CHAPTER 6 CONSTRUCTION TYPES



Similar documents
FIRE AND SMOKE PROTECTION FEATURES

Excerpts from the Canadian National Building Code (NBC)

FIRE AND SMOKE PROTECTION FEATURES

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

Certification: Building Plans Examiner. Exam ID: B3

POST AND FRAME STRUCTURES (Pole Barns)

FIRE-RESISTANCE-RATED CONSTRUCTION

FIRE-RESISTANCE-RATED CONSTRUCTION

Chapter 6 ROOF-CEILING SYSTEMS

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Building Code Clarifications - 7. Fire Resistance

Fire-Retardant-Treated (FRT) Plywood

Residential Deck Safety, Construction, and Repair

ISO Types 1-6: Construction Code Descriptions

COMMONLY USED RESIDENTIAL BUILDING CODES

Post and Beam Construction

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

What is Seismic Retrofitting?

Building Construction. Lightweight construction. Conventional Construction

SECTION 3 ONM & J STRUCTURAL ANALYSIS

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

SUPERIOR FIRE RESISTANCE

Uncovered Decks & Porches

Engineers, Civil Structural Survey

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS

Mark Cramer Inspection Services, Inc.

Residential Decks. Planning and Development Services Department

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

H-Stud Area Separation Wall System

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

Wood use in Type I and II (noncombustible) construction

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

EAST LYME HIGH SCHOOL

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

- 5 - Table1. Maximum Compartment Volumes

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

8/18/14. Introduction to. Framing. Terminology and Concepts

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Building Condition Assessment: North Howard Street Baltimore, Maryland

Timber Decks. Technical Note. March 2007

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

5.0 wall ApplicAtions

Handling, Erection and Bracing of Wood Trusses

STANDARD OPEN PATIO COVER

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

CHIMNEYS AND FIREPLACES

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Clark County Fire Prevention

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

Discipline: Structural Issued

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

INSTALLATION. General. Important Note. Design. Transport

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

One-third of all fatalities in the U.S. construction

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

PANELIZED HOME INSTALLATION GUIDELINE

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

Georgia Association of Home Inspectors

How to secure your property after a disaster

Bracing Webs in Trusses that have Dissimilar Configurations

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

PDmB, Inc. Definitions

Building Condition Assessment: West Lexington Street Baltimore, Maryland

AUTHORIZATION TO MARK

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

TYPICAL PATIO COVERS 111

Additions and Alterations

Analysis II Façade Redesign: Architectural Precast Panels

Elevating Your House. Introduction CHAPTER 5

Expected Performance Rating System

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

FORM DESIGN. easy to work with, and generally available.

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

CH. 2 LOADS ON BUILDINGS

2009 IECC Update. Scope. Content. International Energy Conservation Code

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Typical Deck Details

Patio Covers / Carports

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Transcription:

CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use of more than one construction type in a building. 601.2 Classification by type of construction 601.2.1 Every building shall be classified by the building official into one of the types of construction as set forth in this section. Type I Type V Type II 1-Hour Protected Type III Type IV Type VI 1 -Hour Protected 1 -Hour Protected 601.2.2 Materials for any one of the six types of construction may be used as specified in Table 600, or as permitted in this chapter. 601.3 Fire resistance requirements 601.3.1 All fire resistance requirements are expressed in terms of the number of hours of satisfactory performance in accordance with ASTM E 119. 601.3.2 Construction required to have a fire resistance rating shall be supported by construction of equal or greater fire resistance. Exception: In Types IV, V and VI construction, structural elements supporting exit access corridor walls and tenant separation walls of not more than one (1) hour fire resistance need not be rated provided a fire resistance rating is not required by other provisions of this code. 601.4 Materials and construction approved for fire resistance 601.4.1 The degree of fire resistance and the materials, assemblies and constructions providing such resistance shall be defined in Chapter 7 of this code, except that other materials, assemblies and constructions shall be approved, provided test data of a recognized engineering or testing laboratory are submitted, establishing that they develop the required fire resistance rating under tests made in accordance with ASTM E 119 or based on calculations and accepted engineering practice as set forth in 709. 601.4.2 Where structural requirements necessitate assemblies providing greater fire resistance than specified in this chapter, such structural requirements shall govern. For definitions, see Chapter 2. SECTION 602 DEFINITIONS SECTION 603 TYPE I CONSTRUCTION Type I is construction in which the structural members beams, girders, trusses, arches, floors, and roofs are of noncombustible materials and are protected so as to have fire resistance not less than that specified for the structural elements as specified in Table 600. For interior nonbearing partition requirements, see 704.2. For provisions governing combustibles in concealed spaces, see 707. SECTION 604 TYPE II CONSTRUCTION Type II is construction in which the structural members beams, girders, trusses, arches, floors and roofs are of noncombustible materials and are protected so as to have fire resistance not less than that specified for the structural elements as specified in Table 600. For interior nonbearing partition requirements, see 704.2. For provisions governing combustibles in concealed spaces, see 707. SECTION 605 TYPE III CONSTRUCTION 605.1 General. Type III is construction in which fire resistance is attained by the sizes of heavy timber members (sawn or glued laminated) being not less than indicated in this section, or by providing fire resistance not less than one (1) hour where materials other than wood of heavy timber sizes are used; by the avoidance of concealed spaces under floors and roofs; by the use of approved fastenings, construction details and adhesives for structural members; and by providing the required degree of fire resistance in exterior and interior walls. 605.2 Columns 605.2.1 Wood columns may be sawn or glued laminated and shall be not less than eight (8) inches nominal in any dimension when supporting floor loads, and not less than six (6) inches nominal wide and eight (8) inches nominal deep when supporting roof and ceiling loads only. FLORIDA BUILDING CODE BUILDING 6.1

605.2.2-605.8.2 605.2.2 Columns shall be continuous or superimposed throughout all stories by means of reinforced concrete or metal caps with brackets, or shall be connected by properly designed steel or iron caps, with pintles and base plates, or by timber splice plates affixed to the columns by means of metal connectors housed within the contact faces, or by other approved methods. 605.3 Floor framing 605.3.1 Beams and girders of wood may be sawn or glued laminated and shall be not less than 6 inches nominal wide and not less than 10 inches nominal deep. 605.3.2 Framed or glued laminated arches which spring from the floor line and support floor loads shall be not less than 8 inches nominal in any dimension. 605.3.3 Framed timber trusses supporting floor loads shall have members of not less than 8 inches nominal in any dimension. 605.4 Roof framing 605.4.1 Framed or glued laminated arches for roof construction which spring from the floor line and do not support floor loads shall have members not less than 6 inches nominal wide and 8 inches nominal deep for the lower half of the height and not less than 6 inches nominal in any dimension for the upper half of the height. 605.4.2 Framed or glued laminated arches for roof construction which spring from the top of walls or wall abutments, framed timber trusses and other roof framing which do not support floor loads, shall have members not less than 4 inches nominal wide and not less than 6 inches nominal deep. Spaced members may be composed of two or more pieces not less than 3 inches nominal thick when blocked solidly throughout their intervening spaces or when such spaces are tightly closed by a continuous wood cover plate of not less than 2 inches nominal thick, secured to the underside of the members. Splice plates shall be no less than 3 inches nominal thick. When protected by approved automatic sprinklers under the roof deck, such framing members shall be not less than 3 inches nominal wide. 605.5 Construction details 605.5.1 Wall plate boxes of self-releasing type, or approved hangers, shall be provided where beams and girders enter masonry. An air space of 1 / 2 inch (12.7 mm) shall be provided at the top, ends and sides of the member unless approved naturally durable or preservative-treated wood is used. 605.5.2 Girders and beams shall be closely fitted around columns and adjoining ends shall be cross-tied to each other, or inter-tied by caps or ties, to transfer horizontal loads across the joint. Wood bolsters may be placed on tops of columns which support roof loads only. 605.5.3 Where intermediate beams are used to support floors, they shall rest on top of the girders, or shall be supported by ledgers or blocks securely fastened to the sides of the girders, or they may be supported by approved metal hangers into which the ends of the beams shall be fitted closely. 605.5.4 Columns, beams, girders, arches and trusses of material other than wood shall have afireresistance rating of not less than 1 hour. 605.5.5 Wood beams and girders supported by walls required to have a fire resistance rating of 2 hours or more shall have not less than 4 inches (102 mm) of solid masonry between their ends and the outside face of the wall, and between adjacent beams. 605.5.6 Adequate roof anchorage shall be provided. 605.6 Floor decks. Floors shall be without concealed spaces. They shall be of sawn or glued laminated plank, splined, or tongue-and-grooved, not less than 3 inches nominal thick, or of planks not less than 4 inches nominal wide set on edge and well-spiked together. The planks shall be laid so that no continuous line of joints will occur except at points of support and they shall not be spiked to supporting girders. Planks shall be covered with 1 inch nominal tongue-and-groove flooring laid crosswise or diagonally or with 15 / 32 inch (11.9 mm) wood structural panels. Planks and flooring shall not extend closer than 1 / 2 inch (12.7 mm) to walls to provide an expansion joint, and the joint shall be covered at top or bottom. 605.7 Roof decks. Roofs shall be without concealed spaces and roof decks shall be sawn or glued laminated, splined or tongue and grooved plank, not less than 2 inches nominal thick, or of planks not less than 3 inches nominal wide, set on edge and spiked together as required for floors, or of 1 1 / 8 inch (29 mm) tongue and grooved wood structural panels bonded with exterior glue. Other types of decking may be used when approved by the building official. 605.8 Walls 605.8.1 Bearing portions of exterior and interior walls shall be of approved noncombustible materials and shall provide fire resistance ratings in accordance with Table 600. 605.8.2 Nonbearing portions of exterior walls shall be of approved noncombustible materials and shall provide fire resistance ratings in accordance with Table 600. Exception: Where a horizontal separation of at least 20 ft (6096 mm) is provided, wood columns, arches, beams and roof decks conforming to heavy timber sizes may be used externally. 6.2 FLORIDA BUILDING CODE BUILDING

606-610.3 SECTION 606 TYPE IV CONSTRUCTION Type IV is construction in which the structural members beams, girders, trusses, arches, floors and roofs are of noncombustible materials. Type IV construction may be protected or unprotected. Fire resistance requirements for structural elements of Type IV construction shall be as specified in Table 600. For provisions governing combustibles in concealed spaces, see 707. SECTION 607 TYPE V CONSTRUCTION Type V is construction in which the exterior bearing and nonbearing walls are of noncombustible material and have fire resistance not less than that specified in Table 600; bearing portions of interior walls are of material permitted in Table 600, and have fire resistance not less than that specified in Table 600; and beams, girders, trusses, arches, floors, floors.and interior framing are wholly or partly of wood or other approved materials and have fire resistance not less than that specified in Table 600. Type V construction may be either protected or unprotected. Fire resistance requirements for structural elements of Type V construction shall be as specified in Table 600. SECTION 608 TYPE VI CONSTRUCTION Type VI is construction in which the exterior bearing and nonbearing walls and partitions, beams, girders, trusses, arches, floors, and roofs and their supports are wholly or partly of wood or other approved materials. Type VI construction may be either protected or unprotected. Fire resistance requirements for structural elements of Type VI construction shall be as specified in Table 600. SECTION 609 PARTITIONS 609.1 Bearing walls shall comply with the provisions of Chapter 6, but shall provide not less than the degree of fire resistance specified in Table 600. 609.2 Nonbearing partitions shall conform to 609.2.1 through 609.2.4 and have the fire resistance specified in Table 705.1.2 except as specified elsewhere in this code. 609.2.1 Type I and Type II construction. Partitions shall be constructed of noncombustible materials. Exceptions: 1. Framing members may be of fire retardant treated wood. 2. Pocket doors and their frames may be of wood. 609.2.3 Type IV construction. Partitions shall be constructed of noncombustible materials except that framing members of fire retardant treated wood may be used and pocket doors and their frames may be of wood. Partitions in one-story buildings only may be of any material permitted by this code. Partitions in fully sprinklered buildings, regardless of height, may be of any material permitted by this code. 609.2.4 Type V and Type VI construction. Partitions may be of any material permitted by this code. SECTION 610 MIXED TYPES OF CONSTRUCTION 610.1 Area limitations. Where two or more types of construction not separated by fire walls occur in the same building, the area of the entire building shall not exceed the least area permitted based on occupancy for the types of construction used in the building. 610.2 Height limitations. Where two or more types of construction occur in the same building, the height of the entire building shall not exceed the least height permitted based on the occupancy for the types of construction used in the building. 610.3 Open parking structures. Open parking structures which comply with 411.3 may be constructed beneath other occupancies in buildings of mixed types of construction in accordance with the following: 1. The height and area of the open parking structure shall not exceed that permitted by Table 411.3.1 for the type of construction of the open parking structure. 2. The total height of the structure shall not exceed that allowed for its primary occupancy in accordance with 303 and Table 500. 3. The fire resistance of structural members within the open parking structure that support any part of the building above the open parking structure shall have the same or greater fire resistance as the supported type of construction. This provision applies to all columns; beams, girders, and trusses directly connected to the columns; and all other structural members which directly brace the columns. 4. The entire structure shall be of noncombustible construction. 5. Occupancy separations shall be maintained in accordance with 704.1. 6. All exits for the upper occupancy shall be protected to the exterior of the building in accordance with Chapter 10. 609.2.2 Type HI construction. Partitions may be of any material permitted by this code. FLORIDA BUILDING CODE BUILDING 6.3

TABLE 600 TABLE 600 FIRE RESISTANCE RATINGS REQUIRED FIRE RESISTANCE IN HOURS TYPE IV TYPE V TYPE VI STRUCTURAL TYPE I TYPE II TYPE III 1-Hour 1-Hour 1-Hour ELEMENT Protected Protected Protected PARTY AND FIRE WALLS (a) 4 4 4 4 4 4 4 4 4 INTERIOR BEARING WALLS (I) Supporting columns, other bearing walls or more than one floor 4 3 2 1 NC 1(h) 0(h) 1 0 Supporting one floor only 3 2 1 1 NC 1 0 1 0 Supporting roofs only 3 2 1 1 NC 1 0 1 0 INTERIOR NONBEARING PARTITIONS See 609.2, 704.1, 704.2 and 705.2 COLUMNS (q) (1) See 605 Supporting other columns or more than one floor 4 3 H(d) 1 NC 1 0 1 0 Supporting one floor only 3 2 H(d) 1 NC 1 0 1 0 Supporting roofs only 3 2 H(d) 1 NC 1 0 1 0 BEAMS, GIRDERS, TRUSSES & ARCHES (1) See 605 Supporting columns or more than one floor 4 3 H(d) 1 NC 1 0 1 0 Supporting one floor only 3 2 H(d) 1 NC 1 0 1 0 Supporting roofs only l 1 / 2 (e,p) 1 (e,f,p) H(d) Ke,p) NC(e) 1 0 1 0 FLOORS & FLOOR/CEILING (1) See 605 (n) (n,o) (n) (m,n,o) (o) ASSEMBLIES 3 2 H(o) 1 NC 1 0 1 0 ROOFS & ROOF/CEILING See 605 ASSEMBLIES (g) 1 1 / 2 (e.p) 1 (e,f,p) H(d) l(e,p) NC(e) 1 0 1 0 EXTERIOR BEARING WALLS and gable ends of roof (g. i, j) (% indicates percent of protected and unprotected wall openings permitted. See 705.1.1 for protection requirements.) Horizontal separation (distance from common property line or assumed property line). 0 ft to 3 ft (c) 4(0%) 3(0%) 3(0%)(b) 2(0%) 1(0%) 3(0%)(b) 3(0%Xb) 1(0%) 1(0%) over 3 ft to 10 ft(c) 4(10%) 3(10%) 2(10%)(b) 1(10%) 1(10%) 2(10%)(b) 2(10%)(b) 1(20%) 0(20%) over 10 ft to 20 ft (c) 4(20%) 3(20%) 2(20%)(b) 1(20%) NC(20%) 2(20%)(b) 2(20%)(b) 1(40%) 0(40%) over 20 ft to 30 ft 4(40%) 3(40%) 1(40%) 1(40%) NC(40%) 1(40%) 1(40%) 1(60%) 0(60%) over 30 ft 4(NL) 3(NL) 1(NL) 1(NL) NC(NL) 1(NL) 1(NL) 1(NL) 0(NL) EXTERIOR NONBEARING WALLS and gable ends of roof (g, i, j) (% indicates percent of protected and unprotected wall openings permitted. See 705.1.1 for protection requirements.) Horizontal separation (distance from common property line or assumed property line). 0 ft to 3 ft (c) 3(0%) 3(0%) 3(0%)(b) 2(0%) 1(0%) 3(0%Xb) 3(0%)(b) 1(0%) 1(0%) over 3 ft to 10 ft (c) 2(10%) 2(10%) 2(10%)(b) 1(10%) 1(10%) 2(10%Xb) 2(10%)(b) 1(20%) 0(20%) over 10 ft to 20 ft (c) 2(20%) 2(20%) 2(20%)(b) 1(20%) NC(20%) 2(20%)(b) 2(20%)(b) 1(40%) 0(40%) over 20 ft to 30 ft 1(40%) 1(40%) 1(40%) NC(40%) NC(40%) 1(40%) 1(40%) 0(60%) 0(60%) over 30 ft (k) NC (NL) NC(NL) NC(NL) NC(NL) NC(NL) NC(NL) NC(NL) 0(NL) 0(NL) For SI: 1 ft = 0.305 m. NC = Noncombustible NL = No Limits H = Heavy Timber Sizes 6.4 FLORIDA BUILDING CODE BUILDING

TABLE 600 NOTES Notes: a. See 704.S for extension of party walls and fire walls. b. See 704.5 for parapets. c. See 70S for protection of wall openings. d. Where horizontal separation of 20 ft or more is provided, wood columns, arches, beams, and roof deck conforming to heavy timber sizes may be used externally. e. In buildings not over two stories approved fire retardant treated wood may be used. f. In one-story buildings, structural members of heavy timber sizes may be used as an alternate to unprotected structural roof members. Stadiums, field houses and arenas with heavy timber wood dome roofs are permitted. An approved automatic sprinkler system shall be installed in those areas where 20 ft clearance to the floor or balcony below is not provided. g. See 1511 for penthouses and roof structures. h. The use of combustible construction for interior bearing partitions shall be limited to the support of not more than two floors and a roof. i. Exterior walls shall be fire tested in accordance with 601.3. The fire resistance requirements for exterior walls with 5 ft or less horizontal separation shall be based upon both interior and exterior fire exposure. The fire resistance requirements for exterior walls with more than 5 ft horizontal separation shall be based upon interior fire exposure only. j. Where Appendix F is specifically included in the adopting ordinance, see F102.2.6 for fire resistance requirements for exterior walls of Type IV buildings in Fire District. k. Walls or panels shall be of noncombustible material or fire retardant treated wood, except for Type VI construction. 1. For Group A - Large Assembly, Group A Small Assembly, Group B, Group E, Group F, Group R occupancies and Automobile Parking Structures, occupancies of Type I construction, partitions, columns, trusses, girders, beams, and floors may be reduced by 1 hour if the building is equipped with an automatic sprinkler system throughout, but no component or assembly may be less than 1 hour. m Group A - Large Assembly (no stage requiring proscenium opening protection) and Group A - Small Assembly occupancies of Type V construction shall have 1 -hour fire resistant floors over any crawl space or basement. n. For Group B and Group M occupancies of Type IV or Type V construction, when five or more stories in height a 2-hour fire resistant floor shall be required over the basement. o. For unsprinklered Group E occupancies of Type III, Type IV, Type V or Type VI, floors located immediately above useable space in basements shall have a fire resistant rating of not less than I hour. p. In buildings of Group A, B, E, and R occupancies, the required fire resistance of the roof or roof/ceiling assembly including the beams, girders, trusses. or arches that support the roof only may be omitted where every part of the roof structural members have a clear height of 20 ft (6096 mm) or more above any floor, mezzanine or balcony. q. See 701.4. FLORIDA BUILDING CODE BUILDING 6.5