HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile



Similar documents
Medium voltage insulator

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

DS 600. A contact free flux gate based current measurement sensor 600A rms

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Design Test Report Veri*Lite Suspension Insulators Catalog Numbers: , , ,

Composite Insulators Suspensions Line Posts Brace Posts Station Posts

CABLE ACCESSORIES kv

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Transformer Bushings for GIS

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Pluggable interface relays CR-P Pcb relays

Sediver toughened glass suspension insulators catalog

SURGE PROTECTIVE DEVICES

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A

Veri*Lite Deadend & Suspension Insulators for 15-69kV Applications

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

Design Test Report Report No. EU1531-H ANSI C29.18 PROTOTYPE/ CEA LWIWG 02 DESIGN TEST REPORT Silicone Rubber 69 kv Veri*Lite Line Post 80S069

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Transmission Silicone Insulators Line Post 69 kv to 161 kv

3FL Silicone Long Rod Insulators for Distribution and Transmission Overhead Power Lines

EDITION 2012 CABLE SYSTEMS

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

IEC Type Test Report Report No. EU1522-H-00.1 PH4 Series Polymer-housed Arrester 20,000 A Line Discharge Class 4

COAX Cables Radio Frequency Cables

Design and testing of polymer-housed surge arresters with special emphasize on seismic stresses and selection of specific creepage in costal areas.

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Unified requirements for systems with voltages above 1 kv up to 15 kv

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

How To Use A Corona Mdi 110

DS1 Diode-based transient-free capacitor switch

GLASS SUSPENSION INSULATOR

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Power transformers. Special transformers Railway

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

Safety technique. Emergency stop module BO 5988 safemaster

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

a Nexans company Catalogue 2014

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

Why Buy HVI VLF Products?

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

PIN IN PASTE APPLICATION NOTE.

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

EFFECTS OF CORONA RING DESIGN ON ELECTRIC FIELD INTENSITY AND POTENTIAL DISTRIBUTION ALONG AN INSULATOR STRING

Power Meter Series 700

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Keystone Network Isolator with ESD- and Lightning Protection

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

HTV SILICONE COMPOSITE INSULATORS FOR HVDC APPLICATIONS - LONG- TERM EXPERIENCES WITH MATERIAL AND DESIGN FOR 500KV AND ABOVE

49 Series - Relay interface modules A. Features

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Pulse Withstanding Thick Film Chip Resistor-SMDP Series. official distributor of

High-ohmic/high-voltage resistors

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

Charge Controller CC611/CC612 Preliminary datasheet

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

VDE-approved PVC-Control Cables

VIPERFLEX ELECTRIC CABLE

INTERNATIONAL STANDARD

High Voltage Electrical Equipment Failure Diagnosis. Presented by: Spencer Tang & Terence Ng T&T Inspection & Engineering Sdn Bhd

The very Best. ANSI Post Insulators 2016

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Voltage Regulator SPAU 341 C. Product Guide

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

High-ohmic/high-voltage resistors

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Mounting Instructions. Torque Transducer. A en

Hi*Lite XL Transmission Insulators

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

AC axial fans A series

Transcription:

U70BS and U70BL type IEC 60305 U70BS U70BL GOST 27661 ПС70Е ПС70Е Minimum mechanical failing load kn 70 70 Minimum mechanical residual strength kn 56 56 Diameter of the insulating part, D mm 255 255 Nominal creepage distance mm 320 320 50 Hz withstand voltage (dry) kv 70 70 50 Hz withstand voltage (wet) kv 40 40 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 100/100 100/100 kv 25 25 Weight kg 3.6 3.6

U120B and U120BS type IEC 60305 U120BS U120B GOST 27661 ПС120Б ПС120Б Minimum mechanical failing load kn 120 120 Minimum mechanical residual strength kn 96 96 Diameter of the insulating part, D mm 255 255 Nominal creepage distance mm 320 320 50 Hz withstand voltage (dry) kv 70 70 50 Hz withstand voltage (wet) kv 40 40 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 100/100 100/100 kv 30 30 Weight kg 3.9 3.9

U120BS2 and U120B2 type IEC 60305 U120BS2 U120B2 GOST 27661 ПС120Е ПС120Е Minimum mechanical failing load kn 120 120 Minimum mechanical residual strength kn 96 96 Diameter of the insulating part, D mm 255 255 Nominal creepage distance mm 350 350 50 Hz withstand voltage (dry) kv 70 70 50 Hz withstand voltage (wet) kv 40 40 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 100/100 100/100 kv 30 30 Weight kg 3.9 3.9

U160BS and U160BL type IEC 60305 U160BS U160BL GOST 27661 ПС160Д ПС160Д Minimum mechanical failing load kn 160 160 Minimum mechanical residual strength kn 128 128 Diameter of the insulating part, D mm 280 280 Spacing, H mm 146 170 Nominal creepage distance mm 385 385 Ball and socket coupling, d (IEC 60120) mm 20 20 50 Hz withstand voltage (dry) kv 72 72 50 Hz withstand voltage (wet) kv 45 45 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 110/110 110/110 kv 35 35 Weight kg 6.2 6.2

U210B and U210BL type IEC 60305 U210B U210BL GOST 27661 ПС210В ПС210В Minimum mechanical failing load kn 210 210 Minimum mechanical residual strength kn 168 168 Diameter of the insulating part, D mm 290 290 Spacing, H mm 170 195 Nominal creepage distance mm 380 380 Ball and socket coupling, d (IEC 60120) mm 20 20 50 Hz withstand voltage (dry) kv 72 72 50 Hz withstand voltage (wet) kv 45 45 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 110/110 110/110 kv 40 40 Weight kg 7.2 7.2

U300B type IEC 60305 GOST 27661 U300B ПС300В Minimum mechanical failing load kn 300 Minimum mechanical residual strength kn 240 Diameter of the insulating part, D mm 320 Spacing, H mm 195 Nominal creepage distance mm 385 Ball and socket coupling, d (IEC 60120) mm 24 Puncture voltage in insulating medium kv 130 50 Hz withstand voltage (dry) kv 82 50 Hz withstand voltage (wet) kv 50 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 130/130 Radio interference voltage db 60 kv 20 db 86 kv 40 Weight kg 10

U120BSP and U120BP type Fog type profile IEC 60305 U120BSP U120BP GOST 27661 ПСВ120Б ПСВ120Б Minimum mechanical failing load kn 120 120 Minimum mechanical residual strength kn 96 96 Diameter of the insulating part, D mm 290 290 Nominal creepage distance mm 445 445 50 Hz withstand voltage (dry) kv 82 82 50 Hz withstand voltage (wet) kv 50 50 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 125/125 125/125 kv 30 30 Weight kg 5.7 5.7

U160BSP and U160BLP type Fog type profile IEC 60305 U160BSP U160BLP GOST 27661 ПСВ160А ПСВ160А Minimum mechanical failing load kn 160 160 Minimum mechanical residual strength kn 128 128 Diameter of the insulating part, D mm 320 320 Spacing, H mm 146 170 Nominal creepage distance mm 545 545 Ball and socket coupling, d (IEC 60120) mm 20 20 50 Hz withstand voltage (dry) kv 90 90 50 Hz withstand voltage (wet) kv 55 55 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 140/140 140/140 kv 35 35 Weight kg 8.0 8.0

U210BP and U210BLP type Fog type profile IEC 60305 U210BP U210BLP GOST 27661 ПСВ210Д ПСВ210Д Minimum mechanical failing load kn 210 210 Minimum mechanical residual strength kn 168 168 Diameter of the insulating part, D mm 320 320 Spacing, H mm 170 195 Nominal creepage distance mm 545 545 Ball and socket coupling, d (IEC 60120) mm 20 20 50 Hz withstand voltage (dry) kv 90 90 50 Hz withstand voltage (wet) kv 55 55 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 140/140 140/140 kv 40 40 Weight kg 8.5 8.5

Two-winger HV glass suspension insulator U70BSP and U70BLP type Fog type special profile IEC 60305 U70BSP U70BLP GOST 27661 ПСД70Е ПСД70Е Minimum mechanical failing load kn 70 70 Minimum mechanical residual strength kn 56 56 Diameter of the insulating part, D mm 270 270 Nominal creepage distance mm 411 411 50 Hz withstand voltage (dry) kv 75 75 50 Hz withstand voltage (wet) kv 45 45 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 110/110 110/110 kv 25 25 Weight kg 4.6 4.6

Two-winger HV glass suspension insulator U100BSP and U100BLP type Fog type special profile IEC 60305 U100BSP U100BLP GOST 27661 ПСД100В ПСД100В Minimum mechanical failing load kn 100 100 Minimum mechanical residual strength kn 80 80 Diameter of the insulating part, D mm 280 280 Nominal creepage distance mm 411 411 50 Hz withstand voltage (dry) kv 75 75 50 Hz withstand voltage (wet) kv 45 45 Dry lightning impulse withstand voltage, 1.2/50 +/- kv 100/100 100/100 kv 25 25 Weight kg 5.4 5.4