Measuring Insulation Resistance of Capacitors



Similar documents
Measurement of Capacitance

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

Op-Amp Simulation EE/CS 5720/6720. Read Chapter 5 in Johns & Martin before you begin this assignment.

Lab 7: Operational Amplifiers Part I

Understanding Power Impedance Supply for Optimum Decoupling

Lab E1: Introduction to Circuits

Reading: HH Sections , (pgs , )

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Measuring Electric Phenomena: the Ammeter and Voltmeter

Electrical Safety Tester Verification

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

OPERATIONAL AMPLIFIERS

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

BJT Amplifier Circuits

Pressure Transducer to ADC Application

BJT Amplifier Circuits

Bipolar Transistor Amplifiers

Operational Amplifier - IC 741

Application Note. So You Need to Measure Some Inductors?

Building the AMP Amplifier

Lab 3 - DC Circuits and Ohm s Law

How To Calculate The Power Gain Of An Opamp

Lock - in Amplifier and Applications

User Guide. Model Insulation Tester / Megohmmeter

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

High Voltage Power Supplies for Analytical Instrumentation

MAS.836 HOW TO BIAS AN OP-AMP

An Overview of Practical Capacitance Bridge Functioning. by Paul Moses

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

Transistor Amplifiers

LLM 6 th Edition Low Level Measurements Handbook Precision DC Current, Voltage, and Resistance Measurements

Lecture - 4 Diode Rectifier Circuits

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Digital to Analog Converter. Raghu Tumati

Application Guide Film Capacitors

11: AUDIO AMPLIFIER I. INTRODUCTION

css Custom Silicon Solutions, Inc.

Tutorial on Safety Standard Compliance For Hipot Testing

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER

Critical thin-film processes such as deposition and etching take place in a vacuum

= V peak 2 = 0.707V peak

Measuring Biased Inductors with the GenRad Digibridge

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

Insulation resistance testing. A complete solution for every person.

OPERATIONAL AMPLIFIERS. o/p

Op Amp Circuit Collection

A Practical Guide to Dielectric Testing

Objective. To design and simulate a cascode amplifier circuit using bipolar transistors.

Chapter 10. RC Circuits ISU EE. C.Y. Lee

Constant Voltage and Constant Current Controller for Adaptors and Battery Chargers

Conversion Between Analog and Digital Signals

Programmable-Gain Transimpedance Amplifiers Maximize Dynamic Range in Spectroscopy Systems

ARRL Morse Code Oscillator, How It Works By: Mark Spencer, WA8SME

RLC Resonant Circuits

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

SELECTION GUIDE. Nominal Input

Since any real component also has loss due to the resistive component, the average power dissipated is 2 2R

Experiment 4 ~ Resistors in Series & Parallel

Loop Calibration and Maintenance

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Basic Op Amp Circuits

Frequency Response of Filters

Scaling and Biasing Analog Signals

Section 3. Sensor to ADC Design Example

The Time Constant of an RC Circuit

DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

Inductors in AC Circuits

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

LC103 ReZolver In-Circuit Capacitor & Inductor Analyzer

Diodes have an arrow showing the direction of the flow.

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

Measuring Impedance and Frequency Response of Guitar Pickups

HT9170 DTMF Receiver. Features. General Description. Selection Table

User's Guide. True RMS Industrial Multimeter

Alphasense Application Note AAN DESIGNING A POTENTIOSTATIC CIRCUIT

Technical Note #3. Error Amplifier Design and Applications. Introduction

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Physics 120 Lab 6: Field Effect Transistors - Ohmic region

AC : MEASUREMENT OF OP-AMP PARAMETERS USING VEC- TOR SIGNAL ANALYZERS IN UNDERGRADUATE LINEAR CIRCUITS LABORATORY

Precision Diode Rectifiers

Fundamentals of Signature Analysis

Common Emitter BJT Amplifier Design Current Mirror Design

Common-Emitter Amplifier

A Collection of Differential to Single-Ended Signal Conditioning Circuits for Use with the LTC2400, a 24-Bit No Latency Σ ADC in an SO-8

Electrical Resonance

RC Circuits and The Oscilloscope Physics Lab X

Lecture 24: Oscillators. Clapp Oscillator. VFO Startup

Chapter 12: The Operational Amplifier

LLM 6 th Edition Low Level Measurements Handbook Precision DC Current, Voltage, and Resistance Measurements

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Application Note 142 August New Linear Regulators Solve Old Problems AN142-1

Homework Assignment 03

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

Electricity and Magnetism, Georgia, GEOSTM (Georgian National Agency for Standards and Metrology)

Apprentice Telecommunications Technician Test (CTT) Study Guide

Transcription:

Application Note Measuring Insulation Resistance of Capacitors A common use of high resistance measuring instruments (often called megohmmeters or insulation resistance testers) is measuring the insulation resistance of capacitors. Such tests are useful to quality engineers in the production of capacitive components, by design engineers to determine suitability for a particular application or at incoming inspection. By the proper application of a megohmmeter type instrument a capacitor's dielectric material can be tested and evaluated in two ways. First, the DC value of its impedance (resistance) can be determined. This is an important parameter in some types of capacitors such as ceramic or film, where a high value of insulation resistance is a primary reason in choosing them for an application. It may be that a design engineer has determined that his circuit will not work well below a certain value of insulation resistance. In addition, the DC resistance of a capacitor tells something about its quality. Wide variations from unit to unit or consistently low values may indicate a quality problem. Second, the measurement of the capacitor's insulation resistance with high voltage is an excellent way of detecting flaws in the dielectric material, which might not otherwise make themselves known until long after installation in the user's equipment. Ceramic dielectrics are subject to cracking (as are all ceramic materials), and often these cracks will not be noticed at normal voltages. However, with the application of 500 or 000 volts, breakdown along the crack edges often occurs resulting in an abnormally low value for DC resistance. Why are Capacitors hard to Test? When a capacitor with high insulation resistance is attached to the measurement terminals of the typical high resistance meter, the user may notice some very strange behavior of the instrument. Resistance readings will fluctuate widely in continuous mode, and never settle down. If a pure resistor of similar value is substituted for the capacitor, the readings usually settle down and the instrument measures the device perfectly. This situation can be exhibited on most megohmmeters, whether the instrument has the older analog display or the newer digital display. What is interesting is that, although the variation of readings may be greater on the analog meter, it may be less evident. This is because the resolution on these older instruments is less than those designed today. To the casual user the analog readout that covers one or two decades from zero to full scale will not appear to waiver much for values changing by 2:. On a digital display even though the readout may be more representative of the actual results in many cases it can be annoying and make readings unreliable to difficult. This phenomenon is caused by the way that megohmmeters measure resistance.

What Does That Look Like? Figure is a standard way of building an operational amplifier gain stage used in the detector circuit of many types of instruments. The input resistor (Rin) is actually the unknown (DUT). The feedback resistor () is a range resistor selected by a range switch or software when auto ranging is employed, to match the level of current flowing into the detector. This range resistor is very stable and its value must be known precisely or measured during the calibration of the instrument. The voltage out of the detector then depends upon the input voltage and the value of Rin (the unknown). The value of is known and accuracy verified when the instrument is calibrated, so Rin is the only variable. The best way to understand all this is to assume a set of test conditions, with the instrument set to its more sensitive range (na full-scale) and a feedback resistor of 2GΩ (2x0 9 Ω). If the unknown value was 200GΩ (2x0 Ω) and 00 volts applied to it, the current flowing would be 0.5nA or half scale. This results in an output voltage of V since the gain of the detector is /Rin 2GΩ/200GΩ 0.0. Rin - + Vout Rin Figure : Typical Op-Amp Circuit If the unknown is a capacitor, however, things get a little more complex. C - + Vout Figure 2: Capacitor Equivalent Circuit

A Real Capacitor A "real" capacitor consists of an ideal capacitor in parallel with its insulation resistance. This ideal capacitor has infinite resistance at DC. As frequency goes up, however, its reactance decreases according to: X C 2 π fc where f is the frequency in hertz, and C is the capacitance in farads. Notice that we use the symbol Xc for the reactance of the pure capacitor, to distinguish from its insulation resistance, R. In this example we'll consider a ceramic capacitor of 2.2uf (2.2x0-6 farads) with a typical minimum insulation resistance of 2GΩ. If a capacitor is tested at 200V and measures a dielectric leakage current of 0nA the insulation resistance must be 20GΩ. For 0nA the instrument would be on the 00nA full-scale range with a feedback resistor of 20MΩ. In this case the gain of the detector is 20MΩ/20GΩ, or.00. The output voltage would then be [(.00) (200V)], or 200mV. This all assumes DC. As soon as we consider AC, things change. At a frequency of Hz, the "ideal" capacitor in this unit will have a reactance, Xc, equal to: 6 6.28()(2.2x0 ) 7.2x0 The AC gain of the detector would be: 20 Mohms 7.2x0 270 The source of Hz voltage on the input could be any one of several things. It could be room noise picked up by the meter leads, or small fluctuations in the instrument power supply. Even moving the leads (as on an automatic handler) can induce low frequency AC on them. Generally, the induced AC voltage will be small perhaps mv, but the detector would multiply this by 270 to give an output of 270mV. This is higher than the "true" reading of 200mV. The noise from this mv source can cause the result to vary by 35%. So What Do You Do? This situation could be improved by shielding the device under test (DUT) and the test leads from the AC noise. Indeed, at high values of resistance (above GΩ) low noise shielded cables are highly recommended. The real solution to the problem of capacitor testing comes from remembering the cause - high AC gain. If we can reduce the AC gain, we can eliminate the problem.

AC Gain Compensation Recall that the AC gain is /Xc. If we were to add a compensation resistor, Rc of MΩ in series with the DUT, the AC gain would become: Rc + Xc 20 Mohms 8.65 Mohm + 7.2 x 0 This is a lot better than 270! With the same mv of noise in, we get only 8.65mV out compared to the "true" signal of 200mV. The series resistor, Rc, has reduced the AC gain to 9.35% of the DC gain, a tolerable level. DC Errors At this point, one might worry that, although we've solved the instability problem, we've introduced an error term of MΩ. We have! But, so what? Remember, we're in the business of trying to measure 2GΩ versus an induced error of MΩ (.00GΩ). The error is.05%. At lower values of DC resistance, a MΩ resistor may be significant, so a smaller compensation resistor should be used. Capacitors with a dielectric leakage current greater than 0uA are simply too "leaky" to exhibit the fluctuations of readings in the first place. Lastly, the addition of series Rc will increase the charge time somewhat. This is unavoidable, but in most cases will be inconsequential. Procedure Using 865 Megohmmeter/IR Tester The 865 is supplied with two quieting resistors that can be placed in series with the DUT when measuring low leakage capacitors. 865 Megohmmeter IR Tester! QuadTech SHIELDED LEAD SET HIGH VOLTAGE DISPLAY 33.620MΩ Voltage 00 Mode AUTO RESISTANCE Range ua <A> SELECT ENTRY 2 3 MENU 5 6 CNCL 7 8 9 ENTER - 0. TEST STOP START P/N 630020 0 + - G 00kΩ LO RANGE DUT 865-5 Shielded Lead Set Sheathed Banana Plugs Quieting Resistor Figure 3: 865 Megohmmeter with Quieting Resistor

Conclusion To determine the proper adapter to use, simply measure several devices on the 865 with Auto Range selected. Generally, no resistor is required for the 00uA and ma ranges. This can be confirmed by looking for instability in the readings over a measure time of, say, ten seconds. Note that, during this time, the readings on a non-charged capacitor will change as the DUT charges up. But the reading should increase steadily, not fluctuate up and down. If the readings seem to fluctuate, a quieting resistor may be required. Refer to Table to help select the proper resistor for the measurement range being used. There may be cases (hard to predict) where a higher value compensating-resistor is required on the low current range (na). In general, the two resistors supplied with the 865 unit should suffice. The Current Range is calculated by dividing the Test Voltage by the Resistance Limit. I RANGE V TEST / R LIMIT. Table : Choosing the Correct Quieting Resistor Current Range Quieting Resistor (QR) Value na HI RANGE MΩ 0nA HI RANGE MΩ 00nA LO RANGE 00kΩ µa LO RANGE 00kΩ 0µA LO RANGE 00kΩ 00µA Not Required N/A ma Not Required N/A For complete product specifications on the 865 Megohmmeter/IR Tester or any of IET Labs products, visit us at www.ietlabs.com. Do you have an application specific testing need? Call us at -800-899-838 or email your questions to sales@ietlabs.com and we ll work with you on a custom solution. The information presented here is subject to change and is intended for general information only IET Labs, Incorporated -800-899-838 - Printed in U.S.A. June 2003