SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS



Similar documents
AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

Principles of Adjustable Frequency Drives

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Unit 33 Three-Phase Motors

Motor Fundamentals. DC Motor

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

Baldor Electric Position on DOE Small Motor Rule

FREQUENCY CONTROLLED AC MOTOR DRIVE

Electric Motor Brake Horsepower Calculations

DIRECT CURRENT GENERATORS

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

chapter6 Electrical machines and motors Unit 1 outcome 6

Rotary Phase Converters

Understanding the Alternator

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

AC Induction Motor Slip What It Is And How To Minimize It

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Specifying a Variable Frequency Drive s

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

Lab 14: 3-phase alternator.

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

What Is Regeneration?

Fundamentals of Inverter Fed Motors

Digi-Motor Installation Guide

Single-Phase AC Synchronous Generator

Introduction. Upon completion of Basics of AC Motors you should be able to:

Synchronous motor. Type. Non-excited motors

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Line Reactors and AC Drives

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

8 Speed control of Induction Machines

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

TERMINAL MARKINGS AND CONNECTIONS PART WINDING START

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Induction Motor Theory

Chen. Vibration Motor. Application note

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

AC Generators and Motors

DC Motor control Reversing

Power Plant Electrical Distribution Systems

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION

The Ultimate Truck Stock Motor

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

We will discuss common industrial applications with guides for the proper use of electric motors on these.

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

ELECTRIC MOTORS. Energy Efficiency Reference Guide STATOR POLE COMMUTATOR LINE

This slide is hidden. It will not show up during presentation.

TERMINAL MARKINGS AND INTERNAL WIRING DIAGRAMS SINGLE PHASE AND POLYPHASE MOTORS MEETING NEMA STANDARDS

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

Motors and Generators

8022-0E Motor Winding Kit

Basics of Electricity

WIND TURBINE TECHNOLOGY

Energy Savings Potential and Opportunities for High-Efficiency Electric Motors in Residential and Commercial Equipment

How To Make A High Efficiency Thermostat

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

WHITE PAPER. DC Motors Explained. DC Motors Explained: White Paper, Title Page

Low Profile Unit Cooler

Basic Nameplate Information

Test Code: 8094 / Version 1

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Inverter technology. bulletin

Data Sheet. AC Industrial Electric Motors

PHASE CONVERSION TECHNOLOGY OVERVIEW

SYNCHRONOUS MACHINES

Welcome to Linear Controls Quarterly Training

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

SHIP SERVICE GENERATORS (AC)

How To Understand And Understand The Electrical Power System

E2 Series Electric Furnaces

VARIABLE FREQUENCY DRIVES THEORY, APPLICATION, AND TROUBLESHOOTING

Contactor and Starter Ratings

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

SECTION VARIABLE FREQUENCY DRIVES

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

FASCO FACTS TIME-SAVING MOTOR REPLACEMENT TIPS

, User s Manual

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Outline. Turbine Generators. Generator History 3/25/2014

INTRODUCTION TO RATIOTROL

Application Information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Section 10. Application Manual for NEMA Motors. Special Applications

Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry

ELECTRICAL ENGINEERING Vol. III - Induction Motor and Self-Excited Induction Generator - Tze-Fun Chan

Understanding Variable Speed Drives

1. The diagram below represents magnetic lines of force within a region of space.

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Electronically Controlled Clutchless or Variable Drive Compressors

Reversing starter circuit for single phase induction motors Updated 1 st September 2008

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

BRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5

Transcription:

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive fans, compressors, and pumps. Describe the applications of the various types of motors. State which motors have high starting torque. List the components that cause a motor to have a higher starting torque. Describe a multispeed permanent split-capacitor motor and indicate how the different speeds are obtained.

UNIT OBJECTIVES After studying this unit, the reader should be able to Explain the operation of a three-phase motor. Describe a motor used for a hermetic compressor. Explain the motor terminal connections in various compressors. Describe the different types of compressors that use hermetic motors. Describe the use of variable-speed motors.

USES OF ELECTRIC MOTORS Used to turn fans, pumps and compressors Facilitate the circulation of air, water, refrigerant and other fluids Motors are designed for particular applications The correct motor must always be used Most motors operate on similar principles

Fans are used to move air Pumps are used to move liquids

PARTS OF AN ELECTRIC MOTOR Stator with motor windings Stationary portion of the motor Rotor Rotating portion of the motor Bearings Allow free rotation of the motor shaft End bells Supports the bearings and/or shaft Housing Holds all motor components together and facilitates motor mounting

Housing and Stator Electrical Connections Rotor End Bell Mounting Base Shaft Parts of an electric motor

ELECTRIC MOTORS AND MAGNETISM Electricity and magnetism are used to create rotation Stator has insulated windings called run windings Rotor may be constructed of bars Squirrel cage rotor Positioned between the run windings Rotor turns within the magnetic field

Magnet supported from above N S N S Since unlike poles repel each other, the magnet will rotate Stationary Magnet

N S Stationary Magnet

N S Stationary Magnet

N N S S Stationary Magnet

N S Stationary Magnet

N S Stationary Magnet

S N When the unlike poles are lined up with each other, rotation will stop N S Stationary Magnet

DETERMINING MOTOR SPEED As the number of poles increases, the motor speed decreases Motor Speed (rpm) = Frequency x 120 # of poles In the United States the frequency is 60 Hz For example, a 2 pole motor will turn at a speed of 60 x 120 2 = 7200 2 = 3600 rpm The motor will turn at a speed that is lower than the calculated value Slip = difference between calculated and actual motor speed

THE START WINDING Enables the motor to start and in the right direction Start winding has higher resistance than the run winding Wound with more turns than the run winding Wound with smaller diameter wire than the run winding Removed from the active circuit once the motor starts

STARTING AND RUNNING CHARACTERISTICS Refrigeration compressors have high starting torque Starting torque twisting force that starts the motor Locked Rotor Amperage (LRA) Full Load Amperage (FLA) Rated Load Amperage (RLA) Motor may start with unequal pressures across it Small fans do not require much starting torque

ELECTRICAL POWER SUPPLIES Residences are furnished with single-phase power Houses can be supplied power from the transformer Power feeds into circuit breaker panel or fuse box Circuit breakers protect each individual circuit Power is distributed throughout the house Typical residential panels provide 115 and 230 volts Commercial and industrial facilities require three-phase power

Individual 115-volt circuits with 115-volt, single-phase circuit breakers L1 L2 Main Circuit Breakers 230-volt two-pole circuit breakers and 230-volt circuits Neutral and Ground Bus RESIDENTIAL CIRCUIT BREAKER PANEL

SINGLE-PHASE OPEN MOTORS Residential motors operate at 115, 208 or 230V Commercial motors operate at voltages up to 460V Some motors are designed to operate at one of two different voltage (dual voltage motors) Dual voltage motors are wired differently for each voltage Some motors have reversible rotations

DUAL VOLTAGE MOTOR (230-VOLTS) Start Winding Starting Switch Run Windings 230-volt power supply Run windings are wired in series with each other for high- voltage application

DUAL VOLTAGE MOTOR (115-VOLTS) Start Winding Starting Switch Run Windings 115-volt power supply Run windings are wired in parallel with each other for low-voltage applications

SPLIT-PHASE MOTORS Two separate motor windings Good running efficiency Medium amount of starting torque Speed typically ranges from 1800 3600 rpm Motor speed is determined by the number of poles Slip is the difference between the calculated and actual motor speeds

START WINDING Small Wire Large Number of Turns High Resistance L1 RUN WINDING Larger Wire Small Number of Turns Low Resistance L2

120 Volts RUN Rotor START START RUN

THE CENTRIFUGAL SWITCH Commonly used on open motors to de-energize the start winding Opens its contacts when the motor reaches about 75% of its rated speed When the contacts open and close, a spark is created (arcing) Not used in a refrigerant atmosphere

START WINDING Small Wire Large Number of Turns High Resistance THE CENTRIFUGAL SWITCH L1 RUN WINDING Larger Wire Small Number of Turns Low Resistance L2

CAPACITOR-START MOTOR Split phase motor with start and run windings Start capacitor assists the motor starting by increasing the starting torque Start capacitor is wired in series with the motor s start winding Start capacitor is removed from the circuit when the start winding is removed Start capacitor increases the phase angle

CAPACITOR-START MOTOR L1 START START CAPACITOR RUN L2

PHASE ANGLE Number of electrical degrees between the current and the voltage In a resistive circuit the current and voltage are in phase with each other and the phase angle is zero The current can lead or lag the voltage In inductive circuits, the current lags the voltage In capacitive circuits, the current leads the voltage

CAPACITOR-START, CAPACITOR-RUN MOTOR Most efficient single-phase motor Often used with belt-driven fans and blowers Run capacitor improves running efficiency Run capacitor is in the circuit whenever the motor is energized Start and run capacitors are wired in parallel Motor amperage will rise if run capacitor goes bad

CAPACITOR-START, CAPACITOR-RUN MOTOR (CSCR) RUN CAPACITOR START CAPACITOR L1 L2

PERMANENT SPLIT CAPACITOR (PSC) MOTOR Simplest split-phase motor Only a run capacitor is used Low starting torque and good running efficiency Can be single or multispeed motors Multispeed motors have leads for each speed As the resistance decreases, motor speed increases As the resistance increases, motor speed decreases

PERMANENT SPLIT CAPACITOR MOTOR (PSC) RUN CAPACITOR L1 L2

SHADED-POLE MOTOR Very low starting torque Not as efficient as the PSC motor A portion of the run winding is shaded to provide the imbalance in magnetic field that allows the motor to start Heavy copper wire or bands are used to shade the run winding Manufactured in the fractional horsepower range

THE SHADED POLE MOTOR COIL BANDS OF HEAVY COPPER LAMINATED CORE ROTOR

THREE-PHASE MOTOR Normally used on commercial applications Must have a three-phase power supply Powered by three single-phase power supply legs Has no start winding or capacitors Very high starting torque Rotation of motor can be changes by switching any two power legs

THREE-PHASE 220-VOLT POWER SUPPLY L1 L2 L3 THESE THREE POWER SUPPLIES ARE GENERATED 120 DEGREES OUT OF PHASE WITH EACH OTHER

SINGLE-PHASE HERMETIC MOTORS Hermetically sealed from outside air Similar to single-phase motors Use relays to remove start winding from circuit They do not use centrifugal switches Often use run capacitors for increased efficiency Designed to operate in a refrigerant atmosphere Motor terminals identified as common, start & run

THE POTENTIAL RELAY Used on motors requiring high starting torque Coil with very high resistance Normally closed contacts Relay operates on the induced voltage across the start winding The contacts open when the induced voltage rises When the motor turns off, the induced voltage drops and the relay contacts close

2 THE POTENTIAL RELAY 1 5 Normally close contacts connected between terminals 1 and 2 Coil connected between terminals 2 and 5

CAPACITOR-START, CAPACITOR-RUN MOTOR (CSCR) 5 2 1 START CAPACITOR L1 RUN CAPACITOR L2

THE CURRENT RELAY Used on fractional horsepower motors Used with fixed-orifice metering devices Low resistance coil in series with the run winding Normally open contacts in series with start winding Upon startup only the run winding is energized The motor draws locked rotor amperage The increased amperage closes the relay contacts The start winding is energized and the motor starts The amperage drops and the relay contacts open

START WINDING Small Wire Large Number of Turns High Resistance THE CURRENT MAGNETIC RELAY (CMR) L1 RUN WINDING Larger Wire Small Number of Turns Low Resistance L2

POSITIVE TEMPERATURE COEFFICIENT (PTC) START DEVICE Thermistors change resistance with changes in temperature During startup, the resistance of the PTC is about 4 to 10 ohms As the motor operates, current flow generates heat that causes the resistance to increase Resistance can increase to 10,000 to 12,000 ohms

TWO-SPEED COMPRESSOR MOTORS Used to control the capacity of compressors Speed changes are obtained by wiring changes The thermostat controls the wiring changes Considered to be two compressors in one housing One motor turns at 1800 rpm, the other at 3600 Two-speed compressors have more than three motor terminals

SPECIAL APPLICATION MOTORS Some single-speed motors have more than three motor terminals Some have auxiliary compressor windings to increase the motor efficiency Some motors have winding thermostats wired through the compressor shell Three-phase motors have one thermostat for each winding The winding thermostats are wired in series

THREE-PHASE COMPRESSOR MOTORS Used in large commercial/industrial applications Normally have three motor terminals No capacitors are required Resistance across each winding is the same Three-phase motors have high starting torque Some larger three-phase compressor motors operate as dual voltage device

VARIABLE SPEED MOTORS Motor speed decreases during low load conditions Voltage and frequency determine motor speed New motors are controlled by electronic circuits Variable speed direct current (dc) motors Electronically commutated (ECM) dc motors Motors can ramp up or down to reduce motor wear AC current can be converted to DC using rectifiers

DC CONVERTERS (RECTIFIERS) Phase-controlled rectifier Converts ac power to dc power Uses silicon controlled rectifiers and transistors Capacitors smooth out the dc voltage Diode bridge rectifier Does not regulate the dc voltage Diodes are not controllable Voltage and frequency are adjusted at the inverter

INVERTERS Vary the frequency to obtain the desired speed Six-step inverter Receives voltage from the converter Can control the voltage or the current Pulse width modulator (PWM) Receives fixed dc voltage from the converter Voltage is pulsed to the motor Short pulses at low speed, long pulses at high speed

ELECTRONICALLY COMMUTATED MOTORS (ECM) Used on open drive fans less than 1 hp Armature is commutated with permanent magnets Motors are factory calibrated Two-piece motor: motor section and controls Motor can be checked with an ohmmeter Controls can be checked with a test module Defective controls can be replaced

COOLING ELECTRIC MOTORS All motors must be cooled Hermetic compressor motor are cooled by air and refrigerant Open motors are cooled by air Open motors must be located where there is a good supply of air Some very large motors are cooled by water

UNIT SUMMARY - 1 Motors facilitate the circulation of air, water, refrigerant and other fluids Some applications require high starting torque Motor components include the housing, rotor, stator, end bells, bearings and motor mount Electricity and magnetism create motor rotation Motor speed is determined by the number of poles The start winding has higher resistance than the run winding Important motor amperage are LRA, FLA and RLA

UNIT SUMMARY - 2 Residences are supplied with single-phase power Some motors are designed to operate at more than one voltage Split phase motors have a medium amount of starting torque and good running efficiency The centrifugal switch opens and closes its contacts depending on the speed of the motor The current relay opens and closes its contacts depending on the current flow through the run winding

UNIT SUMMARY - 3 The potential relay opens and closes its contacts depending on the induced voltage across the start winding Capacitor start motors use start capacitors to increase the starting torque of the motor The start winding and start capacitor are removed from the circuit after the motor starts Capacitor start, capacitor run motors use both start and run capacitors Run capacitors help increase the motor s running efficiency

UNIT SUMMARY - 4 The PSC motor uses only a run capacitor The shaded pole motor has very low starting torque Three-phase motors are used for commercial and industrial applications The PTC and NTC are electronic device that change their resistance as the sensed temperature changes Variable speed motors ramp up and down, often using dc converters, inverters and rectifiers ECM motors are commutate with permanent magnets