Hazardous Area DC Audible and Visual Alarms

Similar documents
Flameproof Audible Signal 115 db (A) Series YA90

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Series 8146/5-V37 and Series 8150/5-V37

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Engineering Specifications XNX Universal Transmitter

Inductive sensor NI10-M18-Y1X-H1141

Hazardous Area. Industrial & Process Control. Fire & General Signalling

Honeywell Analytics Lines of Business

Sieger Searchpoint Optima Plus

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Triple Waveband Infra-Red Flame Detection

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

SEISMIC VELOCITY TRANSDUCER T1-40

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Compact pressure switch Flameproof enclosure Ex d Model PCA

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Terminal Boxes Series 8146

Terminal Box. Specifications TNCN

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Instructions for Safe Use

3DLevelScanner II TECHNICAL DATA SHEET

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

Floodlight Range Installation Guide

CompactLogix Power Supplies Specifications

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Touchpoint Pro. Flexible Gas Control System

Technical data sheet TDS0070

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Lockout Specification BW Clip Maintenance-free single gas detector

Technical Information RIA14

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

FGM 160 ATEX EC type examination certificate

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

Power Supplies 3. SDN-P DIN Rail Series

Linear Luminaire with LED Series EXLUX 6402/2

EX 2000/EX 2000 C/ GD 2000/GDP

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Rosemount 752 FOUNDATION fieldbus Remote Indicator

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

S-series Mass Connection Solutions

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Plug and Socket Devices CES 63 A Series 8579

Safety instructions VEGADIS DIS81.CEIA/V****

Design of intrinsically safe systems

S-series DC to DC Power Supply

Micro Motion 3098 Gas Specific Gravity Meter

Application Requirement

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

CB Zone Conventional Control Panel

How To Use An Irius Pid Detector

Plastic tube flowmeters Series PT/PS

Flame detection across the spectrum. Range Brochure

Technical Data. Dimensions

Fluke Digital Multimeters Solutions for every need

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Explosion proof enclosures

Plug and Socket Devices SolConeX 16 A Series 8570

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Technical Specifications

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Analogue addressable devices

Rosemount 751 Field Signal Indicator

Preset Counter signo 721

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Inductive slot sensor

Operating Instructions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Cross-beam scanning system to detect slim objects. 100 mm in

ALARMLINE ANALOGUE Linear Heat Detection System

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

How To Use A Ds340 (Dsp)

WD-AMX Water Detection Controllers

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Premier M Plus & Infinity 8

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

distributing & controlling system solutions

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Telephone- and leased line modem for industrial applications TD-36

3500/40M Proximitor* Monitor

Transcription:

DC Audible and Visual Alarms A Range of 24Vdc operated ATEX approved Ex d & I.S. audible and visual alarms available for use in a wide range of indoor or outdoor hazardous area applications

DC Audible and Visual Alarms A Range of 24Vdc operated, ATEX approved Ex d and I.S. audible and visual alarms, available for use in a wide range of indoor or outdoor hazardous area applications. When combined with the Honeywell range of fixed point gas monitoring equipment, the systems can provide clear warning to operators that flammable or toxic gas hazards are in the area. Ex d Audible Alarms Features Maximum output: 117dB(A) @ 1 metre Nominal output: 110dB(A) @ 1m / 3dB Tone 2 ATEX II 2G Ex d IIC T4 (Tamb. 50 to 55 C) ATEX / CENELEC / FTZU / IECEx / GOST R 32 alarm tones (UKOOA / PFEER compliant) 3 stage alarm Volume control Automatic synchronisation on multisounder systems 100m effective range @ 1kHz Voltage: 24vdc /25%, 250mA Negative or positive remote switching Ingress Protection: IP67 Enclosure material: Marine grade LM6 Aluminium Chromated & powder coated finish good resistance to humidity and salt spray environments Horn Material: High impact UL94 V0 & 5VA FR ABS Operating temperature: 50 to 55 C Storage temperature: 50 to 70 C Large range of certified end of line resistors. Weight: 3.20kg KEMA Certificate number: 99ATEX6312 Very large termination area Dual M20 ISO cable gland entries (supplied with one stopping plug) Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions In and out terminals Terminals accept 0.5 to 4.0mm² cables Line monitoring: Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor, or diode within Exd enclosure (dc versions) Flameproof sounders which are certified to the European Standards EN 50014:1992 and EN 50018:1994 and meet the requirements of ATEX directive 94/9/EC. The sounders produce loud warning signals and can be used in hazardous areas where potentially flammable atmospheres may be present. Thirty two different first stage alarm sounds can be selected and each one can be externally changed to a second or third stage alarm sound (see tone table below). The unit produces output levels in the 117dB(A) range. Suitable for use in Zone 1 and Zone 2 areas with gases in groups IIA, IIB and temperature classifications of T1, T2, T3 and T4. Configuration Stage 1 Frequency Description Max db @ 1m Stage 2 Stage 3 Tone 1 1000Hz continuous PFEER toxic gas 110dB(A)@1m Tone 31 Tone 11 Tone 2 800/1000Hz @ 0.25 sec alternating 110dB(A)@1m Tone 17 Tone 5 Tone 3 500/1200Hz @ 0.3 Hz 0.5 sec slow whoop 110.5dB(A)@1m Tone 2 Tone 5 Tone 4 800/1000Hz @ 1Hz sweeping 110dB(A)@1m Tone 6 Tone 5 Tone 5 2400Hz continuous 109dB(A)@1m Tone 3 Tone 27 Tone 6 2400/2900Hz @ 7Hz sweeping 109dB(A)@1m Tone 7 Tone 5 Tone 7 2400/2900Hz @ 1Hz sweeping 110dB(A)@1m Tone 10 Tone 5 Tone 8 500/1200/500Hz @ 0.3Hz sweeping 110.5dB(A)@1m Tone 2 Tone 5 Tone 9 1200/500Hz @ 1Hz DIN/PFEER P.T.A.P 110.5dB(A)@1m Tone 15 Tone 2 Continued on page 2

Ex d Audible Alarms Configuration continued Dimensions Tone 10 2400/2900Hz @ 2Hz alternating 109dB(A)@1m Tone 7 Tone 5 Tone 11 1000Hz @ 0.5Hz intermittent 110.5dB(A)@1m Tone 31 Tone 1 Tone 12 800/1000Hz @ 0.875Hz alternating 110dB(A)@1m Tone 4 Tone 5 Tone 13 2400Hz @ 1Hz intermittent 109dB(A)@1m Tone 15 Tone 5 Tone 14 800Hz 0.25 sec on, 1 sec off intermittent 103dB(A)@1m Tone 4 Tone 5 Ø181.00 Tone 15 800Hz continuous 103dB(A)@1m Tone 2 Tone 5 Tone 16 660Hz 150mS on, 150mS off intermittent 104dB(A)@1m Tone 18 Tone 5 Tone 17 544Hz (100mS) / 440Hz (400mS) NF S 32001 107dB(A)@1m Tone 2 Tone 27 262.60 Tone 18 660Hz 1.8 sec on, 1.8 sec off intermittent 105dB(A)@1m Tone 2 Tone 5 Tone 19 1.4KHz 1.6KHz 1s, 1.6KHz 1.4KHz 0.5s NFC48265 117dB(A)@1m Tone 2 Tone 5 Tone 20 660Hz continuous 104dB(A)@1m Tone 2 Tone 5 Tone 21 554Hz / 440Hz @ 1Hz alternating 107dB(A)@1m Tone 2 Tone 5 Tone 22 544Hz @ 0.875 sec. intermittent 107dB(A)@1m Tone 2 Tone 5 Tone 23 800Hz @ 2Hz intermittent 103dB(A)@1m Tone 6 Tone 5 145.00 Tone 24 800 / 1000Hz @ 50Hz sweeping 107dB(A)@1m Tone 29 Tone 5 Tone 25 2400 / 2900Hz @ 50Hz sweeping 109dB(A)@1m Tone 29 Tone 5 Tone 26 Bell 117dB(A)@1m Tone 2 Tone 1 162.63 Tone 27 554Hz continuous 107dB(A)@1m Tone 26 Tone 5 Tone 28 440Hz continuous 104dB(A)@1m Tone 2 Tone 5 Tone 29 800 / 1000Hz @ 7Hz sweeping 106dB(A)@1m Tone 7 Tone 5 Tone 30 420Hz @ 0.625 sec intermittent Austrailian alert 104dB(A)@1m Tone 32 Tone 5 Tone 31 1200 / 500Hz @ 1Hz DIN / PFEER P.T.A.P 110.5dB(A)@1m Tone 11 Tone 1 Tone 32 500 1200Hz 3.75 sec / 0.25 sec Austrailian evac. 110.5dB(A)@1m Tone 26 Tone 1 Sound levels for guidance purposes only (typically /3dB) at nominal voltage. Wiring S2 S3 S2 S3 S2 S3 S2 S3

Ex d Visual Alarms Ex d Visual Alarms Features 5 Joule Xenon: 1Hz (60 FPM) (5 Ws) ATEX II 2GD Ex d IIC T5 T100 C ATEX II 2GD Ex d IIC T6 T85 C ATEX / CENELEC / FTZU / IECEx / GOST R Suitable for Zone 1, 2, 21 and 22 gas groups IIC IIB and IIA Voltage and current: 24vdc, 300mA Red or amber lens colours available Automatic synchronisation on multibeacon systems s can be set to flipflop alternating mode with other units on multibeacon systems Tube life: emissions reduced to 70% after 8 million flashes Xenon tubes mechanically secured against shock/ vibration Ingress Protection: IP67 Enclosure material: Marine grade LM6 Aluminium Chromated & powder coated finish good resistance to humidity and salt spray environments Glass lens and Stainless Steel guard Colour available: Red (RAL3000) Operating temperature: 50 to 55 C (Exd IIC T5) 50 to 40 C (Exd IIC T6) Storage temperature: 50 to 70 C Large range of certified end of line resistors Weight: 2.45kg KEMA Certificate number: 00ATEX2006 X Flameproof beacons which are certified to the European Standards EN 50014:1992 and EN 50018:1994 and meet the requirements of ATEX directive 94/9/EC. The beacons produce synchronized visual warning signals and can be used in hazardous areas where potentially flammable atmospheres may be present. The beacons have an output of 5 joules and are suitable for use in Zone 1 and Zone 2 areas with gases in groups IIA, IIB and temperature classifications of T1, T2, T3 and T4. The unit can be used in Zone 21 and Zone 22 areas for combustible dusts and has an IP rating of IP67 and a surface temperature rating of T100 C or T85 C if the upper ambient temperature is restricted to 40 C. Synchronised Mode Dimensions 246.00 Flip Flop (alternating) Mode 145.00 153.60

Combined Ex d Audible and Visual Alarms Combined Ex d Audible and Visual Alarms Features ATEX Zones 1 and 2, II 2G Ex d IIB T4 ATEX / CENELEC / FTZU / IECEx / GOST R Voltage 24vdc, power 250mA (sounder), 270mA (beacon) Ingress Protection IP67 Enclosure material: Marine grade LM6 Aluminium Chromated & powder coated finish good resistance to humidity and salt spray environments Horn: High impact UL94 V0 & 5VA FR ABS Operating temperature: 50 to 55 C Storage temperature: 50 to 70 C Large range of certified end of line resistors Weight: DC:4.80kg KEMA Certificate number: 01ATEX2223 Very large termination area Dual M20 ISO cable gland entries (supplied with one stopping plug) Ratchet adjustable stainless steel U bracket for positive adjustment under harsh conditions In and out terminals Terminals accept 0.5 to 4.0mm² cables. Line monitoring: Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor, or diode within Exd enclosure (dc versions) Maximum output: 117dB(A) @ 1 metre Nominal output: 110dB(A) @ 1m / 3dB Tone 2 32 alarm tones (UKOOA / PFEER compliant) 3 stage alarm Volume control Automatic synchronisation on multisounder systems 100m effective range @ 1kHz Negative or positive remote switching 5 Joule Xenon: 1Hz (60 FPM) (5 Ws) Red and amber lens colours available Automatic synchronisation on multibeacon systems s can be set to flipflop alternating mode with other units on multibeacon systems Tube life: emissions reduced to 70% after 8 million flashes Xenon tubes mechanically secured against shock/ vibration Flameproof combined sounder/beacon which is certified to the European Standards EN 50014:1992 and EN 50018:1994 and meets the requirements of ATEX directive 94/9/EC. The sounder section produces loud warning signals and the beacon section produces a synchronized visual warning signal. The unit can be used in hazardous areas where potentially flammable atmospheres may be present. Thirty two different first stage alarm sounds can be selected, and each one can be externally changed to a second or third stage alarm sound (see tone table). The sounder produces output levels in the 117dB(A) range and the beacon produces an output level of 5 joules. Suitable for use in Zone 1 and Zone 2 areas with gases in groups IIA, IIB and temperature classifications of T1, T2, T3 and T4. Combinations of the above audible and visual alarms are available. Wiring Dimensions and beacon can be operated from a single supply for simultaneous operation, or from separate supplies for independent operation. Unit No. 1 Unit No. 2 Unit No. 3 S2 S3 S2 S3 S2 S3 368.00 S2 S3 and sounder wired for independent operation. Unit No. 1 Unit No. 2 Unit No. 3 Ø181.00 165.00 S2 S3 S2 S3 S2 S3 S2 S3 and sounder wired for simultaneous operation.

Ex ia Audible Alarms Ex ia Audible Alarms Features II 1G Ex ia IIC T4 (40 C<=Ta<=60 C) Rated for Zone 0,1 & 2, gas group IIC ABS flame retardent UL94V0 & 5VA housings Colour: Red RAL3000 Ingress Protection: IP65 Terminals accept 0.5 to 2.5mm² cables. Operating temperature: 40 to 60 C Storage temperature: 40 to 70 C Relative humidity: 90% at 50 C Installation: May be powered from any certified Zener barrier whose output parameters do not exceed: Uo : 28VDC Io : 93mA Po : 660mW or from any galvanic isolator specified by the system certificates 2 x M20 knockouts Output: 100dB(A) @ 1metre 49 alarm tone configurations (PFEER/UKOOA compliant) 3 stage alarm Auto synchronised sound output Effective range at 1 khz : 40m Voltage: 1628vdc via Zener barrier or galvanic isolator End of line resistor certified Input overload and reverse current protection Current: 25mA typical when powered from 24v supply via 28v 300Ohm Zener barrier An ATEX certified intrinsically safe sounder which produces a loud warning signal in a hazardous area. Fortynine first stage alarm sounds can be selected by internal switches and each one can be externally changed to a second or third stage alarm sound. The sounder may be used in all gas groups IIA IIB and IIC. Configuration Stage 1 Frequency Description Stage 2 Stage 3 Tone 1 340Hz continuous Tone 2 Tone 5 Tone 2 800/1000Hz @ 0.25 sec alternating Tone 17 Tone 5 Tone 3 500/1200Hz @ 0.3 Hz 0.5 sec slow whoop Tone 2 Tone 5 Tone 4 800/1000Hz @ 1Hz sweeping Tone 6 Tone 5 Tone 5 2400Hz continuous Tone 3 Tone 20 Tone 6 2400/2900Hz @ 7Hz sweeping Tone 7 Tone 5 Tone 7 2400/2900Hz @ 1Hz sweeping Tone 10 Tone 5 Tone 8 500/1200/500Hz @ 0.3Hz sweeping Tone 2 Tone 5 Tone 9 1200/500Hz @ 1Hz DIN/PFEER P.T.A.P Tone 15 Tone 2 Tone 10 2400/2900Hz @ 2Hz alternating Tone 7 Tone 5 Tone 11 1000Hz @ 1Hz intermittent Tone 2 Tone 5 Tone 12 800/1000Hz @ 0.875Hz alternating Tone 4 Tone 5 Tone 13 2400Hz @ 1Hz intermittent Tone 15 Tone 5 Tone 14 800Hz 0.25 sec on, 1 sec off intermittent Tone 4 Tone 5 Tone 15 800Hz continuous Tone 2 Tone 5 Tone 16 660Hz 150mS on, 150mS off intermittent Tone 18 Tone 5 Tone 17 544Hz (100mS) / 440Hz (400mS) NF S 32001 Tone 2 Tone 27 Tone 18 660Hz 1.8 sec on, 1.8 sec off intermittent Tone 2 Tone 5 Tone 19 1.4KHz 1.6KHz 1s, 1.6KHz 1.4KHz 0.5s NFC48265 Tone 2 Tone 5 Tone 20 660Hz continuous Tone 2 Tone 5 Tone 21 554Hz / 440Hz @ 1Hz alternating Tone 2 Tone 5 Tone 22 544Hz @ 0.875 sec. intermittent Tone 2 Tone 5 Tone 23 800Hz @ 2Hz intermittent Tone 6 Tone 5 Tone 24 800 / 1000Hz @ 50Hz sweeping Tone 29 Tone 5 Tone 25 2400 / 2900Hz @ 50Hz sweeping Tone 29 Tone 5 Tone 26 Bell Tone 2 Tone 15 Dimensions 95.00 99.00 Ø88.70 85.50 A/F M20 Cable Entry M20 Cable Entry

Ex ia Audible Alarms Configuration continued Tone 27 554Hz continuous Tone 26 Tone 5 Tone 28 440Hz continuous Tone 2 Tone 5 Tone 29 800 / 1000Hz @ 7Hz sweeping Tone 7 Tone 5 Tone 30 300Hz continuous Tone 2 Tone 5 Tone 31 600 / 1200Hz @ 1Hz sweeping Tone 26 Tone 5 Tone 32 Two tone chime Tone 26 Tone 15 Tone 33 745Hz @ 1Hz intermittent Tone 2 Tone 5 Tone 34 1000 & 2000Hz @ 0.5 sec alternating Singapore Tone 38 Tone 45 Tone 35 420Hz @ 0.625 sec Austrailian alert Tone 36 Tone 5 Tone 36 500 1200Hz 3.75 sec / 0.25 sec. Austrailian evac. Tone 35 Tone 5 Tone 37 1000Hz continuous PFEER toxic gas Tone 9 Tone 45 Tone 38 2000Hz continuous Tone 34 Tone 45 Tone 39 800Hz 0.25 sec on, 1 sec off intermittent Tone 23 Tone 17 Tone 40 544Hz (100mS) / 440Hz (400mS) NF S 32001 Tone 31 Tone 27 Tone 41 Motor Siren slow rise to 1200Hz Tone 2 Tone 5 Tone 42 Motor Siren slow rise to 800Hz Tone 2 Tone 5 Tone 43 1200Hz continuous Tone 2 Tone 5 Tone 44 Motor Siren slow rise to 2400Hz Tone 2 Tone 5 Tone 45 1KHz 1s on, 1s off intermittent PFEER Gen. alarm Tone 38 Tone 34 Tone 46 1200 / 500Hz @ 1Hz DIN / PFEER P.T.A.P Tone 47 Tone 37 Tone 47 1KHz 1s on, 1s off intermittent PFEER Gen. alarm Tone 46 Tone 37 Tone 48 420Hz @ 0.625 sec Austrailian alert Tone 49 Tone 5 Tone 49 500 1200Hz 3.75 sec / 0.25 sec. Austrailan evac. Tone 26 Tone 37 Wiring Volume Control Tone Generator S2 S3 Tone Selection Switches Simplified block diagram

Ex ia Audible Alarms Wiring continued ISmA1 28V 93mA ISmA1 Diode Return 28V 93mA Single stage alarm using single channel barrier Single stage alarm using two channel barrier ISmA1 28V 93mA S2 S3 Diode Return 2nd Stage Diode Return 3rd Stage Multi stage alarm using Zener barriers ISmA1 Galvanic Isolator ISmA1 Galvanic Isolator S2 Galvanic Isolated Relay Single stage alarm using Galvanic Isolator Multi stage alarm using Galvanic Isolated Relays

Ex ia Visual Alarms Ex ia Visual Alarms Features II 1G Ex ia IIC T4 (40 C<=Ta<=60 C) Rated for Zone 0,1 & 2, gas group IIC ABS flame retardent UL94V0 & 5VA housings Colour: Red RAL3000 Ingress Protection: IP65 Terminals accept 0.5 to 2.5mm² cables Operating temperature: 40 to 60 C Storage temperature: 40 to 70 C Relative humidity: 90% at 50 C Installation: May be powered from any certified Zener barrier whose output parameters do not exceed: Uo: 28VDC Io: 93mA Po: 660mW or from any galvanic isolator specified by the system certificates 2 x M20 knockouts Array of 6 high intensity L.E.D s Red and amber colours available Prismatic lens optimises L.E.D effectiveness 2 flash modes: Double flash @ 2Hz and 1Hz Voltage: 1628vdc via Zener barrier or galvanic isolator End of line resistor certified Input overload and reverse current protection Current: 25mA typical when powered from 24v supply via 28v 300Ohm Zener barrier An ATEX certified intrinsically safe beacon which will produce a visual warning in a hazardous area. The beacon can be set internally for a flash rate of either 1Hz or 2Hz. Red or Amber output models are available. Dimensions 95.00 Ø88.70 85.00 M20 Cable Entry 85.50 A/F M20 Cable Entry Wiring ISmB1 28V 1.2W ISmB1 28V 93mA Diode Return Using a single channel barrier Single stage alarm using a two channel barrier ISmB1 Galvanic Isolator Basic circuit for use with a galvanic isolator

Combined Ex ia Audible/ Visual Alarms Combined Ex ia Audible/Visual Alarms Features All the features of the IS audible and visual alarms in a compact combined housing Only one Zener barrier or galvanic isolator required to run both sounder and beacon Current : 48mA typical when powered from 24v supply via 28v 300Ohm Zener barrier An ATEX certified intrinsically safe combined sounder/beacon unit which produces both a loud audio warning and a visual warning and can be installed in a hazardous area. The sounder section has fortynine first stage alarm sounds that can be selected by internal switches and each one can be externally changed to a second or third stage alarm sound. The beacon section can be set internally for a flash rate of either 1Hz or 2Hz. The combined unit sounder and beacon can be operated simultaneously from one barrier or from separate barriers if independent operation is required. The unit can be used in all gas groups IIA IIB and IIC. Dimensions Combinations of the above IS audible and visual alarms are available in a compact combined housing. Ø88.70 116.00 M20 Cable Entry 95.00 85.50 A/F M20 Cable Entry Wiring ISmC1 ISmC1 28V 93mA ISmC1 ISmC1 28V 93mA 28V 1.2W Combined Unit wired for simultaneous operation using one Zener barrier ISmC1 Galvanic Isolator Combined Unit wired for independent operation using separate Zener barriers ISmC1 Combined Unit wired for simultaneous operation using one isolator

Ordering Information Part Numbering Key HA Honeywell Analytics Part Number H Use AX Audible Alarm VX Visual Alarm AV Audible and Visual Alarm AD ATEX Ex d approved AI ATEX Ex ia approved R Red Lens A Amber Lens Example: HAHAVADR = Honeywell Analytics, hazardous area, audible and visual alarm, ATEX Ex d approved, with a red lens. (Ex d) Audible Alarms (DC) HAHAXAD 24Vdc hazardous area ATEX Ex d indoor/outdoor use audible alarm with red housing. Nominal output 110dB(A) @ 1m (adjustable), 32 alarm tones and 2xM20 gland entries Type Number: BExS110D24DC (Ex d) Visual Alarms (DC) HAHVXADR 24Vdc hazardous area ATEX Ex d indoor/outdoor use visual alarm with red housing and red lens. 5 Joule output xenon strobe, 2xM20 gland entries Type Number: BExBG05D24DCRD HAHVXADA 24Vdc hazardous area ATEX Ex d indoor/outdoor use visual alarm with red housing and amber lens. 5 Joule output xenon strobe, 2xM20 gland entries Type Number: BExBG05D24DCAM (Ex d) Audible & Visual Alarms (DC) HAHAVADR 24Vdc hazardous area ATEX Ex d indoor/outdoor use audible and visual alarm with red housing and red lens. 5 Joule output xenon strobe, audible alarm with nominal output 110dB(A) @ 1m (adjustable), 32 alarm tones 2xM20 gland entries Type Number: BEXCS11005D24DCRD HAHAVADA 24Vdc hazardous area ATEX Ex d indoor/outdoor use audible and visual alarm with red housing and red lens. 5 Joule output xenon strobe, audible alarm with nominal output 110dB(A) @ 1m (adjustable), 32 alarm tones 2xM20 gland entries. Type Number: BExCS11005D24DCAM (Ex ia) Audible Alarms (DC) HAHAXAI 24Vdc hazardous area ATEX Ex ia indoor/outdoor use audible alarm with red housing. Nominal output 100dB(A) @ 1m (adjustable), 49 alarm tones and 2xM20 gland entries Type Number: ISMA1R (Ex ia) Visual Alarms (DC) HAHVXAIR 24Vdc hazardous area ATEX Ex ia indoor/outdoor use LED visual alarm with red housing and red lens. 2xM20 gland entries. Type Number: ISMB1R/R HAHVXAEA 24Vdc hazardous area ATEX Ex ia indoor/outdoor use LED visual alarm with red housing and amber lens. 2xM20 gland entries. Type Number: ISMB1R/A (Ex ia) Combined Audible & Visual Alarms (DC) HAHAVAIR 24Vdc hazardous area ATEX Ex ia indoor/outdoor use audible alarm with red housing. Nominal output 105dB(A) @ 1m (adjustable), 49 alarm tones and 1xM20 gland entry and 24Vdc hazardous area ATEX Ex ia indoor/outdoor use LED visual alarm with red housing and red lens. 2xM20 gland entries. Type Number: ISMC1R/R HAHAVAIA 24Vdc hazardous area ATEX Ex ia indoor/outdoor use audible alarm with red housing. Nominal output 105dB(A) @ 1m (adjustable), 49 alarm tones and 1xM20 gland entry and 24Vdc hazardous area ATEX Ex ia indoor/outdoor use LED visual alarm with red housing and Amber lens. 2xM20 gland entries. Type Number: ISMC1R/A

Our Product Range Fixed Gas Monitoring Portable Gas Monitoring Technical Services Honeywell Analytics offers a wide range of fixed gas detection solutions for a diverse array of industries and applications Find including: out more Commercial properties, industrial www.honeywellanalytics.com applications, semiconductor manufacturers, energy plants and petrochemical sites. Contact Honeywell Analytics:» Detection of flammable, oxygen and toxic gases (including exotics) Europe, Middle East, Africa, India» Innovative use of 4 core sensing Life Safety Distribution AG technologies paper tape, Weiherallee 11a electrochemical cell, catalytic bead CH8610 and Uster infrared Switzerland» Capability to detect down to Parts Per Tel: 41 (0)44 943 4300 Billion (ppb) or Percent by Volume (%v/v) Fax: 41 (0)44 943 4398» Cost effective regulatory compliance India Tel: 91 124 4752700 solutions gasdetection@honeywell.com Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: Find 1 out 847 more 955 8200 Toll www.honeywellanalytics.com free: 1 800 538 0363 Fax: 1 847 955 8210 detectgas@honeywell.com Contact Honeywell Analytics: When it comes to personal protection from gas hazards, Honeywell Analytics has a wide range of reliable solutions ideally suited for use in confined or enclosed spaces. These include:» Detection of flammable, oxygen and toxic gases» Single gas personal monitors worn by the individual» Multigas portable gas monitors used for confined space entry and regulatory compliance Find» out Multigas more transportable monitors used for temporary protection of area www.honeywellanalytics.com during site construction and maintenance activities Contact Honeywell Analytics: Europe, Middle East, Africa, India Life Safety Distribution AG Weiherallee 11a CH8610 Uster Switzerland Tel: 41 (0)44 943 4300 Fax: 41 (0)44 943 4398 India Tel: 91 124 4752700 gasdetection@honeywell.com At Honeywell Analytics, we believe in the value of great service and customer care. Our key commitment is providing complete Find and out total more customer satisfaction. Here are just www.honeywellanalytics.com a few of the services we can offer: Contact» Full Honeywell technical support Analytics:» Expert team on hand to answer Europe, questions Middle and East, queries Africa, India Life» Safety Fully Distribution equipped workshops AG to ensure Weiherallee quick 11a turnaround on repairs CH8610» Comprehensive Uster service engineer network Switzerland» Training on product use and maintenance Tel:» 41 Mobile (0)44 calibration 943 4300service Fax: 41 (0)44 943 4398» Customised programmes of India Tel: preventative/corrective 91 124 4752700 maintenance gasdetection@honeywell.com» Extended warranties on products Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: 1 847 955 8200 Toll free: 1 800 538 0363 Fax: 1 847 955 8210 detectgas@honeywell.com Asia Europe, Pacific Middle East, Africa, India Honeywell Life Safety Analytics Distribution Asia AGPacific #508, Weiherallee Kolon 11a Science Valley (I) 18710 CH8610 GuroDong, Uster GuroGu Seoul, Switzerland 152050 Korea Tel: 41 (0)44 943 4300 Tel: Fax: 82 41 (0)2 (0)44 6909 9430300 4398 Fax: India 82 Tel: (0)2 91 2025 124 4752700 0329 analytics.ap@honeywell.com gasdetection@honeywell.com Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: 1 847 955 8200 Toll free: 1 800 538 0363 Fax: 1 847 955 8210 detectgas@honeywell.com Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (I) 18710 GuroDong, GuroGu Seoul, 152050 Korea Tel: 82 (0)2 6909 0300 Fax: 82 (0)2 2025 0329 analytics.ap@honeywell.com Technical Americas Services EMEAI: Honeywell HAexpert@honeywell.com Analytics Inc. US: 405 Barclay ha.us.service@honeywell.com Blvd. AP: Lincolnshire, ha.ap.service@honeywell.com IL 60069 USA www.honeywell.com Tel: 1 847 955 8200 Toll free: 1 800 538 0363 Please Fax: Note: 1 847 955 8210 Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (I) 18710 GuroDong, GuroGu Seoul, 152050 Korea Tel: 82 (0)2 6909 0300 Fax: 82 (0)2 2025 0329 While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. detectgas@honeywell.com analytics.ap@honeywell.com Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. Asia Pacific Technical Services H_ Audible and Visual Alarms_DS01086_V1_EMEAI Honeywell Analytics Asia Pacific EMEAI: HAexpert@honeywell.com 09/11 #508, 2011 Honeywell Kolon Science Analytics Valley (I) 18710 GuroDong, GuroGu Seoul, 152050 US: AP: ha.us.service@honeywell.com ha.ap.service@honeywell.com Korea www.honeywell.com Technical Services EMEAI: HAexpert@honeywell.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com www.honeywell.com 12556