20 years of FSI experiments in Dundee



Similar documents
EXPERIMENTAL RESEARCH ON CHARACTERISTICS OF CENTRIFUGAL PUMP NOISE IN WATER PIPE SYS- TEM

Hydraulic Transients used for Leakage Detection in Water Distribution Systems

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

INTERACTION BETWEEN MOVING VEHICLES AND RAILWAY TRACK AT HIGH SPEED

STUDY OF DAM-RESERVOIR DYNAMIC INTERACTION USING VIBRATION TESTS ON A PHYSICAL MODEL

SIESMIC SLOSHING IN CYLINDRICAL TANKS WITH FLEXIBLE BAFFLES

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

Water hammering in fire fighting installation

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

Finite Element Analysis for Acoustic Behavior of a Refrigeration Compressor

The University of Birmingham (Live System)

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Dispersion diagrams of a water-loaded cylindrical shell obtained from the structural and acoustic responses of the sensor array along the shell

Steam System Best Practices Condensate System Piping

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

SELECTION OF TRANSIENT ANALYSIS SOFTWARE FOR PIPELINE DESIGN: TOWARDS A EUROPEAN STANDARD

16. Heat Pipes in Electronics Cooling (2)

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Series 4000 Fiberglass Pipe and Fittings

Flow Assurance & Operability

Modelling and Computation of Compressible Liquid Flows with Phase Transition

Unsteady Pressure Measurements

The advantages and disadvantages of dynamic load testing and statnamic load testing

w o r k o G f E A x - p r S i t n c e Elegance and Strength BBR HiAm CONA Strand Stay Cable Damping Systems

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

CHAPTER 3 MODAL ANALYSIS OF A PRINTED CIRCUIT BOARD

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT TWIST RATIO OF TWISTED TAPE INSERTS

ADVANCED NDT TECHNIQUES FOR PLASTIC PIPELINE INSPECTION

check valve slam A methodology for predicting

Platform Technology for Computational Fluid Dynamics Supporting Design of System Products

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,

Pressure drop in pipes...

ACOUSTICS IN PUMPING SYSTEMS

Chapter 8: Flow in Pipes

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

MASTER DEGREE PROJECT

Simulation for the Collapse of WTC after Aeroplane Impact

Experiment # 3: Pipe Flow

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

FLUID FLOW Introduction General Description

TRAVELING WAVE EFFECTS ON NONLINEAR SEISMIC BEHAVIOR OF CONCRETE GRAVITY DAMS

Experimental Evaluation Of The Frost Formation

Numerical Analysis of Transient Phenomena in Electromagnetic Forming Processes

19th International North Sea Flow Measurement Workshop October 2001 Kristiansand, Norway

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Dimensional Analysis, hydraulic similitude and model investigation. Dr. Sanghamitra Kundu

GMC 2013: Piping Misalignment and Vibration Related Fatigue Failures

Department of Aerospace Engineering Indian Institute of Science Bangalore

Triple Service Valve Assembly

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Minor losses include head losses through/past hydrants, couplers, valves,

Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves

INTERNATIONAL. Technical journal for piping system integrity and efficiency

Solved with COMSOL Multiphysics 4.3

pressure inside the valve just before the final release of air. in pipeline systems resulting from 2p 1 p a m C D A o

Vibration Course Enhancement through a Dynamic MATLAB Graphic User Interface

Vibrations of a Free-Free Beam

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

DISTANCE DEGREE PROGRAM CURRICULUM NOTE:

Numerical Simulation of CPT Tip Resistance in Layered Soil

T U R B I N E G A S M E T E R

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

جامعة البلقاء التطبيقية

RESEARCH PROJECTS. For more information about our research projects please contact us at:

PHYS 101-4M, Fall 2005 Exam #3. MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

Experiment 3 Pipe Friction

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Amir Bashirzadeh Tabrizi, Nassir Gifani. TOOSSAB Consulting Engineers Company

Surge Pressure in Plumbing Pipe Materials

OUTCOME 1 STATIC FLUID SYSTEMS TUTORIAL 1 - HYDROSTATICS

Physics 1114: Unit 6 Homework: Answers

Manufacturing Equipment Modeling

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

MOLECULAR DRAG PUMPS MDP SERIES

Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2

Chapter 3.5: Fans and Blowers

MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING

bi directional loading). Prototype ten story

Understanding Pressure and Pressure Measurement

Burst Pressure Prediction of Pressure Vessel using FEA

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

1150 hp motor design, electromagnetic and thermal analysis

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

explain your reasoning

ENHANCEMENT OF HEAT TRANSFER USING WIRE COIL INSERTS WITH CHORD RIBS

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

ENS 07 Paris, France, 3-4 December 2007

Transcription:

20 years of FSI experiments in Dundee Arris S Tijsseling a, Alan E Vardy b a Eindhoven University of Technology, Department of Mathematics and Computer Science, P.O. Box 513, 5600 MB Eindhoven, The Netherlands b University of Dundee, Civil Engineering Division, Dundee DD1 4HN, United Kingdom Abstract Waterhammer with fluid-structure interaction (FSI) with or without cavitation can be a rewarding subject for academic research. This paper gives an overview of two decades of experimental work at the University of Dundee. The experiments concern impact tests on water-filled steel-pipe systems. The aim of the research has been to produce high-quality experimental data for vibrating pipe systems with strong liquid-pipe coupling. One set of new data, namely the natural frequencies of a T-shaped pipe system, is presented. These, and other published data, will be made freely available at www.win.tue.nl/fsi. Keywords: FSI, waterhammer, cavitation, pipe, impact, experiment 1

1. Introduction 1.1. Background Païdoussis' FSI encyclopaedia [1, 2] gives an exhaustive treatment of the dynamics of pipes carrying steady or harmonically perturbed flow. This subject is rich with interesting fundamental problems and solutions. Our work on waterhammer with FSI, categorised by Païdoussis under unsteady FSI phenomena, is academically less exciting, but of considerable importance in industrial piping systems. It was motivated by incidents and accidents caused by waterhammer in which displacement and failure of pipes and supports occurred. Research in this area has largely been driven by safety requirements in the nuclear and chemical industry [3, 4]. 1.2. Goal of experiments The original objective of the research was to design and build a test rig for clean and accurate experiments on vibrating pipes with strong liquid-pipe coupling. By clean, we mean the avoidance of complications encountered in conventional reservoir-pipevalve systems, such as unknown support conditions, unsteady valve behaviour, nonconstant reservoir pressure, disturbing pump vibration, de-aeration, etc. The resulting experimental results serve as benchmark data for the validation of theory and software. 1.3. A little bit of history There are no immediate plans for future experiments so this is a good time to look back. Alan Vardy initiated FSI research in Dundee. In 1984, an undergraduate student undertook preliminary tests with a water-filled pipe dropped vertically onto a steel base. 2

In 1985, David Fan took over, initially working with the vertical pipe, but subsequently conducting many experiments with pipes suspended horizontally on long steel wires. In 1989 and 1990, Arris Tijsseling of Delft University visited Dundee to carry out cavitation tests; in 1993 he moved to Dundee. Zhang Lixiang of Kunming University was visiting professor in 1994 and in 1997. In 1998, Della Leslie extended the originally planar systems to three-dimensions. Throughout, valuable technical assistance has been given by many persons, of whom Ernie Kuperus and Colin Stark deserve special thanks. 2. Overview of experimental results Figure 1 shows 7 test systems each composed of steel pipes of 60 mm outer diameter and 4 mm wall thickness. One pipe is 4.5 m long; the others are 1.3 m. The systems, suspended on wires, are closed at their ends and filled with pressurised tap water. Excitation is by the axial or lateral impact of a 5 m long, 51 mm diameter, steel rod on a closed end of the long pipe. Pressures, strains and structural velocities are measured at several positions along the pipes. Figure 1 Schematic representation of laboratory pipe systems 3

The dynamic behaviour of the systems is governed by axial and lateral waves in the pipe walls and by pressure waves in the liquid. The vertical pipe in the 3D-system gives rise to torsional waves and out-of-plane vibration. Strong liquid-pipe coupling occurs at the closed ends, at the elbow and at the tee. Weak coupling exists along the pipes due to axial-radial Poisson contraction/expansion. There is little damping in the system, except when deliberately introduced through a support or a damper. Transient cavitation occurs in cases where the initial static pressure of the liquid is sufficiently low. Transient vibration is recorded in tests of typically 30 milliseconds duration at sampling intervals of 8 microseconds. Free vibration tests are typically of 1.5 seconds duration with sampling intervals of 100 microseconds. Table 1 lists key publications presenting experimental data. All but one of these contain numerical simulations confirming (and interpreting) the measurements. Vibration Impact Configuration transient free axial lateral Cavitation single pipe [5]-[7] [8] [5]-[8] [6],[8] [7] support [9] [9] damper [10] [10] L-shaped [11] [12] [11],[12] [12] [11] T-shaped [13],[14] herein [13],[14] [14] L+T [15] * [15],* 3D-system * * * Table 1 Key publications of experimental results (* to be published) 4

3. Natural frequencies of water-filled T-shaped system The fingerprint of a structure is formed by its natural frequencies and FSI is known to change these natural frequencies [4, 8]. An accurate measurement of the natural frequencies of the basic pipe configurations, single, L-shaped and T-shaped, is therefore essential in FSI research. The natural frequencies of a single and L-shaped pipe have been published in [8] and [12], respectively. Previously unpublished natural frequencies of the T-shaped system specified in Table 2 are given here in Table 3. These have been derived from axial impact tests in which the long pipe is assumed not to vibrate laterally. A typical spectrum is shown in Figure 2. pipe lengths inner radius wall thickness Young modulus Poisson ratio mass density impact plug mass end cap masses T- junction mass 4.51 m 1.34 m 1.34 m 26.01 mm 3.945 mm 168 GPa 0.29 7985 kg/m 3 1.30 kg 0.32 kg 1.06 kg Table 2 Measured properties of T-shaped pipe system 26 115 152 233 345 381 470 478 579 687 757 796 871 925 986 Table 3 Measured natural frequencies of symmetric water-filled T-shaped pipe system 5

100 pressure (kpa) 10 1 0.1 0.01 1. 10 3 0 100 200 300 400 500 600 700 800 900 1000 frequency (Hz) Figure 2 Measured pressure spectrum 4. Conclusion This paper summarises the authors experimental research on unsteady FSI phenomena in liquid-filled pipe systems. It lists key publications and it presents one omission in published data, namely the natural frequencies of a water-filled, T-shaped pipe system. These frequencies embrace the significant influence of FSI. The resulting data have the special feature of exhibiting coupling phenomena without the complications that arise in experiments on pseudo-"real" systems, thereby making the data suitable for academic validation purposes. To facilitate its use for this purpose, much data are freely available on a web-site at the Technical University of Eindhoven, namely www.win.tue.nl/fsi. The site, initially developed in Dundee by Vardy, Leslie and Tijsseling, is now supported exclusively by Tijsseling. Contributions to the site will be welcome from any competent source. 6

Acknowledgements 20 years of FSI research in Dundee has been funded by CEGB, Delft Hydraulics, EDF, EPSRC (4x), ESDU, Flowguard Ltd, FUGRO and SurgeNet (The Surge-Net project (www.surge-net.info) is supported by funding under the European Commission s Fifth Framework Growth Programme via Thematic Network Surge-Net contract reference: G1RT-CT-2002-05069. The authors of this paper are solely responsible for the content, which does not necessarily represent the opinion of the Commission. The Commission is not responsible for any use that might be made of data herein). Since 1993, the work has been guided by more than twenty meetings of an international FSI Advisory Group chaired by Keith Austin (formerly Flowmaster Ltd) consisting of industrialists, consultants, software developers and academics. References [1] Païdoussis MP. Fluid-Structure Interactions - Slender Structures and Axial Flow, Vol. 1. Academic Press, 1998. [2] Païdoussis MP. Fluid-Structure Interactions - Slender Structures and Axial Flow, Vol. 2. Elsevier Academic Press, 2004. [3] Tijsseling AS. Fluid-structure interaction in liquid-filled pipe systems: a review. Journal of Fluids and Structures 1996; 10(2):109-146. [4] Wiggert DC, Tijsseling AS. Fluid transients and fluid-structure interaction in flexible liquid-filled piping. ASME Applied Mechanics Reviews 2001; 54(5):455-481. [5] Vardy AE, Fan D. Water hammer in a closed tube. In: Proc. of the 5 th Int. Conf. on Pressure Surges, BHRA, Hanover, Germany, September 1986, pp. 123-137. [6] Vardy AE, Fan D. Flexural waves in a closed tube. In: Proc. of the 6 th Int. Conf. on Pressure Surges, BHRA, Cambridge, UK, October 1989, pp. 43-57. 7

[7] Fan D, Tijsseling A. Fluid-structure interaction with cavitation in transient pipe flows. ASME Journal of Fluids Engineering 1992; 114(2):268-274. [8] Zhang L, Tijsseling AS, Vardy AE. FSI analysis of liquid-filled pipes. Journal of Sound and Vibration 1999; 224(1):69-99. [9] Tijsseling AS, Vardy AE. Axial modelling and testing of a pipe rack. In: Proc. of the 7 th Int. Conf. on Pressure Surges, BHR Group, Harrogate, UK, April 1996, pp. 363-383. [10] Tijsseling AS, Vardy AE. On the suppression of coupled liquid/pipe vibrations. In: Proc. of the 18 th IAHR Symposium on Hydraulic Machinery and Cavitation, Valencia, Spain, September 1996, pp. 945-954. [11] Tijsseling AS, Vardy AE, Fan D. Fluid-structure interaction and cavitation in a single-elbow pipe system. Journal of Fluids and Structures 1996; 10(4):395-420. [12] Tijsseling AS, Vaugrante P. FSI in L-shaped and T-shaped pipe systems. In: Proc. of the 10 th Int. Meeting of the IAHR Work Group on the Behaviour of Hydraulic Machinery under Steady Oscillatory Conditions, Trondheim, Norway, June 2001, Paper C3. [13] Vardy AE, Fan D, Tijsseling AS. Fluid/structure interaction in a T-piece pipe. Journal of Fluids and Structures 1996; 10(7):763-786. [14] Tijsseling AS, Vardy AE. FSI and transient cavitation tests in a T-piece pipe. In: Proc. of the 8 th Int. Conf. on Flow-Induced Vibration, FIV2004, Paris, France, July 2004, Vol. I, pp. 373-378. [15] Leslie-Milbourne DJ, Vardy AE, Tijsseling AS. Transient FSI in a pipe system with elbow and tee junction. In: Proc. of the 8 th Int. Conf. on Flow-Induced Vibration, FIV2004, Paris, France, July 2004, Vol. I, pp. 355-360. 8