SARNAFIL WATERPROOFING MEMBRANES SARNAFIL ADHERED ROOF WATERPROOFING MEMBRANES



Similar documents
ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

FATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS

Product. Regulations. Agrément Certificate No 08/4531. Designated by Government to issue European Technical Approvals

TECHNOELAST ROOF WATERPROOFING MEMBRANES TECHNOELAST APP EPP AND TECHNOELAST APP EKP ROOF WATERPROOFING MEMBRANES

BAUDER BITUMINOUS ROOFING SYSTEMS BAUDERFLEX ROOF WATERPROOFING SYSTEMS

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES

ICOPAL POUR AND ROLL ROOF WATERPROOFING ICOPAL POWER ELASTOMERIC ROOF WATERPROOFING SYSTEM

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

FLAGON PVC SINGLE-PLY ROOF WATERPROOFING SYSTEMS FLAGON SFc, SFb AND SV ROOF WATERPROOFING SYSTEMS

LANGLEY S ROOF WATERPROOFING MEMBRANES PARADIENE/PARAFOR ROOF WATERPROOFING SYSTEMS

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

RHEPANOL RHEPANOL FK ROOF COVERING SYSTEM

AXTER ROOF WATERPROOFING MEMBRANES EXCEL ROOF SYSTEM

DE BOER WATERPROOFING MEMBRANES

POLYGLASS ROOF WATERPROOFING MEMBRANES POLYSHIELD ROOF WATERPROOFING MEMBRANES

RENOLIT ROOF WATERPROOFING MEMBRANES ALKORPLAN ROOF WATERPROOFING MEMBRANES

Regulations Detail Sheet 1

SIKA BRIDGE DECK WATERPROOFING SYSTEM SIKALASTIC -851 BRIDGE DECK WATERPROOFING SYSTEM

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

ALWITRA ROOFING MEMBRANES EVALON AND EVALON V ROOFING SHEETS

SARNAFIL MECHANICALLY FASTENED ROOF WATERPROOFING SYSTEMS Système d étanchéité Dachabdichtungen. Regulations

Casali SpA Industria Chimica Bituminosa

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)

Polymeric membrane for roof waterproofing

PERMATEC HOT-APPLIED MONOLITHIC ROOFING AND WATERPROOFING SYSTEMS PERMATEC ECO-WRAP AND PERMATEC ANTI-ROOT HOT-APPLIED MONOLITHIC MEMBRANE

PRODUCT SHEET 1 COLD FUSION BONDED BUILT-UP ROOFING SYSTEMS

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

MAXFLOW DRAINAGE SYSTEM MAXFLOW SYPHONIC DRAINAGE SYSTEM

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

METROTILE ROOFING SYSTEM METROTILE SHINGLE

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

DULUX MASONRY PAINTS DULUX TRADE WEATHERSHIELD SMOOTH MASONRY PAINT

HUNTON BITUMEN IMPREGNATED BOARDS HUNTON BITROC SHEATHING BOARD

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

SIG SIG CAVITY WALL INSULATION

MAXFLOW SYPHONIC DRAINAGE SYSTEM

STIRLING LLOYD BRIDGEDECK WATERPROOFING SYSTEM ELIMINATOR (TWO COAT) BRIDGEDECK WATERPROOFING SYSTEM

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Product. Regulations. Agrément Certificate No 06/4388. Designated by Government to issue European Technical Approvals

Building Owners Guide to a Duro-Last System!

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

BDA Agrément BAR /02/A

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

INSTA-POLYPEARL CAVITY WALL INSULATION INSTA-POLYPEARL PLUS AND INSTA-POLYPEARL PLATINUM CAVITY WALL INSULATION

PREMARK CRACK SEALING SYSTEMS FOR HIGHWAYS PREMARK ANTI-SKID OVERBANDING SYSTEM

ITEM THERMOPLASTIC MEMBRANE ROOFING

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

Energy Company Obligation (ECO): Technical Monitoring Questions

WATERPROOFING FOR CONCRETE STRUCTURES

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS

SikaProof A Technology

Including. Rubershield-Pro. Breather Membrane

Peel & Seal Self-Stick Roofing Solutions

DENSO WATERPROOFING SYSTEMS

Asphalt Shingle Application Requirements

CHAPTER 7: Building Systems ROOFING SYSTEMS

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

DOMESTIC & GENERAL INSULATION LTD BLOWN-IN CAVITY WALL INSULATION THERMABEAD, THERMABEAD CARBON SAVER AND THERMABEAD DIAMOND CWI

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

MARLEY ETERNIT CLADDING PANELS CEDRAL WEATHERBOARD

European Technical Approval ETA 12/0419

Agrément Certificate 06/4300 Product Sheet 1

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

INSTABEAD CAVITY WALL INSULATION SYSTEM INSTABEAD WHITE, INSTABEAD CARBON SAVER AND INSTABEAD DIAMOND CAVITY WALL INSULATION

COMMERCIAL BUILDING APPLICATIONS

synthetic waterproofing systems

Roofing Systems. New Applications / Re-Roofing / Maintenance

THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center

Bituminous Sheet Flat Roofs: Their repair and maintenance

KALZIP STANDING SEAM ROOF SYSTEMS KALZIP DECK ROOF SYSTEM

Division 9. SignaFlor Pad and Pour Flooring System

SIKA WATERPROOFING SYSTEMS SIKA-1 WATERPROOFING SYSTEMS

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

A. Roofing Terminology: Definitions in ASTM D 1079 and glossary in NRCA's "The NRCA Roofing and Waterproofing Manual" apply to work of this Section.

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

AND MEMBRANES ROOFING UNDERLAYS.

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Please read the entire document before purchasing and installing any of these products

Multi-layer Insulation Blanket for Roofs

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

BLACK JACK ALL WEATHER ROOF COATING

How to repair your existing low slope flat roof.

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

RECOATING AND RENEWING SPF ROOFING SYSTEMS

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

WATERPROOFING SikaProof -A TECHNOLOGY

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Roofers Guide to Underslating Membranes

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

SECTION THERMOPLASTIC MEMBRANE ROOFING

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

Transcription:

Sika Limited Target Market Roofing Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: sarnafilroofing@uk.sika.com website: www.sarnafil.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate 08/4531 Product Sheet 1 SARNAFIL WATERPROOFING MEMBRANES SARNAFIL ADHERED ROOF WATERPROOFING MEMBRANES This Agrément Certificate Product Sheet (1) relates to Sarnafil Adhered Roof Waterproofing Membranes, comprising single-ply polymeric sheets for use on flat or pitched roofs with limited access. (1) Hereinafter referred to as Certificate. CERTIFICATION INCLUDES: factors relating to compliance with Building Regulations where applicable factors relating to additional non-regulatory information where applicable independently verified technical specification assessment criteria and technical investigations design considerations installation guidance regular surveillance of production formal three-yearly review. KEY FACTORS ASSESSED Weathertightness the membranes will resist the passage of moisture into the building (see section 6). Properties in relation to fire the membranes can enable a roof to be unrestricted under the Building Regulations (see section 7). Resistance to wind uplift the membranes will resist the effects of any wind suction acting on the roof (see section 8). Resistance to foot traffic the membranes will accept the limited foot traffic and loads associated with installation and maintenance (see section 9). Durability under normal service conditions the Sarnafil G410 and Sarnafil TG76 membranes will provide durable roof waterproofings with service lives in excess of 35 and 25 years respectively (see section 11). The BBA has awarded this Certificate to the company named above for the products described herein. These products have been assessed by the BBA as being fit for their intended use provided they are installed, used and maintained as set out in this Certificate. On behalf of the British Board of Agrément Date of Fourth issue: 24 May 2016 John Albon Head of Approvals Claire Curtis-Thomas Originally certificated on 28 March 2008 Construction Products Chief Executive The BBA is a UKAS accredited certification body Number 113. The schedule of the current scope of accreditation for product certification is available in pdf format via the UKAS link on the BBA website at www.bbacerts.co.uk Readers are advised to check the validity and latest issue number of this Agrément Certificate by either referring to the BBA website or contacting the BBA direct. British Board of Agrément tel: 01923 665300 Bucknalls Lane fax: 01923 665301 Watford clientservices@bba.star.co.uk Herts WD25 9BA 2016 www.bbacerts.co.uk Page 1 of 10

Regulations In the opinion of the BBA, Sarnafil Adhered Roof Waterproofing Membranes, if installed, used and maintained in accordance with this Certificate, can satisfy or contribute to satisfying the relevant requirements of the following Building Regulations (the presence of a UK map indicates that the subject is related to the Building Regulations in the region or regions of the UK depicted): The Building Regulations 2010 (England and Wales) (as amended) Requirement: B4(2) External fire spread On suitable substructures, the use of the membranes will enable a roof to be unrestricted under this Requirement. See section 7 of this Certificate. Requirement: C2(b) Resistance to moisture The membranes, including joints, will enable a roof to meet this Requirement. See section 6.1 of this Certificate. Regulation: 7 Materials and workmanship The membranes are acceptable. See section 11 and the Installation part of this Certificate. The Building (Scotland) Regulations 2004 (as amended) Regulation: 8(1)(2) Durability, workmanship and fitness of materials The use of the membranes satisfies the requirements of this Regulation. See sections 10 and 11 and the Installation part of this Certificate. Regulation: 9 Building standards applicable to construction Standard: 2.8 Spread from neighbouring buildings The membranes, when applied to a suitable substructure, are classified as having low vulnerability and will enable a roof to be unrestricted under this Standard, with reference to clause 2.8.1 (1)(2). See section 7 of this Certificate. Standard: 3.10 Precipitation The membranes, including joints, will enable a roof to satisfy the requirements of this Standard, with reference to clauses 3.10.1 (1)(2) and 3.10.7 (1)(2). See section 6.1 of this Certificate. Standard: 7.1(a) Statement of sustainability The membranes can contribute to meeting the relevant requirements of Regulation 9, Standards 1 to 6 and therefore will contribute to a construction meeting a bronze level of sustainability as defined in this Standard. Regulation: 12 Building standards applicable to conversions Comments made in relation to the membranes under Regulation 9, Standards 1 to 6, also apply to this Regulation, with reference to clause 0.12.1 (1)(2) and Schedule 6 (1)(2). (1) Technical Handbook (Domestic). (2) Technical Handbook (Non-Domestic). The Building Regulations (Northern Ireland) 2012 (as amended) Regulation: 23(a)(i)(iii)(b)(i) Fitness of materials and workmanship The membranes are acceptable. See section 11 and the Installation part of this Certificate. Regulation: 28(b) Resistance to moisture and weather The membranes, including joints, will enable a roof to meet the requirements of this Regulation. See section 6.1 of this Certificate. Regulation: 36(b) External fire spread On a suitable substructure, the use of the membranes will enable a roof to be unrestricted under the requirements of this Regulation. See section 7 of this Certificate. Construction (Design and Management) Regulations 2015 Construction (Design and Management) Regulations (Northern Ireland) 2007 Information in this Certificate may assist the client, Principal Designer/CDM co-ordinator, designer and contractors to address their obligations under these Regulations. See sections: Additional Information NHBC Standards 2016 1 Description (1.2) and 3 Delivery and site handling (3.3) of this Certificate. NHBC accepts the use of Sarnafil Adhered Roof Waterproofing Membranes, provided they are installed, used and maintained in accordance with this Certificate, in relation to NHBC Standards, Part 7 Roofs, Chapters 7.1 Flat roofs and balconies and 7.2 Pitched roofs. Page 2 of 10

CE marking The Certificate holder has taken the responsibility of CE marking the products in accordance with harmonised European Standard BS EN 13956 : 2005. An asterisk (*) appearing in this Certificate indicates that data shown are given in the manufacturer s Declaration of Performance. Registered Contractors Scheme (1) The Certificate holder operates a Registered Contractors Scheme for these products under which contractors are trained, registered and regularly reviewed by the Certificate holder to demonstrate that they are competent to carry out installation in accordance with this Certificate. Details of Registered Contractors are available from the Certificate holder. Registered Contractors are responsible for each installation of the products they undertake. (1) The Certificate holder s records relating to their Registered Contractors Scheme will be audited annually by the BBA as part of its programme of surveillance. Technical Specification 1 Description 1.1 Sarnafil Adhered Roof Waterproofing Membranes comprise: Sarnafil G410-EL a multi-layer roof waterproofing membrane based on plasticised PVC incorporating UV- and flame-retardant stabilisers and a non-woven glassfibre inlay. The product is available in Standard and Fleece-backed (G410-ELF) versions and with a self-adhesive polyester fleece backing (G410-EL FSA) Sarnafil TG76 a multi-layer synthetic roof waterproofing membrane based on flexible polyolefins (FPO) with a non-woven glassfibre inlay. 1.2 The membranes are manufactured to the nominal characteristics given in Table 1. Table 1 Nominal characteristics Characteristic (unit) Sarnafil G Sarnafil TG76 Standard G410-EL Fleece backed G410-ELF G410-EL FSA *Thickness (mm) 1.2 1.5 1.8 2.0 1.2 1.5 1.8 2.0 1.5 1.8 1.2 1.5 Roll length (m) 20 20 15 15 20 15 15 15 15 15 20 20 Roll width (m) 2, 3 2, 3 2, 3 2, 3 2 2 2 2 2 2 2 2 Mass per unit area (kg m 2 ) 1.6 2.0 2.3 2.6 1.9 2.3 2.7 3.1 2.7 2.3 1.5 1.8 Colour A range of colours is available Light grey is standard Grey is standard *Tensile stress (N mm 2 ) longitudinal transverse *Elongation (%) longitudinal transverse *Tensile strength (N 50 mm 1 ) longitudinal transverse *Elongation longitudinal transverse 9.5 9.0 220 200 10 9.0 220 200 10 9.0 250 230 10 9.0 250 230 0 0 *Joint peel resistance (N 50 mm 1 ) 300 300 300 300 300 300 300 300 300 300 300 300 *Joint shear resistance (N 50 mm 1 ) 600 600 600 600 600 600 600 600 600 600 500 500 *Foldability at low temperature ( C) 25 25 25 25 25 25 25 25 25 25 30 30 *Watertightness Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass 1.3 Ancillary items necessary for installation of the products and included in this assessment are: Sarnacol 2170 adhesive for bonding G410 membrane to the substrate Sarnacol 2142S adhesive for bonding G410-ELF and TG76 membrane to the substrate Sarnacol 2172 Spray adhesive for bonding G410 membranes to the substrate Primer 600 for use on PIR insulation boards, OSB and insulated metal sandwich panels Primer 610 spray primer for use on PIR insulation boards, plywood, OSB and insulated metal sandwich panels. 700 700 700 700 800 600 50 50 800 600 50 50 Page 3 of 10

1.4 Other items or components which may be used with the products but which are outside the scope of this Certificate are: Sarnacol 2162 a one-component polyurethane adhesive for bonding insulation boards Sarnafil T Clean a cleaning agent for the TG76 membrane Sarnafil G445 a protection sheet for G410 membranes Sarnafil T Prep a seam preparation for use prior to hot-air welding Sarnafil TG76 and degreasing metal SarnaVap 500E, 1000E and 2000E polyethylene vapour control layers SarnaVap 5000E SA a self-adhered, bituminous vapour control layer SarnaTred Walkway pads for roof maintenance/access Sarnatherm a range of thermal insulations comprising rigid urethane foam, expanded polystyrene and extruded polystyrene. 2 Manufacture 2.1 The products are manufactured by extrusion coating plasticised PVC and FPO into sheets. The sheets are then reinforced with a scrim in between. 2.2 As part of the assessment and ongoing surveillance of product quality, the BBA has: agreed with the manufacturer the quality control procedures and product testing to be undertaken assessed and agreed the quality control operated over batches of incoming materials monitored the production process and verified that it is in accordance with the documented process evaluated the process for management of nonconformities checked that equipment has been properly tested and calibrated undertaken to carry out the above measures on a regular basis through a surveillance process, to verify that the specifications and quality control operated by the manufacturer are being maintained. 2.3 The management system of Sika Limited has been assessed and registered as meeting the requirements of BS EN ISO 9001: 2008 and BS EN ISO 14001 : 2004 by SQS (Certificate 31982). 2.4 The products are manufactured in Switzerland and marketed in UK by the Certificate holder. 3 Delivery and site handling 3.1 The membranes are delivered to site in rolls packaged in polythene bearing a label with product identification, stock number, lot number, bulk roll number, area, date code and the BBA logo incorporating the number of this Certificate. 3.2 Rolls should be stored in a cool, dry area on a clean, level surface, and kept under cover. They should only be unwrapped from packaging at the time of installation and unused membrane should be returned to its packaging until required. 3.3 The Certificate holder has taken the responsibility of classifying and labelling the products under the CLP Regulation (EC) No 1272/2008 on the classification, labelling and packaging of substances and mixtures. Users must refer to the relevant Safety Data Sheet(s). Assessment and Technical Investigations The following is a summary of the assessment and technical investigations carried out on Sarnafil Adhered Roof Waterproofing Membranes. Design Considerations 4 General 4.1 Sarnafil Adhered Roof Waterproofing Membranes are satisfactory for use as adhered waterproofing installations on flat and pitched roofs with limited access. 4.2 Limited access roofs are defined for the purpose of this Certificate as those subjected only to pedestrian traffic for maintenance of the roof covering, cleaning of gutters etc. Where traffic in excess of this is envisaged, additional protection to the membrane must be provided (see section 9). 4.3 Flat roofs are defined for the purpose of this Certificate as those having a minimum finished fall of 1:80. Pitched roofs are defined as those having a fall in excess of 1:6. For design purposes, twice the minimum finished fall should be assumed, unless a detailed analysis of the roof is available, including overall and local deflection and direction of falls. 4.4 Decks to which the membranes are to be applied must comply with the relevant requirements of BS 6229 : 2003 or BS 8217 : 2005 and, where appropriate, NHBC Standards 2016, Chapter 7.1. 4.5 Insulation materials to be used in conjunction with the membranes must be in accordance with the Certificate holder s instructions and be: as described in the relevant clauses of BS 8217 : 2005, or the subject of a current BBA Certificate and be used in accordance with, and within the scope of, that Certificate Page 4 of 10

included in the Certificate holder s Adhered Systems Insulation List. The insulation must be attached independently to the substrate. 4.6 The Sarnafil G410 membrane must not be laid directly onto expanded polystyrene or on timber substrates impregnated with substances containing solvents or oil (eg oil-based preservatives) and can be adversely affected by contact with bituminous or coal tar products or polystyrene insulation boards. In these situations the felt-backed membrane or a suitable separation layer must be used. Where doubt arises, the advice of the Certificate holder should be sought. 5 Practicability of installation The membranes should only be installed by members of the Certificate holder s Registered Contractors Scheme (see the Additional Information part of this Certificate). 6 Weathertightness 6.1 The membranes, including joints, when completely sealed and consolidated, will adequately resist the passage of moisture into the building and enable a roof to comply with the requirements of the national Building Regulations. 6.2 The membranes are impervious to water and will provide a weathertight roof covering capable of accepting minor structural movement without damage. 7 Properties in relation to fire 7.1 The following will be unrestricted by the national Building Regulations: an 18 mm thick OSB deck, one layer of SarnaVap 5000E SA vapour control layer, one layer of 100 mm thick PIR insulation and one layer of Sarnafil G410-12EL fully bonded using Sarnacol 2170 an 18 mm thick OSB deck, one layer of bitumen vapour control layer, one layer of 100 mm PIR insulation and one layer of Sarnafil G410-12EL fully bonded using Sarnacol 2170 an 18 mm thick OSB deck, one layer of SarnaVap 500E vapour control layer, one layer of 150 mm thick EPS insulation and one layer of Sarnafil G410-12EL fully bonded using Sarnacol 2142S an 18 mm thick OSB deck, one layer of SarnaVap 5000E SA vapour control layer, one layer of 100 mm thick PIR insulation and one layer of Sarnafil G410-12EL fully bonded using Sarnacol 2170 an 18 mm thick plywood deck and one layer of Sarnafil G410-12EL fully bonded using Sarnacol 2170 an 18 mm thick OSB deck, one layer of SarnaVap 5000E SA vapour control layer, one layer of 100 mm PIR insulation and one layer of Sarnafil G410-12ELF fully bonded using Sarnacol 2142S an 18 mm thick plywood deck, one layer of bitumen vapour control layer, one layer of 75 mm thick mineral wool insulation and one layer of polyester fleece-backed Sarnafil TG76 fully bonded using Sarnacol 2142S an 18 mm thick plywood deck, one layer of bitumen vapour control layer, one layer of 100 mm thick PIR insulation and one layer of polyester fleece-backed Sarnafil TG76 fully bonded using Sarnacol 2142S an 18 mm thick plywood deck, one layer of Sarnavap 500E vapour control layer, one layer of 100 mm thick PIR insulation board primed with Primer 600, and one layer of Sarnafil G410-15 EL FSA an 18 mm thick plywood deck, one layer of Sarnavap 500E vapour control layer, one layer of 100 mm thick PIR insulation board, and one layer of Sarnafil G410-15 EL FSA an 18 mm thick plywood deck, one layer of SarnaVap 5000E SA vapour control layer, one layer of 120 mm thick tissue-faced PIR Insulation board, and one layer of Sarnafil G410-12EL fully bonded with Sarnacol 2172 adhesive. 7.2 When tested and classified in accordance with EN 13501-5 : 2005, the following systems achieved a B ROOF t(4) classification: an 18 mm thick plywood deck, one layer of Sarnavap 500E vapour control layer, one layer of 100 mm thick PIR insulation board primed with Primer 600, and one layer of Sarnafil G410-15 EL FSA an 18 mm thick plywood deck, one layer of Sarnavap 500E vapour control layer, one layer of 100 mm thick PIR insulation board, and one layer of Sarnafil G410-15 EL FSA an 18 mm thick plywood deck, one layer of SarnaVap 5000E SA vapour control layer, one layer of 120 mm thick tissue-faced PIR Insulation board, and one layer of Sarnafil G410-12EL fully bonded with Sarnacol 2172 adhesive. 7.3 The designation of other specifications (eg on combustible substrates) should be confirmed by: England and Wales test or assessment in accordance with Approved Document B, Appendix A, clause A1 Scotland test to conform to Mandatory Standard 2.8, clause 2.8.1 (1)(2), Annex 2C (1) Technical Handbook (Domestic). (2) Technical Handbook (Non-Domestic). Northern Ireland test or assessment by a UKAS accredited laboratory, or an independent consultant with appropriate experience. Page 5 of 10

8 Resistance to wind uplift The adhesion of the membranes will be limited by the cohesive strength of the substrate. On substrates with high cohesive strength, the adhesion of the membrane or of a fleece-backed version of the membrane is sufficient to resist the effect of wind suction, thermal cycling or minor structural movements likely to occur in service. The Certificate holder assumes liability for the calculations for the adhered system and provides a project specific design service which takes into account all the relevant information supplied. 9 Resistance to foot traffic The membranes can accept the limited foot traffic and light concentrated loads associated with installation and maintenance. Reasonable care should be taken to avoid puncture by sharp objects or concentrated loads. Where traffic in excess of this is envisaged, such as for maintenance of lift equipment, a walkway should be provided using SarnaTred walkway pads or concrete slabs on paving support pads. 10 Maintenance 10.1 The products must be the subject of annual inspections and maintenance to ensure continued performance. Exposed membrane must be free from the build-up of silt, unwanted vegetation and other debris. 10.2 A planned maintenance cycle, including inspections by the Certificate holder at minimum intervals of five years, should be introduced if an extended service life is required. The Certificate holder can advise on methods of extending the service life. This could include the use of thicker membranes, specific maintenance requirements or localised replacement and repair. 10.3 Where damage has occurred, it should be repaired in accordance with section 16 and the Certificate holder s instructions. 11 Durability 11.1 The durability of all roofing materials is dependent on the roof design, installation, immediate environment, maintenance and use. Other specific factors assessed by the BBA relating to the durability of individual products include formulation, thickness, and life to first maintenance. Sarnafil G410 11.2 Accelerated weathering tests and performance in use confirm that satisfactory retention of physical properties is achieved. Available evidence indicates that the membrane will have a service life in excess of 35 years. 11.3 The products have been in use in Switzerland and the UK since 1968 and 1980 respectively. The BBA has examined the oldest available sites where the material has been installed. Tests conducted on the naturally aged material taken from existing sites and naturally aged material which has been subjected to further ageing conditions confirm satisfactory retention of properties, indicating that a service life in excess of 40 years can be achieved with periodic maintenance as stated in section 10. Sarnafil TG76 11.4 Sarnafil TG76 has been used in Switzerland and the UK since 1989 and 1992 respectively. Accelerated weathering tests and performance in use confirm satisfactory retention of physical properties is achieved. Available evidence indicates that the membrane will have a service life in excess of 25 years. 12 Reuse and recycleability The products comprise polyvinyl chloride, flexible polyolefins, polyester and glass, which can be recycled. Installation 13 General 13.1 Installation of Sarnafil Adhered Roof Waterproofing Membranes (see Figure 1) must be carried out by trained and approved installers working in accordance with the relevant clauses of the Certificate holder s instructions and BS 8217 : 2005 and BS 8000-4 : 1989. Page 6 of 10

Figure 1 Typical installations Sarnacol 2170 adhesive Sarnafil G membrane adhered Sarnacol 2142S adhesive Sarnafil TG76 membrane adhered SarnaVap 5000E SA VCL SarnaVap 5000E SA VCL SarnaTherm insulation bonded in Sarnacol 2162 Structural deck SarnaTherm insulation bonded in Sarnacol 2162 Structural deck 13.2 Substrates to which the membranes are to be applied must be sound, dry, clean and free from sharp projections such as nail heads and concrete nibs. 13.3 Installation should not be carried out during wet weather (eg rain, fog or snow) or when the temperature is below 5 C. 14 Procedure Sarnafil G410 14.1 Sarnacol 2170 is applied to the substrate and allowed to dry. Sarnafil G410-12EL is unrolled onto the surface and approximately one-third of its length folded back to expose the underside. Sarnacol 2170 is applied to the membrane (200 g m 2 ) and substrate (300 g m 2 to 800 g m 2 ) depending on texture. When the adhesive has dried to the point that strings are formed on touching with a finger, the two adhesive-coated surfaces are brought into contact and the surface of the membrane is rolled with a water-filled roller. This is then repeated over the rest of the sheet. 14.2 When the adhered membrane is used over insulation products, the resistance to wind uplift will be limited by the cohesive strength of the insulation, and the method of attachment. These factors should be taken into account when selecting the insulation material. Insulation boards can be either fully adhered, using Sarnacol 2162 or hot bitumen, or be mechanically fastened. Sarnacol 2170 must not be used directly on polystyrene products. 14.3 The membrane is mechanically fixed at the perimeter and then lap jointed. 14.4 Sarnafil G410-ELF can be fully adhered using Sarnacol 2170 or Sarnacol 2142S adhesives, depending upon the substrate. 14.5 When using Sarnacol 2170 adhesive, a primer coat of the adhesive is applied to the substrate and allowed to dry. The membrane is unrolled onto the surface and approximately half of its length folded back to expose the underside. Sarnacol 2170 is applied to the previously primed area. The membrane is immediately unrolled directly onto the wet adhesive and the surface of the membrane is rolled with a water-filled roller. The other half of the membrane is folded back and the procedure is repeated. 14.6 When using Sarnacol 2142S, the membrane is unrolled onto the substrate and approximately half of its length is rolled back to expose the underside. A coat of Sarnacol 2142S is applied to the substrate, covering only the area where the membrane is to be laid. The membrane is immediately unrolled onto the wet adhesive, ensuring that the weld area is kept adhesive free, and the surface of the membrane is rolled with a water-filled roller. The other half of the membrane is folded back and the procedure repeated. 14.7 When using Sarnacol 2172 adhesive, a primer coat of the adhesive is applied to the substrate and allowed to dry. The membrane is unrolled onto the surface and approximately half of its length folded back to expose the underside. Sarnacol 2172 is applied to the underside of the membrane. Once the adhesive is tacky, the membrane is laid on the substrate and pressed down with a heavy roller. The other half of the membrane is folded back and the procedure repeated. 14.8 When using Sarnafil G410-EL FSA self-adhesive membranes, the substrate is cleaned if required and the membrane is unrolled and laid in position. The substrate may require preparing with Primer 600/610 subject to wind uplift. The protective liner is removed from the self-adhesive backing and the surface of the membrane is brushed with a broom for full contact with the substrate. The surface is then pressed down with a roller of approximately 50 kg in weight to ensure full surface bond to the substrate. Adjoining sheets are overlapped by 60 mm. Seams overlaps are welded by hot air (see section 15). Page 7 of 10

Sarnafil TG76 14.9 Sarnafil TG76 is unrolled onto the substrate and approximately half its length rolled back to expose the underside. 14.10 A coat of Sarnacol 2142S is applied to the substrate covering only one area where the membrane is to be laid. 14.11 The membrane is immediately unrolled onto the wet adhesive, ensuring that the weld area is kept adhesivefree, and the surface of the membrane is rolled with a water-filled roller. The other half of the membrane is folded back and the procedure repeated. 15 Jointing and flashing 15.1 Jointing is achieved by hot-air welding with the temperature set in accordance with the Certificate holder s instructions. 15.2 The welding area must be dry and clean. If the membrane in the welding area is oxidised owing to prolonged outdoor exposure, or contaminated, it must be cleaned in the prescribed manner. When installing Sarnafil TG76 only, Sarnafil T Prep should be allowed to totally flash off prior to welding. 15.3 The welded width of the joint must be a minimum of 25 mm. Care must be taken to ensure that overheating of the membrane does not occur, as scorching and carbonisation of the membrane will result. 15.4 The seam must be tested with a suitable metal probe and any weakness immediately repaired. 15.5 Flashing and detailing are formed in accordance with the Certificate holder s instructions. 16 Repair Any damage must be repaired by cleaning the affected area and applying a patch as described in the Certificate holder s instructions. Technical Investigations 17 Tests The following tests were carried out on samples of the membranes and the results assessed: on Sarnafil G410 tensile strength* elongation at break* tear resistance dimensional stability* heat ageing (56 days at 80 C) followed by tensile strength and elongation UV ageing (500 light hours using UVB 313 lamps cycling 4 hours UV at 45 C and 4 hours condensation at 40 C) followed by tensile strength and elongation apparent density water vapour permeability ash content static indentation on hard and soft substrate* low temperature flexibility* thickness* resistance to root penetration* peel resistance of joints* shear resistance of joints* dynamic indentation on perlite board and expanded polystyrene* resistance to wind uplift thermal shock water vapour resistance resistance to sliding at 90 C resistance to water pressure (6 m head) peel resistance when applied to chipboard, concrete, perlite and polyisocyanurate substrates (using Sarnacol 2170 adhesive applied to Sarnafil G410-12EL) peel resistance from a concrete substrate without ageing, after 56 days heat ageing at 80 C and after 28 days water soak at 20 C (using Sarnacol 2170 adhesive) resistance to cyclic movement air pressure resistance of joints tensile strength of welded joint after 28 days heat ageing at 80 C tensile strength of welded joint (longitudinal and transverse) after 7 days water soak at 60 C Page 8 of 10

on Sarnafil G410-18EL FSA resistance to wind uplift peel strength from concrete on controls and after 28 days ageing at 70 C on Sarnafil TG76 tensile strength elongation dimensional stability tear strength static indentation on EPS and concrete dynamic indentation on EPS and perlite board water vapour permeability water vapour resistance resistance to cyclic movement peel resistance heat ageing (28 days at 80 C) followed by resistance to peel and resistance to cyclic movements (200 cycles) water soak (28 days at 60 C) followed by resistance to peel. 18 Investigations 18.1 Tests were conducted on a material of similar formulation to Sarnafil TG76 and the results were assessed for: tensile strength and elongation resistance to water pressure resistance to nail tear resistance to folding at low temperatures resistance to leakage at joints tensile strength of joints peel strength of joints. 18.2 The manufacturing process was evaluated, including the methods adopted for quality control, and details were obtained of the quality and composition of the materials used. 18.3 An evaluation was made of existing data on fire performance. 18.4 A survey of known users was carried out to assess the performance in use of the systems. 18.5 A reassessment of the Durability statement for Sarnafil G410 was based on visits to existing sites in Switzerland and in the UK and the results of tests conducted on unaged, naturally-aged and accelerated-aged material. 18.6 A reassessment of the Durability statement for Sarnafil TG76 was based on visits to existing sites in Europe and on the results of tests conducted on a material of similar formulation in both unaged and naturally-aged conditions. Bibliography BS 6229 : 2003 Flat roofs with continuously supported coverings Code of practice BS 8000-4 : 1989 Workmanship on building sites Code of practice for waterproofing BS 8217 : 2005 Reinforced bitumen membranes for roofing Code of practice BS EN 13956 : 2005 Flexible sheet for waterproofing Plastic and rubber sheets for roof waterproofing Definitions and characteristics BS EN ISO 9001 : 2008 Quality management systems Requirements BS EN ISO 14001 : 2004 Environmental management systems Requirements with guidance for use EN 13501-5 : 2005 Fire classification of construction products and building elements Classification using data from external fire exposure to roofs tests Page 9 of 10

Conditions of Certification 19 Conditions 19.1 This Certificate: relates only to the product/system that is named and described on the front page is issued only to the company, firm, organisation or person named on the front page no other company, firm, organisation or person may hold or claim that this Certificate has been issued to them is valid only within the UK has to be read, considered and used as a whole document it may be misleading and will be incomplete to be selective is copyright of the BBA is subject to English Law. 19.2 Publications, documents, specifications, legislation, regulations, standards and the like referenced in this Certificate are those that were current and/or deemed relevant by the BBA at the date of issue or reissue of this Certificate. 19.3 This Certificate will remain valid for an unlimited period provided that the product/system and its manufacture and/or fabrication, including all related and relevant parts and processes thereof: are maintained at or above the levels which have been assessed and found to be satisfactory by the BBA continue to be checked as and when deemed appropriate by the BBA under arrangements that it will determine are reviewed by the BBA as and when it considers appropriate. 19.4 The BBA has used due skill, care and diligence in preparing this Certificate, but no warranty is provided. 19.5 In issuing this Certificate, the BBA is not responsible and is excluded from any liability to any company, firm, organisation or person, for any matters arising directly or indirectly from: the presence or absence of any patent, intellectual property or similar rights subsisting in the product/system or any other product/system the right of the Certificate holder to manufacture, supply, install, maintain or market the product/system actual installations of the product/system, including their nature, design, methods, performance, workmanship and maintenance any works and constructions in which the product/system is installed, including their nature, design, methods, performance, workmanship and maintenance any loss or damage, including personal injury, howsoever caused by the product/system, including its manufacture, supply, installation, use, maintenance and removal any claims by the manufacturer relating to CE marking. 19.6 Any information relating to the manufacture, supply, installation, use, maintenance and removal of this product/ system which is contained or referred to in this Certificate is the minimum required to be met when the product/system is manufactured, supplied, installed, used, maintained and removed. It does not purport in any way to restate the requirements of the Health and Safety at Work etc. Act 1974, or of any other statutory, common law or other duty which may exist at the date of issue or reissue of this Certificate; nor is conformity with such information to be taken as satisfying the requirements of the 1974 Act or of any statutory, common law or other duty of care. British Board of Agrément tel: 01923 665300 Bucknalls Lane fax: 01923 665301 Watford clientservices@bba.star.co.uk Herts WD25 9BA 2016 www.bbacerts.co.uk Page 10 of 10