Similar documents
Packaging: MOQ: NIT, NET, TIA and TIS 20 per pack TCP and TFP 10 per pack Packaging 100% recyclable. Technical Data:

IEC and British Standard Fuses

Photovoltaic System Overcurrent Protection

High Speed Fuses. High Speed Fuses

Solar Circuit Protection Application Guide. Complete and reliable solar circuit protection

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Solar circuit protection application guide. Complete and reliable solar circuit protection

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

British BS 88 Fuses. Introduction

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

A project to optimise quality and energy efficiency must include metering

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Preset Counter signo 721

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

SOURIAU s discrete wire sealing

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Fuse Selection Method Module 2. Date of the presentation

R.C.C.B. s two-pole LEXIC

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Power Supplies 3. SDN-P DIN Rail Series

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Mini USB and USB 2.0-IP67 Connector System

CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61

BETA Protecting SITOR Semiconductor Fuses

4 Posiflow Proportional Solenoid Valves

3K Load-Break Switches The Program for Safety and Performance. sentric

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

DS 600. A contact free flux gate based current measurement sensor 600A rms

UMEC International Corporation

Thermal-Magnetic Circuit Breaker M1-..

3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series

3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series

Problem / Solution. The problem:

Vario-Series Accessories

handbook, 2 columns handbook, halfpage 085 CS


KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Solid State Timers Type F

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC / Class Y1, 500 V AC

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

CCM05 SD, MMC & minisd

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

Z-TRAUQ INC. Tel.: (450) Fax: (450)

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Technical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment

Copper and Aluminum busbars

Wood pellet and biomass system ceramic igniter

TC50 High Precision Power Thin Film chip resistors (RoHS compliant Halogen Free) Size 1206, 0805, 0603

General Purpose Relays Types K, R, N, and C

Model CS 64 Mini-DIN Cable and Adaptor

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series

ICON Server box installation manual Rev. 1.1

Electric Rotary Actuator - On/Off or programmable control actuator

Linkeo 19" freestanding cabinets

Semiconductor (AC) fuses

Selector Switch Type 01

Actuator-Sensor-Interface

Medium voltage products. Fuses

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

High Speed Infrared Emitting Diode, 870 nm, GaAlAs Double Hetero

Optocoupler, Phototransistor Output, with Base Connection

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PCMC063T- Power Choke Coil

Bulletin 150 SMC Flex Smart Motor Controller Specifications

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

Switchboard system. NorLine 800

How To Build A Low Voltage Capacitor Lvcp

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

Electronic overload relay EF19 and EF45

SQUARE D INDUSTRIAL CONTROL PRODUCTS

type V46, solenoid or pneumatic operated

EMERGENCY EGRESS LIGHTING POWER SUPPLY PART NO COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

SMS 4 / SMS 5 safety mat Product information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Protection from Short-circuit

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

IEC gg & am STANDARD LOW VOLTAGE FUSE

Transcription:

Description: A range of Class gg/gl square bodied industrial fuse links for a variety of applications. Packaging: MOQ: 3 (size 000 to 3) MOQ: 1 (size 4) Catalogue Symbol: Class of Operation: (amp)nhg(size)b-690 gg/gl Fuse Size: 000 to 4 Fuse Holders: Fuse Bases: SD*-D single-pole, TD*-D three-pole Fuse Rails-Vertical: BFR Fuse Switch Disconnectors-Vertical: BFD Fuse Switch Disconnectors-Horizontal: BFH * Select required size of fuse base Standards/Approvals: IEC 60269-1 and 2, DIN 43620 Part 1 and 3 Optional Microswitch: BVL50 and 170H0236 Technical Data: Sizes: 000 to 4 Rated Voltage: 690Vac* Rated Current: 2 to 800A Rated Breaking Capacity: 120kA** Operating Frequency: 45-62Hz Construction: - Steatite ceramic body - Corrosion resistant aluminium end plates - Corrosion resistant zinc plated plated screws - Silver-plated brass or copper contact blades Environmental 100% Recyclable (including packaging) RoHS Compliant Cadmium and lead free Features Low watts loss Reliable dual indicator system Metal gripping lugs * 160A size 00 rated at 660Vac ** 160A size 00 rated at 50kA 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 1 of 9 Data Sheet 720109

Dimensions (mm) Sizes 000 to 3 Size a1 a2 (max) a3 a4 b1 c1 c2 d1 e1 (max) e2 (max) e3 e4 f1 (max) 000 78.5±1.5 54 45±1.5 49±1.5 15 35±0.8 10 2±0.5 41 21 16 6 8 00 78.5±1.5 54 45±1.5 49±1.5 15 35±0.8 10 2±0.5 48 30 20 6 15 1 135±2.5 75 62±2.5 68±2.5 20 40±0.8 11 2.5±0.5 53 52 20 6 15 2 150±2.5 75 62±2.5 68±2.5 25 48±0.8 11 2.5±0.5 61 60 20 6 15 3 150±2.5 75 62±2.5 68±2.5 32 60±0.8 11 2.5±0.5 76 75 20 6 18 Size 4 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 2 of 9 Data Sheet 720109

Size 000, 2 to 63 Amps Size 000 Time-Current Characteristics Currents in Amps (A) Size 000 Technical Data I 2 t (A 2 s) 2NHG000B-690 2 3.5 8 4 4NHG000B-690 4 6 16 2 6NHG000B-690 6 14 25 2 10NHG000B-690 10 60 400 1.5 16NHG000B-690 16 240 1200 2.5 20NHG000B-690 20 500 2500 2.5 690 25NHG000B-690 25 920 4400 3.5 32NHG000B-690 32 1800 9600 3.5 35NHG000B-690 35 2400 12,700 4 40NHG000B-690 40 3300 15,000 4 50NHG000B-690 50 6100 26,500 5.5 63NHG000B-690 63 6500 30,500 5.5 0.118 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 3 of 9 Data Sheet 720109

Size 00, 50 to 160 Amps Size 00 Time-Current Characteristics Size 00 Technical Data I 2 t (A 2 s) 50NHG00B-690 50 5800 35,000 5 63NHG00B-690 63 5800 43,000 5 80NHG00B-690 80 690 11,000 54,500 7 100NHG00B-690 100 19,000 92,000 7.5 125NHG00B-690 125 27,500 105,000 9.5 160NHG00B-660* 160 660 40,500 135,000 13 0.182 * 160A: 50kA breaking capacity. 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 4 of 9 Data Sheet 720109

Size 1, 50 to 250 Amps Size 1 Time-Current Characteristics Size 1 Technical Data I 2 t (A 2 s) 50NHG1B-690 50 6350 26,500 6.4 63NHG1B-690 63 6800 36,000 5.6 80NHG1B-690 80 10,500 47,500 7.7 100NHG1B-690 100 22,000 105,000 8.2 125NHG1B-690 125 690 29,000 120,000 13 160NHG1B-690 160 71,000 240,000 13 200NHG1B-690 200 105,000 350,000 17 224NHG1B-690 224 120,000 430,000 19 250NHG1B-690 250 150,000 520,000 22 0.380 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 5 of 9 Data Sheet 720109

Size 2, 200 to 315 Amps Size 2 Time-Current Characteristics Size 2 Technical Data I 2 t (A 2 s) 200NHG2B-690 200 99,000 385,000 18 224NHG2B-690 224 130,000 485,000 20 690 250NHG2B-690 250 170,000 625,000 23 315NHG2B-690 315 295,000 760,000 32 0.620 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 6 of 9 Data Sheet 720109

Size 3, 250 to 500 Amps Size 3 Time-Current Characteristics Size 3 Technical Data I 2 t (A 2 s) 250NHG3B-690 250 160,000 715,000 21 315NHG3B-690 315 375,000 1,400,000 22 355NHG3B-690 355 400,000 1,650,000 25 690 400NHG3B-690 400 475,000 1,600,000 37 425NHG3B-690 425 630,000 1,700,000 35 500NHG3B-690 500 856,000 2,480,000 43 1.048 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 7 of 9 Data Sheet 720109

Size 4, 630 to 800 Amps Size 4 Time-Current Characteristics Size 4 Technical Data I 2 t (A 2 s) 630NHG4B-690 630 1,730,000 6,550,000 44 690 800NHG4B-690 800 3,300,000 11,000,000 61 2.5 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 8 of 9 Data Sheet 720109

Cut-off Characteristics Peak Cut-Off Current (ka) RMS Symetrical Prospective Current (ka) The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 22-08-12 BU-SB111443 Form NH 690V gg/gl Page 9 of 9 Data Sheet 720109