0331 Brick and block construction



Similar documents
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

LAYING BLOCK AND BRICK

COMMONLY USED RESIDENTIAL BUILDING CODES

Chapter 2 Basis of design and materials

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Residential Inspection Guidelines

NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE

EAST LYME HIGH SCHOOL

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

If stepping is required, step at 180mm as seen in this picture.

The WANZ Guide to Window Installation

State of Connecticut Department of Public Health RADON PROGRAM

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

Brick Veneer Construction

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Certification: Building Plans Examiner. Exam ID: B3

Excerpts from the Canadian National Building Code (NBC)

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

Timber Decks. Technical Note. March 2007

Chapter 3 Pre-Installation, Foundations and Piers

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Installation An Industry Guide to the Correct Installation of Windows and Doors

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

The WANZ Guide to Window Installation

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Sun Windows General Information Sun New Construction Window Installation Instructions

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Superform Products Ltd.

Ver. 2. Guide to. Inspecting Residential Brick Veneer

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

6 RETROFITTING POST & PIER HOUSES

PANELIZED HOME INSTALLATION GUIDELINE

K2 STONE NATURAL VENEER

Section EXTERIOR STONE VENEER Full Mortar

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

INSTALLATION OF A BAY WINDOW

Part 5 STRUCTURAL MASONRY

March 14, Installation of Bay, Bow and Garden Windows

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

How to build a Pizza Oven in 4 days

The Full Brick Manual

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Window Installation Instructions

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Coursing Tables, Metric Shapes and Sizes

Ceramic Glazed Brick Exterior Walls

Chapter. Restoration of Damaged Structures

Natural Thin Stone Veneer

Manufactured Stone Veneer Installation Instructions

Connex. Mortarless Masonry Block System

The minimum reinforcement for the stem wall is the placement of:

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

Ubiflex. Non-lead flashing system

Technical Notes 3B - Brick Masonry Section Properties May 1993

12.1 Schlüter -KERDI-BOARD

CHAPTER 6 CONSTRUCTION TYPES

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

3 Masonry and Manufactured Stone (Interior and Exterior)

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

GUIDELINES FOR SITE & HOUSE INSPECTION

Hanson Building Products. precast basement solutions

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Adding Brick Veneer to Existing Construction

Residential Deck Safety, Construction, and Repair

CHAPTER NO. 27 QUANTITIES OF MATERIALS

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Energy Company Obligation (ECO): Technical Monitoring Questions

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

Exterior Elevated Elements Inspection Guidelines

FORM DESIGN. easy to work with, and generally available.

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

How To Prevent Water From Getting In A Building

1850 Centennial Park Drive, Reston, Virginia

Brick Veneer/Steel Stud Walls

Installation Window Building In Details

CHIMNEYS AND FIREPLACES

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Transcription:

0331 BRICK AND BLOCK CONSTRUCTION This worksection has been written for Class 1 and 10a buildings that fully conform to the scope of AS 4773.1. If the works include isolated structures, (totally separate from the main conforming building), that do not conform to the scope of AS 4773.1, include the references to AS 3700 as noted in Guidance. If the buildings do not conform to the scope of AS 4773.1 delete all references to AS 4773.1 in the specification and change the specification to references AS 3700, as noted in the Guidance. Retaining walls: Consult the local approval authority to determine where walls over a certain height require design by a professional engineer. Energy efficiency requirements at BCA 2.6 set out minimum insulation performance requirements for walls, roofs, floor slabs and external glazing depending on climate zone and orientation. 1 GENERAL 1.1 STANDARDS Materials and construction: To AS 4773.1 and AS 4773.2. For isolated structures not conforming to the scope of AS 4773 series amend to AS 3700. 2 PRODUCTS 2.1 DURABILITY Exposure environment: [complete/delete] Select exposure environment from: mild, moderate, industrial, marine or severe marine to AS 4773.1 clause 4.3. Exposure environment is project specific and applies to all masonry materials, accessories and built-in items. Exposure locations: To AS 4773.1 clause 4.4. There might be different exposure locations within one project: exterior, exterior-coated or interior. Nominate in SELECTIONS or show in the drawings. For isolated structures not conforming to the scope of AS 4773 series amend to AS 3700 clause 5.4. 2.2 MATERIALS Bricks and blocks Standard: To AS/NZS 4455.1 and AS/NZS 4455.3. Minimum age of clay bricks: 7 days. Salt attack resistance grade: To AS 4773.2 Table 2.1. For isolated structures not conforming to the scope of AS 4773 series amend to AS 3700 Table 5.1. Problems are being experienced with salt attack on brickwork below damp-proof course level on sites which had once been heavily fertilised. Exposure class bricks are normally readily available for such locations. Mortar materials Sand: Fine aggregate with a low clay content and free from efflorescing salts, selected for colour and grading. Proportions: To AS 4773.1 Table 3.1 2.3 BUILT-IN COMPONENTS Durability class of built-in components: To AS 4773.1 Table 4.1. For isolated structures not conforming to the scope of AS 4773 series amend to AS 3700 Table 5.1. Steel lintels Angles and flats: Sizes to AS 4773.1 Table 12.1. Cold-formed lintels: Designed to AS/NZS 4600. Corrosion protection: To AS/NZS 2699.3. Galvanizing: Do not cut after galvanizing. NATSPEC DOMESTIC 46 "[insert date]"

Wall ties Standard: To AS/NZS 2699.1. Type: A. Corrosion protection: To AS/NZS 2699.1. Connectors and accessories Standard: To AS/NZS 2699.2. Corrosion protection: To AS/NZS 2699.2. Flashings and damp-proof courses Standard: To AS/NZS 2904. For suitable flashings and DCP material see AS 4773.2 Table 5.2. 3 EXECUTION 3.1 GENERAL Mortar mixing : Measure volumes accurately to the documented proportions. Machine mix for at least six minutes. Protection from contamination : Protect masonry materials and components from ground moisture and contamination. Bond Type: Stretcher bond. Building in Embedded items: Build in wall ties and accessories as the construction proceeds. If it is not practicable to obtain the required embedment wholly in the mortar joint in hollow masonry units, fill appropriate cores with grout or mortar. Clearance for timber frame shrinkage : In timber frame brick veneer construction, leave clearances between window frames and brick sill and between roof frames and the brick veneer as follows: - Additional clearance: Accommodate additional shrinkage of unseasoned floor timbers. - Single storey frames and ground floor windows (not for slab on ground): 10 mm. - Two storey frames and upper floor windows: 20 mm. Joining to existing : Provide a control joint where joining to existing structures. Do not tooth new masonry into existing work unless approved by a professional engineer. Mortar Joints Solid and cored units: Lay on a full bed of mortar. Fill perpends solid. Cut mortar flush. Face-shell bedded hollow units: Fill perpends solid. Cut mortar flush. Finish: Conform to the following: - Externally: Tool to give a dense water-shedding finish. - Internally: If wall is to be plastered, do not rake more than 10 mm to give a key. - Thickness: 10 mm. Cutting: Set out masonry with joints of uniform width and the minimum of cutting of masonry units. For jointing, see AS 4773.1 clause 14.2 Mortar joints. Mortar joints are normally tooled, weatherstruck or raked. Mortar joints which are not completely filled and tooled may not provide adequate weatherproofing. A flush joint which is cut with the trowel without compacting the mortar should not be used externally unless agreed. Rate of construction : Regulate the rate of construction to eliminate joint deformation, slumping or instability. Rods Set out: Construct masonry to the following rods: - 75 mm high units: 7 courses to 600 mm. NATSPEC DOMESTIC 47 "[insert date]"

- 90 mm high units: 6 courses to 600 mm. - 190 mm high units: 3 courses to 600 mm. 3.2 FACEWORK Cleaning : Clean progressively as the work proceeds to remove mortar smears, stains and discolouration. Do not erode joints if using pressure spraying. Acid solution: Do not use. Colour mixing Distribution: In facework, distribute the colour range of units evenly to prevent colour concentrations and banding. Sills and thresholds : Solidly bed sills and thresholds and lay them with the top surfaces drain away from the building. Minimum size of unit: Three quarters full width. 3.3 SUBFLOOR WORK Bearer piers Provide engaged or free standing unreinforced masonry piers to support bearers at 1800 mm maximum centres and to the Bearer pier table. Bearer pier table Type Minimum size (mm) Engaged 230 x 110 bonded or tied to walls Freestanding up to 1500 mm high 230 x 230 Freestanding 1500 to 2700 mm high 350 x 350 Access openings : In internal walls, leave door-width openings beneath doorways to give access to underfloor areas. Air vent location : Provide air vents to give adequate cross ventilation to the space under suspended ground floors. For subfloor ventilation, BCA 3.4.1 and AS 4773.2 clause 6.2 provides minimum requirements for various climates. See AS 3959 for buildings in bushfire prone areas; vents require a corrosion resistant wire mesh to prevent ingress of embers. Cavity walls: Provide matching vents in the internal leaves located as near as practicable to the air vents in the external leaves. Location: Below damp-proof course to internal and external walls. Minimum provision: 6000 mm 2 net ventilation area per linear metre of wall. The area for ventilation of 6000 mm 2 per linear metre of wall is based on the acceptable construction practice in BCA Table 3.4.1.2. Underpinning Requirement: Install underpinning while maintaining the building undamaged. Grouting: Pack dry mix M4 mortar between underpinning and existing structure within 24 and 48 hours of completion of each panel of underpinning. Confirm with the structural engineer and amend as required. 3.4 CAVITY WORK Cavity clearance : Keep cavities clear at all times. Cavity fill : Fill the cavity with mortar to 1 course above adjacent finished (ground) level. Fall the top surface towards the outer leaf. NATSPEC DOMESTIC 48 "[insert date]"

Cavity width : Provide minimum cavity widths in conformance with the following: - Masonry walls: 50 mm. - Masonry veneer walls: 40 mm between the masonry leaf and the loadbearing frame and 25 mm minimum between the masonry leaf and sheet bracing. Width of cavity may need to be increased if wall insulation is required to BCA 3.12.1.4. Openings Do not close the cavity at the jambs of external openings. Wall ties connectors and accessories Protection: Install to prevent water passing across the cavity. 3.5 DAMP-PROOF COURSES Location : Provide damp-proof courses as follows: - Timber floors: In the first course below the level of the underside of ground floor timbers in internal walls and inner leaves of cavity walls. - Cavity walls built off slabs on ground: In the bottom course of the outer leaf, continuous horizontally across the cavity and up the inner face bedded in mortar, turned 30 mm into the inner leaf 1 course above. - Masonry veneer construction: In the bottom course of the outer leaf, continuous horizontally across the cavity. Fastened to the inner frame 75 mm above floor level. - Walls adjoining infill floor slabs on membranes: In the course above the underside of the slab in internal walls and inner leaves of cavity walls. Project 40 mm and dress down over the membrane turned up against the wall. Height: Not less than: - 150 mm above the adjacent finished ground level. - 75 mm above the finished paved or concrete area. - 50 mm above the finished paved or concreted area and protected from the direct effect of the weather. : Lay in long lengths. Lap the full width of angles and intersections and 150 mm at joints. Step as necessary, but not more than 2 courses per step for brickwork and 1 course per step for blockwork. Sandwich damp-proof courses between mortar. Junctions: Preserve continuity of damp-proofing at junctions of damp-proof courses and waterproof membranes. 3.6 FLASHINGS See also Roofing for roof flashings. Location : Provide flashings as follows: - Floors: Full width of outer leaf immediately above slab, continuous across cavity and up the inner face bedded in mortar, turned 30 mm into the inner leaf 2 courses above for brick and 1 course for block. If the slab supports the outer skin and is not rebated, bed the flashing in a suitable sealant. - Under sills: 30 mm into the outer leaf bed joint 1 course below the sill, extending up across the cavity and under the sill in the inner leaf or the frame. Extend at least 150 mm beyond the reveals on each side of the opening. - Over lintels to openings: Full width of outer leaf immediately above the lintel, continuous across cavity, turned 30 mm into the inner leaf 2 courses above for brick and 1 course for block or turned up against the frame and fastened to it. Extend at least 150 mm beyond the ends of the lintels. - At abutments with structural frames or supports: Vertical flash in the cavity from 150 mm wide material, wedged and grouted into a groove in the frame opposite the cavity. - At jambs: Vertically flash jamb extending 75 mm into the cavity, interleaved with the sill and head flashing at each end. Fix to jambs. NATSPEC DOMESTIC 49 "[insert date]"

- At roof abutments with cavity walls: Cavity flash immediately above the roof and over-flash the roof apron flashing. Any significant interruption of the cavity, including at conduits, should be flashed. Head and sill flashings should not be taut across the cavity and threshold flashings should be bedded in mortar to run vertically and horizontally, not diagonally. : Sandwich flashings between mortar except where on lintels. Pointing: Point up joints around flashings to fill voids. Weepholes See AS 3700 clauses 4.7.2 Prevention of moisture penetration - Weepholes and 11.4.14 Workmanship - Weepholes. Preferably indicate location and detail on the drawings, and delete this subclause. See AS 3959 for building in bushfire prone areas; weep holes require a corrosion resistant wire mesh to prevent ingress of embers. Location: Provide weepholes to external leaves of cavity walls in the course immediately above flashings, and cavity fill, and at the bottoms of unfilled cavities. Form: Open perpends. Maximum spacing: 1200 mm. Weephole guards: Provide access barrier. - Type: [complete/delete] 3.7 WALL TIES Location Spacing: To AS 4773.2 clause 9.7 and clause 10.6. Embedment: At least 50 mm into mortar ensuring that mortar cover is 15 mm minimum to the outside face of the mortar. 3.8 CONTROL JOINTS Location and spacing: Provide contraction joints, expansion joints and articulation joints to AS 4773.2 Section 7. Control joint filling : Clean the joints thoroughly and insert an easily compressible backing material before sealing. Sealant depth: Fill the joints with a gun-applied flexible sealant for a depth of at least two-thirds the joint width. Sealant type: External: UV stable. Flexible masonry ties Requirement: Provide stabilising ties at control joints and abutting structural elements, including columns, beams and slab soffits. 3.9 REINFORCED AND GROUTED BLOCKWORK Reinforced blockwork should be specified by a professional engineer. Cleaning core holes : Provide purpose-made cleanout blocks or machine cut a cleaning hole at the base of each grouted core. Location: Locate on the side of the wall which is to be rendered or otherwise concealed. Cleaning: Rod cores to dislodge mortar fins protruding from the blocks and mortar droppings from reinforcement. Remove through the clean-out blocks. Grouting Commencement: Do not commence until grout spaces have been cleaned out and the mortar joints have attained sufficient strength to resist blow-outs. Height of lift: Limit the height of individual lifts in any pour to make sure that the grout can be thoroughly compacted to fill all voids. Compaction: Compact by vibration or by rodding. NATSPEC DOMESTIC 50 "[insert date]"

Topping up: On the completion of the last lift, top up the grout after 10 min to 30 min, and vibrate or rod to mix with the previous pour. 3.10 LINTELS : Do not cut on site. Keep lintels 10 mm clear of heads of frames. Steel lintels: Pack mortar between any vertical component and supported masonry units. For angles install with the long leg vertical. Propping: Provide temporary props to lintels to prevent deflection or rotation. 3.11 BAGGING Preparation : Cut joints flush before bagging. Dry bagging Application: Apply laying mortar to the surface using a hessian bag or similar. Flush up irregularities, but leave a minimum amount of mortar on the surface. 4 SELECTIONS 4.1 SCHEDULES Brick and block construction schedule Property Bricks and blocks Type Manufacturer Work size Sill units Colour Feature colour Mortar Type Colour Units joints Shape or profile Code A B C Bricks and blocks Type: Clay, concrete, or calcium silicate bricks. Concrete or AAC blocks. Work size: Commonly 230 x 110 x 76 mm for bricks and 390 x 190 x 190 mm for blocks. Mortar Type: Nominate for exposure condition and type of masonry unit. Colour: Classified as grey cement, off-white cement or others. Joints Joints: Select mortar joints as tooled, raked, weatherstruck or others. NATSPEC DOMESTIC 51 "[insert date]"