Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements
|
|
|
- Rosanna Jacobs
- 9 years ago
- Views:
Transcription
1 Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements Date of issue 11/13
2 Contents: Page 1. Wanner International and the ATEX Directive 94/9/EC 4 2. Operating Conditions 5 3. Drive Motors 5 4. a. Oil Level Monitor Unit - Category 2 Zone 1 6 b. Oil Level sight Bowl - Category 3 Zone 2 5. a) Markings of Conformity - Category 2 Zone 1 7 b) Markings of Conformity - Category 3 Zone 2 6. Earthing / Grounding 8 7. Pumpable Materials 9 8. Maintenance General notes 10 - Appendix 1 Copy of Certificate 11 - Appendix 2 Max pressure values all models 13 - Appendix 3 Manufacturers' approach 14 - Appendix 4 Schematic of oil level monitoring unit 15 - Appendix 5 Circuit diagrams (Oil level monitoring units) 16 - Appendix 6 Filling oil reservoir bowl 17 - Appendix 7 Portable Appliance Tester 18 - Appendix 8 Oil Level sight Bowl 19 2
3 1. Wanner International and the ATEX Directive 94/9/EC ATEX Directive 94/9/EC is a directive adopted by the European Union (EU) to harmonise the technical and legal requirements in the Member States for products intended for use in potentially explosive atmospheres. The Directive covers electrical and non-electrical equipment and became mandatory in July 2003 when adopted by the EU. The Directives are known as ATEX from the French - ATmospheres EXplosibles. Wanner International Ltd has worked with an outside specialist agency called Intertek ETL SEMKO in order to obtain ATEX Certification for Hydra-Cell pumps carrying out a comprehensive risk assessment and compiling the Technical File. Intertek ETL SEMKO is accredited by UKAS (the UK Accreditation Service) and authorised to carry out product safety testing and Certification of equipment under European Directives such as ATEX. See appendix 1 Type Examination Certificate. Hydra-Cell pumps are approved for use in ATEX environments - Category 2 zone 1- when installed with an oil level monitor unit or, if the pumped liquid is deemed to be inert or non-hazardous a flow meter can be employed to monitor the flow rate of the pump (see appendix 4a). CE MARKING Due to the changes made to the Machinery Directive 2006/42/EC all Hydra-Cell pumps are supplied with the CE mark on the pump manufacturers label. Certificate Number: ITS04ATEX Category 2 Zone 1 Hydra-Cell ATEX Certification covers the supply from Wanner International of bare shaft pumps only and not complete pump and electric motor sets. 3
4 2. Operating Conditions The normal operating environment is an indoor or outdoor above ground industrial environment in which flammable dust could be present. The intended external ambient operating temperature range is (minus) -10ºC to 40ºC. The intended internal operating temperature range is (minus) -10ºC to 90ºC. This is the maximum temperature range for Hydra-Cell pumps with ATEX. Certain diaphragm materials have operating limits within this temperature range. Contact Wanner International for more information and assistance. Wanner International has obtained Type Certification, for conditions outside the pump as follows:- CE Ex II 2G & D outside T4 amb (max process temperature 90 C) Group II (Zone 1), Category 2 G (gasses) & D (dust) T4 135 C (auto ignition temperature) By designing equipment suitable for use in Category 2 Zone 1 areas, operation in Category 3 Zone 2 area is also permitted. Category 3 Zone 2 only - Where the end-user will take responsibility to ensure oil is always present in the pump hydraulic-end, then a simple 'oil level sight bowl' can be fitted (see appendix 8). The user must never start or continue running the pump when oil is not visible. The pump is not intended to pump dusts but is intended for use in dust hazardous atmospheres. 3. Drive Motors Hydra-Cell ATEX Certification covers the supply from Wanner International of bare shaft pumps only and not complete pump and electric motor sets. The supplier of the drive motor and motor control system must provide over current and short circuit protection that is capable of shutting down the pump before the motor produces more than 85% of the input power limit of the hydraulic-end. The input power limit can be calculated using the Hydra-Cell standard power requirements formula (see product specification sheets on website) at maximum speed and pressure for any given pump (see appendix 2). This is necessary to ensure that the bearings are operating with a 25% safety margin, satisfying the explosion safety design concept described in clause in the Technical File (see appendix 3). 4
5 4a. Oil Level Monitor Unit - Category 2 Zone 1 For ATEX compliant installations, the pumps must carry appropriate markings of conformity. The certification is based on the principle that a Hydra-Cell pump does not create a source of ignition while the lubricating liquid is present in the drive end of the pump. ESTABLISHING THE REQUIRED PROTECTION LEVEL If the liquid to be pumped is flammable and therefore deemed hazardous, the monitoring oil bowl must be employed. When pumping non-flammable liquids, it must be defined as either hazardous or non-hazardous as part of the end users risk assessment. If a liquid is defined as hazardous as part of that risk assessment due to it being corrosive or toxic, the monitoring oil bowl must be employed. If the pumped liquid has been assessed to be as non-hazardous, the oil monitoring bowl is not required. Zone (Outside of Material being pumped Measures required the pump) 1 2 Flammable Non-flammble but toxic / corrosive Non-hazardous Flammable Non-flammable but Toxic / corrosive Non-hazardous Monitoring Oil bowl Oil level site bowl and flow meter / motor power monitor Oil level site bowl Oil level site bowl Oil level site bowl PUMPING NON-HAZARDOUS LIQUIDS If the pumped liquid is regarded as nonhazardous or inert but the pump is to be installed in an ATEX defined area (Zone 1), the working condition of the pump can be safely monitored using a flow meter to monitor the flow rate of the pump or a motor power monitor to detect a drop load in the motor. The flow from the pump or load on the motor must be continually monitored and give the operator a signal if the flow rate of the pump or the required motor power drops more than 10% below the expected value. Both these methods of monitoring will effectively detect a drop in hydraulic power generated by the pump. An oil sight bowl will be supplied and must be fitted to facilitate a visual check that the oil is present and monitor its condition. PUMPING HAZARDOUS LIQUIDS For pumping liquids that are regarded as hazardous, whether they are flammable, toxic or corrosive, an oil level monitor must be used to continually monitor the oil level in the pump. An ATEX approved Intrinsically Safe (IS) oil level monitoring device is available from Wanner International. The Wanner 'Oil Level Monitor' or Protective System is mentioned and included in the ATEX Type Certification (See appendix 1).This Type Certification allows us to offer our 'Protective System' with every Hydra-Cell ATEX pump without the need for additional certification. 5
6 ELECTROSTATIC DISCHARGE The oil level monitor has a top and bottom support plate made of Aluminium and a clear Acrylic sight bowl. Reference is therefore made to an extract from EN :2001 (E) Section in order to verify that the exposed area of acrylic is within the recommendations for non-conductive parts. ATEX - INTRINSICALLY SAFE (IS) CIRCUIT The two Low-level switches must be wired independently to their own individual IS Barrier circuit; whilst the two High-Level switches can be wired in series (or parallel) to a common IS Barrier circuit. The Low-level switches are the most critical to ensure liquid is always present in the pump housing. Accordingly, ATEX Regulations demand that all 'critical sensors' are duplicated; hence two switches must be employed. However, the High-level switches are not so critical and simply prevent over fill and spillage of liquid from the oil reservoir bowl, therefore one switch is effectively redundant and can be used as a spare in the event of a switch failure (see appendix 5 Approved circuit drawing ). All switches should operate from a normally closed position - LL - low level opens when oil level decreases. LH - high level opens when oil level rises All switches should operate from a normally closed position - Float level switch specs - Voltage Free switches held in place by a 'Noble metal' magnet (normally closed position). Type Reed switches 30VA rating SPST with Rhodium contacts, SS-316 stem. No current is required to operate switch. When magnet moves away (due to oil level change) switch will open indicating a fault. 4b. Oil Level Sight Bowl - Category 3 Zone 2 This category covers areas where an explosive atmosphere is less likely to occur and does not demand that an automatically actuated protective system be installed. Accordingly, a simple 'oil level sight bowl' can be fitted (see appendix 8). In this case the end-user must take responsibility to ensure oil is always present in the pump hydraulic-end by physically monitoring the level in the sight bowl. ELECTROSTATIC DISCHARGE The 'oil level sight bowl' has a top and bottom support plate made of Aluminium and a clear Acrylic sight bowl. Reference is therefore made to an extract from EN :2001 (E) Section in order to verify that the exposed area of acrylic is within the recommendations for non-conductive parts. 6
7 5a. Markings of Conformity - Category 2 Zone 1 All ATEX nameplates are fixed via pop rivets to the main pump housing. Material is stainless steel plate with markings clearly engraved. The pump's unique serial number and model configuration is stamped onto the standard nameplate during manufacture before supply. ATEX nameplates contain following markings: Ex II 2G D OUTSIDE EEx k ia IIB T4 130 C -10 / 40 C, II 3G INSIDE Max PROCESS 90 C CERT.No. ITS04ATEX11919 Depending on the Hydra-Cell pump Series supplied then a particular design of nameplate is fitted (see following drawing references). WI-ATEX-1035 WI-ATEX-2021 WI-ATEX / 4 / 10 / 12 / 15 / 17 / 25 / 35 / T80 series 20 series markings 20 series support block 5b. Markings of Conformity - Category 3 Zone 2 All ATEX nameplates are fixed via pop rivets to the main pump housing. Material is stainless steel plate with markings clearly engraved. The pump's unique serial number and model configuration is stamped onto the standard nameplate during manufacture before supply. ATEX nameplates contain following markings: Ex II 3 GD k IIC T4 130 C OUTSIDE, II 3 G k IIC T4 INSIDE T amb -10/+40 C, max. Process Temp. 90 C Depending on the Hydra-Cell pump Series supplied then a particular design of nameplate is fitted (see following drawing references). WI-ATEX-1036 WI-ATEX-2021Z2 WI-ATEX / 4 / 10 / 12 / 15 / 17 / 25 / 35 / T80 series 20 series markings 20 series support block 7
8 6. Earthing / Grounding An earth stud is fitted to each Hydra-Cell ATEX certified pump and should be connected to ground during installation. Every Hydra-Cell ATEX certified pump, with Oil Level Monitor or Oil Level Sight Bowl mounted in position, is tested for earth continuity before despatch to the customer. EARTH CONTINUITY CHECKS & PROCEDURE Earth Continuity Device used: Portable Appliance Tester - PAT 5001; Equipment Class 1 Ser. Nr Specifications: mains 230v 50Hz max power 250 VA Fuse 2 amps Checking procedure. 1. Cable 'A' is clipped to the top of the oil bowl metal casing 2. Cable 'B' is connected to the earth stud, that is screwed into the main body of the pump. 3. These cables are also plugged into the PAT device (see appendix 7). 4. The 'earth bond' is then measured on the deflection meter, when the red earth bond button is depressed on the PAT device (see appendix 7.1). 5. Values of below 0.1 ohms can be expected and as such are acceptable. The actual value should be recorded against each pumps unique Serial No. 8
9 7. Pumpable Materials Preventing the formation of explosive atmospheres both within the pump and external to it is not within the control of Wanner International. It is the users that are responsible for ensuring that pumps are not allowed to pump potentially explosive atmospheres for prolonged periods or as part of the normal operation. The chemicals to be pumped are predefined by the user and outside of the control of Wanner International. However, the following is a list of material categories that are considered to be suitable for use in a Hydra-Cell pump. These pumps are designed to handle flammable liquids and other liquid chemicals. Acetone Acetate Ethanol Ethylene Methyl Ethyl Ketone Butane Turpentine Stoddard Oil Xylene Methanol White Spirit N-Hexane Gasoline Heptane Propylene Oxide Pentane Kerosene Benzene Pitch Oil Propanol Toluene Tall Oil Degassed Crude Oil Lubricating Oil Please note: Wanner International must be informed in writing if other chemicals are likely to be involved. Accordingly an 'Application Questionnaire' should be completed and returned to Wanner International with details of the process liquid. Hydrogen Peroxide, which reacts exothermically with many oils is not listed and should NOT be pumped. Mixing of corrosive and or aggressive chemicals should be avoided. Hydrogen Sulphide H 2 S reacts adversely with SS-304 and 316. Care must be taken when selecting materials from Hydra-Cell's standard options. 9
10 8. Maintenance As part of the regular maintenance procedure the following routine checks must be made. Please refer to the Hydra-Cell Installation / Service Manual and supplements, for more detailed instructions on maintenance and checking methods. 1. Wanner Oil Level Monitoring Unit - check oil level periodically. 2. Wanner Oil Level Monitoring Unit - check is functioning as intended. 3. Wanner Oil Level Sight Bowl - check oil level daily. 4. Pressure relief / by-pass valve is functioning as intended. 5. All head and casing bolts are secured (refer to torque values). 6. Check for electrical earth continuity. 7. Check the integrity of the external shaft seals and pump head O-rings. 8. Check the hydraulic-end to determine whether replacement bearings are required. 9. General Notes - Lubricating oil should be changed in accordance with guidelines stated in the pump Installation / Service manual. The type of oil recommended and the frequency of oil change will vary in accordance with the pump materials of construction, the model, the duty, speed and pressure, and liquid temperature. - Hydra-Cell Pumps are not suitable for total immersion in liquid. - Only genuine replacement parts and mechanical components must be used, because only genuine parts will have the chemical and mechanical properties that have been developed to achieve explosion safety. 10
11 Appendix 1 11
12 12
13 Appendix 2 MAX PRESSURE VALUES ALL MODELS Models Discharge Inlet (any prefix letter) Pressure Pressure 20 Series 100 bar 7 bar 70 bar max G20/F20 17 bar max non-metallic heads 3 Series bar 70 bar max X-cams 17 bar max non-metallic heads 4 Series 170 bar 34 bar 10/12 Series 70 bar 17 bar 17 bar max non-metallic heads 15/17 Series 170 bar 34 bar 25 Series 70 bar 17 bar 17 bar max non-metallic heads 35 Series 83 bar 17 bar 13
14 Appendix 3 Manufacturer's approach Wanner Hydra-Cell Industrial Pump Range for ATEX Group II Categories 2 & 3 Preliminary observations. A. Technological knowledge which can change rapidly must be taken into account as far as possible and be utilised immediately. B. For the devices referred to in articles 1 (2) the essential requirements shall apply only in so far as they are necessary for the safe and reliable functioning and operation of these devices with respect to the risk of explosion. 1. COMMON REQUIREMENTS FOR EQUIPMENT AND PROTECTIVE SYSTEMS 1.0 General requirements Principles of integrated explosion safety Equipment and protective systems intended for use in potentially explosive atmospheres must be designed from the point of view of integrated explosion safety. In this connection the manufacturer must take measures: - above all if possible, to prevent the formation of explosive atmospheres which may be produced or released by equipment and by protective systems themselves. - to prevent the ignition of explosive atmospheres, taking into account the nature of every electrical and non-electrical source of ignition. - Should an explosion nevertheless occur which could directly or indirectly endanger persons and, as the case may be, domestic animals or property to halt it immediately and/or to limit the range of explosion, flames and explosion pressures to a sufficient level for safety 14
15 Appendix 4 Cold-fill level Approximate capacities: To cold-fill level 180ml To Low cut-out 100ml To High cut-out 350ml 15
16 Appendix 5 - Category 2 Zone 1 requirements Intrinsically Safe, approved electrical connection drawing. Please note Wanner does not supply any electrical box or electrical equipment only the cables connected to the level switches. contacts normally closed Ui = 15v Ii = 300mA Pi = 1.2w IS - Intrinsically Safe Installation Diagram in accordance with EN50039 Note 1. Any single channel shunt Zener diode safety barrier, certified by an EEC approved body to (EE ia) IIC and having the following or lower output parameters:- Uo =15v Io =150mA Po = 0.56w The output current of the barrier must be limited by a resistor R such that Io = Uo/R. All barriers must have same polarity. 16
17 Appendix 6 Suggested procedure for fitting and filling oil reservoir bowl 1. Typical mean oil level in pump reservoir. 2. When fitting oil reservoir bowl, remove red oil filler cap, fill the pump housing to max. capacity and replace with oil level monitor unit WI-ATEX-LS01 or A Screw into pump body until sealed against O-ring. 3.Fill to level indicated on the oil level label. Note this is a guide only and allowance should be made for expansion and contraction of oil during operation. 17
18 Appendix 7 Appendix
19 Appendix 8 - Oil Reservoir sight bowl Category 3 zone 2 Category 2 zone 1 pumping non-hazardous liquids An oil reservoir sight bowl assembly is available for Hydra-Cell pumps from Wanner International for use in ATEX applications. This oil bowl will easily screw in to the pump where the oil fill cap is located and provides electrical conductivity to the pump. 16 oz (474 ml) volume sight bowl. A COND 19
20 WANNER INTERNATIONAL LTD. 8-9 Fleet Business Park, Sandy Lane, Church Crookham, Hampshire, UK. GU52 8BF Telephone: +44 (0) , Facsimile: +44 (0) web: WANNER PUMPS LTD. Flat A, 21/F, Chatham Commercial Building, 399 Chatham Road North, Hunghom Kowloon, HONG KONG Tel: (852) , Fax: (852) WANNER ENGINEERING, INC Chestnut Avenue, Minneapolis, MN 55403, USA. Tel: , Fax: web:
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
Inductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
HAZARDOUS AREA TECHNICAL GUIDE
Page 1 HAZARDOUS AREA TECHNICAL GUIDE The Redapt Hazardous Area Technical Guide provides an overview for the design and use of equipment used within potentially explosive atmospheres created by gases,
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
SEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
Wolflite Safety Handlamp H-251E
Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Fire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
FGM 160 ATEX EC type examination certificate
Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko
Design of intrinsically safe systems
AUTOMATION & C O N T R O L S W here intrinsically safe apparatus is interconnected by wiring, the safety of each piece of apparatus is affected by the performance of the other pieces of apparatus in the
UM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
Terminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
2 & 5-Wire Overfill Sensors
2 & 5-Wire Overfill Sensors Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon Universal 2 & 5-Wire Sensor is fully compatible with all our current Sensors and Monitors,
Operating Instructions
Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
Colima Visco and Colima Viscorol Magnetic Level Indicators
3.796.5275.200 IM-P329-02 CH Issue 1 Colima Visco and Colima Viscorol Magnetic Level Indicators Installation and Maintenance Instructions Colima Visco Colima Viscorol 1. Safety information 2. General product
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
Making sense of Intrinsic Safety and Intrinsically Safe Tools
Making sense of Intrinsic Safety and Intrinsically Safe Tools What is Intrinsically Safe? Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
Professional Series ATEX Portable Radios
Systemcom A/S [email protected] +47 900 20 366 Professional Series ATEX Portable Radios Product Launch, July 2005 Professional Series ATEX Objectives Provide our customers with best-in-class
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
Electrical Equipment in Hazardous Areas: Field Inspections
Electrical Equipment in Hazardous Areas: Field Inspections Bill Rankin Electrical Engineer / Senior Electrical Inspector Abstract Electrical equipment and installations that fall within explosive gas atmospheres
Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D
MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation
Liquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof
Operating Instructions Hand pallet trucks HU Profi. Issue 08.2000
Operating Instructions Hand pallet trucks HU Profi Issue 08.2000 Index 1 Introduction 1.1 Product description 1.2 General information on service and maintenance 1.3 Spare parts 1.4 Dimensions 2 Correct
Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB
Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.0 Oct 2010 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
CAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
In addition to the basic models, it is also possible for the units to be outfitted with add-ons.
1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS
STGE COO 48 Preliminary User Guide Official version will follow soon on: WWW.BITEQ-IGHTIG.COM TBE OF COTETS 1. Safety Instruction 2. Technical Specification 3. How To Set The Unit 4. How To Control The
Flammable and Combustible Liquids. Slide 1 (of 23)
Flammable and Combustible Liquids Slide 1 (of 23) Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids
AN9003 - A Users Guide to Intrinsic Safety
AN9003 - A Users Guide to Intrinsic Safety Reasons for selecting the Intrinsically Safe Concept 1. Why choose intrinsic safety? 1.1 Introduction Intrinsic safety (IS) is a low-energy signalling technique
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR
INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR 1. FUNCTIONAL DESCRIPTION: 2 2. APPLICATION: 2 3. ASSEMBLY: 2 4. HAZARD NOTICES: 2 5. ELECTRICAL CONNECTION: 3 6. OPTIONS: 3 7. CAUTION: 3 8. MAINTENANCE:
Model 3051 Pressure Transmitter with HART Protocol
Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH
INSTRUCTION MANUAL _ LEVEL SWITCH TOR REED SWITCH Type A B PC PP PF Magnetic level switch. Top mount directly in the tank. Up to 6 action thresholds. DESCRIPTION Level switch formed by: Housing (1) with
Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.
Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Problem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V
Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Spare Parts List M96A.24SM/B M96A.28SM/B
*16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Bypass level indicator With magnetic display Model BNA
Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
ATEX instruction APP 21-38 pumps
ATEX instruction APP 2138 pumps rosolutions.com The Danfoss APP 2138 pumps are marked for application in Group II Category 2 or Category 3 systems. II 3 G c T6 II 2 G c b T6 Example ATEX pump label This
T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V
Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar