4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System



Similar documents
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP

Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, and AXXRPFKSNSH Installation Guide

HP SATA/SAS hard drive and Solid State Drive installation

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Intel SC5100 Pedestal and Rack Server Chassis Subassembly Product Guide

Replacing the Gateway M320 Keyboard

Replacing the Gateway M675 Keyboard

Small form factor bay converter and hard drive installation

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Intel Server System P4000RP Family Service Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products

Upgrading and Servicing Guide

Hard Disk Drive (HDD)

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Tyan Computer. Transport PX22. Service Engineer s Manual

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

HP 22-in-1 Media Card Reader

Wall-Mounting your HP computer. User Guide

Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE

HP Optical Bay Hard Drive Bracket

HP ProLiant DL165 G7 Server. Installation Instructions

Front Panel Board Cable Replacement Instructions

Service Guide. Gateway M275

Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Intel Storage Server SSR212MC2/ SSR212MC2R User Guide

StorTrends 3400 Hardware Guide for Onsite Support

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Dell Inspiron 660s Owner s Manual

EasyNote TJ Series. Disassembly Manual

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

UPGRADING AND SERVICING GUIDE

Processor Cage Fans, Front and Rear Replacement Instructions

SERVICE GUIDE. Gateway Notebook

Inspiron 15. Service Manual Series

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

Memory Modules User Guide

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Intel Server System SC5650HCBRP Service Guide

Upgrading or Replacing a Host Interface Card in a Xanadu-230 Controller-Drive Tray

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Inspiron 13. Service Manual Series. Computer Model: Inspiron Regulatory Model: P57G Regulatory Type: P57G001

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

To view this information... Installing additional tape drives page 5 Replacing a tape drive with the same configuration

Intel Technical Advisory

3-4 SAS/SATA II HDD Canister Deluxe version

LSI MegaRAID SAS 8888ELP Host Bus Adapter installation

Internal USB port kit installation

Enclosure Management Cabling Guide for Intel C200 and C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

MAXDATA PLATINUM Blade Server. User s Manual

Changing the SIM in a BANDIT Product s GSM Card

Installing Your 960 or 980 Server into a Rackmount Cabinet

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Removable 2.5 SATA HDD Backup System

Intel RAID Expander Card RES3TV360 Hardware User's Guide. Intel Order Number: H

Intel Entry Server Chassis SC5275-E

HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide

What is the Fan Tray Assembly?

Power Supply Guide Version 1.0 for D-Show

Serial ATA to Serial ATA

Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3

How To Install A Power Supply (Uplast) With A Battery Pack

HP Integrity rx2660 Server Installation Guide

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

PS6500 Storage Arrays Rack Mount Instructions

TS500-E5. Configuration Guide

BladeRunner 4U Blade Server User Manual. December 2004 (Revision A)

Set Up Your MXI -Express x4 System

5800 Temperature Sensor Cable Assembly

Installing your upgrade processor

Intel RAID Controller Troubleshooting Guide

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Packard Bell Easy Repair 1. Packard Bell Easy Repair

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

Serial ATA PCI Quick Installation Guide

Hardware Manual. Versio. 2 RU Platform 7/10/

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

Accessing the printer system board

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Refer installation of power supplies to qualified service personnel.

Intel Server Chassis P4304XXSHCN/P4304XXSFCN/P4000XXSFDR

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

MCR1900 Media Converter 19-Slot Chassis

Rack installation instructions

Packard Bell Easy Repair

Contents. Installing the upgrade memory kit in the G450 and G430 Media Gateway May

Intel Server System SR1625UR Service Guide

Intel Server Board S5520HC, S5520HCT and S5500HCV Service Guide

Rack Installation Instructions

Intel Desktop Board D101GGC Specification Update

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

Removing memory and option cards

Transcription:

4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System Order Number: G23758-002 G23758-002 This document provides instructions for installing the following accessory kit: FUP4X35HSDK

Disclaimer Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright 2005-2011 Intel Corporation. All Rights Reserved. ii

Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See Intel Server Boards and Server Chassis Safety Information at http://www.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel- Serverplatinen und -Servergehäusen unter http://www.intel.com/support/motherboards/server/sb/cs-010770.htm. 重 要 安 全 指 导 在 执 行 任 何 指 令 之 前, 请 阅 读 本 文 件 中 的 所 有 注 意 事 项 及 安 全 声 明 并 参 阅 http://www.intel.com/support/motherboards/server/sb/cs-010770.htm 上 的 Intel Server Boards and Server Chassis Safety Information( Intel 服 务 器 主 板 与 服 务 器 机 箱 安 全 信 息 ) Consignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction.consultez Intel Server Boards and Server Chassis Safety Information rendez-vous sur le site http://www.intel.com/support/motherboards/server/sb/cs-010770.htm. Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en http://www.intel.com/support/motherboards/server/sb/cs-010770.htm. iii

Warnings and Cautions These warnings and cautions apply whenever you remove the access cover to access components inside the server. Only a technically qualified person should integrate and configure the server. WARNINGS The power button on the front panel DOES NOT turn off the AC power. To remove power from server, you must unplug the AC power cord from the wall outlet or the chassis. Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cords, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result. Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing should be done by technically qualified personnel. CAUTIONS ESD can damage disk drives, boards, and other parts. Perform all procedures in this document only at an ESD workstation. If one is not available, provide ESD protection by wearing an anti-static wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts. Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. Do not touch the connector contacts. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. For proper cooling and airflow, always install the access cover before turning on the server. Operating it without the cover in place can damage system parts. iv

Table of Contents Before You Begin...1 About the Drive Cage Kits... 1 Kit Contents lists... 2 Tools and Supplies Needed... 2 Intel Server Chassis P4000S family Installation...3 Remove the Chassis Cover... 3 Remove the Front Bezel Assembly... 4 4x3.5" Hot-Swap Drive Cage Installation... 5 4x3.5" Hot Swap Backplane Cable Connections... 7 Connect the following cables when installing a four-drive backplane (FUP4X35HSBP):7 Server Board/RAID Controller Connections... 7 Install Hot-Swap Hard Drives... 8 Replace Front Bezel Assembly for Hot-Swap Hard Drive... 9 Install the Chassis Cover... 11 Complete Setup... 11 v

List of Figures Figure 1. Removing the Chassis Cover... 3 Figure 2. Removing the Front Bezel Assembly... 4 Figure 3. Removing the EMI Shield... 5 Figure 4. Removing fixed HDD carrier tray... 5 Figure 5. Installing the EMI HDD shield under the hot-swap cage... 6 Figure 6.Installing the 4x3.5" Hot-Swap Hard Drive Cage... 6 Figure 7. 4x3.5" Hot Swap Backplane (FUP4X35HSBP) Cable Connections... 7 Figure 8. Removing the 2.5" HDD interface bracket from Carrier... 8 Figure 9. Installing the 3.5" HDD into the Carrier... 8 Figure 10. Reinstalling the Front Bezel Assembly for Hot-Swap... 9 Figure 11. Front View of the Front Bezel for Hot-Swap hard drive... 10 Figure 12. Installing the Chassis Cover... 11 vi

Before You Begin Before removing the access cover for any reason, you must observe the following safety guidelines: 1. Turn off any peripheral devices connected to the server. 2. Turn off the server by pressing the power button on the front of the chassis. 3. Unplug the AC power cord from the chassis or wall outlet. 4. Label and disconnect all peripheral cables connected to I/O connectors or ports on the back of the chassis. 5. Label and disconnect all telecommunication lines connected to I/O connectors or ports on the back of the chassis. 6. Provide electrostatic discharge (ESD) protection by wearing an anti-static wrist strap attached to a chassis ground any unpainted metal surface when handling components. About the Drive Cage Kits 4x3.5" hot-swap driver cage kits allow you to install up to 4 hot-swap hard drive solutions for the following Intel Server Chassis: Intel Server Chassis P4304XXSFCN Intel Server Chassis P4304XXSHCN NOTE Refer to your server board documentation to determine the SAS/SATA support provided for your server system. If you want to use your SAS/SATA drives for a RAID configuration, you may need to install a SAS/SATA RAID add-in card. Refer to your server board documentation and/or your SAS/SATA RAID card documentation for additional installation instructions and requirements. 1

Kit Contents lists The following tables provide a list of contents for 4x3.5" hot-swap drives cage kit. 4x3.5 hot-swap drive cage kit (FUP4X35HSDK) Item Quantity Drive cage assembly 1 SATA hot-swap Drive carriers 4 SAS/SATA cable assembly with ID label 4 I2C cable 1 SGPIO cable 1 EMI HDD Cover 1 This manual 1 Tools and Supplies Needed Phillips* (cross head) screwdriver (#2 bit) Anti-static wrist strap (recommended) Serial ATA (SATA) RAID card (dependent on installation) SAS RAID card (dependent on installation) 2

Intel Server Chassis P4000S family Installation NOTE This section applies only to the drive cage kit installations into: Intel Server Chassis P4304XXSFCN Intel Server Chassis P4304XXSHCN Remove the Chassis Cover When your chassis is upright (in a tower/pedestal position) and you are facing the rear of it, the access cover is on the right side. If your chassis is in a rack-mount configuration, the right side is already on the top. To remove the Chassis cover: 1. Observe the safety and ESD precautions at the beginning of this manual. 2. Turn off all peripheral devices connected to the server. Turn off the server. 3. Disconnect the AC power cord. 4. Remove the screws (see letter "A"). 5. Slide the top cover back (see letter "B") and lift the cover outward to remove it. Figure 1. Removing the Chassis Cover 3

Remove the Front Bezel Assembly NOTE For a rack configuration or chassis on its side, position the chassis hanging over the edge of a table or workbench before removing the bezel. To remove the front bezel assembly: 1. Observe the safety and ESD precautions at the beginning of this manual. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see Remove the Chassis Cover. 4. Release the two plastic tabs on the left side of the bezel assembly to disengage the tabs, and rotate the bezel assembly (see letter A ) no more than 40 degrees outward. 5. At a 40-degree angle, push the bezel assembly away from the chassis (see letter B ). 6. If the bezel assembly does not immediately disconnect from the chassis, tap the left-hand side of the bezel assembly to disengage the bezel hooks on the right-hand side of the chassis. CAUTION Do not rotate the bezel assembly more than 40 degrees or you will damage the bezel hooks on the right-hand side of the bezel assembly. Figure 2. Removing the Front Bezel Assembly 4

4x3.5" Hot-Swap Drive Cage Installation This section reviews the steps required to install the following upgrades: 4x3.5 Hot-Swap Drive Cage Kit (FUP4X35HSDK) NOTE If hard drives are installed in the existing fixed drive tray, disconnect the power and data cables to each drive. 1. Lift the EMI shield (see letter A ) and move EMI shield outward from the chassis (see letter B ). 2. Pull out all the fixed HDD carrier trays. Figure 3. Removing the EMI Shield Figure 4. Removing fixed HDD carrier tray 3. Install the hot-swap EMI HDD shield under the hot-swap cage. 5

a) Fit the edges of the EMI Shield against the sides of the chassis (see letter A ). b) While pressing the EMI Shield, slide the EMI Shield downwards until the latches on the EMI Shield are engaged with the chassis (see letter B ). Figure 5. Installing the EMI HDD shield under the hot-swap cage 4. Install the 4x3.5" Hot-Swap Hard Drive Cage. a) Slide the 4x3.5" Hot-Swap Drive Cage into the slot (see letter A ). b) Secure the Hard Drive Cage with the Screw (see letter B ). Figure 6.Installing the 4x3.5" Hot-Swap Hard Drive Cage 6

4x3.5" Hot Swap Backplane Cable Connections Connect the following cables when installing a four-drive backplane (FUP4X35HSBP): 1. Connect data cables (letter A ). 2. Connect an I2C_IN cable (letter B` ). 3. Connect an SGPIO cable (letter C ) 4. Connect power cable (letter D ) Figure 7. 4x3.5" Hot Swap Backplane (FUP4X35HSBP) Cable Connections Server Board/RAID Controller Connections Refer to the documentation that came with your server board and/or RAID controller for instructions on connecting backplane cables to the server board or controller. WARNING It is critical that you connect the SAS/SATA data cables correctly from the SAS/SATA backplane to your server board or RAID controller. Failure to do so may result in data loss. 7

Install Hot-Swap Hard Drives NOTE The 3.5" hard disk drive can be a SSD or SAS and SATA. Refer to your server board or system documentation to determine SSD/SAS/SATA support for your server system. 1. Remove the four screws securing the 2.5" HDD interface bracket and remove the 2.5" HDD interface bracket.. Figure 8. Removing the 2.5" HDD interface bracket from Carrier 2. Install the 3.5" hard disk drive using the same four screws as shown. Make sure the connector end of the drive matches the backplane connector. Figure 9. Installing the 3.5" HDD into the Carrier 8

Replace Front Bezel Assembly for Hot-Swap Hard Drive 1. Fit the right edge of the bezel assembly against the right side of the chassis. 2. Engage the plastic bezel hooks (see letter A ) into the raised metal slots at the chassis edge. 3. Rotate the bezel assembly toward the chassis. 4. Latch the two plastic tabs (see letter B ) on the left side of the bezel assembly to the chassis. CAUTION Do not attach the bezel assembly to the chassis at more than a 40-degree angle or you will damage the bezel hooks on the right side of the bezel assembly. Figure 10. Reinstalling the Front Bezel Assembly for Hot-Swap 9

Figure 11. Front View of the Front Bezel for Hot-Swap hard drive 10

Install the Chassis Cover 1. Slide the chassis cover on the chassis (see letter A ). 2. Latch the cover securely to the chassis. 3. Secure the chassis cover with the screws (see letter B ). Figure 12. Installing the Chassis Cover CAUTION This chassis must be operated with the access cover installed to ensure proper cooling. Complete Setup 1. Reconnect all peripheral devices and the AC power 2. Power up the server 11