Cabling Technologies Providing More Optical Cabling Potential in Multi-dwelling Unit Buildings
|
|
|
- Victor Benson
- 9 years ago
- Views:
Transcription
1 Cabling Technologies Providing More Optical Cabling Potential in Multi-dwelling Unit Buildings Hayato Minami, Kensei Shiraishi, Tadashi Sasaki, Kazutoshi Takamizawa, Tetsuhiro Numata, and Osamu Inoue Abstract For optical access services to multi-dwelling units (MDUs), we have developed compact optical splitter modules that provide greater installation flexibility and indoor optical cabling that can be installed on the building s exterior walls. They overcome problems encountered in providing optical fiber cabling systems to MDUs and installing splitter modules in the limited space available in maindistributor-frame boxes as well as other difficulties caused by a lack of space in conduits or the absence of conduits. 1. Introduction In June 2010, the number of fiber-to-the-home (FTTH) contracts in Japan surpassed 18 million, heralding the age of ubiquitous optical fiber access. However, since roughly 40% of all households in Japan live in multi-dwelling units (MDUs), such as apartment buildings and condominiums [1], there is growing demand for more adaptable optical cabling systems to provide fiber to households in these sorts of dwellings. In contrast to FTTH cabling schemes for detached houses, which consist of a 4-branch optical splitter in the central office and 8-branch splitter module parts (SPs) installed on the user side (supporting 32 subscribers), schemes for MDUs and office buildings use 32-branch SPs (or a cascade of one 4-branch SP followed by four 8-branch SPs). To date, thin low-friction indoor optical fiber [2] that enables more cables to be installed in conduits and SPs that can be installed in the empty spaces scattered throughout customer buildings (e.g., telephone conduits and main distribution frame (MDF) boxes) [3] have been developed and deployed to expand the range of available cabling systems. They have helped to reduce the number of MDU buildings unsuitable for optical fiber cabling. However, as indicated in Fig. 1, many mediumsized and large MDU buildings have a lack of empty space available in existing MDF boxes etc., and the metallic nature of the hardware already installed means that the conventional SPs cannot be installed easily, and many small MDUs have no conduits or MDF boxes. These conditions make it difficult to provide optical-fiber-based services to such buildings. To tackle these problems, we have developed (1) technologies for installing SPs in MDF boxes in medium-sized MDU buildings, (2) cabling that can be installed on the exterior walls of small MDU buildings, and (3) technologies for installing SPs in large MDU buildings. NTT Access Network Service Systems Laboratories Tsukuba-shi, Japan NTT Technical Review
2 MDU size Small (up to 10 dwellings) Medium (10 to 50 dwellings) Large (50 dwellings or more) Image Yes State of facilities Space in conduits Space in MDF boxes No Large Small None No conduits or MDF boxes No space in MDF box Cabling with thin low-friction indoor optical fiber Conduits exist, but there is no free space. SP FA SP SC cord SP 32 SC SP SC cord FL MDF box has a little space. FA: field assembly FL: flat SC: common type of connector : Areas no applicable products exist Fig. 1. Current state of hardware applications. 2. SP installation technologies for medium-sized MDU buildings Since the SP hardware needs to be small enough to fit into the limited space available in existing MDF boxes, we developed a range of smaller SPs that includes both an ultra-compact SP that can be installed in very small MDF boxes and compact SPs designed to provide better workability and allow more flexible installation methods (Fig. 2). These are described below. 2.1 Ultra-compact SP For SP installation in very small spaces, we further miniaturized the existing SP (called the SC cord FL (flat), shown in Fig. 1) [2]. An overview of the new SP (SC cord S (small/stick)) is shown in Fig. 2. By devising a way to fit the splitter section inside the casing, we reduced the space required for installation by 20%. We also developed multiple alignment members that can be fitted to individual cores, which protect the fiber core connections used for feeding the cord to subscriber residences. 2.2 Compact SPs In dealing with the increasingly diverse cabling forms that result from cabling schemes in optical connection systems used for feeding single-core cable (single-drop optical fibers etc.), it is more efficient to assemble a cable sheath fixing connector (plug type) and terminate it directly at the SP. Moreover, there is a growing need for more versatile attachment methods that do not rely on only ordinary screws, but also enable attachment to metal or plastic. Our new compact SPs (B and C types) are overviewed in Fig. 2. We reduced the space required to maneuver the hardware and install an SP by including input and output sockets and by eliminating the cord section. Unlike conventional equipment where the connectors are secured with screws, these SPs use magnetic attachment to the SP and hinged SP mechanisms. The new design enables much easier detachment and attachment and greatly simplifies the connection work required inside small MDF boxes. 3. External wall cabling technology for small MDUs Some small condominiums do not have an MDF box or conduits available for cabling subscribers desiring optical fiber services. In this situation, a commercially available box is usually attached to the Vol. 9 No. 6 June
3 MDF space Large Very small SP name Conventional (FA type) Compact SP (B type) Compact SP (C type) Ultra-compact SP (SC cord S) Images Mounting images (2) Metal frame mounting (1) Vertical mounting on wood Mounted in very small space Working with the hardware Working with the hardware Fig. 2. Technologies for mounting SPs in MDF boxes in medium-sized MDUs. exterior of the building and the SP is installed inside it. Cabling enters the subscriber s home via the balcony, but this means that work is performed when each individual residence applies for subscription, and negotiations with neighbors are required for permission to work on communal walls (Fig. 3(a)). To address these problems, we have developed a compact box-type SP for attachment to building exteriors and indoor optical fiber bundles that eliminate the need for repeated negotiations with neighbors after the initial application for work. An overview of the hardware is shown in Fig. 3(b). We used the casing for two existing compact attachable boxes (PD and SS types) and it opens and closes in the same way. We designed the units to be resistant to ultraviolet (UV) light and water in order to be suitable for external installation. The indoor optical fiber bundle is a cable consisting of 8 UV-resistant indoor optical fibers pre-twisted helically with suspension members. When an optical fiber is fed into a subscriber residence, one of these optical fiber cores is selected and connected to the sheath grip connector (FA (field assembly) connector [3]) and then laid. These systems can reduce the need for problematic negotiations with neighbors about service connection work. 4. SP installation technologies for large MDUs In cases where there are a large number of prospective users in a large MDU, it is more efficient to batch-install 32-branch SPs rather than the cascades of 4- and 8-branch SPs usually installed in small and medium-sized MDUs. For large MDUs, in addition to installations in the empty space in MDF boxes, there is also demand for 19-inch rack-mounted SPs. Conventional 32-drop SP units are the same height as one 19-inch rack unit (1U), but taking into consideration the space required for maneuvering the input and output cabling, each one needs 3U of free space. Moreover, the installation of more than one conventional 32-drop SP (e.g., to handle 64 or more terminals) in a 19-inch rack requires the use of more than 3U. Therefore, it would be desirable to have more compact hardware that can be installed in a standard 19-inch rack and can make better use of the space available. To ensure enough work space, we reconsidered the pitch between the usual connectors and chose to use a modular scheme that enables the connector sections to be moved horizontally in and out of the chassis. Simply sliding the required section to insert a connector ensures the same level of workability as with the 3 NTT Technical Review
4 (a) Current technology (single-core cabling) Commercial box used because no externally mountable SP available Example of single-drop optical cabling - Cabling performed upon application - Entry via customer s balcony Negotiations with neighbors required for each installation (b) Cabling with the new hardware Externally mountable SP Image Branches 4 or 8 Size 151 mm 153 mm Initial work done in batches; less need for negotiations Multicore indoor optical fiber Fiber core Tension member Suspension member External diameter: 12 mm Feeding method Fig. 3. Comparison of conventional exterior cabling and the new system for small MDUs. Structure comparison 325 mm 180 mm Halved in size 265 mm 180 mm Conventional device New device Workability comparison Attachment pitch: 33 mm Movable connector sections Stopper Max.: 33 mm Range of movement Slide Better port number display to prevent connection mistakes Conventional device New device Fig. 4. Comparison of conventional and new devices (for 32 SPs). Vol. 9 No. 6 June
5 Conventional device New device Mounted in a 19- inch rack 3 rack spaces for 32 terminals 3 rack spaces for 64 terminals Mounting 32 SPs into a 19-inch rack 16 screw attachments to fit 32 SPs into the width of the 19-inch rack 32 SPs fits into 19-inch mounting bracket without tools. Knurled screws do not need tools to tighten them. Easy attachment with slots Fig. 5. Comparison of 19-inch rack mounting procedures. MDU size Small (up to 10 dwellings) Medium (10-50 dwellings) Large (50 dwellings or more) Image Yes Space in conduits No No conduits Cabling with low-friction indoor optical fiber - Technologies for cabling in premises with a lack of conduit space - Technologies for cabling inside customer dwellings State of facilities Space in MDF boxes Large Small None No MDF box SP FA SP SC cord SP SC cord FL SP 32 SC Cabinet technologies developed for new cabling development Cabinet installation in small spaces : Areas more thoroughly covered with these developments : Remaining issues Fig. 6. Areas covered by the new developments and remaining issues. 5 NTT Technical Review
6 conventional devices. We also designed a simple 19-inch rack installation method that does not require the use of specialized tools, unlike the usual hardware that requires many screw attachments to add an expansion SP. An overview of the hardware is shown in Fig. 4. The new device that we have developed (SP 32 SC-S (slide/small)) fits in half the space required for the conventional device, so two of them, supporting 64 subscribers, can be installed in the 3U required to install and work on one conventional unit supporting 32 subscribers. We also developed a 19-inch mounting bracket for the SP inch rack installation (Fig. 5) to which the unit is secured by simply sliding it into position and securing with only two screws at the front. We think that it could reduce work time by up to 80%. We have also aimed for better workability by using knurled screws for tool-free tightening by hand and keyhole-type slot-in screw holes. 5. Further plans These new cabling technologies can improve workability and expand the service provision coverage. However, although the uptake of optical fiber services such as FLET S HIKARI continues at a phenomenal rate, it does not mean that 100% of services can be provided to all subscribers. As shown in Fig. 6, further work is needed to expand services to areas not covered by these new developments. With these new technologies as a base, we plan to continue working to develop indoor cabling technologies that can be applied to all MDUs as well as technologies that streamline the installation work required for optical fiber access services. References [1] Statistics Bureau, Ministry of Internal Affairs and Communications, Housing and Land Survey [2] S. Niwa, H. Minami, K. Takamizawa, Y. Takeshita, and T. Handa, Development of New Optical Wiring Technology for Multi-dwelling Unit Buildings, NTT Technical Review, Vol. 7, No. 9, le1.html [3] K. Takamizawa, H. Aoyama, O. Inoue, Y. Oda, S. Matsui, and H. Minami, Improving Cabling and Connection Workability in Multidwelling Units, NTT Technical Journal, Vol. 20, No. 12, pp , 2008 (in Japanese). Vol. 9 No. 6 June
7 Hayato Minami Research Engineer, NTT Access Network Service Systems Laboratories. He joined NTT in Since moving to NTT Access Network Service Systems Laboratories in 2008, he has been engaged in the development of systems for optical wiring techniques for MDUs. Kazutoshi Takamizawa Senior Research Engineer, Supervisor, NTT Access Network Service Systems Laboratories. He joined NTT in Recently, he has been engaged in the development of optical access network systems. Kensei Shiraishi Research Engineer, NTT Access Network Service Systems Laboratories. He joined NTT in Recently, he has been wiring techniques for MDUs and optical fiber drop cables. Tetsuhiro Numata Senior Research Engineer, Supervisor, NTT Access Network Service Systems Laboratories. He joined NTT in Recently, he has been wiring techniques for MDUs. Tadashi Sasaki Research Engineer, NTT Access Network Service Systems Laboratories. He joined NTT in Recently, he has been wiring techniques for MDUs. Osamu Inoue Manager, NTT EAST-KANAGAWA CORPO- RATION. He joined NTT in Recently, he has been wiring techniques for MDUs and optical fiber drop cables. The work described in this article was performed while he was a Senior Research Engineer in NTT Access Network Service Systems Laboratories. He moved to NTT EAST- KANAGAWA CORPORATION in July NTT Technical Review
Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER
Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) Abstract Fiber-to-the-Premises (FTTP) networks increasingly
FTTx Optical Fiber Cable for Easy Mid-Span Access ( EZremove )
INFORMATION & COMMUNICATIONS FTTx Optical Fiber Cable for Easy Mid-Span Access ( EZremove ) Toshio AKIYOSHI*, Keisuke OKADA, Hiroki ISHIKAWA, Toshiaki TAKAHASHI, Kenji ISOGAI, Kiyotaka NISHIOKA and Akio
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
InstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Multi-Dwelling Unit Fiber Deployment
Multi-Dwelling Unit Deployment Billions of dollars are spent annually delivering high speed fiber networks to Multi-Dwelling Units (MDUs) apartments, condos, and student-housing across North America. Service
10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable
10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable StarTech ID: IES101002SFP The IES101002SFP 10-port Ethernet switch delivers flexibility and control of your network by
ASKING FOR ASSISTANCE
ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM - 5:00 PM Monday - Friday, Pacific Time Write To: Gefen LLC c/o Customer
Service Guide. Gateway M275
Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying
Cisco Unmanaged Rackmount Switches
Quick Start Guide Cisco Small Business Cisco Unmanaged Rackmount Switches Package Contents Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch Rackmount
BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors
C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution
Installation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
Relay mounting systems
Page 1 Issued July 1998 Changed since April 1997 Data subject to change without notice RL COMBIFLEX RE 500 (SE 94832) (SE 970140) (SE 950216) Features Suitable for standard 19 rack, flush, semiflush, projection
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
About the BitStorm 6051 POTS Splitter
BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service
UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M5 13 8 To mount outer member to rack
UPDATEUPDATEUPDATE Converting the tower chassis to a rack-mount chassis Rail overview Converting your Server to Rack-Mount The rail kit includes the following: Two rail units Five packages of screws (labeled
Changing the SIM in a BANDIT Product s GSM Card
encor! enetworks TM Version A.2, January 2013 2013 Encore Networks, Inc. All rights reserved. Changing the SIM in a BANDIT Product s GSM Card Wireless connections use radiofrequencies (RFs) through airwaves
EuroSynth FracRak Comparisons
A summation of the major differences between the EuroSynth and FracRak systems. This documents attempts to cover the major differences between these 2 popular `mini modular systems and the pros and cons
EZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-54 Case IH CVX 1135 CVX 1145 CVX 1155 CVX 1170 CVX 1190 CVX 1195 CVX 135 CVX 145 CVX 155 CVX 175 CVX 195 New Holland TVT
4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
TECHNICAL INFORMATION
TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier
IP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
SECTION 25110 TELECOMMUNICATION ROOMS
PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication
EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions
EXPLORE 4-Leg Teaming Table with Screen Share Monitor Display Requirements: your flat panel display must confirm to the following requirements. y With the stand removed, the monitor must not exceed 40
Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer
Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer This booklet describes how to install the video input and TV tuner cards in a compact Macintosh computer
Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug
Electrical Connection When installed the range must be electrically grounded in accordance with local codes or; in the absence of local codes with the National Electrical Code ANSI/NFPA 70, latest edition.
FiberGuide Fiber Management Systems. 4th Edition
FiberGuide Fiber Management Systems 4th Edition Table of Contents Introduction Introduction...1 A Variety of Solutions...2 Innovative Products...3 Features and Benefits... 4 Applications Combining System
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
New Wiring Technology for Cost-effective Construction of FTTH Networks Using Free Branch Cable
INFORMATION & COMMUNICATIONS New Wiring Technology for Cost-effective Construction of FTTH Networks Using Free Branch Cable Kenichiro OHTSUKA*, Hiroshi MIYANO, Katsuyuki AIHARA, Masahiro HAMADA, Keiju
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
50 TO 60 INSTALLATION INSTRUCTIONS v1.0
50 TO 60 INSTALLATION INSTRUCTIONS v1.0 PLEASE READ Thank you for purchasing The TV Shield. Please read the following, before starting the installation process. UYou will need to unscrew the ten (10) black
Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer
5000020G Warning Before Installation English Power off the Network Camera as soon as smoke or unusual odors are detected. Do not place the Network Camera on unsteady surfaces. Do not insert sharp or tiny
Mounting Instructions for SP4 Power Modules
Mounting Instructions for SP4 Power Modules Pierre-Laurent Doumergue R&D Engineer Microsemi Power Module Products 26 rue de Campilleau 33 520 Bruges, France Introduction: This application note gives the
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
Tyan Computer. Transport PX22. Service Engineer s Manual
Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,
Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A
Installation Guide Wyse D Class 4-GB RAM Upgrade Option Kit Products: D90D7, D90DW Issue: 121312 PN: 883884-35L Rev. A Copyright Notices 2012, Wyse Technology Inc. All rights reserved. This manual and
DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS
DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS TheRTAStore.com STEP 1: CLEAR A WORK SPACE Place your RTA cabinet panels on a smooth, scratch resistant surface in a large, open area. (Some people like to
Raritan LCD KVM Console (T1700/T1900)
Raritan LCD KVM Console (T1700/T1900) Quick Installation and Setup Guide Congratulations on your purchase of Raritan LCD KVM Console, one of the best-known LCD KVM drawers in the current market. The Raritan
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
AM/FM ANTENNA RELOCATION KIT
-J0 REV. 008-09-0 AM/FM ANTENNA RELOCATION KIT GENERAL Kit Number 766-09 Models This kit is used to relocate a fender-mounted AM/FM antenna to a Detachable Tour-Pak on specific model motorcycles. For model
Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO.
Spec Sheet CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO.COM Overview................................................ 3 Rack Certifications
Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers
CABINETS: ENCLOSED THERMAL MOUNTING MANAGEMENT SYSTEMS WHITE PAPER Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers 800-834-4969 [email protected] www.chatsworth.com All products
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
Wren Kitchens Installation Tips... 3. Carefully check your kitchen delivery... 4. Measuring out and marking up... 5. Fitting the base cabinets...
tra 1 Index Wren Kitchens Installation Tips... 3 Carefully check your kitchen delivery... 4 Measuring out and marking up... 5 Fitting the base cabinets... 6 Fitting the corner cabinets... 7 The 972mm or
Installation. Basic Rack Power Distribution Unit for Blade Servers
Installation Basic Rack Power Distribution Unit for Blade Servers Contents Preliminary Information...................1 Features............................. 1 Receiving inspection................... 1
Rack Installation Instructions
Rack Installation Instructions Second Edition (June 2014) 2014 Contents Chapter 1. Safety information..... 1 Chapter 2. Rack kit parts inentory... 3 Chapter 3. Rack installation...... 5 Identifying the
Electrical TV Lift mechanism TS750. Parts included with your TV Lift
Parts included with your TV Lift Lift unit ( #1 ) Power supply ( #2 ) R.F. Module ( #3 ) Rocker switch ( #4 ) Remote Control (not shown) Plasma screen brackets ( #6a ) Lift Brackets ( #6b ) Lid Lifter
Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)
Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section
Raritan LCD KVM Console (T1700/T1900)
QS Rule Raritan LCD KVM Console (T1700/T1900) Quick Setup Guide Thank you for your purchase of the LCD KVM Console, one of the best-known LCD KVM drawers in the current market. The Raritan LCD KVM Console
H45 LED - Direct and indirect pendant
RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
Field Installable Optical Connector for Cables
Field Installable Optical Connector for Cables Daigo Saito 1, Kazuhiro Takizawa 1, Kazuya Ogata 1, and Tan Khee Yen Serin 2 With the rapid expansion of fiber to the home (FTTH) in Japan, mechanical splices
ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6
050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY
42U/45U 28" Wide Rack Installation & Service Guide
42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part
Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs)
Fibre Optic Wiring Guide for Multiple Dwelling Units (MDUs) Greenfield/Brownfield Renovations Table of Contents Future-Proof your Building... 1 MTS Fibre Optics Installation Guidelines... 2 MTS Fibre Optics
I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06
EN I. Introduction 02 Specifications 02 Accessories 02 Features 03 II. Installation Instructions 06 1. Installation of the motherboard 06 2. Installation of the power 07 supply 3. Installation of external
Full_IG.book Page 1 Monday, January 9, 2012 6:11 PM. ProSafe 24 Port Gigabit Switch Installation Guide
Full_IG.book Page 1 Monday, January 9, 2012 6:11 PM ProSafe 24 Port Gigabit Switch Installation Guide Full_IG.book Page 2 Monday, January 9, 2012 6:11 PM 2011 NETGEAR, Inc. All rights reserved. No part
4 Small Cables Sealing Kit: Wrap Style
4 Small Cables Sealing Kit: Wrap Style I N S T A L L A T I O N I N S T R U C T I O N Gel Wrap Kit For Sealing up to 4 Small Cables in FOSC 450 & FOSC 600 Closures Max. Combined Diameter Closure Port of
DCF Optimized Rack System
Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that
HDTV. Amplified Indoor Outdoor Antenna. indoor outdoor. 10 db Amplification. Paintable. Versatile TERRESTRIAL VHF UHF
Amplified Indoor Outdoor Antenna VHF UHF 10 db Amplification fixed 10 db amplification for improved reception of weak signals Paintable customize your antenna color to match your interior or exterior décor
Pretium Connector Housings
Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center
Removing chips is a method for producing plastic threads of small diameters and high batches, which cause frequent failures of thread punches.
Plastic Threads Technical University of Gabrovo Yordanka Atanasova Threads in plastic products can be produced in three ways: a) by direct moulding with thread punch or die; b) by placing a threaded metal
Wideband Optical Splitters FOS Series
Wideband Optical Splitters FOS Series Guide to Installation and Operation M949-9100-103 13 Mar 2014 Miranda Technologies 3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 2C6 Tel. 514-333-1772 Fax.
Installation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
EZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-21 Case IH Puma 165 Puma 180 Puma 195 Puma 210 New Holland T7030 T7040 T7050 T7060 Revision A June 2007 Part Number 53345-21-EU2
1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.
Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847 673-5009 email@gaertnerscientific.
7109-C-244E-R1 Field Installation of HeNe Laser in B, C, and D-Type Auto Gain Ellipsometers GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET
Be sure to read this installation manual thoroughly prior to installation. If installation methods or non-standard parts not specified in this installation manual are used, accidents or injury may result.
POWER LOCK KIT GENERAL INSTALLATION -J04427 REV. 2007-12-04. Kit Number. Models. Additional Parts Required. Kit Contents
-J0 REV. 00--0 POWER LOCK KIT GENERAL Kit Number -0, 0-0 Models For model fitment information, please see the P&A Retail Catalog or the Parts and Accessories section of www.harleydavidson.com (English
Switchboard system. NorLine 800
Switchboard system NorLine 800 NorLine 800 SWITCHBOARD SYSTEM 2 NorLine 800 Switchboard system Table of contents Subject Page Table of contents 2 Overview 2-3 NorLine 800 technical specifications 4 Structural
Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009
Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide Version 8.2 March 2009 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology,
Home Signal Distribution Kit for Satellite TV Plus SIRIUS
SR-101C SIRIUS/DBS Signal Combiner System SR-2261 Combiner-Outdoor Made in China DBS IN SIRIUS IN SR-101C SIRIUS/DBS Signal Combiner System SR-2251 Splitter-Indoor Made in China DC IN DBS OUT SIRIUS OUT
6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU
6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety
installation guide ACTIV-1
installation guide ACTIV- Base foot. Leg x columns - right & left Motor unit. Work surface supporting bracket (Cantilever) x Control. box Base foot x Handset 4. Phase Motor unit Materials and Tools Hardware
+1 716.242.8500 Buffalo, New York Garland, Texas www.garlandtechnology.com
Effective January 1, 2013 contains. Copyright 2013 Garland Technology LLC. ll Rights Reserved. Oxxxxx Series Passive Fiber Tap Garland Technology Passive Fiber Chassis Options Single Fiber TP Chassis Oxxxx1
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Chapter 9. Bonding and Grounding
Chapter 9 Bonding and Grounding Objectives Describe why the cable should be bonded Describe bonding and grounding procedures Define Bonding and Grounding Explain Safety Benefits and intent of bonding and
Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers
SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the
Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: 122211 PN: 883884-32L Rev.
Installation Guide Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit Products: Z90DW, Z90SW, Z90D7, Z90S7 Issue: 122211 PN: 883884-32L Rev. A Copyright Notices 2011, Wyse Technology Inc. All rights reserved.
AU-110 racking guide NBXPN: 023
AU-110 racking guide NBXPN: 023 1. Overview NIMBOXX AU-110 Rack Installation This guide provides setup instructions for installing your NIMBOXX AU-110 in a rack. Following these steps in the order given
Rack Installation Instructions
Rack Installation Instructions Guidelines This publication provides information about how to install your server into a standard rack cabinet using the rail kit shipped with your server. If you no longer
HP 16/18-Port Cable Management Kit Installation Guide
HP 16/18-Port Cable Management Kit Installation Guide Abstract This document describes how to attach the HP 16 Port or 18 Port Cable Management Kit to an HP rack. The cable management bracket is designed
Quick Start Guide. Cisco Small Business. 300 Series Managed Switches
Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device
The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity
Optical LAN Solutions The Infrastructure of Tomorrow, Available Today Luca Rozzoni RCDD Business Line Manager TE Connectivity Key Terms PON - Passive Optical Network - (Carrier) Between Central Office
BUILD A TABLETOP LOOM
BUILD A TABLETOP LOOM From 1" x 2" stock (actual 3/4" x 1"1/2) cut: 4 pieces 15" long 4 pieces 5"1/2 long Use the above to make 2 frames for the front and back of the loom. From 1" x 4" stock (actual 3/4"
LED Cable Connector Module Cable Punch and Termination Tool Order No. 62100-6700
FEATURES LED Cable Connector Module Cable Punch and Termination Tool Order No. 62100-6700 Same tool used for punching cable and terminating connector Handheld tool intended for field installation or repairs
Huwilift DUO, Huwilift DUO Forte Seite 4 3. Huwilift MAXI. Huwilift MAXI UP. Huwilift Senso, Huwilift E-Senso Page 4 17
INDEX Lifters Huwilift DUO, Huwilift DUO Forte Seite 4 3 Classic solution for lift-up flaps. Huwilift MAXI Page 4 7 Quickly installed for a gentle lift. Huwilift MAXI UP Page 4 13 Lifts and lowers chest
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
Setting Up and Testing the MAX Hardware
Page 1 of 12 Setting Up and Testing the MAX Hardware This chapter covers these topics: Planning the hardware installation Inserting an expansion card Setting up the hardware Connecting to input power Connecting
EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique
EXTeR US G L A S S - With patented design, able to join technology and quality of materials with a charming shape. Unique thanks to its outstanding loading capability with 150 kg maximum weight and height
BIX Termination Blocks
Characteristics One piece unit that passes the connection through Unit is reversed after cable connection for the cross-connect field Mounting Frames are available 250-pair, in 50-pair, 300-pair and 900-pair
INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
INSTLLTION INSTRUTIONS 24" (61.0 M) LTRI SINGL N OUL UILT-IN OVN Table of ontents UILT-IN OVN SFTY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements... 2 lectrical Requirements...
Panel Track Installation Guide
Panel Track Installation Guide We make it easy! BTG 493361 EN_0510 Before starting Your new Blinds To Go panel track is custom made to your specifications from the finest materials available. To ensure
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an