There s a new problem on deck. Corrosion. And now there s a solution. Quick and easy. G VYCOR DECK PROTECTOR. Self-Adhered Flashing

G VYCOR DECK PROTECTOR. For longer lasting decks, install Grace Vycor Deck Protector. It s an easy add-on to your deck projects.

G VYCOR. Contractor s Guide. Flash it rightṭm WINDOWS, DOORS AND DETAIL AREAS. Self-Adhered Flashing

Asphalt Shingle Application Requirements

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Residential Roofing Guide

GreenGuard Housewrap Installation Guide

Shingle Installation Guide

Stormproof Your Roof. I ve done enough roof repairs to know that storm water that gets past the shingles

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Peel & Seal Self-Stick Roofing Solutions

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

Directions For Applying Malarkey Laminate Shingles

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Please read the entire document before purchasing and installing any of these products

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

Sun Windows General Information Sun New Construction Window Installation Instructions

SHINGLE APPLICATION GUIDE

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Titan Old World Spanish Tile

Self-Stick Roofing Solutions

AMERICAN GOTHIC PLAYHOUSE

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

Superform Products Ltd.

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

SECTION STANDING SEAM METAL ROOFING

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

Chapter 9: INSTALLING ROOFING

CHAPTER 7: Building Systems ROOFING SYSTEMS

Window Installation Instructions

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

SECTION PREFORMED METAL STANDING SEAM ROOFING

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

SUPER SHED. Indoor shelter for your outdoor tools.

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

METAL ROOFING INSTALLATION GUIDE

Best Barns USA Assembly Book

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

How To Repair A Boat Landing Deck With A Boat Bed

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Detached accessory structures that contain no conditioned floor area are exempt.

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

How To Build A Roof Tile Deck

Section Page Section Page

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

G Ice & Water Shield. Contractor s Guide. Where to Use it. How to Install it. Tips from the Pros.

Installation Instructions

Clad Direct Glaze Window Installation Instructions

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals Magnolia Ave. Chino, CA 91710

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Tundra Series Windows January 2016

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar

Chapter 10 - Scaffolding Systems

How to Replace Windows in Stucco-Clad Walls

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

SECTION ROOFING TILE

How to Install UnderDeck The Original.

ATLAS Roofing Products

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

How To Prevent Water Damage To A Home

DELTA Premium Moisture Management Systems for Foundations.

INSTALLATION GUIDE. americanwick.com WICK (9425)

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

Metal Roof Systems in High-Wind Regions

Retrofitting an Insulated Cold Roof

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

INSTALLATION OF A BAY WINDOW

Housewrap Errors. By Steve Easley

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

EPDM. Roofing systems

Classic Products, Inc. ClickLock Standing Seam Installation Manual

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

SECTION STANDING SEAM METAL ROOFING

PANELIZED HOME INSTALLATION GUIDELINE

Transcription:

G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield

What Self-Adhered Flashings Does Grace Offer? There are three key products offered by Grace to meet your flashing needs. G VYCOR PLUS G VYCOR DECK PROTECTOR Attach galvanized metal connectors with hot-dip galvanized (HDG) fasteners per ASTM A153 G VYCOR DECK PROTECTOR Attach galvanized metal connectors with hot-dip galvanized (HDG) fasteners per ASTM A153 G VYCOR PLUS G VYCOR PLUS Grace Vycor Deck Protector For Decks Available in 4 and 9 inch widths Grace Vycor Plus Flexible Flashing For Windows and Doors Convenient 4, 6, 9 and 12 inch widths, 25 mil thick RIPCORD featured in 6, 9 and 12 inch widths Split Release on Demand, Grace s unique, patented technology, for ease of installation. Measurement markings at 6 and 12 inch Now ICBO approved (Report ER-6141) Grace Vycor V40 Self-Adhered Flashing For Windows and Doors Available in convenient pre-cut sizes of 6, 9, 12, 18 and 36 inch 40 mil thick Now ICBO approved (Report ER-6141) What s in it for you Why Use Flashing Tapes 1-2 Where to Apply 3-4 Why Grace Vycor Deck Protector 5-6 Application Instructions for Decks Installation for Rot Prevention 7-11 Installation for Corrosion Prevention 12-16 Precautions and Limitations 17-18 Application Details (See Details in Window Section) Exterior Sliding Door with Deck 35 Exterior Door with Deck 36 Joist Hanger 37 Top of Deck Joist 38 Column/Post Base 39 Tension Tie-Downs/Sill Plate Connectors 40 Outside Corner 45 Wall-to-Wall Outside Corner 46 Inside Corner 47 Wall-to-Wall Inside Corner 48 Corner Detailing Patch Options 49-50 Technical Letters (See Technical Letters in Window Section) Technical Letter 1: Chemical Compatibility 53-54 Technical Letter 2: Exposure Guidelines 55 Technical Letter 3: Cold Temperature Applications 56 Technical Letter 4: Surface Preparation 57 Technical Letter 5: Shelf Life 58 Who to Call for Technical Assistance 58 NOTE: Deck Details are in Window Section pages 37-50 www.graceconstruction.com www.graceathome.com

Why Use Grace Flashings on Decks Why Use Self-Adhered Flashing On Your Deck? To prevent structural degradation of deck joists The most common reason for deck replacement is wood decay and rotted deck framing. Water that accumulates under the decking boards cannot dry out easily. It can remain trapped for a long time, creating perfect conditions for rot and decay. Water damage is one of the most common causes of building repairs. Not only are such repairs costly, but in many cases the damage is impossible to correct. Further, water intrusion in building structures creates a favorable environment for the development of other serious problems such as mold, dry rot and wood decay. Proper water management is the first step in controlling mold, dry rot and decay. To reduce the corrossion of connectors/fasteners in contact with ACQ, CA-B and ACZA pressure-treated wood As of January 1, 2004, CCA (chromated copper arsenate) treated wood is no longer used in residential deck construction. CCA is being replaced by ACQ (alkaline copper quaternary), CA-B (copper azole), and ACZA (ammoniacal copper zinc arsenate). Due to their high copper content, all of these preservatives are found to be much more corrosive to metal connectors (such as joist hangers) and fasteners (nails and screws) than CCA. As a result, industry experts believe that ACQ, CA-B and ACZA would significantly shorten the useful life of decks. 1 At Grace Construction Products, the proprietary formulation of our self-adhered deck flashing material provides extra protection to connectors and fasteners. 2

Where to Apply Grace Vycor Self-Adhered Flashings CRITICAL FLASHING AREAS All of the shaded areas below can benefit from the application of Grace Vycor Self-Adhered Flashings (beneath the finished siding and decking) and Grace Underlayments (like Grace Ice & Water Shield) for the roof. Consider Grace Vycor Self-Adhered Flashings for your critical non-roof flashing details (windows, doors, decks). Low Slope Area Rake Edge Flanged Windows Exterior Doors Sill Confined Rake Edge Eave Skylight Chimney Valley Eave Grace Ice & Water Shield Grace Vycor Plus Grace Vycor Deck Protector Ridge Hip Dormer Corners 3 4 Sill Plate Ledger Board Deck Joists

Why Grace Vycor Deck Protector WHY GRACE VYCOR DECK PROTECTOR? What Makes Grace Vycor Deck Protector Unique? Grace Vycor Deck Protector is a self-adhered membrane, formulated and tested to solve the problems of joist rot and deck corrosion. For Joist Rot Protection Grace Vycor Deck Protector is designed to prevent joist rot and wood decay. By covering the tops of deck joists, it creates an excellent barrier against water and moisture penetration. The product represents a fast, effective and inexpensive way to significantly extend the useful life of decks. Self-adhering membrane for fast, easy installation Prevents water infiltration at deck fasteners seals around fasteners Skid-resistant coating for foot traffic during installation Compatible with all decking materials Fast and easy to install. Just peel off the release paper and adhere it to the joist 5 For Corrrosion Protection Grace Vycor Deck Protector (patent pending) is a great solution to the corrosion problem. By installing Grace Vycor Deck Protector where the metal connectors/fasteners (such as joist hangers, nails and screws) come into contact with the pressure-treated wood (ACQ, CA-B and ACZA), the membrane creates a barrier between the copper (in the wood) and the zinc (in the metal). Grace Vycor Deck Protector represents a fast and inexpensive solution that significantly reduces corrosion rates of galvanized connectors to the historical levels of CCA wood. Grace Vycor Deck Protector extends the useful life of ACQ, CA-B and ACZA pressure-treated decks. Handy roll sizes Versatile useful for other non-roof flashing details Has measurement markings on the membrane surface to simplify the application procedure 6

Flashing Application Instructions for Decks INSTALLATION FOR ROT PREVENTION 7 Note: Only Grace Vycor Deck Protector has an anti-skid coating. Do not use Grace Vycor Plus on deck joists. In addition to the application instructions listed below, see Details VCRDET-200, 201, 300, 301, 302 and 303. Ledger Board Installation Steps 1-4 1 Step One: Locate the RIPCORD in Grace Vycor Deck Protector, splitting the release paper in half. Remove bottom half of paper only. Pre-cut the appropriate length of Grace Vycor Deck Protector. Adhere and roll out onto face of ledger board(s). Press into place. Note: Do not remove the other half of the release paper. 2 Step Two: Lay out joist hangers on ledger board and rim joist. Secure one side of the joist hanger leaving the other side slightly open to receive the joists. 3 Step Three: Remove weather-resistive barrier from sill of door opening. Secure the ledger board to the house as required. Remove top half of the release paper from membrane. Apply Grace Vycor Deck Protector to inside of door opening. Integrate weatherresistive barrier with ledger board flashing to form water-shedding laps. 8

Flashing Application Instructions for Decks INSTALLATION FOR ROT PREVENTION (continued) Note: Only Grace Vycor Deck Protector has an anti-skid coating. Do not use Grace Vycor Plus on deck joists. In addition to the application instructions listed below, see Details VCRDET-200, 201, 300, 301, 302 and 303. 4 Step Four: Apply another piece of pre-cut Grace Vycor flashing to door sill. Make relief cuts starting from corner of door sill. Make sure flashing is installed underneath weather-resistive barrier. Roll firmly into sill opening. Complete the deck frame as designed. 6 Step Six: For top of joists, pre-cut Grace Vycor Deck Protector to the required lengths using the appropriate 6 and 12 inch markings. Overlap Grace Vycor Deck Protector onto ledger board flashing and rim joists. Joist Installation Steps 5-7 Peel back the release paper. 9 5 Step Five: Cut joists to required lengths. Wrap ends of joists with Grace Vycor Deck Protector. Note: If joist is ACQ, CA-B or ACZA pressure-treated wood, ends of joists must be wrapped with Grace Vycor Deck Protector. Install the wrapped joists into hangers and fasten as required according to manufacturer s specifications. Roll firmly into place. Note: Tops of joists must be covered with Grace Vycor Deck Protector independently of type of wood used (pressure-treated or not). 10

Flashing Application Instructions for Decks INSTALLATION FOR ROT PREVENTION (continued) Note: Only Grace Vycor Deck Protector has an anti-skid coating. Do not use Grace Vycor Plus on deck joists. In addition to the application instructions listed below, see Details VCRDET-200, 201, 300, 301, 302 and 303. 7 Step Seven: Cut the membrane at every joist inside corner and adhere onto joist-end flashing. Note: For outside exterior joists ONLY, either line up the membrane at the edge OR trim/terminate membrane flush to the exposed fascia board. INSTALLATION FOR CORROSION PREVENTION Note: Only Grace Vycor Deck Protector has an anti-skid coating. Do not use Grace Vycor Plus on deck joists. In addition to the application instructions listed below, see Details VCRDET-200, 201, 300, 301, 302 and 303. Ledger Board Installation Steps 1-4 1 Step One: Locate the RIPCORD in Grace Vycor Deck Protector, splitting the release paper in half. Remove bottom half of paper only. Pre-cut the appropriate length of Grace Vycor Deck Protector. Adhere and roll out onto face of ledger board. Complete the deck. 11 Press into place. Note: Do not remove the other half of the release paper. 12

Flashing Application Instructions for Decks INSTALLATION FOR CORROSION PREVENTION (continued) Note: Only Grace Vycor Deck Protector has an anti-skid coating. Do not use Grace Vycor Plus on deck joists. In addition to the application instructions listed below, see Details VCRDET-200, 201, 300, 301, 302 and 303. 2 Step Two: Lay out joist hangers on ledger board and rim joist. Secure one side of the joist hanger leaving the other side slightly open to receive the joists. 4 Step Four: Apply pre-cut Grace Vycor flashing to door sill. Make relief cuts starting from corner of door sill. Make sure flashing is installed underneath weather-resistive barrier. 3 Step Three: Remove weather-resistive barrier from sill of door opening. Secure the ledger board to the house as required. Roll firmly into sill opening. Complete the deck frame as designed. 13 Remove top half of the release paper from membrane. Apply Grace Vycor Deck Protector to inside of door opening. Integrate weather-resistive barrier with ledger board flashing to form watershedding laps. Joist Installation Steps 5-7 5 Step Five: Cut joists to required lengths. Wrap ends of joists with Grace Vycor Deck Protector. Note: If joist is ACQ, CA-B or ACZA pressure-treated wood, ends of joists must be wrapped with Grace Vycor Deck Protector. 14 Install the wrapped joists into hangers and fasten as required according to manufacturer s specifications.

Flashing Application Instructions for Decks INSTALLATION FOR CORROSION PREVENTION (continued) Note: Only Grace Vycor Deck Protector has an anti-skid coating. Do not use Grace Vycor Plus on deck joists. In addition to the application instructions listed below, see Details VCRDET-200, 201, 300, 301, 302 and 303. 6 Step Six: For top of joists, pre-cut Grace Vycor Deck Protector to the required lengths using the appropriate 6 and 12 inch markings. Overlap Grace Vycor Deck Protector onto ledger board flashing and rim joists. 7 Step Seven: Cut the membrane at every joist inside corner and adhere onto joist-end flashing. Note: For outside exterior joists ONLY, either line up the membrane at the edge OR trim/terminate membrane flush to the exposed fascia board. Peel back the release paper. Complete the deck. 15 Roll firmly into place. Note: Tops of joists must be covered with Grace Vycor Deck Protector independently of type of wood used (pressuretreated or not). 16

Precautions and Limitations PRECAUTIONS AND LIMITATIONS Grace Vycor Self-Adhered Flashings are designed for critical non-roof flashing details. DO NOT install on the roof. Grace Vycor Plus and Grace Vycor V40 are slippery DO NOT walk on their surface. The surface of Grace Vycor Deck Protector, although treated with a skid-resistant coating, could also be slippery. Use special care and take all necessary fall protection precautions when walking on the membrane. Release liners are slippery. Remove from work area immediately after membrane application. Some solvents in certain caulking may be incompatible with the adhesive in Grace Vycor Self-Adhered Flashings. Refer to Technical Letter 1, Chemical Compatibility with Other Building Materials and Sealants, page 51. If fasteners are removed, leaving holes in the membrane, it must be patched with another piece of membrane. Consistent with good construction practices, install the membrane such that all laps shed water (following the shingle principle). The top membrane layer should go over the bottom layer. Always work from the low point to the high point. Do not leave Grace Vycor Self-Adhered Flashings permanently exposed to direct sunlight. Due to its slight asphaltic odor, DO NOT apply this product where the membrane is exposed to interior living space. Apply Grace Vycor Self-Adhered Flashings only in fair weather when the air, surface and membrane are at temperatures of -4 C (25 F) or higher. 17 Grace Vycor Self-Adhered Flashings should not be used in hot desert areas in the Southwestern United States. Grace Vycor Self-Adhered Flashings are not compatible with plasticized polyvinyl chloride (flexible PVC). Certain metal window applications with integral nail fin may have specific limitations. Contact window manufacturer for specific application instructions required when using a bituminous-based flashing. SAFETY, STORAGE AND HANDLING Grace Vycor Self-Adhered Flashing and accessory products must be handled properly. Read all product labels and Material Safety Data Sheets (MSDS) see our web site at www.graceconstruction.com for proper handling and disposal. Deliver all materials in manufacturer's unopened packages and store all materials under cover. Do not double stack palletized material. 18

End of DECKS AND DETAIL AREAS Flip book for Window, Doors and Detail Areas installation NOTE: See Deck Details in Window Section pages 27-52 NOTE: See Technical Letters in Window Section pages 53-58