Professional Series ATEX Portable Radios

Size: px
Start display at page:

Download "Professional Series ATEX Portable Radios"

Transcription

1 Systemcom A/S Professional Series ATEX Portable Radios Product Launch, July 2005

2 Professional Series ATEX Objectives Provide our customers with best-in-class two-way solutions Safe Reliable Effective Continue Motorola market leadership

3 New Professional Series ATEX Portables ATEX Certificate BVS 05 ATEX E 082 GP340 Ex GP380 Ex GP580 Ex GP680 Ex UHF MHz Available Now Available Now Q Available Now VHF MHz Q Q Q Q4 2005

4 Professional Series ATEX Gas Protection Highest ATEX gas protection (non-mining applications) Explanation of II 2 G EEx ib IIC T4 II 2 G Can be used in Gas Zone 1 (see note below) E Approved in accordance with European standards Ex Explosion-proof equipment ib Type of intrinsic safety protection (ib limitation of energy Zone 1&2) IIC Protection in the most explosive gas environment (incl. hydrogen) T4 Device surface temperature will not exceed 135 C Note: Gas Zone 1 - area in which under normal operation a potentially explosive atmosphere as a mixture of air and flammable gases, vapours or mists can occasionally form Definition in accordance with 1999/92/EC Directive (ATEX 137)

5 Professional Series ATEX Dust Protection ATEX dust protection Explanation of II 3 D IP5x T60 C II 3 D Can be used in Dust Zone 22 (see note below) IP5x Protection against dust deposits T60 C Maximum temperature of device surface Note: Dust Zone 22 - area in which under normal operation a potentially explosive atmosphere in the form of a cloud of inflammable air-borne dust is not normally present although may occur for just a short period Definition in accordance with 1999/92/EC Directive (ATEX 137)

6 Professional Series Benefits Trusted and proven product platform Proven quality All 11 categories MIL 810E spec IP54 sealing Unique Motorola Accelerated Life Test Smaller Lighter

7 Sophisticated Functionality Assured communication High audio quality - X-Pand voice compression Escalert Whisper mode Call Forwarding & Missed Calls List Enhanced employee safety Dedicated emergency button Emergency call functionality Lone worker operation Easy-to-use Intuitive user interface Ergonomic design

8 Man-down Protection New ATEX-approved plug-in module Part No N14 Installed and supported by Motorola Compatible with GP340,380,680 Motion sensor Alarm raised when radio has not moved for a programmable time period Man-down detector Alarm raised when radio <45º to vertical Available August 2005

9 Enhanced ATEX Battery Performance High-capacity Lithium Ion (1480mAh) NNTN5510AR Increased shift life (approx. 14 duty cycle) Lithium Ion chemistry No maintenance costs unlike NiCd or NiMH Longer lifetime - no memory or over-charge effects Longer shelf-life Approx 1 year self-discharge time

10 Additional ATEX Battery Safety Factor Unique battery mechanics helps eliminate operator error Peg on radio chassis keys into... recess in battery housing

11 Fully-tested Chargers Existing Professional Series chargers (ATEX exempt) 115V SUC (US Plug) MDHTN V SUC (Euro Plug) MDHTN V Single Unit Charger (UK Plug) MDHTN V Multi Unit Charger (US Plug) MDHTN V MUC (Euro Plug) MDHTN V MUC (UK Plug) MDHTN3005

12 ATEX-approved Carry Cases Soft leather case Keypad (GMLN1112A) Non-keypad (GMLN1113A) Heavy-duty leather case Keypad (GMLN1110A) Non-keypad (GMLN1111A) Note: use within a carry case is mandatory

13 ATEX-approved Accessories Contact Com Boneinductive Headset Ambient Sound Reception Headset Comfort Lightweight Headset 12-pin Hirose adapter Available Q Direct: GMLN1109A Hirose: ELN4638A Available Q Direct: GMLN1114A Hirose: EDN7702B Available Q Direct: GMLN1117A Hirose: ELN4640B Available Q GMLN1108A Notes: 1) No ATEX dust protection with above accessories attached 2) All accessories & radio side-plate have tamper-proof screw

14 Enhanced ATEX Remote Speaker Mic Superior protection ATEX gas protection II 2 G EEx ib IIC T4 ATEX dust protection II 3 D IP5x T60 C Exceeds IP54 sealing Advanced functionality Emergency button Volume controls Easy to operate with gloves Available Q GMMN1111A

15 Enhanced ATEX Remote Speaker Mic Excellent performance in the wet Enhanced grill design Membrane Special housing texture Mic cover Channel to drain water Improved mic membrane Improved wind-noise prevention New mic cover Optimal mic position Recessed mic Drain channel

16 ATEX Radio Frequency Power Limits Ignition limits for high-frequency sources Explosion Group IIA Ignition Limit 6W IIB 3.5W IIC 2W limit for IIC approval 2W Source: ExNB Clarification Sheet ExNB/04/160/P 11th Nov 2004

17 The Motorola ATEX Advantage SAFE Highest ATEX gas protection ATEX dust protection Man-down option board RELIABLE Fully-tested, proven platform Unique Accelerated Life Testing Improved LiION battery EFFECTIVE Superior audio quality Sophisticated functionality Value-add accessories

18 Backup Information A Beginner s Guide to ATEX

19 ATEX Intrinsic Safety Directive Overview EU directive 94/9/EG came into force July 1 st 2003 ATEX ATmospheres EXplosibles Mandatory in all EU member states and EFTA countries Replaced existing Intrinsic Safety directives Cenelec Factory Mutual (FM) Impact on Motorola lower protection class GP900/1200 & MTS2000 II 2 G EEx ib IIB T4

20 ATEX Directives Directive 94/9/EC - Specifies the Essential Health and Safety Requirements that must be met by equipment and protective systems intended to be used in potentially explosive atmospheres (flammable gases, vapours or dusts) Directive 99/92/EC use directive CENELEC (European Committee for Electrotechnical Standardization) has prepared the EN50XXX series of standards of harmonized standards EN50014:1997 Electrical apparatus for potentially explosive atmospheres - General requirements EN50020: Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i'

21 99/92/EC Zones Zone Hazard 99/92/EC Definition Device Category 0 Gas Area in which a potentially explosive atmosphere as a mixture of air and flammable 1G gases, vapours or mists is present either frequently or over a prolonged period 1 Gas Area in which under normal operation a potentially explosive atmosphere as a 2G (& 1G) mixture of air and flammable gases, vapours or mist can occasionally form 2 Gas Area in which under normal operation a potentially explosive atmosphere as a 3G (& 1G, 2G) mixture of air and flammable gases, vapours or mists is not normally present but may occur for just a short period 20 Dust Area in which a potentially explosive atmosphere in the form of a cloud of 1D flammable air-borne dust is present either constantly, over prolonged periods or frequently 21 Dust Area in which under normal operation a potentially explosive atmosphere in the form 2D (& 1D) of a cloud of flammable air-borne dust can occasionally form 22 Dust Area in which under normal operation a potentially explosive atmosphere in the form 3D (& 1D & 2D) of a cloud of flammable air-borne dust is not normally present although may occur for just a short period

22 ATEX Designation Device Group I = mining II = all other areas Atmosphere G = gas D = dust Type of ignition protection ia = power limiting (zone 0) ib = power limiting (zones 1&2) Temperature classes T1 = 450 C T2 = 300 C T3 = 200 C T4 = 135 C T5 = 100 C T6 = 85 C Max. surface temperature II 1 GD EEx ib IIC T4 T60 C IP5x Category 1 = zones 0 or 20 2 = zones 1 or 21 3 = zones 2 or 22 M1 = mining (zones 0&1) M2 = mining (zone 2) Conforms to European Ex-standards (i.e. EN50XXX) Explosion group I = methane (mining) IIA IIB IIC = most dangerous group (incl. hydrogen) IP Code 1 st numeral - dust 5 = dust deposits 6 = dust penetration 2 nd numeral - water 0 = no protection 1 = vertical water drip 2 = 15 water drip 3 = water spray 4 = water splash 5 = water jet 6 = strong water jet 7 = temporary immersion 8 = continual immersion

23 ATEX Temperature Classes Max. Temperature (higher classes cover lower classes) Gas Group T1: 450 C T2: 300 C T3: 200 C T4: 135 C T5: 100 C T6: 85 C I Methane IIA Acetone Ethyl alcohol Benzine Acetaldehyde Ethane I-amyl acetate Diesel fuel Ethyl ether Ethyl acetate n-butane Aircraft fuel Ammonia n-butyl Heating Oil alcohol Benzene n-hexane (pure) Acetic acid Carbon Monoxide Methanol Propane Toluene IIB Town Gas Ethylene (Coal Gas) IIC Hydrogen Acetylene Carbon disulphide Ethyl nitrate Protection provided by Professional Series ATEX radios

Motorola Professional Series ATEX Radios. The choice for professionals in hazardous environments - GP340 EX, GP380 EX, GP580 EX and GP680 EX

Motorola Professional Series ATEX Radios. The choice for professionals in hazardous environments - GP340 EX, GP380 EX, GP580 EX and GP680 EX Motorola Professional Series ATEX Radios The choice for professionals in hazardous environments - GP340 EX, GP380 EX, GP580 EX and GP680 EX The choice for Professionals in Hazardous Environments Whether

More information

HAZARDOUS AREA TECHNICAL GUIDE

HAZARDOUS AREA TECHNICAL GUIDE Page 1 HAZARDOUS AREA TECHNICAL GUIDE The Redapt Hazardous Area Technical Guide provides an overview for the design and use of equipment used within potentially explosive atmospheres created by gases,

More information

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Making sense of Intrinsic Safety and Intrinsically Safe Tools Making sense of Intrinsic Safety and Intrinsically Safe Tools What is Intrinsically Safe? Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified

More information

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled. Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are

More information

storm survivor by Entel HT900 Series Submersible Dependable Tough ATEX approved Intrinsically Safe, E Ex i b II C T3

storm survivor by Entel HT900 Series Submersible Dependable Tough ATEX approved Intrinsically Safe, E Ex i b II C T3 storm survivor by Entel HT900 Series ATEX approved Intrinsically Safe, E Ex i b II C T3 Submersible Dependable Tough HT900 - At the frontiers of safety Heavy duty locking accessory connector CSA640E optional

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

Basics of Explosion Protection

Basics of Explosion Protection Basics of Explosion Protection INTRODUCTION Understanding Global Explosion Protection Class and Division System Class-Zone System CENELEC Zone System IEC A INTRODUCTION Basics of Explosion Protection Basics

More information

Information. Communication for the open minded. Siemens Enterprise Communications www.siemens.com/open

Information. Communication for the open minded. Siemens Enterprise Communications www.siemens.com/open Information Cordless Telephones for HiPath Systems Alongside the system-specific HiPath telephones, Siemens offers additional cordless phones for operation with HiPath systems. These cordless phones will

More information

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments Video Systems Explosion Protected White Paper Series Imaging Challenges in Explosive Environments Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments Introduction Extraordinary

More information

GP329 PLUS AND GP339 PLUS PROFESSIONAL PORTABLE RADIOS

GP329 PLUS AND GP339 PLUS PROFESSIONAL PORTABLE RADIOS GP329 PLUS & GP339 PLUS PROFESSIONAL PORTABLE RADIOS MOTOROLA GP329 PLUS AND GP339 PLUS GP329 PLUS LONE WORKER Added security and safety for individuals who work remotely from their team. The radio enters

More information

Hazardous Area Classifications and Protections

Hazardous Area Classifications and Protections Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types

More information

Hazardous Area Classifications and Protections

Hazardous Area Classifications and Protections Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types

More information

How To Protect An Explosion

How To Protect An Explosion The basics of explosion protection preface It is a fact that gases, vapours and mists escape during the production, processing, transportation and storage of flammable substances in the chemical and petrochemical

More information

EX 2000/EX 2000 C/ GD 2000/GDP

EX 2000/EX 2000 C/ GD 2000/GDP Gas detectors EX 2000/EX 2000 C/ GD 2000/GDP 2000 Gas Discrimination (GD 2000 / GDP 2000) Explosimeters/ Catharometers Pocket size Long battery life High reliability New design for Enhanced performance

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex

More information

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES LDC-4000 COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES WWW.JBIND.COM 800.323.0811 [email protected] TABLE OF CONTENTS LDC-4000

More information

Zone Hazardous Location

Zone Hazardous Location Table of Contents Introduction............................................................. 3 Basic Requirements for an Explosion.......................................3 What is an explosion?...................................................3

More information

Instructions for Safe Use

Instructions for Safe Use Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety

More information

Dräger Polytron SE Ex Fixed Gas Detector

Dräger Polytron SE Ex Fixed Gas Detector Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement

More information

Terminal Box. Specifications TNCN

Terminal Box. Specifications TNCN Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet

More information

NEMA Enclosure Types

NEMA Enclosure Types The purpose of this document is to provide general information on the definitions of NEMA Enclosure Types to architects, engineers, installers, inspectors and other interested parties. [For more detailed

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

Fire Alarm System Accessories

Fire Alarm System Accessories Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer

More information

Information Gigaset professional Cordless Telephones for HiPath Systems

Information Gigaset professional Cordless Telephones for HiPath Systems Information Gigaset professional Cordless Telephones for HiPath Systems Alongside the system-specific HiPath telephones, it is also possible to operate cordless phones with HiPath systems. These cordless

More information

INTRODUCING THE COMMERCIAL SERIES PORTABLE RADIOS CP140, CP160 AND CP180

INTRODUCING THE COMMERCIAL SERIES PORTABLE RADIOS CP140, CP160 AND CP180 INTRODUCING THE COMMERCIAL SERIES PORTABLE RADIOS CP140, CP160 AND CP180 VALUE AND VERSATILITY IN A CLASSIC DESIGN Keep the lines of communication open with the Motorola Commercial Series Benefiting from

More information

Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements

Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements Date of issue 11/13 Contents: Page 1. Wanner International and the ATEX Directive 94/9/EC 4

More information

Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure November 2010

Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure November 2010 Industrial Automation and Drive Technologies Products and systems for use in hazardous areas Brochure November 2010 Explosion Protection Answers for industry. The hazardous area completely under control

More information

GP328 Plus / GP338 Plus. Motorola s Smallest Professional Radio

GP328 Plus / GP338 Plus. Motorola s Smallest Professional Radio GP328 Plus / GP338 Plus Motorola s Smallest Professional Radio GP328 Plus / GP338 Plus Motorola s smallest professional radio Compact, Light & Rugged Instant communication is important to many operations,

More information

Information. Siemens Enterprise Communications www.siemens-enterprise.com

Information. Siemens Enterprise Communications www.siemens-enterprise.com Information Gigaset professional and OpenStage Mobile Cordless phones for HiPath and OpenScape systems. Alongside the system-specific desktop telephones, it is also possible to operate cordless phones

More information

Safety instructions VEGADIS DIS81.CEIA/V****

Safety instructions VEGADIS DIS81.CEIA/V**** Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application

More information

OpenScape DECT mobile handsets

OpenScape DECT mobile handsets OpenScape DECT mobile handsets Cordless handsets for HiPath and OpenScape systems. In addition to the system-specific desktop telephones, cordless phones can also be operated with HiPath and OpenScape

More information

Intro INTRINSICALLY SAFE CAMERA. Gravity X. "Revolutionary image and videocapture in hazardous area" a n

Intro INTRINSICALLY SAFE CAMERA. Gravity X. Revolutionary image and videocapture in hazardous area a n Gravity X INTRINSICALLY SAFE CAMERA "Revolutionary image and videocapture in hazardous area" Dua Band Wifi High Performance High end Imaging FlipScape Rugged / Waterproof Zone 1 a n Intro Do you need a

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

99/92/EC (ATEX 137) USE

99/92/EC (ATEX 137) USE ATEX DIRECTIVE 99/92/EC (ATEX 137) USE The last few years have seen many changes to the regulations that apply to industry: Directive 94/9/EC (ATEX 95): Products. Directive 98/24/EC: Chemical Agents. Directive

More information

How To Use An Irius Pid Detector

How To Use An Irius Pid Detector SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use

More information

Information. Siemens Enterprise Communications www.siemens-enterprise.com

Information. Siemens Enterprise Communications www.siemens-enterprise.com Information Gigaset professional and OpenStage Mobile Cordless phones for HiPath and OpenScape systems. Alongside the system-specific table-top telephones, it is also possible to operate cordless phones

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

EzFlex Combustible Gas Leak Detector Model EZ40

EzFlex Combustible Gas Leak Detector Model EZ40 User's Guide EzFlex Combustible Gas Leak Detector Model EZ40 Introduction Congratulations on your purchase of the Extech EZ40 Combustible Gas Leak Detector. The EZ40 detects the presence of combustible

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

Class/Division Hazardous Location

Class/Division Hazardous Location Table of Contents Introduction............................................................. 3 Basic Requirements for an Explosion.......................................4 What is an explosion?...................................................4

More information

Article 505. 505.1 Scope. 505.2 Definitions. Article 505. Class I, Zone 0, 1, and 2 Locations. 52 Cooper Crouse-Hinds Code Digest

Article 505. 505.1 Scope. 505.2 Definitions. Article 505. Class I, Zone 0, 1, and 2 Locations. 52 Cooper Crouse-Hinds Code Digest Informational Note No. 2: In unclassified locations, identification is necessary to ensure that nonintrinsically safe wire will not be inadvertently added to existing raceways at a later date (C) Color

More information

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof

More information

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation

More information

OpenScape DECT mobile handsets

OpenScape DECT mobile handsets OpenScape DECT mobile handsets Cordless phones for HiPath and OpenScape systems. In addition to the system-specific desktop telephones, it is also possible to operate cordless phones with HiPath and OpenScape

More information

Electrical Equipment in Hazardous Areas: Field Inspections

Electrical Equipment in Hazardous Areas: Field Inspections Electrical Equipment in Hazardous Areas: Field Inspections Bill Rankin Electrical Engineer / Senior Electrical Inspector Abstract Electrical equipment and installations that fall within explosive gas atmospheres

More information

of Protecting Professionals through Innovative Lighting

of Protecting Professionals through Innovative Lighting of Protecting Professionals through Innovative Lighting TABLE OF CONTENTS Koehler Bright Star LLC is located in Hanover Township, Pennsylvania, USA and is a member of the Marmon Group/ Berkshire Hathaway

More information

Guide to enclosures for potentially explosive atmospheres

Guide to enclosures for potentially explosive atmospheres Guide to enclosures for potentially explosive atmospheres Guide to enclosures for potentially explosive atmospheres The safety of every application, in every environment, thanks to ATEX-certified steel,

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT OVERVIEW ASSESSING THE RISK RELATIONSHIP BETWEEN FIRES AND EXPLOSIONS CLASSIFYING HAZARDOUS AREAS INTO ZONES

More information

Design of intrinsically safe systems

Design of intrinsically safe systems AUTOMATION & C O N T R O L S W here intrinsically safe apparatus is interconnected by wiring, the safety of each piece of apparatus is affected by the performance of the other pieces of apparatus in the

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

Design, testing, certification, installation & maintenance

Design, testing, certification, installation & maintenance Legislation, Standards and Technology Design, testing, certification, installation & maintenance of electrical equipment in hazardous locations in India by Wolfgang Berner, Ashwini Bondale and Manikandan

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

ST-6057-2004. Explosion Protection GAS DETECTION SYSTEMS

ST-6057-2004. Explosion Protection GAS DETECTION SYSTEMS ST-6057-2004 Explosion Protection GAS DETECTION SYSTEMS 02 Explosion hazards mostly arise from flammable gases and vapours Instead of avoiding their ignition by explosion protection measures it may be

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Hazardous Areas Motors

Hazardous Areas Motors Motors Automation Energy Coatings Hazardous Areas Motors Ex d Ex de Ex na Low, Medium and High Voltage BFG range BFGC range W22XB / BFG8 range W22XC / BFGC8 range W22XM / BFGM8 range BFN range TABLE OF

More information

Lockout Specification BW Clip Maintenance-free single gas detector

Lockout Specification BW Clip Maintenance-free single gas detector Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

GAS AND FLAME DETECTION

GAS AND FLAME DETECTION GAS AND FLAME DETECTION THE NEED FOR GAS DETECTION Almost anywhere that people gather for work or leisure, indoors or out, there is a potential risk of exposure to toxic or flammable gases. Whether it

More information

ATEX Fans 08/02/2008. Data subject to change without prior notice

ATEX Fans 08/02/2008. Data subject to change without prior notice ATEX Fans Introduction 1. What is ATEX? 1 2. Zones 1 3. Groups and Categories 2 3.1. Group I 2 3.2. Group II 2 3.2.1. Group II, Category 1 2 3.2.2. Group II, Category 2 3 3.2.3. Group II, Category 3 3

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications

More information

Certain specific properties of compressed gases make them highly useful in various research activities.

Certain specific properties of compressed gases make them highly useful in various research activities. GAS CYLINDER SAFETY Introduction Certain specific properties of compressed gases make them highly useful in various research activities. These gases, however, can be dangerous if not handled in an appropriate

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air

More information

BRING NEW QUALITY TO YOUR COMMUNICATIONS. Telephone terminals from Panasonic

BRING NEW QUALITY TO YOUR COMMUNICATIONS. Telephone terminals from Panasonic BRING NEW QUALITY TO YOUR COMMUNICATIONS Telephone terminals from Panasonic HANDSETS THAT DELIVER THE WORLD-CLASS COMMUNICATIONS YOU DEMAND Exceptional audio quality and proven reliability Intuitive, stylish,

More information

Explosion Protected Electrical Apparatus in the Russian Federation

Explosion Protected Electrical Apparatus in the Russian Federation Legislation, Standards and Technology Explosion Protected Electrical Apparatus in the Russian Federation Adaptations of National Standards to International Standards, deviations and peculiarities by Vitaly

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified

More information

Hazardous location. Definitions

Hazardous location. Definitions Hazardous location Definitions hazardous location means any location, where there may be a significant risk of igniting gas, dust, mist or vapour, including the following: 1.1 For underground coal mines

More information

Vacuum and Compressor Systems for the Chemical Process Industry

Vacuum and Compressor Systems for the Chemical Process Industry Vacuum and Compressor Systems for the Chemical Process Industry Vacuum Pumps & Compressors Proven technology built from experience Gardner Denver Nash has been serving process industries such as petroleum,

More information

Wolflite Safety Handlamp H-251E

Wolflite Safety Handlamp H-251E Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63

More information

Intermec Devices for Hazardous Locations Selection Guide

Intermec Devices for Hazardous Locations Selection Guide Intermec Devices for Hazardous Locations Selection Guide How to determine which device is right for you. When you re specifying mobile solutions for workers in hazardous environments, safety is paramount.

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants Ram K. Saini, P.E. Principal Engineer, Chuck Emma, P.E. Principal Engineer, Burns and Roe Enterprises,

More information

Electric motors can pose a serious threat when they are

Electric motors can pose a serious threat when they are Back to Basics Choose the Right Electric Motors for Hazardous Locations Uriah van Amerom Zeton Inc. Risks associated with operating an electric motor in hazardous areas range from production downtime to

More information

Combustible Gas Leak Detector 720b

Combustible Gas Leak Detector 720b Combustible Gas Leak Detector 720b The Value Leader TM Contents Specifications Product Features Standard Accessories Optional Accessories General Description Operating Instructions Battery Replacement

More information

ATEX INDUSTRIAL VACUUM SOLUTIONS AND SAFETY SYSTEMS

ATEX INDUSTRIAL VACUUM SOLUTIONS AND SAFETY SYSTEMS ATEX INDUSTRIAL VACUUM SOLUTIONS AND SAFETY SYSTEMS INTRODUCTION Safety is an integral component of Nilfisk philosophy in the development of industrial vacuum cleaners, pneumatic conveyors and centralized

More information

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:

More information

Classification of Hazardous Atmospheres

Classification of Hazardous Atmospheres Classification of Hazardous s The following pages contain excerpts for your convenience. If more comprehensive information is required, consult with your Western Technology representative. HAZARDOUS LOCATION

More information

Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure April 2008

Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure April 2008 Industrial Automation and Drive Technologies Products and systems for use in hazardous areas Brochure April 2008 Explosion Protection www.siemens.com/industry The hazardous area completely under control

More information

For pricing or a quote, please contact TSM Matt Gianquinto. Phone: 860-550-4530. Email: [email protected]

For pricing or a quote, please contact TSM Matt Gianquinto. Phone: 860-550-4530. Email: mgianquinto@efji.com For pricing or a quote, please contact TSM Matt Gianquinto. Phone: 860-550-4530 Email: [email protected] EFJohnson s Viking portfolio offers products catering to mission critical communication systems.

More information

Intrinsically Safe Barrier Relays NY2 and 8501TO

Intrinsically Safe Barrier Relays NY2 and 8501TO Intrinsically Safe Barrier Relays NY2 and 8501TO Class/File 8501 CONTENTS Description.....................................................Page NY2 General Information..............................................

More information

The Ambient Air Monitoring System

The Ambient Air Monitoring System The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters

More information

HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V0-090902

HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V0-090902 Page 1 HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES Page 2 Heavy-Duty Hand Cutting Torch HCT 663: With lever-operated valve for cutting oxygen, for cutting duties involving high thermal loads on slabs,

More information

Explosion Protection Theory and Practice

Explosion Protection Theory and Practice Explosion Protection Theory and Practice explosion protection worldwide with installation examples This brochure on explosion protection is designed to help installation technicians, design engineers and

More information

Natural Gas Emergencies

Natural Gas Emergencies Natural Gas Emergencies Purpose To protect the personnel within the department, and citizens from the hazards involved in a natural gas emergency. The Incident Commander is to use his/her best judgment

More information

Maxell Complete Price List May 2016

Maxell Complete Price List May 2016 Maxell Complete Price List May 2016 Maxell Speakers Bluetooth Mini Bluetooth Speaker MXSP-BT01 SP 22 Lightweight and portable Built in Bluetooth 3.0 Call answering function and built in microphone 2W output

More information

Commander 2000 Control Panel

Commander 2000 Control Panel Commander 2000 Control Panel Interactive Technologies, Inc. File: Panels Overview Applications Features The Commander 2000 is an affordable wireless security system that is easy to install and easy to

More information

Fluke Digital Multimeters Solutions for every need

Fluke Digital Multimeters Solutions for every need Fluke Digital Multimeters Solutions for every need How to choose the best DMM for your job Choosing the right digital multimeter (DMM) requires thinking about what you ll be using it for. Evaluate your

More information

EFJohnson Price Guide January 22, 2016

EFJohnson Price Guide January 22, 2016 EFJohnson Price Guide January 22, 2016 Radio - Base Model TK-5430F2 TK-5430F3 700 / 800 MHz, 3.0 Watts Analog/P25 Conventional/P25 Phase I Trunking - Standard Key Model 700 / 800 MHz, 3.0 Watts Analog/P25

More information

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate traction BATTERIES din 50Ah/plate [h1 = 282, h2 = 305 mm length = b = 198 mm] 2 EPzS 100 L 2 Pg 190 L 100 45 6,8 5,7 3 EPzS 150 L 3 Pg 190 L 150 63 9,6 7,7 4 EPzS 200 L 4 Pg 190 L 200 81 12,4 9,9 5 EPzS

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Revolutionizing Your Way of Life

Revolutionizing Your Way of Life Revolutionizing Your Way of Life More Than a Tracker Mobile Pers extends protection to wherever you are! A Breakthrough in Medical Alarm Systems Mobile Pers is a state-of-the-art, portable and richly featured

More information

ES-CAM3A Outdoor IP Camera

ES-CAM3A Outdoor IP Camera ES-CAM3A Outdoor IP Camera www.etiger.com EN Specifications - Image sensor: 1/3 CMOS, 3.15 MP - Video resolution: 160x90, 320x180, 640x360, 1280x720 (H.264) - Digital zoom: 2x - Focal: 3.6mm, Aperture:

More information

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI) FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous

More information

distributing & controlling system solutions

distributing & controlling system solutions distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food

More information