TECHNICAL. Add Peripherals without Changing Your Phone System C-1000A. Door Entry Controller



Similar documents
Add Door Phones to Your Phone System

K-2000-DVA See at a Glance when Lines are Multi-Input Ringing Voice. Telecommunication Peripheral Products. Technical Practice

INSTALLATION INSTRUCTIONS

TECHNICAL C-2000B. Add Entry Phones and Doorstrike Control to an Existing Line Or Securely Operate Multiple Doorstrikes

TECHNICAL. Add Paging and Multiple Line Loud Ringing to Any Phone System. PA-2A Paging Amplifier Loud Ringer

Telecom & Security Solutions for the 21st Century! Apartment and Office Entry Systems. Doorboxes and Doorbox Controller. Accessible Entry System

Enterphone Solo. User/Installation Manual Part No

CHAPTER 1. GETTING STARTED... 1

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Confer III Basic Operation

TECHNICAL. Smart Touch Tone Dialer with Redialing. K Touch Tone Dialer with Redialing

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

30+ YEARS! 2-Way Ringdown Circuits/Line Simulators Ideal for Inter-System Communication or Demos Y2K. 100 s of Products, 1000 s of Telecom Solutions!

Provide Door Entry and Keyless Entry for up to 250 Apartments or Offices

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

PAC1 Door Access Controller

AASTRA 9110 User Guide

DC-8706K Auto Dial Alarm System

DIGITAL TELEPHONE STATION USER QUICK REFERENCE GUIDE

Configuring the 930A for Common PBX Metallic Signaling Interfaces

Polycom SoundPoint 320/321 Quick Guide

TX3 Series TELEPHONE/CARD ACCESS SYSTEMS. System Introduction (Sales Training)

TECHNICAL. SLP-4 Single Line Paging Controller with CD Quality Westminster Chimes

HiPath 3000 HiPath AllServe

11/16/92 AT&T. AT&T Door Phone Controller. Installation and Operation Manual

Secure Keypads for access control

Tek-ENTRY Telephone Entry System

AA9604 Auto Attendant

TECHNICAL C-250. Single Entry Phone Controller with Call Forwarding and Door Strike Control

PagePac PAGEPAL V

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

9448 Installation and User Guide

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

PagePac Door Phone Controller V Installation and Operation Manual

G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Innovative DOOR STATION Solutions

Four-Line Intercom Speakerphone 944

Business/Home GSM Alarm System. Installation and User Manual

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

9452/9453 Installation and User Guide

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

-Helping to make your life betterwww.person-to-person.net

Digital Keypad Use s Manual

Telephone Controller INSTRUCTION MANUAL MODEL CT240-01

GLENSOUND ELECTRONICS LTD

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

User s Information Guide R1A

SINGLE-ZONE TELEPHONE INTERFACE

APPLICATION. Using the PB-100 to Make Calls and Announcements From a Database. Using the PB-100 for All-Call Dialing

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Features of Your Cisco Unified IP Phone

Installation Instructions

DirectCommand Installation DirectCommand 3-Channel Spreader Kit

Using your LED Plus keypad

Control & Monitoring Access Control. In today s world, access control is not an option, but an essential service.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

ontrol Control & Monitoring Access Control In today s world, access control is not an option, but an essential service.

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog.

Vista. Vista 150 User Guide

Model PBX 308 System Administration Guide

OfficeSuite Mitel IP Phone User Reference Guide Release 4.1

ACCESS CONTROL DOOR PHONES Installation and Programming Manual

TECHNICAL. Extend Your Phone System s Features and Forward Calls to Telecommuters. RAD-AMP Amplified Remote Access Device

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

ALCATEL 2315 USER GUIDE

INSTALLATION INSTRUCTIONS

AR-1. Digital Call Screening and Messaging System with 12 Minutes of Flash Memory. Automated Receptionist. Features. Applications.

User Guide for Cisco Unified IP Phones 7961G and 7941G

EQUIPMENT SPECIFICATIONS

GST301. (Single Protection Zone) Operation Manual

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

e-ask electronic Access Security Keyless-entry

ADEMCO LYNXR-I Security Systems

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

EP Line Intercom Speakerphone with Caller ID and Jumbo Pivoting Display

PRO PLM Installation Instructions

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

TS510 & TS500. Installation & User Guide. Compatible Equipment

PCM2000 Configuration Guide

Glolab Talking Phone Dial Monitor

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE

Printed in China. Issue 4 AT&T 12/11. Message Guard is a registered trademark of Advanced American Telephones.

1. Primary Phone Line 2. Programmable Button Indicators 3. Soft Key Labels 4. Status Line 5. Call Activity Area 6. Phone Tab 7.

Voice Dialer System & Power Monitor VD-5100-SM

Cloud Voice Service Cisco Unified IP Phone 6921 User Guide. (Version 1.0)

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

FAQs. XAP Frequently Asked Questions. Software/Configuration

SIP-T22P & SIP-T22 IP Phone

OPERATING INSTRUCTIONS

1838AP 1810AP PG. 48 PG. 42

AUTODIALLER / QUICKDIALLER - SA132

Feature Reference. Features: Call Forwarding Call Waiting Conference Calling Outbound Caller ID Block Last Call Return Voic

Polycom SoundPoint IP 650

CISCO IP 7962 Series QUICK REFRENCE

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

REMOTE TRANSMITTER LAYOUT

LCD -based Intelligent Burglar Alarm System. User Guide. Ver 2.0

Transcription:

TECHNICAL Practice TELECOM SOLUTIS FOR THE 21ST CENTURY C-1000A Do Entry Controller June 21, 2002 Features Allows two Viking doboxes paging amplifiers to share a single telephone line with a residential business telephone system Custom ringing mode allows you to distinguish dobox calls from C.O. calls Compatible with the following handsfree Viking models: W-1000, W-2000A, W-3000 Call waiting tones indicate which dobox is calling and distinguish a dobox call from a C.O. line call Calls can be placed on hold when visits call from the dobox when paging Provides two Touch Tone controlled N.O. N.C. dry contact closures (5 amp rating) f do strikes gate openers Compatible with pulse Touch Tone phones Postal lock/keyless entry input Built-in talk battery f No C.O. applications Auxiliary contact output f dobells, cameras, etc. Add Peripherals without Changing Your Phone System The C-1000A Controller dramatically expands the potential installation sites f many peripherals such as doboxes and paging amplifiers. Doboxes and paging amplifiers can now be used on single line, residential home office applications as well as on fully loaded systems, because they are no longer limited to installation on unused trunk pts. The C-1000A allows single line phones phone systems to share a phone line with one two doboxes paging amplifiers. In addition, the C-1000A provides two Touch Tone controlled relays to operate do strikes gate openers. Applications Add one two Viking Doboxes to your home office phones Add paging amplifiers to provide loud ringing and paging to businesses with single line phones fully loaded phone systems Provide commercial residential security via twoway handsfree communication from a do gate Use as a line concentrat (one fax machine answering machine can answer three lines) Phone...715.386.8861 info@vikingelectronics.com http://www.vikingelectronics.com Specifications Power: /13.8V AC 1.25A, UL listed adapter provided Dimensions: 133mm x 89mm x 44mm (5.25" x 3.5" x 1.75") Shipping Weight: 0.9 kg (2 lb) Environmental: 0 C to 32 C (32 F to 90 F) with 5% to 95% non-condensing humidity Do Strike Relay Contacts: 5A @ 30V DC/250V AC maximum Auxiliary Relay Contacts:.5A @ 125V AC, 1A @ 30V AC Connections: (2) RJ11 jacks, (1) 12 position terminal block Pulse Dialing Detection: 10 pps Talk Battery: 30V DC Maximum Dobox Power Supply Length: 100 ft, 24 awg wire

Installation and Applications A. One Two Doboxes Sharing a Phone Line See Operation, section A. 13.8V AC Adapter included ENTRY/PAGING BOX Open Closed Note: See Programming section G. 5A@30V DC/250V AC maximum Gate controllers do not typically require power. Dostrike/Magnetic Lock of W-1000 Unused Trunk Input of Gate controllers do not typically require power. Standard Analog Phones 5A@30V DC/250V AC maximum Dostrike/Magnetic Lock of W-2000A B. Using the C-1000A with Three Doboxes and No The C-1000A can be used to control up to 3 doboxes. If do/gate control is needed, the C-1000A must be used in combination with the RC-3 Remote Controller (Fax Back Document 165). In this configuration, the optional RC-3 is connected in parallel with dobox 3 to provide up to three additional relay contacts. Note: Dobox 3 will not have Touch Tone dialing restriction (security). Be sure to program the RC-3 and the C-1000A with different security codes. See Operation, section A. RC-3 Relay Controller 3 4 5 6 7 8 9 10 13.8V AC Adapter included Open ENTRY/PAGING BOX Closed Note: See Programming section G. 5A@30V DC/250V AC maximum Dostrike/Magnetic Lock Gate controllers do not typically require power. of W-1000 (Dobox 3) Do Strike 5 Do Strike 4 Do Strike 3 Unused Trunk Input of Analog Phone of W-1000 (2) 120VAC Gate controllers do not typically require power. 5A@30V DC/250V AC maximum Dostrike/Magnetic Lock of W-2000A

C. Using a C-1000A without a The C-1000A can also be used without a C.O. line. This is ideal f connecting the C-1000A to an unused trunk/line input of your phone system connecting to phones used only f dobox communication. 1. Connect the power, required doboxes, and dostrike outputs (if required) as shown in section A. 2. Connect an analog phone trunk pt to the PHES output of the C-1000A. 3. Be sure the is in the position. ENTRY/PAGING BOX D. Using the C-1000A with a Postal Lock/Keyless Entry Imptant: Electronic components are sensitive to static electricity. Personnel and the wk area should be grounded befe handling. International Electronics (800) 343-9502 3 4 5 6 7 8 9 0 Keyed Keyless Momentary Closure 1. Remove the C-1000A circuit board from the chassis. 2. Connect the postal lock to the two pin header J5 at the rear of the board and replace circuit board in the chassis. 3. Connect doboxes and dostrike outputs (if required) as shown in section A. 4. See Operation section A, 5. Postal Lock. Enter ENTRY/PAGING J5 BOX 2 1 E. Using the C-1000A to trigger a Camera Dobell 1. Connect the camera dobell (not included) as shown to the right. Note: The C-1000A will not supply power to the dobell, an adapter is necessary. 2. Connect doboxes and dostrike outputs (if required) as shown in sections A. 3. Program the Auxiliary Contact Output as desired (see Programming section B). ENTRY/PAGING BOX 4. See Operation section A, 6. Auxiliary Contacts. Dobell (not included) Camera (not included) Not to Exeed.5A @ 125V AC 1A @ 30V AC SECURITY (3)

F. Line Concentrat Mode (One Telcom Device Can Answer up to Three Lines) The C-1000A can be used as a line concentrat, allowing up to 3 separate C.O. lines to connect to one telcom device. 1. Connect as shown below. 2. Move DIP switch 3 to the position (see Programming section E). 3. Be sure the Talk Battery Switch is. 4. See Operation section C. 13.8V AC Adapter included Dip Switches 3 ENTRY/PAGING BOX Line 1 Fax Machine Answering Machine Standard Analog Phone Red Green Red Green Line 3 Line 2 G. Adding Paging to Homes and Small Businesses with Single Line Phones The C-1000A can be used to control a paging amplifier from a single phone line. The amplifier used must provide talk battery, such as the PA-2A (Fax Back Document 485) CPA-7B (Fax Back Document 455). If need be, a dobox a second paging amplifier may also be added to the C-1000A Dobox 2 terminals (see Installation section A). Note: The C-1000A must be programmed to be in the Paging Mode, 4 (see Programming section B and Operation section B). 13.8V AC Adapter included ENTRY/PAGING BOX PAGING/LOUD RINGING AMPLIFIER SYSTEM PAGING HUDS,WI 54016 RINGING Unused Trunk Input of Standard Analog Phones 13.8VAC RINGING BATTERY LINES FEED 1-3 4-6 MODEL PA-2A 3 4 5 (4)

Programming A. Accessing the Programming Mode 1. Accessing the Programming Mode Locally (Security Code Bypass Mode) a. Move DIP switch 2 from to (see Programming section E). b. Call into the C-1000A from a Touch Tone phone. Note: Call in from another line to avoid C.O. busy signals, etc. c. Answer the call using the device on the PHES pt. d. A double beep will indicate that you have accessed the programming mode. e. You can now Touch Tone program the features listed in section B below. f. When finished programming, move DIP switch 2 to the position. Note: Programming from a cell-phone may not be suitable in areas with weak coverage. 2. Accessing the Programming Mode Remotely a. Call into the C-1000A from a Touch Tone phone. Note: Call in from another line to avoid C.O. busy signals,etc. b. Answer the call using the device on the PHES pt. c. From either phone enter followed by the six digit security code (see Programming section D). d. A double beep will indicate that you have accessed the programming mode. e. You can now Touch Tone program the features listed in section B below. Note: Programming from a cell-phone may not be suitable in areas with weak coverage. Memy B. Quick Programming Features Enter Digits - then - Location Do strike 1 activation time.5-10 seconds (see Note below)... 2 digits (00-10) Do strike 2 activation time.5-10 seconds (see Note below)... 2 digits (00-10) Auxiliary contact activation time.5-10 seconds (see Note below)... 2 digits (00-10) Note: 00 =.5 seconds, 01-10 = 1-10 seconds, facty set to 00 (.5 seconds). Auxiliary contact latched while either dobox is activated... 11 Auxiliary contact activated in custom ring cadence... 12 Security Code (facty set to 845464)... 6 digits (0-9) Disable all special modes listed below (facty default)... 0 Dobell mode... 1 Custom ring mode... 2 Multiple relay activation mode... 3 Paging mode... 4 Inhibit latching commands mode... 6 To reset to facty settings... ### Note: Multiple modes may be selected. C. Programming Examples Enter Digits #01 #02 #03 #03 #03 #47 Programming the C-1000A... 1....to set do strike 1 to activate f 3 seconds 2....to set the auxiliary contacts to activate a camera while either dobox is activated 3....to set the auxiliary contacts to activate an external ringer strobe light in a custom ring cadence while either dobox is ringing 4....to have doboxes ring phones in a custom ring pattern Enter 03 #01 11 #03 12 #03 2 D. Security Code This six digit number can be used to access the programming mode. The security code has been facty set to 845464 (V-I-K-I-N-G). It is recommended that you change the security code to a personal 6 digit number. To change the security code, access programming (see Programming section A). Enter six digits 0-9 followed by #47. If you have fgotten your security code, follow the steps in Programming section A, 1. Accessing the Programming Mode Locally. Note: The security code must be six digits in length and can NOT contain a #. (5)

E. Dip Switch Programming Switch 1 2 3 Description Dostrike Activation Time Security Code Bypass Mode Mode Selection Operation -.5 seconds (facty setting) - 10 seconds - Nmal Mode (facty setting) - Security Code Bypass Mode - Line Concentrat Mode - Nmal Operation (facty setting) Dip Switches 3 ENTRY/PAGING BOX F. Mode Descriptions Entering these codes while in programming will switch the C-1000A into the cresponding mode. Disable Special Modes ( 0): This command disables (clears) all the special modes listed below. Enter this command befe programming the rest of the selections to be sure no unwanted modes are set. Dobell Mode ( 1): In this mode, the ring signal from either dobox is prevented from going through to the PHES pt. This is useful when a conventional do bell is connected to the auxiliary contacts. Now when someone activates a dobox, the dobell will chime rather than the phone ringing (see Programming section B). Custom Ring Mode ( 2): With this mode selected, the ring signal from the device pts are interrupted in a double burst pattern, making it easier to determine if the incoming call is from a dobox the C.O. line. Multiple Relay Activation Mode ( 3): If selected, after a do strike command is entered, the phone is switched back to the dobox pt so additional dostrike (relay activation) commands can be entered. This is useful when letting someone through your gate with the first command then unlocking your front dostrike with a second command. To return to the call on hold, enter #. Paging Mode ( 4): In this mode a paging system that provides talk battery (Viking PA-2A CPA-7B) can be connected to one of the dobox pts. When the person on the phone wants to make a page, they can enter # and a 1 2 depending on which pt the paging amplifier is on. After the announcement is made another # will return them to the phone conversation. Inhibit Latching Commands Mode ( 6): In some installations it is critical that the do strike do actuat not be turned on f long periods of time. To prevent this from happening, enter 6 when in programming. In this mode, the toggle command ( #) and the continuous activation command ( 1) are igned. G. N.O./N.C. Contact Selection Selection shunts are provided f each do strike relay and the auxiliary relay. Place the shunt in the left position f nmally open contacts, in the right position f nmally closed contacts. These shunts are located directly above the terminal block positions that they control. ENTRY/PAGING BOX Open Closed Operation A. Dobox Controller 1. Communicating with the Dobox a. Visit Initiated Call A visit pressing the Call button will cause the phones connected to the PHES pt to ring. Simply answer your phone to converse with the visit. (6) b. Moniting Doboxes A dobox may be monited from any phone connected to the C-1000A by Touch Tone dialing a # followed by a Touch Tone 1 2 to monit dobox 1 dobox 2 respectively. This feature is not available f pulse dialing phones. Note: Do not attempt dobox moniting while a call is in progress, the call will be disconnected. Note: When moniting, the auxiliary contact will only wk on the Continuous Mode (11).

2. Placing Calls on Hold If a C.O. line call is in progress and a dobox is activated, a single double call waiting tone will be heard indicating dobox 1 dobox 2 is calling. To place the in-progress call on hold and answer the calling dobox, simply dial a Touch Tone #, pulse dial a 2 hook flash twice. 3. Activating a Dostrike, Magnetic Lock Gate Controller To activate a relay contact, you must be communicating with a dobox. Simply Touch Tone dial, pulse dial a 3 hook flash three times. Two confirmation tones will be heard and the relay will be activated f the programmed dostrike activation time. The phone will then be returned to the C.O. line. If a call was in progress, the iginal caller will be taken off hold to continue the conversation. To return to the iginal call without activating a relay, Touch Tone dial #, pulse dial a 2 hook flash twice. 4. Features Activate dostrike relay 1 2... Pulse dial 3 hook flash 3 times Continuously activate dostrike relay 1 2... 1 Continuously de-activate dostrike relay 1 2... 0 Activate opposite dostrike relay... 2 Toggle relay from last position... # Answer disconnect a dobox call... # Pulse dial 2 hook flash 2 times Monit dobox 1... # 1 Monit dobox 2... # 2 6. Auxiliary Contacts The auxiliary contacts are a separate set of contacts that can be programmed (see Programming section B) to activate in different patterns when dobox 1 dobox 2 is off hook. A momentary activation, a continuous activation while the dobox is off-hook, and a ring cadence pattern are available. a. Timed Activation If an auxiliary contact activation time is programmed (two digits 00-10 followed by #03), when either dobox is activated, the auxiliary contacts will activate f the programmed time (.5-10 seconds). This is ideal f operating a dobell chime. b. Continuous Activation If the auxiliary contact is programmed to continuously activate (11 followed by #03), while either dobox is ringing off-hook, the auxiliary contacts will latch. This is ideal f controlling cameras, lights, etc. c. Ring Cadence Activation Touch Tone Commands Pulse Dial/Flash Commands Note: When on the C.O. line, if a Touch Tone other than # is entered, any additional Touch Tones in that dial string will be igned. To regain control of the C-1000A, the phone must be momentarily placed on-hook. 5. Postal Lock/Keyless Entry When a momentary postal lock contact closure is made across pins JP5 (see Installation section D), the dostrike 1 contact will activate f the programmed time. If the auxiliary contact is programmed to custom ring cadence ( 12 #03 ) when dobox 1 is activated, a repeating 1 second on and 3 seconds off contact pattern is generated. If dobox 2 is activated, a repeating double burst contact pattern is generated with 3 seconds off between patterns. B. Paging Controller In this mode a paging system that provides talk battery (Viking PA-2A CPA-7B) can be connected to one of the dobox pts. When the person on the phone wants to make a page, they can enter # and a 1 2 depending on which pt the paging amplifier is on. After the announcement is made, if a call was in progress, another # will return them to the phone conversation. C. Line Concentrat The first ringing line will ring to the PHE pt of the C-1000A. On outbound calls, the C-1000A will default to the primary line (line connected to the Line In pt). To access the lines connected to Dobox 1 pt Dobox 2 pt, simply dial Touch Tones #1 #2 respectively. Note: DIP switch 3 must be in the position. (7)

Do Boxes These Viking doboxes are designed to be installed on the unused telephone line input of nearly any phone system. When the Call button is pressed, the dobox generates a standard ring cadence f an adjustable number of rings. To converse with the visit, the inside party simply answers the call from the phone of their choice. F noisy environments, the dobox s pushto-talk feature may be used. W-1000 The flush mount W-1000 dobox is made of black powder painted aluminum. The surface mount W-2000A dobox is made of UV resistant plastic. The flush mount W-3000 dobox is made of vandal and weather resistant stainless steel. The W-1000 and W-3000 may be surface mounted using Viking s VE-5x5 backbox. F me infmation on the VE-5x5, retrieve Fax Back Document 424. Fe me infmation on the W-1000 W-2000A, retrieve Fax Back Document 170. F me infmation on the W-3000, retrieve Fax Back Document 180. W-2000A W-3000 with VE-5x5 Advanced Do Entry The C-2000 allows up to 4 entry phones to call into your existing residential business phones phone system. Tenants may answer the call, converse with the visit and activate a contact closure to control electronic gates do strikes. The C-2000 provides Caller ID, Call Waiting ID and Call Waiting tones when the phone line is in use. Tenants may gain entry at each gate by entering a Touch Tone keyless entry code. Create an advanced do entry system by using the C-2000 in combination with the K-1700-3 handsfree phone. The K-1700-3 features a vandal and weather resistant stainless steel faceplate with a heavy duty keypad. The K-1700-3 comes complete with a standard, flush mount, rough-in box. In addition, the K-1700-3 may be surface mounted using Viking s VE-6x7 backbox. F me infmation on the VE-6x7, retrieve Fax Back Document 424. K-1700-3 F me infmation on the C-2000, retrieve Fax Back Document 156. F me infmation on the K-1700-3, retieve Fax Back Document 157. C-2000 K-1700-3 with VE-6x7 Product Suppt Line...715.386.8666 Fax Back Line...715.386.4345 Due to the dynamic nature of the product design, the infmation contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/ subsidiaries assume no responsibility f errs and omissions contained in this infmation. Revisions of this document new editions of it may be issued to incpate such changes. Fax Back Doc 155 (8) Printed in the U.S.A. ZF301500 Rev A