ALUMINIUM. Product Data Sheet

Similar documents
Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Longspan. Insulated Panels. Architectural Frame to Frame Insulated Panel System. CI/SfB (4-) Rh2 September 2008

I-Line - Snap-On Feature

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Colonnade Security Pipe

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Composite Panel Firewall Systems

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Rockwool Cladding Roll

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Kingspan Roof Tile. Insulated Panels. Insulated Tile Effect Roofing System. Building to the Power of. CI/SfB. September 2008

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Installation Detailed installation instructions are provided which should be strictly followed.

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Kingspan Envirodek Structural Green Roof System

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

SECTION STANDING SEAM METAL ROOF

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

RPV - RP - RA air handling units

KALZIP STANDING SEAM ROOF SYSTEMS KALZIP DECK ROOF SYSTEM

Steel-framed Walls. Insulation

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Series 602 MAGNUM Sliding Window DESIGNER SERIES

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

The Kingspan Insulation Price List 1 st January 2013

ABSeam Panel Overview and Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions

Architectural composite panels

Pilkington Reflite Handling and Processing Guidelines Solar Control

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Preformed Metal Roofing and Siding

Fire Resistant Systems

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

CLEAR-DIVISIONS CENTERFOLD

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Window Installation Instructions

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Upstand Rooflight Natural Light Translucent Upstand Systems

Residential Roofing Guide

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Manual lifting and handling

PART 1 GENERAL 1.1 SECTION INCLUDES

Asphalt Shingle Application Requirements

BETONYP building boards. The modern way of living.

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Hanson Building Products. precast basement solutions

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

WATERPROOFING FOR CONCRETE STRUCTURES

Installation Window Building In Details

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Product Data Sheet ROCKPANEL Rockclad

Mezzanine. Technical manual

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

VERTICAL LOCK Table of Contents

Packaged Terminal Air Conditioner Wall Sleeve Installation

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

Energy Company Obligation (ECO): Technical Monitoring Questions

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

Façade panels for interior cladding on a wooden supporting structure

Lindab Seamline Application guide. Lindab Seamline TM. Lindab Standing Seam Roofing Application guide

Rooflight INSTALLATION INSTRUCTIONS

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

FIRE RATED GLAZING System Guide

WATERPROOFING OF WET ROOMS

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Roof Curbs, Extensions and Equipment Supports

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

metal Duil~ing manufacturers Association

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

GUIDELINE SPECIFICATIONS

CLEAR-DIVISIONS VARIOFOLD


Rockwool Flexi Insulation Application Guide

Series 456 Commercial Awning Window

Concepts. Products. Service. Lindner Plus Organisation

Confort 26. Sliding Systems. Sapa Building System

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

M E TA L C O N TA I N E R S 90

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Aluminium foil properties: Applications of aluminium foils and thin gauge strips in thickness below 0,50 mm:

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Transcription:

ALUMINIUM Benchmark Aluminium system is available in five different cassette options and installed on a specifically designed Benchmark. Images above courtesy of Euramax FAÇADE DATA Materials Benchmark Aluminium façade system, which is available in five different cassette options is installed on a specifically designed Benchmark. Aluminium is a high quality alloy 1050H14 available in an anodized finish, pre-painted aluminium sheets, post painted aluminium sheets and post powder coated. The aluminium can be produced in virtually any colour BS, NCS and RAL or be matched to other colours on request. CASSETTE DATA Profile Options Benchmark HOC System Recessed Fix Cassette Thickness: Cassette Thickness: 2.0mm, 3.0mm 2.0mm, 3.0mm Product Tolerances Length 2mm +2mm Width 2mm +2mm Thickness 2mm +2mm Squareness 2mm +2mm Environmental Benchmark Aluminium can be fully recycled and used for the production of new material. Fire Benchmark aluminium has Class 1 surface spread of flame to BS 476-7:1987, and are Class 0, as defined by building regulations. Tray Cassette Thickness: 3.0mm Interlocking Plank Available: 1.5mm, 2.0mm Shingle Cassette Thickness: 0.9mm* *Polyester Powder Coated Please Note: Maximum visible face dimensions for each cassette are subject to wind loadings. Please contact Benchmark Technical Services for maximum dimensions available relevant to each cassette option. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) 1352 716100 info@kingspanbenchmark.com Page 1 Greenfield, Holywell CH8 7GJ, UK Fax: +44 (0) 1352 710161 www.kingspanbenchmark.com (Edition 7- Oct 2011)

KARRIER PANEL DATA Insulation Core Polyisocyanurate (PIR): EcoSafe with zero Ozone Depletion Potential (zero ODP). Product Tolerances Length 2mm +2mm Width 2mm +2mm Thickness 2mm +2mm End Squareness 3mm +3mm Flatness (per metre) 2mm +2mm Available Lengths Standard length is 1.8 to 12 metres. Panel lengths up to 17 metres are available. Panels less than 1.8 metres long can be supplied and are subject to an extra charge. These panels cannot be end lapped. Materials Steel Substrate S220GD+ZA hot-dip zinc/aluminium Galfan coated metal to BS EN10214: 1992. Standard external sheet thickness 0.63mm, standard internal sheet thickness 0.4mm. Coatings - External Sheet Kingspan XL Forté TM. Colour is Merlin Grey. Reverse side of sheet coated with a light grey polyester coating. Coatings - Internal Liner Factory Applied Side Joint Seal All side joints have a factory-applied seal fitted into the groove to automatically seal the joint between panels. Fire The steel outer and inner facings of the have a Class 1 surface spread of flame to BS476-7: 1987, and are Class 0, as defined by Building Regulations. Biological Benchmark insulated panels are normally immune to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the construction, and the panels are not considered deleterious. Standard polyester coating developed for use for the internal lining of insulated panels. Standard colour is bright white with an easily cleaned surface. Foodsafe hygienic coating developed for use where the liner is exposed to foodstuffs and is regularly cleaned. Colour white. Kingspan XL Forté TM coating for internal high humidity environments. Colour white. Reverse side of sheet coated with a light grey polyester coating. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) 1352 716100 info@kingspanbenchmark.com Page 2

SYSTEM WEIGHT Benchmark Aluminium façade system has an overall typical weight depending upon thickness: Shingle Option: 0.9mm gauge Weight (Kg/m²)* 14.9 15.3 15.7 16.5 17.3 18.0 18.5 Interlocking Plank: 2.0mm gauge** Weight (Kg/m²)* 19.9 20.3 20.7 21.5 22.3 23.0 23.5 Benchmark HOC System: 3.0mm gauge** Weight (Kg/m²)* 24.6 25.0 25.4 26.4 27.0 27.7 28.2 Recessed Fix: 3.0mm gauge** Weight (Kg/m²)* 22.6 23.0 23.4 24.4 25.0 25.7 26.2 Tray: 2.0mm gauge Weight (Kg/m²)* 19.9 20.3 20.7 21.5 22.3 23.0 23.5 *Based on complete system - cassette, attachment and panel weight inclusive. ** Please note the weights above are the maximum gauge thickness available for each cassette option as stated. A decrease in material gauge will reduce the overall typical weights. Please contact Benchmark Technical Services should further information be required. SYSTEM ATTACHMENT Benchmark HOC System A vertical mullion is attached to the face of the Karrier Panel at the required centres, secured using KSAFL6 fasteners. Adjustable clips (pre-assembled with rubber isolators attached) are installed onto the mullions and can slide up and down and once situated in the correct location are held in place using Hexagonal Headed M8 stainless steel set screws. The cassettes are located onto the clips using prefabricated hooks. Once in place, stainless steel selfdrilling screws are installed through the top flange of cassette to attach cassette to the vertical mullion to prevent movement in service. Tray Cassette Option Extruded aluminium track to BS1474 in 6063/T6 grade alloy is bonded to the tray cassette. Folded top edge of cassette secured to aluminium secondary rail system using self-drilling / self-tapping stainless steel coated screws. Extruded aluminium secondary rail system to BS1474 in 6063/T6 grade alloy. Coated black. Recessed Fix Option The Aluminium cassette is attached directly to the Karrier panel with rivets. Shingle The shingle cassettes interlock with one another. Stainless steel shingle clips hook on to the shingle cassette and are then riveted to the face of the Benchmark. Sealant tape is used to isolate the clip from the face of the Karrier panel and minimise rattle. Interlocking Plank Interlocking Plank Cassettes are fixed directly back to the Benchmark Karrier panel with rivets. Sealant tape is used to isolate the cassette from the face of the. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) 1352 716100 info@kingspanbenchmark.com Page 3

SYSTEM PERFORMANCE Thermal Insulation Thermal Transmittance (U value) calculated in compliance with Building Regulations Approved Documents L2A & L2B (England & Wales), Technical Handbooks Non-Domestic Sections 6 (Scotland), Part F2 (Northern Ireland) and Part L (Republic of Ireland - based on the Overall Heat Loss Method). Thickness (mm) U-value (W/m²K) 0.35 0.30 0.26 0.21 0.17 0.15 0.14 PLEASE NOTE: For England and Wales; 0.26 W/m²K is the U-Value used for Notional Building Wall. This U-Value or better is recommended for compliance and can be seen as underlined in the above table. For Scotland; 0.27 W/m²K is the U-Value used for Notional Building Wall. This U-Value or better is recommended for compliance and can be seen as highlighted in bold in the above table. Acoustics Benchmark Aluminium façade system has a single figure weighted sound reduction Rw = 24dB. Sound Reduction Index (SRI) Frequency (Hz) 63 125 250 500 1k 2k 4k 8k SRI (db) 20 15 17 23 18 25 40 46 Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) 1352 716100 info@kingspanbenchmark.com Page 4

STRUCTURAL LOAD/SPAN TABLE FOR KARRIER PANEL (To be checked against unfactored design wind-loads) Notes: 1. Values have been calculated using the limit state method in the European Recommendations for the Design of Sandwich Panels (ECCS document No.115 2001), taking imposed loads, temperature and creep into account. 2. For each value individual and combined load cases with appropriate load factors and temperatures have been considered. These are detailed under Structural Performance in Building Design Section. 3. The table is for dark coloured panels. 4. The following deflection limits have been used: Pressure Loading L/100 Suction Loading L/100 5. For intermediate values linear interpolation may be used. 6. The actual wind suction load resisted by the panel is dependent upon the number of fasteners used and material of the rail. The fastener calculation should be carried out in accordance with the appropriate standard. For further advice please contact Benchmark Envirocare Technical Services. 7. The allowable tolerance between bearing planes of adjacent supports is L/600, where L is the distance between supports. 8. Load span tables for spans outside of those shown are available from the Benchmark Technical Services department. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) 1352 716100 info@kingspanbenchmark.com Page 5

PACKING AND STORAGE Aluminium Cassettes The cassettes are packed on a pallet with cardboard on top. Cardboard is also placed between each set of cassettes. A completed pack is wrapped in cardboard and wood is fixed around the top and sides. Packaging is completed by shrink wrapping the entire pallet in polythene. Protect Benchmark aluminium pallets during storage against rain, penetration of moisture and condensation. Avoid any condensation forming (e.g. when transporting cold cassettes to warmer rooms). Only pallets of identical size should be stacked. Store the pallets stacked one over the other (do not store panels standing vertically), with a maximum of 2 pallets of the same format stacked on top of each other (heavy pallets at the bottom).storage exceeding 6 months should be avoided, as it may become difficult to remove the protective foil. When stacking the cassettes nothing should be placed in-between them, as this could produce marks on the panels. The Benchmark s are stacked horizontally. Removable hot melt adhesive is laid between each panel. The top, bottom, sides and ends are protected with polystyrene and timber packing and the entire pack is wrapped in polythene. To ensure panels remain in prime condition while stored onsite, the panels need to be stored in a safe, clean and trade free area. Personnel should not walk over packs. Store the panels on a slight slope ensuring any penetrating rainwater drains off and ensure regular inspection the panel packs. Should panel s need to be stored for a period of time in excess of 3 months, please contact Benchmark Technical Services. The number of panels in each pack depends on panel length and weight. Typical pack height is 1100mm (based on 100mm thick panel). Panels per pack Sea Freight Fully timber crated packs are available on projects requiring delivery by sea freight shipping, at additional cost. Alternatively, steel containers can be used. Special loading charges apply. HANDLING The pallets must be handled carefully during transport and unloading. Do not handle open pallets. Upon delivery the pallets must be examined for any damage due to moisture (panels that have become wet must be dried to avoid any spots or corrosion forming). Individual cassettes must be lifted off the pallet by two people holding all four corners and not drawn over each other. Carry the cassettes vertically. Wear gloves to avoid staining. To avoid possible reflection differences, it is recommended to install the panels in the same direction as marked on the protective peel-off-foil. Please note that should the protective foil partially come off during processing, dirtied edges can occur in the course of time. SITE INSTALLATION PROCEDURE Site assembly instructions are available from the Kingspan Benchmark Field Service Department. QUALITY & DURABILITY 18 14 12 11 9 7 7 Benchmark components are manufactured from the highest quality materials to rigorous quality control standards, complying with ISO 9001:2000 standard, ensuring long-term reliability and service life. Maximum pack weight 1500kg. Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) 1352 716100 info@kingspanbenchmark.com Page 6

GUARANTEES & WARRANTIES Benchmark will provide external coating and product guarantees on an individual project basis. DELIVERY AND OFF- LOADING Transportation of Benchmark packs to site is by road transport (unless indicated otherwise). It is the customer s responsibility to check the site for restrictions (i.e. entrance to site, power lines etc.) and agree a storage area to be used, also to identify the correct type/methods of off-loading/hoisting facilities to be used i.e. crane, crane forks, lifting beam/ slings and airbags, forklift or specialist lifting equipment. Always check the current certification of the crane, crane forks, lifting beam, slings, forklift, or specialist lifting equipment prior to carrying out offloading/hoisting operation (i.e. with correct current SWL Certification). Greenfield Business Park No 2 Flintshire, North Wales Tel: +44 (0) 1352 716100 info@kingspanbenchmark.com Page 7