1 Introduction - Advice... 2. 2 Conductor Rails... 3. 3 Track Coupler... 4. 4 Power feeds... 5. 5 Air Gap Insulation Section... 6



Similar documents
Product Overview Conductor Rails

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS

1 System module for conductor rail Tools for conductor rail Content of tool kit Standard... 6

ACTIV-8 PLUS Insulated Conductor Bar

The range of rail-mounted terminal blocks. for a perfect electrical installation.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Shunt lock function 3066

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables

Emergency lighting units EM powerled

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

Directory chapter 04

High Power Connectors for Power Supply and Power Circuits

Universal MATE-N-LOK Connectors

LIST OF CONTENTS STARTING DEVICES. Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

HARTING Ethernet Cabling 4-poles Overview

INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION.

Feed-through terminals

FABA 100 Insulated Conductor System. Mounting Instructions. Fon: +49 (2307) Fax: +49 (2307) info@vahle.de

CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley

How To Use A Power Supply On A Powerline 2.2 (Ai)

COB panel supports for multipole connectors

Aluminium Standard. Technical Data. Included in delivery

Modular I/O System Analog and Digital Interface Modules

picomax The Pluggable Connection System

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.:

Sebastian Knödler Technologie, Rosenstraße 25, D Auenwald Tel.: +49 (0) / Fax: +49 (0)

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

EPIC CIRCON M23 Series Circular Signal Connectors

Redundancy Module QUINT-DIODE/40

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

AMPSEAL* Automotive Plug Connector and Header Assembly

LOW-VOLTAGE CURRENT TRANSFORMERS

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Automation Solutions. LÜTZE LCOS empty housing for Industrial Automation

Win 7 - STIMA CLS / CMP Driver Installation Quick Guide

gastroparts WTYCZKI I KONEKTORKI Części zamienne do urządzeń: KAWA GASTROPARTS Sp. J.

IMPORTANT DOCUMENTATION DO NOT DISCARD!

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

gesis IP + Heavy Duty Class I, Zone 2

These Installation Instructions are valid for antennas in the following version:

Field bus connections Link structure CMS link structure CMS, B-design. Brochure

A good connection. International approvals.

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

400 Series - Mini USB Buccaneer

3-Component Measuring System

RAIL FREE SOLAR ROOF MOUNT

Standard Buccaneer - USB

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Quick Reference Guide Euro Style Terminal Blocks

Anderson Power Products

Installation Manual. BYD Wall-mounted AC Charging Box

Positioner. KUKA Roboter GmbH. KUKA Positioner. DKP-400 Specification. Issued: Version: Spez DKP-400 V7

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

HARTING Ethernet Cabling 8-poles Overview

UBBINK SOLAR IN-ROOF SYSTEM

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Nordson Automatic Spray Gun Support Kits

Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.

Product and functional description

Conductor Bar Manual 8-Bar

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Low Voltage Switchboards The Best Technical Solution for Your Ship

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Quick Connect Boxes Inside Gloveboxes

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Installation instruction CASAFLEX - Connecting piece DN 100

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

New XUY roller sensors

Product Information. HMC 6 Hybrid Motor Cable

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

KNX R. Rain Sensor. Installation and Adjustment

Elektromotoren und Gerätebau Barleben GmbH

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

ASSEMBLY MANUAL SE-4S35

Model CS 64 Mini-DIN Cable and Adaptor

ALBINS SEQUENTIAL SHIFTER

BNC, N, TNC Connectors

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Spring Cage Feed-Through Terminal Blocks ST

Operating Instructions

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Feed-through terminal block - SSK 110 KER-EX

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Transcription:

Contents 1 Introduction - Advice... 2 2 Conductor Rails... 3 3 Track Coupler... 4 4 Power feeds... 5 5 Air Gap Insulation Section... 6 6 Expansion joints... 7 7 Anchor Caps... 8 8 End Caps (Distance between Phases 14 mm)... 9 9 Hanger Clamps... 11 10 Current Collectors... 12 www.conductix.com translated document Page 1 of 14

1 Introduction - Advice The conductor rail 0815 PE with polarity protection PE plus features a larger contact width for the current collector head than the standard conductor rails 0815. Due to this special feature the grounding collector (PE) current collector head cannot intervene in a phase (PH) conductor rail. This solution will safely prevent accidental energizing of the phase voltage to the PE pole and the improper utilization of the PE current collector as phase current collector! This technical data sheet describes all necessary standard components for the construction of a conductor rail of program 0815 SingleFlexLine with PE plus - polarity protection for the installation in monorail systems (EMS) and similar applications. It serves as a supplement to the existing catalogs. The PE rail system of existing conductor rail systems SingleFlexLine 0815 can be refitted. All that needs to be replaced are the existing PE rails, end caps and the PE current collectors. The hanger clamps and the PH rails must not be replaced. The existing current collectors can be operated in the new PE rail, so that a gradual reconstruction of the existing current collectors can be realized. A polarity protection device should generally be provided on new installations or modernizations of EMS! www.conductix.com translated document Page 2 of 14

2 Conductor Rails PH PE PE plus (PE with polarity protection) Conductor rail for curve manufacturing Type Order Number Copper rail 100 A for collector PH, 4000 mm 081516-4x11 1.092 Copper rail 100 A for grounding collector PE; without polarity protection PE plus 4000 mm Copper rail 100 A for grounding collector PE plus ; with polarity protection PE plus 4000 mm 081516-4x12 1.092 081516-4x14 1.092 Copper rail 100 A for collector PH; 6000 mm 081516-6x11 1.640 Copper rail 100 A for grounding collector PE; without polarity protection PE plus 6000 mm Copper rail 100 A for grounding collector PE plus ; with polarity protection PE plus 6000 mm Copper rail 100 A for grounding collector PE plus ; with polarity protection 4000 mm, for manufacturing of curves with radius < 1.500 mm 081516-6x12 1.640 081516-6x14 1.640 081516-4x15 1,092 The grounding collector insulations are marked yellow-green on both sides. All technical details are according to the standard conductor rail 0815. For manufacturing of curves with small radius use special rail 081516-4x15! Rails and other components and cable cores with PE identification (yellow-green) may not be used as live components. The PE plus rail with polarity protection has an additional fixation of the insulating profile (T-profile at the insulation profile base). www.conductix.com translated document Page 3 of 14

3 Track Coupler Type Order Number Track coupler, screwable 081521 0.016 Color: Black/Usable for all rail links www.conductix.com translated document Page 4 of 14

4 Power feeds Type Order Number Power feed 1.5-2.5 mm²; with crimp type cable lug 081551-1 0.016 Power feed 4-6 mm²; with crimp type cable lug 081551-2 0.016 Power feed 5-10 mm²; with crimp type cable lug 081551-3 0.016 Color: Black/usable for all types of rails/cable outer diameter: max. Ø 6 mm www.conductix.com translated document Page 5 of 14

5 Air Gap Insulation Section The air gap insulation sections with polarity protection differ from the component without polarity protection by the adaptation of the end caps. The end caps for the grounding connector (green) have a larger contact dimension for the wide PE plus collector shoe. The phase caps have additional carbon guidance in the lateral part of the caps. Type Component Order Number Air gap insulation section PH without feed 081594-1 0.035 Air gap insulation section PH with feed 1.5-2.5 mm² PH 081594-2 0.041 Air gap insulation section PH with feed 4-6 mm² 081594-3 0.041 Air gap insulation section PE plus without feed 081594-4 0.035 Air gap insulation section PE plus with feed 1.5-2.5 mm² PE 081594-5 0.041 Air gap insulation section PE plus with feed 4-6 mm² 081594-7 0.041 www.conductix.com translated document Page 6 of 14

6 Expansion joints Expansion joint, 8 mm expansion distance Expansion joint, 20 mm expansion distance Type Number of poles Expansion distance [mm] Order Number Expansion joint PE plus with polarity protection 1 8 081561-3114 0.050 Expansion joint PH 1 081561-311 0.050 Expansion joint PE plus with polarity protection 1 081562-3114 0.050 20 Expansion joint PH 1 081562-311 0.050 Expansion joint combinations for multi-pole systems. The set includes all components for a multi-pole expansion point. Mounting position of the PE poles can be chosen freely. Type Number of poles Expansion distance [mm] Order Number Expansion joint set with PE plus 4 poles 8 mm 4 081561-3415 0.200 Expansion joint set with PE plus 6 poles 8 mm 6 8 081561-3615 0.300 Expansion joint set with PE plus 8 poles 8 mm 8 081561-3815 0.400 Expansion joint set with PE plus 4 poles 20 mm 4 081562-3415 0.200 Expansion joint set with PE plus 6 poles 20 mm 6 20 081562-3615 0.300 Expansion joint set with PE plus 8 poles 20 mm 8 081562-3815 0.400 Color: All PE components with PE plus cap components green, all other components black. www.conductix.com translated document Page 7 of 14

7 Anchor Caps The Anchor Caps are installed to the left and right of a hanger clamp and can be used for all types of rails. Type Order Number Anchor point cap 081531 0.002 www.conductix.com translated document Page 8 of 14

8 End Caps (Distance between Phases 14 mm) Type Number of Poles Power Feed Order Number End cap set complete with PE plus 6-081573-06x14x4 0.142 End cap set complete with PE plus 8-081573-08x14x4 0.160 End cap set complete with PE plus 6 1.5-2.5 mm² 081573-06x14x5 0.142 End cap set complete with PE plus 8 1.5-2.5 mm² 081573-08x14x5 0.160 End cap set complete with PE plus 6 4-6 mm² 081573-06x14x7 0.142 End cap set complete with PE plus 8 4-6 mm² 081573-08x14x7 0.160 End cap PH; individual with PH 1-08-E012-0352 0.005 End cap PH; individual with PH 1 1.5-2.5 mm² 08-E012-0353 0.005 End cap PH; individual with PH 1 4-6 mm² 08-E012-0354 0.005 www.conductix.com translated document Page 9 of 14

Type Number of Poles Power Feed Order Number End cap PE; individual with PE plus 1-081576-01x14x4 0.005 End cap PE; individual with PE plus 1 1.5-2.5 mm² 081576-01x14x5 0.005 End cap PE; individual with PE plus 1 4-6 mm² 081576-01x14x7 0.005 Color: All PE components with PE plus green. www.conductix.com translated document Page 10 of 14

9 Hanger Clamps No matter which type of rail, all standard and EMS or customer-specific screwed and quick assembly hanger clamps of the SingleFlexLine program 0815 can be used. Illustr.: Example for system-dependent hanger clamps with Leuze positioning bar code band and leaky coax cable. See also standard program or contact our system consultant. A great number von brackets is available, aligned to the respective EMS-profile, and the respective system brackets can be manufactured. www.conductix.com translated document Page 11 of 14

10 Current Collectors The PE current collectors with polarity protection PE plus differ from the standard current collector by a wider carbon shoe and a codification lug at the snap-in fixation. A notch is provided here at the PE installation position of the counterpart, the mounting plate. In case of a retrofit exchange the mounting plate or apply a notch. Due to the high number of available current collectors we have only listed the double current collectors basic types for the EMSarea here, without customer-specific special configurations. In case of need please contact us or consider the particularities based on the bidding specifications of the quotation. The PE plus current collector head cannot intervene in a PH conductor rail! The following Illustr. shows the double current collector 0815 with snap-in assembly and mounting plate (position PE coded). - Double current collector with copper graphite carbon 2 x 25 A - without connecting cable - Carbon length 50 mm - with AMP plug and socket connection - Height of carbon standard - snap-in type - Phase distance 14 mm - with PE plus polarity protection - Mounting distance base plate conductor rail bottom 80 mm (with cable guidance and cable package + 15 mm) Mounting position of the compensation spring for towing mode (for mainly towing mode). www.conductix.com translated document Page 12 of 14

Type Number of poles Order Number Current collector 0815 1P 2 x 25 A; PE plus REW 1 081509-01445 0.026 Current collector 0815 1P 2 x 25 A; PE plus TOW 1 081509-0144 0.026 Current collector* complete PE plus 2 x 25 A 1 081006-434 0.022 Current collector* complete PE plus 2 x 25 A 1 081006-134 0.022 Current collector mounting plate 1-8 See advice * Current collector head complete: carbon, insulation ** TOW = Towing Mode /REV = Reverse Mode Advice: System bracket and current collector types as well as special types. The high variance of parameters and various requirements of final customers (automotive industry and system manufacturers) as well as variously applied techniques (construction principle, installation space, etc.), offer a great number of possible combinations and special constructions, which cannot all be listed in this survey. Please contact our consulting service. We will be pleased to assist you. www.conductix.com translated document Page 13 of 14

Conductix-Wampfler GmbH Rheinstrasse 27 + 33 D-79576 Weil am Rhein - Maerkt Germany Phone: +49 (0) 7621 662-0 Fax: +49 (0) 7621 662-144 info.de@conductix.com www.conductix.com www.conductix.com translated document Page 14 of 14