RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH



Similar documents
AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Background Information

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Expectations for GC-MS Lab

Pesticide Analysis by Mass Spectrometry

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Application of Structure-Based LC/MS Database Management for Forensic Analysis

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

WATERS QUANTITATIVE ANALYSIS solutions

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Alignment and Preprocessing for Data Analysis

Analysis of Vegetable Oils by High Performance Liquid Chromatography

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Appendix 5 Overview of requirements in English

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

A Streamlined Workflow for Untargeted Metabolomics

Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

How To Analyze Pesticide Levels In Lemon Oil

AMD Analysis & Technology AG

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Micromass LCT User s Guide

Storage Conditions of Sausages

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Setting up a Quantitative Analysis MS ChemStation

Analyzing Small Molecules by EI and GC-MS. July 2014

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

How To Use Gc-Ms

MassLynx 4.1 Getting Started Guide

A Study on the Variability of Fresh Diesel from Service Station in Kota Bharu Using GC-MS and PCA

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

MEDICINAL CHEMISTRY APPLICATIONS BOOK

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Chemical Analysis of Chardonnay Wines: Identification and Analysis of Important Aroma Compounds

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Tuning & Mass Calibration

Fractional Distillation and Gas Chromatography

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Chemical Profiling and Differential Analysis of Whiskies Using Orbitrap GC-MS

Robert Birdsall, Eoin Cosgrave, Henry Shion, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Waters Core Chromatography Training (2 Days)

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

SCION SQ Series GC-MS

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

23 The Thermal Conductivity Detector

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

ProteinPilot Report for ProteinPilot Software

Mass Frontier 7.0 Quick Start Guide

Tutorial 9: SWATH data analysis in Skyline

ApplicationNOTE Introduction

Mass and Resolution Calibration for New Triple-Stage Quadrupole Mass Spectrometers. Rob Grothe Thermo Fisher Scientific, San Jose, CA

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna

How To Use An Acquity Qda Detector

O2PLS for improved analysis and visualization of complex data

Research-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Transcription:

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH Cristiana C. Leandro 1, Peter Hancock 1, Christian Soulier 2, Françoise Aime 2 1 Waters Corporation, Manchester, UK. 2 Argeville S.A., Domaine d Argeville, Mougins, France. AIM To provide a solution for the identification of potential markers of essential oils for the characterization of fragrances, to aid in quality control and authentication within the flavor and fragrance market. INTRODUCTION The flavor, fragrance, and aroma chemical market is said to be worth around $15 billion worldwide, with the essential oils market seeing significant growth backed largely by the increasing preference among consumers for more natural products. allows a good statistical separation and facilitates the identification of differences or similarities between groups. The following method describes essential oil characterization for a range of samples from the citrus family using a GC-TOF-MS solution complete with chemometric data analysis. Examples of essential oil separation, marker identification, interand intra-class differentiation will be illustrated as well as database building and fragrance characterization. As commodities in the fragrance and flavor market are generally high value items, the ability to characterize and compare raw materials, blends, and final goods has important financial implications. As prices of natural products fluctuate widely depending on the raw material, determining factors such as country of origin, climate, batch, concentration, extraction method, and shelf life become paramount for quality control and to prevent product counterfeiting. With reports of 5 to 7 of world trade being counterfeit products, amounting to a mammoth $5 billion annually, validation of factors in natural products such as essential oils become even more vital. Currently identification and characterization of fragrances is carried out manually, a very time-consuming process that can take a trained analytical chemist many hours, with a high risk of human error. By implementing a GC-ToF exact mass-ms solution, a powerful; information rich data set can be generated. Automated, chemometrics based software, using a statistical interpretation of patterns in multivariate data can be used for further analysis. This results in a faster and more precise assessment of composition. The advantage of using a chemometrics with GC-TOF-MS approach is the production of a unique fingerprint for each essential oil. This Four types of essential oils from the citrus family. EXPERIMENTAL Samples Four types of essential oils from the citrus family were studied (lemon, mandarin, orange and bergamot). The essential oils analyzed are listed in Table 1. The samples were diluted 1:1 in ethanol prior to analysis by GCT Premier.

Essential oils Origin MS conditions 1 2 3 4 5 6 7 8 Argentina Argentina Spain MS system: Waters GCT Premier TM Ionisation mode: Electron ionisation (EI +) Electron energy: 7 ev Source temperature: 2 C Trap current: 2 µa Interface temp.: 28 C Detector voltage: 285 V Acquisition range: m/z 5-5 Acquisition time:.19 s with.1 s delay (2.5 spectra/s) 9 1 Mandarin Yellow 11 Mandarin Yellow 12 13 14 15 16 17 18 GCT Premier Mass Spectrometer 19 South Africa 2 21 22 23 bitter Florida Florida Exact mass spectra were obtained using a single-point lock mass (perfluorotributylamine, m/z = 218.9856) infused into the source continuously during the run. The instrument was tuned so that resolution was greater than 7 FWHM (Full Width Half Maximum). 24 pera Brazil 25 Brazil Table 1. List of the pure essential oils. GC conditions GC system: Agilent 689N Column: Restek Rtx -5 ms, 3 m x.25 mm.25 µm Flow rate: 1. ml/min Helium constant flow Injection method: Split (split ratio of 1:1), 1 µl Temperature ramp: 6 to 18 C at 7.5 C/min and to 25 C at 5 C/min (hold for 1.6 min) Total run time: 2 min Acquisition and Processing Methods The data were acquired using Waters MassLynx TM Software v. 4.1 and processed using MarkerLynx TM and ChromaLynx TM Application Managers. n MarkerLynx is used for comprehensive data processing for chemometric applications, including multivariate statistical analysis and visualization. n ChromaLynx facilitates rapid detection, identification and semi quantitative determination of components in complex matrices.

RESULTS AND DISCUSSION Figure 1 shows that differences between citrus essential oils are not easily discerned and a manual chromatogram-by-chromatogram inspection is very labor-intensive. MarkerLynx automates this process by rapidly characterizing essential oils, based on a PCA data set and will generate a list consisting of t R - m/z pairs ranked in order of statistical significance. Mandarin 1 1, 6. 8. 1. 12. 14. 16. Mandarin, 6. 8. 1. 12. 14. 16. Figure 2. Scores plot obtained from MarkerLynx, illustrating group similarities between 25 essential oils. 1 1 1, 6. 8. 1. 12. 14. 16., 6. 8. 1. 12. 14. 16., Time 6. 8. 1. 12. 14. 16. Figure 1. Total ion chromatograms of five citrus essential oils obtained using GC-TOF-MS. The results show that the oils can be successfully separated. However, in order to determine the reasons for this differentiation, closer inspection of these results are required. Figure 3 shows one of the t R - m/z pairs that contributed most significantly to the separation of lemon from the rest of the oils. This trend plot showing sample number versus significance of marker to class, illustrates a potential marker for lemon oils. Rapid inter-class citrus oil differentiation Figure 2 illustrates the MarkerLynx scores plot after processing 25 essential oils. The results show that the three types of mandarin oils are statistically similar, while divergent from orange, lemon and bergamot. The high analytical reproducibility of the system is demonstrated through the tight sample clustering of each class of oil. Figure 3. Trend plot of the t R - m/z pair 12.89-93.7, across 25 essential oils.

Identification of potential essential oil markers After automated processing of the data sets using ChromaLynx, the potential marker shown in Figure 4 was identified by library searching and exact mass. The marker was identified as b-pinene with an exact mass of 136.1256,.4 mda from the calculated mass of C 1 H 16. Same producer Quality 26 Age 27 Figure 5. Scores plot obtained from MarkerLynx illustrating group similarities between four Italian mandarin red oils. Additionally, a supplementary software package, SIMCA-P from Umetrics, can be used to search for further differences within each class. SIMCA-P identifies differences between two samples, using advanced statistical tools such as partial least squares discriminate analysis (PLSDA) and orthogonal partial least squares (OPLS), allowing researchers to visualize their data and extract more meaningful information from their experimental results. Figure 4. Identification of b-pinene in a lemon oil using ChromaLynx. If the potential marker does not exist in the library, exact mass will enable the elemental composition to be determined as a useful start point in establishing structural identification. Figure 6 shows enhanced differentiation between two of the lemon oils. The points above 8 significance (highlighted in red) were selected and used to create an additional list of potential markers, which can be imported back into MarkerLynx. After potential markers have been identified, MarkerLynx can be used to create a database of compounds to help search for markers in subsequent analyses. Rapid intra-class essential oil differentiation It is also possible to find similarities within each class of oil using multivariate analysis. These intra-class differences include country of origin, age, quality, etc. For example, Figure 5 illustrates the intra-class separation of mandarin red oils obtained using MarkerLynx. Differences between sample clusters relate to the year of harvest and quality of the olfactory citrus notes. Figure 6. Scatter plot of lemon oil no. 7 vs. lemon oil no. 9, obtained from an OPLS model using SIMCA-P.

Identifying essential oils within a fragrance ChromaLynx Compare offers complementary functionality that is able to evaluate multiple samples to identify either common or unique components between them. Figure 7 shows the comparison between a fragrance and one lemon oil. The results show unique components by retention time and mass (flagged with the dark triangles). The common components suggest that this variety of lemon oil is part of the composition of the fragrance analyzed. CONCLUSIONS As the prices of raw materials vary greatly and product counterfeiting is a rising problem, the GCT Premier with MarkerLynx and ChromaLynx Application Managers is the ideal solution for product authentication and quality control in the flavor and fragrance market. With an unmatched combination of capabilities, as well as high full scan sensitivity and rapid spectral acquisition rates, this total Water s solution is ideal for full characterization and profiling of components in a wide range of sample types. Using GC-exact mass TOF-MS on the GCT Premier enabled separation and identification of potential markers in essential oil samples from the citrus family. Figure 7. Comparison of a fragrance (top chromatogram) with one lemon oil (bottom chromatogram), using ChromaLynx Compare. MarkerLynx with a chemometric approach to the interpretation of data, allowed valuable detection and identification of potential markers in these essential oils. Inter- and intra-class differentiation between samples was also achieved using SIMCA-P software with multivariate PLS or OPLS statistical methods. ChromaLynx Compare is also a useful tool in the characterization of fragrances. It enables the comparison of unique (or common) components that have previously undergone automated library search for identification. The GCT Premier with MarkerLynx and ChromaLynx Application Managers enables powerful data acquisition and analysis capabilities for fragrance characterisation. Plus, the automation of manually intensive processes will result in increased productivity and efficiency within the lab. Waters is a registered trademark of Waters Corporation., GCT Premier, MassLynx, ChromaLynx, MarkerLynx, and the Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 28 Waters Corporation. Produced in the U.S.A. March 28 722563EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 1757 U.S.A. T: 1 58 478 2 F: 1 58 872 199 www.waters.com