Eaton Automatic Transfer Switches



Similar documents
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

How To Test A Power Switch On A Power Supply

Low Voltage Fuses For Motor Protection

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Arc Flash Mitigation & Selective Co-ordination

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Secondary Unit Substations

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Data Bulletin. Circuit Breaker Characteristic Trip Curves and Coordination Class 0600 TRIP CURVES AND COORDINATION CIRCUIT BREAKER TRIP CURVES

Bypass transfer switch mechanisms

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Alternate Methods to Short Circuit Breaker Coordination

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

Continuous Power... Continuous Protection

Low Voltage Switchgear

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Grounding of AC generators and switching the neutral in emergency and standby power systems

The following components are common to most cubicles; this example is an ABB HK cubicle.

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Circuit Breakers. Next Generation of Protection Capabilities

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

415V DISTRIBUTION FOR GREEN DATA CENTERS

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Safety By Design. Strategies for Electrical Contractors

Application of Four-Pole Circuit Breakers within Data Centers

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Medium Voltage Motor Control Assemblies

Contractors Guide Central Inverter System Installation

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Engineering Series Ratings: Is It Practical?

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

8146/5 Series Breaker Panelboards

Low Voltage Products. Switches Automatic Transfer Switches

ATS - Automatic Changeover

Primary and Secondary Electrical Distribution Systems

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

690 V is a good alternative in the process industry

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Integrated Power Systems for Data Centers

Atlanta Chapter IEEE Industry Applications Society

The Application of Circuit Breakers to Reduce Downtime in Datacentres

MCC Ratings. Voltage Rating

ELECTRICAL: AUTOMATIC TRANSFER SWITCHES

Reverse-feed applications for circuit breakers

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

How To Choose A Transformer

White paper. ABB solutions for switching and protection of low speed wind turbines

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

ASCO SERIES 185 Power Transfer Switches

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

High Efficiency Motor Protection. Industry White Paper

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

415V DISTRIBUTION FOR GREEN DATA CENTERS

Vilter motor starter solutions The NEW industry standard in motor starter packages

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

SWITCHGEAR. EGP Switchgear

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

IRRIGATION PUMPING Table of Contents - Section 900

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

The complete range of consumer switchboards and switchgear

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

MAJORSINE Power Inverter

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Owner's Manual. Automatic Transfer Switch. This manual should remain with the unit.

Fault Characteristics in Electrical Equipment

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Sentron Series Circuit Breakers

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

A Deeper Look into Switchgear and Switchboards

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Electrical Grounding. Appendix C

Extend the Life of Existing Switchgear

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Mission Critical Data Center Systems

Industrial Ethernet How to Keep Your Network Up and Running A Beginner s Guide to Redundancy Standards

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

Transcription:

This is a photographic template your photograph should fit precisely within this rectangle. Eaton Automatic Transfer Switches Jody Grabowski Eaton ATS Product Line Sales Engineer February 1st, 2011 2008 Eaton Corporation. All rights reserved.

Overview Understanding Transfer Switch Withstand Ratings Switching the Neutral New Bypass Isolation Contactor Technology Questions 2 2

This is a photographic template your photograph should fit precisely within this rectangle. Transfer Switch Withstand Ratings 2008 Eaton Corporation. All rights reserved.

UL 1008 Withstand Ratings Any Breaker Any circuit breaker can be used upstream. Test Procedure Withstand - Current is applied for 3 cycles and the contacts must remain closed. The contactor must remain functional. Close-on Contacts must close on the selected fault current level and remain closed for 3 cycles. ATS must remain functional. Specific Breaker Only circuit breakers listed as specific breakers on the ATS UL label may be applied upstream. Test Procedure Manufacturer provides UL Rep with the list of desired specific breakers. The ATS is tested with the slowest acting breaker upstream for withstand and close on. Short Time An ATS must have a short time rating to be applied downstream from a breaker with a short time rating. Withstand - Current is applied for > 3 cycles (manufacturer determined) and the contacts must remain closed. The contactor must remain functional. Close-on Contacts must close on the selected fault current level and remain closed for same number of cycles. The contactor must remain functional. Temperature Rise Test 4 4

Transfer Switch Equipment and UL1008 In 1997: UL added 41.20, effective September 18, 1997 41.20 A transfer switch tested for three cycles shall be marked, When protected by a circuit breaker without an adjustable short-time response only or by fuses 5 5

Transfer Switch Equipment and UL1008 WHY? Unfortunately the UL1008 3-cycle test does NOT require verification of contact viability. The fact that the upstream breaker probably trips, and causes an power failure to the ATS logic, hopefully causes a subsequent transfer to the backup source. If you do NOT verify contact viability in a true shorttime situation you might get caught with an ATS that acts like a fuse, an upstream breaker that doesn t trip, and no power failure to the ATS. Hence a loss of power to the load! 6 6

Withstand / Close-on Ratings Critical Power Switches Have 3 Cycle Any Breaker Ratings 50 600 UL Listing Valid Only if Used with the Circuit Breakers Indicated on Manufacturers Label. Listing must Include Numerous Breakers for Application Flexibility. 7 7

Specific Breaker Lists Each manufacturer has a unique Specific Breaker List Includes Eaton s and Competitors Breakers Includes current and vintage breakers 8 8

3 Cycle vs. 30 Cycle X F1 ATS protected by an PCB with an adjustable trip unit (i.e. LS, LSG) ATS has as Short Time Rating Downstream PCB selectively coordinated with upstream PCB Downstream Breaker clears fault (short time setting up to 0.5s) ATS stays on Utility source (no loss of power) ATS must maintain integrity as the ATS does not transfer from Utility source, reason for temp test after 30 cycle short time test in UL1008 9 9

Short Time Definition in UL1008 Short-time current rating is the maximum amount of fault current a switch can withstand at a specified voltage for a given amount of time and remain functional. 10 10

Transfer Switch Equipment and UL1008 In 2002 UL added Paragraph 36A Short-Time Current Rating Test (Optional), and marking 41.20.1. What is different? Paragraph 36A.1 g) requires that a Temperature Rise test be performed AFTER the withstand test. Paragraph 36A.1 h) requires that the dielectric withstand test be rerun. 11 11

Transfer Switch Equipment and UL1008 If you will be using a breaker with a Short Time Trip element upstream from the ATS, then UL indicates you MUST use a transfer Switch with a UL1008 Short Time Rating. 12 12

Selective Coordination & NFPA 70 The National Electrical Code (NEC) NEC VERSIONS Article Title 1993 1996 1999 2002 2005 2008 100 Definitions 517 Healthcare Facilities 517.26 517.26 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Wheel Chair Lifts, and Stairway Chair Lifts 620.51(a) 620.62 620.62 620.62 620.62 620.62 700 Emergency Systems 700.27 700.27 Exception 701 Legally Required Standby Systems 701.18 701.18 Exception 708 Critical Operations Power Systems (COPS) 708.54 13 13

Conclusion on Short Time Ratings Although the Short time test is optional, it is required for certain applications. If your ATS is not labeled with a short time rating as shown, it is a misapplication of the ATS if selectively coordinated between breakers set higher than 3 cycles. A 3 cycle ATS rating can only be protected by a breaker with an instantaneous trip. 14 14

This is a photographic template your photograph should fit precisely within this rectangle. Switching the Neutral 2008 Eaton Corporation. All rights reserved.

When to Switch the Neutral It is recommended to switch the neutral when working with a separately derived system. This is generally accomplished with a fully rated four pole switch or by utilizing a three pole switch with an overlapping neutral. Non-Separately Derived System - Those systems where only one bonding jumper between the neutral and ground exists. Separately Derived System Each power source has it s own reference to ground. 16 16

Methods to Address Separately Derived Systems 17 17

Reference White Paper 3 pole vs. 4 pole switching http://www.eaton.com/ecm/idcplg?idcservice=g ET_FILE&dID=223905 18 18

This is a photographic template your photograph should fit precisely within this rectangle. New Bypass Isolation Transfer Switch Technology 2008 Eaton Corporation. All rights reserved.

Eaton Contactor-Based Bypass Isolation Transfer Switch 100A 1200A 100% rated ATC-300, ATC-800 Delayed and Closed Transition Front Accessible No Load Break Transfer to Bypass Dual ATS Available Dual Draw-out or Fixed Bypass Nema 1, 3R (12 and 4X 2011) 20 20

Dual ATS Dual ATS functionality Both the ATS and the Bypass are controlled by the ATC controller 21 21

Bypass Isolation ATS Construction Top Interconnect Compartment Standard Front Access Field Reconfigurable Bypass Contactor Compartment ATS Contactor Compartment Separate Compartment Doors Bottom Interconnect Compartment 1200 Amp 3 Pole Open Transition 22 22

Eaton Bypass Contactor Withstand Ratings Withstand Rating (Any Breaker) KA @ 480v Withstand Rating (Specific Breaker) KA @ 480v Withstand Rating (Any Breaker) KA @ 600v Withstand Rating (Specific Breaker) KA @ 600v 100 30 50 30 50 200 30 50 30 50 400 30 50 42 65 600 50 65 42 65 800 50 65 42 65 1000 50 65 42 65 1200 50 65 42 65 23 23

Draw-Out ATS with Fixed Bypass 78 H X 30 W X 29 D Nema 1 90 H X 40 W X 29 D Nema 1 24 24

Terminal Connections Fixed Bypass Factory configured terminal location Top, Bottom, or combination of both. Must select at time of order. Top Connect Bottom Connect 25 25

Dual Draw-out (Optional) ATS and Bypass contactors are identical, thus interchangeable Both the ATS and Bypass are draw-out contactors Connection to Contactor Locked In Position Connected Isolated Position Connected Racked Out Disconnected Bypass ATS 90 H X 40 W X 29 D Nema 1 26 26

Connectable Bus Links (W/Dual Draw-out Option) 27 27

Safety Interlocks Isolated Locked In Door closed Five Sets of Interlocks Trip contactor if contactor is closed when racking out Trip contactor to neutral position upon racking unit in Prevent Opening ATS Compartment Door Prevents Opening Ratchet Slot Prevent ATS contactor testing until isolated 28 28

Questions? 29 29