1 Systemcom A/S Professional Series ATEX Portable Radios Product Launch, July 2005
2 Professional Series ATEX Objectives Provide our customers with best-in-class two-way solutions Safe Reliable Effective Continue Motorola market leadership
3 New Professional Series ATEX Portables ATEX Certificate BVS 05 ATEX E 082 GP340 Ex GP380 Ex GP580 Ex GP680 Ex UHF MHz Available Now Available Now Q Available Now VHF MHz Q Q Q Q4 2005
4 Professional Series ATEX Gas Protection Highest ATEX gas protection (non-mining applications) Explanation of II 2 G EEx ib IIC T4 II 2 G Can be used in Gas Zone 1 (see note below) E Approved in accordance with European standards Ex Explosion-proof equipment ib Type of intrinsic safety protection (ib limitation of energy Zone 1&2) IIC Protection in the most explosive gas environment (incl. hydrogen) T4 Device surface temperature will not exceed 135 C Note: Gas Zone 1 - area in which under normal operation a potentially explosive atmosphere as a mixture of air and flammable gases, vapours or mists can occasionally form Definition in accordance with 1999/92/EC Directive (ATEX 137)
5 Professional Series ATEX Dust Protection ATEX dust protection Explanation of II 3 D IP5x T60 C II 3 D Can be used in Dust Zone 22 (see note below) IP5x Protection against dust deposits T60 C Maximum temperature of device surface Note: Dust Zone 22 - area in which under normal operation a potentially explosive atmosphere in the form of a cloud of inflammable air-borne dust is not normally present although may occur for just a short period Definition in accordance with 1999/92/EC Directive (ATEX 137)
6 Professional Series Benefits Trusted and proven product platform Proven quality All 11 categories MIL 810E spec IP54 sealing Unique Motorola Accelerated Life Test Smaller Lighter
7 Sophisticated Functionality Assured communication High audio quality - X-Pand voice compression Escalert Whisper mode Call Forwarding & Missed Calls List Enhanced employee safety Dedicated emergency button Emergency call functionality Lone worker operation Easy-to-use Intuitive user interface Ergonomic design
8 Man-down Protection New ATEX-approved plug-in module Part No N14 Installed and supported by Motorola Compatible with GP340,380,680 Motion sensor Alarm raised when radio has not moved for a programmable time period Man-down detector Alarm raised when radio <45º to vertical Available August 2005
9 Enhanced ATEX Battery Performance High-capacity Lithium Ion (1480mAh) NNTN5510AR Increased shift life (approx. 14 duty cycle) Lithium Ion chemistry No maintenance costs unlike NiCd or NiMH Longer lifetime - no memory or over-charge effects Longer shelf-life Approx 1 year self-discharge time
10 Additional ATEX Battery Safety Factor Unique battery mechanics helps eliminate operator error Peg on radio chassis keys into... recess in battery housing
11 Fully-tested Chargers Existing Professional Series chargers (ATEX exempt) 115V SUC (US Plug) MDHTN V SUC (Euro Plug) MDHTN V Single Unit Charger (UK Plug) MDHTN V Multi Unit Charger (US Plug) MDHTN V MUC (Euro Plug) MDHTN V MUC (UK Plug) MDHTN3005
12 ATEX-approved Carry Cases Soft leather case Keypad (GMLN1112A) Non-keypad (GMLN1113A) Heavy-duty leather case Keypad (GMLN1110A) Non-keypad (GMLN1111A) Note: use within a carry case is mandatory
13 ATEX-approved Accessories Contact Com Boneinductive Headset Ambient Sound Reception Headset Comfort Lightweight Headset 12-pin Hirose adapter Available Q Direct: GMLN1109A Hirose: ELN4638A Available Q Direct: GMLN1114A Hirose: EDN7702B Available Q Direct: GMLN1117A Hirose: ELN4640B Available Q GMLN1108A Notes: 1) No ATEX dust protection with above accessories attached 2) All accessories & radio side-plate have tamper-proof screw
14 Enhanced ATEX Remote Speaker Mic Superior protection ATEX gas protection II 2 G EEx ib IIC T4 ATEX dust protection II 3 D IP5x T60 C Exceeds IP54 sealing Advanced functionality Emergency button Volume controls Easy to operate with gloves Available Q GMMN1111A
15 Enhanced ATEX Remote Speaker Mic Excellent performance in the wet Enhanced grill design Membrane Special housing texture Mic cover Channel to drain water Improved mic membrane Improved wind-noise prevention New mic cover Optimal mic position Recessed mic Drain channel
16 ATEX Radio Frequency Power Limits Ignition limits for high-frequency sources Explosion Group IIA Ignition Limit 6W IIB 3.5W IIC 2W limit for IIC approval 2W Source: ExNB Clarification Sheet ExNB/04/160/P 11th Nov 2004
17 The Motorola ATEX Advantage SAFE Highest ATEX gas protection ATEX dust protection Man-down option board RELIABLE Fully-tested, proven platform Unique Accelerated Life Testing Improved LiION battery EFFECTIVE Superior audio quality Sophisticated functionality Value-add accessories
18 Backup Information A Beginner s Guide to ATEX
19 ATEX Intrinsic Safety Directive Overview EU directive 94/9/EG came into force July 1 st 2003 ATEX ATmospheres EXplosibles Mandatory in all EU member states and EFTA countries Replaced existing Intrinsic Safety directives Cenelec Factory Mutual (FM) Impact on Motorola lower protection class GP900/1200 & MTS2000 II 2 G EEx ib IIB T4
20 ATEX Directives Directive 94/9/EC - Specifies the Essential Health and Safety Requirements that must be met by equipment and protective systems intended to be used in potentially explosive atmospheres (flammable gases, vapours or dusts) Directive 99/92/EC use directive CENELEC (European Committee for Electrotechnical Standardization) has prepared the EN50XXX series of standards of harmonized standards EN50014:1997 Electrical apparatus for potentially explosive atmospheres - General requirements EN50020: Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i'
21 99/92/EC Zones Zone Hazard 99/92/EC Definition Device Category 0 Gas Area in which a potentially explosive atmosphere as a mixture of air and flammable 1G gases, vapours or mists is present either frequently or over a prolonged period 1 Gas Area in which under normal operation a potentially explosive atmosphere as a 2G (& 1G) mixture of air and flammable gases, vapours or mist can occasionally form 2 Gas Area in which under normal operation a potentially explosive atmosphere as a 3G (& 1G, 2G) mixture of air and flammable gases, vapours or mists is not normally present but may occur for just a short period 20 Dust Area in which a potentially explosive atmosphere in the form of a cloud of 1D flammable air-borne dust is present either constantly, over prolonged periods or frequently 21 Dust Area in which under normal operation a potentially explosive atmosphere in the form 2D (& 1D) of a cloud of flammable air-borne dust can occasionally form 22 Dust Area in which under normal operation a potentially explosive atmosphere in the form 3D (& 1D & 2D) of a cloud of flammable air-borne dust is not normally present although may occur for just a short period
22 ATEX Designation Device Group I = mining II = all other areas Atmosphere G = gas D = dust Type of ignition protection ia = power limiting (zone 0) ib = power limiting (zones 1&2) Temperature classes T1 = 450 C T2 = 300 C T3 = 200 C T4 = 135 C T5 = 100 C T6 = 85 C Max. surface temperature II 1 GD EEx ib IIC T4 T60 C IP5x Category 1 = zones 0 or 20 2 = zones 1 or 21 3 = zones 2 or 22 M1 = mining (zones 0&1) M2 = mining (zone 2) Conforms to European Ex-standards (i.e. EN50XXX) Explosion group I = methane (mining) IIA IIB IIC = most dangerous group (incl. hydrogen) IP Code 1 st numeral - dust 5 = dust deposits 6 = dust penetration 2 nd numeral - water 0 = no protection 1 = vertical water drip 2 = 15 water drip 3 = water spray 4 = water splash 5 = water jet 6 = strong water jet 7 = temporary immersion 8 = continual immersion
23 ATEX Temperature Classes Max. Temperature (higher classes cover lower classes) Gas Group T1: 450 C T2: 300 C T3: 200 C T4: 135 C T5: 100 C T6: 85 C I Methane IIA Acetone Ethyl alcohol Benzine Acetaldehyde Ethane I-amyl acetate Diesel fuel Ethyl ether Ethyl acetate n-butane Aircraft fuel Ammonia n-butyl Heating Oil alcohol Benzene n-hexane (pure) Acetic acid Carbon Monoxide Methanol Propane Toluene IIB Town Gas Ethylene (Coal Gas) IIC Hydrogen Acetylene Carbon disulphide Ethyl nitrate Protection provided by Professional Series ATEX radios
Motorola Professional Series ATEX Radios. The choice for professionals in hazardous environments - GP340 EX, GP380 EX, GP580 EX and GP680 EX
Motorola Professional Series ATEX Radios The choice for professionals in hazardous environments - GP340 EX, GP380 EX, GP580 EX and GP680 EX The choice for Professionals in Hazardous Environments Whether
HAZARDOUS AREA TECHNICAL GUIDE
Page 1 HAZARDOUS AREA TECHNICAL GUIDE The Redapt Hazardous Area Technical Guide provides an overview for the design and use of equipment used within potentially explosive atmospheres created by gases,
Making sense of Intrinsic Safety and Intrinsically Safe Tools
Making sense of Intrinsic Safety and Intrinsically Safe Tools What is Intrinsically Safe? Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified
Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.
Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are
storm survivor by Entel HT900 Series Submersible Dependable Tough ATEX approved Intrinsically Safe, E Ex i b II C T3
storm survivor by Entel HT900 Series ATEX approved Intrinsically Safe, E Ex i b II C T3 Submersible Dependable Tough HT900 - At the frontiers of safety Heavy duty locking accessory connector CSA640E optional
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
Basics of Explosion Protection
Basics of Explosion Protection INTRODUCTION Understanding Global Explosion Protection Class and Division System Class-Zone System CENELEC Zone System IEC A INTRODUCTION Basics of Explosion Protection Basics
Information. Communication for the open minded. Siemens Enterprise Communications www.siemens.com/open
Information Cordless Telephones for HiPath Systems Alongside the system-specific HiPath telephones, Siemens offers additional cordless phones for operation with HiPath systems. These cordless phones will
Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments
Video Systems Explosion Protected White Paper Series Imaging Challenges in Explosive Environments Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments Introduction Extraordinary
GP329 PLUS AND GP339 PLUS PROFESSIONAL PORTABLE RADIOS
GP329 PLUS & GP339 PLUS PROFESSIONAL PORTABLE RADIOS MOTOROLA GP329 PLUS AND GP339 PLUS GP329 PLUS LONE WORKER Added security and safety for individuals who work remotely from their team. The radio enters
Hazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
Hazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
How To Protect An Explosion
The basics of explosion protection preface It is a fact that gases, vapours and mists escape during the production, processing, transportation and storage of flammable substances in the chemical and petrochemical
EX 2000/EX 2000 C/ GD 2000/GDP
Gas detectors EX 2000/EX 2000 C/ GD 2000/GDP 2000 Gas Discrimination (GD 2000 / GDP 2000) Explosimeters/ Catharometers Pocket size Long battery life High reliability New design for Enhanced performance
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES
LDC-4000 COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES WWW.JBIND.COM 800.323.0811 [email protected] TABLE OF CONTENTS LDC-4000
Zone Hazardous Location
Table of Contents Introduction............................................................. 3 Basic Requirements for an Explosion.......................................3 What is an explosion?...................................................3
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
Dräger Polytron SE Ex Fixed Gas Detector
Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement
Terminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
NEMA Enclosure Types
The purpose of this document is to provide general information on the definitions of NEMA Enclosure Types to architects, engineers, installers, inspectors and other interested parties. [For more detailed
SEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
Fire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
Information Gigaset professional Cordless Telephones for HiPath Systems
Information Gigaset professional Cordless Telephones for HiPath Systems Alongside the system-specific HiPath telephones, it is also possible to operate cordless phones with HiPath systems. These cordless
INTRODUCING THE COMMERCIAL SERIES PORTABLE RADIOS CP140, CP160 AND CP180
INTRODUCING THE COMMERCIAL SERIES PORTABLE RADIOS CP140, CP160 AND CP180 VALUE AND VERSATILITY IN A CLASSIC DESIGN Keep the lines of communication open with the Motorola Commercial Series Benefiting from
Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements
Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements Date of issue 11/13 Contents: Page 1. Wanner International and the ATEX Directive 94/9/EC 4
Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure November 2010
Industrial Automation and Drive Technologies Products and systems for use in hazardous areas Brochure November 2010 Explosion Protection Answers for industry. The hazardous area completely under control
GP328 Plus / GP338 Plus. Motorola s Smallest Professional Radio
GP328 Plus / GP338 Plus Motorola s Smallest Professional Radio GP328 Plus / GP338 Plus Motorola s smallest professional radio Compact, Light & Rugged Instant communication is important to many operations,
Information. Siemens Enterprise Communications www.siemens-enterprise.com
Information Gigaset professional and OpenStage Mobile Cordless phones for HiPath and OpenScape systems. Alongside the system-specific desktop telephones, it is also possible to operate cordless phones
Safety instructions VEGADIS DIS81.CEIA/V****
Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
OpenScape DECT mobile handsets
OpenScape DECT mobile handsets Cordless handsets for HiPath and OpenScape systems. In addition to the system-specific desktop telephones, cordless phones can also be operated with HiPath and OpenScape
Intro INTRINSICALLY SAFE CAMERA. Gravity X. "Revolutionary image and videocapture in hazardous area" a n
Gravity X INTRINSICALLY SAFE CAMERA "Revolutionary image and videocapture in hazardous area" Dua Band Wifi High Performance High end Imaging FlipScape Rugged / Waterproof Zone 1 a n Intro Do you need a
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
99/92/EC (ATEX 137) USE
ATEX DIRECTIVE 99/92/EC (ATEX 137) USE The last few years have seen many changes to the regulations that apply to industry: Directive 94/9/EC (ATEX 95): Products. Directive 98/24/EC: Chemical Agents. Directive
How To Use An Irius Pid Detector
SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use
Information. Siemens Enterprise Communications www.siemens-enterprise.com
Information Gigaset professional and OpenStage Mobile Cordless phones for HiPath and OpenScape systems. Alongside the system-specific table-top telephones, it is also possible to operate cordless phones
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
EzFlex Combustible Gas Leak Detector Model EZ40
User's Guide EzFlex Combustible Gas Leak Detector Model EZ40 Introduction Congratulations on your purchase of the Extech EZ40 Combustible Gas Leak Detector. The EZ40 detects the presence of combustible
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Class/Division Hazardous Location
Table of Contents Introduction............................................................. 3 Basic Requirements for an Explosion.......................................4 What is an explosion?...................................................4
Article 505. 505.1 Scope. 505.2 Definitions. Article 505. Class I, Zone 0, 1, and 2 Locations. 52 Cooper Crouse-Hinds Code Digest
Informational Note No. 2: In unclassified locations, identification is necessary to ensure that nonintrinsically safe wire will not be inadvertently added to existing raceways at a later date (C) Color
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof
MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D
MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation
OpenScape DECT mobile handsets
OpenScape DECT mobile handsets Cordless phones for HiPath and OpenScape systems. In addition to the system-specific desktop telephones, it is also possible to operate cordless phones with HiPath and OpenScape
Electrical Equipment in Hazardous Areas: Field Inspections
Electrical Equipment in Hazardous Areas: Field Inspections Bill Rankin Electrical Engineer / Senior Electrical Inspector Abstract Electrical equipment and installations that fall within explosive gas atmospheres
of Protecting Professionals through Innovative Lighting
of Protecting Professionals through Innovative Lighting TABLE OF CONTENTS Koehler Bright Star LLC is located in Hanover Township, Pennsylvania, USA and is a member of the Marmon Group/ Berkshire Hathaway
Guide to enclosures for potentially explosive atmospheres
Guide to enclosures for potentially explosive atmospheres Guide to enclosures for potentially explosive atmospheres The safety of every application, in every environment, thanks to ATEX-certified steel,
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT
EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT OVERVIEW ASSESSING THE RISK RELATIONSHIP BETWEEN FIRES AND EXPLOSIONS CLASSIFYING HAZARDOUS AREAS INTO ZONES
Design of intrinsically safe systems
AUTOMATION & C O N T R O L S W here intrinsically safe apparatus is interconnected by wiring, the safety of each piece of apparatus is affected by the performance of the other pieces of apparatus in the
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
Design, testing, certification, installation & maintenance
Legislation, Standards and Technology Design, testing, certification, installation & maintenance of electrical equipment in hazardous locations in India by Wolfgang Berner, Ashwini Bondale and Manikandan
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
ST-6057-2004. Explosion Protection GAS DETECTION SYSTEMS
ST-6057-2004 Explosion Protection GAS DETECTION SYSTEMS 02 Explosion hazards mostly arise from flammable gases and vapours Instead of avoiding their ignition by explosion protection measures it may be
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Hazardous Areas Motors
Motors Automation Energy Coatings Hazardous Areas Motors Ex d Ex de Ex na Low, Medium and High Voltage BFG range BFGC range W22XB / BFG8 range W22XC / BFGC8 range W22XM / BFGM8 range BFN range TABLE OF
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
GAS AND FLAME DETECTION
GAS AND FLAME DETECTION THE NEED FOR GAS DETECTION Almost anywhere that people gather for work or leisure, indoors or out, there is a potential risk of exposure to toxic or flammable gases. Whether it
ATEX Fans 08/02/2008. Data subject to change without prior notice
ATEX Fans Introduction 1. What is ATEX? 1 2. Zones 1 3. Groups and Categories 2 3.1. Group I 2 3.2. Group II 2 3.2.1. Group II, Category 1 2 3.2.2. Group II, Category 2 3 3.2.3. Group II, Category 3 3
Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
Certain specific properties of compressed gases make them highly useful in various research activities.
GAS CYLINDER SAFETY Introduction Certain specific properties of compressed gases make them highly useful in various research activities. These gases, however, can be dangerous if not handled in an appropriate
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
BRING NEW QUALITY TO YOUR COMMUNICATIONS. Telephone terminals from Panasonic
BRING NEW QUALITY TO YOUR COMMUNICATIONS Telephone terminals from Panasonic HANDSETS THAT DELIVER THE WORLD-CLASS COMMUNICATIONS YOU DEMAND Exceptional audio quality and proven reliability Intuitive, stylish,
Explosion Protected Electrical Apparatus in the Russian Federation
Legislation, Standards and Technology Explosion Protected Electrical Apparatus in the Russian Federation Adaptations of National Standards to International Standards, deviations and peculiarities by Vitaly
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
Inductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
Hazardous location. Definitions
Hazardous location Definitions hazardous location means any location, where there may be a significant risk of igniting gas, dust, mist or vapour, including the following: 1.1 For underground coal mines
Vacuum and Compressor Systems for the Chemical Process Industry
Vacuum and Compressor Systems for the Chemical Process Industry Vacuum Pumps & Compressors Proven technology built from experience Gardner Denver Nash has been serving process industries such as petroleum,
Wolflite Safety Handlamp H-251E
Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63
Intermec Devices for Hazardous Locations Selection Guide
Intermec Devices for Hazardous Locations Selection Guide How to determine which device is right for you. When you re specifying mobile solutions for workers in hazardous environments, safety is paramount.
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants
Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants Ram K. Saini, P.E. Principal Engineer, Chuck Emma, P.E. Principal Engineer, Burns and Roe Enterprises,
Electric motors can pose a serious threat when they are
Back to Basics Choose the Right Electric Motors for Hazardous Locations Uriah van Amerom Zeton Inc. Risks associated with operating an electric motor in hazardous areas range from production downtime to
Combustible Gas Leak Detector 720b
Combustible Gas Leak Detector 720b The Value Leader TM Contents Specifications Product Features Standard Accessories Optional Accessories General Description Operating Instructions Battery Replacement
ATEX INDUSTRIAL VACUUM SOLUTIONS AND SAFETY SYSTEMS
ATEX INDUSTRIAL VACUUM SOLUTIONS AND SAFETY SYSTEMS INTRODUCTION Safety is an integral component of Nilfisk philosophy in the development of industrial vacuum cleaners, pneumatic conveyors and centralized
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
Classification of Hazardous Atmospheres
Classification of Hazardous s The following pages contain excerpts for your convenience. If more comprehensive information is required, consult with your Western Technology representative. HAZARDOUS LOCATION
Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure April 2008
Industrial Automation and Drive Technologies Products and systems for use in hazardous areas Brochure April 2008 Explosion Protection www.siemens.com/industry The hazardous area completely under control
For pricing or a quote, please contact TSM Matt Gianquinto. Phone: 860-550-4530. Email: [email protected]
For pricing or a quote, please contact TSM Matt Gianquinto. Phone: 860-550-4530 Email: [email protected] EFJohnson s Viking portfolio offers products catering to mission critical communication systems.
Intrinsically Safe Barrier Relays NY2 and 8501TO
Intrinsically Safe Barrier Relays NY2 and 8501TO Class/File 8501 CONTENTS Description.....................................................Page NY2 General Information..............................................
The Ambient Air Monitoring System
The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters
HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V0-090902
Page 1 HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES Page 2 Heavy-Duty Hand Cutting Torch HCT 663: With lever-operated valve for cutting oxygen, for cutting duties involving high thermal loads on slabs,
Explosion Protection Theory and Practice
Explosion Protection Theory and Practice explosion protection worldwide with installation examples This brochure on explosion protection is designed to help installation technicians, design engineers and
Natural Gas Emergencies
Natural Gas Emergencies Purpose To protect the personnel within the department, and citizens from the hazards involved in a natural gas emergency. The Incident Commander is to use his/her best judgment
Maxell Complete Price List May 2016
Maxell Complete Price List May 2016 Maxell Speakers Bluetooth Mini Bluetooth Speaker MXSP-BT01 SP 22 Lightweight and portable Built in Bluetooth 3.0 Call answering function and built in microphone 2W output
Commander 2000 Control Panel
Commander 2000 Control Panel Interactive Technologies, Inc. File: Panels Overview Applications Features The Commander 2000 is an affordable wireless security system that is easy to install and easy to
Fluke Digital Multimeters Solutions for every need
Fluke Digital Multimeters Solutions for every need How to choose the best DMM for your job Choosing the right digital multimeter (DMM) requires thinking about what you ll be using it for. Evaluate your
EFJohnson Price Guide January 22, 2016
EFJohnson Price Guide January 22, 2016 Radio - Base Model TK-5430F2 TK-5430F3 700 / 800 MHz, 3.0 Watts Analog/P25 Conventional/P25 Phase I Trunking - Standard Key Model 700 / 800 MHz, 3.0 Watts Analog/P25
din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate
traction BATTERIES din 50Ah/plate [h1 = 282, h2 = 305 mm length = b = 198 mm] 2 EPzS 100 L 2 Pg 190 L 100 45 6,8 5,7 3 EPzS 150 L 3 Pg 190 L 150 63 9,6 7,7 4 EPzS 200 L 4 Pg 190 L 200 81 12,4 9,9 5 EPzS
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Revolutionizing Your Way of Life
Revolutionizing Your Way of Life More Than a Tracker Mobile Pers extends protection to wherever you are! A Breakthrough in Medical Alarm Systems Mobile Pers is a state-of-the-art, portable and richly featured
ES-CAM3A Outdoor IP Camera
ES-CAM3A Outdoor IP Camera www.etiger.com EN Specifications - Image sensor: 1/3 CMOS, 3.15 MP - Video resolution: 160x90, 320x180, 640x360, 1280x720 (H.264) - Digital zoom: 2x - Focal: 3.6mm, Aperture:
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
distributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food