Dräger Polytron SE Ex Fixed Gas Detector



Similar documents
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

ST Explosion Protection GAS DETECTION SYSTEMS

Technical data sheet TDS0070

Terminal Boxes Series 8146

Compact pressure switch Flameproof enclosure Ex d Model PCA

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

HAZARDOUS AREA TECHNICAL GUIDE

Explosion proof enclosures

Safety instructions VEGADIS DIS81.CEIA/V****

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Terminal Box. Specifications TNCN

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Fire Alarm System Accessories

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Floodlight Range Installation Guide

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Technical Information RIA14

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Professional Series ATEX Portable Radios

ABSTRACT INTRODUCTION

Flameproof Audible Signal 115 db (A) Series YA90

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Rosemount 751 Field Signal Indicator

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Micro Motion 3098 Gas Specific Gravity Meter

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

Dräger PARAT Escape Hoods

Digital inductive conductivity transmitter

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Operating Instructions

A good connection. International approvals.

ST Introduction to Gas Detection Systems

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

TEIP11 I/P signal converter for standard signals. Measurement made easy

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Rosemount 752 FOUNDATION fieldbus Remote Indicator

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors

Plug and Socket Devices CES 63 A Series 8579

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

ST FRS Services simplified FIREFIGHTING RESCUE SAFETY. Dräger. Technology for Life

2.12. page Products for Explosion hazardous Environment

DrägerSensor & Portable Instruments Handbook 2 nd Edition

EX 2000/EX 2000 C/ GD 2000/GDP

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

Dräger X-dock Release Notes Software-Update and Manager Software 1.7.0

Linear Luminaire with LED Series EXLUX 6402/2

Ultima X Series Gas Monitors

ALTAIR 5X Multigas Detector Bid Specification

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

RAEGuard EC FGM-13XX

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Plug and Socket Devices SolConeX 16 A Series 8570

Lockout Specification BW Clip Maintenance-free single gas detector

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Inductive slot sensor

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

Application Requirement

Instructions for Safe Use

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

COMBIMASS. Technical Data COMBIMASS eco-bio +

Series 8146/5-V37 and Series 8150/5-V37

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Dräger PSS 3000 Self Contained Breathing Apparatus

Relative pressure transmitter type 520

Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements

Control and Distribution Boxes made of Stainless Steel Series 8150

S300 Series Dust Monitors

SEISMIC VELOCITY TRANSDUCER T1-40

EzFlex Combustible Gas Leak Detector Model EZ40

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Triple Waveband Infra-Red Flame Detection

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm


Classification of Hazardous Atmospheres

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

T U R B I N E G A S M E T E R

Worcester DS/DM Series UltraSwitch Switch box

Precision digital pressure gauge Model CPG1500

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

SafeSite LED RTO Area Light - UL844. for Indoor and Outdoor Industrial Applications #

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Draeger-Tubes and accuro Pump

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Transcription:

Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement is based on the heat of reaction principle, where a chemical reaction takes place in a catalytic bead (so-called pellistor) inside the sensor. D-13026-2010 By this, concentrations of flammable gases can be detected long before they tend to be ignitable, in other words: before they reach the lower explosive limit (LEL). The sensing heads are intended to be used in the harsh industrial environment and connected to a suitable central controller by means of a 3-core cable. Based on different sensor types Dräger offers three versions for different applications: On the one hand for the detection of up to 100 %LEL (where a special HT-version can be used at ambient temperatures up to 150 C), on the other hand for the detection of very low concentrations in the range 0... 10 %LEL (leak detection). EIGHT HOUSING VARIANTS The sensing heads Dräger Polytron SE Ex PR... DD and SE Ex LC... DD are available as four variants each, which differ by their junction boxes, specified by the following code: M1 - small standard housing M2 - midsize standard housing M3 - big GRP plastic housing Besides these junction boxes made of glass fiber reinforced Polyester (GRP) with type of protection e (increased safety) housing a sensor with metric ( M ) thread, a further variant with type of protection d (flameproof enclosure) is available, coded as: NPT1 - flame-proof metal housing This variant houses a sensor with NPT-thread and is intended to be used in conduit installations. The variant M2 should preferably be used in outdoor applications since the lateral cable gland may be exchanged by the stopping plug so that the cable can be inserted from the bottom. COMPREHENSIVE EXPLOSION PROTECTION The sensing heads Polytron SE Ex... DD are labeled acc. to the Directive 94/9/EC (Atex 95) as II 2G/ II 2D and thus are SCREWLESS TERMINALS The variants M1 and M2 are provided with so-called spring-type terminals which not only support easy installation but also ensure a long-term constant contact pressure - never to perform regular re-adjustments of screw terminals anymore! D-13692-2010 Sensing head Dräger Polytron SE Ex PR M1 DD D-22761-2010

02 DRÄGER POLYTRON SE EX FIXED GAS DETECTOR suitable for operation in areas with potentially explosive atmospheres of zone 1 and 2 as well as zone 21 and 22. In the same way, for world-wide applications, an IECEx-approval allows to operate these sensing heads in hazardous areas. MEASURING SIGNAL The flame-proof encapsulated gas sensor produces a mv-signal which is proportional to the gas concentration and can be evaluated by a suitable central controller (e.g. Dräger REGARD or Polytron SE Ex). Connected to the sensing head via a shielded 3-core cable of several hundreds of meters length, the central controller is intended to activate alarms if dangerous gas concentrations occur. During manufacturing these pellistors are matched in respect to optimum compensation characteristics. Since both these pellistors are catalytic the sensor is called type DD, standing for double detector with a resulting long-term stable sensor signal being nearly unaffected by ambient temperature changes. POISON RESISTANCE The pellistors which are manufactured since decades are of type PR, which means poison resistant. Based on their special construction these sensors have a longer lifetime compared to conventional sensors when being exposed to industrial atmospheres containing catalyst poisons such as sulfur-, phosphor-, lead- or siliconcompounds. MEASURING FUNCTION FOR EXPLOSION PROTECTION In conjunction with some Dräger central controller units the Dräger sensing heads Polytron SE Ex PR... DD and HT M DD are type-approved to be used in pre ventive explosion protection applications acc. to EN 1127-1. This is a customer s benefit since in case of a dangerous gas concentration a performance approved gas detection system will auto matically activate countermeasures so that explosive concentrations cannot form and the extension of hazardous areas thus decrease. By this, electrical installations can be designed more simply and in some cases even no further explosion protection measures are necessary. PELLISTOR SENSORS TYPE DD Since they are operated as precisely measuring temperature dependent resistors, the measuring beads housed in the sensor are called pellistors (from engl. pellet and resistor). A pellistor is a small bead made of very porous ceramic material which is impregnated by a special catalyst and embedding a small platinum filament. By means of an electrical current of approx. 255 ma on the one hand the platinum filament heats up the ceramic bead to roughly 450 C, on the other hand this platinum wire acts as a measuring resistor dependent on the bead s temperature. When molecules of a flammable gas penetrate into the catalytic bead they react with the activated airborne oxygen which is adsorbed in the porous ceramic and release heat of reaction causing the pellistor s temperature rising. The resulting resistance increase of some milli-ohms is proportional to the gas concentration. ENVIRONMENTAL CONDITIONS By means of a second, entirely uniform pellistor, which is especially encapsulated, any parameter affecting precise measurement is optimal compensated. This is particularly true in respect to humidity and ambient temperature. VERY SHORT RESPONSE TIMES To achieve short response times the gas entrance of the DD-sensor is not a conventional sinter disc but a thin wire mesh disc so that the gas to be detected can very quickly enter the pellistors by way of diffusion. ST-50-2006 100 90 80 70 60 50 40 30 20 %LEL Methane Hydrogen Ethylene n-pentane Propane Acetone n-hexane Ethyl acetate n-octane Toluene n-nonane 10 %LEL 0 0 10 20 30 40 50 60 70 80 90 100 This is because potentially explosive atmospheres occur seldom or even not at all when having a gas detection system like this. CALIBRATION A suitable central controller supplies the sensor with a constant current and, by means of its Wheatstone-semibridge input, converts the sensors s resistance change into a mv-signal. Before this, however, the sensor signal needs to be balanced to 0 mv when being exposed to normal clean air (zero calibration). When applying defined gas concentrations the resulting mv-signal needs to be adjusted at the central controller such that the current gas concentration is correctly displayed in %LEL. This is the procedure of span calibration. Since a pellistor-sensor reacts with different sensitivity when being exposed to different gases (s. graphics), in the presence of several gases and vapors it must be calibrated to the gas which the sensor is least sensitive to. The oxygen content of the monitored atmosphere must not be lower than 12 % by volume. Different sensitivities of a propane-calibrated pellistor sensor: 50% LEL n-nonane cause a measuring value of only 23 %LEL propane while 50 %LEL ethylene cause a measuring value of 62% LEL (schematic).

D-13693-2010 D-13690-2010 M1 M2 M1 M2 D-13681-2010 D-13696-2010 D-13687-2010 M3 D-13702-2010 NPT1 D-13684-2010 M3 D-13705-2010 NPT1 Dräger Polytron SE Ex PR... DD Dräger Polytron SE Ex LC... DD DRÄGER POLYTRON SE EX PR... DD Wherever there is a risk of flammable gas or vapor release, the sensing head Polytron SE Ex PR... DD can be used to prevent the formation of explosive atmospheres. By means of the central controller unit not only the operator is alarmed, but simultaneously counter measures (e.g. at 20 %LEL) are activated. If however the counter measure fails and the gas concentration rises, the mainalarm threshold (e.g. at 40 %LEL) is exceeded so that a shut-down is automatically activated. For this application the sensing heads Polytron SE Ex PR... DD and HT M DD with central controller units REGARD or REGARD-1 have been type tested in compliance with the EN 60079-29-1. DRÄGER POLYTRON SE EX LC... DD The sensing heads Polytron SE Ex LC... DD (LC = Low Concentration) is suitable to detect very low gas concentrations reliably. This sensing head is rather used for early leak detection of flammable gases and vapors with concentrations lower than 10 %LEL than for preventive explosion protection measures. Typical alarm thresholds are 3 %LEL and 5 %LEL, corresponding to e.g. 300 and 500 ppm n-hexane. The flame-proof encapsulated sensor contains complex amplification electronics which is especially factory-adjusted in respect to several measuring parameters. D-13699-2010 DRÄGER POLYTRON SE EX HT M DD The sensing head Polytron SE Ex HT M DD (HT = High Temperature) is intended to be used at ambient temperatures up to 150 C. This sensing head is preferably used in applications where extremely high temperatures can occur, especially for leak detection in the direct vicinity of gas turbines. The temperature resistant terminals are housed in a robust galvanized cast iron enclosure. Dräger Polytron SE Ex HT M DD

DRÄGER POLYTRON SE EX FIXED GAS DETECTOR 04 TECHNICAL DATA SENSING HEADS All sensing heads Polytron SE Ex... DD Type Sensing head with catalytic bead sensor Gases and Vapors Flammable gases and vapors in the ambient air such as methane, propane, acetone, acetylene, ammonia, petrol 065/095, benzene, 1.3-butadiene, n-butane, n-butyl acetate, diethyl ether, dimethyl ether, ethanol, ethylene (ethene), ethyl acetate, ethylene oxide, n-hexane, hydrogen, methanol, methyl ethyl ketone (MEK), methyl methacrylate, n-nonane, n-octane, n-pentane, i-propanol, propylene (propene), propylene oxide, toluene and o-xylene. Maximum cable length between sensing head and controller Polytron SE Ex: 3 x 1.5 mm 2 : 1450 m 3 x 1.0 mm 2 : 950 m 3 x 0.75 mm 2 : 700 m between sensing head and controller REGARD: 3 x 1.5 mm 2 : 700 m 3 x 1.0 mm 2 : 450 m 3 x 0.75 mm 2 : 350 m Ambient conditions atmospheric pressure: 800... 1100 mbar Expected sensor lifetime relative humidity: 5... 95 %, non-condensing > 3 years Polytron SE Ex PR... DD Full scale deflection Combined with a suitable controller - 100 % of the Lower Explosion Limit (LEL) Sensor current 240... 270 ma (preferably 255 ma) constant current produced by a suitable controller, approx. 1 W Response time (25 C) t 50 4 s, t 90 8 s (methane) t 50 4 s, t 90 9 s (propane) Measuring function (94/9/EC) Measuring function for explosion protection acc. to EN 60079-29-1 for the a.m. gases and vapors Measuring cable screened 3-core cable, core cross sections 0.5... 1.5 mm 2 outer diameter 7... 12 mm - exception: Sensing head Polytron SE Ex PR NPT1 DD (Conduit thread) Cable gland M 20 x 1.5 - exception: Sensing head Polytron SE Ex PR NPT1 DD (comes without cable gland) Ambient temperature SE Ex PR M1/2 DD: minimum temperature: -50 C maximum temperature: T4: 85 C, T5: 55 C, T6: 40 C SE Ex PR M3 DD: minimum temperature: -50 C maximum temperature: T4: 65 C, T5: 55 C, T6: 40 C SE Ex PR NPT1 DD: minimum temperature: -40 C maximum temperature: T4: 60 C, T5: 55 C, T6: 40 C Housings SE Ex PR M1/2/3 DD: IP 66, glass fiber reinforced Polyester (GRP) SE Ex PR NPT1 DD: IP 66, aluminum Dimensions (w x h x d) SE Ex PR M1 DD: small standard housing 80 x 130 x 56 mm incl. sensor and cable gland, 0.5 kg and weight SE Ex PR M2 DD: midsize standard housing 136 x 107 x 56 mm incl. sensor and cable gland, 0.6 kg SE Ex PR M3 DD: big GRP plastic housing 147 x 154 x 75 mm incl. sensor and cable gland, 1.2 kg SE Ex PR NPT1 DD: flameproof metal housing 101 x 142 x 75 mm incl. Sensor, 0.7 kg Explosion protection acc. to SE Ex PR M1/2/3 DD: II 2G Ex de IIC T6/T5/T4 Gb II 2D Ex td A21 IP 6x T130 C EU-directive 94/9/EC SE Ex PR NPT1 DD: II 2G Ex d IIC T6/T5/T4 Gb II 2D Ex td A21 IP 6x T130 C (Atex 95) EC-Type examination certificate BVS 10 ATEX E 060 X Explosion protection acc. to SE Ex PR M1/2/3 DD: Ex de IIC T6/T5/T4 Gb Ex td A21 IP 6x T130 C IECEx IECEx Certificate of Conformity BVS 10.0045X Polytron SE Ex HT M DD Full scale deflection Combined with a suitable controller - 100 % of the Lower Explosion Limit (LEL) Sensor current 240... 270 ma (preferably 255 ma) constant current produced by a suitable controller, approx. 1 W Response time (25 C) t 50 4 s, t90 8 s (methane) t 50 4 s, t90 9 s (propane) Measuring function (94/9/EC) Measuring function for explosion protection acc. to EN 60079-29-1 for the a.m. gases and vapors Measuring cable screened 3-core cable, core cross sections 0.5... 1.5 mm 2 outer diameter 7... 12 mm, sufficiently temperature resistant Cable gland M 20 x 1.5 Ambient temperature minimum temperature: -50 C, maximum temperature: T3: 150 C T4: 85 C, T5: 55 C, T6: 40 C Housing IP 66, galvanized cast iron housing Dimensions (w x h x d) and weight 150 x 152 x 85 mm incl. sensor and cable gland, 2.6 kg Explosion protection acc. to DrägerSensor HT M DD: DEMKO 09 ATEX 0924202X II 2G Ex d IIC T3 II 2D Ex td A21 IP 6x T195 C EU-directive 94/9/EC (Atex 95) Housing: SIRA 06 ATEX 3153 II 2G Ex e II T3 II 2D Ex td A21 IP 66 Cable gland: SIRA 01 ATEX 1272X II 2G Ex e II II 2D Ex td A21 IP 66 continue page 05

05 DRÄGER POLYTRON SE EX FIXED GAS DETECTOR TECHNICAL DATA SENSING HEADS Polytron SE Ex LC... DD Full scale deflection Combined with a suitable controller - 10 % of the Lower Explosion Limit (LEL) Sensor current 276 ma constant current produced by a suitable controller, approx. 1 W Response time (25 C) t 50 < 6 s, t 90 < 20 s (methane) Measuring cable screened 3-core cable, core cross sections 0.5... 1.5 mm 2 outer diameter 7... 12 mm - exception: Sensing head Polytron SE Ex LC NPT1 DD (Conduit thread) Cable gland M 20 x 1.5 - exception: Sensing head Polytron SE Ex LC NPT1 DD (comes without cable gland) Ambient condition maximum temperature: SE Ex LC M1/2 DD: T4: 85 C, T5: 50 C, T6: 40 C SE Ex LC M3 DD: T4: 65 C, T5: 50 C, T6: 40 C SE Ex LC NPT1 DD: T4: 60 C, T5: 50 C, T6: 40 C minimum temperature: -40 C atmospheric pressure: 800... 1100 mbar relative humidity: 5... 95 %, non-condensing Housings SE Ex LC M1/2/3 DD: IP 66, glass fiber reinforced Polyester (GRP) SE Ex LC NPT1 DD: IP 66, aluminum Dimensions (w x h x d) and weight SE Ex LC M1 DD: small standard housing 80 x 130 x 56 mm incl. sensor and cable gland, 0.6 kg SE Ex LC M2 DD: midsize standard housing 136 x 107 x 56 mm incl. sensor and cable gland, 0.7 kg SE Ex LC M3 DD: big GRP plastic housing 147 x 154 x 75 mm incl. sensor and cable gland, 1.3 kg SE Ex LC NPT1 DD: flameproof metal housing 101 x 142 x 75 mm incl. Sensor, 0.8 kg Explosion protection acc. to SE Ex LC M1/2/3 DD: II 2G Ex de IIC T6/T5/T4 Gb II 2D Ex td A21 IP 6x T130 C EU-directive 94/9/EC (Atex 95) SE Ex LC NPT1 DD: II 2G Ex d IIC T6/T5/T4 Gb II 2D Ex td A21 IP 6x T130 C EC-Type examination certificate BVS 10 ATEX E 060 X Explosion protection acc. to SE Ex LC M1/2/3 DD: Ex de IIC T4/T5/T6 Gb IP 6x T85/T100/T135 C IECEx IECEx Certificate of Conformity BVS 10.0045X SENSORS Type Catalytic bead sensor for range 0... 100 %LEL Explosion protection acc. to DrägerSensor PR M DD: II 2G Ex d IIC T4/T5/T6 II 2D Ex td A21 IP6X T130 C EU-directive 94/9/EC (Atex 95) DrägerSensor PR NPT DD: II 2G Ex d IIC T4/T5/T6 II 2D Ex td A21 IP6X T130 C DrägerSensor HT M DD: II 2G Ex d IIC T3/T4/T5/T6 II 2D Ex td A21 IP6X T130/T195 C EC-Type examination certificate DEMKO 09 ATEX 0924202X Explosion protection acc. to DrägerSensor PR M DD: Ex d IIC T6/T5/T4 Ex td A21 IP6x T130 C IECEx DrägerSensor PR NPT DD: Ex d IIC T6/T5/T4 Ex td A21 IP6x T130 C DrägerSensor HT M DD: Ex d IIC T6/T5/T4/T3 Ex td A21 IP6x T130/T195 C IECEx Certificate of Conformity UL 09.0006X Type Catalytic bead sensor for range 0... 10 %LEL Explosion protection acc. to Ex-Sensor LC M: II 2G Ex de IIC T6/T5/T4 Gb II 2D Ex t IIIC T80/T95/T130 C Db EU-directive 94/9/EC (Atex 95) Ex-Sensor LC NPT: II 2G Ex d IIC T6/T5/T4 Gb II 2D Ex t IIIC T80/T95/T130 C Db EC-Type examination certificate DMT 02 ATEX E 188 X, 2nd Supplement Explosion protection acc. to Ex-Sensor LC M: Ex de IIC T6/T5/T4 Gb Ex t IIIC T80/T95/T130 C Db IP 6X IECEx Ex-Sensor LC NPT: Ex d IIC T6/T5/T4 Gb Ex t IIIC T80/T95/T130 C Db IP 6X IECEx Certificate of Conformity BVS 10.0012X

ORDER INFORMATION Dräger Polytron SE Ex PR M1 DD, small standard housing, 0... 100 %LEL 68 12 711 Dräger Polytron SE Ex PR M2 DD, midsize standard housing, 0... 100 %LEL 68 12 710 Dräger Polytron SE Ex PR M3 DD, big GRP plastic housing, 0... 100 %LEL 68 12 718 Dräger Polytron SE Ex PR NPT1 DD, flame-proof metal housing, 0... 100 %LEL 68 12 800 Dräger Polytron SE Ex LC M1 DD, small standard housing, 0... 10 %LEL 68 12 722 Dräger Polytron SE Ex LC M2 DD, midsize standard housing, 0... 10 %LEL 68 12 721 Dräger Polytron SE Ex LC M3 DD, big GRP plastic housing, 0... 10 %LEL 68 12 719 Dräger Polytron SE Ex LC NPT1 DD, flame-proof metal housing, 0... 10 %LEL 68 12 801 Dräger Polytron SE Ex HT M DD, high temperature version, 0... 100 %LEL 68 12 720 DrägerSensor PR M DD 68 12 220 DrägerSensor PR NPT DD 68 12 380 DrägerSensor HT M DD 68 12 390 Ex-Sensor LC M 68 10 350 Ex-Sensor LC NPT 68 10 675 Dust filter for DrägerSensor PR M DD and PR NPT DD (PE-discs, 10 pcs.) 68 10 537 Calibration adapter (PE, max. operation temperature 70 C) 68 06 978 Process adapter (stainless steel, with locking nut M30 x 1,5) for DrägerSensor PR M DD, PR NPT DD and HT M DD 68 12 470 Process adapter (stainless steel, with locking nut M36 x 1,5) for Ex-Sensor LC M and LC NPT 68 12 465 90 46 142 12.10-1 Marketing Communications LE PR LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2010 Drägerwerk AG & Co. KGaA HEADQUARTERS Dräger Safety AG & Co. KGaA Revalstrasse 1 23560 Lübeck, Germany www.draeger.com SYSTEM CENTERS P. R. CHINA Beijing Fortune Draeger Safety Equipment Co., Ltd. A22 Yu An Rd, B Area, Tianzhu Airport Industrial Zone, Shunyi District, Beijing 101300 Tel +861080498000 Fax +86 10 80 49 80 05 GERMANY Dräger Safety AG & Co. KGaA Revalstrasse 1, 23560 Lübeck Tel +49 451 882-2794 Fax +49 451 882-4991 FRANCE Dräger Safety France SAS 3c route de la Fédération, BP 80141 67025 Strasbourg Cedex 1 Tel +33388405929 Fax+33388407667 SINGAPORE Draeger Safety Asia Pte Ltd 67 Ayer Rajah Crescent #06-03 Singapore 139950 Tel +65 68 72 92 88 Fax +65 65 12 19 08 UNITED KINGDOM Draeger Safety UK Ltd. Blyth Riverside Business Park Blyth, Northumberland NE24 4RG Tel +44 1670 352 891 Fax +44 1670 544 475 USA Draeger Safety, Inc. 505 Julie Rivers, Suite 150 Sugar Land, TX 77478 Tel +1 281 498 1082 Fax +1 281 498 5190