Thyristor-controlled power supplies and battery chargers



Similar documents
DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

RIELLO ELETTRONICA. Master HP

Quick Connect. quick - simple - efficient.

MPR-Systems. Mini Power Racks 1200 W W

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Technical data UNIBLOCK UBSF

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

BB800 Off-Grid Solar System

MAJORSINE Power Inverter

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Low and High Voltage Power Supplies

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

EGSTON Standard E2xFxWx 12W

4.0 UPS dedicated to ICT for unmatched energy savings

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

TOSHIBA G /100/160/225 kva

Phase Modular Finally the benefits of Modular ups are for all

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Power Supplies 3. SDN-P DIN Rail Series

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PowerGem Pro Uninterruptible Power Supply

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

TRAMS TROLLEY-BUSES SUBWAY

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Technical Data. back-up time in minutes 100% load % load

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Operating Manual UWAPS-TINY Series

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DC Electronic Loads 8500 series

UMEC International Corporation

TMS TANK MANAGEMENT SYSTEM

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

ST Series POWER SUPPLIES USER INSTRUCTIONS

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

Multi-Range Programmable DC Power Supplies 9115 Series

Research RF Sputtering Packages

Multi-Range Programmable DC Power Supplies 9115 Series

Data Sheet. Electro-mechanical counters Hengstler 800 series

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

HERZ-Thermal Actuators

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

User s Manual Before using the inverter, you need to read and save the safety instructions.

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

1.44 kw Programmable DC Power Supplies XLN Series

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

FIREDEX Conventional Fire Panels

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

DCS Series 1 kw, 1.2 kw, & 3 kw

Phone: Fax: Web: info@clrwtr.com

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

GTEC transfer switch open transition

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

A project to optimise quality and energy efficiency must include metering

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Installation manual. Generator Paralleling Controller GPC multi-line C

Actuator-Sensor-Interface

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

User s Manual AURORA 1.2K/2.2K

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

instabus KNX / EIB System System E F G H

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

Transcription:

Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 / 110 / 220 / 400 VDC Output current: up to 3250 A Output power: 100 W - 500 kw The thyristor-controlled power supplies and battery chargers present the conventional method of rectifying and controlling electric power. The advantages of thyristor-controlled units are given by a simple technical concept resulting in robustness and reliability. Typical applications Power stations Sub-stations Switch gear stations Chemical plants Railway on-board Railway trackside Pipeline systems Hospitals Depending on the application, nickelcadmium batteries, flooded or valve regulated lead-acid batteries are used for energy storage in the power supply system. Each type of battery requires an individual charging characteristic which can be accomplished by the control cards. In addition, there is a number of options and accessories for individual configuration of the charger system. 104

Thyristor-controlled power supplies and battery chargers Specifications Input Voltage.................... 230 VAC ±10 %, 1-phase or 400 VAC ±10 %, 3-phase (other voltages upon request) Frequency................. 50 or 60 Hz ±5 % Current.................... see table Protection.................. by fuse Output Nominal voltage............ see table (other voltages upon request), adjustable from 90 120 % of U nom Line regulation (±10 %)...... ±0.5 % Load regulation (10 90 %)... ±1 % Dynamic load (10-90 - 10 %).. ±10 % typical Ripple..................... 5 % rms without battery, optional: < 2 % rms or 2 mv frequency weighted Nominal current............ see table, electronic current limitation adjustable from 60 105 % of I nom Overload protection......... short circuit protected by fuse, optional: by electronic fuse Charging characteristic....... IU acc. to DIN 41773 for Pb batteries / DIN 41774 for NiCd batteries Charging voltage - float..................... 2.23 2.27 V/cell for Pb batteries / 1.4 V/cell for NiCd batteries - equalize.................. 2.35 2.4 V/cell for Pb batteries / 1.55 V/cell for NiCd batteries - boost (manual activated).... 2.7 V/cell for Pb batteries / 1.7 V/cell for NiCd batteries General Efficiency - Series QE................. 78 90 % - Series QD................. 82 92 % for models < 48 VDC 85 97 % for models 48 VDC Operating temperature....... 10 to + 40 C, optional up to + 65 C Humidity.................. up to 95 % RH, non-condensing Altitude................... up to 1000 m asl Cooling................... natural convection Audible noise............... 50 70 db(a) depending on power Safety / Construction......... acc. to DIN / EN 60950-1: 2003 EMI....................... acc. to EN 55022, class A Enclosure - Protection category......... IP20 acc. to EN 60529, optional up to IP55 - Color.................... RAL 7035, others upon request Transformer................ acc. to IEC 76 / IEC 14 / EN 60591 / DIN VDE 0532 Thyristor-controlled power supplies and battery chargers Page Series QE, thyristor-controlled rectifiers with 1-phase input 106 Series QD, thyristor-controlled rectifiers with 3-phase input 107 Options & Accessories 108 Control & Supervision 109 Output voltage stabilization 110 105

Series QE with single phase input, 100 W 5 kw Q1 F1 L1 N T1 THYRISTOR CONTROL V1 V2 V3 V4 L1 R5 A P5 A1 C1 F4 F6 P6 V Model designation (example): QE 24 / 20 L- - BATTERY L+ + BATTERY F31 F32 1L- 1L+ DC-LOAD single phase input nominal output voltage [V] nominal output voltage approx. line enclosure 12 V 24 V 48 V 60 V 110 V 220 V current size 1) 2) [A] R2 R3 R4 R5 R5+ approx. weight 3) [kg] 4 2.5 1.2 1 0.6 12 6 4 2.5 2 1 1 14 9 6 1.4 15 12 8 4 3.5 2 1 1.6 18 16 11 2 22 22 14 7 6 3.2 1.6 2.7 26 30 20 10 8 5 2.5 4 28 36 25 12.5 10 6 3 5 31 50 32 16 14 8 4 6.5 40 60 40 20 18 10 5 8 46 80 55 30 25 14 7 11 60 110 75 40 35 18 9 15 73 100 55 45 25 12.5 20 88 130 70 60 32 16 26 98 1) Larger size may be required for optional equipment. 2) Line current is referred to nominal input voltage of 230 VAC. 3) Weight is referred to thyristor-controlled rectifier on a mounting plate without enclosure. Enclosures wall-mounted weight height width depth enclosure (empty) designation [kg] dimensions [mm] R2 9 300 380 R3 12 380 210 R4 17 R4+ 26 R4T 22 380 R5 31 R5+ 38 760 350 floor-mounted enclosure designation weight (empty) [kg] height* width depth dimensions [mm] R6 66 1200 R6+ 80 800 400 R7 127 1800 R7+ 150 800 R8 147 500 R8+ 175 2000 800 R9 250 1200 *) The height of the base frame, elevated roof and suspension eyes is to be added, if needed. 106

Series QD with 3-phase input, 1 500 kw L1 L2 L3 F1-F3 Q1 T1 THYRISTOR CONTROL V1 V2 V3 V4 V5 V6 A1 L1 R5 A P5 C1 F4 F6 P6 V Model designation (example): QD 60 / 32 L- - BATTERY L+ + BATTERY F31 F32 1L- 1L+ DC-LOAD three phases input nominal output voltage [V] nominal output voltage approx. line enclosure 24 V 48 V 60 V 110 V 220 V current size 1) 2) [A] approx. weight 3) [kg] R4 25 12 10 5 2.5 1.1 48 40 20 16 8 4 2 62 60 30 25 12 6 3 74 R5 80 40 32 16 8 4 78 100 50 40 20 10 5 85 R5+ 125 60 50 25 12 6 95 R6 160 80 65 32 16 8 130 200 100 80 40 20 10 150 R6+ 240 120 100 50 25 11 180 300 150 120 60 30 14 260 R7 350 170 140 70 35 16 310 400 200 160 80 40 19 340 R7+ 500 250 200 100 50 24 390 300 240 120 60 28 420 R8 700 350 280 140 70 33 450 R8+ 800 400 320 160 80 38 510 R9 1000 500 400 200 100 48 620 1200 500 250 120 57 680 1 800 300 150 76 740 2 x R8+ 2000 1000 800 400 200 95 780 2250 1125 900 500 250 120 920 2750 1375 1100 300 142 1000 3250 1625 1300 700 350 166 1180 1800 1450 800 400 190 1300 2 x R9 2250 1800 1000 500 238 1450 2750 1500 750 356 1630 3 x R9 2000 1000 475 1875 4 x R9 2000 950 2390 1) Larger size may be required for optional equipment. 2) Line current is referred to nominal input voltage of 3 x 400 VAC. 3) Weight is referred to thyristor-controlled rectifier on a mounting plate without enclosure. 107

Options & Accessories Input MCB, MCCB or isolator soft-start Output parallel operation redundant operation overload protection by electronic fuse 6 or 12-pulse performance filtering up to 0.1 % pp (corresponding to 0.035 % rms) or 2 mv frequency weighted voltage stabilization Control IU characteristic acc. to DIN 41773 and 41774 manual selection of charging characteristic (float / equalize / boost) automatic selection of charging characteristic with timer temperature compensated charging voltage Supervision analog or micro-processor-controlled input voltage output voltage battery circuit ground insulation failure over temperature fuses Interface card RS 232 for supervision Battery MCB, MCCB or isolator deep discharge protection DC distribution panel wired acc. to customer s specification Mechanics / environment enclosures, IP 20 up to IP 55, for charger and / or batteries analog or digital meters operating temperature up to 65 C (standard 10 to +40 C) tropical protection earthquake-proof vermin-proof Converters and Inverters switchmode DC/DC converters from 50 W to 30 kw switchmode DC/AC inverters, frequency converters and static switches from 200 VA to 30 kva 108

Control & Supervision Control Thyristor-controlled units provide constant output voltage with current limiting according to the IU characteristic: voltage 3 2 1 voltage limiting (boost charging) equalize charging float charging Supervision The charger and battery may be monitored through the use of a variety of plug-in design Supervision Cards. They have LEDs to indicate alarm detection. Additionally, a LED panel is available, typically mounted on the front door of the enclosure. Potential free contacts are provided for remote alarm. A timer circuit for delaying the alarm, or an electronic memory for storing the alarm until it is reset, by pressing a push button, is optionally available. current current limiting boost charging current a Curve 1 shows Constant Voltage / Constant Current operation, both values are adjustable by trim-potentiometer. b Curve 2 shows Equalize Charge operation with the constant voltage level increased by a certain amount, adjustable by trim-potentiometer. This mode of operation is started manually by pressing a push button or automatically, when the battery voltage has dropped below a certain level. It is terminated manually or by electronic timer. c Curve 3 shows Boost Charge operation with the current programmed by a knob and with adjustable voltage limiting. It is started manually only, as attention must be paid not to overcharge the battery. It is terminated manually or by electronic timer. If the voltage limit is reached the charger operates with constant voltage while the current decreases with the battery being filled up more and more. Additionally, the charger can be equipped with the option temperature compensated charging voltage. In case of high battery temperature the charging voltage will be automatically reduced. Supervised Alarm Alarm Criteria / Utilization Input Mains Voltage of one or more phases drops below an adjustable level. Output Battery Ground Insulation DC High Voltage DC Low Voltage Charger Battery Circuit Ground Insulation Temperature Over Temperature Fuse DC Fuse Load or battery voltage exceeds an adjustable level. The alarm signal can be used to INHIBIT (turn off) the charger or for disconnecting the load by means of a contactor. Battery voltage drops below an adjustable level. In order to avoid deep discharge of the battery, a contactor could be activated for disconnecting the load. No current flows at low battery voltage. Deviation of voltage symmetry of two battery sections with respect to a centre point. An initial asymmetry can be compensated by adjustment. The circuit detects conditions such as short circuit of cells, line interruption or poor quality connections between cells. Current from the positive or negative pole to ground exceeds an adjustable level, typically ±4 ma. High temperature may be sensed externally, internally or at semiconductors. Voltage drop across the charger output fuse, capacitor fuse or load fuse exceeds a certain value. 109