Beware; the Multiwire Branch Circuit

Similar documents
BRANCH CIRCUIT AND FEEDER REQUIREMENTS

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

NEC 2014 Code Changes

CHAPTER 2 EXAMPLES AND TABLES

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Arc Fault Circuit Interrupters Frequently Asked Questions

A. Shop Drawing submittals shall include, but not be limited to, the following:

Questions and Answers for Heating and A/C Contractors

Grounding & Bonding Why it is done And How to Install Properly

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Department of Labor and Industry Electrical Licensing

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Three-Phase Electric Power Distribution for Computer Data Centers

Conductor Sizing and the National Electrical Code

Generator Transfer Switch Model # HTS15-AUTO

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Services. Three Phase Service

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

Neutral Wire Facts and Mythology. White Paper #21

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

Corner-Grounded Delta (Grounded B Phase) Systems

ELECTRICAL INSPECTION BULLETIN (Effective )

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Electrical Design TABLE OF CONTENTS FOREWORD BASIC ELEMENTS OF ELECTRICITY... 2 Electricity works much like water Ohm s Law

Motor Protection Voltage Unbalance and Single-Phasing

Inverter / Charger Installation General Operations and AC and DC Connections

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

City of Riverside Building & Safety Division Phone: (951)

Parallel Circuits. Objectives After studying this chapter, you will be able to answer these questions: 1. How are electrical components connected

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Element D Services Electrical

Utility Distribution Systems

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Top Commercial / Residential Electrical Requirements *

IRRIGATION PUMPING Table of Contents - Section 900

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Commercial/Industrial Electricity

Section 3: Load Planning Bill Brown, P.E., Square D Engineering Services

County of Riverside Building and Safety Department

Siemens STEP 2000 Course Basics of Electrical Products

Definition AC Power Distribution

Liebert PPC Second Generation Power Distribution Cabinet

Server Technology Inc.

Fundamentals of Power

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Residential Electrical Inspection. Checklist

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Alternating Phase Power Distribution at the Data Center Rack PDU

Section B: Electricity

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

INSPECTION GUDELINES

The Service Entrance. Technical Terms Drip loop Insulator Meter Meter enclosure

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

The Different Types of AC Power Connectors in North America

INSTALLATION & SERVICE MANUAL. Display Panel

Presented by: The Electrical Association of Philadelphia 527 Plymouth Road, Suite 408 Plymouth Meeting, PA (610)

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Short Circuit Current Calculations

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

How Much Voltage Drop Is Acceptable?

Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment

Mike Holt s Illustrated Guide to. Rule , Articles 445, 700, 701, and 702. Based on the 2011 NEC

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary

2011 National Electrical Code Questions & Answers

Branch Circuit Calculations

BASIC NEC CODE RULES AND DESIGN PRACTICE

Description. Lesson Outcomes. Assumptions. Terminology. Electrician

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

AFCIs Come of Age. by Douglas Hansen

Rule Fast Track Analysis for National Life Insurance Co.

Voltage Drop (Single-Phase)

Requirements for Electrical Installations

Electrical. This section applies to the design and installation of building power distribution systems.

Electrical Practices for Construction Work

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Electrical Code Regulation

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Exploring the Necessity of the Hot Hipot Test

Power Quality for Information Technology System

THREE PHASE CIRCUITS

ELECTRIC CONVECTION BUILT-IN OVEN

Applications. Remote Display Mounting Kits

Extension Cord Safety Policy

Transcription:

eware; the Multiwire ranch ircuit The electrical industry has a formal ode, and it has unwritten rules-of-thumb, just as any other discipline involving construction. The ode changes every three years, and the changes are brought about by new technology and political pressure, but the rules-of-thumb are more subtle. onsequently, they are harder to change. The multiwire branch circuit has been the rule-of-thumb, and the "economy", of the electrical industry for too long. The ode has tried to address some of the safety issues raised by the use of multiwire branch circuits in residences. It requires a common trip of over-current protection for circuits sharing a neutral that are terminated on a common device, (such as a duplex receptacle). However, the danger to equipment in commercial and industrial applications remains. It is time for a change. The theory of the multiwire branch circuit is sound; a shared neutral conductor will only carry the imbalance of the loads on circuits supplied by different phases of a service. Therefore, if branch circuits are wired and maintained correctly, properly sized over-current protection is adequate for neutral conductors as well as ungrounded conductors. Three adjacent, 20 amp single-pole breakers in a three phase panel feed identical lighting loads, and share a neutral conductor. If the neutral connection at one of the T splices loses integrity, some of the loads will try to continue operating in a series configuration with the line-to-line voltage.

Issues of harmonic distortion and power quality have certainly made us more aware of the problems presented by the practice of sharing a neutral. Some manufacturers, and code panels have tried to address the problem by suggesting, or requiring an oversized neutral, but the danger of over-voltage to utilization equipment still exists. (grounds not shown) Unfortunately, it has been a common practice in the past, to wire receptacles with the same, shared neutral, multiwire branch circuit methods. The open indicated at the second T splice in the neutral, creates a situation in which two pieces of utilization equipment plugged into the outlets fed by breakers and would actually be connected in series with a 208 volt potential. This happens far too frequently, particularly with the use of powered base panels in partition walls for office cubicles. The partition walls have base sections that are usually hard wired to the facility electrical system, then plug into the adjacent sections to distribute power among the offices. Some of the partition manufacturers are abandoning the shared neutral method and providing separate neutrals with each ungrounded circuit conductor. This dramatically reduces the possibility of supplying an over-voltage to the equipment served within the office cubicles. The entire electrical industry should follow suit and provide a dedicated neutral with every circuit that distributes 120 volt, power. The high tech industry has lead the way in writing such requirements into their specifications. y requiring dedicated neutrals with every 120 volt circuit feeding receptacles, some project engineers have eliminated the chance of over-voltage damage to equipment caused by high resistance in the grounded conductor of multiwire branch circuits. In the interest of safety and protection of equipment, all 120 volt branch circuits that extend beyond a distribution panel board should be complete and independent of any other branch circuit. This means that all 120 volt circuits should have dedicated neutrals, and that shared neutrals should not be employed to feed receptacle circuits. In addition, these dedicated neutrals should be identified with the corresponding circuit number, at every splice. In this way, the electrician that comes to alter or extend and existing circuit, is less likely to tap the wrong neutral.

nother unwritten rule-of-thumb for the electrical industry that is widely practiced in the US, is that conductors brought into a 120/208 volt distribution panel are identified with the appropriate color; -phase circuit conductors are lack, -phase are Red, and -phase are lue. This helps keep the multiwire branch circuits grouped properly, (a neutral with each group of black, red, and blue ungrounded conductors). However... Distribution Panel N New receptacle being added (Grounds not shown) Existing receptacles fed by multi-wire branch circuit In the above drawing, an electrician is modifying an existing circuit by adding an outlet, and he s chosen the -phase circuit. In order to implement this addition safely and without risk to utilization equipment fed by the other two circuits, he must turn off all three circuits. Otherwise, when he removes the wire nut from the neutrals to tie in the additional neutral, a momentary interruption in neutral continuity between the other circuits and the panel could cause over-voltage at the receptacles. In another hypothetical situation, one of the three breakers fails, and an electrician moves the circuit conductor to a spare breaker that doesn t happen to be on the correct phase of the service. Now there is a possibility of over-loading the neutral without tripping any over-current devices. In fact, when the loads on the three circuits aren t balanced, and they have different inductive characteristics, the voltages are no longer 120 electrical degrees apart, and the neutral can be subjected to overload conditions even if the system is correctly connected and maintained. It s Time for a hange! D. lements Oregon electrical inspector s certificate #5217EI

1. 1. 3,5 3,5 5 Dedicated neutrals for receptacle circuits... 5 P 2 6 no more M's! panel P P 2,4,6 4,6 4,6 6 The time has come for electricians and electrical engineers to step up to the safety plate, and chose to use a slightly more expensive wiring method. Sure we save a little copper and we have a little less pipe fill using multi-wire branch circuits, but the subtle problems, and the huge potential for damage to utilization equipment, should be reason enough to ban their use. If the engineers specify dedicated neutrals, and electricians resolve to pull a neutral with every 120 volt circuit that feeds convenience outlets and receptacles, we ll save ourselves and our customers, a lot of grief in the future. M It took the electrical industry several generations to recognize the safety issue of separate ground and neutral conductors to ranges and dryers. Let s not make the same mistake with Multiwire ranch ircuits. There are already, far too many M installations in existence. Let s stop installing them now... and hopefully, the National Electrical ode will follow with revisions that support this choice for quality, rather than economy. Take this significant step... and improved power quality will surely follow!

Multiwire ranch ircuits and the 1999 National Electrical ode rticle 100 Definitions page 70 19 ranch ircuit, Multiwire. branch circuit that consists of two or more ungrounded conductors that have a potential between them, and a grounded conductor that has equal potential difference between it and each ungrounded conductor of the circuit and that is connected to the neutral or grounded conductor of the system. rticle 210-4. Multiwire ranch ircuits. page 70 37 (a) General. ranch circuits recognized by this article shall be permitted as multiwire branch circuits. multiwire branch circuit shall be permitted to be considered as multiple circuits. ll conductors shall originate from the same panelboard. FPN: 3-phase, 4-wire, wye-connected power system used to supply power to nonlinear loads may necessitate that the power system design allow for the possibility of high harmonic neutral currents. (b) Dwelling Units. In a dwelling unit, a multiwire branch circuit supplying more than one device or equipment on the same yoke shall be provided with a means to disconnect simultaneously all ungrounded conductors at the panelboard where the branch circuit originated. page 70 38 (c) Line-to-Neutral Loads. Multiwire branch circuits shall supply only line-to-neutral loads. Exception No. 1: multiwire branch circuit that supplies only one utilization equipment. Exception No. 2: Where all ungrounded conductors of the multiwire branch circuit are opened simultaneously by the branch-circuit overcurrent device. (d) Identification of the Ungrounded onductors. Where more than one nominal voltage system exists in a building, each ungrounded conductor of a multiwire branch circuit, where accessible, shall be identified by phase and system. This means of identification shall be permitted to be by separate color coding, marking tape, tagging, or other approved means and shall be permanently posted at each branch-circuit panelboard. Note from D, (the author of this article); nother unwritten rule-of-thumb commonly practiced in the electrical industry is that 120/208 volt circuits utilize black/red/blue w/white neutrals, and 277/480 volt circuits use brown/orange/yellow w/grey neutrals.

Table 310-15(b)(2)(a). djustment factors for More than Three urrent-arrying onductors in a Raceway of able. page 70 124 Number of urrent-arrying onductors 4-6 7-9 10-20 21-30 31-40 41 and above Percent of Values in Tables 310-16 through 310-19 as djusted for mbient Temperature if Necessary 80 70 50 45 40 35 rticle 310-15(b)(4). Neutral onductor. page 70 124 (a) neutral conductor that carries only the unbalanced current from other conductors of the same circuit shall not be required to be counted when applying the provisions of Section 310-15(b)(2)(a). (b) In a 3-wire circuit consisting of two phase wires and the neutral of a 4-wire, 3-phase wye-connected system, a common conductor carries approximately the same current as the line-to-neutral load currents of the other conductors and shall be counted when applying the provisions of Section 310-15(b)(2)(a). (c) On a 4-wire, 3-phase wye circuit where the major portion of the load consists of nonlinear loads, harmonic currents are present in the neutral conductor; the neutral shall therefore be considered a current-carrying conductor. (More notes from D) These excerpts from the 1999 NE relate to multiwire branch circuits, and clearly indicate that the NE recognizes the use of this wiring method. The following page describes a hypothetical situation that encourages electricians and engineers to use Ms. This situation occurs frequently in real-world construction, and the significant difference in the cost of installation is usually the deciding factor.

room in an office building requires 6 120 volt, 20 amp circuits for computer equipment. 120/208 volt, 3-phase, 4-wire, distribution panelboard is located in an electrical closet about 80 feet down the hall. Here s a few questions about the installation: 1. What size raceway(s) would be required for the 'home run' from the junction box? 2. What size wire would be required in each scenario? 3. Which method would you use; a. dedicated neutrals b. Multiwire ranch ircuit 2 2,4 2,4,6 3,5 5 2,4,6 2,4,6 1 1,3 2,4,6 4,6 6 Here's the unfortunate answers; 1. The M method could utilize a 3/4" raceway, while the dedicated neutral method would require a 1 conduit. 2. The M method requires a maximum of eight current-carrying conductors, while the dedicated neutral method requires 12. ccording to Table 310-15(b)(2)(a), the M method could use #12 conductors, while the dedicated neutrals method would require #10s! Economics dictate that the electrician use Ms, but it's a short-sighted choice! The loads are better served and protected by the dedicated neutral method. Other countries of the world do not use Ms... It's Time for a hange... Quality and Safety, not Economy!