Diaphragm Valves. Clean Air Systems
|
|
|
- Sheryl Taylor
- 9 years ago
- Views:
Transcription
1 Diaphragm Valves Clean Air Systems
2 Technical Specification 3 Series Pulse Jet Valves FS3 Series T3 Series DD3 Series Description Superior performance, easy maintenance diaphragm valve available with threaded ports (T3), dresser nut ports (DD3) or flange and slide ports (FS3). Outlet at 90 to inlet. 3 Series valves are available as remote pilot valves and may be converted to integral pilot applications through the use of the screw in pilots of the MIP and 3DS series. Suitable for Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters. Construction Body: Aluminium (diecast) Seals: Nitrile or Viton (diaphragms reinforced) Spring: 304 SS Diaphragm Seat: PA-6 (standard), Viton coated mild steel Operation Recommended on time range: ms Recommended time between pulses: 1 minute or greater Maintenance Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually. Approvals Atex II 2D Mechanical CSA (C&US) C22.2 No UL Std No. 429 Installation For your safety do not pressurise system until all valves and pipes are fully secured. Do not attempt to remove a fitted valve while system is under pressure. 1. Prepare supply and blowtube pipes* to suit valve type and specification. Avoid installing valves underneath the tank. 2. Ensure tank and pipes are free from dirt, rust or other particulate. 3. Ensure supply air is clean and dry. 4. Mount valves to inlet pipes (or flanges, tighten bolts to 10Nm) and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. Ensure blowtube is fully inserted into the valve outlet. 5. Tanks and pipes must be independently restrained from FS and DD valves. 6. Connect RCAC pilot port to remote pilot valve, or install MIP/3DS screw in pilot valve. 7. Apply moderate pressure to system and check for installation leaks. 8. Fully pressurise system. 9. Test fire and listen for proper actuation and crisp pulse noise. Valve is not a structural component. Do not rely on valve to retain tanks or pipe. Refer to Camlock product specifications for installation details. *Pipes must be to Schedule 40 outside diameter Schedule 40 Size OD mm OD Inches ¾" " Weights Size Remote Pilot (RCAC) Size Remote Pilot (RCAC) Kg (lbs) Kg (lbs) 20T (1.21) 25T (1.43) 20ST (1.21) 25DD (2.32) 20DD (1.21) 25FS (2.08) 20FS (1.21) Maintenance Kits and Accessories Model Nitrile Viton Includes RCAC20T3, ST3, DD3, FS3 K2016 K2017 Diaphragm kits include main RCAC25T3, DD3, FS3, FH3 K2529 K2530 diaphragm, spring, and locking pin. 20DD3 Dresser nut seal kit K2018 K2019 Nut, seal, and seal retaining ring. 25DD3 Dresser nut seal kit K2533 K2534 Nut, seal, and seal retaining ring. 20FS3 Outlet seal replacement G G Outlet seal 25FS3 Outlet seal replacement G G Outlet seal 25FS3 Valve to baghouse wall seal G G Wall seal Camlock for 20 & 25FS3 and 6" round tank K Flange adaptor to mount FS Camlock for 20 & 25FS3 valves to round tanks. and 8" round tank K Eliminates welding. Refer to Camlock product specification. 2 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
3 Technical Specification - 3 Series Pulse Jet Valves Product Characteristics and Performance Model Port Size Number of Flow Pressure Range Temperature Range C (F) mm in diaphragms Kv Cv kpa(psi) Nitrile Seals Viton Seals 20T3 20 ¾" (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 20ST3 20 ¾" (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 20DD3 20 ¾" (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 20FS3 20 ¾" (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 25T3 25 1" (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 25DD3 25 1" (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) 25FS3 25 1" (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) Order Code RCAC 0 Diaphragm material 0=nitrile, 1=viton Thread type 0=NPT, 1=RC, 2=G Pilot size 0=1/ 8 1=1/4 Connection style Valve port size T3=Threaded, ST3=Short Threaded*, DD3=Dresser Nut, FS3=Flange in/slide out FH3=Flange inlet/hose outlet** 20, 25 mm *Available for 20 (3/4") size only. **Available for 25 (1") size only. Examples: RCAC25T3010 1" threaded port valve with 1/8" pilot, 1" RC port threads, nitrile seals. RCAC20FS3001 3/4" flange inlet slide seal outlet port valve with 1/8" NPT remote pilot port and viton seals. Dimensions (Dimensions in mm and [inches]) RCAC20T3 Copyright by Tyco International Ltd. Diaphragm Valves 06/08 3
4 Technical Specification - 3 Series Pulse Jet Valves RCAC20ST3 RCAC20DD3 4 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
5 Technical Specification - 3 Series Pulse Jet Valves RCAC20FS3 RCAC25T3 Copyright by Tyco International Ltd. Diaphragm Valves 06/08 5
6 Technical Specification - 3 Series Pulse Jet Valves RCAC25DD3 RCAC25FS3 6 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
7 Technical Specification T Series Pulse Jet Valves T Series Description High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90 to inlet. Suitable for Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters. Construction Body: Aluminium (diecast) Ferrule: 304 SS Armature: 430FR SS Seals: Nitrile or Viton (reinforced) Spring: 304 SS Screws: 302 SS Diaphragm Seat: PA-6 (standard), Viton coated mild steel or High Density PE Refer to Q Series Solenoid product data sheet for solenoid construction details. Operation Recommended on time range: ms Recommended time between pulses: 1 minute or greater Maintenance Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually. Approvals Integrally piloted valves meet the requirements of: Atex II 2D Mechanical CSA (C&US) C22.2 No UL Std No. 429 C-Tick - integral pilots EMC (89/336/CE) - integral pilots Installation 1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank. 2. Ensure tank and pipes are free from dirt, rust or other particulate. 3. Ensure supply air is clean and dry. 4, Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. 5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only). 6. Apply moderate pressure to system and check for installation leaks. 7. Fully pressurise system. 8. Test fire and listen for proper actuation and crisp pulse noise. Weights Size Integral Pilot Remote Pilot Size Integral Pilot Remote Pilot (CA) Kg (lbs) (RCA) Kg (lbs) (CA) Kg (lbs) (RCA) Kg (lbs) 10 NA 0.06 (0.14) (3.30) 1.28 (2.83) (1.31) 0.38 (0.83) (6.38) 2.68 (5.92) (1.61) 0.51 (1.13) (7.30) 3.09 (6.82) (2.28) 0.83 (1.83) (10.52) 4.56 (10.04) Maintenance Kits Model Nitrile Viton Low Temperature Includes -60 C (-76 F) Min. RCA10T K1001 K1002 NA CA/RCA20T K2000 K2007 NA CA/RCA25T K2501 K2503 K2504 CA/RCA32T* K NA CA/RCA35T K3500 K3501 K3502 CA/RCA40T* K NA CA/RCA45T K4502 K4503 K4522 CA/RCA50/62T K5004 K5000 NA CA/RCA76T K7600 K7601 NA Pilot repair kit K0380 K0384 NA o-ring, armature assembly, armature spring, ferrule Product Characteristics and Performance Nom. Port Size Number of Flow Size mm in diaphragms Kv Cv / / Pressure Range: 30(5) - 860(125) kpa(psi) Temperature Range: Nitrile Seals: -40 C (-40 F) to 82 C (179.6 F) Viton Seals: -29 C (-20.2 F) to 232 C (449.6 F) Diaphragm kits include main and secondary diaphragms (where required) and all springs. *These kits are for discontinued valves. Copyright by Tyco International Ltd. Diaphragm Valves 06/08 7
8 Technical Specification - T Series Pulse Jet Valves Order Code T - Solenoid type Diaphragm material Solenoid order code, drop the K- Refer to Q Series Solenoid product specification 0=nitrile, 1=viton Thread type 0=NPT, 1=RC, 2=G Pilot size 0=1/8, 1=1/4 Valve size Pilot type 20, 25, 35*, 45*, 50, 62, 76 mm RCA=remotely piloted, CA=integral pilot *Note that the 35 & 45 share the same port sizes. Order Code RCA10T Series RCA10-6T/645 (1/4 NPT) RCA10-6T/669 (1/4 BSPT) Examples: CA50T " threaded port valve with 1/8" pilot, 2" RC port threads, nitrile seals and 200/240VAC integral pilot with DIN socket terminals. RCA25T001 1" threaded port valve with 1/8" NPT remote pilot port, 1" NPT port threads and viton seals. Dimensions (Dimensions in mm and [inches]) RCA10T 8 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
9 Technical Specification - T Series Pulse Jet Valves CA/RCA20T CA/RCA25T Copyright by Tyco International Ltd. Diaphragm Valves 06/08 9
10 Technical Specification - T Series Pulse Jet Valves CA/RCA35T CA/RCA45T 10 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
11 Technical Specification - T Series Pulse Jet Valves CA/RCA50T CA/RCA62T Copyright by Tyco International Ltd. Diaphragm Valves 06/08 11
12 Technical Specification - T Series Pulse Jet Valves CA/RCA76T 12 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
13 Technical Specification DD Series Pulse Jet Valves DD Series Description High performance diaphragm valve with dresser nut ports. Available with integral pilot or as remotely piloted valve. Outlet at 90 to inlet. Suitable for Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters. Construction Body and Dresser Nuts: Aluminium (diecast) Ferrule: 304 SS Armature: 430FR SS Seals: Nitrile or Viton (reinforced) Spring: 304 SS Screws: 302 SS Dresser Nut Seals: Nitrile or Viton Diaphragm Seat: PA-6 (standard), Viton coated mild steel or High Density PE Refer to Q Series Solenoid product data sheet for solenoid construction details. Operation Recommended on time range: ms Recommended time between pulses: 1 minute or greater Maintenance Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually. Approvals Integrally piloted valves meet the requirements of: Atex II 2D Mechanical CSA (C&US), C22.2 No UL Std No. 429 C-Tick - integral pilots EMC (89/336/CE) - integral pilots Installation For your safety do not pressurise system until all valves and pipes are fully secured. Do not attempt to remove a fitted valve while system is under pressure. 1. Prepare supply and blowtube pipes* to suit valve specification. Avoid installing valves underneath the tank. 2. Ensure tank and pipes are free from dirt, rust or other particulate. 3. Ensure supply air is clean and dry. 4. Mount valve to inlet pipes and blowtube to valve, tighten dresser nut. 5. Tanks and pipes must be independently restrained from valve. 6. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only). 7. Apply moderate pressure to system and check for installation leaks. 8. Fully pressurise system. 9. Test fire and listen for proper actuation and crisp pulse noise. Valve is not a structural component. Do not rely on valve to retain tanks or pipe. *Pipes must be to Schedule 40 outside diameter Schedule 40 Size OD mm OD Inches ¾ Weights Size Integral Pilot (CA) Remote Pilot (RCA) Kg (lbs) Kg (lbs) (1.80) 0.61 (1.34) (2.67) 0.99 (2.18) (5.03) 2.11 (4.65) Maintenance Kits Model Nitrile Viton Low Temperature Includes -60 C (-76 F) Min. Diaphragm Kit CA/RCA20DD K2000 K2007 NA Diaphragm kits include CA/RCA25DD K2501 K2503 K2504 main and secondary CA/RCA45DD K4502 K4503 K4522 diaphragms (where required) and all springs. Dresser Seal Kit CA/RCA20DD K2008 K2009 NA 1 dresser seal, 1 dresser nut, 1 seal retainer CA/RCA25DD K2508 K2507 NA 1 dresser seal, 1 dresser nut, 1 seal retainer CA/RCA45DD K4510 K4511 NA 1 dresser seal, 1 dresser nut, 1 seal retainer Pilot repair kit (suits all CA valves) K0380 K0384 NA o-ring, armature assembly, armature spring, ferrule Copyright by Tyco International Ltd. Diaphragm Valves 06/08 13
14 Technical Specification - DD Series Pulse Jet Valves Product Characteristics and Performance Nom. Port Size Number of Flow Pressure Range Temperature Range C (F) Size mm in diaphragms Kv Cv kpa(psi) Nitrile Seals Viton Seals ¾ (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) Order Code DD - Solenoid type Diaphragm material Pilot thread type Solenoid order code, drop the K- Refer to Q Series Solenoid product specification 0=nitrile, 1=viton 0=NPT, 1=RC Pilot size 0=1/8, 1=1/4 Valve size Pilot type 20, 25, 45 mm RCA=remotely piloted, CA=integral pilot Examples: CA45DD " dresser nut port valve with 1/8" RC pilot, nitrile seals and 220/240VAC integral pilot with DIN socket terminals. RCA25DD001 1" dresser nut port valve with 1/8" NPT remote pilot port and viton seals. Dimensions (Dimensions in mm and [inches]) CA/RCA20DD 14 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
15 Technical Specification - DD Series Pulse Jet Valves CA/RCA25DD CA/RCA45DD Copyright by Tyco International Ltd. Diaphragm Valves 06/08 15
16 Technical Specification FS Series Pulse Jet Valves FS Series Description Very high performance diaphragm valve with flanged inlet port and slide seal outlet port for easy valve installation and removal. Available with integral pilot or as remotely piloted valve. Outlet at 90 to inlet. Suitable for Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters. Construction Body: Diecast aluminium or 316 stainless steel Ferrule: 304 SS Armature: 430FR SS Seals: Nitrile or Viton (reinforced) Spring: 304 SS Screws: 302 SS Outlet Slide Seal: EPDM or Viton Diaphragm Seat: PA-6 (standard), Viton coated mild steel Refer to Q Series Solenoid product data sheet for solenoid construction details. Operation Recommended on time range: ms Recommended time between pulses: 1 minute or greater Maintenance Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually. Approvals Integrally piloted valves meet the requirements of: Atex II 2D Mechanical CSA (C&US) C22.2 No UL Std No. 429 C-Tick - integral pilots EMC (89/336/CE) - integral pilots Installation 1. Prepare inlet flange and blowtube pipes* to suit valve specification. Avoid installing valves underneath the tank. 2. Ensure tank and pipes are free from dirt, rust or other particulate. 3. Ensure supply air is clean and dry. 4. Mount valves to inlet flange and blowtube to valves with all seals in place. Tighten flange bolts to 10Nm (7.4 ft-lbs) Ensure blowtube is pushed all the way into the valve outlet. 5. Tanks and pipes must be independently restrained from valve. 6. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only). 7. Apply moderate pressure to system and check for installation leaks. 8. Fully pressurise system. 9. Test fire and listen for proper actuation and crisp pulse noise. Valve is not a structural component. Do not rely on valve to retain tanks or pipe. Refer to Camlock product specification for installation details. *Pipes must be to Schedule 40 outside diameter Schedule 40 Size OD mm OD Inches Weights Size Integral Pilot (CA) Remote Pilot (RCA) Kg (lbs) Kg (lbs) (2.31) (1.82) (4.03) (3.55) Maintenance Kits Model Nitrile Viton Includes CAC/RCAC25FS Diaphragm kit K2501 K2503 The main diaphragm, CA/RCA45FS Diaphragm kit K4502 K4503 secondary diaphragm (45FS only) and spring(s). CAC45FS to CA45FS Integral pilot K4532(NPT) K4537(NPT) The complete CA integrally cover conversion kit K4538(BSP) K4539(BSP) piloted valve cover assembly. Does not include main diaphragm, main diaphragm spring, cover bolts or main bleed pin. RCAC45FS to RCA45FS Remote K4533(BSP) K4534(BSP) The complete RCA remotely pilot cover conversion kit K4535(NPT) K4536(NPT) piloted valve cover assembly with main diaphragm and spring. Does not include cover bolts or main bleed pin. Integral pilot repair kit (CA45FS K0380 K0384 O-ring armature assembly, and CAC25FS only) armature spring, ferrule. Integral pilot repair kit K0390 N/A O-ring armature assembly, CAC45FS only) armature spring, ferrule. 25FS Outlet seal G G Outlet seal 45FS Outlet seal G G Outlet seal 16 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
17 Technical Specification - FS -??? Series Jet Valves Pulse Jet Valves Product Characteristics and Performance Nom. Port Size Number of Flow Pressure Range Temperature Range C (F) Size mm in diaphragms Kv Cv kpa(psi) Nitrile Seals Viton Seals (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) Order Code FS 0 - Solenoid type Diaphragm Pilot thread type Valve size Pilot type Solenoid order code, drop the K- Refer to Q Series Solenoid product specification 0=nitrile, 1=viton 0=NPT, 1=RC, 9=NPT & stainless steel valve body 25, 45 mm 25 RCAC=remotely piloted, CAC= integral pilot 45 RCA=remotely piloted, CA=integral pilot Examples: CA45FS " FS valve with 1/8" RC pilot, nitrile seals and 220/240VAC integral pilot with DIN socket terminals. RCAC25FS091 1" FS valve with 1/8" NPT remote pilot port, stainless steel body and valve cover, and viton seals. Dimensions (Dimensions in mm and [inches]) CAC/RCAC25FS Copyright by Tyco International Ltd. Diaphragm Valves 06/08 17
18 Technical Specification - FS Series Pulse Jet Valves CA/RCA45FS 18 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
19 Technical Specification MM Series Pulse Jet Valves MM Series Description Very high performance diaphragm valve designed to be mounted directly into the compressed air manifold. 1" and 1.5" models are supplied with outlet pipes to length specified, 3" and 3.5 models are supplied without outlet pipes. Suitable for Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters. Construction Body and Dresser Nuts: Diecast Aluminium Ferrule: 304 SS Armature: 430FR SS Diaphragm and Seals: Nitrile or Viton (reinforced) Spring: 304 SS Screws: 302 SS Outlet Pipe: Schedule 40 wrought steel zinc passivated Diaphragm Seat: PA-6 (25 & 40MM standard), Nitrile coated mild steel (76MM standard), or Viton coated mild steel (all sizes) Refer to Q Series Solenoid product data sheet for solenoid construction details. Operation Recommended on time range: ms Recommended time between pulses: 1 minute or greater Maintenance Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually. Installation 1. MM valves are installed through the tank, refer to the appropriate template listed above. 2. To avoid any potential operational problems it is preferable that the valves are not mounted underneath the tank where condensation may collect. All o-rings should be coated with a silicone based lubricant or similar. 3. Dresser nut seals where used are a pressure seal only, not a structural component. Do not rely on dresser seals to retain either the tanks or blowtubes. Tanks and blowtubes must be independently restrained. 4. Tighten dresser nuts to 20Nm (15 ftlbs) max. 5. Tighten pipe outlets to 20 Nm (15 ftlbs). 6. Connect to Goyen pilot valve, if remotely actuated. 7. Ensure compressed air supply is dry and free from oil and dirt. 8. Check all cleaning system components are secure before applying pressure. 9. Apply moderate pressure and check for leaks. 10.Fully pressurise system. 11.Test fire and listen for proper actuation and crisp pulse noises. Weights Size Integral Pilot (CA) Remote Pilot (RCA) Kg (lbs) Kg (lbs) (1.59) (1.10) (2.47) (1.98) (8.60) (8.11) (8.60) (8.11) Maintenance Kits and Accessories Model Nitrile Viton Includes CA/RCA25MM Diaphragm kit K2501 K2503 Diaphragm kits include main CA/RCA40MM Diaphragm kit K4000 K4007 and secondary (where CA/RCA76MM Diaphragm kit K7600 K7601 required) diaphragms and CA/RCA102MM Diaphragm kit K10200 K10201 all diaphragm springs. Pilot repair kit (all models) K0380 K0384 o-ring, armature assembly, armature spring, ferrule CA/RCA25MM*P Installation template Drawing Installation templates are CA/RCA25MM*D Installation template Drawing available free of charge. CA/RCA40MM*P Installation template Drawing CA/RCA40MM*D Installation template Drawing CA/RCA76MM Installation template Drawing Suitable for 102MM hose and CA/RCA102MM Installation template Drawing and Approvals Integrally piloted valves meet the requirements of: Atex II 2D Mechanical CSA (C&US) C22.2 No UL Std No. 429 C-Tick - integral pilots EMC (89/336/CE) - integral pilots Copyright by Tyco International Ltd. Diaphragm Valves 06/08 19
20 Technical Specification - MM Series Pulse Jet Valves Product Characteristics and Performance Nom. Port Size Number of Flow Pressure Range Temperature Range C (F) Size mm in diaphragms Kv Cv kpa(psi) Nitrile Seals Viton Seals (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) (5) - 860(125) -40(-40) to 82(179.6) -29(-20.2) to 232(449.6) Order Code 1 and 1.5 Models MM - Solenoid type Solenoid order code, drop the K- Refer to Q Series Solenoid product specification Diaphragm 0=nitrile, 1=viton Pilot thread type 0=NPT, 1=RC Thread & bleed size 0=1/8, bleed diameter 1=1/4, bleed diameter 2=1/8, bleed diameter 3=1/4, bleed diameter Tank width 4*, 5*, 6, 8! Inches *25MM only,! 40MM only (omit if ordering valve only) Outlet pipe type P=Pipe flange, D=Dresser nut (flat faced tanks only) (omit if ordering valve only) Tank shape F=Flat faces, R=Round (omit if ordering valve only) Valve size 25, 40 mm Pilot type RCA=remotely piloted, CA=integral pilot 3 and 3.5 Models MM - Solenoid type Diaphragm Thread type Solenoid order code, drop the K- Refer to Q Series Solenoid product specification 0=nitrile, 1=viton 0=NPT, 1=RC Remote pilot size 0=1/8, 1=1/4 specify 0 for CA models Valve size Pilot type 76,102 mm RCA=remotely piloted, CA=integral pilot Examples: CA40MMFD " MM valve to suit a flat faced tank with a dresser nut outlet, 1/8" NPT exhaust port, Ø0.062" bleed, nitrile seals and 220/240VAC integral pilot with DIN socket terminals. RCA25MMRP5001 1" MM valve to suit a Ø 5" round tank with pipe flange outlet, 1/8" NPT remote pilot port, Ø0.062" bleed and viton seals. RCA25MM001 1" MM valve only, 1/8" NPT remote pilot, Ø0.062" bleed and viton seals. 20 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
21 Technical Specification - MM Series Pulse Jet Valves Dimensions (Dimensions in mm and [inches]) CA/RCA25MM Note: Pipe outlet not shown CA/RCA40MM Note: Pipe outlet not shown Copyright by Tyco International Ltd. Diaphragm Valves 06/08 21
22 Technical Specification - MM Series Pulse Jet Valves CA/RCA76MM Note: Suggested pipe size is 3 NB Schedule 40 pipe (OD=89.0mm, 3.5 ) 22 Copyright by Tyco International Ltd. Diaphragm Valves 06/08
23 Technical Specification - MM Series Pulse Jet Valves CA/RCA102MM Note: Suggested pipe size is 3.5 NB Schedule 30 pipe (OD=101.6mm, 4 ) Copyright by Tyco International Ltd. Diaphragm Valves 06/08 23
24 Australia Head Office Goyen Controls Co Pty Ltd 268 Milperra Road Milperra, NSW 2214 Telephone: Facsimile: Asia Goyen Controls Co Pty Ltd Shanghai Representative Office 1209 Greenland Business Centre 1258 Yu Yuan Road Shanghai PC CHINA Telephone: Facsimile: Europe Goyen Controls Co UK Ltd Unit 3B Beechwood Chineham Business Park Basingstoke, Hampshire, RG24 8WA UNITED KINGDOM Telephone: Facsimile: Queensland Telephone: Facsimile: Victoria Telephone: Facsimile: Goyen Controls Co Pty Ltd 73-M Jalan Mega Mendung Kompleks Bandar OUG Kuala Lumpur MALAYSIA Telephone: Facsimile: Office: Singapore Tel/Facsimile: Tyco Umwelttechnik GmbH Im Petersfeld 6 D Altendiez GERMANY Telephone: /1002 Facsimile: South Australia Telephone: Facsimile: Western Australia Telephone: Facsimile: USA Goyen Valve Corporation 1195 Airport Road Lakewood New Jersey USA Telephone: Facsimile: Mecair S.r.l. Via per Cinisello Nova Milanese Milano, ITALY Telephone: Facsimile: DiaValves Rev8 6/08
Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve
High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side
Proportional reducer D386 ATEX Classification according Article 3.3 of European Directive n 97/23/CE from 29/05/1997 Classification according group II, category 2 and temperature class T4 of ATEX Directive
Shut-off & Lockout Valves 1/4" to 1-1/2" port size
Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
Stainless Steel Valves For the Sanitary Industries
www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
SOLENOID VALVES AND PNEUMATIC VALVES
2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the
SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research
2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
Baumann 24003 3 Way Bronze or Stainless Steel Control Valve
Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
Baumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
MVX-Series Diesel Engine Air Shut Down Valves
MVX-Series Diesel Engine Air Shut Down Valves (Cable operated closure/integral reset lever types) Selection, Application and Maintenance SPECIAL VALVE MVX-304 This is a special version of valve type MVX-303
Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.
Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical
Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40
Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane
*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...
Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage
Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
POWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2
POWR PULS VLVS pilot threaded or Quick Mount 3/4 to 1 1/2 N 2/2 Series 353 TURS The piston cartridge pulse valves are especially designed for dust collector service applications, combining high flow, long
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
Vacuum Gate Valve DN 100 and DN 150
Vacuum Gate Valve DN 100 and DN 150 WER Dok.E.02.050_02.051 1. Introduction/Safety Instructions 2. Description 3. Technical Data 4. Installation 5. Operation 6. Maintenance Instructions 7. Spare Parts
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
Check Valves & Actuated Valves
heck Valves & ctuated Valves & U Series Piston non-return valves rated 6,000 psi & 10,000 psi X Series Piston non-return valves rated 20,000 psi Pneumatic ctuators Pneumatically actuated valves Electric
% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed
TY-FLO Needle Valves
Design/Features Hard (Vee) or Delrin Soft Seat/Tip Orifice sizes from.17 to.438 in. Flow Coefficients (C V ) from.37 to.7 Straight or angle flow patterns Optional panel mount Handle options available Non-wetted
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
M A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Ends : Min Temperature : Max Temperature : DN 32/40 to DN 1000 Between flanges GN10/16, ASA150 up to DN600-10 C + 110 C ( 130 C temporarily ) Max Pressure : 16 Bars up to DN300 Specifications :
1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
TECHNICAL DATA. Dry 122a. November 12, 2013
Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model
Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage
Safety for Hydraulics Leak free check valve, pilot operated, series Cartridge type, two stage prevents a load from falling if a burst occurs in feed pipe hardened seat and poppet prevents creep of hydraulically
Direct steam injection humidifiers
Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature
Standard Bills of Materials Commonly Ordered Models Only
Standard Bills of Materials Commonly Ordered Models Only Meters Always check www.lcmeter.com for the most current BOM. This document is for reference only. Always use Bill of Material shipped with meter
Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
RUBBER SLEEVE KNIFE GATE VALVE
RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve
MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)
MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types) Selection, pplication and Maintenance Valve Numbers MVX-301 MVX-302 MVX-303 MVX-501 MVX-502 MVX-503 MVX-801
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
FRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
Round Housing with Side Ports
Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End
Fisher 2625, 2625SST, and 2625NS Volume Boosters
Instruction Manual 2625, 2625SST, and 2625NS Volume Booster Fisher 2625, 2625SST, and 2625NS Volume Boosters Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Educational
Check Valves Valve locator
Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()
ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP
ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP ARI-DP30 Pneumatic actuator Page 2 ARI-DP32 ARI-DP33 Pneumatic actuator DP-Actuator Extended stem
AUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
STC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
OCTOPUS SELECTION & INSTALLATION GUIDE
OCTOPUS SELECTION & INSTALLATION GUIDE 38mm BORE LINEAR ACTUATOR STYLES LAM & LAR A. GENERAL DESCRIPTION: The Octopus hydraulic linear actuator is a simple, efficient and reliable way of driving the rudder
Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions
4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation
FLANGED END BALL VALVE
Specification: FLANGED END BALL VALVE - Chem Oil s two-piece ball valve has been designed to handle extreme service applications with unsurpassed reliability. Valve body machined from solid wrought material
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return
Pneumatic Actuator Double Acting or Spring Return Since the mid-sixties the Norbro name has been recognised as the leading quarter turn actuator for industry. As proof of this, Norbro pneumatic actuators
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
Pressure switches for gas and air Pressure sensors
Pressure switches for gas and air Pressure sensors line overview.0 Printed in Germany Rösler Druck Edition 08.00 Nr. 28 373 Page Karl Dungs GmbH & Co. - The pressure switch specialists For decades we have
Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!
Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm
Type K current limiting fuse canister Technical information and installation guide
Transformer components Type K current limiting fuse canister Technical information and installation guide The Type K current limiting fuse canister provides an air-insulated receptacle for general-purpose
Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM
SLAM-SHUT VALVE Type OSE Process Management TM DESCRIPTION The purpose of the OSE slam shut valve is to totally and rapidly cut off gas flow when the outlet pressure exceeds or drops below the setting.
Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value
Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be
Block and Bleed Gauge Valves M25 and M251
Product Overview The M25 and M251 are two-valve single outlet gauge valves that combine isolating, calibrating, and venting facilities in a single compact unit. These valves enable gauges, pressure transmitters,
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.
D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these
HOSE, TUBE, AND PIPE CLAMPS
hose, tube & clamp B/W pages 24/6/08 9:28 AM Page 2 HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions
Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
Fisher 377 Trip Valve
377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls
167D Series Switching Valves
June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
REGULATORS D& HD Series
Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2002 Watson McDaniel Company Ductile Iron body - HD Series Full port strainer & blowdown valve on pilot
Delivery Programme 2013
Delivery Programme 2013 Catalysts Exhaust-Systems Diesel Particulate Filters Universal Competition Exhaust Parts www.hjs-motorsport.com Motorsport Catalysts Catalytic Converter Technology: HJS offers a
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
QLM and QLD Series Three-port Control Valves
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas
BROEN UNIFLEX Fittings FOR BURNIN ASES BROEN UniFlex TM Fittings for burning gases BROEN UniFlex TM Fittings for burning gases LAB Table of Contents Content Page Table of Content 2 Product Overview 3 BROEN