdown 52 Å per touchdown 7-mil diameter 35 Å per touchdown 48 Å per touchdown 17

Al-Wafer at 30 o and 85 o C Probe Tip Wear Characteristics Isolinear taper shape was used to calculate average tip length changes Contact Resistance Box plots were used to show the range and mean of C RES values for material 18

19

20

21

Al-Wafer at 30 o C Wear and C RES 7-mil WRe-probes demonstrated significantly lower C RES values than 7- mil W-probes Differences between the 5-mil probes were not as significant Microhardness values of the probes W005 WRe005 W007 WRe007 VHN (kg/mm 2 ) 738 ± 47 736 ± 33 718 ± 45 804 ± 23 C RES on Virgin vs. Scrubbed Aluminum C RES response of the WRe-probes unaffected by wafer surface condition On the other hand, the W-probes demonstrated marked differences 22

23

24

25

Al-Wafer at 85 o C Wear and C RES Reductions in WRe-probe tip lengths were significantly less than those of the W-probes Overall, the WRe-probes demonstrated lower and more stable C RES behavior Temperature Effects Metallurgical fact - materials soften with increased temperature Rhenium stabilizes small diameter wire grain structure at high temperatures Grain structure affects hardness and wear characteristics of probe needles The softening rate of WRe-probes differs from than that of W-probes 26

Application of Results A Thought Experiment Probe card required to test 500K die Testing performed at room and high temperature Triple Hit cleaning every 100 die 7.5K cleaning touchdowns after 250K die 15K cleaning touchdowns after 500K die Can an estimate be made of the probe service life? Reduction in tip length Increase in tip diameter 27

28

29

Summary TIER 1 ONLY No Benchmarking Probe Needle Wear Abrasive Cleaning Cleaning pad material is dramatically harder than both probe materials No significant differences in the amount of tip length removed Wear rate first approximations based on 15K cleanings: 52 and 48 Å per touchdown for 5-mil and 7-mil probes, respectively Wear rate = f(overtravel, scrub length, BCF, etch length, contact materials) 30

Probe Needle Wear Aluminum-wafer at 30 o C Summary Difference in wear behavior were observed for the 7-mil probes and not as severe for the 5-mil probes Wear rate first approximations based on 500K touchdowns: 700, 560, 600, and 380 Å per 1K-touchdowns for W005, WRe005, W007, and WRe007, respectively Hardness values of the 7-mil WRe-probes were significantly higher than those of the W-probes The 5-mil probes had comparable hardness values and hence demonstrated similar wear characteristics As the diameter of the probe needles decreases, the hardness of tungsten and tungsten-rhenium become similar 31

Probe Needle Wear Al-Wafer at 85 o C Summary Wear differences were exacerbated by the higher temperature Wear rate first approximations based on 500K touchdowns: 1100, 700, 900, and 560 Å per 1K-touchdowns for W005, WRe005, W007, and WRe007, respectively Increased temperature results in a thicker Al-oxide layer and a reduction in the probe needle hardness Changes of the WRe-probe tip lengths were significantly less than those of the W-probes Alloying with rhenium stabilizes the grain structure and hardness at high temperatures The temperature dependent softening of WRe-probes is different than that of W-probes 32

Contact Resistance Al-Wafer at 30 o C Summary C RES consistency of the W-probes was affected by the wafer surface condition W-probes demonstrated higher C RES values on the scrubbed portion WRe-probes demonstrated consistent C RES values regardless of the wafer surface, i.e. virgin vs. scrubbed Al-Wafer at 85 o C C RES variance of all probe needles was greater at higher temperature C RES consistency of the W-probes was affected by the wafer surface condition; but not as dramatically as at room temperature C RES behavior of the WRe-probes was unaffected by the wafer surface condition Overall, the WRe-probes demonstrated lower and consistent C RES values 33

Summary Probe Service Life Estimates First approximations of the service life for Tier 1 were made Differences in probe tip wear are over-shadowed by abrasive cleaning Service Life = f(temperature, current, overtravel, scrub length, BCF, cleaning frequency, and contact material) The results indicate that WRe-probes would provide a longer service life than W-probes at high temperatures Benefits of Tungsten-Rhenium At room temperature, WRe-probes provide C RES consistency with slight improvements in wear that over-shadowed by abrasive cleaning At high temperature, WRe-probes provide C RES consistency and significant improvements in wear 34

Additional Observations Side Bar C RES values of probes that never touched a wafer were higher than expected Cleaning was performed and C RES values were considerably reduced Contamination on probe tip surface - tungsten-oxide? other residue? who really knows? Future Work Analysis of Tier 2 and Tier 3 behavior 35