POWR PULS VLVS pilot threaded or Quick Mount 3/4 to 1 1/2 N 2/2 Series 353 TURS The piston cartridge pulse valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to produce reliable and economical operation The angle bodies and special piston cartridge result in unique operating features required for dust collector service applications The high quality polyacetal (POM) piston cartridge guarantees a long operating life and a large temperature range The design with Quick Mount s eliminates the time consuming thread cutting and sealing resulting in maximum flexibility while the valve will be anchored to the pipes Valves can be supplied according to TX irective 94/9/ for non-electrical equipment by using suffix The components satisfy all relevant directives eneral ifferential pressure (PS) mbient temperature range - bar [1 bar = 100kPa] -20 to +85 fluid temperature range (TS) piston air -20 to +85 POM (polyacetal) ONSTRUTION ody onnet Quick Mount clamps olts Sealings Piston/cartridge luminium luminium Steel Steel NR (nitrile) POM (polyacetal) / NR (nitrile) X003-2009/R8 PILOT SOLNOI VLVS (2/2 N function) main pulse valve 353810 353820 S353710 S353720 S353810 S353820 pilot SPIITIONS (mm) 3,6 recommended executions manifold pilot valves in a box (IP65) pilot box series 110 2 to 12 pilots single pilot valves (IP20) series 257 operating pressure flow differential (bar) pipe pilot coefficient max. (PS) Kv min. air (mm) (m 3 /h) (l/min) ~/= standard TX dust II2/ (*) - Threaded pipe 3/4 1 11/2 20 25 40 (Ø) - Quick Mount on inlet 3/4 1 11/2 20 25 40 14 23 14 23 (Ø) - Quick Mount on inlet & outlet 3/4 1 11/2 20 25 40 14 23 233 383 768 233 383 768 233 383 768 353810 353820 353830 S353810 S353820 S353830 S353710 S353720 S353730 353810 353820 353830 S353810 S353820 S353830 S353710 S353720 S353730 Quick Mount clamps - - - 117-281 117-282 117-290 117-281 117-282 117-290 X003-17
VLVS SRIS 353 OPTIONS Pilot boxes containing 2 to 12 pilot valves. Pilot valves can be equipped with explosionproof solenoids for hazardous locations according to TX and national standards. dditional Quick Mount clamps for outlet, see Specifications table. INSTLLTION The valves can be mounted in any position without affecting operation. Pipe identifier is: *= combination thread according to ISO 228/1 and ISO 7/1 or Ø for Quick Mount. or Quick Mount types tightness is achieved by the O-ring sealing on the pipes (3/4"=Ø26,4 to 27,4 and 1"=Ø33,2 to 34,2 and 1 1/2"=Ø47,8 to 48,8) according to ISO 4200. When connecting piping or tubing to the in the valve bonnet, the SO pilot valve should be mounted as close as possible to the main pulse valve. onnection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Ø 6 mm O.. is recommended for all installations. Other pipe threads are available on request. Installation/maintenance instructions are included with each valve. Spare parts kit and replacement coils are available. IMNSIONS (mm), WIHT (kg) ig. 1: Threaded type ig. 2: Quick Mount type (inlet only) weight () 353810 () 353820 () 353830 () S353810 () S353820 () S353830 () S353710 () S353720 () S353730 () () construction type ig. 3: Quick Mount type (inlet & outlet) 84 96 121 103 115 1 103 115 1 94 100 127 94 100 127 113 119 153 42 51 60 42 51 60 61 70 86 50 62 71 69 81 97 69 81 97 X003-18 H 39 62 39 62 39 62 112 112 112 0,42 0,53 1,07 0,50 0,59 1,27 0,58 0,65 1,27 ig.1 ig.1 ig.1 ig.2 ig.2 ig.2 ig.3 ig.3 ig.3 X003-2009/R8
PULS VLVS single stage, pilot threaded body or compression fitting 3/4 to 1 1/2 N IN 2/2 Series 353 TURS The diaphragm pulse valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to produce reliable and economical operation The high flow, angle type bodies in combination with the special main diaphragm assemblies give the unique operating features required for dust tcollector service applications Integral compression fittings for fast, easy, secure installation Valves can be supplied according to TX irective 94/9/ for non-electrical equipment by using suffix The valves satisfy all relevant directives NRL ifferential pressure (PS) mbient temperature range 5 - bar [1 bar = 100kPa] -20 to +85 fluids ( ) temperature range (TS) diaphragm ( ) air -40 to +85 TP (3/4 und 1) -20 to +85 R (1 1/2) MTRILS IN ONTT WITH LUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified ody luminium / Stainless steel 316L Spring Stainless steel iaphragm TP (thermoplastic polyester elastomer oder R (chloroprene) Ø P14242-2012/R01 PILOT SOLNOI VLVS (2/2 N function) main pulse valve 353041 353-055 353042 353-056 353045 353-066 pilot SPIITIONS pipe (mm) 3.6 1/4 5,6 pilot recommended executions manifold pilot valves in a box (IP 65) pilot box series 110 2 to 12 pilots pilot box series 20 4 to 6 valves 1/4 flow coefficient Kv single pilot valves (IP20) series 257 series 262 / 272 operating pressure differential (bar) max. (PS) min. air ( ) Ø (mm) (m³/h) (l/min) ~/= aluminium stainless steel 316L - threaded pipe 3/4 24 14 233 5 353041 353130 V 1 27 17 283 5 353042 353131 V 1 1/2 52 768 5 353045 - V Ø - ompression fitting pipe 3/4 24 14 233 5 353-055 - V 1 27 17 283 5 353-056 - V 1 1/2 52 43 717 5 353-066 - V IN PM X003-19
VNTIL URIH 353 OPTIONS Valves can also be supplied with PM (fluoroelastomer) diaphragms and seals. Use the appropriate optional suffix letter for identification Sequential controller for pilot solenoid valves Pilot boxes containing 2 to 12 pilot solenoid valves Pilot solenoid valves can be equipped with explosionproof solenoids for hazardous locations according to TX and national standards INSTLLTION The valves can be mounted in any position without affecting operation Threaded pipe is (ISO 228/1) or compression fitting When connecting piping or tubing to the in the valve bonnet, the SO pilot valve should be mounted as close as possible to the main pulse valve. onnection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Ø 6 mm O.. is recommended for all installations or compression fitting types tightness is achieved by the compressed gasket on the blow tube Other pipe threads are available on request Installation/maintenance instructions are included with each valve Spare parts kits and replacement coils are available IMNSIONS (mm), WIHT (kg) IN ig. 1: Threaded pipe - aluminium ig. 2: ompression type fitting - aluminium weight (1) () 353041-51 89 75 41 65 0,45 ig. 1 353042-51 89 75 41 64 0,4 ig. 1 353045 30 1/4 71 130 136 71 98 1 ig. 1 353-055 - 88 125 75 47 109 0,58 ig. 2 353-056 - 88 124 75 47 129 0,61 ig. 2 353-066 30 1/4 117 1 136 73 161 1,33 ig. 2 353130-51 89 75 41 64 0,92 ig. 3 353131-51 89 75 41 64 0,87 ig. 3 () onstruction type X003-20 ig. 3: Threaded pipe - Stainless steel P14242-2012/R01
PULS VLVS dual stage, pilot threaded body 1 1/2 to 3 or compression fitting Ø 1 1/2 N IN 1 2/2 Series 353 TURS The pulse valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to produce reliable and economical operation The high flow, angle type bodies in combination with the special main diaphragm assemblies give the unique operating features required for dust collector service applications Integral compression fittings for fast, easy, secure installation Valves can be supplied according to TX irective 94/9/ for non-electrical equipment by using suffix The components satisfy all relevant directives eneral ifferential pressure (PS) mbient temperature range 5 - bar [1 bar = 100kPa] -20 to +85 fluids temperature range (TS) diaphragm air -20 to +85 R (chloroprene) Ø ONSTRUTION ody Springs iaphragms luminium Stainless steel R (chloroprene) PILOT SOLNOI VLVS (2/2 N function) main pulse valves 3530 353063 pilot (mm) 3,6 recommended executions manifold pilot valves in a box (IP65) pilot box series 110 2 to 12 valves single pilot valves (IP20) series 257 IN 353048 353049 353-058 1/4 5,6 pilot box series 20 4 to 6 valves 1/4 _ X003-2009/R8 SPIITIONS flow operating pressure pipe coefficient differential (bar) Kv max. (PS) min. air (mm) (m 3 /h) (l/min) ~ /= - Threaded pipe 1 1/2 52 768 5 3530 2 66 1290 5 353048 2 1/2 66 92 1540 5 353049 3 76 170 2833 1,0 6,0 353-058 (1) Ø - ompression fitting pipe 1 1/2 52 43 717 5 353063 (1) Threaded pipe s are external (male thread). standard TX II2/ 3530 353048 353049 353-058 (1) 353063 OPTION PM V V V V V X003-21
VLVS SRIS 353 OPTIONS Valves can also be supplied with PM (fluorelastomer) diaphragms and seal materials. Use the appropriate optional suffix letter for identification Sequential controller for pilot solenoid valves Pilot boxes containing 2 to 12 pilot solenoid valves Pilot solenoid valves can be equipped with explosionproof solenoids for hazardous locations according to TX and national standards INSTLLTION The valves can be mounted in any position without affecting operation Threaded pipe is: = (ISO 228/1) or compression fittings When connecting piping or tubing to the or 1/4 in the valve bonnet, the SO pilot valve should be mounted as close as possible to the main pulse valve. onnection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Ø 6 or Ø 8 mm O.. is recommended for all installations or compression fitting types tightness is achieved by the co mpressed gasket on the blow tube Other pipe threads are available on request Installation/maintenance instructions are included with each valve Spare parts kit and replacement coils are available IMNSIONS (mm), WIHT (kg) H IN H ig.1 Threaded type ig.2 ompression fitting type ig. 3 xternal threaded type 3530 () 353048 () 353049 () 353-058 () 353063 () () construction type H weight 30 30 30 48 30 " 1/4" 1/4" 1/4" " 71 95 95 143 87 130 168 168 240 1 X003-22 136 165 165 192 136 3/8" 3/4" 3/4" 1/2" 3/8" 90 121 121 121 96 H 120 166 166 214 183 1,10 2,60 2,30 3,70 1,43 () ig.1 ig.1 ig.1 ig.3 ig.2 X003-2009/R8
TURS POWR PULS TNK SYSTM (Ø160) pilot 1 Power Pulse Tank System using aluminium profile and end covers with approval according to irective 97/23/ for Pressure quipment ull immersed valve system with special springless piston/diaphragm design offers highest peak pressure and best flow performance operating features required for dust collector applications The high quality TP piston/diaphragm guarantees a long operating life and a large temperature range Possibility to apply different combinations of pitch distances and upto 24 valves asy to connect to other tank systems. Service s for different accessories such as: filter regulator, pressure gauge, safety valve and automatic / manual drain valve Several blow pipe s available, such as: Quick Mount, push-in, hose or threaded N 2/2 Series 355 NRL ifferential pressure (PS) mbient temperature range Tank System volume recommended min. tank volume min. pitch distance maximum length min. pulse time to bar [1 bar = 100 kpa] -20 to +85 0,20 dm 3 per cm tank 10 dm 3 (equals 500 mm tank length) 120 mm 3000 mm 50 ms fluid temperature range (TS) piston/diaphragm air -20 to +100 TP (thermoplastic polyester elastomer) ONSTRUTION Tank dapter/body lipring lamps olts (clamps) Sealings & disc Piston/diaphragm nodized aluminium luminium Stainless steel Stainless steel Stainless steel NR (nitrile) TP (thermoplastic polyester elastomer) ROMMN PILOT VLVS N OXS (2/2 N function) X003-2009/R8 main pulse valve 355N.. 355O.. 355P.. 355Q.. pilot valve (mm) 3,6 pilot valve box (IP65) pilot box series 110 2 to 12 pilots single pilot valve (IP20) US 257001 US 257002 US 257003 X003-23
VLVS SRIS 355 SPIITIONS pipe pilot (mm) (m 3 /h) flow coefficient Kv (l/min) operating pressure differential (bar) min. maximum (PS) air 1" 25 23 384 0. 355... ORRIN INORMTION - for example: 355 N 06 + imension code (specified on next page) 64 52 (1) 3 5 5 N 06 (2) 17 Quick mount with clamps (Ø 33,2-34,2) O 64 52 37 6 valves pilot box Push-in (Ø 33,2-34,2) 12 valves pilot box (1) for a selection of pilot boxes see pages X003-29 to X003-38 (2) specify required of valves between 01 and 24 X003-24 P Q 37 9 Male hose (Ø 33,5-33,9) 34 9 Male threaded (R1") X003-2009/R8
VLVS SRIS 355 ORRIN INORMTION IMNSION O Start distance (min. 110 mm) Standard pitch // (min. 120 mm) eviating pitch // (min. 120 mm) nd distance (min. 110 mm) xample I: imension code for a 4 valves tank system: Operator Remote, pilotbox controlled 24V/ without heating onnection Quick Mount Number of valves 4 pcs Start and nd distance 110 mm Standard pitch 170 mm eviating pitch None atalogue 355N04 imension code 110170 Pilotbox S 110040 24V/ omplete order 355N04 + 110170 xample II: imension code for a 12 valves tank system: Operator onnection Number of valves Start and nd distance Standard pitch eviating pitch atalogue imension code omplete order Remote, controlled with external pilotbox Thread 12 pcs 130 mm 140 mm etween valve 3 and 4 is position ; 180 mm and between valve 7 and 8 is position H; 200 mm 355Q12 130140180H200 355Q12 + 130140180H200 or assistance please consult our website: www.asconumatics.eu IMNSIONS (mm) ig. 1 (front view) 90 36 X003-2009/R8 ig. 2 (side view) 217 174 Ø45,5 52 22 space for: 187 mm 6 pilot valve box 322 mm 12 pilot valve box " Pressure supply 1" Service ¼" 145 258 38 35 110 180 78 140 X003-25
OPTIONS VLVS SRIS 355/353 Special customized executions Pilot boxes containing 2 to 12 pilot valves Separate pilot valves can be equipped with explosionproof solenoids for hazardous locations according to TX (NL) and national standards Separate Quick Mount clamps for outlet ; kit : 132-679 INSTLLTION Tank system can be mounted in any position using the standard brackets integrated in the end cap (M12 bolts recommended) without affecting operation Pipe identifier is: R = according to ISO 7/1, = according to ISO 228/1 or Ø for other outlet s or Quick Mount types tightness is achieved by the O-ring sealing on the pipe (1" = Ø33,2 to 34,2) according to ISO 4200 When connecting piping or tubing to the in the valve bonnet, the SO pilot valve should be mounted as close as possible to the main pulse valve. onnection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Ø 6 mm is recommended for all installations Installation/maintenance instructions are included with each tank system Spare valves, spare parts kits and coils are available SPRT / SPR POWR PULS VLVS TURS - (same as for the tank system) IMNSIONS (mm), WIHT (kg) " 33 99 Ø 99 SPIITIONS pipe () emale threaded (ISO 228/1) 1 353231 weight 0,428 X003-26 1" X003-2009/R8
TNK SYSTM (Ø 8") pilot 1 1/2 TURS Immersion tank system using steel profile and welded end covers with approval according to irective 87/404/ Immersed valve system with special diaphragm design offers highest peak pressure and best flow performance operating features required for dust collector applications The high quality diaphragms are reinforced and wear resistant to guarantee a long operating life, even under harsh conditions Possibility to apply different combinations of pitch distances Service s for different accessories such as: filter regulator, pressure gauge, safety valve and automatic/manual drain valve vailable with hose and threaded blow pipe s N 2/2 Series 357 eneral ifferential pressure (PS) mbient temperature range 5 to 8 bar [1 bar = 100kPa] -10 to +80 fluid temperature range (TS) seal materials air -10 to +80 R (chloroprene) ONSTRUTION Tank onnet olts Sealing & iaphragm Steel, grey luminium Stainless steel NR (nitrile) R (chloroprene) PILOT SOLNOI VLVS (2/2 N function) recommended executions pipe 1 1/2" main pulse valves 357Pxx 357Qxx pilot (mm) 3,6 manifold pilot valves in a box (IP 65) pilot box series 110 2 to 12 valves single pilot valves (IP20) series 257 X003-2014/R01 SPIITIONS pipe flow coefficient Kv operating pressure differential (bar) max. (PS) min air (mm) (m 3 /h) (l/min) ~ / = hose threaded 8" Tank System 1 1/2" 40 768 5 8 357Pxx (1) (2) (1) (2) 357Qxx (1) Standard tank has round ends. or flat ends use suffix (2) xx indicates the of valves X003-27
TNK SYSTM SRIS 357 ORRIN xample: imension code for a 4 valves tank system: Tank diameter 8" Operator Remote Pipe 1 1/2" onnection Hose (see fig. 1: onnection Type) Number of valves 4 pcs Start and nd distance 170 mm Standard pitch 180 mm eviating pitch etween valve no. 3 and no. 4 is position (see fig. 1) 200 mm atalogue 357P04 24V/ imension code 170180200 SPR PRTS KITS spare parts kit no. ~/= 357Pxx 357Qxx 113826 ORRIN XMPL TNK SYSTM: 357P 04 (*) + 170 180 200 deviating pitch standard pitch start & end dist. tank end type no. of valves no. IMNSIONS (mm) RT. PLT HOS THR 80 Ø Ø H 80 40 ig.1 1/4" S ML (3x) lat ends (Suffix "") onnection Type tank diameter fig. min. start distance / / minimum pitch min. end distance Ø Ø H (round) (flat) (round) (flat) (round) (flat) 8" 1 170 118 160 160 170 118 218,1 1 1/2" 70 18 48,3 ( ) or standard tank (round ends) use no suffix, for flat ends use suffix MOUNTIN RKTS ig.2 - ontra bracket tank diameter fig. Ø H 8" 2 348 284 50 8 110 INSTLLTION H Ø13 tank diameter fig. Ø H 8" 3 210 348 200 284 50 8 110 Tank System can be mounted in any position. We can supply standard mounting brackets with each tank by specifying suffix M behind the (see figure 2 and 3) Installation / maintenance instructions and declaration of conformity are included with each tank system Spare part kits and coils are available X003-28 ig.3 - racket H Ø13 Ø13 X003-2014/R01