CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES



Similar documents
OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

OPTICAL FIBER CABLES

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Outside Telephone Cable

B05: Cable protection and sheathing

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

Fibre Optic Indoor/Outdoor Cable

Fibre optic cables MDIC LSZH

INTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

Fibre Optic Cable. Catalogue.

Communication, Signal & Data Cables

GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

EXAMPLE OF RELEVANT STANDARDS

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

International Electrotechnical Commission Standards

FIBER-OPTIC CABLES LWL-KABEL

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

home site map help ECMS Project: Standard / Federal Oversight Advertised

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

P URCHASING D IVISION

OPTICAL FIBRE CABLE APPLICATIONS GUIDELINES

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

The following terms are defined within the context of the fiber optic industry

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

David O Brien, CMP Products (David.OBrien@cmp-products.com)

KGP Logistics Outside Plant Catalog

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Removal of EP SP High Voltage Cable

Polymer Coated Fiber Cable (PCF)

Uniprise Solutions COAX 101. White Paper.

Section kv Power Cables

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

SECTION FIBER OPTIC CABLE AND ACCESSORIES

Coaxial Cables for Medium-Frequency Applications

Fiber Optic Cable

Trunk Cables.

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

ESPECIFICACIÓN DE PRODUCTO

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Network Standard Advice No. 1420C 9/6/2011

P URCHASING D IVISION

CONFLEX ELECTRIC CABLE

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

CAVEL VS80205 MADE IN ITALY 1000 V

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

Signal directionality Lower frequency signals are omnidirectional Higher frequency signals can be focused in a directional beam

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

800 Communications Circuits

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

RELIABILITY OF FIBER OPTIC CABLE SYSTEMS: BURIED FIBER OPTIC CABLE OPTICAL GROUNDWIRE CABLE ALL DIELECTRIC, SELF SUPPORTING CABLE

COAX Cables Radio Frequency Cables

Gulf Cable & Electrical Ind. Co.

SINGLE MODE OPTICAL FIBER FTTH CABLE

Catalogue Câbles d Energie

INTERNATIONAL STANDARD

The Conversion Technology Experts. Fiber Optics Basics

Separation of power and information technology cabling

ScottishPower Distribution Cables & Equipment. Metal Theft

FIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

Screened cable and data cable segregation

Radio-frequency Cables

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance

Lecture 3: Fibre Optics

ALL-DIELECTRIC LOOSE TUBE FIBER OPTIC CABLE

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

The Quality Connection. BETAflam Fire Resistant Safety Cables

MacArtney Underwater Cables - In stock

AERIAL FIBER OPTIC CABLE PLACEMENT

Specifying an IT Cabling System

Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts

2178-S Fiber Optic Splice Case and Accessories

RF & Microwave cable assemblies C291

SINGLE MODE OPTICAL FIBER CABLE

Festoon 715 P PUR cable for flexible application in festoon systems

Industrial Cable Solutions for Variable Frequency Drives

BELFLOW SERIESS FIBER DISTRIBUTION FIBER DISTRIBUTION BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN.

Security & Surveillance Cabling Systems

Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

MEDIUM VOLTAGE CABLES Up to and including 36 KV

Accelerating Light. Copper Cabling Solutions. Category 6A

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Transcription:

AND ADVANTAGES OF OPTICAL FIBER CABLES ADVANTAGES Low attenuation. Long repeater spacings or repeaterless networks. Wide bandwidth. Large transmission capacity with simultaneous voice, data and video transmission capabilities. Immunity from electromagnetic interference. No shielding problems. No crosstalk. Immunity from NEMP (nuclear electromagnetic pulses). Ideal for high security applications. Non-conductive. Transmitter and receiver electrically isolated. Non-inductive. No danger of sparks from short circuits. Perfect for use in hostile environments. Small size, small bending radius and light weight. Space efficient. Ease of installation with resulting cost benefits. Utilisation of existing duct systems. PAGE ONE

OPTICAL FIBER HAS THE CAPACITY TO TRANSMIT ALMOST LIMITLESS AMOUNTS OF INFORMATION

CONTENTS 3 fiber cable product codes 4 Underground (duct) metallic Single Mode optical fiber cable 5 Underground (duct) non-metallic Single Mode optical fiber cable F E R F S B M E D W N STANDARD OPTICAL FIBER CABLE S FIRST LETTER Fiber SECOND LETTER - FIRST SHEATH MATERIAL TYPE Polyethylene Halogen-Free Flame Retardant SUBSEQUENT LETTERS - OTHER KEY Filled Cable Metallic Moisture Barrier Indoor Cable Self-Supporting (Catenary) for Aerial Cable Polyethylene Outer Protective Sheath Tape Armour Wire Armour Non-Metallic Cable TRAILING NUMBER Fibers / Core Diameter / Cladding Diameter EXAMPLES FEFN/2/0/25 Polyethylene Sheathed, Filled, Non-Metallic Cable with 2 Fibers with 0µm core diameter and 25µm cladding diameter. FEFSE/8 Polyethylene Inner Sheathed, Filled, Metallic Moisture Barrier, Polyethylene Outer Sheathed Cable with 8 Fibers. 6 Underground (direct buried) metallic Single Mode optical fiber cable 7 Underground (direct buried) non-metallic Single Mode optical fiber cable 8 Underground (direct buried) armoured Single Mode optical fiber cable 9 General purpose, Lightpack core, LXE-Metallic sheath Single Mode optical fiber cable 0 General purpose, Lightpack core, LXE-Dielectric sheath Single Mode optical fiber cable General purpose, Lightpack core, LXE-Rodent lightning sheath Single Mode optical fiber cable (Based on Saudi Telecom Company MAT-60 specification) PAGE THREE

UNDERGROUND (DUCT) METALLIC SINGLE MODE OPTICAL FIBER CABLE FEFS. Central Strength Member 5. Wrapping Tape 9. Polyethylene Sheath, Black TECH. SPEC. NO. TS - 26000 2. Color Coded Fibers 6. Identification Tape 0. Sheath Marking 3. Color Coded Filled Loose Tubes 7. Glass Yarn Strength Members 4. Filled Interstices 8. Aluminium Moisture Barrier 0 9 8 7 6 5 4 3 2 SM DUCT SA. PTT Single mode, optical fiber cables used in telecommunication network on trunk or inter-exchange routes. The cables are generally hauled into ducts. Single mode color coded fibers, filled color coded loose tubes, MDPE fillers (if required), assembled around a non-metallic central strength member (CSM), filled core, wrapped with dielectric tape, glass yarn strength members, aluminium polymer laminated tape and PE sheath, DUCT METALLIC OPTICAL FIBER CABLE complying with STC MAT - 60 Specification. DUCT METALLIC CABLE Loose Tubes SM Fibers Per Tube 200046 4 2 2 2.5 39 6,000,700 200047 6 3 2 2.5 40 6,000,700 200048 8 4 2 2.5 40 6,000,700 200049 2 6 2 2.5 42 6,000,700 200050 6 4 4 3.0 47 6,000,700 20005 24 6 4 3.0 49 6,000,700 200052 30 5 6 4.5 80 6,000,900 200053 36 6 6 4.5 82 6,000,900 200054 48 6 8 4.5 82 6,000,900 20094 60 5 2 4.5 82 6,000,900 200942 72 6 2 4.5 83 6,000,900 200943 84 7 2 6.0 26 6,000 2,000 200944 96 8 2 6.0 28 6,000 2,000 Single mode fiber optimised at,30 and/or,550nm. Other fiber types/specifications can be offered upon request. Pulling force (maximum): 2,000N Bending radius (minimum): No load - 0 x cable diameter Operating temperature: -30 C, +70 C Storage temperature: -20 C, +70 C Installation temperature: -0 C, +60 C SAUDI CABLE COMPANY TELECABLE DIVISION OPTICAL FIBER CABLE PAGE FOUR

UNDERGROUND (DUCT) NON-METALLIC SINGLE MODE OPTICAL FIBER CABLE FEFN. Central Strength Member 5. Wrapping Tape 9. Sheath Marking TECH. SPEC. NO. TS - 26000 2. Color Coded Fibers 6. Identification Tape 3. Color Coded Filled Loose Tubes 7. Glass Yarn Strength Members 4. Filled Interstices 8. Polyethylene Sheath, Black 9 8 7 6 5 4 3 2 SM DUCT SA. PTT Single mode, optical fiber cables used in telecommunication network on trunk or inter-exchange routes. The cables are generally hauled into ducts. Single mode color coded fibers, filled color coded loose tubes, MDPE fillers (if required), assembled around a non-metallic central strength member (CSM), filled core, wrapped with dielectric tape, glass yarn strength members and PE sheath, DUCT NON-METALLIC OPTICAL FIBER CABLE complying with STC MAT - 60 Specification. DUCT METAL FREE CABLE Loose Tubes SM Fibers Per Tube 200055 4 2 2 2.0 8 6,000,700 200056 6 3 2 2.0 8 6,000,700 200057 8 4 2 2.0 9 6,000,700 200058 2 6 2 2.0 20 6,000,700 200059 6 4 4 2.5 25 6,000,700 200060 24 6 4 2.5 27 6,000,700 20006 30 5 6 4.0 56 6,000,800 200062 36 6 6 4.0 57 6,000,800 200063 48 6 8 4.0 58 6,000,800 200945 60 5 2 4.0 58 6,000,800 200946 72 6 2 4.0 59 6,000,800 200947 84 7 2 5.5 9 6,000,900 200948 96 8 2 5.5 93 6,000,900 Single mode fiber optimised at,30 and/or,550nm. Other fiber types/specifications can be offered upon request. Pulling force (maximum): 2,000N Bending radius (minimum): No load - 0 x cable diameter Operating temperature: Storage temperature: Installation temperature: -30 C, +70 C -20 C, +70 C -0 C, +60 C PAGE FIVE

UNDERGROUND (DIRECT BURIED) METALLIC SINGLE MODE OPTICAL FIBER CABLE FEFSE. Central Strength Member 5. Wrapping Tape 9. Inner Polyethylene Sheath TECH. SPEC. NO. TS - 26000 2. Color Coded Fibers 6. Identification Tape 0. Flooding Compound 3. Color Coded Filled Loose Tubes 7. Glass Yarn Strength Members. Outer Polyethlyene Sheath, Black 4. Filled Interstices 8. Aluminium Moisture Barrier 2. Sheath Marking 2 0 9 8 7 6 5 4 3 2 SM SA. PTT Single mode, optical fiber cables generally used in telecommunication network on trunk or inter-exchange routes. The cables are used for outdoor direct burial application. Single mode color coded fibers, filled color coded loose tubes, MDPE fillers (if required), assembled around a non-metallic central strength member (CSM), filled core, wrapped with dielectric tape, glass yarn strength members, aluminium polymer laminated tape, PE inner and outer sheath, DIRECT BURIED METALLIC OPTICAL FIBER CABLE complying with STC MAT - 60 Specification. DIRECT BURIED METALLIC CABLE Loose Tubes SM Fibers Per Tube 200064 4 2 2 5.0 8 6,000,900 200065 6 3 2 5.0 8 6,000,900 200066 8 4 2 5.0 82 6,000,900 200067 2 6 2 5.0 83 6,000,900 200068 6 4 4 5.0 83 6,000,900 200069 24 6 4 5.0 84 6,000,900 200070 30 5 6 6.0 20 6,000 2,000 20007 36 6 6 6.0 2 6,000 2,000 200072 48 6 8 6.0 22 6,000 2,000 200949 60 5 2 6.5 22 6,000 2,000 200950 72 6 2 6.5 223 6,000 2,000 20095 84 7 2 8.0 263 6,000 2,00 200952 96 8 2 8.0 264 6,000 2,00 Single mode fiber optimised at,30 and/or,550nm. Other fiber types/specifications can be offered upon request. Pulling force (maximum):,000n Bending radius (minimum): No load - 0 x cable diameter Operating temperature: Storage temperature: Installation temperature: -30 C, +70 C -20 C, +70 C -0 C, +60 C SAUDI CABLE COMPANY TELECABLE DIVISION OPTICAL FIBER CABLE PAGE SIX

UNDERGROUND (DIRECT BURIED) NON-METALLIC SINGLE MODE OPTICAL FIBER CABLE FEFNE. Central Strength Member 5. Wrapping Tape 9. Filling Compound TECH. SPEC. NO. TS - 26000 2. Color Coded Fibers 6. Identification Tape 0. Outer Polyethylene Sheath, Black 3. Color Coded Filled Loose Tubes 7. Glass Yarn Strength Members. Sheath Marking 4. Filled Interstices 8. Inner Polyethlyene Sheath 0 9 8 7 6 5 4 3 2 SM SA. PTT Single mode, optical fiber cables generally used in telecommunication network on trunk or inter-exchange routes. The cables are for outdoor direct burial application. Single mode color coded fibers, filled color coded loose tubes, MDPE fillers (if required), assembled around a non-metallic central strength member (CSM), filled core, wrapped with dielectric tape, glass yarn strength members, PE inner and outer sheath, DIRECT BURIED NON-METALLIC OPTICAL FIBER CABLE complying with STC MAT - 60 Specification. DIRECT BURIED METAL FREE CABLE Loose Tubes SM Fibers Per Tube 200073 4 2 2 4.0 48 6,000,800 200074 6 3 2 4.0 49 6,000,800 200075 8 4 2 4.0 50 6,000,800 200076 2 6 2 4.0 5 6,000,800 200077 6 4 4 4.0 5 6,000,800 200078 24 6 4 4.0 5 6,000,800 200079 30 5 6 6.0 90 6,000 2,000 200080 36 6 6 6.0 92 6,000 2,000 20008 48 6 8 6.0 92 6,000 2,000 200953 60 5 2 6.0 96 6,000 2,000 200954 72 6 2 6.0 97 6,000 2,000 200955 84 7 2 7.5 234 6,000 2,00 200956 96 8 2 7.5 236 6,000 2,00 Single mode fiber optimised at,30 and/or,550nm. Other fiber types/specifications can be offered upon request. Pulling force (maximum):,000n Bending radius (minimum): No load - 0 x cable diameter Operating temperature: Storage temperature: Installation temperature: -30 C, +70 C -20 C, +70 C -0 C, +60 C PAGE SEVEN

UNDERGROUND (DIRECT BURIED) ARMOURED SINGLE MODE OPTICAL FIBER CABLE FEFSDE. Central Strength Member 5. Wrapping Tape 9. Inner Polyethylene Sheath TECH. SPEC. NO. TS - 26000 2. Color Coded Fibers 6. Identification Tape 0. Corrugated Steel Tape 3. Color Coded Filled Loose Tubes 7. Glass Yarn Strength Members. Outer Polyethlyene Sheath, Black 4. Filled Interstices 8. Aluminium Moisture Barrier 2. Sheath Marking 2 0 9 8 7 6 5 4 3 2 SM SA. PTT Single mode, optical fiber cables generally used in telecommunication network on trunk or inter-exchange routes. The cables are used for outdoor direct burial application. Single mode color coded fibers, filled color coded loose tubes, MDPE fillers (if required), assembled around a non-metallic central strength member (CSM), filled core, wrapped with dielectric tape, glass yarn strength members, aluminium polymer laminated tape, PE inner sheath, corrugated steel tape and PE outer sheath, DIRECT BURIED ARMOURED OPTICAL FIBER CABLE complying with STC MAT - 60 Specification. DIRECT BURIED ARMOURED CABLE Loose Tubes SM Fibers Per Tube 200082 4 2 2 7.0 248 6,000 2,00 200083 6 3 2 7.0 249 6,000 2,00 200084 8 4 2 7.0 249 6,000 2,00 200085 2 6 2 7.0 250 6,000 2,00 200086 6 4 4 7.0 250 6,000 2,00 200957 20 5 4 7.0 25 6,000 2,00 200087 24 6 4 7.0 25 6,000 2,00 200088 30 5 6 9.0 304 6,000 2,300 200089 36 6 6 9.0 305 6,000 2,300 200090 48 6 8 9.0 305 6,000 2,300 200958 60 5 2 9.0 305 6,000 2,300 200959 72 6 2 9.0 306 6,000 2,300 200960 84 7 2 20.5 350 4,000 2,00 20096 96 8 2 20.5 352 4,000 2,00 Single mode fiber optimised at,30 and/or,550nm. Other fiber types/specifications can be offered upon request. Pulling force (maximum):,000n Bending radius (minimum): No load - 0 x cable diameter Operating temperature: Storage temperature: Installation temperature: -30 C, +70 C -20 C, +70 C -0 C, +60 C SAUDI CABLE COMPANY TELECABLE DIVISION OPTICAL FIBER CABLE PAGE EIGHT

GENERAL PURPOSE, LIGHTPACK CORE, LXE-METALLIC SHEATH SINGLE MODE OPTICAL FIBER CABLE LXE - ME. Fibers in Bundle(s) with Color 3. Water Blocking Tape 6. Sheath Rip Cords TECH.SPEC.NO. TS - 38000 Coded Marker Thread 4. Corrugated ECCS Steel Tape 7. Polyethylene Sheath, Black 2. Filled PBT Core Tube 5. Steel Wire Strength Members 8. Sheath Marking 8 7 6 5 4 3 2 LXE-ME Single mode, Lightpack Metallic Sheath (LXE-ME) fiber cables generally used in telecommunication network on trunk or Inter-exchange routes for underground Duct, Direct Buried, or Aerial applications. The cable conforms to the requirements of International Standards such as IEC 794-, Bellcore GR-20-CORE and REA Bulletin 753F-60 (PE-90) for, and Characteristics. Single mode color coded fibers, filled central core tube, wrapped with a water blocking tape, corrugated ECCS steel tape armour, steel wire strength members and PE sheath, Lightpack Metallic sheath (LXE-ME) OPTICAL FIBER CABLE. LIGHTPACK METALLIC SHEATH (LXE-ME) CABLE Nominal Core Tube Dia. 25000 4 6.0 2.90 78 6,000,700 250002 6 6.0 2.90 78 6,000,700 250003 8 6.0 2.90 78 6,000,700 250004 0 6.0 2.90 78 6,000,700 250005 2 6.0 2.90 78 6,000,700 250006 6 6.0 2.90 78 6,000,700 250007 20 6.0 2.90 78 6,000,700 250008 24 6.0 2.90 79 6,000,700 250009 30 6.0 2.90 79 6,000,700 25000 36 6.0 2.90 79 6,000,700 2500 48 6.0 2.90 80 6,000,700 25002 52 8.0 5.40 238 6,000 2,000 25003 60 8.0 5.40 238 6,000 2,000 25004 64 8.0 5.40 238 6,000 2,000 25005 72 8.0 5.40 238 6,000 2,000 25006 76 8.0 5.40 239 6,000 2,000 25007 84 8.0 5.40 239 6,000 2,000 25008 96 8.0 5.40 240 6,000 2,000 Single mode fiber optimised at,30 and/or,550nm. Other fiber types/specifications can be offered upon request. Pulling force (maximum) : 2,700N Bending radius (minimum) : No load - 0 x cable diameter Operating temperature : -40 C, +70 C Storage temperature : -40 C, +75 C Installation temperature : -30 C, +60 C PAGE NINE LXE-ME is a trademark of Lucent Technologies and is manufactured by -T under their licence.

GENERAL PURPOSE, LIGHTPACK CORE, LXE-DIELECTRIC SHEATH SINGLE MODE OPTICAL FIBER CABLE LXE - DE. Fibers in Bundle(s) with Colour 3. Water Blocking Tape 6. Sheath Rip Cords TECH.SPEC.NO. TS - 39000 Coded Marker Thread 4. Glass Roving Strength Members 7. Polyethylene Sheath, Black 2. Filled PBT Core Tube 5. Glass Rod Strength Members 8. Sheath Marking 8 7 6 5 4 3 2 LXE-DE Single mode, Lightpack Dielectric Sheath (LXE-DE) fiber cables generally used in telecommunication network on trunk or Inter-exchange routes for underground Duct, Direct Buried, or Aerial applications. The cable conforms to the requirements of International Standards such as IEC 794-, Bellcore GR-20-CORE and REA Bulletin 753F-60 (PE-90) for, and Characteristics. Single mode color coded fibers, filled central core tube, wrapped with a water blocking tape, Non-Metallic glass strength members and PE sheath, Lightpack Dielectric sheath (LXE-DE) OPTICAL FIBER CABLE. LIGHTPACK DIELECTRIC SHEATH (LXE -DE) CABLE Nominal Core Tube Dia. 25009 4 6.0 2.90 5 6,000,700 250020 6 6.0 2.90 5 6,000,700 25002 8 6.0 2.90 5 6,000,700 250022 0 6.0 2.90 5 6,000,700 250023 2 6.0 2.90 5 6,000,700 250024 6 6.0 2.90 5 6,000,700 250025 20 6.0 2.90 5 6,000,700 250026 24 6.0 2.90 5 6,000,700 250027 30 6.0 2.90 52 6,000,700 250028 36 6.0 2.90 52 6,000,700 250029 48 6.0 2.90 52 6,000,700 250030 52 8.0 5.40 207 6,000 2,000 25003 60 8.0 5.40 207 6,000 2,000 250032 64 8.0 5.40 208 6,000 2,000 250033 72 8.0 5.40 208 6,000 2,000 250034 76 8.0 5.40 208 6,000 2,000 250035 84 8.0 5.40 209 6,000 2,000 250036 96 8.0 5.40 209 6,000 2,000 Single mode fiber optimised at,30 and/or,550nm. Other fiber types/specifications can be offered upon request. Pulling force (maximum) : 2,700N Bending radius (minimum) : No load - 0 x cable diameter Operating temperature : -40 C, +70 C Storage temperature : -40 C, +75 C Installation temperature : -30 C, +60 C SAUDI CABLE COMPANY TELECABLE DIVISION OPTICAL FIBER CABLE PAGE TEN LXE-DE is a trademark of Lucent Technologies and is manufactured by -T under their licence.

GENERAL PURPOSE, LIGHTPACK CORE, LXE-RODENT LIGHTNING SHEATH SINGLE MODE OPTICAL FIBER CABLE LXE - RL. Fibers in Bundle(s) with Colour 3. Water Blocking Tape 6. Sheath Rip Cords TECH.SPEC.NO. TS - 40000 Coded Marker Thread 4. Corrugated Stainless Steel Tape 7. Polyethylene Sheath, Black 2. Filled PBT Core Tube 5. Steel Wire Strength Members 8. Sheath Marking 8 7 6 5 4 3 2 LXE-RL Single mode, Lightpack Rodent-lightning sheath (LXE-RL) fiber cables generally used in telecommunication network on trunk or inter-exchange routes for underground Duct, Direct Buried, or Aerial applications. The cable conforms to the requirements of International Standards such as IEC 794-, Bellcore GR-20-CORE and REA Bulletin 753F-60 (PE-90) for, and Characteristics. Single mode color coded fibers, filled central core tube, wrapped with a water blocking tape, corrugated stainless steel tape armour, steel wire strength members and PE sheath, Lightpack Rodent-Lightning sheath (LXE-RL) OPTICAL FIBER CABLE. LIGHTPACK RODENT-LIGHTNING SHEATH (LXE-RL) CABLE Nominal Core Tube Dia. 250037 4 6.0 2.90 75 6,000,700 250038 6 6.0 2.90 75 6,000,700 250039 8 6.0 2.90 75 6,000,700 250040 0 6.0 2.90 75 6,000,700 25004 2 6.0 2.90 76 6,000,700 250042 6 6.0 2.90 76 6,000,700 250043 20 6.0 2.90 76 6,000,700 250044 24 6.0 2.90 76 6,000,700 250045 30 6.0 2.90 77 6,000,700 250046 36 6.0 2.90 77 6,000,700 250047 48 6.0 2.90 77 6,000,700 250048 52 8.0 5.40 229 6,000 2,000 250049 60 8.0 5.40 229 6,000 2,000 250050 64 8.0 5.40 230 6,000 2,000 25005 72 8.0 5.40 230 6,000 2,000 250052 76 8.0 5.40 230 6,000 2,000 250053 84 8.0 5.40 23 6,000 2,000 250054 96 8.0 5.40 23 6,000 2,000 Single mode fiber optimised at,30 and/or,550nm. Other fiber types/specifications can be offered upon request. Pulling force (maximum) : 2,700N Bending radius (minimum) : No load - 0 x cable diameter Operating temperature : -40 C, +70 C Storage temperature : -40 C, +75 C Installation temperature : -30 C, +60 C PAGE ELEVEN LXE-RL is a trademark of Lucent Technologies and is manufactured by -T under their licence.