DIRECTIONAL CONTROL VALVES



Similar documents
Solenoid Operated Directional Valves

Solenoid Operated Directional Valves

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

Unit 24: Applications of Pneumatics and Hydraulics

Directional Control Valves

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

3/2- and 2/2-way cartridge valve type BVE

2/2 and 3/2 Way Size 6 Seat Valves

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Assisted lift operated 2/2-way solenoid valves Type EV250B

Control block EDD Modular Directional Valve

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

STC 3S A Series Solenoid Valves

Electro-pneumatic control valves

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

RA / Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

Circuit Breakers. NRC Series. NRC Series

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

3 Port Solenoid Valve

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

TS93 EMR T/PT/TDE. Surface applied door closer

Single sub-base valve

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

3 Port Solenoid Valve

SOLENOID VALVES 3-4 WAY

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Valves. Sub-Base Mounted Valves to ISO 5599/2

GROENEVELD AUTOMATIC GREASING SYSTEMS

Directional Controls. Solenoid Operated Directional Valve DG4V-3S, EN 490 For Mobile Equipment

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Cable Plug acc. to DIN EN , Form A

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

FAQ s on Siemens Magmeters

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

2.12. page Products for Explosion hazardous Environment

Pressure Relief Valves for Pipe Mounting

PVH131/141 Variable Displacement Piston Pump - 11 Design

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Electro-Pneumatic Bus Door Control Mechanism

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Industrial Hydraulic Remote Controlled Monitor

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

4 Posiflow Proportional Solenoid Valves

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Model Number Structure

MDT5N25 & MTD5N40 SERVICE PARTS

Series PVP Variable Volume Piston Pumps

3/2 Solenoid Cartridge Valve, Size 6

Model Number Structure

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

3/2-way Solenoid Valve, direct-acting, NC or NO

RY2 miniature industrial relays

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Line-Mounted Valves L Series

System 8. ü ( System 8

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Electro-hydraulic pressure switches type DG

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

Electronically Controlled Air Suspension (ECAS) for Trucks

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

TELEPHONE LINE ANALYZER KIT

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

Load-sensing control block in mono and sandwich plate design

Actuators and Sensors. Products

Pressure Relief. Pressure Relief Valves. Vickers

TorqPlus TM Electric Valve Actuators and Controls

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Modular I/O System Analog and Digital Interface Modules

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Chapter 6: Check Valves

Directional seated valves type VP 1

VOIP-500 Series Phone Quick Installation Guide

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

GLOLAB Two Wire Stepper Motor Positioner

Emergency lighting units EM powerled

DCS Input/Output Relay Card Series

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Transcription:

Series 35 High Flow High Pressure Directional Valves D05SD DIN Type D05S Electrical Box Type D03SD DIN Type D03S Electrical Box Type D03SL Lead Wire Type (D05SL Lead Wire Type Also available) FEATURES High Flow/ High Pressure: Up to 25 gpm (D03) and 40 gpm (D05)/ 5,000 psi working pressure*. Oil Immersed, Quiet Solenoid Design: Moving core immersed in hydraulic oil provides quiet operation. High Tank Port Pressure: Up to 3,000 psi tank port back pressure (Check each spool type for max. allowable) Twin Tank Line Design: Upper and lower tank line channels (Double Loop) greatly reduces pressure drop. Wiring: Electrical box with indicator lights and terminal strip connection standard. DIN connector provided standard on DIN style coils. (Connectors may optionally be supplied with lights.) Hydraulic/ Electric Shockless: Valve coils available electric shockless (rectified)- reducing voltages spikes, extending relay contact life, and providing even quieter operation. Spool shifting time is increased up to four times by metering the oil in the core tube. Option F (Electrical Box version only) Maintenance: Indicator lamps to diagnose connection; Plug-in coils provide easy changing without disturbing wiring. High Reliability: Valve designed to last 30 million spool shifts under proper use. Bolt Kit included with valve standard *Some spools rated less- check max. pressures and flows page 4.

Internal Structure NFPA D03 D03 with Double Loop High Flow Design Electrical box with indicator lights and terminal strip connection standard. Electrical boxes shown with optional rectifiers. (Code X) NFPA D05 D05 with Double Loop High Flow Design 5 Channel 6 Tooth Design

Specifications

Specifications Symbols

Common 115 VAC Models D03 D05 Symbol Common Configurations Electrical Box Din Coil D03S-1A-115A-35 D05S-1A-115A-35 A D03S-1 - D03S-5 - D03SD-1 - D03SD-5 - D03S-1AY-115A-35 D05S-1AY-115A-35 AY D03S-2B-115A-35 D05S-2B-115A-35 B D03S-2 - D03S-3A- D03SD-2 - D03SD-3A- D03S-2C-115A-35 D05S-2C-115A-35 C D03S-2F-115A-35 D05S-2F-115A-35 F D05S-1 - D05S-5 - D05SD-1 - D05SD-5 - D03S-2H-115A-35 D05S-2H-115A-35 H D03S-2K-115A-35 D05S-2K-115A-35 K D05S-2 - D05S-3A- D05SD-2 - D05SD-3A- D03S-2T-115A-35 D05S-2T-115A-35 T D03S-3A-115A-35 D05S-3A-115A-35 A D0 -SP- -DC Single Spade Connector Now Available ORDERING INFORMATION SOLENOID DIRECTIONAL VALVE PART NUMBERING SYSTEM: D03 S-2 B-115 A-35 Example: D03 Valve, double solenoid, 3 position, spring centered, all ports blocked in center, 115 volt- ac coils Size D03 D05 Code S SD SF Actuator Solenoid Soln. w/ Din Coil Hydraulic Shockless Specify: (special order) SL for lead wire SP for single spade plug Code 1 2 3 5 Configuration Single solenoid 2 position spring offset Double solenoid 3 position spring centered Double solenoid 2 position no center, detented Single solenoid 2 position spring centered Code A AY B C F H K T Spool Function P to A, B to T P to A, B to T All Ports Blocked A & B Blocked P to T A & B to T P Blocked All Ports Open A to T P & B Blocked P to A & B, T Blocked A spool is closed in transition AY spool is open in transition Voltage 12 24 115 230 Current/ Connector A AC D DC Notes: Lights included standard on electrical box style. Code R (reversed) added behind spool code for flow supplied opposite of standard. Codes 1AR & 1AYR: spool & coil reversed Codes 2 R & 3AR: electrical box reversed Code 5 R: coil provided on reversed b side

Electrical Information D03 Solenoid Coil Specifications Solenoid Voltage Coil Model D03S (Elect. Box) Coil Model D03SD (DIN) Applied Voltage Frequency (Hz) Starting Current (A) Holding Current (A) Holding Power (W) Permissible Voltage Range (V) Insulation Resistance (MΩ) 115V-AC 2BH-C1/C3 2AH-C1/C3 AC110 AC120 50 60 60 2.2 2.0 2.2 0.54 0.41 0.47 25 22 28 80-120 230V-AC 2BH-C2/C4 2AH-C2/C4 AC220 AC240 50 60 60 1.1 1.0 1.0 0.25 0.19 0.23 25 22 28 180-240 115V-RAC (rectified) 2BF-R1/R3 2AF-R1/R3 AC110 AC120 50 / 60 0.31 0.32 30 32 80-130 100 or above (500V) 230V-RAC (rectified) 2BF-R2/R4 2AF-R2/R4 AC220 AC240 50 / 60 0.15 0.16 30 32 180-250 12V-DC 2BF-D1 2AF-D1 DC12 2.5 30 10.8-13.2 24V-DC 2BF-D2 2AF-D2 DC24 1.25 30 21.6-26.4 D05 Solenoid Coil Specifications Solenoid Voltage Coil Model D05S (Elect. Box) Coil Model D05SD (DIN) Applied Voltage Frequency (Hz) Starting Current (A) Holding Current (A) Holding Power (W) Permissible Voltage Range (V) Insulation Resistance (MΩ) 115V-AC 3BH-C1/C3 3AH-C1/C3 AC110 AC120 50 60 60 5.5 4.6 5.0 1.1 0.86 1.0 36 34 42 80-120 230V-AC 3BH-C2/C4 3AH-C2/C4 AC220 AC240 50 60 60 2.7 2.3 2.5 0.52 0.42 0.48 36 34 32 180-240 115V-RAC (rectified) 3EB-R1/R3 3EA-R1/R3 AC110 AC120 50 / 60 0.46 0.49 31 34 80-130 100 or above (500V) 230V-RAC (rectified) 3EB-R2/R4 3EA-R2/R4 AC220 AC240 50 / 60 0.22 0.24 30 33 180-250 12V-DC 3EB-D1 3EA-D1 DC12 3.0 31 10.8-13.2 24V-DC 3EB-D2 3EA-D2 DC24 1.5 36 21.6-26.4 Other Configurations Examples of Code R - Reversed (symbols shown in simplified form) D03SD-2B (standard) D03SD-2BR (no change to DIN coil valve, electrical box flipped for opposite coil markings) D03SD-1A (standard) D03SD-1AR (coil supplied reversed from normal position & spool reversed) D03SD-5B (standard) D03SD-5BR (right or b coil side of valve provided) (symbol shown blocked during valve transition only) Notes: DIN Coils manufactured to accept standard 3 pin DIN 43 650 and ISO 4400 connectors. AC Coils are rated for both 50/60Hz (rewiring not required) DC coils are not polarity sensitive Rectifier is supplied: in the electrical box- D03S, D05S in the coil (internal)- D03SD, D05SD Hydraulic shockless AC valves are always supplied with rectifier. Hydraulic shockless valves will not operate as shockless until the tank line has become filled with oil- occurs automatically after the first few cycles. Mounting valve below the reservoir oil level or using check valve ensures that the tank line remains filled. Do not supply electrical power to the AC coils unless the coil is mounted on the valve. Do not exceed voltage specifications shown above. Electrical power should be maintained on detented valves (spool code 3A). Detent only maintains start-up position of the valve.

Pressure Drop Curves Earth Terminal Solenoid b Terminal Earth Terminal Solenoid b Terminal Indicating Light Solenoid a Terminal Indicating Light Common Jumper Indicating Light Common Terminal Terminal supplied on a (right side) for code R reversed coil valve Common Terminal Earth Terminal

Electrical Box Type D03S D03SF Dimensional Data NFPA SIZE: DO3 1.48 0.22 Dia. 4.04 4.04 Mounting: (4) 10-24 SHCS x 1-3/4 Torque 40-45 in-lbs 2.60 4.04 1.65 8.07 (2) 1/2 NPT 5.69 Indicator Light 2.80 1.00 1.87 3.48 1.48 0.30 Dia. Indicator Light 0.22 Dia. 1.81 Push pin for manual operation 4.52 1.66 9.04 DIN Type D03SD 1.88 1.48 Mounting: (4) 10-24 SHCS x 1-3/4 Torque 40-45 in-lbs 4.04 5.57 2.60 1.54 0.22 Dia. 4.04 4.04 8.07 1.88 3.13 1.00 1.87 3.58 0.30 Dia. 1.48 0.22 Dia. 1.81 Push pin for manual operation 4.52 9.04 1.54 Lead Wire Type D03SL 1.48 Mounting: (4) 10-24 SHCS x 1-3/4 Torque 40-45 in-lbs 0.22 Dia. 4.52 1.54 9.04

Electrical Box Type D05S D05SF Indicator Light Dimensional Data 0.43 Dia. NFPA SIZE: DO5 Mounting: (4) 1/4-20 SHCS x 1-1/2 Torque 105-110 in-lbs Indicator Light 4.71 4.71 9.43 (2) 1/2 NPT 2.68 4.29 3.60 1.42 1.02 1.02 2.76 0.27 Dia. 0.27 Dia. Push pin for manual operation 3.66 5.24 2.28 4.71 2.28 10.48 7.00 DIN Type D05SD 0.43 Dia. Mounting: (4) 1/4-20 SHCS x 1-1/2 Torque 105-110 in-lbs 4.71 4.71 9.43 2.52 2.68 4.53 4.07 1.42 1.02 1.02 2.76 0.27 Dia. 0.27 Dia. Push pin for manual operation 3.66 5.24 2.28 4.71 2.28 10.48 7.00 Lead Wire Type D05SL Mounting: (4) 1/4-20 SHCS x 1-1/2 Torque 105-110 in-lbs 5.62 2.28 11.24 1.02 0.27 Dia.

NFPA SIZE: DO3 Parts Breakdown D03S/ D03SD/ D03SL Series 35 1) Solenoid Nut 2) O-Ring 3) Coil For Elect. Box Type) 4) Armature (Core Tube) 5) O-Ring 6) Push Pin 7) Spring 8) Retainer Parts Breakdown D03S/ D03SD/ D03SL Series 35 9) Washer 10) Spool (3 position) 11) O-Ring 12) Body 13) O-Ring 14) Concave Pin 15) Spool (2 position detent) 16) O-Ring 17) Hex Plug 18) Spring 19) Spool (2 pos. single coil) 20) Body 21) Retainer 22) Electrical Box 23) Screw 24) Acrylic Cover 25) Nameplate (Elect. Box) 26) Screw 27) Nameplate (Non-Box Type) 28) Screw 29) Coil (For DIN Type) 30) Connector 31) Screw 32) Coil (For Lead Wire Type)

NFPA SIZE: DO5 Parts Breakdown D05S/ D05SD/ D05SL Series 35 1) Solenoid Nut 2) O-Ring 3) Coil For Elect. Box Type) 4) O-Ring 5) Armature (Core Tube) 6) O-Ring 7) Push Pin 8) Spring Parts Breakdown D05S/ D05SD/ D05SL Series 35 9) Retainer 10) Spool (3 position) 11) Body 12) O-Ring 13) Concave Pin 14) Spool (2 position detent) 15) O-Ring 16) Hex Plug 17) Spool (2 pos. single coil) 25) Screw 18) Retainer 26) Coil (For DIN Type) 19) Joint Box 27) Connector 20) Joint Box Screw 28) Screw 21) Acrylic Cover 29) Coil (For Lead Wire Type) 22) Nameplate 23) Screw 24) Nameplate (Non-Box Type)