AUTHORIZATION TO MARK
|
|
|
- Suzan Anderson
- 9 years ago
- Views:
Transcription
1 AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report(s). This authorization also applies to the Multiple Listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The Certification Mark(s) may be applied only at the location of the Party Authorized to Apply Mark. Applicant: Timberline Panel Company, LLC 12 Spring Street Schuylerville NY Country: Contact: Thomas R. Harrison Phone: Fax: Party Authorized to Apply Mark: Evaluation Center: See following page(s) Intertek (Coquitlam) Control/Client Number: This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Testing Standard{s}: :CAN / ULC S101 (2007):ASTM E119 (2012) Product: Timberline Panel Company - Structural Insulated Panels (SIPs) ATM for Report ITSCERT ATM Issue Date: 04/28/2015 Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 1 of 12
2 Listing Section(s): BUILDING PANELS CSI Code: Description: RATINGS Structural Panels Structural Insulated Panels are factory-assembled, engineered-wood-faced, structural insulated panels (SIPs) with an expanded polystyrene (EPS) foam core. The panels are intended for use as loadbearing or non-load bearing wall and roof panels. The panels are custom made to the specifications for each use and are assembled under factory-controlled conditions. ASTM E119 / CAN/ULC S101 Fire-Resistance Rating Design Number 6-1/2 in. SIP Wall Assembly 1-hour rating TPC/CWP /2, 6-1/2 or 8-1/4 in. SIP Wall 1-hour rating TPC/CWP Assembly SIP Wood Roof/Ceiling Assembly 1-hour rating TPC/CRP SIP Steel Roof/Ceiling Assembly 1-hour rating TPC/CRP Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 2 of 12
3 Party(s) Authorized by Manufacturer To Apply Mark: None Party(s) Authorized by Other Parties To Apply Mark: None Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 3 of 12
4 DRAWING INDEX TPC/CRP TPC/CRP TPC/CWP TPC/CWP Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 4 of 12
5 TPC/CRP Roofing and Siding Panels Composite Roof Panels Page 1 of 2 Design Number: TPC / CRP ROOF-CEILING SYSTEMS Timberline Panel Company, LLC Timberline 4½ to 10½ in. Structural Insulated Panels ASTM E Edition CAN/ULC S Edition Restricted Superimposed Load: See Item 1 Rating 1 Hour 1. CEILING ASSEMBLY: Construct a ceiling assembly using elements described in Items 2 through 5 with a maximum restricted superimposed load of 40% of the allowable capacity of the panel. 2. WOOD BEAMS/JOIST: Use minimum 4-1/2 in. wide x 9-1/2 in. deep engineered wood beam/joist spaced in accordance with manufacturer s design specifications and building code requirements. 3. CERTIFIED COMPANIES: Timberline Panel Company, LLC CERTIFIED PRODUCT: Timberline Structural Insulated Panels ROOF PANELS: Install Timberline Structural Insulated Panels consisting of the following elements: Date Revised: August 7, 2013 A. FACING: Nominal 7/16 in. thick OSB skins factory bonded to interior and exterior sides of EPS foam core (Item 3B) conforming and identified as meeting DOC PS 2-04, Exposure 1, Rated Sheathing with a span index of 24/16 and/or CAN/CSA O325.0, Exterior Grade Sheathing with a span index of 1R24/2F16. B. CORE: Use ASTM C578 compliant and Listed Type I EPS (min. 0.9 pcf) exceeding 75 and smoke-developed rating not exceeding 450 per ASTM E84 and/or CAN/ULC S701 compliant and Listed Type 1 EPS exceeding 500 per CAN/ULC S C. ADHESIVE (Not Shown): Facing materials are adhered to the core material using a structural adhesive. The adhesive is applied during the Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 5 of 12
6 TPC/CRP (page 2 of 2) Roofing and Siding Panels Composite Roof Panels Page 2 of 2 lamination procedure in accordance with the in-plant quality system documentation. D. SPLINE (Not Shown): Structural Insulated Panels are interconnected with surface splines or block splines. Surface splines typically consist of 3 in. wide by 7/16 in. thick OSB. At each panel joint, one surface spline is inserted into each of two tightfitting slots in the core. The slots in the core are located just inside the facing. Block splines are manufactured in the same manner as the SIP except with an overall thickness that is 1 in. less than the overall thickness of the panel to be joined. 4. GYPSUM BOARD: Apply two (2) layers of 5/8 in. thick, Type X gypsum board to the interior side of the ceiling assembly (Item 1) oriented with the long dimension oriented perpendicular to the wood beams (Item 2). Secure the base layer using 1-1/4 in. long, bugle head selfdrilling screws spaced nominally 8 in. on center (oc) around the perimeter and 12 in. oc in the field. Secure the second layer using 2 in. long bugle head selfdrilling screws spaced nominally 8 in. oc around the perimeter and 12 in. oc in the field. Stagger joints of base layer and second layer. A. JOINT TAPE AND COMPOUND (Not Shown) Apply a level 2 finish of vinyl or casein, dry or premixed joint compound applied in two coats to all exposed fastener heads and gypsum board joints. Embed minimum 2 in. wide paper, plastic, or fiberglass tape in first layer of compound over joints in gypsum board (Item 3). 5. ROOF COVERING (Not Shown): Use a Class A, B, or C hot mopped or cold applied roof covering, or use a ballasted, adhered or mechanically attached single ply roofing membrane. Date Revised: August 7, 2013 Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 6 of 12
7 TPC/CRP Roofing and Siding Panels Composite Roof Panels Page 1 of 2 Design Number: TPC/CRP ROOF-CEILING SYSTEMS Timberline Panel Company, LLC Timberline 4½ to 10½ in. Structural Insulated Panels ASTM E Edition CAN/ULC S Edition Rating 1 Hour Restricted Superimposed Load: See Item 1 1. CEILING ASSEMBLY: Construct ceiling assembly using the elements described in Items 2 through 6 with a maximum restricted superimposed load of 57% of the allowable capacity of the panel. 2. STEEL JOIST: Use minimum Type 10K1 open-web steel joist constructed and spaced in accordance with manufacturer s design specifications and building code requirements. 3. CERTIFIED COMPANIES: Timberline Panel Company, LLC Date Created: June 26, 2013 CERTIFIED PRODUCT: Timberline Structural Insulated Panels ROOF PANELS: Install Timberline Structural Insulated Panels consisting of the following elements: A. FACING: Nominal 7/16 in. thick OSB skins factory bonded to interior and exterior sides of EPS foam core (Item 3A) conforming and identified as meeting DOC PS 2-04, Exposure 1, Rated Sheathing with a span index of 24/16 and/or CAN/CSA Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 7 of 12
8 TPC/CRP (page 2 of 2) Roofing and Siding Panels Composite Roof Panels Page 2 of 2 O325.0, Exterior Grade Sheathing with a span index of 1R24/2F16. B. CORE: Use ASTM C578 compliant and Listed Type I EPS (min. 0.9 pcf) exceeding 75 and smoke-developed rating not exceeding 450 per ASTM E84 and/or CAN/ULC S701 compliant and Listed Type 1 EPS exceeding 500 per CAN/ULC S C. ADHESIVE (Not Shown): Facing materials are adhered to the core material using a structural adhesive. The adhesive is applied during the lamination procedure in accordance with the in-plant quality system documentation. D. SPLINE: Structural Insulated Panels are interconnected with surface splines or block splines. Surface splines typically consist of 3 in. wide by 7/16 in. thick OSB. At each panel joint, one surface spline is inserted into each of two tightfitting slots in the core. The slots in the core are located just inside the facing. Block splines are manufactured in the same manner as the SIP except with an overall thickness that is 1 in. less than the overall thickness of the panel to be joined. spray applied fiber (CAFCO BLAZE- SHIELD Type DC-F) to the metal lath (Item 6). Apply at a minimum thickness of 2-1/4 in. to all mesh surfaces. Please reference the CAFCO BLAZE-SHIELD Type DC-F Code Evaluation Report for more details. 6. ROOF COVERING (Not Shown): Use a Class A, B, or C hot mopped or cold applied roof covering, or use a ballasted, adhered or mechanically attached single ply roofing membrane. 4. METAL LATH: Install 3/8 in. expanded galvanized steel mesh weighing 3.4 lb/yd. to cover the exposed side of the steel joist (Item 2). Secure the lath using No. 20 SWG steel tie wire at the midpoint of alternate web members. Install the lath on the bottom of the roof panels (Item 3) using 1-1/2 in. deep x 15/16 in. wide C-pint staples spaced 7 in. on center (oc). 5. SPRAY APPLIED FIBER: Apply to the wetted surfaces of steel joist and panels, a minimum 11 pcf dry density Listed Date Created: June 26, 2013 Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 8 of 12
9 TPC/CWP Wall Panels Composite Wall Panels Page 1 of 2 Design Number: TPC/CWP EXTERIOR WALL SYSTEMS Timberline Panel Company, LLC Timberline 4½, 6½ or 8¼ in. Structural Insulated Panels ASTM E Edition CAN/ULC S Edition Rating 1 Hour Restricted Superimposed Load: See Item 1 1. WALL ASSEMBLY: Construct a wall assembly using elements described in Items 2 through 4 up to a maximum of 9 feet in height with a maximum restricted superimposed load of 82% of the allowable capacity of the panel. 2. CERTIFIED COMPANIES: Timberline Panel Company, LLC Date Created: August 7, 2013 CERTIFIED PRODUCT: Timberline Structural Insulated Panels WALL PANELS: Install Timberline Structural Insulated Panels consisting of the following elements: A. FACING: Nominal 7/16 in. thick OSB skins factory bonded to interior and exterior sides of EPS foam core Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 9 of 12
10 TPC/CWP (page 2 of 2) Wall Panels Composite Wall Panels Page 2 of 2 (Item 2B) conforming and identified as meeting DOC PS 2-04, Exposure 1, Rated Sheathing with a span index of 24/16 and/or CAN/CSA O325.0, Exterior Grade Sheathing with a span index of 1R24/2F16. B. CORE: Use ASTM C578 compliant and Listed Type I EPS (min. 0.9 pcf) exceeding 75 and smoke-developed rating not exceeding 450 per ASTM E84 and/or CAN/ULC S701 compliant and Listed Type 1 EPS exceeding 500 per CAN/ULC S C. ADHESIVE (Not Shown): Facing materials are adhered to the core material using a structural adhesive. The adhesive is applied during the lamination procedure in accordance with the in-plant quality system documentation. D. SPLINE (Not Shown): Structural Insulated Panels are interconnected with surface splines or block splines. Surface splines typically consist of 3 in. wide by 7/16 in. thick OSB. At each panel joint, one surface spline is inserted into each of two tightfitting slots in the core. The slots in the core are located just inside the facing. Block splines are manufactured in the same manner as the SIP except with an overall thickness that is 1 in. less than the overall thickness of the panel to be joined. 3. GYPSUM BOARD: Apply two (2) layers of 5/8 in. thick, Type X gypsum board to the interior and exterior side of the wall assembly (Item 1) oriented vertically with the joints staggered 16 in. on center (oc). Secure the base layer using 1-5/8 in. long, bugle head self-drilling screws spaced nominally 12 in. oc around the perimeter and 24 in. oc in the field. Secure the second layer using 2 in. long bugle head self-drilling screws spaced nominally 12 in. oc around the perimeter and 24 in. oc in the field. Date Created: August 7, 2013 A. JOINT TAPE AND COMPOUND (Not Shown) Apply a level 2 finish of vinyl or casein, dry or premixed joint compound applied in two coats to all exposed fastener heads and gypsum board joints. Embed minimum 2 in. wide paper, plastic, or fiberglass tape in first layer of compound over joints in gypsum board (Item 3). 4. BEARING PLATES (Not Shown): Install nominal No. 2 lumber plates to the top and bottom of the wall panels (Item 2) in the pre-cut channel in the foam core covering the entire surface area and secure to the skins (Item 2A) using 8d common nails spaced nominal 6 in. oc. Prior to installing, apply a layer of acrylic latex caulk across the mating face with the EPS foam core (Item 2B). Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 10 of 12
11 TPC/CWP Wall Panels Composite Wall Panels Page 1 of 2 Design Number: TPC / CWP EXTERIOR WALL SYSTEMS Timberline Panel Company, LLC Timberline 6½ in. Structural Insulated Panels ASTM E Edition CAN/ULC S Edition Rating 1 Hour Restricted Superimposed Load: See Item 1 1. WALL ASSEMBLY: Construct a wall assembly using elements described in Items 2 through 4 up to a maximum of 10 feet in height with a maximum restricted superimposed load of 60% of the allowable capacity of the panel. 2. CERTIFIED COMPANIES: Timberline Panel Company, LLC Date Created: August 7, 2013 CERTIFIED PRODUCT: Timberline Structural Insulated Panels WALL PANELS: Install Timberline Structural Insulated Panels consisting of the following elements: A. FACING: Nominal 7/16 in. thick OSB skins factory bonded to interior and exterior sides of EPS foam core Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 11 of 12
12 TPC/CWP (page 2 of 2) Wall Panels Composite Wall Panels Page 2 of 2 (Item 2B) conforming and identified as meeting DOC PS 2-04, Exposure 1, Rated Sheathing with a span index of 24/16 and/or CAN/CSA O325.0, Exterior Grade Sheathing with a span index of 1R24/2F16. B. CORE: Use ASTM C578 compliant and Listed Type I EPS (min. 0.9 pcf) exceeding 75 and smoke-developed rating not exceeding 450 per ASTM E84 and/or CAN/ULC S701 compliant and Listed Type 1 EPS exceeding 500 per CAN/ULC S C. ADHESIVE (Not Shown): Facing materials are adhered to the core material using a structural adhesive. The adhesive is applied during the lamination procedure in accordance with the in-plant quality system documentation. D. SPLINE (Not Shown): Structural Insulated Panels are interconnected with surface splines or block splines. Surface splines typically consist of 3 in. wide by 7/16 in. thick OSB. At each panel joint, one surface spline is inserted into each of two tightfitting slots in the core. The slots in the core are located just inside the facing. Block splines are manufactured in the same manner as the SIP except with an overall thickness that is 1 in. less than the overall thickness of the panel to be joined. 3. GYPSUM BOARD: Apply one (1) layer of 5/8 in. thick, Listed Type C gypsum board to the interior and exterior side of the wall assembly (Item 1) oriented vertically. Secure the gypsum board using 1-5/8 in. long, bugle head selfdrilling screws spaced nominally 8 in. on center (oc) around the perimeter and 12 in. oc in the field. A. JOINT TAPE AND COMPOUND (Not Shown) Apply a level 2 finish of vinyl or casein, dry or premixed joint Date Created: August 7, 2013 compound applied in two coats to all exposed fastener heads and gypsum board joints. Embed minimum 2 in. wide paper, plastic, or fiberglass tape in first layer of compound over joints in gypsum board (Item 3). 4. STUDS AND BEARING PLATES: Install nominal 2 in. x 6 in. No. 2 lumber plates to the top and bottom of the wall panels (Item 2) in the pre-cut channel in the foam core and secure to the skins (Item 2A) using 8d common nails spaced nominal 6 in. oc. Prior to installing, apply a layer of acrylic latex caulk across the mating face with the EPS foam core (Item 2B). Timberline Panel Company, LLC Rev: Mar :46AM Uncontrolled Copy Page 12 of 12
The better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 83 SHOP APPLIED WOOD COATINGS SECTION: 06 16 00 SHEATHING REPORT HOLDER:
0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1365 Reissued 04/2016 This report is subject to renewal 04/2017. DIVISION: 06 00 00 WOOD, PLASTICS
ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.
ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3493 Reissued September 2014 This report is subject to renewal September 2015. A Subsidiary of the International Code Council DIVISION:
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.
0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-1826 Reissued 02/2016 This report is subject to renewal 02/2018. DIVISION: 07 00 00 THERMAL
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council RETAINED ON U.S.
ICC-ES Legacy Report ER-5043* Reissued March 2004 www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code DIVISION: 09
Gypsum Board Systems Manual
CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3
Design No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)
Design No. P736 September 26, 2003 Restrained Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Beam Ratings 1, 1-1/2 or 2 Hr (See Items 7 and 8A) 1. Beam
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
H-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing
Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Specifications for SURE-BOARD Series 200 and 200W Panel for shear PART 1.0 GENERAL 1.01
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
MASTERFORMAT SPECIFICATION
Insulspan, Incorporated 9012 East US 223 Blissfield, MI, USA 49228-0026 Phone: 800.726.3510 Insulspan Division of Plasti-Fab Ltd. 600 Chester Road Deltas, BC, Canada V3M 5Y3 Phone: 866.848.8855 www.insulspan.com
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Electrical Wiring Technical Bulletin
Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam
Discipline: Structural Issued 04-26-06
California Department of General Services. Division of the State Architect. Product Acceptance Report STRUCTURAL SHEAR PANEL SURE-BOARD SERIES 200 PANELS PA-132 Discipline: Structural Issued 04-26-06 This
B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
LP OSB Sheathing & Structural 1 Sheathing
Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48
Fire Resistance of Brick Masonry
TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Fire Resistance of Brick Masonry 16 March 2008 Abstract: This Technical Note presents
REPORT NUMBER: 100900226COQ-003 ORIGINAL ISSUE DATE: July 19, 2013
REPORT NUMBER: 100900226COQ-003 ORIGINAL ISSUE DATE: July 19, 2013 TEST REPORT EVALUATION CENTER INTERTEK TESTING SERVICES NA LTD. 1500 BRIGANTINE DRIVE COQUITLAM, BC V3K 7C1 CANADA RENDERED TO PHOENIX
SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.
SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.
ICC-ES Evaluation Report ESR-2270 Reissued September, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels (06 12 16)
PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels (06 12 16) Report Holder Structural Insulated Panel Association (SIPA) PO Box 1699 Gig Harbor, WA
GYPSUM BOARD AND PLASTER
CHAPTER 25 GYPSUM BOARD AND PLASTER SECTION 2501 GENERAL 2501.1 Scope. 2501.1.1 General. Provisions of this chapter shall govern the materials, design, construction and quality of gypsum board, lath, gypsum
Design No. L556. Design No. L556
1 of 9 3/17/2015 6:15 PM Design No. L556 BXUV.L556 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted
CertainTeed. Shaftliner For A rea Separation Firewalls
CertainTeed Shaftliner For A rea Separation Firewalls M2Tech Shaftliner Type X for Area Separation M2Tech Shaftliner is a specially formulated product for applications where enhanced mold resistance is
THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.
ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL"
Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL" Design/System/Construction/Assembly Usage Disclaimer Authorities
Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions
Y Parts Included: Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions Tools Required: Power Driver Drill Bit (Determined by fastener) Driver Bit (Determined by fastener)
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES
1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
How to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof. 1155 & 4155 LCL: Applies to all freight in less than container load quantities.
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards
GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
B. Related categories: The following categories contain requirements that relate to this section:
ORIENTED STRAND BOARD PART I. - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply
SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC #100-2949-1 TESTED: MAY 23, 2008 REVISION
SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC #100-2949-1 TESTED: MAY 23, 2008 REVISION 2.0: OCTOBER 14, 2008 October 14, 2008 Client: Attn: Subject:
Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.
BULLETIN No. 28 (a) Fire Protection CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8 Floor Assembly No. NRC764-FF22 Fire Endurance Period 1 74 minutes Sound
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010
Best Barns USA Assembly Book Revised November 29, 2010 SAMPLE INSTRUCTIONS the Denver 12'x 12' or 12'x16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775
CHAPTER 6 CONSTRUCTION TYPES
CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
5.0 wall ApplicAtions
5.0 Wall Applications 5.1 Below Grade Walls Properly reinforced Arxx ICFs with a nominal concrete core width of 6 (150 mm) are demonstrably more resistant to lateral earth pressures than 8 (200 mm) plain
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
FIRE-RESISTANCE RATINGS WITH STEEL JOISTS
FIRE-RESISTANCE RATINGS WITH STEEL JOISTS The Underwriters Laboratories (U.L.) Fire Resistance Directory lists hundreds of assemblies their fire resistance ratings. The Specifying Professional can choose
Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS
INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.
CPA Steel Stud Framing Page 1 of 11
CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#
To learn more about PATH, please contact:
PATH (Partnership for Advancing Technology in Housing) is a new private/public effort to develop, demonstrate, and gain widespread market acceptance for the Next Generation of American housing. Through
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**
PHRC Webinar Series Tuesday, September 9, 2014 1:00 pm Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** Presented by: Bryan Heitzmann Credit(s) earned on completion of
R-Value and Densities Chart
R-Value and Densities Chart Material R-Value Per Inch R-Value Per Unit Inside Air Film 0.68 Air Space between Studs 0.95 Building Pa 0.06 ½ in. Fiberboard Sheathing 1.52 Gypsum Wallboard or Drywall 0.90
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
Post and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
Creep Behavior of Structural Insulated Panels (SIPs)
Creep Behavior of Structural Insulated Panels (SIPs) Results from a Pilot Study Dwight McDonald Marshall Begel C. Adam Senalik Robert J. Ross Thomas D. Skaggs Borjen Yeh Thomas Williamson United States
Additions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
DEFAULT HEAT LOSS COEFFICIENTS
DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables
GYPSUM BOARD Guide Specification. National Gypsum Company SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 SECTION INCLUDES
GYPSUM BOARD Guide Specification (Specifier Note: The purpose of this guide specification language is to assist the specifier in correctly specifying gypsum board products and their installation. The specifier
EcoTouch Insulation with PureFiber Technology
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Lightweight Partition Design for Residential and Commercial Buildings
Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation
TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. www.r-control.com CONTROL, NOT COMPROMISE.
R-CONTROL s STRUCTURAL INSULATED PANELS Note: Information deemed reliable at time of printing. Please visit www.r-control.com for latest information. June 2012 CONTROL, NOT COMPROMISE. www.r-control.com
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction
CertainTeed. For Shaftwalls SHAFTLINER
CertainTeed For Shaftwalls SHAFTLINER GlasRoc Shaftliner is a paperless mold and moisture resistant gypsum board combining reinforcing glass mats and a specially formulated fire and moisture resistive,
necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS
UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS Executive Summary: There is a proposal at the Joint Committee on Administrative
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
Building Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
SIMPLE SAVER SYSTEM DESIGN MANUAL
SECTION 5: BAR JOIST CONSTRUCTION DETAILS SIMPLE SAVER SYSTEM DESIGN MANUAL Call Toll-free: 1-800-255-0776 Fax: 1-402-454-2708 E-mail us at: [email protected] SIMPLE SAVER SYSTEM DESIGN MANUAL