SIMATIC NET Introduction S7-1413



Similar documents
Appendix A - Values of rb_response with Windows 95, Windows NT and MS-DOS. Appendix B - Error Messages of the SEND/RECEIVE Functions

SIMATIC. Communication with SIMATIC. 1 Introduction and Basics of Communication. 2 Communication Services. 3 Communication Networks

CONNING DISPLAY (Box -Pc)

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. Installation Instructions. INSTALLATION INSTRUCTIONS for the CP 5412 (A2) C79000-Z8974-C Stand / Dated 04/98

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

SIMATIC NET. DP Base Programming Interface for CP 5613/CP Preface, Contents. Basic Steps in Creating a DP Application 1

ESD Plastic light pallet Doc. Num. N x 800 x 150 mm Doc. Part 001 Doc. Ver. 01. Contents

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

How To Write A Profibus Dpl (Profibus) Program

SIMATIC NET. S7-CPs for Industrial Ethernet Configuring and Commissioning

Continental Automotive Trade Terms Doc. Type TST CA-DAP & CA-DDP Doc. Num. N For Suppliers Date: Page 1 of 7 CONTENTS

8/23/13 Configuring the S7 I/O Server for Windows 95 to Access S7 PLCs Via the Profibus Network

NZQA Expiring unit standard 6857 version 4 Page 1 of 5. Demonstrate an understanding of local and wide area computer networks

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

The CP FO provides access to different communication services of the PROFIBUS bus system:

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

WinCC Options. Redundancy. Manual C79000-G8263-C142-01

Permissible ambient temperature Operation Storage, transport

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup.

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

WinCC. Configuration Manual. Manual Volume 3

CP Page 1342 Mar 2008 Siemens ITS

FAQ Communication over IE

SIMOVERT MASTERDRIVES Vector Control Wechselrichter (DC-AC) Bauform Einbaugerät Inverter (DC-AC) Chassis Type

CPU SHB210 BIOS Versionen V14.x

The CP provides access to different communication services of the PROFIBUS bus system:

8/23/13 Configuring the S7 Server for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP1613 Card for ISO (Industrial Ethernet)

EPSON Scan Server & EPSON TWAIN Pro Network

CPUs - CPU PN/DP

Vorlesung Kommunikationsnetze Fieldbus Systems

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning

DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS

SIMATIC. System Software for S7-300 and S7-400 Program Design A B C D. Programming Manual C79000-G7076-C Preface, Contents

Computer Network. Interconnected collection of autonomous computers that are able to exchange information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE C2. High Level Programming with S7-SCL

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Documentation. M-Bus 130-mbx

SIMATIC NET. Step by Step: Ethernet Communication between OPC Server and S7-200 incl. CP Overview and Environment. Contents

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Network Technologies

The OSI Model: Understanding the Seven Layers of Computer Networks

Powerline Network. RPL-85 User Manual RPL-85. Powerline Ethernet Bridge V All rights reserved. Page 1

WinCC. Configuration Manual. Manual Volume 2

SIMATIC. Open TCP/IP Communication via Industrial Ethernet. Contents Open TCP/IP Communication via Industrial Ethernet 1. Index.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

ETNALC Installation Manual

Parameterization, Configuration and Visualization with SIRIUS

PLC-ANALYZER pro 5. PLC-Driver Siemens SIMATIC S5 Industrial Ethernet TCP/IP. Driver-Addendum. The logic analyzer for programmable logic controls

FAQ Communication over IE

Ethernet/IP Comms between a WAGO and a Mettler Toledo JAGXTREME Terminal Application note

WHITEPAPER. Image processing in the age of 10 Gigabit Ethernet

Introduction to Ethernet

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

TECHNICAL NOTE TNOI34

SIMATIC PDM V6.0. Getting Started Edition 12/2004

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

S7 for Windows S7-300/400

SAN Conceptual and Design Basics

1 Application Description Objective Goals... 3

SIMATIC PDM software. Siemens FI /1

Integrating Computer and Technology Systems Networks in Industrial Technology Programs

PROFINET IO Diagnostics 1

Industrial Networks & Databases

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions

Application note. A103202, English Version 1.0.1

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

Transmitting s in a local network with a WAGO CONTROLLER Application note

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

FINAL DRAFT INTERNATIONAL STANDARD

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

SFWR 4C03: Computer Networks & Computer Security Jan 3-7, Lecturer: Kartik Krishnan Lecture 1-3

Connect Ethernet-Controller to TO-PASS web portal via GPRS-Router Application note

Development of a Gateway to PROFIBUS for Remote Diagnostics

SIMATIC HMI. WinCC flexible Getting Started First Time User. Order number 6ZB5370-1CL02-0BA2. Edition 04/2006 A5E

Security & Chip Card ICs SLE 44R35S / Mifare

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

S7 OPC Server Tutorial

Grid Automation Products. SAM600 Process Bus I/O System Cyber Security Deployment Guideline

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA) MODULE M1

Protocols and Architecture. Protocol Architecture.

Computer Networks. Definition of LAN. Connection of Network. Key Points of LAN. Lecture 06 Connecting Networks

Configuring PROFINET

2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 D. None of the above

PROFINET the Industrial Ethernet standard. Siemens AG Alle Rechte vorbehalten.

BK MIKRO9. Tool monitoring system. Getting Started with Profibus Release 1.00 /

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE A5. PLC-Simulation with S7-PLCSIM

Transcription:

SIMATIC NET Introduction S7-1413 Manual 1 Overview 2 Description of the Architecture 3 Where to Obtain Help Glossary C79000-G8976-C107 Release 1 SIMATIC NET is a trademark of Siemens Siemens Aktiengesellschaft

Wir haben den Inhalt der Druckschrift auf Übereinstimmung mit der beschriebenen Hard- und Software geprüft. Dennoch können Abweichungen nicht ausgeschlossen werden, so daß wir für die vollständige Übereinstimmung keine Gewähr übernehmen. Die Angaben in der Druckschrift werden jedoch regelmäßig überprüft. Notwendige Korrekturen sind in den nachfolgenden Auflagen enthalten. Für Verbesserungsvorschläge sind wir dankbar. Technische Änderungen vorbehalten. Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten, insbesondere für den Fall der Patenterteilung oder GM-Eintragung. Copyright Siemens AG 1996 All Rights Reserved We have checked the contents of this manual for agreement with the hardware described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcome. Technical data subject to change. The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility or design, are reserved. C79000-G8976-C107 Copyright Siemens AG 1996 All Rights Reserved Nous avons vérifié la conformité du contenu du présent manuel avec le matériel et le logiciel qui y sont décrits. Or, des divergences n'étant pas exclues, nous ne pouvons pas nous porter garants pour la conformité intégrale. Si l'usage du manuel devait révéler des erreurs, nous en tiendrons compte et apporterons les corrections nécessaires dès la prochaine édition. Veuillez nous faire part de vos suggestions. Nous nous réservons le droit de modifier les caractéristiques techniques. Toute communication ou reproduction de ce support d informations, toute exploitation ou communication de son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommages et intérêts. Tous nos droits sont réservés, notamment pour le cas de la délivrance d'un brevet ou celui de l'enregistrement d'un modèle d'utilité. Copyright Siemens AG 1996 All Rights Reserved Siemens Aktiengesellschaft Elektronikwerk Karlsruhe Printed in the Federal Republic of Germany

SIMATIC NET Introduction S7-1413 Manual C79000-B8976-C112

Note We would point out that the contents of this product documentation shall not become a part of or modify any prior or existing agreement, commitment or legal relationship. The Purchase Agreement contains the complete and exclusive obligations of Siemens. Any statements contained in this documentation do not create new warranties or restrict the existing warranty. We would further point out that, for reasons of clarity, these operating instructions cannot deal with every possible problem arising from the use of this device. Should you require further information or if any special problems arise which are not sufficiently dealt with in the operating instructions, please contact your local Siemens representative. General WARNING!! This device is electrically operated. In operation, certain parts of this device carry a dangerously high voltage. Failure to heed warnings may result in serious physical injury and/or material damage. Only appropriately qualified personnel may operate this equipment or work in its vicinity. Personnel must be thoroughly familiar with all warnings and maintenance measures in accordance with these operating instructions. Correct and safe operation of this equipment requires proper transport, storage and assembly as well as careful operator control and maintenance. Personnel qualification requirements Qualified personnel as referred to in the operating instructions or in the warning notes are defined as persons who are familiar with the installation, assembly, startup and operation of this product and who posses the relevant qualifications for their work, e.g.: Training in or authorization for connecting up, grounding or labeling circuits and devices or systems in accordance with current standards in safety technology; Training in or authorization for the maintenance and use of suitable safety equipment in accordance with current standards in safety technology; First Aid qualification.

B8976112 Introduction S7-1413 Contents 1 Overview...3 1.1 What is S7-1413...4 1.2 Using S7-1413...5 1.3 User Experience...6 1.4 Guide to the Documentation...7 2 Description of the Architecture...9 2.1 SIMATIC NET Communication Networks...10 2.2 SIMATIC NET for Industrial Ethernet...11 2.3 Computer Structure of the Soft and Hardware Components...12 2.4 SAPI-S7...13 2.5 SEND/RECEIVE Programming Interface...15 3 Where to Obtain Help...17 3.1 Help with Technical Questions...18 3.2 Contacts for SIMATIC NET Training...19 Glossary...20 1

Introduction S7-1413 B8976112 Notes for the User Documentation The documentation for this products S7-1413/Windows 95 and S7-1413/Windows NT consists of three volumes with the following titles: Introduction S7-1413 (this volume), Configuring the S7 mode with COML S7 S7 programming interface. SEND/RECEIVE programming interface Conventions The following symbol is used in the text. This symbol highlights special features and dangers. 2

B8976112 Introduction S7-1413 1 Overview SIEMENS developed the SIMATIC NET communications for automation engineering. This is a system of high-performance Local Area Networks (LANs), for example SIMATIC NET for Industrial Ethernet, SIMATIC NET for PROFIBUS and SIMATIC NET for AS- Interface. S7-1413 supports both the ISO Transport protocol in accordance with ISO 8073 as well as the TCP/IP protocol with the RFC 1006 supplement. The user interface remains unaffected. In the world of SIMATIC NET communication, SAPI S7 is used for communication between personal computers or programming devices and the components of SIMATIC S7. 3

Introduction S7-1413 B8976112 1.1 What is S7-1413 Function With the SIMATIC NET S7-1413 product, you can attach personal computers (PCs) and programming devices (PGs) to SIMATIC S7 systems via the Industrial Ethernet industrial communication ne twork. SAPI S7 Interface The interface to the user program implemented by S7-1413 is known as SAPI S7. This has the following features: It is a simple C programming interface. It provides access to S7 services on PCs and PGs. It is available as a C library and is operated with SIMATIC NET drivers and SIMATIC NET communications processors. Adapter S7-1413 can only be operated with the network card SIMATIC NET CP 1413. Simultaneous operation of more than one network card is possible with a suitable hardware configuration. Operating System S7-1413 can only be operated under Microsoft Windows 95 or Windows NT, Version 4.0 or higher. 4

B8976112 Introduction S7-1413 1.2 Using S7-1413 Environment S7-1413 can be used in all PCs or PGs in which a CP 1413 can be operated. PG Operation on Industrial Ethernet To operate S7-1413 on Industrial Ethernet, you can use the standard SIMATIC NET components, such as: Transceivers Drop Cables Fan-out units etc. S7-1413 S7-1413 is the basis for communication for application programs with the following tasks: Detecting and modifying machine statuses Keeping production statistics Archiving process data Visualizing process 5

Introduction S7-1413 B8976112 1.3 User Experience User Groups The product is used mainly by two user groups: Users of S7 applications Programmers of S7 applications Programmers of SEND/RECEIVE applications Required Experience The user group broadly labeled Users of S7 Applications does not, of course, require the same depth of knowledge as Programmers of S7 Applications. The following table indicates the experience required by the user groups. Necessary Experience Users of S7 or SR Applications Programmers of S7 or SR Applications Familiar with PCs yes yes Familiar with the SIMATIC S5 or S7 systems Experience with a programming language yes no yes yes (C programming language an advantage) 6

B8976112 Introduction S7-1413 1.4 Guide to the Documentation For All Users We recommend all users to read the following documentation: This manual (S7-1413) The Installation Instructions S7-1413/Windows 95 or S7-1413/Windows NT The Product Information S7-1413/Windows 95 or S7-1413/Windows NT Configuring the S7 Mode with COML S7 manual. For Programmers of S7 Applications We also advise programmers of S7 applications to read the S7 Pr o- gramming Interface manual. For Programmers of SEND/RECEIVE Applications We also advise programmers of SEND/RECEIVE applications to read the SEND/RECEIVE Programming Interface manual. 7

Introduction S7-1413 B8976112 Notes 8

B8976112 Introduction S7-1413 2 Description of the Architecture The following chapter describes the properties and functions of the S7-1413 software package. The chapter contains the following: An overview of the various communications networks available from Si emens Basic information about SIMATIC NET for Industrial Ethernet An overview of SAPI S7 An overview of the SEND/RECEIVE programming interface 9

Introduction S7-1413 B8976112 2.1 SIMATIC NET Communication Networks The Areas of Application of SIMATIC NET SIMATIC NET is an open, heterogeneous communication system with a variety of Local Area Networks (LANs) providing various ranges of pe r- formance for manufacturing and process automation in industry. It is based on national and international standards according to the ISO/OSI reference model. SIMATIC NET Communication Networks SIMATIC NET provides the following communications networks for different requirements (Figure 2-1): Industrial Ethernet - a cell and management network based on IEEE 802.3. PROFIBUS (Process Field Bus) - a cell and field level communication network based on DIN 19245, Parts 1, 2 and 3. AS-i (Actuator Sensor Interface) - a communication network for the actuator and sensor level. Management level Cell level Industrial Ethernet Field level PROFIBUS Actuator-sensor level AS-Interface Figure 2-1 SIMATIC NET Communication Networks 10

B8976112 Introduction S7-1413 2.2 SIMATIC NET for Industrial Ethernet Area of Application of SIMATIC NET for Industrial Ethernet The cell and area network Industrial Ethernet is an industrial commun i- cation network designed for use in manufacturing and in industrial plants. It provides a wide range of network components for electrical and optical transmission of data. Basis The cell and area network Industrial Ethernet is based on the IEEE 802.3 (Ethernet) standard. It operates using the CSMA/CD access technique (Carrier Sense Multiple Access with Collision Detection). Network Components Industrial Ethernet network segments implement electrical networks using single shielded coaxial bus cables (triaxial cable). Optical Network Components The optical network components implement optical networks using fiber optic cables. The advantage of optical networks is that optical network segments are immune to electrical interference and that large distances can be covered. 11

Introduction S7-1413 B8976112 2.3 Computer Structure of the Soft and Hardware Components The Software and Hardware Components under Windows 95, Windows NT STEP 7 Application SR Application SR-DLL S7 Application S7-DLL Access DLL RFC 1006 TCP/IP driver (WINSOCK.DLL) Driver for Industrial Ethernet NIC CP 1413 NIC for Industrial Ethernet to be created by the user Figure 2-2Software and Hardware Components under Windows 95, Windows NT 12

B8976112 Introduction S7-1413 2.4 SAPI-S7 What Does SAPI-S7 Mean? The acronym SAPI-S7 stands for the following: SAPI - Simple Application Programmers Interface S7 - the Layer 7 communications protocol of SIMATIC S7 systems What is SAPI-S7? SAPI-S7 has the following features: It is a simple C programming interface. It provides access to the S7 services on PCs and PGs. It is available as a C library and is operated with SIMATIV NET drivers and communications processors. Communications with SIMATIC S7 Programmable Controllers Communication with SIMATIC-S7 is best handled with the S7 programming interface. The call structure and the sequence of communication with the SIMATIC S7 programmable controllers are described in detail in the "S7 Programming Interface" ma nual. Advantages of the SAPI-S7- Programming Interface The SAPI-S7 programming interface has the following advantages: SAPI-S7 is a simple but nevertheless flexible and high-performance interface. The SAPI-S7 programming interface is designed for asynchronous operation. SAPI-S7 handles sequential services automatically such as active or passive S7 connection establishment. SAPI-S7 supports troubleshooting with an integrated trace function. The SAPI-S7 programming interface is compatible with other SAPI programming interfaces. The SAPI-S7 programming interface can also be used by other pr o- grams for example Visual Basic or Pascal programs. The S7 programming interface offers significantly more user-friendly communications functions than the SEND/RECEIVE programming interface; for example "Read/write variables". Compatibility The SAPI-S7 programming interface of S7-1413 is also available for communication on PROFIBUS. All programs equipped with the SAPI-S7 interface therefore have un i- form access to SIMATIC S7 syst ems. 13

Introduction S7-1413 B8976112 Programmer Support To make it easier for programmers to familiarize themselves with the use of SAPI-S7 in the software packages of S7-1413, the following is provided in addition to the documentation already mentioned: Sample programs A call library Sample Programs Sample programs are provided with S7-1413. They are written in the "C" programming language. The mode of operation of the interface can be discerned from the program context of the sample programs. Also, sections of the sample programs can be taken over in analogous contexts. Call Library Of further help is the call library for SAPI-S7 interface function calls, written in "C" and included in the scope of supply. For "C" programmers, this means: the call library can be integrated direct into your own software the related calls can be used direct, as described in detail in the sample programs The sample programs and functions calls provide a second practical description, in addition to the explanation in the manual, of the data structures required. 14

B8976112 Introduction S7-1413 2.5 SEND/RECEIVE Programming Interface SEND/RECEIVE It is a C programming interface, which provides access to the SEND/RECEIVE services on PCs and PGs. Compatibility The SEND/RECEIVE programming interface is a layer 4 (Transport layer) interface. Communications with SIMATIC S5 Programmable Controllers There is easy problem-free communication with the data handling blocks of the SIMATIC-S5 programmable controllers via the calls of the SEND/RECEIVE programming interface. The call structure and the sequence of communication with the SIMATIC S5 programmable controllers are described in detail in the "SEND/RECEIVE Programming Interface" manual. Advantages of the SEND/RECEIVE Programming Interface All programs equipped with the SEND/RECEIVE interface have easy access to SIMATIC-S5 programmable controllers. Programmer Support To make it easier for programmers to familiarize themselves with the use of SEND/RECEIVE in the software packages of S7-1413, the following is provided in addition to the documentation already mentioned: Sample programs A call library Sample Programs Sample programs are provided with S7-1413. They are written in the "C" programming language. The mode of operation of the interface can be discerned from the program context of the sample programs. Also, sections of the sample programs can be taken over in analogous contexts. 15

Introduction S7-1413 B8976112 Call Library Of further help is the call library for SEND/RECEIVE interface function calls, written in "C" and included in the scope of supply. For "C" programmers, this means: the call library can be integrated direct into your own software the related calls can be used direct, as described in detail in the sample programs The sample programs and functions calls provide a second practical description, in addition to the explanation in the manual, of the data structures required (request block in the case of SEND/RECEIVE). 16

B8976112 Introduction S7-1413 3 Where to Obtain Help This chapter lists SIMATIC NET contacts: Contacts for technical questions Contacts for training in SIMATIC NET products 17

Introduction S7-1413 B8976112 3.1 Help with Technical Questions Documentation You will find information about topics related to using this software in the following sources: In the relevant printed documentation In the help system integrated in the software (F1 key) In text files on the diskette(s) supplied Who to Contact If you have technical questions about using the software and your problem is not dealt with in the documentation or in the integrated help system, please contact your Siemens representative or dealer. The addresses are listed in the following: in our Catalog IK 10 in CompuServe (go autforum > library area SIMATIC NET) on the Internet (http://www.aut.siemens.de) Common Questions Our customer support on the Internet provides useful information and answers to common questions. Under FAQ ( Frequently Asked Questions), you will find a variety of information about our entire range of products. The address of the AUT homepage in the worldwide web of Internet is: http://www.aut.siemens.de/net Hotline If you have problems, you can also contact our hotline: Telephone: 0911-895 - 7000 (from abroad +49-911 - 895-7000) Telefax: 0911-895 - 7001 (from abroad +49-911 - 895-7001) E-Mail: Mailbox simatic.support@nbgm.siemens.de (BBS, analog/isdn, 8N1): 0911-895 - 7100 (vom Ausland +49-911 - 895-7100) 18

B8976112 Introduction S7-1413 3.2 Contacts for SIMATIC NET Training Course Enrollment Siemens AG Trainings-Center für Automatisierungstechnik AUT 959 Kursbüro Östliche Rheinbrückenstraße 50 76181 Karlsruhe Telephone 0721-595 - 2917 from abroad +49-721 - 595-2917 Fax 0721-595 - 6987 from abroad +49-721 - 595-6987 19

Introduction S7-1413 B8976112 Glossary AS-i Actuator-Sensor Interface - a cable for direct connection of simple b i- nary sensors and actuators (transmission of small amounts of inform a- tion - previously: SINEC S1). COML CSMA/CD CP DB DPRAM Configuration Management local - Configuration software for SIMATIC NETC communications processors. Carrier Sense Multiple Access/Collision Detection - access technique for bus systems complying with IEEE 802.3 (Ethernet). Communications Processor - module for installation in computers or programmable logic controllers. Database - the local database describes the communication network from the point of view of the local system. The database is accessed by system routines when the connection is established. Dual-Port Random Access Memory - allows simultaneous access by two devices (CP and CPU) to one memory chip (RAM). Driver Software required for the data transfer between applications and the -> CP. ESD Guidelines FO IEEE Electrostatically sensitive devices - guidelines for handling electrostatically sensitive devices. Fiber Optic Institute of Electrical and Electronics Engineers Industrial Ethernet Cell network complying with the international standard IEEE 802.3 (Ethernet) designed for use in an industrial environment (previously SINEC H1). IRQ ISA ISO LAN MAC Interrupt Request Industrial System Architecture - PC bus standard; ISA Bus - expansion bus for XT and AT computers. International Standards Organization - international organization based in Geneva responsible for creating general standards particularly in the filed of data transmission. Local Area Network for direct connection of computers. Media Access Control - techniques for controlling access by a station to a common transmission medium. 20

B8976112 Introduction S7-1413 MAC Address Address to distinguish different stations on a commonly used transmi s- sion medium. MMS Multicast Address Network PC PG PDU PROFIBUS Protocol RFC 1006 SAPI S7 Manufacturing Message Specification - user interface of MAP. The multicast address is an address for a particular group of stations. A network consists of one or more interconnected subnets with any number of stations. Several networks can exist side by side. There is a common node table for every subnet. Personal Computer Programming device - a programming device of the SIMATIC product range produced by Siemens AG; used for programming and configur a- tion and for maintenance and service. Protocol Data Unit - user data plus control information belonging to a layer of the ISO 7-layer model. Process Field Bus - a field bus complying with DIN 19245 (previously SINEC L2). A set of rules governing data transmission. Using these rules, both the formats of the messages and the data flow during transmission can be specified. RFC 1006 is an international standard that describes the mode of operation of ISO layer 4 on TCP. C programming interface, which provides access to S7 services on PCs and PGs. S7 PLC Abbreviation for a programmable logic controller of the SIMATIC pro d- uct range produced by Siemens AG. Services SIMATIC NET SIMATIC NET for Industrial Ethernet SIMATIC NET or PROFIBUS System SR Interface Services provided by a communication protocol. New name of the SINEC range of products. SIMATIC NET bus system for industrial applications based on Ethernet. SIMATIC NET bus system for industrial applications based on PROFIBUS. All the electrical equipment within a system. A system includes, among other things, programmable logic controllers, devices for operation and monitoring, bus systems, field devices, actuators, supply lines. SEND/RECEIVE programming interface, also known as the PC -E-S5 programming interface. 21

Introduction S7-1413 B8976112 TCP/IP TF TPDU TSAP Transmission Control Protocol/Internet Protocol - standardized protocol of the transport layer or network layer (OSI) for communications between programs of different DP systems. Technological Functions - MMS-compatible user services in SIMATC NET. Transport Protocol Data Unit - presentation of a message from the transport system (layer 4) of the sender to the transport system of the receiver (layer 4). Transport Service Access Point - identifies an access point for the services of the transport protocol in individual stations. 22