Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Similar documents
Extend the Life of Existing Switchgear

Electrical Distribution Services for Mining and Metals Industries

Electrical Distribution Services from Schneider Electric

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Primary and Secondary Electrical Distribution Systems

Houston Service Center Medium Voltage Service and Aftermarket Solutions

Contents. Description. Product Selection Guide

Replacement Breakers & Retrofit Products

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

The following components are common to most cubicles; this example is an ABB HK cubicle.

Risk Mitigation of Aging Electrical Infrastructure

Medium Voltage Motor Control Assemblies

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Arc Terminator Active Arc-Resistant Switchgear

Choosing the Best Solution for Reducing Arc Energy

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Secondary Unit Substations

How To Choose A Transformer

Engineering innovation

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

MV vacuum circuit breaker Evolis. When trust guides your steps

Sample - No Commercial Use

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

SECTION 16346A METAL-CLAD MEDIUM VOLTAGE ARC RESISTANT SWITCHGEAR

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Defining the Needs of Modern Data Center Power Systems, Low Voltage Circuit Breaker Application

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety

What will MV switchgear look like in the future? by Jean-Marc Biasse

Low Voltage Switchgear

Atlanta Chapter IEEE Industry Applications Society

Applications. Remote Display Mounting Kits

MEDIUM VOLTAGE METAL CLAD SWITCHGEAR

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Enhancing Personnel Safety with Arc Resistant Equipment

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Advantages of Fixed Circuit Breaker Switchgear

The Intelligent AX1 Switchgear for Medium Voltage

Instruction Bulletin. Hand-held Test Kit. for Micrologic Series 2.0 and Above Trip Units and Compact NS Circuit Breakers Equipped with STR Trip Units

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Reliability requires consulting engineers and end users to grasp design, maintenance basics. By Reza Tajali, P.E. Square D Power Systems Engineering

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Schneider Electric Services: life-cycle solutions for electrical distribution equipment. Scopes of Work for Electrical Acceptance Testing

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Electrical Predictive and Preventative Maintenance

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

Application of Four-Pole Circuit Breakers within Data Centers

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

SERVICE-LIFE EVALUATIONS OF LOW-VOLTAGE POWER CIRCUIT BREAKERS AND MOLDED-CASE CIRCUIT BREAKERS

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

SIEMENS Transmission and Distribution

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

SECTION 16426C ARC RESISTANT DRAWOUT SWITCHGEAR (MAGNUM DS) LOW VOLTAGE

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Safety By Design. Strategies for Electrical Contractors

ABB PSPS Erich Steinmann; Generator control-2013

Eaton Automatic Transfer Switches

ABB Dedicated Products, Systems and Services for the Power Generation Industry

Technical Electrical Field Service Support. Knowledge + Experience = Power. Field Service

Alternate Methods to Short Circuit Breaker Coordination

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

Safe and reliable distribution network ABB portfolio for medium-voltage indoor applications

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

Evaluating Water-Damaged Electrical Equipment

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

Switchgear Application Issues for Mission Critical Power Systems, Part One

WINDING RESISTANCE TESTING

Medium voltage indoor circuit breakers ANSI/IEC solutions

SECTION MEDIUM VOLTAGE SWITCHGEAR

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Medium voltage VCP-W MR2 (integral racking)

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

Offshore oil platform power and control system

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Fusible Disconnect Switch

Mission Critical Data Center Systems

Permissible ambient temperature Operation Storage, transport

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT NETWORK SYSTEMS SECTION

Predictive Maintenance

Transcription:

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Spending too much time and money on equipment maintenance?

Square D Services: Your source for circuit breaker excellence. Square D Services brings together exceptional circuit breaker technology, engineering and installation expertise in complete solutions designed to minimize downtime, improve reliability and extend the life of your existing equipment. The heart of any industrial facility is its electrical distribution system In an industrial facility, nothing operates without a reliable flow of electricity. Therefore, it is critical to properly maintain the switchgear that houses overcurrent protective devices, including circuit breakers, fuses or protective relays. However, even with annual maintenance there may be instances where repairs and/or upgrades are necessary. Factors to consider include the operating environment, the availability of spare parts, reliability and the cost of ongoing maintenance. Another consideration may be the need to increase the switchgear s fault or continuous current rating or the desire to upgrade technology. As a result, facility managers are often faced with the choice of maintaining aging (or obsolete) equipment or replacing it with a new switchgear line-up to take advantage of current technology. Upgrade existing equipment Square D Services offers two additional options that are cost-effective and will expand the capabilities of your electrical system with minimal downtime. Our direct replacement and retrofill solutions utilize the upgraded technology of our Masterpact NT/NW insulated case circuit breaker for low voltage systems or the Magnum TM circuit breaker for medium voltage systems. Masterpact NT/NW Low Voltage Circuit Breakers These state-of-the-art circuit breakers provide solid state protection, reduce the potential for an arc flash event and do not require maintenance under normal operating conditions. Designs are available for most manufacturers low voltage switchboards and switchgear. Magnum Medium Voltage Circuit Breakers Each Magnum circuit breaker is manufactured using totally new components including state-of-the art vacuum or SF6 arc interruption technology. Designs are available in 5kV to15kv for most manufacturers switchgear. The benefits of utilizing the existing switchgear structure include: An economical alternative to purchasing new equipment The footprint of the equipment line-up is not affected The downtime is minimized when compared with equipment demolition and replacement Cable damage, replacement or splicing is negated Upgrades can be performed on an incremental basis to meet budget constraints or outage opportunities 3

Square D Services Modernization Solutions The right solution for your application. Two different upgrade solutions with the same end result: improved power system reliability and lower life cycle costs. Retrofill The existing switchgear cell and bus are modified to accept the new circuit breaker. Low Voltage - This solution provides a Masterpact cradle and circuit breaker, along with a new racking mechanism and primary and secondary connections in each switchgear cell. Existing cells are modified to accept the new cradle and circuit breaker, including a custom-engineered connection between the cradle and the switchgear line and load side bus. Custom designs are available for most brands of low voltage switchgear. Medium Voltage - This solution upgrades switchgear by installing a new medium voltage circuit breaker and cell into an existing line-up. Necessary modifications including an all-new racking mechanism, primary and secondary disconnects and customized connections are made to the existing cell. Available designs include: Air-Magnetic to Vacuum or SF6 Air-Blast to Vacuum or SF6 OCB Switchgear to Vacuum or SF6 Switchgear Convert Stationary Circuit Breaker to Draw-Out or Obsolete Air Circuit Breaker to Vacuum or SF6 Direct Replacement A new circuit breaker and adapter cradle fit into the existing cubicle with little-to-no cell modification, resulting in minimal downtime. Low Voltage - A standard Masterpact cradle is installed into an adapter cradle to form one assembly, which is then installed into the switchgear cubicle. (This cradle-in-cradle assembly locks into place and will remain in the switchgear cell after the initial installation.) The new Masterpact circuit breaker racks in and out of the adapter cradle. A new door is installed, however cell interlocks, the racking mechanism and the switchgear structure are not modified. Designs are available for most manufacturers switchgear. Medium Voltage The Magnum direct replacement circuit breaker will rack into the switchgear line-up and correctly interface with the existing compartment cell. The original racking mechanism, safety interlocks and the primary / secondary disconnects inherent in the original equipment design are maintained and the switchgear structure is not modified. Magnum medium voltage direct replacement circuit breakers are available for most manufacturers switchgear. 4

Low and Medium Voltage Circuit Breakers Why upgrade? When considering whether to replace or upgrade your existing switchgear, there are a number of factors to consider. One which many people never think about is conduit placement. Before After Installing new switchgear (which is usually smaller than the older/obsolete equipment it is designed to replace) requires that existing conduit above and below the equipment be moved. This time consuming and expensive process is eliminated by upgrading existing equipment with solutions from Square D Services. Improved Reliability Dash-pot style or air break interrupting devices on existing circuit breakers may have reliability issues - Many do not trip at all - Those that trip are not repeatable and may be well outside the time-current coordination parameters Aging materials reduce equipment reliability - Dielectric breakdown of insulating components - Degradation of aging mechanical parts Increased Capabilities Fault current interruption - New circuit breakers are available with higher ratings - In most cases the interruption capacity of the entire switchgear can be increased with an engineering study and a circuit breaker upgrade or replacement Arc flash limiting circuit breaker availability Trip unit accuracy and repeatability Power metering, monitoring and communication Reduced Maintenance Costs Older power circuit breakers require periodic maintenance and overhaul, which is expensive and time consuming - Lengthens outages - May require outside support Many components for existing circuit breakers are no longer supported - New parts are no longer available - The quantity and quality of used or reconditioned parts is decreasing - Prices of used or reconditioned parts are increasing Masterpact and Magnum replacement breakers for switchgear modernization are installed, tested and commissioned by factory-trained Square D Service technicians and are backed by a one-year warranty. Magnum Replacement Circuit Breaker Masterpact Replacement Circuit Breaker 5

Square D Services Modernization Solutions Masterpact NT/NW Low Voltage Direct Replacement Circuit Breakers Masterpact NT/NW power circuit breakers are designed to help protect electrical systems from damage caused by overloads, short circuits and equipment ground faults. Providing the latest in breaker technology, Masterpact circuit breakers feature high ampere interrupting and short-time current ratings, Modbus communication protocol and field-installable devices, including sensor plugs and accessories. Masterpact circuit breakers do not require maintenance under normal operating conditions. Completely modular in design, all replaceable parts can be installed with hand tools and require no critical adjustments. Additional features include: Drawout breakers with three racking positions and status indicator on cradle High ampere interrupting rating (AIR) High short-time current rating Drawout or fixed mount, 3- or 4-pole construction Integral ground-fault protection for equipment Protective relaying functions Zone-selective interlocking (ZSI), which can reduce damage in the event of a fault Field-installable accessories Meets the requirements of UL 489, UL 1066, ANSI, IEC 60947-2 and CE Mark standards Benefits include: Reduced maintenance requirements; no lubrication or adjustments required Shutters are provided, potentially reducing PPE required to remove breakers MicroLogic Trip Units: Protection and Communications For smarter breakers, a complete line of Micrologic trip units are available for use with Masterpact circuit breakers. These trip units provide advanced functionality, such as a communications interface, power metering and monitoring capabilities, which allow for integration and coordination of your electrical system. TRIP UNIT TYPES TRIP UNIT FEATURES Basic A P H Open and close the circuit breaker n n n Circuit breaker position and status: Open / Tripped / Closed / Connected / Test / Disconnected n n n Display all measurements and settings n n n View current and voltage waveforms Fine settings n n Read all logged data n n Maintenance record n n Micrologic Trip Units Standard Masterpact designs are available for most manufacturers low voltage switchgear for direct replacement or retrofill applications. Fused for short-circuit protection Choice of Micrologic solid state trip unit devices for overload protection Micrologic trip units provide three levels of protection combined with three levels of functionality: Current (type A), Power (type P) and Harmonics (type H). Functions include: Load protection Power measurement Power monitoring Maintenance monitoring 6

Low and Medium Voltage Circuit Breakers Magnum Medium Voltage Direct Replacement Circuit Breakers Reduced Costs for Equipment Upgrades New circuit breakers installed in existing switchgear Available in 5kV to 15kV versions Utilizes new vacuum and SF6 arc interruption Upgraded MVA ratings are available Installation expense is a fraction of new equipment costs Reduced maintenance and operating costs Less Down Time for Installation Rolls into the existing cell with little-to-no modifications - A bus outage may not even be required Complete factory testing backed by standard equipment warranty Installation overseen by trained technician Enhanced Equipment Reliability Designed to meet ANSI/IEEE C37.59 standards Manufactured with all new components High dielectric strength, moisture resistance, primary insulation Nuclear certification available Available for Most Manufacturer s Equipment General Electric Allis-Chalmers and Siemens/Allis Westinghouse and Cutler-Hammer ITE/ABB McGraw Edison FPE Square D The Magnum operating mechanism is simple to inspect and maintain. 7

Why Choose Square D Services? Square D Services from Schneider Electric, offers a broad range of service solutions to support any manufacturers electrical distribution equipment. Whether the solution is refurbishment, replacement, maintenance or recommendations to optimize your existing system, our nationwide network of qualified experts offers a complete service package. For more information call 1-888-SQUARED or visit us online at www.squared-services.com Emergency Services & Disaster Recovery 1-888-778-2733 24 hours/day 7 days/week Schneider Electric North American Operating Division 9870 Crescent Park Drive West Chester, OH 45069 Tel: 513-777-4445 Fax: 513-755-5028 2009 Schneider Electric. All rights reserved. 1910BR0801 4-09