SIMATIC. PC Adapter USB. Preface, Contents Properties of the. PC Adapter USB. Package Components 2



Similar documents
SIMATIC. PC Adapter USB. Preface, Contents Properties of the PC Adapter USB 1. Package Components

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Universal Serial Bus (USB) to DH-485 Interface Converter

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Kvaser Mini PCI Express User s Guide

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

USB-to-Data Highway Plus Cable

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

CompactLogix Power Supplies Specifications

TX OPEN RS232/485 module

SIMATIC. Programming device SIMATIC Field PG M2. Introduction. Description 2. Application Planning 3. Setting up and connecting 4. Startup 5.

Digital input modules

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

SIMATIC PDM V6.0. Getting Started Edition 12/2004

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

1 Application Description Objective Goals... 3

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

MACTek Corporation. USB HART Interface. Users Manual

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Modular I/O System Analog and Digital Interface Modules

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

SIMATIC HMI. WinCC flexible Getting Started First Time User. Order number 6ZB5370-1CL02-0BA2. Edition 04/2006 A5E

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

AXIS T81B22 DC 30W Midspan

Safety Precautions WARNINGS

1788 Linking Device Specifications

USB VoIP Phone Adapter. User s Manual

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Waveguide Access Point WGA631. Product Guide

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

AXIS 5810 A Bluetooth Print Plug. Quick Start

NX safety stand-alone

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Automation License Manager

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

USB Fieldbus Interface

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

MINI MCR-SL-R-UI(-SP)

PCAN-ISA. CAN Interface for ISA. User Manual

SIMATIC NET. Installation Instructions. INSTALLATION INSTRUCTIONS for the CP 5412 (A2) C79000-Z8974-C Stand / Dated 04/98

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

Installation instructions CAN/RS232-USB interface CANfox EC / / 2010

1-Port R422/485 Serial PCIe Card

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

SIMATIC NET. DP Base Programming Interface for CP 5613/CP Preface, Contents. Basic Steps in Creating a DP Application 1

ABB Drives. User s Manual HTL Encoder Interface FEN-31

R60 USB to CAN interface Manual (1.5 EN)

MADRIX NEO Quick Start Guide & User Manual

PCAN-USB CAN Interface for USB. User Manual. Document version ( )

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

A6210 WiFi USB Adapter ac USB 3.0 Dual Band User Manual

PT Mbps Powerline Adapter. User Guide

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

Telephone- and leased line modem for industrial applications TD-36

is then retained absolutely without interruption.

PCS0100en Persy Control Services B.V. Netherlands

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

User s Manual. Powerline 200M Ethernet Bridge

HMI display Installation Guide

1756 ControlLogix Chassis Specifications

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

User Manual Revision English

SCADAPack E ISaGRAF 3 User Manual

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

User Manual Revision English

Operating Instructions (Compact) Edition 02/2006

SIMATIC Field PG. Getting Started Edition 01/2002

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

BK MIKRO9. Tool monitoring system. Getting Started with Profibus Release 1.00 /

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

1 Application Description System Topology Hardware and Software Requirements... 3

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

USB 2.0 to 10/100Mbps Ethernet Adapter UE User Manual

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Transcription:

s SIMATIC Manual Preface, Contents Properties of the 1 Package Components 2 Requirements for Operation 3 Hardware Design of the 4 Working with the 5 on the MPI/DP Network 6 Firmware Update 7 Error Diagnostics 8 Technical Data 9 Appendices Certificates, Directives and Declarations Certification for the USA, Canada and Australia Index A Edition 01/2004 A5E00166353-03

Safety Guidelines This manual contains notices intended to ensure personal safety, as well as to protect the products and connected equipment against damage. These notices are highlighted by the symbols shown below and graded according to severity by the following texts:!!! Danger indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken. Warning indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken. Caution indicates that minor personal injury can result if proper precautions are not taken. Caution indicates that property damage can result if proper precautions are not taken. Notice draws your attention to particularly important information on the product, handling the product, or to a particular part of the documentation. Qualified Personnel Only qualified personnel should be allowed to install and work on this equipment. Qualified persons are defined as persons who are authorized to commission, to ground and to tag circuits, equipment, and systems in accordance with established safety practices and standards. Correct Usage Note the following:! Warning This device and its components may only be used for the applications described in the catalog or the technical description, and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. This product can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended. Trademarks SIMATIC, SIMATIC HMI and SIMATIC NET are registered trademarks of SIEMENS AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners. Copyright Siemens AG 2003-2004 All rights reserved The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens AG Bereich Automation and Drives Geschaeftsgebiet Industrial Automation Systems Postfach 4848, D- 90327 Nuernberg Siemens Aktiengesellschaft Disclaimer of Liability We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed. Siemens AG 2003-2004 Technical data subject to change. A5E00166353-03

Preface Purpose of the Manual This manual gives you a complete overview of. It guides you when installing and commissioning the software and hardware. It also describes the operation and hardware installation requirements, as well as, the connection of the Adapter to MPI/DP networks. This manual is intended for the programmers and for those responsible for configuring, commissioning, and servicing automation systems. Required Basic Knowledge You require a general knowledge in the field of automation engineering to be able to understand this manua. In addition, you should know how to use computers or devices with similar functions (e.g programming devices) under Windows 2000 or Windows XP operating systems. Where is this Manual valid? This manual is valid for the product. A5E00166353-03 iii

Preface Certification have the following certification: Underwriters Laboratories, Inc.: UL 60950 registered and Canadian Standard C22.2 No. 60950 (Information Technology Equipment) CE Labeling fulfil the requirements and protection guidelines of the following EU directives: EC Directive 89/336/EWG "EMC directive" CTick Mark is compliant with requirements of the AS/NZS 3548 (Australian and New Zeeland) standard. Further Support If you have any technical questions, please get in touch with your Siemens representative or agent responsible. You will find your contact person at: http://www.siemens.com/automation/partner Training Centers Siemens offers a number of training courses to familiarize you with the SIMATIC S7 automation system. Please contact your regional training center or our central training center in D 90327 Nuremberg, Germany for details: Telephone: +49 (911) 895-3200. Internet: http://www.sitrain.com iv A5E00166353-03

Preface A&D Technical Support Worldwide, available 24 hours a day: Nuernberg Johnson City Beijing Peking Worldwide (Nuernberg) Technical Support 24 hours a day, 365 days a year Phone: +49 (180) 5050-222 Fax: +49 (180) 5050-223 E-Mail: adsupport@ siemens.com GMT: +1:00 Europe / Africa (Nuernberg) Authorization Local time: Mon.-Fri. 8:00 to 5:00 PM United States (Johnson City) Technical Support and Authorization Local time: Mon.-Fri. 8:00 to 5:00 PM Asia / Australia (Beijing) Technical Support and Authorization Local time: Mon.-Fri. 8:00 to 5:00 PM Phone: +49 (180) 5050-222 Phone: +1 (423) 262 2522 Phone: +86 10 64 75 75 75 Fax: +49 (180) 5050-223 Fax: +1 (423) 262 2289 Fax: +86 10 64 74 74 74 E-Mail: adsupport@ siemens.com E-Mail: simatic.hotline@ sea.siemens.com E-Mail: adsupport.asia@ siemens.com GMT: +1:00 GMT: -5:00 GMT: +8:00 The languages of the SIMATIC Hotlines and the authorization hotline are generally German and English. A5E00166353-03 v

Preface Service & Support on the Internet In addition to our documentation, we offer our Know-how online on the internet at: http://www.siemens.com/automation/service&support where you will find the following: The newsletter, which constantly provides you with up-to-date information on your products. The right documents via our Search function in Service & Support. A forum, where users and experts from all over the world exchange their experiences. Your local representative for Automation & Drives.. Information on field service, repairs, spare parts and more under "Services". vi A5E00166353-03

Contents 1 Properties of the...1-1 1.1 Function...1-1 1.2 Performance specifications...1-2 2 Package Components...2-1 3 Requirements for Operation...3-1 3.1 Software requirements...3-1 3.2 Hardware requirements...3-1 4 Hardware Design of the...4-1 4.1 Connections...4-1 4.2 LEDs on the...4-2 4.3 Power supply...4-3 4.4 MPI/DP interface...4-5 4.5 USB interface...4-6 5 Working with the...5-1 5.1 Technical safety notes...5-1 5.2 Installation of the software...5-1 5.3 Configuring the PG / PC interface...5-2 5.4 Connecting the...5-3 6 on the MPI/DP network...6-1 6.1 General...6-1 6.2 Use as a stand-alone system...6-1 6.3 Use in a networked system...6-2 7 Firmware Update...7-1 8 Error Diagnostics...8-1 9 Technical Data...9-1 A Index Appendix...A-1 A.1 Certificates, Directives and Declarations... A-1 A.2 Certification for the USA, Canada and Australia... A-3 A5E00166353-03 vii

Contents viii A5E00166353-03

1 Properties of the The is compatible with USB V1.1 and satisfies the requirements for "Low-Powered USB devices. The SIMATIC supports the energy saving mode (hibernate mode). 1.1 Function The SIMATIC connects a PC to the MPI/DP interface of an S7/M7/C7 system via USB. A slot is not required in the PC, which means that the adapter can also be used for non-expandable PCs such as notebooks. USB MPI/DP Fig. 1-1: Configuration with Note Only one can be used on a PC. A5E00166353-03 1-1

Properties of the 1.2 Performance specifications The can be used on MPI and PROFIBUS networks. Starting at firmware V1.1, the can also be operated on homogeneous PPI networks. The following table shows the transmission rates and network types supported by the. Table 1: Bus profile and transmission rates Transmission rate MPI PPI PROFIBUS DP Standard Universal Userdefined 9.6 kbps -!!!!! 19.2 kbps!!!!!! 45.45 kbps - -!! -! 93.75 kbps - -!!!! 187.5 kbps!!!!!! 0.5 kbps - -!!!! 1.5 kbps! -!!!! Other performance features Automatic bus profile detection Up to 16 communication connections, of those up to 4 slaves (DP/T connections) Routing support 1-2 A5E00166353-03

2 Package Components The SIMATIC package includes: One "SIMATIC Software CD containing the software and documentation One USB cable (5 m) One MPI cable (0.3 m) The MPI cable can be used to connect the to MPI, homogeneous PPI or PROFIBUS (DP) networks. Spare parts Spare parts USB cable (5 m) MPI cable (0.3 m) Order number A5E00276884 A5E00164946 You can forward your spare parts orders to your local Siemens partner. A5E00166353-03 2-1

Package Components 2-2 A5E00166353-03

3 Requirements for Operation 3.1 Software requirements One of the following operating systems must be installed on the PC in order to be able to operate the SIMATIC : Windows 2000 Windows XP Professional Windows XP Home and a SIMATIC software package that communicates via MPI (for example, STEP 7) To operate the on a PPI network, you also need the STEP 7- Micro/Win32 SW package. 3.2 Hardware requirements You require a PC with a USB interface and a CD ROM drive. A5E00166353-03 3-1

Requirements for Operation 3-2 A5E00166353-03

4 Hardware Design of the 4.1 Connections Connections on the : USB interface LEDs: USB Power MPI MPI/DP interface A5E00166353-03 4-1

Hardware Design of the 4.2 LEDs on the The LEDs on the indicate the following: Name Color Meaning USB green Lights up when the is connected to the USB and the operating system of your PC is in normal operating mode. This LED is not lit when the PC is in standby or idle mode. The LED flickers when data are being transferred. POWER green Lights up when the is supplied with the necessary power. Flashes when a hardware fault is detected. MPI green Lights up when the is connected to the MPI/DP network and is operational. The LED flashes when data are transferred on the MPI/DP network. The LED is off when no firmware has been loaded in the PC Adapter USB. The LED displays for error states are described in Chapter 8 Error Diagnostics. 4-2 A5E00166353-03

Hardware Design of the 4.3 Power supply The is supplied with power by the automation system via the MPI cable included in the delivery. It requires 24 V (see the technical data).! Caution Always connect the to power supplies with limited power or NEC Class 2. UL cable, AWM 2464, 80 C, 300 V, 28 AWG, VW-1. Fig. 1: MPI cable, 0.3 m with 9-pin sub-d connectors.! Warning Always use the MPI cable included with your. A5E00166353-03 4-3

Hardware Design of the Shield 1 2 3 4 5 6 7 8 9 NC NC NC M24V LTG_B RTSAS M5V P24V LTG_A Shield NC NC NC 1 2 3 4 5 6 7 8 9 9-pin subminiature D 9-pin subminiature D Fig. 2: MPI cable (0.3 m) 9 8 RTSPG LTG_A USB V1.1 12 MBit/s P5 D- D+ M5 1 2 3 4 USB Electronics 5V 1M NC NC 3 4 6 5 1 LTG_B RTSAS P5V M5V M 7 P24V USB POWER MPI +3,15V +1,95V M 24V DC 2 M24V Shield PC potential area AS potential area Fig. 3: Block diagram The MPI/DP and USB interfaces of the are electrically isolated within a safety extra low-voltage circuit (SELV). It can therefore be operated directly on ungrounded S7/M7/C7 systems. 4-4 A5E00166353-03

Hardware Design of the 4.4 MPI/DP interface Pin assignment Pin assignment of the MPI/DP interface: Description of signals Pin no. Short name Meaning Input / Output 1 NC Not connected 2 M24V Zero volt of the 24 V power supply, Input provided by the electronic DC/DC circuit of the adapter (AS potential range) 3 LTG_B Data line B Input / Output 4 RTS_AS RTSAS control signal for receive data Input current. The signal is active 1 when the directly connected AS is transmitting data. 5 M5V Reference potential of the MPI/DP Input interface for the RTS_AS and RTS_PG signals 6 P5V Not connected 7 P24V Zero volt of the +24 V power supply, Input provided by the electronic DC/DC circuit of the adapter (AS potential range) 8 LTG_A Data line A Input / Output 9 RTS_PG Adapter s RTS output signal. The signal is Output 1 when the adapter is transmitting data. The signal is not contained in the 0.3 m MPI cable! Shielding on connector housing* * The shielding is interconnected with the USB interface via the adapter electronic module. A5E00166353-03 4-5

Hardware Design of the 4.5 USB interface Interface pin assignments Top view of the USB socket: Description of signals Pin no. Signal 1 +5V Power supply 2 -Data - Differential signal 3 + Data + Differential signal 4 Ground Ground! Caution Operating several USB devices on your PC may effect the data transmission rates. To obtain optimum communication performance with the automation system, disconnect USB devices that are not required. 4-6 A5E00166353-03

5 Working with the 5.1 Technical safety notes Qualified personnel The device should only be accessed by qualified personnel. Qualified personnel as referred to in safety guidelines in this documentation are persons who are authorized to commission, ground, and tag circuits, equipment, and systems in accordance with established safety practice. Use as intended:! Warning The equipment/system or the system components may only be used for the applications described in the catalog or the technical description, and only in combination with the equipment, components, and devices of other manufacturers as far as this is recommended or permitted by Siemens. The product will function correctly and safely only it is transported, stored, set up, and installed as intended, and operated and maintained with care. 5.2 Installation of the software Setup runs the installation of the software automatically after you insert the CD. If the autorun function is disabled, proceed as follows: 1. Insert the CD for your into the CD-ROM drive. 2. Open the root directory of this drive. 3. Double-click "setup.exe" to run Setup. Setup is menu controlled. Please note the readme file in the root directory on the CD for information on the installation and use of your. A5E00166353-03 5-1

Working with the 5.3 Configuring the PG / PC interface You are prompted to configure the PG / PC interface during setup. 1. Check the PG / PC interface dialog box for the following interface settings. The following items should be available in the selection list: - PC Adapter (Auto) (only when STEP 7 is installed) - PC Adapter (MPI) - PC Adapter (PPI) (only if STEP 7-Micro/Win has been installed) - PC Adapter (PROFIBUS) If this is not so: - Click "Select..." to add / remove interfaces. This opens a dialog box for installing / uninstalling interfaces. - Select the PC Adapter module from the list and install it. Click "Close" to exit the dialog box. 4. Now select the interface configuration in the PG / PC interface dialog box with which you intend to communicate, for example, the PC Adapter (MPI). Click "Properties". 5. In the Properties dialog box of the PC Adapter (see table below), check if the parameter settings fit your system configuration, and change the settings if necessary: Interface configuration PC Adapter (Auto) PC Adapter (MPI) PC Adapter (PPI) PC Adapter (PROFIBUS) check in the tab Auto-detection of the bus profile MPI PPI PROFIBUS 6. The properties dialog box for the PC Adapter (MPI) appears. Select the local connection tab. Set USB in the COM port selection box (or connection to:). 7. Close this properties dialog box by clicking "OK". 8. Click OK to close the PG / PC interface dialog box. 9. A warning appears if you have changed an access path during the configuration. Acknowledge the message with OK to accept the changes. 5-2 A5E00166353-03

Working with the 5.4 Connecting the Connecting to the PC 1. Insert the supplied USB cable into the USB port of your PC. 2. Plug the other end of the USB cable into. Connecting to the PLC 1. Insert the supplied MPI cable into the and screw-tighten it. 2. Insert the other end of the MPI cable into the MPI port of your CPU and screwtighten it. Note The adapter and the S7/M7/C7 system each represent a network node. In networks consisting of two nodes (adapter and S7/M7/C7 system), the adapter is connected directly to the socket of the S7/M7/C7 system. When the network contains more than two nodes, the adapter should be connected to the "PG socket of a PROFIBUS connector (SINEC L2 bus connector). You do not need to change the settings of the terminating resistors. Caution Do not connect the SIMATIC to the automation system with any other cable than the supplied MPI cable. A5E00166353-03 5-3

Working with the 5-4 A5E00166353-03

6 on the MPI/DP Network 6.1 General A maximum of 32 nodes can be connected to an MPI/DP network segment. The total cable length may not exceed 50 meters. Several network segments can be connected together using RS485 repeaters, thus allowing a maximum number of 127 network nodes. The maximum data transmission rate in the MPI/DP network is 12 Mbps. The supports transmission rates up to 1.5 Mbps.! Warning An extension cord should not be interconnected between the adapter and the S7/M7/C7 system. 6.2 Use as a stand-alone system The following illustration shows the connection to a stand-alone system (2 network nodes). A5E00166353-03 6-1

on the MPI/DP Network 6.3 Use in a networked system The following illustration shows the connection in a networked S7 system (MPI/DP network containing 2 or more network nodes). S7x S7y 3) Adapter PROFIBUS bus cable 3) Bus connector with PG socket 4) PROFIBUS bus connector 4) Once you have completed the installation and configuration of the PG / PC interface, you can communicate with the PLC using your SIMATIC software package. 6-2 A5E00166353-03

7 Firmware Update The firmware of the can be updated, for example, when new functions have been added. How to update the firmware: Download the latest firmware and the firmware update utility from the Internet: http://www.siemens.de/automation/simatic-cs Search the product support area for the term ". Download the self-extracting EXE file containing the available firmware and the firmware update utility to your PC. Unzip the files to a local drive, then run the *.exe file to update your PC Adapter USB firmware. Follow the instructions on the screen. Please read the readme file in the "Firmware" folder of the firmware update utility. It contains notes about the installation and use of the latest firmware. Note The latest firmware and the firmware update utility is available on your "SIMATIC Software " CD in the "Firmware" folder at the time of delivery. A5E00166353-03 7-1

Firmware Update 7-2 A5E00166353-03

8 Error Diagnostics The information in the following section offers support to help you locate and perhaps correct common errors by yourself. Error / cause The power LED is not lit MPI cable not connected The PLC is switched off Hardware error The USB LED is not lit USB cable not connected PC and are in energy saving mode (hibernate mode). The PC can not find the To avoid or correct errors Connect the MPI cable Switch on the PLC Inform Customer Support Connect the USB cable permitted operating mode Check your driver installation, and install it if necessary The MPI LED is not lit The MPI cable not connected Connect MPI cable Firmware not loaded Start the supplied firmware update utility and check if the firmware is loaded. None of the LEDs is lit MPI cable not connected Connect the MPI cable The required 24 V DC are not wired to the MPI socket Check the wiring Hardware error Inform Customer Support The power LED flashes continuously Hardware error If the POWER LED of the device continues to flash continuously even after pulling and plugging the MPI cable several times, the device is defective and should be replaced. A5E00166353-03 8-1

Error Diagnostics 8-2 A5E00166353-03

9 Technical Data Order no. 6ES7972-0CB20-0XA0 Dimensions Approx. 105 x 58 x 26 mm Weight Approx. 250 g Interfaces to S7 / M7 / C7 RS485 (max. 1.5 Mbps) to PC USB (12 Mbps) Power supply 24 V DC (SELV) (18V.. 30 V DC) (via MPI interface) Power consumption 50 ma (typically) / 100 ma (max.) Inrush current Imax. 700 ma; 8µs Safety Safety class Safety class III conforming to IEC 60950 Safety requirements IEC 60950 corresponds to DIN/EN 60950 Degree of protection IP 20 Electromagnetic compatibility (EMC Noise emission Limit value class B according to EN 55022 Noise immunity on signal lines 2 kv (according to IEC 61000-4-4; burst; length > 3m) Immunity to discharge of static electricity 6 kv, contact discharge (according to IEC 61000-4-2 (ESD) 8 kv, air gap discharge (according to IEC 61000-4-2 RF immunity 10 V/m 80-1000 MHz, 80% AM (to IEC 61000-4-3) 10 V/m 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3) RF conductance 10 V 9 khz - 80 MHz (to IEC 61000-4-6) Climatic conditions Temperature Operation Storage / shipping Tested according to DIN EN 60068-2-2, DIN IEC 60068-2-1 +0 C to +60 C, temperature change max. 10 K/h 20 C to +60 C, temperature change max. 20 K/h Relative humidity Tested according to DIN IEC 60068-2-3, DIN IEC 60068-2-30, DIN IEC 60068-2-14 Operation Storage / shipping 5% to 80% at 25 C (no dewing) 5% to 95% at 25 C (no dewing) A5E00166353-03 9-1

Technical Data Mechanical ambient conditions Vibration Operation Storage / shipping Shockproof Operation Storage / shipping Tested according to DIN IEC 60068-2-6 10 to 58 Hz: amplitude 0.075 mm, 58 to 500 Hz: acceleration 9.8 m/s 5 to 9 Hz: amplitude 3.5 mm, 9 to 500 Hz: acceleration 9.8 m/s Tested according to DIN IEC 60068-2-27/29 150 m/s, 11 ms, 100 shocks 250 m/s, 6 ms, 1000 shocks 9-2 A5E00166353-03

A Appendix A.1 Certificates, Directives and Declarations Notes on the CE Label The following applies to the SIMATIC product described in this documentation: EMC directive This product fulfills the requirements for the EC directive 89/336/EEC on electromagnetic compatibility and the following fields of application apply according to this CE label: Fields of application Residential and commercial areas and small businesses. Requirement for Noise emission Noise Immunity EN 61000-6-3: 2001 EN 61000-6-1: 2001 Industry EN 61000-6-4: 2001 EN 61000-6-2: 2001 Declaration of Conformity The EC declarations of conformity and the documentation relating to this are available to the authorities concerned, according to the above EC directive, from: Siemens AG Automation and Drives A&D AS RD 4 PO Box 1963 D 92209 Amberg, Germany Phone: +49 9621 80 3283 Fax: +49 9621 80 3278 Observing the installation guidelines The installation guidelines and notes on safety given in the manual must be observed at startup and during operation. A5E00166353-03 A-1

Appendix Connecting I/O devices Noise immunity when connected to industrial standard PC conforms with the requirements of EN 61000-6-2:2001. A-2 A5E00166353-03

Appendix A.2 Certification for the USA, Canada and Australia One of the following markings on a device is indicative of the corresponding approval: Underwriters Laboratories (UL) according to the UL 60950 standard, and Canadian standard C22.2 No. 60950 (I.T.E) or to UL508 and C22.2 No. 142 (IND.CONT.EQ) UL Recognition Mark EMC Australia and New Zealand This product meets the requirements of the AS/NZS 3548 Standard. A5E00166353-03 A-3

Appendix A-4 A5E00166353-03

Index B Bus profile... 1-2 C Compatibility... 1-1 Configuration with the... 1-1 Connecting to the PC... 5-3 Connecting to the PLC... 5-3 Connections... 4-1 D Description of signals... 4-5 E Energy saving mode... 1-1 Error diagnostics... 8-1 F Firmware update... 7-1 H Hardware requirements... 3-1 M MPI... 4-2 MPI cable...2-1 MPI/DP interface...4-5 MPI/DP network...6-1 O Operating state LEDs...4-2 P Package components...2-1 Performance specifications...1-2 POWER...4-2 Power supply...4-3 S Software installation...5-1 Software requirements...3-1 T Technical data...9-1 Technical safety notes...5-1 Transmission rate...1-2, 6-1 U USB...4-2 USB cable...2-1 USB interface...4-6 A5E00166353-03 Index-1

Index Index-2 A5E00166353-03