passive fiber infrastructure

Similar documents
Fiber Solutions for Access and Transport Networks

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

Reliable, Consistent, Quality

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

FACT OPTICAL DISTRIBUTION FRAME SYSTEM

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

ETD Fiber Optic Products

Wall Mounted Products

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

Pretium Connector Housings

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

HARTING Ethernet Cabling 8-poles Overview

PURE : REliable planning of data center cabling

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Fiber Optic. Passive Components Edition 2009

LANC Fibre Patch Panel Solution

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

Cable Assembly Solutions at the Speed of Light

Advantages of Fiber Optic Splitters in Key Applications Increase the Efficient Use of Optical Infrastructure with These Passive Components

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

2178-S Fiber Optic Splice Case

Patch Cords for Data Center Applications

Fiber Optics in Harsh Environment Applications

7.4 3M No Polish Connector

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

HARTING Ethernet Cabling 4-poles Overview

Fiber-to-the-Home/FTTH

FTTH ARCHITECTURE WHITE PAPER SERIES

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

FTTX Solutions FDH 3000 Cross-Connect

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

FTTx Optical Fiber Cable for Easy Mid-Span Access ( EZremove )

Secure/Keyed LC System Solutions Overview

ADC Structured Cabling Solutions

New Wiring Technology for Cost-effective Construction of FTTH Networks Using Free Branch Cable

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

Cabcon. Data Centre Solutions. an acal group company UK +44 (0) IRE (00353)

Mini USB and USB 2.0-IP67 Connector System

Fiber Optic Cable

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

InstaPATCH ZERO Solution Guide

Accelerating Light. Copper Cabling Solutions. Category 6A

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs)

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

ADC-APC Integrated Cisco Data Center Solutions

Belden. Optical Fiber Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems

1U Multi-Function Fibre Enclosure

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

ENGINEERING COMMITTEE Construction and Maintenance Subcommittee

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

MPO. Fast Fibre Solution for Data Centres

1 FOSC cover 1 piece Protecting fiber cable splices in whole 2 FOSC bottom 1 piece Fixing reinforced core, fiber cable

FiberGuide Fiber Management Systems. 4th Edition

Security & Surveillance Cabling Systems

Fibre Optic Cable. Catalogue.

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

How To Make A Fibre Cable For A Data Centre

HARTING Ethernet Cabling 4-poles Overview

4 Installation Requirements

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

Optical Fibers Fiber Optic Cables Indoor/Outdoor

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

Cabling Technologies Providing More Optical Cabling Potential in Multi-dwelling Unit Buildings

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

Understanding and Optimizing MDU Optical Cabling Systems

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

AMP NETCONNECT Data Center Cabling Solutions

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance

DATA CENTER SOLUTIONS. MTP cables Patchcords Cat 6A PDU

Fiber-optic cable drums. Mobile. Robust. Individual. Excellence, that connects. Sachsenkabel Cable drums

SECTION O FIBER OPTICS

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley

FTTX Solutions. Multiport Service Terminal (MST) and Hardened Drop Cables. Benefits:

Copper Pre-terminated Assemblies

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

FDC Hardware Product Family

Plug & Play Universal Systems

BELFLOW SERIESS FIBER DISTRIBUTION FIBER DISTRIBUTION BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN.

Transcription:

passive fiber infrastructure EFFICIENCY AND QUALITY Ericsson offers cost-efficient and scalable fiber optic network products to enable your lowest Total Cost of Ownership. Our commitment to quality and sustainability ensures future-proof solutions.

Contents Central Termination Point Central Office Related Equipment Equipment Rack Systems...6 Optical Distribution Frames...7 Patch Cords, Pigtails and Cable Assemblies...10 Splitters and Other Passive Optical Devices...12 Fiber Optic Accessories...13 Fiber Access Network Feeder Network and Distribution Network...16 Ericsson Micronet Air Blown Micro Cable...16 Microducts and Multiducts for Micro Cables...17 Duct Joints and Duct Accessories...18 Fiber Distribution Hubs...20 Drop and Premises Networks...21 Ribbonet Air Blown Fiber...21 Microducts and Multiducts for Air Blown Fiber...22 Duct Joints and Other Duct Equipment...23 Fiber Access Terminals...26 Installation Tools and Accessories...28 Drop Cables...30 Fiber Termination Boxes and O/E Conversion...32 This catalog gives an overview of the Ericsson fiber optic products and passive network solutions. It does not cover every aspect that needs to be considered when deciding what type of product to choose. More detailed information can be found in the Ericsson online product catalogue at www.ericsson.com (see Products/Cables and Interconnect) Ericsson AB Sweden Phone: +46 10 719 00 00 Certification Ericsson is ISO 9001:2000 (Quality Management) and ISO 14001:2004 (Environmental Management) certified by Det Norske Veritas (DNV). Fiber Transport Network Outdoor Installation...33 Cables for Duct Installation...33 Cables for Direct Buried Installation...36 Cables for Aerial Installation...39 Joint Closures for Fiber Optic Cables...41 Submarine Installation...43 Local Site Cabling...46 Cables for Indoor Installation...46 Cables for Indoor/Outdoor Installation...48 Abbreviations...50 All Ericsson products for all markets are RoHS (Restriction of hazardous substances) compliant. 3

The passive infrastructure in any fiber optic network is a long-term investment. It needs to be built on scalable and future-proof technology that is optimized in terms of capacity, quality and operational expenditure. This catalog presents an overview of our Passive Fiber Infrastructure offering. The offering includes ducts, air blown fiber systems, traditional optical fiber cables, optical distribution frames, tools and other installation accessories, all optimized for their specific application. All products are designed and tested to meet the highest quality and environmental standards. In addition to this, Ericsson provides end-to-end solutions for any fiber optic infrastructure, as well as system integration and managed services. The catalogue is divided into three main sections: Central Office Related Equipment covers products that are common in any type of network, regardless of application. Equipment racks, Optical Distribution Frames (ODFs), patch cords and other fiber optic accessories are found here. Fiber Access Network covers products for efficient installation of access networks, including Fiber-to-the- Home (FTTH), Building (FTTB), Curb (FTTC) and similar architectures. This section also covers products for scalable campus and metro networks. Ericsson s air blown fiber system Ribbonet and Ericsson s micro cable system, as well as components for efficient splicing and termination of access networks, are presented. Fiber Transport Network covers products for general network applications such as fiber optic cables for underground, aerial and submarine installation as well as local site cabling. This section also includes associated cables and components for splicing and termination of cables. For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 5

Central Termination Point Central Office Related Equipment BAB 32661 Ericsson Light Weight Rack This is an open light weight rack system suitable for installation in locked room compartments, containers, etc. The 2200 mm high frame is delivered in flat packages for convenient transport and handling even in the most constrained and difficult to reach areas. The rack can easily be cut to appropriate heights. The system also contains a patch handling system and accessories for mass handling of patch cords. Type: Lightweight rack system Size: 2200x600x450mm Capacity: 48U Equipment Rack Systems Efficient termination and patch handling The Ericsson Central Termination Point offering features fiber management systems to efficiently and cost-effectively organize and terminate large quantities of fiber. The application in the central office environment is characterized by a minimum footprint in combination with class-leading capacity that allows well-organized and safe fiber termination to minimize operating errors. 1/BFM 108 213 Ericsson Multifiber Management System The Multifiber Management System is a highcapacity fiber termination rack for central office applications. The rack is equipped with fiber management through vertical and horizontal cable guides. Excess fiber is stored in a dedicated compartment. The basic system includes a 19 frame, side section with vertical patch cord overlength storage, Ericsson Equipment Rack System A multi-purpose 19 rack system suitable for installation of passive and active equipment together with the 1/BFM 108 213. The rack can also be used as a stand alone unit. For maximum flexibility, side and back covers, doors, optical Distribution Frames (ODFs), patch cables and other accessories are ordered separately. NCD 518 Fiber Jointing Cabinets Small/medium and large cabinets for handling cable splices between incoming cables entering the central office and the cables from pre-terminated ODFs. The small/medium cabinet can be equipped with 6 extra organizers. The cabinets are designed for wall mounting but the large cabinet can also be mounted in a 19 or ETSI rack. side and back covers, doors and overhead cable tray. Optical Distribution Frames (ODFs) and patch cables are ordered separately. Size: 800x1800*x400mm Capacity, equipment: 36U Capacity, connections: up to 1536 (SC) * Overhead cable channel adds 150mm to height Size: 600x1800x400mm Capacity, equipment: 36U (1536mm) Type: Cable installation, 19, ETSI or wall mount Size: Small/Medium 350x300x130mm Large 440x600x220mm Capacity: (single fiber) Small/Medium 24/96 splices Large 768 splices Optical Distribution Frames Optical Distribution Frames (ODFs) are integrated components in any fiber management system. They are available as rack-mounted units for 19 or ETSI racks, or as wall-mounted cabinets. The ODFs are available in a range of configurations depending on application: Pre-terminated ODFs with stub cables are pre-installed with connectors and cable for quick and easy installation. Units with pre-terminated cables offer advantages such as faster installation, resulting in shorter time to revenue as well as guaranteed quality and performance. Several cable options are available. ODFs with stub micro cables are especially suitable for high packing density applications such as the Ericsson Multifiber Management System (MMS). Pre-terminated ODFs, with micro cable on reel are delivered attached to a reel with longer lengths of outdoor rated micro cable, eliminating time consuming and costly splicing of cables in the central office. This is also a preferred option in combination with the Multifiber Management System. ODFs for cable installation are intended for installation and termination of all kinds of fiber optic cables. The units are suitable for splicing pigtails or fiber ribbon fanouts as well as field-installable connectors. The ODFs are delivered empty, allowing the customer to order the pigtails/fanouts, adapters, splice protection sleeves and installation kit that best suit the specific application. The units can also be installed with pre-connectorized cable assemblies. ODFs for air blown fiber are designed to handle termination of ducts for air blown fibers. They are typically used in FTTx applications when blowing fibers directly to a central office or other distribution point. The air blown technology enables incremental installation when needed. 6 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 7

NCD 513+ ODF pre-terminated, with stub cable, 2U NCD 502 5000 ODF Patch Panels Pre-terminated ODF with a capacity from 12 to 96 SC (192 LC) connectors. Options include: halogen-free, flame-retardant, loose tube, ribbon or micro cable. Optional accessories include horizontal patch cord guides for space-saving mounting directly onto the front of the ODF. Type: Pre-terminated, 19 or ETSI mount, 2U Size: 440x249x86mm Capacity: 12-96 SC, 12-192 LC Cable options: Halogen-free, flame-retardant loose tube, ribbon or micro cable, 10-100m Connector options*: SC, SC/APC, LC, LC/APC * MU, E2000, ST, FC, MT-RJ available on request Multi-purpose patch panels for central office equipment rack systems where no or limited access from the rear require total front access. The light-weight panel is divided in a left and right swingable section. Small system footprint and efficient workspace. Designed for pre-connected incoming cable assemblies. Type: Pre-connected cable assemblies Size: 485x200x43mm Capacity: 6 basic versions with 48 or 32 SC adapters NCD 513+ ODF, 2U, Pre-terminated with longer cable lengths NCD 518 1200 ODF for cable installation, wall mounted Pre-terminated ODF delivered with longer lengths of micro cable, typically up to 2000m. The unit is available with SC or LC connectors with a capacity of 12 to 96 connectors. Optional accessories include horizontal patch cord guides for spacesaving mounting directly onto the front of the ODF. Type: Pre-terminated on reel, 19 or ETSI mount, 2U Size: 440x249x86mm excluding reel Capacity: 12-96 connectors Cable options: Micro cable, 10-2000m Connector options: SC, SC/APC, LC, LC/APC Two-sided ODF with a capacity of up to 48 SC (96 LC) connectors. The ODF consists of two compartments with separate locks and is therefore suitable as a demarcation cabinet between different network owners. The cabinet can also be used as a jointing box. Optional accessories include patch panels for different adapter types. Type: Cable installation, wall mount Size: 475x300x130 mm Capacity: 48 SC, 96 LC Connector options: SC, SC/APC, LC, LC/APC, ST, FC, MT-RJ NCD 513+ ODF for cable installation, 2U Patch Handling High capacity ODF with up to 96* SC connectors. Optional accessories include horizontal patch cord guides for space-saving mounting directly onto the front of the ODF, pigtails, fanouts, adapters, splice sleeves, etc. Type: Cable installation, 19 or ETSI mount, 2U Size: 440x249x86mm Capacity: 96 SC Connector options: SC, SC/APC, LC, LC/APC, MU, E2000, ST, FC, MT-RJ * The capacity refers to splicing of fanouts (ribbon). Maximum capacity for pigtails may be reduced. There are a number of accessories available for handling of patch cables in rack systems such as storage unit, cable guides and end plugs. NCD 513+ ODF for cable installation, 1.5U BMF 904 41/1 and BMF 904 45 Flexfield Modules ODF with a capacity of up to 48 SC (96* LC) connectors. Optional accessories include horizontal patch cord guides for rack mounting directly under the ODF, pigtails, fanouts, adapters, splice sleeves etc. Type: Cable installation, 19 or ETSI mount, 1.5U Size: 440x247x66mm Capacity: 48 SC, 96 LC Connector options: SC, SC/APC, LC, LC/APC, MU, E2000, ST, FC, MT-RJ * The capacity refers to splicing of fan-outs. Maximum capacity for pigtails may be reduced. Flexible ODF modules for SC connectors with 2x2, 4x2 or 6x2 SC adaptors of singlemode quality. Flexible CAT6 modules for RJ45 connectors in the front and IDC terminators on the inside. Capacity: 6x2 SC ODF module, 6 RJ-IDC CAT6 module NCD 520 0013 ODF for air blown fiber installation, 1U NBA 101 17 Flexfield Subracks Compact ODF with front access for simplified incremental installation of air blown fiber. The ODF has a capacity up to 48 SC (96* LC) connectors and clamps for up to 48 microducts. Optional accessories include horizontal patch cord guides, pigtails, fanouts, adapters, splice sleeves etc. Type: Air blown fiber installation, front access, 19 mount, 1U Size: 450x280x44mm Capacity: 48 SC, 96 LC Connector options: SC, SC/APC, LC, LC/APC, MT-RJ * The capacity refers to splicing of fanouts. Maximum capacity for pigtails may be reduced. There are several types of mechanics available for 1, 2 or 10 mounted modules. 8 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 9

Patch Cords, Pigtails and Cable Assemblies Ericsson s fiber optic patch cords, pigtails and cable assemblies make up a full product range of fiber optic interconnections for use in any kind of environment. We provides virtually any type of fiber optic connector. Some examples are shown below. TSR 395+ Patch Cords, Pigtails and Fanouts, Standard grade A series of patch cords, pigtails and fanouts that offers best price/performance ratio for access networks as well as general data communication applications. The products are made of bend resistant G657 fibers to minimize operating errors and enable highest packing density in interconnect applications. Connector options: SC, SC/APC, LC, LC/APC Performance: IL Typical* 0.25, RL (PC) 50, RL (APC) 60 Standard length: 1, 2, 3, 5, 10m * Insertion Loss against reference connector is according to IEC 61300-3-4 method B TSR 391+, TSR 392+ Patch Cords, Pigtails and Fanouts, High grade SC SC/APC SCMM LC LC/APC MU E2000 FC/PC MT-RJ ST Premium patch cords, pigtails and fanouts for demanding telecom applications with high requirements for stability. The product series offers the highest reliability under virtually any environmental conditions. Connector options: SC, SC/APC, LC, LC/APC, MU, E2000, E2000/APC, ST, FC Performance: TSR 391: IL Typical* (E2000) 0.2, (FC, SC) 0.1 (ST, LC) 0.15, (FC/APC) 0.12, RL 50 Performance: TSR 392: IL Typical* 0.15, (FC/ APC) 0.12, RL 60 Standard and custom lengths available * Insertion Loss against reference connector is according to IEC 61300-3-4 method B Supported fiber types are singlemode G.657 (compatible to G.652), and multimode 50μm OM2, OM3 and 62.5μm OM2. The product range is divided into four main categories: Patch cords that are used for quick and easy interconnect between line equipment or for cross connection between network interface equipment such as ODFs. Patch cords are available as simplex (1 fiber), duplex (2 fiber) and multifiber patch cables. Pigtails, stub fibers with a fitted connector on one end, are normally spliced towards a cable or other type of fiber unit inside an ODF, wall outlet or other type of network equipment. The standard pigtail is made of a 0.9mm tight secondary protected fiber. Pigtails are available for all Ericsson s connector options and fiber types. Fanouts, fiber ribbons that are branched out in one end and fitted with connectors, enable ribbon-fiber splicing, minimize splice cost and increase packing density in network equipment. Multifiber cable assemblies, or fiber optic patch cables, for interconnect appli cations are preferred when a high number of interconnections and a high packing density is required. The cable assemblies are available with 4-24 fibers and are delivered pre-terminated in one or both ends. To facilitate installation and to maximize packing density, Ericsson s multifiber cable assemblies use extra-slim cables, typically 6-8mm regardless of fiber count. TSR 394+ Patch Cords, Pigtails and Fanouts Multimode patch cords, pigtails and fanouts for various applications such as telecommunication equipment, and data communication networks. Types: Multimode 50μm OM2, OM3 or 62.5μm OM2 RPM 253+ Multifiber Cable Assemblies Patch cables with 4 to 24 fibers, for high density interconnect applications. All cable assemblies are manufactured from ultra slim cables. Connector options: SC, LC, ST, FC, MT-RJ Performance: IL Max* 0.3, RL 30 * Insertion Loss against reference connector is according to IEC 61300-3-4 method B Connector options: SC, SC/APC, LC, LC/APC Performance: See connector performance above * Insertion Loss against reference connector is according to IEC 61300-3-4 method B Patch cord Pigtail Fanout Multifiber cable assembly 10 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 11

Splitters and Other Passive Optical Devices Fiber optic splitters or couplers provide division of optical power from one or two input ports into several output ports. Symmetric optical power splitters are used for fiber optic communication systems such as PON FTTx networks. Asymmetric power splitters are used for monitoring of transmission signals in fiber networks. Fiber Optic Accessories Typical accessories for fiber optic interconnect and splicing applications include various essential and optional products such as fiber optic adapters for Optical Distribution Frames (ODFs) splice sleeves, connector cleaners, optical attenuators and labels. NCD 520 002+ Fiber Optic Splitter Shelf RNT 992+ Adapters Splitter shelf for 19 rack mounting with pre-installed fiber optic splitters. The shelves are available in different configurations with split ratios of 1x2 to 1x64. The standard connector option is SC/APC. Available in both standard and high grade. Type: Splitter Shelf, 19, 1U Size: 410x195x44mm Split ratio: 1x2 to 1x64 Fiber optic adapters for ODFs and termination units, all of premium grade to fit any kind of application. Simplex, duplex and quadruplex connector options with color coding for identifying the correct connector and fiber type are available. Connector options: SC, SC/APC, SCMM (simplex, duplex) LC, LC/APC (simplex, duplex, quad) MU (duplex) E2000, E2000 APC (simplex, duplex) FC/PC MTRJ ST FC RDB 104 16+ PLC Splitters and FBT Couplers Pigtailed PLC (Planar Lightwave Circuit) splitters and FBT (Fused Biconic Taper) couplers for fiber optic signal splitting in PON networks: The very compact size makes them suitable for instal lation in splice trays placed in joint closures, cabinets or optical termination panels. The splitters are available with one or two input ports and up to 64 output ports. The couplers are available with one or two input ports, and two output ports. Split ratio: Splitters 1x4 to 1x64, 2x4 to 2x32 Couplers 1x2, 2x2 Input: Splitters pigtail 250μm G657A Output: Splitters fiber ribbon G657A Input/output: Couplers pigtail 250μm G657A SC SC/APC SCMM LC LC/APC NBA 301 04 and NBA 301 05 Splitter Frames The indoor splitter frames are designed for compact mounting of splitter modules in 19 or ETSI racks with total front service. The most common use is for central office applications or larger distributed PON MDU sites. There are two frame heights available. Type: (04) Splitter frame 1U for up to 9 splitter modules (05) Splitter frame 4U for up to 35 splitter modules Mounting: 19 or ETSI * see splitter modules, page 20 MU E2000 FC/PC MT-RJ ST NBA 102 0001723 Asymmetric Fiber Optic Splitter Shelf The asymmetric division of the signal power is in a proportion of 10:90 split ratio which gives the ability to monitor or measure the transmission signal. The optical power splitter is mounted in a standard Ericsson 2U ODF chassis and fits both 19 and ETSI rack systems. It works both in the 1550nm and 1310nm wavelength area. The unit has 24 channels and is equipped with SC/APC connections for minimum back reflections. Type: Monitor splitter Size: 440x249x86mm Split ratio: 10:90 12 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 13

RNT 992+ End Plugs Plugs to cover unused slots in ODF panels. Slot options: SC, SC-duplex, FC Fiber Access Network NTA16212+ Splice Protection Sleeves Sleeves for protection of fiber optic fusion splices, available as single fiber sleeves or as fiber ribbon sleeves. LFS 150 101 Cleaning Sticks Dust-free, high-grade cleaning sticks specially developed to minimize the risk of cotton nap getting onto connectors during cleaning. The sticks are suitable for 2.5 adapter types or connectors mounted in adapters. SAA 901 041 Cleaning Sticks Dust-free, high-grade cleaning sticks specially developed to minimize the risk of cotton nap getting onto connectors. Extra slim for small form factor connectors (1.25mm). Sleeve types: Single fiber 40mm Single fiber 60mm Ribbon 2-12 fiber Ribbon, soft tube 2 fiber Application: SC, FC, ST, E2000 connector and adapter cleaning Type: High-grade, dust-free Application: LC, MU connector and adapter cleaning Type: High-grade, dust-free Fiber-to-the-Home (FTTH) refers to fiber optic broadband connections to individual homes. FTTH networks are deployed either as a passive optical network (PON) with a partially shared fiber infrastructure, or as a point-to-point network (P2P) with dedicated fibers to each end user. Regardless of network type, the chosen technology must be able to support a variety of changes in the future as capacity and services evolve. Ericsson s solutions for Access Networks consist of the air blown microduct systems Micronet and Ribbonet as well as traditional fiber optic cables. The products are specially developed for access networks with the highest requirements for scalability, performance and reliability. To Build for the Future Scalability The access networks built today must be scalable, not just regarding capacity, but also regarding topology. Typical examples of scalable technologies are Ericsson Ribbonet and Micronet air-blown fiber and micro cable systems, where incremental installation of fiber, easy repair and upgrade are key elements. The system scalability minimizes the total cost of ownership. Versatility It is impossible to know what technological changes will happen in the future. Therefore more network component are designed for any possible topology or combination of topologies in the same product, for example PON (P2MP) and P2P. They will also support a full transformation from PON to P2P (or vice versa) without the need for additional civil works. All of our major network components can handle any cabling type, for example air-blown fiber, micro cable, drop cables or traditional cable (a mix of the above). Sustainability All products are designed to minimize the environmental impact, from the manufacturing phase and through the whole lifecycle of the products. Total RoHS compliance and halogen-free materials are features of the entire product range. Packing materials are minimized or fully recyclable. LTT 179 001 Connector Cleaner This handy tool contains a dust-removing tape for quick and easy cleaning of connector tips. For each cleaning cycle, a new section of tape is dispensed. Refill tapes are available. Application: Connector top cleaning Type: High-grade, dust-free 14 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 15

Feeder Network and Distribution Network The Feeder and Distribution Network is the foundation of any fiber access network. The feeder network connects any central office to fiber distribution points such as Fiber Distribution Hubs (FDHs). The FDH is the location of passive fiber optic devices such as fiber optic splitters and/or cross connection facilities. The distribution network distributes fiber from the FDH to the drop network. Microducts and Multiducts for Micro Cables Microducts and multiducts are available for several installation environments such as direct buried installation, installation into existing pipes or indoor installation. Ducts for aerial applications are presented in the section Drop and Premises Networks. Ericsson Micronet Air Blown Micro Cable When deploying metropolitan and access networks, air blown micro cable technology offers great benefits. A microduct system enables quick and easy incremental installations of cables. The capacity of the network can quickly be increased by inserting new cables in spare microducts when needed The system also minimizes the number of fiber splice joints in the network compared to traditional cable solutions. The Micronet system consists of micro cables, microducts, duct joints and accessories. For our traditional loose tube and ribbon cables for the distribution and drop networks, see section Fiber Transport Network Solutions. MPB 302 7+ Protected Microducts for direct buried installation Ducts composed of 10/8mm or 12/9.6mm microducts with a heavy-duty HDPE sheath that enables direct installation in the ground. The microducts have a solid, low-friction inner surface coating for best installation performance. Type: Direct buried installation Dimensions, microducts: Ø 10/8mm or 12/9.6mm Capacity: 1, 4, 7-way TOL 401 9017+ GNHLDV Micro Cable, Outdoor MPB 302 6+ Microducts for duct installation Micro cable based on a slim loose tube design with up to eight tubes per cable. The design facilitates fiber preparation and mid-span access. The cable is suitable for long-distance, air blown installation in microducts, with an inner diameter of as little as 8mm. The cable has excellent bend performance. Design: Loose tube Type: Dielectric, slim Dimensions: Ø5.7-6.7mm Capacity: 12-96 fibers Ducts composed of 10/8mm or 12/9.6mm microducts. The ducts are designed for installation in existing pipes or cable shafts. The microducts have a solid, low-friction inner surface coating for best installation performance. Type: Installation in existing pipes Dimensions, microducts: Ø 10/8mm or 12/9.6mm TOL 405 9006 GNHQBDUV Micro Cable, Indoor MPB 302 9+ Protected Microducts for duct installation Micro cable based on a slim loose tube design with up to six tubes per cable. The design facilitates fiber preparation and mid-span access. The cable is designed for indoor installation and has excellent bend performance. Design: Loose tube Type: Halogen-free, flame-retardant Dimensions: Ø 6.2mm Capacity: 12-24 fibers Ducts based on 10/8mm or 12/9.6mm microducts with a single HDPE sheath for easy installation of microduct bundles into existing pipes or cable shafts. The microducts have a solid low friction inner surface coating for best installation performance. Type: Installation in existing pipes Dimensions, microducts: Ø 10/8mm or 12/9.6mm Capacity: 4, 7-way TOL 401 90+ GNHLDV Micro Cable, Aerial applications MPB 302 71+ and MPB 302 73+ Protected Microducts for indoor use Micro cable based on a slim loose tube design with up to eight tubes per cable. The design is optimized for the maximum strength required for air blown aerial applications. The cable is specially designed for long-distance, air blown installation in microducts with an inner diameter of as little as 8mm. Design: Loose tube Type: Dielectric, extra slim for aerial applications Dimensions: Ø5.7-6.7mm Capacity: 12-96 fibers Microduct with a sheath made of halogen-free, flame-retardant material that enables installation of outdoor rated micro cables in indoor environments. Fiber splicing between indoor and outdoor environments can therefore be eliminated. Type: Indoor Installations Dimensions, Micronet-indoor microduct: Ø 10/8mm or 12/9.6mm Micronet-indoor Capacity: 1, 4, 7-way Standard Grade Standard Grade 16 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 17

Duct Joints and Duct Accessories Successfully installing a system based on microducts requires components for splicing microducts, as well as protective closures for duct jointing and branching. NDE 451 15 (/4-6) Duct Joint Closure A series of straight duct closures for maximum protection of duct joints for direct buried applications. Heat shrink technology is used for maximum protection. The closure is available in three different sizes and includes microduct snapin connectors for 1, 4 or 7 microducts. Type: Heath shrink, straight joint Sealing: IP class 68 Capacity: 1, 4, or 7 MPB 306 01/10 and /12 Straight Connector NDE 451 25+ Duct Joint Closure Microduct snap-in connectors for quick and easy splicing of microducts. The body is transparent for easy trouble fault location during installation. Type: Straight connector Dimensions, microducts: Ø10/8mm or 12/9.6mm A series of straight duct closures for quick and easy installation without the need for heat. The closure is available in several sizes. Microduct snap-in connectors are not included. Type: Cold seal, re-enterable straight joint Sealing: IP class 68 Capacity: 1, 4, or 7 MPB 306 02/10 and /12 Gas Block Connector NDE 451 16 Duct Joint and Branch Closure Gas block microduct snap-in connectors normally used between indoor and outdoor environments to prevent air flow that may result in condensed water getting into ducts. After cable installation, the connector can be gas sealed by turning a ring on the body, which is transparent for easy fault location during installation. Type: Gas block straight connector Dimensions, microducts: Ø10/8mm or 12/9.6mm Closure suitable for branching as well as jointing ducts. The closure provides mechanical protection of the duct joints. Type: Cold seal, re-enterable branch joint Sealing: Mechanical protection only SXA 113 9137/10 and /12 End stop Connector NDE 451 40 Duct Joint and Branch Kit Microduct snap-in, end-stop connectors for permanent or temporarily sealing of unused microducts to prevent water and dust getting into the duct. The body is transparent, for easy fault location during installation. Type: End stop Dimensions, microducts: Ø10/8mm or 12/9.6mm Flexible kit including materials and tools for jointing, branching and mid-span of microducts/ multiducts. A vulcanizing cloth is used for sealing, and strong and flexible PVC tape provides mechanical protection. Refill kits are available. Microduct snap-in connectors are not included. Type: Cold seal, branch joint Sealing: IP class 68 Capacity: 10 joints/kit SXA 113 9151/10 Valve End-stop Connector SRS 1016 17+ End Caps Valve end-stop connector used for pressurizing microducts prior to installation into existing ducts. The pressurization prevents the duct from collapsing during installation. Type: Valve end stop Dimensions, microducts: Ø10/8mm Rubber covers used for for temporary sealing of unused multiducts to prevent water and dust from getting into the ducts. The caps are available in several versions for different types of ducts. Type: Rubber multiduct end caps 18 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 19

Fiber Distribution Hubs The Fiber Distribution Hub (FDH) is the location of passive fiber optic devices such as fiber optic splitters and/or cross connection facilities. In this section, FDHs for cable and microduct technologies are presented with associated accessories. For a complete list of products for fiber distribution, see also section Drop and Premises Networks/Fiber Access Terminals. Drop and Premises Networks The Drop Network connects end users to splicing and branching points, or Fiber Access Terminals (FATs) where the ducts or cables are connected to the feeder and distribution network. Drop cables or Ericsson s Ribbonet Air Blown Fiber (ABF) system are two options for connecting fibers from end users to the FAT. The Premises Network refers to the network within a customer s premises such as a home or office environment. Typical products within the premises network are Fiber Termination Units Boxes (FTBs) and various types of Customer Premises Equipment (CPE), including media converters and residential gateways. 2/NBD 116 200 Fiber Distribution Hub, Outdoor This FDH combines unique features in a compact cabinet. The FDH handles in-cabinet splicing of cable as well as incremental installation of air blown micro cable or blown fiber. The FDH is designed for both PON and P2P FTTx connections. Type: Outdoor pad or pole mount Capacity: 64-288 end users Dimensions: 830 (1080*)x700x426mm * Height including pad Ribbonet Air Blown Fiber Ericsson s Ribbonet Air Blown Fiber (ABF) system has been developed specifically to provide fast, efficient and flexible fiber distribution in the drop network. The system is recommended for medium to long-distance drop networks where substantial cost savings can be achieved by reducing the number of splice points and by installing fiber incrementally when needed. The technology also enables future expansion of the network without costly additional civil works. The Ribbonet system, consisting of ducts forming the infrastructure into which the fiber units are blown, can be used outdoors, indoors and underground, as well as in aerial applications. The Ribbonet system consists of Enhanced Performance Fiber Units (EPFUs), ducts, duct joints and accessories and an Ericsson patented lightweight air blowing tool. 1/NBD 116 200+ Fiber Distribution Hub, Indoor NTM 502+ Pre-connected Air Blown Fiber, EPFU The indoor FDH, for up to 64 end-users, is designed to handle fiber optic terminations and passive optical splitters in PON FTTx networks but can also be used for Point to Point (P2P) applications or combinations of the both. The FDH can handle air-blown fiber in microducts, micro cables as well as drop cables and other fiber op- tic cables. It can also be used as a medium sized fiber optic splice box for various applications. Type: Indoor, wall mount Capacity: 64 end-users Dimensions: 500x376x182mm Pre-connected EPFU, consisting of discrete fibers or fiber ribbons encapsulated in a round multi-layer, high-performance acrylate coating. The connected EPFU is delivered on lightweight polystyrene reels, optimized for use with the Ribbonet fiber blowing tool. The connected end is made of bend-resistant G657B fiber. The EPFU is available in configurations from 1 to 4 fibers. Types: Discrete fibers 1, 2, 4 fibers Ribbon fibers 2, 4 fibers Singlemode G652D, G657B Multimode 50μm OM2, OM3 Multimode 62.5μm OM2 Connector Options: SC, SC/APC, LC, LC/APC, ST, MT-RJ Standard lengths: 30, 50, 70, 100, 150, 200, 250, 300, 350, 400, 500...1000m 3/NBD 116 200 Fiber Distribution Hub, Outdoor, Underground NTM 502+ Air Blown Fiber, EPFU, in pan An FDH for up to 96 end-users. The main application is fiber distribution in PON networks with optical splitters, but it can also be used in a P2P system as a cross connection distribution point. The FDH is designed for outdoor underground installation in manholes but can also be mounted above ground on poles or inside pedestals. The closure can handle air-blown fibers in microducts, micro cables and traditional cables. Type: Outdoor, underground installation or pole mount. Capacity: 96 end-users Dimensions: 800x250x250mm EPFU consisting of discrete fibers or fiber ribbons, encapsulated in a round multi-layer, high-performance acrylate coating. The EPFU is delivered in pans in lengths from 2000 to 6000m. The EPFU is available in configurations from 1 to 8 fibers. Types: Discrete fibers 1, 2, 4 fibers Ribbon fibers 2, 4, 8 fibers Singlemode G652D Multimode 50μm OM2, OM3 Multimode 62.5μm OM2 Standard lengths: 2000, 4000, 6000m RDJ 901 20+ Splitter Modules Splitters to be used in the FDH. The splitters are pre-terminated with protected fanouts and with fitted connectors. The splitters can also be installed in ODFs or other compartments. Available in both high grade and standard grade and with different connectors. These splitter modules also fits in splitter frames described on page 12. Split ratio: 1x4 to 1x64, 2x4 to 2x32 Input/Output: 2mm patch, G657A1 Connector options: SC/APC, SC, LC, LC/APC 20 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 21

Microducts and Multiducts for Air Blown Fiber MPB 302 44+ and MPB 302 3+ Protected Microducts, direct-buried, dielectric or metallic moisture barrier Ducts composed of 5/3.5mm microducts with a heavy-duty HDPE sheath that enables direct buried installation. The ducts are available dielectric or with a moisture barrier of aluminum foil to prevent water diffusion when permanently submersed. The microducts have a solid, lowfriction inner surface coating for best installation performance. Type: Direct buried installation, dielectric or metallic moisture barrier Dimensions, microducts: Ø5/3.5mm Capacity: 1, 2, 4, 7, 12, 19, 24-way Duct Joints and Other Duct Equipment Successfully installing a system for air blown fiber also requires components for splicing microducts, as well as protective closures for duct jointing and branching. All underground jointing and branching products for the Ribbonet system are IP class 68 watertight. MPB 302 1+ Microduct for installation in existing pipes MPB 306 01 Straight Connector Ducts composed of 5/3.5mm microducts. The ducts are designed for installation in existing pipes or cable shafts. To prevent water diffusion when permanently submersed, a moisture barrier of aluminum foil is wrapped around the microducts. The microducts have a solid, low-friction inner surface coating for best installation performance. Type: Installation in existing pipes, metallic moisture barrier Dimensions, microducts: Ø5/3.5mm Capacity: 1, 2, 4, 7, 12, 19, 24-way Microduct snap-in connectors for quick and easy splicing of microducts. The body is transparent for easy fault location during installation. Type: Straight connector Dimensions, microducts: Ø5/3.5mm MPB 302 0+ and MPB 302 08+ Microducts, indoor, High Grade or UL Riser MPB 306 02 Gas Block Connector Microducts with a sheath made of halogenfree, flame-retardant material with High Grade or UL Riser classified. The microducts have a solid, low-friction inner surface coating for best installation performance. There is also a single microduct available with an extra protection sheath for mounting directly onto walls with cable clamps. Type: Indoor Installation, High Grade or UL Riser Dimensions, microducts: Ø5/3.5mm Capacity: 1, 2, 4, 7, 12, 19, 24-way Gas block microduct snap-in connectors normally used between indoor and outdoor environments to prevent air flow that may result in condensed water getting into in ducts. After cable installation, the connector can be gas sealed by turning a ring on the body, which is transparent for easy fault location during installation. Type: Gas block straight connector Dimensions, microducts: 5/3.5mm MPB 302 09+ Microducts for indoor installation, Standard Grade SXA 113 9137 End stop Connector Microducts with a sheath made of halogen-free, flame-retardant material with Standard Grade classification for installations with lower fire requirements. Type: Indoor installation, Standard Grade Dimensions, microducts: 5/3.5mm Capacity: 1, 2, 4, 7, 12, 19, 24-way Microduct snap-in end stop connectors for permanent or temporarily sealing of unused microducts to prevent water and dust from getting into the duct. The body is transparent for easy fault location during installation. Type: End stop Dimensions, microducts: Ø5/3.5mm MPB 302 2+ Protected Microducts, Aerial NTM 504 032 Microduct End Caps Microducts for aerial installation on poles that are self-supporting, non-metallic and lightweight to ensure quick and easy installation. The tubes include a stabilized sheath to resist the aging effects of UV radiation. The ducts are part of the Ericsson Aerial Air Blown Fiber (ABF) System and include both 5mm and 10mm ducts. Type: Aerial installation Dimensions, microducts: Ø5/3.5mm, 10/8mm Capacity: 1, 4, 12, 8+2*, 9+1*-way * Refers to number of 10/8mm microducts End caps for microducts to prevent dirt and moisture entering the tubes. The end cap also locks the installed fiber to prevent it from moving in the tube. End caps should be used for all open ends in microduct installations. The end cap is made of rubber and has a slit that allows the fiber unit to pass through. Type: End cap with strain relief Dimensions, microducts: Ø5/3.5mm 22 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 23

NDE 451 15 (/1-3) Duct Joint Closure NDE 451 22+ Duct Branch Closure, Aerial A series of straight duct closures for maximum protection of duct joints for direct buried applications. Heat shrink technology is used for maximum protection. The closure is available in five different sizes and includes microduct snap-in connectors for 1 to 24 microducts. Type: Heat shrink, straight joint Sealing: IP class 68 Capacity: 1 to 24 microducts Easy-to-use closure, primarily intended for Ericsson s Aerial Air Blown Fiber System (ABF), that can also be used for above-ground branching application of ducts. The closure uses gelseal technology for quick, safe installation. Type: Cold seal, re-enterable branch joint for aerial applications Sealing: IP class 67 Capacity: Up to 4x1-way branch off NDE 451 25+ Duct Joint Closure SRS 106 17+ End Caps A series of straight duct closures for quick and easy installation without the need for heat. The closure is available in several sizes. Microduct snap-in connectors are not included. Type: Cold seal, re-enterable straight joint Sealing: IP class 68 Capacity: 1 to 24 microducts Rubber covers used for temporarily seal of unused multiducts to avoid water and dust from getting into the ducts. The caps are available in several versions for different types of ducts. Type: Rubber multiduct end caps NDE 451 40 Duct Joint and Branch Kit NSF 151 601 and NSF 151 701 Anchoring Clamp Flexible kit including materials and tools for jointing, branching and mid-span of microducts/multiducts. A vulcanizing cloth is used for sealing and strong and flexible PVC tape provides mechanical protection. Refill kits are available. Microduct snap-in connectors are not included. Type: Cold seal, branch joint Sealing: IP class 68 Capacity: 10 joints/kit Designed for ducts with a Fiber Reinforced Plastic (FRP) messenger figure-8 shaped duct assembly. The 701 can also be mounted directly on aerial drop ducts. Type: Anchoring Clamp Capacity: (601) 8-10mm FRP or (701) 6-8mm FRP or reinforced duct 3/NDE 451 200 Duct Branch Closure NSF 151 501 Suspension Clamp The closure is intended for fast and easy branching of direct buried microduct assemblies for air-blown fiber. The typical application is to branch out 1 to 4 drop ducts to connect single family units from a main duct assembly. The closure is intended for mounting directly into the ground or in manholes, but can also be installed above ground. Type: Cold seal, re-enterable branch closure Sealing: IP class 68 Capacity: 1-24 way ducts, up to 4x1-way branch off Designed for ducts with a Fiber Reinforced Plastic (FRP) messenger figure-8 shaped duct assembly. Type: Suspension Clamp Capacity: 7-11mm FRP NDE 451 100+ Duct Branch Closure NSF 151 611 Universal Pole Bracket Branch joint closure suitable for multiducts in direct buried applications. It can be used for a large number of duct branches. The box has alternative entrances, allowing a large number of possible joint combinations, as well as mid-span access. Type: Cold seal, re-enterable branch joint Sealing: IP class 68 Capacity: 1-24-way ducts, up to 12x1-way branch off Designed for securing cable or ducts on wooden, concrete or metallic poles. Type: Pole Bracket 24 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 25

Fiber Access Terminals Fiber Access Terminals (FAT) are primarily designed for Ribbonet Air Blown Fiber installations and for changeover from fibers emerging from microducts or drop cables to all types of fiber optic distribution cables. The FATs consist of jointing cabinets and joint closures that are designed for easy access and good protection of fibers. Products for direct splicing of distribution and drop cabling sections as well as closure with connection panels are available. NBD 116 01+ FAT Fiber Jointing Cabinet Outdoor street cabinets designed for blown fiber or cable splicing. The cabinet is made of hot-galvanized steel as a basic protection against corrosion, and has a painted ground base. The visible part of the outer shelter is available unpainted or green for lowest visual impact. Type: Outdoor cabinet Size: 1200x850x220mm Sealing: IP class 45 Capacity: 192 splices, 96 microducts NCD 518 8002 FAT Fiber Jointing Cabinet NCD 507 1001 Fiber/Duct Joint Closure, Aerial Small sized cabinet intended for fiber splicing and termination of up to 48 microducts (subscribers) or drop cables. The supplied fiber organizers can typically handle up to 96 fibers. Type: Indoor cabinet, 19, ETSI or wall mount Size: 350x300x120mm Sealing: IP class 45 Capacity: 96 splices, 48 microducts Fiber joint closure optimized for Ericsson s Aerial Air Blown Fiber (ABF) System for FTTx. The closure can also be used for general purpose above-ground fiber splicing applications. Type: Outdoor closure for aerial applications, wall or pole mount Size: 300x230x110mm Sealing: IP class 54 Capacity: 48 splices NCD 518 8004/2, 3 FAT Fiber Jointing Cabinet NCD 504+ Fiber/Duct Joint Closure Medium-sized cabinet designed for fiber splicing and termination of up to 96 microducts or drop cables. Two models of cabinet are available with different types of fiber organizers for various applications. The organizers typically handle up to 192 fibers. Size: 440x300x160mm Sealing: IP class 45 Capacity: 192 splices, 96 microducts Plastic joint closure for outdoor, direct buried installations. It has a capacity of up to 24 microducts and 2 standard/micro cables. An extension ring for additional entrances is available. The fiber organizers also cater for fused fiber splitters for PON network applications. The closure can also be used in the Micronet system. Type: Outdoor plastic closure for cables and microducts Size: 342x262x140mm Sealing: IP class 68 Capacity: 24 single fibers (48 single fibers*), 24 microducts * With additional splice trays NCD 518 8003 FAT Fiber Jointing Cabinet NCD 506 5050 Fiber/Duct Joint Closure Large cabinet suitable for fiber splicing and termination of up to 192 microducts or drop cables. The supplied fiber organizers can typically handle up to 384 fibers. Type: Indoor cabinet, 19, ETSI or wall mount Size: 440x600x220mm Sealing: IP class 45 Capacity: 384 splices, 192 microducts Acid-proof, stainless steel joint closure suitable for outdoor, direct buried installations. With a capacity of up to 48 microducts and three cable inlets, it is a good alternative to larger above-ground jointing cabinets. Generously-sized fiber organizers also cater for fused fiber splitters for PON network applications. The closure can also be used in the Micronet system. Type: Outdoor stainless steel closure for cables and microducts Size: Ø270, height 140mm Sealing: IP class 68 Capacity: 144 single splices, 48 microducts 1/NCD507200 and 2/NCD507200 Fiber Access Terminal, Indoor or outdoor NCD 502 6001+ Fiber/Duct Joint Closure FATs for indoor or outdoor applications with up to 24 end-user connections in the drop network. It can handle air-blown fiber in microducts, micro cables as well as drop cables and other fiber optic cables. It can also be used as a fiber optic splice box for various applications. Type: Indoor closure, wall mount. Outdoor closure, wall or pole mount Size: 368x275x114mm Sealing: (indoor) IP class 54, (outdoor) IP class 56 Capacity: 24 connectors (SC) Plastic joint closure for wall mounting, suitable for outdoor, above-ground, protected areas or for indoor use. The closure can house smaller to medium fiber counts. It has two central cable inlets for incoming cables and 20 additional smaller inlets distributing up to 24 microducts or drop cables. All inlets are equipped with flexible rubber gaskets. Type: Outdoor/Indoor closure, wall mount Size: 288x178x77mm Sealing: IP class 45 Capacity: 48 splices, 24 microducts 26 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 27

Installation Tools and Accessories LTT 179 2000 Air Blown Fiber (ABF) Installation Tool LDK 1951 Single Sheath Cutter This unique, easy-to-use lightweight tool has been designed for optimal performance when installing Ericsson s EPFUs. The tool is delivered with a case and all necessary accessories, including two batteries, a charger and calibration tools. Type: Air blown fiber (ABF) installation Supported products: Ericsson 1-8 fiber EPFU 3-8mm microducts Capacity: 100m/min A small and handy tool primarily for removing single-sheathed ducts. Type: Single sheath cutter NTM 502 06+ Blowing Beads LDK 19503 Micro Cable Sheath Cutter Beads that can be mounted on the tip of the air blown fiber unit for optimal blowing. This is recommended for long installation distances with many duct connectors or sharp bends. The beads come in two different sizes to suit the different EPFUs. Type: Blowing bead for EPFU Used for removal of the sheath on micro cables. The tool is delivered with three straight and one round blade. Cutting depth is adjustable. Type: Micro cable sheath cutter NTM 502 07 Cleaning Sponges LDK 208 03 Microduct Cutter Cleaning sponges are used when cleaning dust or moisture from a microduct. The sponge is simply blown through the microduct by the air pressure from the installation tool. Type: Cleaning sponge for 5/3,5mm ducts Provides a clean and straight cut necessary to perform a smooth duct splice prior to the mounting of microduct snap-in connectors. Type: Microduct cutter LDK 195 02 Duct Sheath Cutter LDK 302 04 Stripping Tool for EPFU and CFU Used for quick and easy removal of any sheath from multiducts, this is an excellent tool for performing mid-span access on ducts. Type: Sheath cutter Capacity: 1-24-way Ribbonet 1-7-way Micronet Used for removal of the acrylate coating on EPFU air blown fiber units or compact fiber units in aerial micro cables. Type: EPFU, CFU stripper LDK 195 01 Double Sheath Cutter Cutter to use when dismantling the outer sheath of a double-sheathed HDPE multiduct (direct buried). Type: Outer sheath cutter 28 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 29

Drop Cables Designed for quick and easy installation Ericsson Drop Cables connect end users in FTTx networks to a nearby Fiber Access Terminal. Drop cables are usually a good choice for shorter distances and where there is easy access for the cable installation. To facilitate installation and minimize attenuation when cable is installed around sharp corners, all Ericsson drop cables are based on extra bend resistant G657A2 fiber. The fiber is compatible with standard G652D fiber used in feeder and distribution cables. Drop Cable, aerial, In/Outdoor Self-supporting figure-8 drop cable with loose tube design for aerial installation. The cable suspension wire can be cut and anchored while the cable part can continue indoors. Type: Aerial figure-8, in-/outdoor, halogen-free, flame-retardant Capacity: 1-12 fibers Diameter: 4x8mm Fiber Type: G657A2 TOL 406 3006 and TOL 406 3007 GNGQBDU Drop Cable, Indoor or In/Outdoor Halogen-free, flame-retardant drop cables with tight secondary coated fiber for quick and easy splicing and fitting of connectors. The cable is designed with G657B extra high bend-resistant fiber and a robust design to facilitate mounting with brackets directly on the wall. The white cable is for indoor use and the black for both in/outdoor. Type: Direct installation Capacity: 1-4 fibers Diameter: 4.8mm to be used with cable clamps Fiber Type: G657A2 TOL 405 9005+ GNGQBDU Drop Cable, Indoor Halogen-free, flame-retardant drop cable with loose tube design for FTTx applications. The cable is used for both vertical (riser) and horizontal installations in buildings. To facilitate installation, G657B extra high bend-resistant fiber is used. Type: Halogen-free, flame-retardant Capacity: 1-12 fibers Diameter: 3.95mm Fiber Type: G657B (G652D compatible) Drop Cable, Indoor Extra slim drop cable with excellent bend-performance, for indoor installations in cable chutes or directly on the wall with cable clamps. Fits easily to standard connectors bend protection. Type: Halogen-free, flame-retardant Capacity: 1 fiber Diameter: 2.8mm Fiber Type: G657A2 (G652D compatible) TOL 406 9001 GNGQBDU Drop Cable, Outdoor Durable loose tube drop cable for outdoor installation in ducts or direct-buried. A perfect cable to use in last drop to FSU. Two FRP-rods guarantee highest crush performance. Type: Duct or direct-buried, halogen-free Capacity: 1-12 fibers Diameter: 6.1x3.3mm Fiber Type: G657A2 30 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 31

Fiber Termination Boxes and O/E Conversion Ericsson Fiber Termination Boxes (FTBs) and O/E conversion units are used at enduser premises, such as homes and offices and provide easy-to-install equipment with good fiber protection in esthetic but discrete designs. Fiber Transport Network Fiber optic cables for indoor and outdoor applications The fiber transport site related offering incorporates a range of fiber optic cables, joint closures and accessories for all kinds of network and interconnect applications. All products have been designed and tested for optimal installation functionality, as well as resistance to fire, chemicals and environmental damage. NEG 203 100 Fiber Termination Box FTB to be used as a multi-purpose fiber demarcation point for FTTH and FTTD applications, for a flexible and truly future-proof solution. At any time, the adapter plate can be replaced with a miniature media converter module, transforming the passive wall outlet into an active fiber optic media converter. An internal tray with a snap-on lid protects excess fibers and a multi connector adapter plate enables a capacity of 1-6 fiber optic connectors. Type: FTTH/FTTD Fiber Optic Termination Box, Indoor use Dimensions: 120x100x36mm Capacity: 1-3xSC, 1-6xLC Outdoor Installations Cables for Duct Installation The range of cables for duct installation includes all our five basic designs: concentric core, slotted core, slotted core ribbon, DryTech TM and ribbon in loose tubes. The duct installation cables include both metallic and dielectric cables with fiber counts of up to several hundred fibers. The fibers can be of different types and different types of fiber can be mixed in the same cable. The duct cables can be supplied with aluminum foil as a moisture barrier. Aramid or glass yarn can be added for extra axial pulling strength. Glass yarn or polyamide can be used as protection against rodents. KDU 137 468/1 Fiber Optic Converter OPW 120 TOL 401 2084 GRCLDV The OPW 120 is a universal fiber optic media converter for FTTH and FTTD applications. With its unique design and advanced features, the OPW 120 provides a truly future-proof solution for all Ethernet-based broadband networks. Completely plug and play, the OPW 120 requires no configuration by the user to get it up and running. Type: Media converter with cover 100BaseBX to 100BaseTX, single fiber Dimensions: 120x100x36mm (exterior cover) 80x65x23mm (media converter module) Capacity: 100Mbps, 20 km reach (typical) Slim loose tube cable with concentric core design, with up to six tubes per cable. The cable is all dielectric. DryTechTM filling compound is used in the cable core. Design: Concentric core, extra slim Type: Dielectric, DryTech TM Capacity: 1-48 fibers Diameter: 10mm NEG 204 5970/040 Fiber Termination Box FTTD TOL 401 2098 GRCLDV This fiber outlet is intended for the termination of optical fiber in FTTD applications using fixed trunk networks. The outlet fits into a separate fiber protective casing (accessory) mounted in the cable trunk. The casing contains snap-in holders for microducts or drop cables. A selection of mounting plate panels for different connector standards is available. Type: FTTD Fiber Optic Termination Box, Indoor use Dimensions: 85x85x30mm Capacity: 2xSC, 4xLC, 2xMT-RJ Slim loose tube cable with concentric core design, with up to six tubes per cable. The cable is all dielectric. DryTechTM filling compound is used in the cable core. Design: Concentric core, extra slim Type: Dielectric, DryTech TM Capacity: 12-288 fibers Diameter: 11-18.5mm 5/NEG 203 200 Fiber Termination Box FTB designed for termination of fibers outside premises in FTTx applications. The box terminates and protects fiber or duct connections for the final drop cabling. It can also be used as a multipurpose outdoor fiber optic wall outlet. The box is suitable for both air blown fiber installations and drop cables. Type: FTTH Fiber Optic Termination Box, Outdoor/indoor use Dimensions: 190x130x45mm Sealing: IP class 54 Capacity: 4xSC, 4xLC TOL 401 2017 GRCLDV Loose tube cable with concentric core design, resulting in a cost-effective solution. The cable is all dielectric. DryTech TM filling compound is used in the cable core. Maximum capacity is 16 tubes with 12 fibers in each. Design: Concentric core Type: Dielectric, DryTech TM Capacity: 2-192 fibers Diameter: 11-23mm 32 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 33

TOL 401 2064 GRCALV TOL 401 1013 and TOL 401 1001 GASLDV Loose tube cable with concentric core design and aluminum foil, which provides an excellent moisture barrier, making the cable suitable for humid environments. DryTech TM filling compound is used in the cable core. Maximum capacity is 16 tubes with 12 fibers in each. Design: Concentric core Type: Aluminum barrier, DryTech TM Capacity: 2-192 fibers 4-fiber ribbon cable using slotted core design. The design reduces installation costs and gives superior fiber protection. The cable is dielectric, making it suitable for installation where there is electrical interference. Design: Slotted core ribbon Type: Dielectric Capacity: Ø9.5mm 4-48 fibers Ø12.5mm 4-48 fibers Ø14mm 48-96 fibers TOL 401 2044 GRCGLDV TOL 401 1002 and TOL 401 1020 GASLDV Loose tube cable with concentric core design and aramid yarn for extra pulling strength. The cable is all dielectric. DryTech TM filling compound is used in the cable core. Maximum capacity is 16 tubes with 12 fibers in each. Design: Concentric core Type: Dielectric, DryTech TM, aramide reinforced Capacity: 2-192 fibers 8-fiber ribbon cable using slotted core design. The design allows high packing density that reduces installation costs and gives superior fiber protection. Water-blocking filling compound in the TOL 401 1002 cable and dry water-blocking tape in the TOL 410 1020 cable prevents water penetration along the cables. The cable is dielectric, making it suitable for installation where there is electrical interference. Design: Slotted core ribbon Type: Dielectric Capacity: Ø15.5mm 8-192 fibers Ø20-22.5mm 288-640 fibers TOL 401 2012 GRHLDV TOL 401 1018 GASALV Loose tube cable with concentric core design, resulting in a cost-effective solution. The cable is dielectric, making it suitable for environments with a high risk of electrical interference. Maximum capacity is 12 tubes with 12 fibers in each. Design: Concentric core Type: Dielectric, slim, low weight Capacity: 2-144 fibers 4-fiber ribbon cable using slotted core design, which reduces installation costs and gives superior fiber protection. The cable uses 4-fiber ribbons. Aluminum foil provides an excellent moisture barrier, making the cable suitable for humid environments. Design: Slotted core ribbon Type: Aluminum barrier Capacity: 4-96 fibers TOL 406 9001 GNGQBDU Drop Cable, Outdoor TOL 401 1019 GASALV Durable loose tube drop cable for outdoor installation in ducts or direct-buried. A perfect cable to use in last drop to FSU. Two FRP-rods guarantee highest crush performance. Type: Duct or direct-buried, halogen-free Capacity: 1-12 fibers Diameter: 6.1x3.3mm Fiber Type: G657A2 8-fiber ribbon cable with slotted core design, which reduces installation costs and gives superior fiber protection. The cable uses 8-fiber ribbons. Aluminum foil provides an excellent moisture barrier, making the cable suitable for humid environments. Design: Slotted core ribbon Type: Aluminum barrier Capacity: 8-192 fibers TOL 401 9017+ GNHLDV Micro Cable Micro cable based on a slim loose tube design with up to eight tubes per cable. The design facilitates fiber preparation and mid-span access. The cable is suitable for long-distance, air blown installation in microducts, with an inner diameter of as little as 8mm. The cable has excellent bend performance. Design: Loose tube Type: Dielectric, slim Capacity: 12-96 fibers 34 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 35

Cables for Direct Buried Installation The range of cables for direct buried installation includes all our five basic designs: concentric core, slotted core, slotted core ribbon, DryTech TM and ribbon in loose tubes. The cables for direct buried installation are reinforced with corrugated steel tape, steel wire, or foamed thermoplastic elastomer, providing excellent mechanical protection. The range of cables includes both metallic and dielectric cables and covers fiber counts up to several hundred fibers. TOL 402 2023 GRCLTLV Loose tube cable with concentric core design, a layer of steel wire armoring and a second outer sheath. The steel wire gives a heavy duty armoring, enabling installation in rough terrain and operational reliability under severe conditions. DryTech TM filling compound is used in the cable core. Maximum capacity is 16 tubes with 12 fibers in each. Design: Concentric core Type: Steel wire armoring, high tensile strength, DryTech TM Capacity: 4-192 fibers GRCLWLV, slim TOL 402 2002 GRHLWLV Slim loose tube cable with concentric core design, a corrugated steel tape layer and a second outer sheath. The corrugated steel tape reinforcement provides good mechanical protection, but the cable is still easy to install. DryTechTM filling compound is used in the cable core. Maximum capacity is 24 tubes with 12 fibers in each. Design: Concentric core Type: Corrugated steel tape reinforced, DryTech TM Capacity: 12-288 fibers Diameter: 17-24mm Loose tube cable with concentric core design, a corrugated steel tape layer and a second outer sheath. The corrugated steel tape provides good mechanical protection, yet the cable is still easy to install. Maximum capacity is 12 tubes with 12 fibers in each. Design: Concentric core Type: Corrugated steel tape reinforced Capacity: 4-144 fibers TOL 402 2025 GRCLWLV TOL 402 2019 GRHLLDV Loose tube cable with concentric core design, a corrugated steel tape layer and a second outer sheath. The corrugated steel tape reinforcement provides good mechanical protection, but the cable is still easy to install. DryTech TM filling compound is used in the cable core. Maximum capacity is 16 tubes with 12 fibers in each. Design: Concentric core Type: Corrugated steel tape reinforced, DryTech TM Capacity: 4-192 fibers Loose tube cable with concentric core design, a thermoplastic cushion layer and a second outer sheath. The thermoplastic cushion layer makes the non-metallic cable suitable for installation along power lines, e.g. railway embankments. DryTech TM filling compound is used in the cable core. Maximum capacity is 12 tubes with 12 fibers in each. Design: Concentric core Type: Dielectric, thermoplastic cushion layer Capacity: 4-144 fibers GRCLLDV, slim, dielectric TOL 402 1014 GASQWQBUV Slim loose tube cable with concentric core design, a thermoplastic cushion layer and a second outer sheath. The thermoplastic cushion layer makes the non-metallic cable suitable for installation along power lines, e.g. railway embankments. DryTechTM filling compound is used in the cable core. Maximum capacity is 24 tubes with 12 fibers in each. Design: Concentric core Type: Dielectric, thermoplastic cushion layer, DryTech TM Capacity: 12-288 fibers Diameter: 18-25mm Ribbon cable with slotted core design and corrugated steel tape protection providing superior fiber protection against rodents. Ideal for duct and direct buried installation in tunnels. The cable comes in two configurations; up to 96 fibers with 4-fiber ribbons and more than 96 fibers with 8-fiber ribbons. Design: Slotted core ribbon Type: Corrugated steel tape reinforce, high crush resistance Capacity: 96-640 fibers TOL 402 2011 GRCLLDV TOL 402 1002 GASLWLV Loose tube cable with concentric core design, a thermoplastic cushion layer and a second outer sheath. The thermoplastic cushion layer makes the non-metallic cable suitable for installation along power lines, e.g. railway embankments. DryTech TM filling compound is used in the cable core. Maximum capacity is 16 tubes with 12 fibers in each. Design: Concentric core Type: Dielectric, thermoplastic cushion layer, DryTech TM Capacity: 4-192 fibers 4-fiber ribbon cable with slotted core design, a corrugated steel tape layer and a second outer sheath. The corrugated steel tape reinforcement provides good mechanical protection, but the cable is still flexible enough for easy installation. Design: Slotted core ribbon Type: Corrugated steel tape reinforced Capacity: 4-96 fibers 36 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 37

TOL 402 1010 GASLWLV 8-fiber ribbon cable with slotted core design, a corrugated steel tape layer and a second outer sheath. The corrugated steel tape reinforcement provides good mechanical protection, but the cable is still flexible enough for easy installation. Design: Slotted core ribbon Type: Corrugated steel tape reinforced Capacity: 8-192 fibers Cables for Aerial Installations Self-supporting aerial fiber cables Ericsson s range of Fiber Optic Cables for aerial installation includes self-supporting All Dielectric Self Support (ADSS) and figure-8 types, designed for pole installation. The cables come in different span lengths and can handle several hundred fibers. All ADSS and figure-8 cables can be supplied with extra protection against rodents (nylon sheath), or shotguns (aramid tape). Ericsson also offers a complete range of installation support material for aerial cables. TOL 402 1001 GASLLDV TOL 403 2003 GRHSLDV 4-fiber ribbon cable with slotted core design, a thermoplastic cushion layer and a second outer sheath. The thermoplastic cushion layer makes the non-metallic cable suitable for installation along power lines, e.g. railway embankments. Design: Slotted core ribbon Type: Dielectric, thermoplastic cushion layer Capacity: 4-96 fibers ADSS, non-metallic cable with concentric core design. This extremely slim and low-weight cable, which can be ordered with 4 to 144 fibers, is suitable for span lengths from 60-170m. It can be installed adjacent to power lines with up to 120 kv. It contains standard filling compound and utilizes aramid yarn to increase strength. Design: ADSS, concentric core Type: Dielectric Capacity: 4-144 fibers TOL 402 1005 GASLLDV TOL 403 2002 GRHSLLDV 8-fiber ribbon cable with slotted core design, a thermoplastic cushion layer and a second outer sheath. The thermoplastic cushion layer makes the non-metallic cable suitable for installation along power lines, e.g. railway embankments. Design: Slotted core ribbon Type: Dielectric, thermoplastic cushion layer Capacity: 8-192 fibers ADSS, non-metallic cable with concentric core design that utilizes aramid yarn and a second outer sheath for an extra robust cable design. It is suitable for installation in harsh climates with high ice loads, and for span lengths of 100-250m. Like the GRHSLDV, this cable contains standard filling compound and can be ordered with 4 to 144 fibers. Design: ADSS, concentric core Type: Dielectric Capacity: 4-144 fibers, max 7kN TOL 403 2008 GRHSLLDV ADSS, non-metallic cable with concentric core design that utilizes aramid yarn and a second outer sheath for an extra robust cable design. It is suitable for installation in harsh climates with high ice loads, and for span lengths of 200-500m. Like the GRHSLDV, this cable contains standard filling compound and can be ordered with 4 to 144 fibers. Design: ADSS, concentric core Type: Dielectric Capacity: 4-144 fibers, max 14.5kN TOL 403 2024 GRCLCV Self-supporting figure-8 cable with concentric core design. The cable has patented DryTech TM filling compound and includes suspension steel wire integrated into the sheath. The cable is suitable for span lengths up to 75m. The GRCLCV can be ordered with 4 to 192 fibers. Design: Fig-8, concentric core Type: DryTech TM Capacity: 4-192 fibers 38 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 39

TOL 403 2010 GRCLCDV Non-metallic figure-8 cable using concentric core design, with a glass-fiber reinforced plastic rod integrated into the sheath. The self-supporting c able is suitable for span lengths of up to 75m. Being dielectric, the cable can be installed adjacent to power lines with up to 120kV. The GRCLCDV can be ordered with 4 to 192 fibers. Design: Fig-8, Concentric core Type: Dielectric Capacity: 4-192 fibers Joint Closures for fiber optic cables Joint closures for optimal protection Utilizing its broad experience in information network installation and operation, Ericsson has developed a range of cost-effective joint closures that provides the right quality in the right place. The offering, for both indoor and outdoor installation, includes boxes optimized for virtually all conditions, and for small, medium and large fiber counts. Made in a variety of materials to suit environments ranging from simple to very demanding, the boxes are designed to join most types of fiber cables. Ericsson offers a complete line of accessories, including tool kits, protection sleeves, shrink-on hoses, mounting brackets and expansion kits, suitable for various types of installation. NCD 504+ Fiber Joint Closure Versatile fiber closure made of durable plastic to meet most environmental demands. The standard box can handle up to 96 single fibers or 48 ribbon sleeves, and is expandable to manage higher fiber counts and a greater number of entrances. The closure can also handle mid-span access. Type: Underground, plastic Sealing: IP class 68 Capacity: 96 single fiber splices or 48 ribbon fiber splices with 4 extra cassettes. Up to 144 single splices with extension ring and 8 extra cassettes. NCD 503+ Fiber Joint Closure Closure made of acid-proof stainless steel to withstand the harshest environments. The standard box can handle up to 72 single fibers or 36 ribbon sleeves, and is expandable to manage higher fiber counts and a greater number of entrances. The closure can also handle mid-span access. Type: Underground, stainless steel Sealing: IP class 68 Capacity: 72 single fiber splices 36 ribbon fiber splices NCD 506+ Fiber Joint Closure Closure for higher fiber counts in harsh outdoor environments. The generous size of the fiber organizers makes installation fast and trouble free. The design is compact but easy to expand to accommodate very large fiber counts. The closure can also handle mid-span access. Several versions and accessories are available resulting in a total capacity of 144 fibers to more than 2000 fibers depending on configuration. Type: Underground, stainless steel Sealing: IP class 68 Capacity: 576 single fiber splices 288 ribbon fiber splices 40 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 41

NCD 502 6001 Fiber Joint Closure Wall-mounted, splash-proof closure, made of plastic and suitable for indoor use or mounting outdoor in above-ground protected areas. It can manage up to 24 microducts for air blown fibers or 24 drop cables, or can just as easily be used for joining together two fiber optic cables, or a combination of the two. The fiber organizers can handle up to 48 single fibers. NCD 502 5000 Fiber Joint Closure Compact indoor closure that provides mechanical protection in situations where jointing and branching of cables needs to be carried out costeffectively. It can be mounted inside a cabinet, container or directly on a wall. Type: Outdoor/Indoor closure, wall mount Size: 288x178x77mm Sealing: IP class 45 Capacity: 48 splices, 24 microducts Type: Indoor, alu-zinc Size: 369x185x40mm Capacity: 24 single fiber splices 12 ribbon fiber splices Submarine Installation Submarine cables based on extensive experience Ericsson s range of cables for submarine installation is based on extensive experience in submarine-cable projects, including design, project management and installation. The offering comprises cables using unitube loose fiber design for depth down to 2000m. All cables have steel wire armoring, in one or several layers, and a copper or stainless steel tube to provide superior mechanical and water blocking properties. The cables are resistant to tensile forces and impact caused by anchoring, recovery operations and handling. TOL 404 1050 GJMLTV, 10-ton SA Single-armored, unitube cable where moderate protection is required in submarine applications. This design includes a hermetically sealed stainless tube (3.7mm outer diameter). Inside the tube the fibers are free to move in the thixotropic water blocking compound. The tube is protected by a polyethylene sheath, one layer of galvanized steel wires and wrapped in a layer of polypropylene yarn. The unitube technique results in a high packing density. This permits a small outer diameter and easy handling. Design: FIMT, single armor Type: 10 ton, 2000m Capacity: 1-48 fibers TOL 404 1051 GJMLTV, 15-ton DA Double-layer armored, unitube cable where high protection is required in submarine applications. This design includes a hermetically-sealed stainless tube (3.7mm outer diameter). Inside the tube the fibers are free to move in the thixotropic water blocking compound. The tube is protected by a polyethylene sheath, two layers of galvanized steel wires and wrapped in a layer of polypropylene yarn. Design: FIMT, double armor Type: 15 ton, 2000m Capacity: 1-48 fibers TOL 404 1062 GJMLTV, 25-ton DA Double-layer armored, unitube cable with the same principal design as the GJMLTV, 15-ton DA above. Design: FIMT, double armor Type: 25 ton, 2000m Capacity: 1-48 fibers 42 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 43

TOL 404 1054 GJMLTV, 40-ton DA TOL 404 1043 and TOL 404 1041 GASLMLTV, 20-ton RA Double-layer armored with the same principal design as the GJMLTV, 15-ton DA above. Design: FIMT, double armor Type: 40 ton, 2000m Capacity: 1-48 fibers Rock-armored cables for submarine applications where the cable is exposed to severe mechanical wear and tear. These could include installation directly on rock or shore landings where the cable is subject to forces such as waves or tides. The three layers of steel wire reinforcement provide heavy-duty mechanical protection, enabling installation during rough conditions and reliable operation in severe conditions. Design: Slotted core ribbon, triple armor Type: 20 ton, 500m Capacity: 4-96 fibers (4-f ribbon) 8-192 fibers (8-f ribbon) TOL 404 1010 and TOL 404 1038 GASLMLTV, 5-ton SAL TOL 404 1002 and TOL 404 1042 GASLMLTV, 40-ton DAH Single-armored light, 4- or 8-fiber ribbon cable where light to moderate protection is required in submarine applications. The ribbon technique results in a high packing density. This permits a small outer diameter and fast splicing for cables with a high fiber count. The slotted core cable has high crush load resistance due to the radial shape of the slotted core profile. Design: Slotted core ribbon, single armor Type: 5 ton, 500m Capacity: 4-96 fibers (4-f ribbon) 8-192 fibers (8-f ribbon) Double-armored, heavy 4- and 8-fiber ribbon cables where extra-high protection is required in submarine applications. For example, landings, where no additional protection, such as articulated pipes, is available. It has a similar design to the GASLMLTV, 5-ton. The maximum NTTS is 400 kn. Design: Slotted core ribbon, double armor Type: 40 ton, 500m Capacity: 4-96 fibers (4-f ribbon) 8-192 fibers (8-f ribbon) TOL 404 1016 and TOL 404 1039 GASLMLTV, 10-ton SA NCD 601 0014 Submarine Joint Closures Single-armored ribbon cable with the same principal design as the GASLMLTV, 5-ton SAL version above. The maximum NTTS is 100 kn. Design: Slotted core ribbon, single armor Type: 10 ton, 500m Capacity: 4-96 fibers (4-f ribbon) 8-192 fibers (8-f ribbon) Closure made of heavy-duty stainless steel and hermetically-sealed cable joints for GJMLTV (FIMT) fiber optic submarine cables. The joint can host up to 48 fibres. Design: Straight joint for GJMLTV Capacity: 1-48 fibers TOL 404 1023 GASLMLTV, 15-ton SAH NCD 601 0014 Submarine Joint Closures Single-armored heavy cable with the same principal design as the GASLMLTV, 5-ton SAL. The maximum NTTS is 150kN. Design: Slotted core ribbon, single armor Type: 15 ton, 500m Capacity: 4-96 fibers (4-f ribbon) 8-192 fibers (8-f ribbon) Closure made of heavy-duty stainless steel and hermetically-sealed cable joints for GJMLTV (FIMT) fiber optic submarine cables. The joint can host up to 48 fibres. Design: Straight joint for GJMLTV Capacity: 1-48 fibers TOL 404 1011 GASLMLTV, 20-ton DA NCD 601+ Universal Joint for Submarine Cables Double-armored cable with the same principal design as the GASLMLTV, 5-ton. The maximum NTTS is 200kN. Design: Slotted core ribbon, double armor Type: 20 ton, 500m Capacity: 4-96 fibers (4-f ribbon) 8-192 fibers (8-f ribbon) Universal Joint is a technology developed by the Universal Joint Consortium to facilitate efficient maintenance of installed submarine cable systems. Many of Ericsson s submarine cables are qualified for this technology and for some cable types this joint type is used in installation projects of new systems. Design: Design: UJ for 10-, 25-, 40 ton submarine cables 44 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 45

Local Site Cabling Cables for Indoor Installation The range of indoor installation cables is recommended for use in telecommunication stations for interconnection between the optical line interface and the optical distribution frames. The indoor cables are also suitable for use in LAN networks or other types of data networks. All indoor cables are halogen-free and flame-retardant, and consequently generate no corrosive gases during combustion. All cables are also completely dielectric. The fibers in the cable can be of different types and different fiber types can be mixed in the same cable. TOL 405 3018 GNGQQBDU, 4-fiber Break-out cable where simplex cables are put into one cable, with aramid yarn as central strength member. The construction results in a robust cable combined with high flexibility. The cable can be delivered pre-terminated with a variety of connector types. Design: Tight-buffered, break-out Type: Halogen-free, flame-retardant Capacity: 4 fiber TOL 405 3001/1 GNGQBDU, 1-Fiber Simplex, buffered patch cord cable, non-jelly filled with an outer diameter of 2.0mm as standard. It can be delivered pre-terminated with a variety of connector types. The cable has low shrinkage of less than 0.5% for reliable high performance. Design: Tight-buffered Type: Halogen-free, flame-retardant, IEC60332-3 cat C (LSZH), UL 1666 (CMR/Riser) Capacity: 1 fiber TOL 405 3001/2 GNGQBDU, 2-fiber Two-fiber, tight-buffered duplex patch cord cable, non-jelly filled and aramid reinforced. The cable has a figure-8 design with single fibers laid in parallel, which makes it easy to split into two simplex patch cables. Design: Tight-buffered Type: Halogen-free, flame-retardant, IEC60332-3 cat C (LSZH), UL 1666 (CMR/Riser) Capacity: 2 fiber TOL 405 3006 GNGQQBDU, 2-fiber Two fiber, tight-buffered duplex patch cord cable, non-jelly filled and aramid reinforced. Two single fiber cables are enclosed in an outer sheath forming a flexible and dry cable with an outer dimension of 4.8x2.8mm. It can be delivered preterminated with a variety of connector types. Design: Tight-buffered, break-out Type: Halogen-free, flame-retardant, IEC60332-3 cat C (LSZH), UL 1666 (CMR/Riser) Capacity: 2 fiber TOL 405 3013 GNHQBDUV Distribution cable suitable for longer distances and humid areas. A concentric core design make this tight-buffered fiber cable cost-effective and slim. Tape is used instead of jelly as longitudinal water blocking, making the jointing procedure clean and easy. Design: Concentric core, Tight-buffered Type: Halogen-free, flame-retardant Capacity: 2-12 fiber 46 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 47

Cables for Indoor/Outdoor Installation The cables for combined indoor/outdoor installation are all halogen-free and flameretardant; consequently, no corrosive gases are generated during combustion. The cables cover fiber counts that meet common building practices within the telecom industry. The fibers can be of different types and different fiber types can be mixed in the same cable. The indoor/outdoor cables are often used between a pre-terminated indoor optical distribution frame and an outdoor joint closure. The cable sheaths should be protected from direct sunlight and moisture, and good drainage is recommended for outdoor installation in short lengths. TOL 405 1014 GASQBDUV Ribbon cables with slotted core design which enables a cable design with reduced installation cost and superior fiber protection. Each of the six slots contains 1-2 ribbons of the 4-fiber ribbon type. The cable is dielectric, very slim and flexible, making it very versatile. Dry water blocking makes the cable jointing procedure clean and easy. The cable is offered in two variants: standard and extra slim. Design: Slotted core ribbon Type: Dielectric, halogen-free, flame-retardant Capacity: Ø9.9mm, 4-48 fibers TOL 406 3006 and TOL 406 3007 GNGQBDU Drop Cable, Indoor or In/Outdoor TOL 405 1024 GASQBDUV Halogen-free, flame-retardant drop cables with tight secondary coated fiber for quick and easy splicing and fitting of connectors. The cable is designed with G657B extra high bend-resistant fiber and a robust design to facilitate mounting with brackets directly on the wall. The white cable is for indoor use and the black for both in/outdoor. Type: Direct installation Capacity: 1-4 fibers Diameter: 4.8mm to be used with cable clamps Fiber Type: G657A2 4 or 8-fiber ribbon cable with slotted-core design providing superior fiber protection and high fiber count. Each of the slots contains ribbons of 4 or 8 fibers. The 8-fiber ribbon can easily be split into two 4-fiber ribbons. The versatility of the cable and the inherent benefits of ribbon fiber technology reduce installation costs. The cable is provided in two configurations: 96 fibers with 4-fiber ribbons and >96 fibers with 8-fiber ribbons. Design: Slotted core ribbon Type: Dielectric, halogen-free, flame-retardant Capacity: 72-96 fibers (4-f ribbon) 192-640 fibers (8-f ribbon) TOL 405 2003 GRHQBDUV Loose tube cable with concentric core design, resulting in a cost-effective solution. Each tube contains up to 12 fibers and the cable contains up to 16 tubes. Dry water blocking makes the cable jointing procedure clean and easy. Design: Concentric core Type: Dielectric, halogen-free, flame-retardant Capacity: 4-144 fibers TOL 405 9009 GNGQBDUV, high temperature performance Fiber optic cable designed for FTTA applications in both indoor and outdoor environments. This cable has extremely good heat resistance and operates -40 to +95(degrees)C. The cable is flame resistant so it can be installed indoors at the same time the outer sheath is robust enough to cope with outdoor environments. It is suitable for pre-terminated delivery. Design: Tight-coated, with aramid yarn Type: Dielectric, halogen-free, flame-retardant, bend resistant G657.A2* Capacity: 2 fibers * Compatible with G652D TOL 406 3004 GNGQQBDV TOL 406 3008 GNGQBDUV Fiber optic cable designed for FTTA applications in both indoor and outdoor environments. The cable is flame resistant. Water blocking tape guarantees that no water can pass through the cable and the outer sheath is specially designed for highest protection in outdoor environments. The cable is suitable for pre-terminated delivery and has extremely good bending performance due to the use of bend- resistant G657B fiber. Design: Tight-buffered Type: Dielectric, halogen-free, flame-retardant, bend resistant G657B* Capacity: 2 fibers * Compatible with G652D Fiber optic cable designed for FTTA applications in both indoor and outdoor environment. Water blocking aramid yarns guarantees that no water can pass through the cable and the outer sheath is specially designed for highest protection in outdoor environments It is suitable for pre-terminated delivery. Design: Tight-coated, with aramid yarn Type: Dielectric, halogen-free, flame-retardant, G652.D Capacity: 2 fibers TOL 405 1001 GASQBDUV Ribbon cables with slotted core design, which reduces installation costs and ensures superior fiber protection. Each of the six slots contains 1-2 ribbons of the 4-fiber ribbon type. The cable is dielectric, and very slim and flexible, making it very versatile. Dry water blocking makes the cable jointing procedure clean and easy. The cable is offered in two variants: standard and extra slim. Design: Slotted core ribbon Type: Dielectric, halogen-free, flame-retardant Capacity: Ø13mm, 4-48 fibers 48 For more detailed information and data sheets, please visit the Ericsson Product Catalog at www.ericsson.com see Our Portfolio/Products/Cables and Interconnect 49

Abbreviations ADSS ABF CPE EPFU FAT FDH FIMT FRP FTB FTTA FTTB FTTC FTTH FTTx LAN NTTS MMS ODF O/E PON P2P P2MP RoHS All Dielectric Self Support Air Blown Fiber Customer Premises Equipment Enhanced Performance Fiber Unit Fiber Access Terminal Fiber Distribution Hub Fiber in Metallic Tube Fiber Reinforced Plastic Fiber Termination Box Fiber-to-the-Antenna Fiber-to-the-Building Fiber-to-the-Curb Fiber-to-the-Home For generic use in fiber networks Local Area Network Nominal Transient Tensile Strength Multifiber Management System Optical Distribution Frames Optical/Electrical Passive Optical Network, also called P2MP Point-to-point Point-to-multipoint Restriction of Hazardous Substance 50

Ericsson is shaping the future of Mobile and Broadband Internet communications through its continuous technology leadership. Providing innovative solutions in more than 140 countries, Ericsson is helping to create the most powerful communication companies in the world. Ericsson AB Cables & Interconnect Torshamnsgatam 39 164 80 Stockholm Sweden Phone: +46 10 719 0000 Ericsson AB Cables & Interconnect Kabelvägen 1 824 82 Hudiksvall Sweden Phone: +46 10 719 0000 The content of this document is subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document Ericsson AB SE-164 80 Stockholm Sweden Phone +46 10 719 0000 www.ericsson.com EN/LZT 108 1613 Rev C Ericsson 2010 All Rights Reserved.